Continental Indoor Fireplace BCDV42N User Manual

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.  
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS  
DIRECT VENT MILLIVOLT SYSTEM  
INSTALLATION AND OPERATION INSTRUCTIONS FOR  
VENTED GAS FIREPLACE HEATER  
NATURAL GAS MODEL BCDV42N  
PROPANE GAS MODEL BCDV42P  
CERTIFIED FOR CANADAAND UNITED STATES USINGANSI / CSAMETHODS  
WARNING: If the information in these instructions is not followed exactly, a fire or  
explosion may result causing property damage, personal injury or death.  
FOR YOUR SAFETY  
Do not store or use gasoline or other flammable vapours and liquids in the vicinity  
of this or any other appliance.  
WHAT TO DO IF YOU SMELL GAS:  
• Do not try to light any appliance.  
• Do not touch any electrical switch.  
• Do not use any phone in your build-  
ing.  
• Immediately call your gas supplier from  
a neighbour's phone. Follow the gas  
supplier's instructions.  
• If you cannot reach your gas supplier,  
call the fire department.  
Installation and service must be performed by a qualified installer, service agency  
or the gas supplier.  
R-2000  
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized  
ISO 9001 : 2000 Quality Assurance Certificate.  
CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen  
who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.  
Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure  
that you, the customer, receives the quality product that you expect from WOLF STEEL Ltd..  
CONTINENTAL GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY  
The following materials and workmanship in your new CONTINENTAL gas fireplace are  
warranted against defects for as long as you own the fireplace. This covers: combustion  
chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass  
(thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled compo-  
nents and aluminium extrusion trims.  
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,  
thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are  
covered and WOLF STEEL LTD. will provide replacement parts free of charge during the  
first year of the limited warranty.  
Any labour related to warranty repair is not covered.  
CONDITIONS AND LIMITATIONS  
WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears  
on the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an authorized CONTINENTAL dealer and is subject to the following  
conditions and limitations:  
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.  
The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with  
the product and all local and national building and fire codes.  
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify  
this warranty.  
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain  
enamel parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.  
WOLF STEEL Ltd. warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years WOLF STEEL  
Ltd. will replace or repair the defective parts at our option free of charge. From 10 years to life, WOLF STEEL LTD. will provide replacement burners at 50% of the current retail price.  
In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated  
in accordance with the operation instructions and under normal conditions.  
After the first year, with respect to this President's Limited Lifetime Warranty, WOLF STEEL LTD. may, at its discretion, fully discharge all obligations with respect to this warranty  
by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).  
WOLF STEEL Ltd. will not be responsible for installation, labour, or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered  
by this warranty.  
Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, WOLF STEEL’S responsibility under this warranty is defined as above and it shall not in  
any event extend to any incidental, consequential or indirect damages.  
This warranty defines the obligations and liability of WOLF STEEL Ltd. with respect to the CONTINENTAL gas fireplace and any other warranties expressed or implied with respect  
to this product, its components or accessories are excluded.  
WOLF STEEL Ltd. neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. WOLF STEEL Ltd. will not  
be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation,  
excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes  
dryers, etc.  
Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging  
chemicals or cleaners will not be the responsibility of WOLF STEEL Ltd.  
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration  
card must be returned within fourteen days to register the warranty.  
WOLF STEEL Ltd. reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.  
ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. CONTINENTAL® IS A REGISTERED  
TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Maximum inlet gas pressure is 7 inches water column for  
natural gas and 13 inches water column for propane. Mani-  
fold pressure under flow conditions is 3.5 inches water col-  
umn for natural gas and 10 inches water column for propane.  
GENERAL INSTRUCTIONS  
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV-  
ICED BYAQUALIFIED INSTALLER to conform with local codes.  
In absence of local codes, install the BCDV42 to the current  
National Fuel Gas Code, ANSI Z223.1, or the current  
CAN/CGA B149, Installation Codes.  
This fireplace is approved for bathroom, bedroom and bed-  
sitting room installations and is suitable for mobile home  
installation.  
Installation practices vary from region to region and it is  
important to know the specifics that apply to your area,  
No external electricity (110 volts or 24 volts) is re-  
quired for the gas system operation.  
for example: in Massachusetts State:  
Expansion / contraction noises during heating up  
and cooling down cycles are normal and are to be  
expected.  
• The fireplace damper must be removed or welded in the open  
position prior to installation of a fireplace insert or gas log.  
• The appliance off valve must be a “T” handle gas cock.  
• The flexible connector must not be longer than 36 inches.  
CARE OF GLASS, AND PLATED PARTS  
• The appliance is not approved for installation in a bedroom or  
bathroom unless the unit is a direct vent sealed combustion  
product.  
Do not use abrasive cleaners to clean plated parts. Buff lightly  
with a clean dry cloth. The BCDV42 is factory equipped with  
tempered glass. The glass thickness is 3/16". Use only re-  
placement glass available from your Continental dealer. DO  
NOT SUBSTITUTE MATERIALS. Clean the glass after the first  
10 hours of operation with a recommended gas fireplace  
glass cleaner. Thereafter clean as required. DO NOT CLEAN  
GLASS WHEN HOT! If the glass is not kept clean permanent  
• WARNING: This product must be installed by a licensed plumber  
or gas fitter when installed within the commonwealth of Mas  
sachusetts.  
Mobile home installation must conform with local codes or in the  
absence of local codes, install to the current standard for gas  
equipped mobile housing CAN/CSA ZA240 MH Series in Canada  
or the Manufactured Home Construction and Safety Standard,  
Title 24 CFR, Part 3280, or the Fire Safety Criteria for Manufac-  
tured Home Installations, Sites and Communities Standard ANSI/  
NFPA 501A in the United States.  
discolouration and / or blemishes may result.  
Use only accessories designed for and listed with  
your specific fireplace.  
Provide adequate ventilation air. Provide adequate ac-  
cessibility clearance for servicing and operating the  
fireplace. Never obstruct the front opening of the fire-  
place.  
The fireplace and its individual shutoff valve must be discon-  
nected from the gas supply piping system during any pressure  
testing of that system at test pressures in excess of 1/2 psig  
(3.5 kPa). The fireplace must be isolated from the gas supply  
piping system by closing its individual manual shutoff valve  
during any pressure testing of the gas supply piping system at  
test pressures equal to or less than 1/2 psig (3.5 kPa).  
For safe and proper operation of the fireplace follow the  
venting instruction exactly.  
Deviation from the minimum vertical vent length can  
create difficulty in burner start-up and/or carboning.  
When the fireplace is installed directly on carpeting, vinyl tile  
or other combustible material other than wood flooring, the  
fireplace shall be installed on a metal or wood panel extend-  
ing the full width and depth.  
Provide a means for visually checking the vent con-  
nection to the fireplace after the fireplace is installed.  
In order to avoid the possibility of exposed insulation or  
vapour barrier coming in contact with the fireplace body,  
it is recommended that the walls of the fireplace enclo-  
sure be 'finished', (i.e. drywall/sheetrock) as would any  
other outside wall of the home. This will ensure that  
clearance to combustibles is maintained within the cav-  
ity.  
If the optional fan or blower is installed, the junction box must  
be electrically connected and grounded in accordance with  
local codes. In the absence of local codes, use the current  
CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the  
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United  
States.  
GENERAL INFORMATION  
Vent lengths that pass through unheated spaces (at-  
tics, garages, crawl spaces) should be insulated with  
the insulation wrapped in a protective sleeve to mini-  
mize condensation.  
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN  
TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!  
Maximum input is 28,500 BTU/hr for natural gas and 24,000  
BTU/hr for propane. When the fireplace is installed at elevations  
above 4,500ft, and in the absence of specific recommendations  
from the local authority having jurisdiction, the certified high alti-  
tude input rating shall be reduced at the rate of 4% for each  
additional 1,000ft.  
Objects placed in front of the fireplace must be kept a  
minimum of 48" away from the front face of the unit.  
Maximum output for natural gas is 19,500 BTU/hr at an effi-  
ciency of 68.5% with the fan on, and 16,000 BTU/hr for pro-  
pane at an efficiency of 67% with the fan on. The maximum  
A.F.U.E. (annual fuel utilization efficiency) rating is 64% for  
natural gas and 61.5% for propane.  
Minimum inlet gas supply pressure is 4.5 inches water col-  
umn for natural gas and 11 inches water column for propane.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
FIGURE 1  
VENTING  
Eight (8") inches is the minimum bend radius allowed  
for the 8" diameter flexible liner.  
