Revision History  
Rev. No.  
Released Date  
Description  
Rev. A  
Oct 16, 2009  
First Release  
Page 6  
Revise “Clone Function” operation method.  
Rev. A1  
Rev. A2  
Oct 22, 2009  
Nov 27, 2009  
Page 68  
Add “Save Configuration” and “Master Default” to System Commands.  
Page 53  
Page 69  
“Bluetooth Device Name” – Modify user define characters from 1 – 14  
characters to 1 – 16 characters.  
Add “Indications”.  
Page 25  
Page 43  
Page 45  
Page 48  
Modify UPC-E/EAN-8 expansion and UPC-A standardization.  
Rename “Time Out Control” to “Serial Response Time-out”.  
Rename “Presentation Scanning Mode” to “Presentation Control”.  
Rename “Auto Power Off Duration” to “Light Source On Time”.  
Add “Extremely short” option to Good Read Duration.  
Rev. A3  
Mar 05, 2010  
Page 49  
Rename “Presentation Scanning Auto-sense” to “Presentation Auto-sense”.  
Add “Presentation Sensitivity”  
Page 38  
Page 43  
Hands Free Time-out – Add “Disable”.  
Rev. A4  
Rev. A5  
Apr 27, 2010  
Jun 28, 2010  
Baud Rate – Add 57.6K BPS and 115.2K BPS.  
Page 27  
Page 49  
Page 47  
Page 48  
Add “UPC/EAN Security Level”.  
Add “Time Delay to Low Power Trigger”  
Add “Good Read Indicator”.  
Add “Scan Voting”.  
Page 25,26  
Rename ”Scan Voting” to “Supplement Scan Voting” and add “Supplement  
Scan Voting” in Symbology Reading Control  
Page 27  
Page 38  
Add “EAN Supplement Control”  
Rev. A6  
Sep 20, 2010  
Keyboard Layout – Add “Czech (QWERTY)”, remove “Universal”, and rename  
Spain (QWERTY) to Spain (Spanish QWERTY), Latin America (QWERTY) to  
Spain (Latin America, QWERTY)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Revision History  
Rev. No.  
Rev. A6  
Rev. A7  
Rev. A8  
Rev. A9  
Released Date  
Sep 20, 2010  
Nov 10, 2010  
Jan 2, 2011  
Description  
Page 48  
Page 54  
Remove ”Scan Voting” and add “Scan Rate Control ”  
Add “<Scanned Data><Field Delimiter><Quantity>” parameter selection in Batch Data  
Quantity Output Format.  
Page 44  
Page 47  
Baud Rate – Cancel Baud Rate 300/600 BPS.  
Buzzer Tone Adjust – Modify No power-on beep behavior. The setting of  
No power-on beep will impact both Bluetooth Scanner and Smart Cradle.  
Add “Beeping Control” setting.  
Mar 04, 2011 Page 44  
Baud Rate – Revise 57.6K BPS and 115.2K BPS option code from 6.7. to 8.9.  
Page 23  
Page 45  
Add ”Code 39 Security Level”.  
Add “NAK Retry Count”.  
Rev. B1  
Mar 22, 2011  
Add “ACK/NAK Transmission Indication”.  
Add “Numeric Bar Codes ”.  
Page 69  
Page 73  
Add “Connecting Apple iOS Devices Quick Sets”.  
Page 19, 29, 34, 67 UCC/EAN-128 was renamed GS1-128.  
Page 45  
Page 45  
Rename “ACK/NAK Transmission Indication” to “ACK Indication”.  
Rename the 2 parameters of the “ACK Indication”.  
(Disable  
Disable ACK Time-out Indication, Enable  
Enable ACK Time-out  
Indication)  
Page 45  
Add 2 new parameters to “ACK Indication”.(Disable ACK Indication, Enable  
ACK Indication)  
Rev. B2  
Jul 22, 2011  
Page 47  
Page 47  
Page 54  
Add 6 parameters to “Serial response time -out”. (800 mseconds, 3 seconds, 4  
seconds, 8 seconds, 10 seconds, 15 seconds)  
Cancel the parameter "User defined value (seconds)” of “Serial response time  
-out”.  
Add “Laser Aiming Control” function.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Revision History  
Rev. No.  