VENTING LENGTHS  
Use only Wolf Steel or Simpson Dura-Vent Model DV-GS  
venting components. Minimum and maximum vent lengths,  
for both horizontal and vertical installations, and air termi-  
nal locations for either system are set out in this manual  
and must be adhered to. For Simpson Dura-Vent, follow  
the installation procedure provided with the venting com-  
ponents.  
For optimum performance it is recommended that all  
horizontal runs have a 1 inch rise per foot when using  
Continental flexible vent components.  
A terminal shall not terminate directly above a sidewalk  
or paved driveway which is located between two sin-  
gle family dwellings and serves both dwellings. Local  
codes or regulations may require different clearances.  
When using Wolf Steel venting components, use only ap-  
proved Wolf Steel rigid / flexible components with the fol-  
lowing termination kits: WALL TERMINAL KIT GD422, or  
1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD410, 8/12 TO  
12/12 ROOF TERMINAL KIT GD411, FLAT ROOF TERMI-  
NAL KIT GD412 or PERISCOPE KIT GD401 (for wall pen-  
etration below grade). With flexible venting, in conjunction  
with the various terminations, use either the 5 foot vent kit  
GD420 or the 10 foot vent kit GD430.  
Do not allow the inside liner to bunch up on horizontal or  
vertical runs and elbows. Keep it pulled tight. A 1¼" air  
gap all around between the inner liner and outer liner is  
required for safe operation. Use a firestop when pen-  
etrating interior walls, floor or ceiling.  
Minimum clearance to combustible con-  
struction from fireplace and vent sur-  
faces:  
It is recommended to attach the Wolf Steel 45º rigid adap-  
tor directly to the unit when terminating horizontally off  
the back of the unit. This must be done before attaching  
the desired vent system. Once this transition has been  
made, venting systems must not be combined.  
sides, back, bottom and top of the unit 0 inch  
recessed depth  
top, sides and bottom of the vent pipe 1 inch  
vent heat shield 1 inch  
22 inches  
Horizontal runs may have a 0 inch rise per foot in all  
cases using SIMPSON DURA-VENT or CONTINENTAL  
RIGID OR FLEXIBLE venting components when vent-  
ing as illustrated in Figures 3, and 4.  
These vent kits allow for either horizontal or vertical venting  
of the fireplace. FIGURES 3 & 5. The maximum allowable  
horizontal run is 20 feet. The maximum allowable vertical  
vent length is 40 feet. The maximum number of 5" vent  
connections is two horizontally or three vertically (exclud-  
ing the fireplace and the air terminal connections) when  
using aluminum flexible venting.  
Only a clearance to combustibles of 1" all around the  
vent pipe is required.  
For optimum flame appearance and fireplace perform-  
ance, keep the vent length and number of elbows to a  
minimum.  
The air terminal must remain unobstructed at all times.  
Examine the air terminal at least once a year to verify  
that it is unobstructed and undamaged.  
Purge all gas lines with the glass door of the fireplace  
removed. Assure that a continuous gas flow is at the  
burner before re-installing the door.  
Under extreme vent configurations, allow several minutes  
(5-15) for the flame to stabilize after ignition.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
AIR TERMINAL INSTALLATIONS  
FIGURE 2  
INSTALLATIONS  
CANADIAN  
12 INCHES  
12 INCHES  
U.S.A.  
12 INCHES  
9 INCHES  
A
B
C
Clearance above grade, veranda porch, deck or balcony.  
Clearance to windows or doors that open.  
Clearance to permanently closed windows.  
12 INCHES*  
12 INCHES*  
Vertical clearance to ventilated soffit located above the terminal within  
a horizontal distance of 2 feet from the centerline of the terminal.  
D
32 INCHES**  
32 INCHES**  
0 INCHES  
32 INCHES**  
32 INCHES**  
0 INCHES  
E
F
Clearance to unventilated soffit.  
Clearance to an outside corner wall.  
Clearance to an inside non-combustible corner wall or protruding  
non-combustible obstructions (chimney, etc.).  
0 INCHES***  
2 INCHES***  
0 INCHES***  
2 INCHES***  
G
Clearance to an inside combustible corner wall or protruding com-  
bustible obstructions ( vent chase, etc.).  
Clearance to each side of the centerline extended above the meter  
/ regulator assembly to a maximum vertical distance of 15ft.  
H
I
3 FEET  
3 FEET  
3 FEET****  
3 FEET****  
9 INCHES  
3 FEET†  
Clearance to a service regulator vent outlet.  
Clearance to a non-mechanical air supply inlet to the building or a  
combustion air inlet to any other appliance.  
J
K
L
12 INCHES  
6 FEET  
Clearance to a mechanical air supply inlet.  
Clearance above a paved sidewalk or paved driveway located on  
public property unless fitted with a heat shield kit GD-301.  
7 FEET‡  
7 FEET****  
M
N
O
Clearance under a veranda, porch, deck or balcony.**  
Clearance above the roof.  
32 INCHES†† 32 INCHES****  
16 INCHES  
2 FEET†*  
16 INCHES  
2 FEET†*  
Clearance from an adjacent wall including neighbouring buildings.  
*
**  
Recommended to prevent condensation on windows and thermal breakage  
Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of  
18". It is recommended to maximize the distance to vinyl clad soffits.  
*** The periscope GD-401 requires a minimum 18 inches clearance from an inside corner.  
**** This is a recommended distance. For additional requirements check local codes.  
Three feet above if within 10 feet horizontally.  
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family  
dwellings and serves both dwellings.  
†† Permitted only if the veranda, porch or deck is fully open on a minimum of two sides beneath the floor.  
†* Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
TYPICAL VENT INSTALLATIONS  
NOTE:  
When terminating vertically, the restrictor  
plate W500-0205 must be installed. Refer to  
Restricting Vertical Vents.  
FIGURES3a-c  
SPECIAL VENT INSTALLATIONS  
PERISCOPE TERMINATION  
Use the GD401 periscope kit to locate the air termination  
above grade. The periscope must be installed so that when  
final grading is completed, the bottom air slot is located a  
minimum of 12 inches above grade. The maximum allow-  
able vent length depends on the fireplace, as illustrated.  
FIGURE 4  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
VENTING APPLICATION FLOW CHART  
VERTICAL  
TERMINATION  
HORIZONTAL  
TERMINATION  
v e r t i c a l  
vertical rise  
vertical rise  
is equal to  
or greater  
than the  
horizontal  
run  
vertical rise  
is equal to  
or greater  
than the  
horizontal  
run  
rise is less  
than hori-  
zontal run  
is less than  
horizontal  
run  
horizontal  
run + verti-  
cal rise to  
maximum  
of 40 feet  
horizontal  
run + verti-  
cal rise to  
maximum of  
24.75 feet  
horizontal  
run + verti-  
cal rise to  
maximum  
of 40 feet  
horizontal  
run + verti-  
cal rise to  
maximum  
of 40 feet  
4.2 times  
the vertical  
rise equal to  
or greater  
3 times the  
vertical rise  
equal to or  
g r e a t e r  
than  
the  
than  
the  
horizontal  
run  
horizontal  
run  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
DEFINITIONS  
ELBOW VENT LENGTH VALUES  
for the following symbols used in the venting calcula-  
tions and examples are:  
feet  
0.03  
inches  
0.5  
1°  
> - greater than  
> - equal to or greater than  
< - less than  
15°  
30°  
45°*  
90°*  
0.45  
0.9  
1.35  
2.7  
6.0  
11.0  
16.0  
32.0  
< - equal to or less than  
HT - total of both horizontal vent lengths (HR) and off-  
sets (HO) in feet  
HR - combined horizontal vent lengths in feet  
HO - offset factor: .03(total degrees of offset - 135°*) in  
feet  
* the first 45º and 90° offset has a zero value and is  
shown in the formula as -45° and -90º respectively  
or -135º when combined.  
VT - combined vertical vent lengths in feet  
HORIZONTAL TERMINATION  
For vent configurations requiring more than one 45º and  
90° elbow, the following formulas apply:  
when (HT) < (VT)  
Simple venting configuration (only one 45º and 90° elbow)  
Formula 1: HT < VT  
90°  
Formula 2: HT + VT < 40 feet  
Example 1:  
90°  
H2  
FIGURE 5  
V1  
FIGURE 6  
45º  
45º  
H1  
90°  
V1 = 8ft  
VT  
=
V1 = 8 ft  
REQUIRED  
H1 = 2.5 ft  
H2 = 2ft  
VERTICAL  
RISEINFEET  
(VT)  
HR = H1 + H2 = 2.5 + 2 = 4.5 ft  
HO = .03(one 45º elbow + two 90º elbows - 135º)  
=0.3(225-135º) = 2.7ft  
HT = HR + HO = 4.5 + 2.7 = 7.2 ft  
CALCULATED HORIZONTAL VENT RUN  
PLUS OFFSETS IN FEET (HT)  
HT + VT = 7.2 +8 =15.2ft  
The shaded area within the lines represents acceptable  
values for HT and VT .  
Formula 1: HT < VT  
7.2 < 8  
Formula 2: HT + VT < 40 feet  
15.2 < 40  
Since both formulas are met, this vent configuration is ac-  
ceptable.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
HORIZONTAL TERMINATION  
when (HT) > (VT)  
Example 2:  
Simple venting configuration (only one 45º and 90° elbow)  
90°  
See graph to determine the re-  
FIGURE 7  
90°  
FIGURE 8  
quired vertical rise VT for the re-  
H4  
H3  
H2  
quired horizontal run HT.  
45°  
V2  
H1  
90°  
V1  
V1  
V2  
VT  
= 4ft  
= 1.5 ft  
= V1 + V2 = 4 ft + 1.5 ft = 5.5 ft  
REQUIRED  
VERTICAL  
RISEIN  
H1  
H2  
H3  
H4  
HR  
HO  
= 2ft  
= 1ft  
= 1ft  
= 1.5 ft  
INCHES (VT)  
= H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft  
= .03(one 45º elbow + three 90º elbow -135º)  
=.03(315-135)=5.4ft  
HT  
= HR + HO = 5.5 +5.4 = 10.9 ft  
HT + VT = 10.9 + 5.5 = 16.4 ft  
Formula 1:HT < 4.2 VT  
4.2 VT = 4.2 x 5.5 = 23.1 ft  
10.9 < 16.8  
Formula 2:HT + VT < 24.75 feet  
16.4 < 24.75  
HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (HT)  
The shaded area within the lines represents acceptable  
values for HT and VT .  
Since both formulas are met, this vent configuration is ac-  
ceptable.  
For vent configurations requiring more than one 45º and  
90° elbow the following formulas apply:  
Formula 1: HT < 4.2 VT  
Formula 2: HT + VT < 24.75 feet  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
VERTICAL TERMINATION  
Example 3:  
when (HT) < (VT)  
Simple venting configurations  
V2  
FIGURE 9  
FIGURE10  
90°  
90°  
H2  
45°  
V1  
45°  
90°  
H1  
See graph to determine the required vertical rise VT for the  
required horizontal run HT.  
V1  
V2  
VT  
=5ft  
=10 ft  
V1  
=3ft  
=2.5 ft  
= H1 + H2 = 3 + 2.5 = 5.5 ft  
=
+
V2 = 5 + 10 = 15 ft  
H1  
H2  
HR  
HO  
REQUIRED VERTICAL RISE IN  
FEET (VT)  
= .03(one 45º elbow + three 90º elbows - 135º)  
= .03(45+90+90+90-135)=5.4  
HT  
=HR + HO = 5.5 + 5.4 = 10.9 ft  
HT + VT = 10.9 + 15 = 25.9 ft  
Formula 1: HT < VT  
10.9 < 15  
Formula 2: HT + VT < 40 feet  
25.9 < 40  
Since both formulas are met, this vent configuration is ac-  
ceptable.  
HORIZONTAL VENT RUN  
PLUS OFFSETS IN FEET (HT)  
The shaded area within the lines represents acceptable  
values for HT and VT.  
For vent configurations requiring more than one 45º and  
one 90° elbow , the following formulas apply:  
Formula 1: HT < VT  
Formula 2: HT + VT < 40 feet  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
VERTICAL TERMINATION  
when (HT) > (VT)  
V1  
V2  
VT  
=1ft  
Simple venting configurations  
=1.5 ft  
=
V1  
+
V2 = 1 + 1.5 = 2.5 ft  
FIGURE 11  
H1  
H2  
HR  
HO  
=6ft  
=2ft  
=H1 + H2 = 6 + 2 = 8 ft  
=.03(one 45º elbow + three 90º elbow - 135º)  
=.03(45 + 90 + 90 + 90 - 135) = 5.4 ft  
=HR + HO = 8 + 5.4 = 13.4 ft  
HT  
HT + VT = 13.4 + 2.5 = 15.9 ft  
Formula 1: HT < 3VT  
3VT  
=
3 x 2.5 = 7.5 ft  
13.4 > 7.5  
Since this formula is not met, this vent configuration is  
unacceptable.  
See graph to determine the required vertical rise VT for the  
required horizontal run HT.  
Formula 2: HT + VT < 40 feet  
15.9 < 40  
Since only formula 2 is met, this vent configuration is unac-  
ceptable and a new fireplace location or vent configuration  
will need to be established to satisfy both formulas.  
REQUIRED  
VERTICAL  
RISE  
IN  
Example 5:  
FEET (VT)  
V2  
90°  
H2  
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (HT)  
45°  
V1  
The shaded area within the lines represents acceptable  
values for HT and VT.  
90°  
H3  
H1  
45°  
90°  
FIGURE 13  
For vent configurations requiring more than one 45º and  
one 90° elbow , the following formulas apply:  
Formula 1: HT < 3VT  
V1  
V2  
VT  
=1.5 ft  
=8ft  
Formula 2: HT + VT < 40 feet  
Example 4:  
=
V1  
+
V2 = 1.5 + 8= 9.5 ft  
H1  
H2  
H3  
HR  
HO  
=1ft  
=1ft  
=10.75 ft  
=H1 + H2 + H3 = 1 + 1 + 10.75 = 12.75 ft  
=.03(three 90° elbows + two 45° elbow - 135°)  
=.03(90 + 90 + 90 + 45 + 45 - 135) = 6.75 ft  
=HR + HO = 12.75 + 6.75 = 19.5 ft  
45°  
90°  
V2  
HT  
H1  
H2  
HT + VT = 19.5 + 4.5= 29 ft  
V1  
Formula 1: HT < 3VT  
90°  
3VT = 3 x 9.5 = 28.5 ft  
90°  
19.5 < 28.5  
Formula 2: HT + VT < 40 feet  
29 < 40  
FIGURE 12  
Since both formulas are met, this vent configuration is ac-  
ceptable.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
INSTALLATION  
WALL AND CEILING PROTECTION  
FOR SAFEAND PROPER OPERATION OF THE FIREPLACE,  
FOLLOW THE VENTING INSTRUCTIONS EXACTLY.  
VERTICAL INSTALLATION  
NOTE: Only a clearance to combustibles of 1" all  
around the vent pipe is required.  
FIGURE 16  
This application occurs  
when venting through a  
roof. Installation kits for  
various roof pitches are  
available from your Con-  
tinental dealer. See Ac-  
cessories to order the  
specific kit required.  
HORIZONTAL INSTALLATION  
This application occurs when vent-  
ing through an exterior wall. Having  
determined the air terminal loca-  
tion, cut and frame a hole in an ex-  
terior wall with a minimum open-  
ing as required. See Note above.  
(As an alternative to framing, a vent  
pipe shield may be installed, en-  
1. Determine the air terminal location, cut and frame 10  
inch openings in the ceiling and the roof to provide the  
minimum 1 inch clearance between the fireplace pipe /  
liner and any combustible material. Try to center the ex-  
haust pipe location midway between two joist to prevent  
having to cut them. Use a plumb bob to line up the center of  
the openings. DO NOT FILL THIS SPACE WITH ANY TYPE  
OF MATERIAL. A vent pipe shield will prevent any materials  
such as insulation, from filling up the 1" air space around  
the pipe. Nail head-  
suring  
a
1" clearance to  
FIGURE 14  
combustibles. See Figure 16.)  
1. Mark and cut the vent pipe shield to the determined  
depth of the combustible wall. Apply a bead of caulking  
(not supplied) to the framework or to the shield plate (in the  
case of a finished wall) and secure the shield through the  
opening to the interior wall. The final location of the vent  
pipe shield should maintain the required clearance to the  
8" vent pipe / liner. (See note above). Do not fill this cavity  
with any type of material. Apply a bead of caulking all around  
and place a firestop spacer over the vent shield to restrict  
cold air from being drawn into the room or around the fire-  
place. Ensure that both spacer and shield maintain the  
required clearance to combustibles. Once the vent  
pipe / liner is installed in its final position, apply sealant  
between the pipe / liner and the firestop spacer.  
ers between the joist  
for extra support.  
2. Apply a bead of  
caulking (not sup-  
plied) to the frame-  
work or to the Wolf  
Steel vent pipe shield  
FIGURE 17  
plate or equivalent (in the case of a finished ceiling), and  
secure over the opening in the ceiling. FIGURE 18. Afirestop  
must be placed on the bottom of each framed opening in a  
roof or ceiling that the venting system passes through. Ap-  
ply a bead of caulking all around and place a firestop spacer  
over the vent shield to restrict cold air from being drawn  
into the room or around the fireplace. Ensure that both  
spacer and shield maintain the required clearance to  
combustibles. Once the vent pipe / liner is installed in its  
final position, apply sealant between the pipe / liner and  
the firestop spacer.  