Released Date  
Description  
Page 3, 5, 10 “Paging/ Reset button” is changed from 3 seconds to 5 seconds.  
Rev. B3  
Nov 04, 2011  
Page 24  
Add a new function “Codabar Check Digit Settings”  
Page 49  
Page 49  
Cancel 1 parameter of “Code 39/Code 128 Emulation”.(Disable standard code  
39 emulation - -0)  
Change of default setting to Enable standard code 39 skip emulation in “Code  
39/Code 128 Emulation”.  
Rev. B4  
Rev. B5  
Jan 03, 2012  
Mar 05, 2012  
(Disable standard code 39 emulation (0)  
emulation (1))  
Enable standard code 39 skip  
Page 56  
Add 3 new functions:”1D Barcode Forward-reading Indication”, “1D Barcode  
Backward-reading Indication”, “1D Barcode Direction Indication Transmission”  
Download from Www.Somanuals.com. All Manuals Search And Download.  
© Copyright Cino Group  
© Copyright PC Worth Int’l Co., Ltd  
Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of  
merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental  
consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains  
proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied,  
reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written  
permission of Cino. All product information and specifications shown in this document may be changed without prior notice.  
Warranty  
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the  
product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different  
warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident  
or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized  
representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied  
software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but  
not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA  
procedures to return Cino for inspection.  
Regulatory  
FCC part 15B, FCC part 15C  
EN61000-6-2, EN61000-6-3, EN60950-1, EN301 489-1, EN301 489-17, EN300 328  
CNS13438, CNS14336  
AS/NZS CISPR 22:2009 Class B  
LP0002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MIC T401  
LED Eye Safety IEC62471 Exempt group  
Laser Eye Safety IEC60825-1 Class 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Getting Started  
Getting Familiar with Your FuzzyScan  
Preparation before Using  
1
2
Decide Your Radio Link Mode  
Using FuzzyScan in PAIR Mode  
Using FuzzyScan in PICO Mode  
Using FuzzyScan in HID Mode  
Using FuzzyScan in SPP Mode  
3
4
5
7
8
Out-of-range Scanning/Presentation Scanning/Paging Function  
Batch Scanning (Inventory Mode)  
10  
11  
Configure Your FuzzyScan  
Bar Code Programming Manual  
Programming Procedures  
Host Interface Selection  
Symbology Reading Control  
Keyboard Interface Control  
Serial Interface Control  
13  
14  
18  
19  
38  
42  
45  
46  
56  
Wand/Laser Emulation Control  
Operation Control  
Condensed DataWizard  
Appendix  
Symbology ID Table  
63  
64  
65  
66  
67  
68  
69  
70  
Keyboard Function Code Table  
ASCII Input Shortcut  
Link Mode Quick Set/Operation Mode Quick Set  
Host Interface Quick Set  
Option Codes  
System Commands  
Indications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Getting Familiar with Your FuzzyScan  
Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge  
FuzzyScan 2.0 Imaging Technology and Bluetooth 2.1 EDR wireless technology, it not only provides outstanding reading  
performance, but also delivers the convenience and freedom of mobility. This document provides a quick reference for  
installation and operation purposes. The complete documentation is available at www.cino.com.tw.  
F700BT Series Scanner  
HB2110 Smart Cradle (Base)  
Center Indicator  
Side Indicators  
Paging/Reset Button  
Host Interface Port  
DC Power Jack  
Link Indicator  
Status Indicator  
Beeper  
Scan Window  
Trigger  
F600BT Series Scanner  
HB2100 Charging Cradle (Base)  
Reset Button  
Battery Cavity  
End Cap  
Power Indicator  
Reserved  
Reserved  
DC Power Jack  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Preparation before Using  
Install the Battery  
Ensure the battery contacts of the battery pack are facing the charging contacts inside  
the battery cavity.  
Slide the battery pack into the battery cavity until hearing a click sound before locking it  
with the end cap. The scanner will give 4 beeps when the battery pack is installed  
properly if the battery pack still has power.  
Secure the end cap with the screw provided, and make sure the end cap is secured  
properly before using the scanner.  
Charging the Battery  
There are 4 different power plugs in your power supply kit. Choose the appropriate local  
plug and slot it onto the power adapter cavity until it is locked.  
Plug the AC power plug into the appropriate AC wall socket.  
Plug the DC power cord of the power supply unit into the DC power jack of the cradle.  
The smart cradle will issue the power on beeps and the center indicator will give one  
blue blink. If you use the charging cradle, please check the power indicator of the  
charging cradle turns steady blue.  
Place the scanner on the cradle. The status indicator of scanner will turn steady red if  
the battery is not fully charged. When the battery is fully charged, the status indicator of  
scanner will flash green at regular interval.  
Please charge the new battery pack for 8 hours prior to the first use.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Decide Your Radio Link Mode  
The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When  
the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to one connection) or  
PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled IT  
assets. Moreover, you are also able to use the scanner to work with Bluetooth-enabled host devices via SPP master/slave  
modes and HID mode.  
After losing the radio link, the scanner is capable of resuming the radio connection automatically while it returns to the  
communication coverage. But please note that this feature is not available in SPP slave mode. If you would like to change  
the radio link mode, you have to scan the “Uninstall” command to revert the scanner to uninstall state.  
PAIR Mode  
If the Bluetooth device is not available in your existing system, this is the simplest plug-and-play solution. In this mode, one  
scanner can only work with one smart cradle. The smart cradle not only provides the Bluetooth radio link with the scanner,  
but also offers the legacy cabled interfaces to the host device, including USB HID, USB COM, PS/2(DOS/V) Keyboard  
Wedge and RS232 Serial.  
PICO Mode  
For the requirement of multiple connections, up to 7 scanners can be connected to one smart cradle concurrently. If you  
would like to un-pair all paired scanners and smart cradle, you can simply press and hold the paging/reset button of the  
smart cradle for over 5 seconds. If you just want to un-pair part of the paired scanners, please take those paired scanners to  
scan the “Uninstall” command one by one.  
HID Mode  
Through the most helpful HID service, the scanner can work like a Bluetooth keyboard. In this mode, the scanner is  
discoverable by the radio connection request issued by a remote host device. For security purpose, you will be requested to  
input the PIN Code to establish the Bluetooth connection in most time.  
SPP Master/Slave Mode  
Through the standard SPP service, the scanner can work like a serial input device. In SPP master mode, the scanner  
initiates the radio connection request to a remote slave device. In SPP slave mode, the scanner is discoverable by the radio  
connection request issued by a remote master device.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Using FuzzyScan in PAIR Mode  
Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details.  
Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to  
the host device.  
USB  
PS/2  
RS232  
Turn on the power of your host device.  
Please note that the scanner has been pre-paired already, if the scanner is shipped together with the smart cradle. You  
will see the link indicator of scanner gives 1 blue blink per 2.5 seconds and the middle indicator of smart cradle turns  
steady blue. If the scanner and smart cradle just give alternating red and green blinks (in “Uninstall” state), please  
follow steps 5-6 to establish the connection between the scanner and the smart cradle.  
Scan “PAIR mode” command. The status indicator of scanner will turn steady red.  
Uninstall  
PAIR Mode  
Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The  
scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process.  
When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner  
giving 1 blue blink per 2.5 seconds and the center indicator of the smart cradle turning steady blue.  
If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do”  
beeps to indicate pair failure, the scanner will return to uninstall state automatically.  
Scan the corresponding host interface quick set command to complete the installation.  
The default host interface of smart cradle is preset to USB HID. If you want to set the host interface to USB COM, you have to  
install the USB virtual COM driver into your host device before using the scanner. Please visit the CINO website to download  
the software driver.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Using FuzzyScan in PICO Mode  
Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the  
smart cradle and connect it to the host device.  
USB  
PS/2  
RS232  
Turn on the power of your host device.  
Ensure the side indicators of the smart cradle give alternative red and green blinks (in “Uninstall” state). If the smart  
cradle is paired with other scanners, you can press and hold the paging/reset button for over 5 seconds to un-pair all  
paired scanners. Then the smart cradle will return to uninstall state automatically.  
Prepare the scanners you desire to pair with smart cradle. Ensure the status indicator of each scanner give alternative  
red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command to  
un-pair the scanner. Then scan the “PICO mode” command, and the status indicator of scanner will turn steady red.  