OR  
FIGURE 15  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
USING FLEXIBLE VENT COMPONENTS  
Use only approved aluminum flexible liner kits marked:  
"Wolf Steel Approved Venting" as identified by the stamp only on the 8” outer liner.  
5. Apply a heavy bead of the high temperature sealant,  
supplied with the unit, to the inside of the 5" liner approxi-  
mately 1" from the end. Slip the liner a minimum of 2" over  
the fireplace vent collar and secure with 3 #8 screws.  
For safe and proper operation of the fireplace, follow  
the venting instructions exactly.  
HORIZONTAL AIR TERMINAL INSTALLATION  
6. Using the 8" diameter flexible aluminium liner, apply  
sealant, slide a minimum of 2" over the fireplace combus-  
tion air collar and secure with 3 #8 screws.  
AVENT HEAT SHIELD MUST BE USED IF THE WALLTERMI-  
NAL IS INSTALLED ON COMBUSTIBLE, EXTERIOR SUR-  
FACES.  
7. If more liner needs to be used to reach the fireplace,  
couple them together as illustrated. The vent system must  
be supported approximately every 3 feet for both vertical  
and horizontal runs. Use noncombustible strapping to  
maintain the minimum 1" clearance to combustibles.  
1. Cut or frame a hole in an exterior wall with a minimum  
round or square opening of 10½ inches. Secure the firestop  
spacer over the opening to the interior wall.  
2. Stretch the 5" diameter aluminum flexible liner to the  
required length taking into account the additional length  
needed for the finished wall surface. Slip the liner a mini-  
mum of 2" over the inner sleeve of the air terminal and  
secure with 3 #8 screws. Apply a heavy bead of the high  
temperature sealant.  
8. The vent heat shield  
must be installed only  
when terminating hori-  
zontally with no vertical  
rise. Remove the two  
screws nearest the vent  
collars on the top of the  
fireplace. Align the vent  
heat shield (supplied) and  
secure.See figure 37.  
FIGURE 20  
3. Using the 8" diameter flexible aluminum liner, slide  
over the outer combustion air sleeve of the air terminal and  
secure with 3 #8 screws. Seal as before.  
FIGURE 18  
VERTICAL AIR TERMINAL INSTALLATION  
FIGURE 21  
1. Fasten the roof support  
to the roof using the  
screws provided. The roof  
support is optional. In this  
case the venting is to be  
adequately supported us-  
ing either an alternate  
method suitable to the au-  
thority having jurisdiction or the optional roof support.  
The air terminal mounting plate may be recessed into  
the exterior wall or siding by 1½", the depth of the return  
2. Stretch the 5" diameter aluminium flexible liner to the  
required length. Slip the liner a minimum of 2" over the  
inner sleeve of the air terminal and secure with 3 #8 screws.  
Seal using a heavy bead of the high temperature sealant.  
flange.  
FIGURE 19  
3. Repeat using 8" diameter  
aluminium flexible liner.  
FIGURE 22  
4. Thread the air terminal pipe  
assembly down through the roof.  
The air terminal must be located  
vertically and plumb.Attach the air  
terminal assembly to the roof  
support, ensuring that a mini-  
mum 16" of air terminal will pen-  
etrate the roof when fastened.  
4. Insert the liners through the firestop maintaining the  
required clearance to combustibles. Holding the air termi-  
nal (lettering in an upright, readable position), secure to  
the exterior wall and make weather tight by sealing with  
caulking (not supplied).  
DONOTCLAMPTHEFLEXIBLE  
ALUMINIUM LINER.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
7. If more liner needs to be used to reach the fireplace,  
5. Remove nails from the shingles, above and to the  
sides of the chimney. Place the flashing over the air termi-  
nal and slide it underneath the sides and upper edge of  
the shingles. Ensure that the air terminal is properly cen-  
tred within the flashing, giving a 3/4" margin all around.  
Fasten to the roof. Do not nail through the lower portion of  
the flashing. Make weather-tight by sealing with caulking.  
Where possible, cover the sides and top edges of the flash-  
ing with roofing material.  
couple them together as illustrated. The vent system must be  
supported approximately every 3 feet for both vertical and hori-  
zontal runs. Use noncombustible strapping to maintain a  
clearance to combustibles of 1".  
FIREPLACE VENT CONNECTION  
1. Install the 5 inch diameter aluminium flexible liner to  
the fireplace. Secure with 3 screws and flat washers. Seal  
the joint and screw holes using the high temperature seal-  
ant provided.  
6. Apply a heavy bead of weatherproof caulking 2 inches  
above the flashing. Slide the storm collar around the air  
terminal and down to the caulking. Tighten to ensure that a  
weather-tight seal between the air terminal and the collar  
is achieved. Attach the other storm collar centred between  
the air intake and the air exhaust slots onto the air termi-  
nal. Tighten securely. Attach the vertical rain cap.  
2. Install the 8 inch diameter aluminium flexible liner to  
the fireplace. Attach and seal the joints.  
FIGURE 24  
Spacers are at-  
tached to the 5" in-  
ner flex liner at pre-  
determined intervals  
to maintain a 1-1/4"  
air gap to the 8" outer  
liner. These spacers  
must not be re-  
moved.  
FIGURE 23  
USING RIGID VENT COMPONENTS  
3. The vent heat shield  
must be installed only when  
terminating horizontally with  
no vertical rise. Remove the  
two screws nearest the vent  
collars on the top of the fire-  
place. Align the vent heat  
shield (supplied) and secure.  
See figure 37.  
The vent system must be supported approximately every 3  
feet for both vertical and horizontal runs. Use Wolf Steel  
vent spacers every 3 feet and either side of each elbow to  
maintain the minimum 1¼" clearance between the outer  
and inner vent pipes. Use Wolf Steel support ring assem-  
bly or equivalent noncombustible strapping to maintain the  
minimum clearance to combustibles for both vertical and  
horizontal runs.  
FIGURE 26  
HORIZONTAL AIR TERMINAL INSTALLATION  
4. Holding the air terminal (with the air deflectors to the  
top), insert into both vent pipes with a twisting motion to ensure  
that both the terminal sleeves engage into the vent pipes and  
sealant. Secure the terminal to the exterior wall and make  
weather tight by sealing with caulking (not supplied).  
AVENT HEAT SHIELD MUST BE USED IF THE WALL TERMI-  
NAL IS INSTALLED ON COMBUSTIBLE, EXTERIOR SUR-  
The air terminal mounting plate may be recessed into the  
exterior wall or siding by 1½", the depth of the return flange.  
EXTENDED HORIZONTAL AIR TERMINAL  
INSTALLATION  
FIGURE 27  
1. Follow the instructions for  
"Horizontal Air Terminal Installa-  
tions", items 1 to 3.  
FIGURE 25  
2. Continue adding components  
FACES.  
alternating inner and outer venting.  
Ensure that all 5" venting and el-  
1. Move the fireplace into po-  
bows have sufficient vent spacers attached and  
each component is securely fastened to the one  
prior.Attach the 5" telescopic sleeve to the vent run.  
Repeat using a 8" telescopic sleeve. Secure and  
seal as before. To facilitate completion, attach 5"  
and 8" couplers to the air terminal.  
3. Install the air terminal. See item 3 of the Hori-  
zontal Air Terminal Installation. Extend the 5" telescopic  
sleeve; connect to the air terminal assembly. Fasten with  
self tapping screws and seal. Repeat using the 8" tel-  
sition. Measure the vent length  
required between terminal and  
fireplace taking into account the  
additional length needed for the finished wall surface and any  
1¼" overlaps between venting components.  
2. Apply high temperature sealant to the outer edge of the 5"  
inner collar of the fireplace. Attach the first vent component and  
secure using 3 self tapping screws. Repeat using 8" piping.  
escopic sleeve.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
VERTICAL VENTING INSTALLATION  
RESTRICTING VERTICAL VENTS  
1. Move the fireplace into position.  
Vertical terminations may display a very active flame. If this  
appearance is not desirable, the vent exit must be restricted  
using restrictor plate, W080-0454. This reduces the veloc-  
ity of the exhaust gases, slowing down the flame pattern  
and creating a more traditional appearance.  
2. Fasten the roof support to the roof using the screws  
provided. FIGURE 21. The roof support is optional. In this  
case the venting is to be adequately supported using ei-  
ther an alternate method suitable to the authority having  
jurisdiction or the optional roof support.  