Uninstall  
PICO Mode  
Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The  
scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process.  
When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner  
giving 1 blue blink per 2.5 seconds, the center indicator of the smart cradle turning steady blue and its side indicators  
turning steady green.  
If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do”  
beeps to indicate pair failure, the scanner will return to uninstall state automatically.  
Scan the corresponding host interface quick set command to complete the installation.  
Please follow the same procedures to pair the other scanners with the smart cradle.  
For user’s convenience, the smart cradle will automatically assign the ID numbers to each scanner. After completed all  
pairing processes, you can scan the “System Information” command to check the assigned ID number of each scanner.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Clone Function  
For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to  
following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use  
one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration” command.  
After that, please take the other paired scanners to scan “Clone” command one by one to clone the host interface related  
parameters.  
Please ensure to keep those paired scanners in connected status when you use the “Clone” function. Because the host  
interface related parameters can’t be cloned to the paired scanner in disconnected status.  
Save Configuration  
Clone  
The below host interface related parameters will be impacted by clone function:  
Data Transmission Parameter  
Field Delimiter  
Serial Interface Control  
Handshaking Protocol  
Intermessage Delay  
Data Transmission Format  
Host Interface Control  
Interfunction Delay  
Intercharacter Delay  
Host interface Selection  
Keyboard Interface Control  
Keyboard Layout  
Baud Rate  
Data Frame  
Intermessage Delay  
Time Out Control  
Interfunction Delay  
Wand Emulation Control  
Output Polarity  
Intercharacter Delay  
Caps Lock Control  
Initial Signal State  
Margin Time  
Caps Lock Release Control  
Function Key Emulation  
Key Pad Emulation  
Upper/Lower Case  
Module Time  
Narrow/Wide Ratio  
Code39 Emulation  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Using FuzzyScan in HID Mode  
Ensure the battery is fully charged. Power on the scanner within radio range and ensure the status indicator of scanner  
gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the  
“Uninstall” command first. Then scan the “HID Mode” command, and the link indicator of scanner will give 3 blue blinks  
per 2 seconds.  
Uninstall  
HID Mode  
Execute the Bluetooth Discovery procedure to find all available Bluetooth devices in your remote host. You will see ‘’CINO  
FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already.  
Double click the “CINO FxxxBT-xxxx” in the discovered Bluetooth device list. If the PIN Code or Passkey is requested for  
security connection, please enter “00000000” (default setting). You will see “Keyboard on CINO FxxxBT-xxxx”, and  
double click this HID service to establish the connection between the scanner and the remote host device.  
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of  
scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.  
Please note that if the scanner is not connected to the host device within 1 minute after scanning the “HID Mode”  
command, the scanner will go to sleep automatically. You just need to press the trigger to wake up the scanner to  
continue the installation.  
1. The installation procedures vary on different remote host devices, operation systems and the Bluetooth software driver.  
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during  
the installation processes.  
2. While using HID mode, beware of potential error in the data transmitted at the same time when radio link quality is poor.  
You are suggested to use the scanner under the communication coverage all the times.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Using FuzzyScan in SPP Mode  
Establish SPP Master Connection  
Ensure the battery is fully charged. Please go to the folder of “Hardware” located in Bluetooth Advanced Setting of the  
remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host  
device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes.  
Ensure a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of  
Local Services” located in Bluetooth Advanced Setting. Click the “Add Serial Services” to add one more Bluetooth  
COM port.  
Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green  
blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan  
the “SPP Master Mode” command, and the status indicator of scanner will turn steady red.  
Uninstall  
SPP Master Mode  
Scan a 12-character MAC address barcode, or scan 12 option codes and “FIN” command to confirm your inputs. The  
scanner will give continuous short clicks and the link indicator of the scanner will flash blue quickly during the radio  
connecting process. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default  
setting).  
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of  
scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.  
Please note that if the scanner failed to connect to the host device within 30 seconds, the link indicator will give 3 blue  
blinks per 2 seconds. But the scanner is still continuing to discover the host device for another 30 seconds before go to  
sleep. In the interim, you still can scan “Uninstall” command to revert the scanner to uninstall state. If the scanner goes to  
sleep already, you just need to press the trigger to wake up the scanner to continue the installation.  