GAS INSTALLATION  
3. Apply high temperature sealant to the outer edge of the  
inner sleeve of the air terminal. Slip a 5" diameter coupler a  
minimum of 2" over the sleeve and secure using 3 screws.  
Proceed once the vent installation is complete.  
1. Move the fireplace into position and secure using the  
nailing tabs and/or secure to the floor through the ¼"diam-  
eter holes located at either end of the base.  
4. Apply high temperature seal-  
ant to the outer edge of the of the  
outside sleeve of the air terminal.  
FIGURE 28  
2. Route a 3/8" N.P.T. black iron gas line, 1/2" type-L cop-  
Slip a 8" diameter coupler over the  
sleeve and secure as before. FIG-  
URE 25. Trim the 8" coupler even  
with the 5" coupler end.  
per tubing or equivalent to the fireplace.  
3. For ease of accessibility, an optional remote wall switch  
or millivolt thermostat may be installed in a convenient lo-  
cation. Route 2-strand (solid core) millivolt wire through  
the electrical hole located at the bottom left side of the unit.  
The recommended maximum lead length depends on wire  
5. Thread the air terminal pipe  
assembly down through the roof  
support and attach, ensuring that  
a minimum 16" of air terminal will  
penetrate the roof when fas-  
tened. FIGURE 24. If the attic  
space is tight, we recommend  
threading the Wolf Steel vent pipe  
collar or equivalent loosely onto  
the air terminal assembly as it is  
passed through the attic.  
FIGURE 28. The air terminal must  
be located vertically and plumb.  
size:  
WIRE SIZE  
14 gauge  
16 gauge  
18 gauge  
MAX. LENGTH  
100 feet  
60 feet  
VENT  
PIPE  
40 feet  
COLLAR  
Attach the two leads to terminals 1 and 3 located on the  
gas valve.  
VENT PIPE  
1
2
SHIELD  
FIGURE 30  
I
FIGURE 29  
3
6. Remove nails from the shingles, above and to the  
sides of the chimney. Place the flashing over the air termi-  
nal and slide it underneath the sides and upper edge of  
the shingles. Ensure that the air terminal is properly  
centered within the flashing, giving a 3/4" margin all around.  
Fasten to the roof. Do NOT nail through the lower portion of  
the flashing. Make weather-tight by sealing with caulking.  
Where possible, cover the sides and top edges of the flash-  
ing with roofing material. FIGURE 23.  
4. Install rigid black pipe, 1/2" type-L copper tubing or, if  
local codes permit, a 3/8" flex connector and shutoff valve  
to the gas line and the fireplace gas valve.  
FIGURE 31  
7. Apply a heavy bead of waterproof caulking 2 inches  
above the flashing. Slide the storm collar around the air  
terminal and down to the caulking. Tighten to ensure that a  
weather-tight seal between the air terminal and the collar  
is achieved. Attach the other storm collar centered between  
the air intake and air exhaust slots onto the air terminal.  
Tighten securely. Attach the rain cap.  
Seal and tighten securely. An adapter fitting is required  
between the gas valve and the copper tubing or flex con-  
nector.  
Do not kink flex connector.  
5. Check for gas leaks by brushing on a soap and water  
solution.  
8. Continue adding rigid venting sections, sealing and  
securing as above. Attach a 5" collapsed telescopic pipe  
to the last section of rigid piping. Secure with screws and  
seal. Repeat using a 8" telescopic pipe.  
Do not use open flame.  
Do not connect either the wall switch, thermostat or gas  
valve to electricity (110 volts).  
Purge all gas lines with the glass door of the fireplace  
removed. Assure that a continuous gas flow is at the  
burner before re-installing the door.  
9. Run a bead of high temperature sealant around the  
outside of the 5" collar on the fireplace. Pull the adjustable  
pipe a minimum of 2" onto the collar. Secure with 3 screws.  
Repeat with the 8" telescopic pipe.  
10. In the attic, slide the vent pipe collar down to cover up  
the open end of the shield and tighten. This will prevent  
any materials, such as insulation, from filling up the 1" air  
space around the pipe.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
It is best to frame your fireplace after it is positioned and  
MOBILE HOME INSTALLATION  
the vent system is installed. Use 2x4's and frame to local  
building codes. FIGURES 31-33.  
In Canada, mobile home installation may be vented hori-  
zontally or vertically. In the United States, it may only be  
installed vertically. See "Vertical Venting" or "Horizontal Air  
Terminal Installation" for installation.  
It is not necessary to install a hearth extension with this  
fireplace system.  
When roughing in the fireplace, raise the fireplace to ac-  
commodate for the thickness of the finished floor materi-  
als, i.e. tile, carpeting, hard wood, which if not planned for  
will interfere with the opening of the lower access door and  
the installation of many decorative flashing accessories.  
The fireplace is equipped with two 1/4" diameter holes  
located in the front left and right corners of the base. For  
mobile home installations, the fireplace must be fastened  
in place. Use #10 hex head screws, inserted through the  
holes in the base to secure. It is recommended that the  
fireplace be secured in all installations.  
Objects placed in front of the fireplace should be kept a  
minimum of 48" away from the front face.  
Always turn off the pilot and the fuel supply at the  
source, prior to moving the mobile home.  
Combustible materials may be installed flush with the front  
of the fireplace but must not cover or protrude past any of  
the black face-areas of the fireplace. Non-combustible ma-  
terial (brick, stone or ceramic tile) may protrude in these  
areas.  
After moving the mobile home and prior to lighting the  
fireplace, ensure that the logs are positioned correctly.  
FRAMING  
Note: In order to avoid the possibility of exposed insulation  
or vapour barrier coming in contact with the fireplace body,  
it is recommended that the walls of the fireplace enclo-  
sure be “finished” (ie: drywall/sheetrock),as you would fin-  
ish any other outside wall of a home. This will ensure that  
clearance to combustibles is maintained within the cavity.  
FIGURE 33  
FIGURE 32  
FIGURES 34  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
FIGURES 35a-c  
NAILING TAB INSTALLATION  
CORNER  
POST  
1) Attach the nailing tabs to the corner  
posts using the 2 sheet metal screws  
supplied. Secure through the centre of  
the top and bottom slots in the nailing  
tab and then through the existing holes  
in the corner posts.  
NAILING  
TAB  
TOP SLOT  
NAILING  
TAB  
If there are no existing holes, follow  
these instructions:  
Position the nailing tab so that the front  
face is offset with the front edge of the  
corner post (approx. ½"). Centre the  
nailing tab vertically on the corner post.  
Figure 35 a.  
Drill through the centre of the top and  
bottom slots in the nailing tab. Secure  
using the two sheet metal screws sup-  
plied. This allows the nailing tab to slide back  
and forth for desired framing. Figure 35b.  
2) To determine the final location of the nailing tab you  
must first determine the thickness of your finishing mate-  
rial (i.e. drywall). This will determine the dimension from  
the front edge of the corner post to the nailing tab. Once  
the nailing tab is in the desired location, drill through the  
centre hole of the nailing tab. Secure with a sheet metal  
screw*. Figure 35c.  
* Additional set screws may be installed.  
A
B
MANTLE INSTALLATION  
FINISHING  
MATERIAL  
Combustible mantle clearance can vary according to the  
mantle depth. FIGURE 36. Use the graph to help evaluate  
the clearance needed. Curtains, above the fireplace, must  
not be positioned lower than the 5" distance required for  
the 2" combustible mantle. These same requirements  
apply to any combustibles protruding on either side of  
the fireplace.  
FIGURE 36  
CENTRE  
HOLE  
FIGURE 37  
C
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
FINISHING  
L42 LOUVRE INSTALLATION  
LOGO PLACEMENT  
Remove  
the  
FIGURE 38  
backing of the  
logo supplied and  
place on the glass  
viewing door, as  
indicated.  
½"  
LOGO  
A
½"  
FIGURE 39  
PORCELAIN REFLECTIVE PANELS  
B
1. Remove the upper louvres, and open the glass door.  
Remove the logs.  
FIGURES 40a  
2. Remove the securing screw al-  
ready in place at the back of the fire-  
box. If the unit is supplied with a rear  
log support, remove before install-  
ing the rear brick panel. Place the  
rear panel against the back of the  
firebox and re-install the rear log support over the brick  
panel, if supplied. Secure using the original screw.  
3. Remove the two securing screws located on either fire-  
box side.  
UPPER LOUVRES  
Insert the louvre tabs into the  
slots located at the top left and  
right corners of the unit.  
SLOT  
TAB  
4. Place the left brick panel  
against the left side of the firebox,  
ensuring that it butts up to the rear  
panel. Secure in place using 2 of  
the screws previously removed.  
Repeat for the right side.  
A
B
LOWER LOUVRES  
HINGE  
CLIP  
SLOT  
Insert the hinge clips into the  
slots located at the bottom left  
and right corners of the unit.  
5. Replace the logs, glass door  
To remove the louvres, pull the  
back tabs of the clips forward,  
while pushing the louvre assem-  
bly back. Lift the clip.  
and louvres.  
FIGURE 40b  
NOTE: MBP42 Shown. Mortar lines not available on PRP42.  
The appearance of the panels will permanently lighten in  
colour with use.  
FIGURES 40a-b  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
LOG PLACEMENT  
PHAZERTM logs and glowing embers, exclusive to Conti-  
nental Fireplaces, provide a unique and realistic glowing  
effect that is different in every installation. Take the time to  
carefully position the glowing embers for a maximum glow-  
ing effect. Log colours may vary. During the initial use of the  
fireplace, the colours will become more uniform as colour  
pigments burn in during the heat activated curing process.  
#5  
#4  
FIGURES41a-d  
4. Cradle the notch on the bottom of the left crossover log  
(#4) around the left outermost grate post and the top into  
the pocket provided on the back log. Position the notch  
located on the end of the center log (#5) against the middle  
grate post with the other end of the log resting in the pocket  
of the left crossover log.  
#1  
1. Place the back log (#1) onto the log support tray and in  
front of the tabs. The tabs maintain an air space between  
the log and firebox back to facilitate combustion air flow.  
Ensure that the back of the log rests against the brackets  
on the back wall of the firebox.  
#6  
5. Place the bottom of the right crossover log (#6) against  
the right outermost grate post. The post should rest in the  
pocket formed by the knot and the top into the pocket pro-  
vided on the center log (#5).  
#2  
#3  
CHARCOAL EMBERS  
2. Move the two small logs (#2 & #3) into position, lining  
up the studs located on the burner with the holes on the  
bottom of the logs.  
Randomly place the charcoal embers along the front and  
sides of the log support tray in a realistic manner. Fine  
dust found in the bottom of the bag should not be used.  
VERMICULITE  
Sprinkle vermiculite around the charcoal embers.  
GLOWING EMBERS  
Note: Both charcoal embers and vermiculite are not to  
be placed on the burner.  
3. Tear the glowing embers into pieces and place along  
the front row of ports covering all of the burner area in front of  
the small logs (#2 & #3). Care should be taken to shred the  
embers into thin, small irregular pieces as only the exposed  
edges of the fibre hairs will glow. The ember material will  
only glow when exposed to direct flame; however, care should  
be taken to not block the burner ports. Blocked burner ports  
can cause an incorrect flame pattern, carbon deposits and  
delayed ignition. PHAZERTM logs glow when exposed to di-  
rect flame.  
CHARCOAL LUMPS  
Place the lumps between the logs in a realistic manner  
taking care not to block any of the burner ports.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
OPTIONAL BLOWER INSTALLATION  
Attach the connectors  
from the black and white  
wires to the thermodisc  
THERMODISC  
and  
secure  
the  
thermodisc bracket to the  
securing stud at the bot-  
tom left of the unit using  
a lock washer and wing  
nut. Ensure that the  
thermodisc touches the  
firebox wall.  
RECEPTACLE /  
BOX  
JUNCTION  
GROUND  
SCREW  
FIGURE 42  
Attach the connectors  
from the black and red  
wires to the blower.  
FIGURE 46  
INSTALLATION TO BE DONE BYAQUALIFIED INSTALLER  
and must be electrically connected and grounded in ac-  
cordance with local codes. In the absense of local codes,  
use the current CSA C22.1 CANADIAN ELECTRICAL CODE in  
Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the  
United States  
Attach and secure the vari-  
able speed switch using  
the nut provided. Plug the  
harness cord into the re-  
ceptacle.  
If the fireplace was not previously equipped with a  
blower: route a grounded 2-wire, 60hz power cable to the  
receptacle / junction box. At this point, it must be strain  
relieved and insulated.  
FIGURE 47  
ELONGATED  
The three slots on the  
The wire harness provided in this kit is a universal  
harness. When installed, ensure that any excess  
wire is contained, preventing it from making con-  
tact with moving or hot objects.  
SLOTS  
blower  
bracket allow ease of  
adjustment when  
mounting  
attaching the blower.  
For a quiet running  
blower, do not allow the  
assembly to sit on the  
firebox base.  
Because the blower is thermally activated, when  
turned on, it will automatically start approximately  
10 minutes after lighting the fireplace and will run  
for approximately 30-45 minutes after the fire-  
place has been turned off. Use of the fan increases  
the output of heat.  
FIGURE 43  
Slide the vibration reducing pad (A) into the clip (C) and up  
against the threaded stud (B) at the other end. The blower  
must be able to be positioned entirely onto the pad.  
Tilt the blower onto its side. Slide it past the controls and  
into the clip (C). Secure to the threaded stud using the lock  
washer and wing nut provided. Ensure that the blower  
does not touch the fireplace base or the firebox.  
Drywall dust will penetrate into the blower bear-  
ings, causing irreparable damage. Care must be  
taken to prevent drywall dust from coming into  
contact with the blower or its compartment. Any  
damage resulting from this condition is not cov-  
ered by the warranty policy.  
B
C
A
FIGURE 44  
FIGURE 45  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
OPTIONAL FAN INSTALLATION  
ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-  
If the fireplace was not previously equipped with a fan:  
route a grounded 2-wire, 60hz power cable to the junction  
box. At this point, it must be strain relieved and insulated.  
FIED INSTALLER and must be connected and grounded  
in accordance with local codes. In the absence of local  
codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in  
Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the  
United States.  
The wire harness provided in this kit is a universal har-  
ness. When installed, ensure that any excess wire is con-  
tained, preventing it from making contact with moving or  
hot objects.  
To safely install the fan, turn off the electricity first.  
FIGURE 49  
OPTIONAL THERMOSTATIC  
SENSOR  
To ease installation of the fan, re-  
move the hinge screen and valve  
control door (lower louvres) from  
the base of the fireplace.  
RECEPTACLE /  
JUNCTION BOX  
VARIABLE SPEED/  
PIEZO IGNITOR  
BRACKET  
Position the vibration reducing pad  
into the clip and onto the threaded  
stud at the other end, piercing a hole into the pad. The fan  
assembly must be able to be positioned entirely onto the  
pad.  
OPEN ENDED  
SLOTS  
Slide the fan assembly past the controls and into the clip.  
Secure using the lock washer and nut provided.  
FIGURE 48  
Plug the harness cord into the receptacle.  
GD36 THERMOSTATIC SENSOR CONTROL  
This optional kit is meant to be used only in conjunction  
with the GD65 Fan Kit, shown above, which may be or-  
dered from your Wolf Steel / Continental dealer.  
Use of the fan increases the output of heat.  
Unplug the power cord from the receptacle. Connect all  
wires as shown.  
With the thermostatic sensor option, the fan, when turned  
on, becomes thermally activated, and will automatically run  
approximately 15-30 minutes after the fireplace has been  
lit and for approximately 30-45 minutes after the fireplace  
has been turned off.  
Attach and secure the sensor assembly bracket to the se-  
curing stud located next to the receptacle/junction box at  
the bottom left of the unit using the lock washer and wing  
nut. Ensure that the thermodisc touches the firebox wall.  
Plug the power cord back into the receptacle.  
THERMODISC  
When installed, ensure that any excess wire is contained,  
preventing it from making contact with moving or hot ob-  
jects.  
SENSOR ASSEMBLY  
BRACKET  
FIGURE 51  
RECEPTACLE /  
JUNCTION BOX  
FIGURE 50  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
OPERATION / MAINTENANCE  
After extended periods of non-operation such as following  
a vacation or a warm weather season, the fireplace may  
OPERATING INSTRUCTIONS  
When lit for the first time, the fireplace will emit a slight emit a slight odour for a few hours. This is caused by dust  
odour for a few hours. This is a normal temporary condi- particles in the heat exchanger burning off. In both cases,  
tion caused by the curing of the logs and the "burn-in" of open a window to sufficiently ventilate the room.  
internal paints and lubricants used in the manufacturing  
process and will not occur again.  
Purge the gas line with the glass door removed. As-  
sure that a continuous gas flow is at the burner before  
re-installing the door.  
FOR YOUR SAFETY READ BEFORE LIGHTING:  
WHAT TO DO IF YOU SMELL GAS  
A. This fireplace is equipped with a pilot which must be  
lit by hand while following these instructions exactly.  
• Turn off all gas to the fireplace.  
• Open windows.  
B. Before operating smell all around the fireplace area  
for gas and next to the floor because some gas is  
heavier than air and will settle on the floor  
C. Use only your hand to turn the gas control knob. Never  
use tools. If the knob will not turn by hand, do not try to  
repair it. Call a qualified service technician. Force or  
attempted repair may result in a fire or explosion.  
• Do not try to light any appliance.  
• Do not touch any electric switch; do  
not use any phone in your building.  
GAS KNOB  
• Immediately call your gas supplier from a neighbour's  
phone. Follow the gas supplier's instructions.  
• If you cannot reach your gas supplier, call the fire de-  
partment.  
D. Do not use this fireplace if any part has been under  
water. Immediately call a qualified service technician to  
inspect the fireplace and replace any part of the control  
system and any gas control which has been under water.  
LIGHTING INSTRUCTIONS  
WARNING: The gas valve has an interlock device which  
will not allow the pilot burner to be lit until the thermocou-  
ple has cooled. Allow approximately 60 seconds for the  
thermocouple to cool.  
5. Turn gas knob counter-clockwise  
to pilot.  
6. Depress slightly and hold gas knob while lighting the  
pilot with the push button ignitor. Keep knob depressed  
for one minute, then release. If pilot does not continue to  
burn, repeat steps 3 through 5.  
When lighting and re-lighting, the gas knob cannot be  
turned from pilot to off unless the knob is depressed  
slightly.  
7. With pilot lit, depress and turn gas knob counter-clock-  
wise  
to on.  
1. Stop! Read the above safety information on this label.  
2. Turn off all electric power to the fireplace.  
8. If equipped with remote on-off switch/thermostat, main  
burner may not come on when you turn valve to on. Remote  
switch must be in the on position to ignite burner.  
3. Turn the gas knob clockwise  
to off.  
9. Turn on all electric power to the fireplace.  
4. Wait five (5) minutes to clear out any gas. If you smell gas  
including near the floor. Stop! Follow "B" in the above safety  
information on this label. If you don't smell gas go the next  
step.  
TO TURN OFF GAS  
1. Turn off all electric power to the fireplace if service is 2. Push in gas control knob slightly and turn clock-  
to be performed.  
wise  
to off. Do not force.  
MAINTENANCE  
Turn off the gas and electrical power before servicing 3. Check to see that all burner ports are burning. Clean out  
any of the ports which may not be burning or are not burn-  
ing properly.  
4. Check to see that the pilot flame is large enough to  
engulf the thermocouple and thermopile and reaches to-  
ward the burner with the third jet.  
the fireplace.  
CAUTION: Label all wires prior to disconnection when serv-  
icing controls. Wiring errors can cause improper and dan-  
gerous operation. Verify proper operation after servicing.  
This fireplace and its venting system should be inspected  
before use and at least annually by a qualified service  
person. The fireplace area must be kept clear and free of  
combustible materials, gasoline or other flammable va-  
pours and liquids. The flow of combustion and ventilation  
air must not be obstructed.  
5. Replace the cleaned logs.  
6. Check to see that the main burner ignites completely on all  
openings when the gas knob for the burner is turned on. A 5 to  
10 second total light-up period is satisfactory. If ignition takes  
longer, consult your Continental dealer / distributor.  
7. Check that the gasketing on the sides, top and bottom of  
the door is not broken or missing. Replace if necessary.  
1. In order to properly clean the burner and pilot assembly,  
remove the logs to expose both assemblies.  
2. Keep the control compartment, logs, burner, air shutter  
opening and the area surrounding the logs clean by vacu-  
uming or brushing, at least once a year.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
ADJUSTMENTS  
PILOT BURNER ADJUSTMENT  
Closing the air shutter will cause a more yellow flame, but  
can lead to carboning. Opening the air shutter will cause a  
more blue flame, but can cause flame lifting from the burner  
ports. The flame may not appear yellow immediately; allow  
15 to 30 minutes for the final flame colour to be estab-  
lished.  
Adjust the pilot screw to provide properly sized flame. Turn  
in a clockwise direction to reduce the gas flow.  
I
FIGURE 54  
PILOT SCREW  
FIGURE 52  
FIGURE 53  
Air shutter adjustment must only be done by a  
qualified installer!  
VENTURI ADJUSTMENT  
Air shutters have been factory set open according to the  
chart below:  
VENTURI  
AIR SHUTTER  
COVER  
NG  
LP  
"
1/  
4
7
/ "  
16  
These settings are for the maximum horizontal vent run.-  
Adjustment may be required depending on fuel type, vent  
configuration and altitude.  
FIGURE 55  
To access the air shutter, remove the two screws that se-  
cure the cover to the air housing, taking care not to dam-  
age the gasket.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
REPLACEMENTS  
Contact your dealer or the factory for questions concerning 1. MODEL & SERIAL NUMBER OF FIREPLACE  
prices and policies on replacement parts. Normally all parts  
can be ordered through your Continental dealer or distribu-  
tor.  
2. INSTALLATION DATE OF FIREPLACE  
3. PART NUMBER  
4. DESCRIPTION OF PART  
5. FINISH  
When ordering replacement parts always give the follow-  
ing information:  
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE  
ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.  
ACCESSORIES  
REPLACEMENT PARTS  
#
PART NO. DESCRIPTION  
5" COUPLER  
#
1
2
3
4
4
5*  
6
6
7
PART NO. DESCRIPTION  
37* W175-0166  
37* W175-0002  
W357-0001  
W680-0004  
*W680-0005  
W010-0800  
W010-0801  
W573-0008  
W455-0069  
W455-0067  
W725-0025  
W725-0026  
W385-0245  
W750-0112  
W010-0864  
GL-641  
PIEZO IGNITER  
THERMOPILE  
THERMOCOUPLE  
8" COUPLER  
38  
38  
39  
39  
39  
40  
40  
40  
40  
CDV42-4L  
CDV42-24L  
L42K  
LOUVRE OVERLAY - POLISHED BRASS  
LOUVRE OVERLAY - POLISHED BRASS  
LOUVRE KIT - UPPER & LOWER - BLACK  
LOUVRE KIT - UPPER & LOWER - POLISHED BRASS  
NATURAL GAS PILOT ASSEMBLY  
PROPANE GAS PILOTASSEMBLY  
HIGH TEMPERATURE SEALANT  
NATURAL GAS PILOT INJECTOR  
PROPANE GAS PILOT INJECTOR  
NATURAL GAS VALVE  
PROPANE VALVE  
CONTINENTAL LOGO  
20FT OF WIRE  
PAN BURNER  
L42PB  
L42SS  
LOUVRE KIT - UPPER & LOWER - BRUSHED STAINLESS STEEL  
ORNAMENTAL INSET - BRUSHED GOLD  
ORNAMENTAL INSET - BLACK  
ORNAMENTAL INSET - GOLD  
ORNAMENTAL INSET - STAINLESS STEEL  
MILLIVOLTTHERMOSTAT  
GDOI42BG  
GDOI42K  
GDOI42G  
GDOI42SS  
7
8*  
9*  
10  
11  
41* W690-0001  
42* W660-0010B  
42* W660-0011B  
43* W660-0013  
44* GD825N  
44* GD825P  
45  
46  
47* W585-0096  
48* W010-0810  
49* W175-0170  
50  
51  
52  
REMOTE CONTROL - ADVANTAGE  
REMOTE CONTROL - ADVANTAGE PLUS  
MODULATING THERMOSTATIC HAND HELD REMOTE  
MODULATING VALVE REGULATOR FOR W660-0013 - NG  
MODULATING VALVE REGULATOR FOR W660-0013 - P  
FIRESTOP SPACER (RIGID VENTING)  
HEAT GUARD  
LOG SET  
12* W361-0016  
13* W550-0001  
14* W550-0002  
GLOWING EMBERS  
CHARCOAL EMBERS  
CHARCOAL LUMPS  
W500-0163  
GD501  
15  
16  
17  
18  
19  
20  
21  
22  
22  
W135-0198  
W135-0201  
W135-0202  
W135-0203  
W135-0199  
W135-0200  
W010-0770  
W455-0026  
W455-0003  
BACK LOG (#1)  
LEFT CROSSOVER LOG (#4)  
CENTER LOG (#5)  
RIGHT CROSSOVER LOG (#6)  
SMALL LEFT LOG (#2)  
SMALL RIGHT LOG (#3)  
BLACK DOOR C/W GLASS  
#38 NATURAL GAS ORIFICE  
#54 PROPANE GAS ORIFICE  
VERMICULITE  
SOFFIT HEAT SHIELD  
WALL SUPPORT ASSEMBLY  
DURA-VENT ZERO CLEARANCE ADAPTOR  
VENT PIPE COLLAR  
VENT PIPE SHIELD  
W170-0086  
W585-0092  
GZ550-1KT  
BLOWER KIT  
53* GD65  
54* GD36  
55* W500-0033  
56* KB35  
FAN KIT  
THERMOSTATIC SENSOR CONTROL KIT FOR USE WITH GD65 ONLY  
VARIABLE SPEED SWITCH WALL MOUNTING PLATE  
VARIABLE SPEED SWITCH  
23* W361-0014  
24 W500-0028  
FIRESTOP SPACER (FLEX VENTING)  
57  
GA-566  
HOT AIR DISTRIBUTION KIT  
THERMOSTAT - 110V FOR USE WITH GA-566 ONLY  
EXTENSION KIT - 5 FT  
HOT AIR EXHAUST KIT  
RESTRICTOR PLATE  
FLEXIBLE VENT KITS  
58* W690-0005  
59* GA-70  
60  
61* W080-0454  
62* W175-0211  
62* W175-0212  
* GD420 (5 FT)  
PART NO. DESCRIPTION  
GA-72  
25  
SPACERS  
W010-0772  
5" FLEXIBLE ALUMINIUM LINER - (5 FT) C/W  
CONVERSION KIT - NG-LP  
CONVERSION KIT - LP-NG  
25  
W730-0012  
8" FLEXIBLE ALUMINIUM LINER - (5 FT)  
* GD430 (10 FT)  
PART NO. DESCRIPTION  
26  
26  
27  
W730-0013  
W010-0773  
W010-0810  
8" FLEXIBLE ALUMINIUM LINER - (10 FT)  
5" FLEXIBLE ALUMINIUM LINER - (10 FT) C/W SPACERS  
WALL SUPPORT ASSEMBLY  
TERMINAL KITS  
28 PERISCOPE  
29 WALL TERMINAL KIT  
- GD401  
- GD422  
ROOF TERMINAL KITS  
30 1/12 TO 7/12 PITCH  
30 8/12 TO 12/12 PITCH  
30 FLAT ROOF  
-GD410  
-GD411  
-GD412  
PART NO. DESCRIPTION  
31  
32  
33  
34  
35  
36  
W010-0774  
W120-0015  
W170-0086  
W010-0453  
W263-0065 /  
W263-0066 /  
W263-0067  
AIR TERMINAL  
VERTICAL CAP  
STORM COLLAR  
ROOF SUPPORT  
ROOF FLASHING  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
TROUBLE SHOOTING GUIDE  
BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED.  
SYMPTOM  
PROBLEM  
TEST SOLUTION  
Main burner goes Pilot flame is not large - turn up pilot flame.  
out; pilot stays on. enough or not engulfing the  
thermopile  
- replace pilot assembly.  
Thermopile shorting  
- clean thermopile connection to the valve. Reconnect.  
- replace thermopile / valve.  
Remote wall switch wire is - shorten wire to correct length or wire gauge.  
too long; too much resist-  
ance in the system.  
Faulty thermostat or switch. - replace.  
Main burner goes  
out; pilot goes out.  
Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"  
- check for vent blockage.  
- check joint seals and installation.  
- re-attach to fireplace.  
Vent is blocked  
Vent is re-circulating  
5" flexible vent has become  
disconnected from fireplace.  
Pilot goes out when System is not correctly  
the gas knob is re- purged.  
- purge the gas line with the glass door removed.  
- fill the tank.  
leased.  
Out of propane gas.  
The gas valve has  
Pilot flame is not large - turn up the pilot flame.  
an interlock device  
which will not allow  
the pilot burner to  
be lit until the ther-  
enough  
Pilot flame is not engulfing - gently twist the pilot head to improve the flame pattern around the  
the thermocouple. thermocouple.  
Thermocouple shorting / - loosen and tighten thermocouple.  
mocouple  
has  
cooled. Allow ap-  
proximately 60  
seconds for the  
thermocouple to  
cool.  
faulty.  
- clean thermocouple and valve connection.  
- replace thermocouple.  
- replace valve.  
- replace.  
Faulty valve.  
- connect a jumper wire across the wall switch terminals; if main  
burner lights, replace switch / thermostat.  
Themostat or switch is de-  
fective.  
main  
Pilot burning; no  
gas  
to  
burner; gas knob  
is on 'HI'; wall  
switch / thermostat  
is on.  
Wall switch wiring is defec-  
tive.  
- disconnect the switch wires & connect a jumper wire across termi-  
nals 1 & 3; if the main burner lights, check the wires for defects and  
/ or replace wires.  
Main burner orifice is plugged. - remove stoppage in orifice.  
Faulty valve.  
- replace.  
Pilot will not light.  
No spark at pilot burner  
- check if pilot can be lit by a match  
- check that the wire is connected to the push button ignitor.  
- check if the push button ignitor needs tightening.  
- replace the wire if the wire insulation is broken or frayed.  
- replace the electrode if the ceramic insulator is cracked or broken.  
- replace the push button ignitor.  
Out of propane gas  
- fill the tank.  
Spark gap is incorrect  
- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from  
the electrode tip and the pilot burner. To ensure proper electrode  
location, tighten securing nut (finger tight plus 1/4 turn).  
- check that the manual valve is turned on.  
- check the pilot orifice for blockage.  
No gas at the pilot burner  
- replace the valve.  
- call the gas distributor.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
SYMPTOM  
PROBLEM  
TEST SOLUTION  
Pilot goes out Gas piping is undersized.  
while standing;  
Main burner is in  
- turn on all gas appliances and see if pilot flame flutters, dimin-  
ishes or extinguishes, especially when main burner ignites. Monitor  
appliance supply working pressure.  
'OFF' position.  
- check if supply piping size is to code. Correct all undersized piping.  
Flames are con- Unit is over-fired or under- - check pressure readings:  
sistently too large fired.  
or too small.  
Carboning occurs.  
Inlet pressure can be checked by turning screw (A) counter-clock-  
wise 2 or 3 turns and then placing pressure gauge tubing over the  
test point. Gauge should read 7" (minimum 4.5") water column for  
natural gas or 13" (11" minimum) water column for propane. Check  
that main burner is operating on "HI".  
B
A
Outlet pressure can be checked the same as above using screw (B).  
Gauge should read 3.5" water column for natural gas or 10" water  
column for propane. Check that main burner is operating on "HI".  
AFTER TAKING PRESSURE READINGS, BE SURE TO TURN  
SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE.  
Leak test with a soap and water solution.  
Door is ajar  
- fit door assembly into the lower support brackets and secure the  
four door latches.  
Flames are very  
aggressive.  
Venting action is too great.  
-restrict vent exit with restrictor plate, W080-0454.  
Main burner flame Blockage in vent.  
is a blue, lazy,  
- remove blockage. In extremely cold conditions, ice buildup may  
occur on the terminal and should be removed as required.  
transparent flame.  
- refer to Figure 23 to ensure correct location of storm collars.  
Incorrect installation.  
Carbon is being Air shutter has become  
- ensure air shutter opening is free of lint or other obstructions.  
deposited  
on blocked  
glass, logs or com-  
bustion chamber  
surfaces.  
Flame is impinging on the  
logs or combustion cham-  
ber.  
- check that the logs are correctly positioned.  
- open air shutter to increase the primary air.  
- check the input rate: check the manifold pressure and orifice size  
as specified by the rating plate values.  
- check that the door gasketing is not broken or missing and that the  
seal is tight.  
- check that both 5" and 8" vent liners are free of holes and well  
sealed at all joints.  
- check that minimum rise per foor has been adhered to for any  
horizontal venting.  
White / grey film Sulphur from fuel is being - clean the glass with a recommended gas fireplace glass cleaner.  
forms.  
deposited on glass, logs or DO NOT CLEAN GLASS WHEN HOT.  
combustion chamber sur-  
faces.  
If deposits are not cleaned off regularly, the glass may become  
permanently marked.  
- reverse.  
Remote  
wall Wall switch is mounted up-  
switch is in "OFF" side down  
position; main  
Remote wall switch is - replace.  
grounding.  
burner comes on  
when gas knob is  
turned to "ON" po-  
sition.  
Remote wall switch wire is - check for ground (short); repair ground or replace wire.  
grounding.  
- replace.  
Faulty valve.  
W415-0385 / A / 10.02.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Coleman Tent 2000001978 User Manual
Cooper Lighting Landscape Lighting WST50SR2554 User Manual
Country Home Products Snow Blower A2090TEA User Manual
Creda Clothes Dryer 5kg User Manual
Danby Range DR2009WGLP User Manual
Danby Refrigerator DBC7070BLSST User Manual
Dynamic Distributors Stud Sensor 103B11 User Manual
Dynaudio Speaker BM 5A User Manual
Dynex Stereo System DX AD116 User Manual
Generac Power Systems Portable Generator 005336 0 005337 0 User Manual