The installation procedures vary on different remote host devices, operating systems and the Bluetooth software driver.  
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the  
installation processes.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Establish SPP Slave Connection  
Ensure the battery is fully charged and a virtual COM port is available in your remote host for connecting the scanner. If  
not, please go to the folder of “Client Applications” located in Bluetooth Advanced Setting. Click the “Add COM Port” to  
add one more Bluetooth COM port.  
Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green  
blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan  
the “SPP Slave Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds.  
Uninstall  
SPP Slave Mode  
Execute the Bluetooth Discovery procedure to find all available Bluetooth device list in your remote host. You will see  
‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already.  
Double click the “CINO FxxxBT-xxxx” on the discovered Bluetooth devices. If the PIN Code or Passkey is requested for  
security connection, please enter “00000000” (default setting). You will see “Serial Port on CINO FxxxBT-xxxx”, and  
double click this SPP service to establish the connection between the scanner and the remote host device.  
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of  
scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.  
Please note that if the scanner is not connected to the host device within 1 minute, the scanner will go to sleep. You can  
press the trigger to wake up the scanner to continue the installation.  
The installation procedures vary on different remote host devices, operating systems and the Bluetooth software drivers.  
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the  
installation processes.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Out-of-range Scanning  
When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data  
right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio  
connection with the remote host device.  
If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of  
working range. All scanned data will be temporarily stored into the memory buffer until radio link resumed.  
Enable Out-of-range Scannning  
Disable Out-of-range Scanning  
In case of the scanner is out of working range, you will hear 4 beeps in descending tone to indicate the radio connection lost.  
The link indicator of scanner will give 3 blue blinks per 2 seconds. Once the scanner is back to working range, you will hear 4  
beeps in ascending tone to indicate the radio connection rebuilt and the scanner will give 1 blue blink per 2.5 seconds. At the  
same time, all stored scanned data will be transmitted automatically right after the radio link is resumed.  
Presentation Scanning  
The Presentation Scanning is designed for hand-free applications for user’s convenience. If the “Presentation Scanning  
Auto-sense” function is enabled, the scanner is capable of automatically switching to presentation mode when you place it  
onto the SmartStand or cradle.  
Enable Presentation Scanning Auto-sense  
Disable Presentation Scanning Auto-sense  
Paging Function  
The paging function is helpful for you to locate the paired smart cradle or scanner. If you would like to page the paired smart  
cradle, you can scan “Paging” command. If you would like to page the paired scanner, you can press the paging/rest button  
of the smart cradle no longer than 5 seconds.  
Paging  
Paging/Reset Button  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Batch Scanning (Inventory Mode)  
Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000  
EAN-13 labels. It is an ideal cost-saving solution for inventory applications.  
Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into  
the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning. You  
can scan and store the barcode data till the memory storage is full. If the storage is full, you will hear 2 long beeps and the  
status indicator will give 2 red blinks to indicate out of storage. To terminate the batch scanning, please scan the “Exit Batch  
Scanning” command.  
Enter Batch Scanning  
Exit Batching Scanning  
How to Transmit Stored Data  
The scanner is preset to scan the “Transmit Stored Data” command to transmit all stored data. During the transmission  
process, the scanner will give continuous short clicks and blue blinks. Then the scanner will give two short beeps after data  
transmission is completed.  
Transmit Stored Data  
But you are still able to set the scanner to transmit the stored data by placing the scanner onto the cradle as well.  
Transmit Stored Data by Scanning  
Barcode Command  
Transmit Stored Data by Scanning Barcode  
or Placing Scanner onto Cradle  
Transmit Stored Data by  
Placing Scanner onto Cradle  
The scanner is preset to keep all the stored data until you scan the “Clear All Stored Data” command. But you are still able to  
change the setting to “Auto Delete Stored Data after Transmission” as well.  
Clear All Stored Data  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Auto Delete Stored Data  
after Transmission  
Keep Stored Data after  
Transmission  
If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the  
‘’Delete Last Scanned Data’’ command, the last stored data can be deleted.  
Delete Last Scanned Data  
Using Quantity Feature  
If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the  
quantity barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage  
together with the barcode data.  
Quantity 0  
Quantity 1  
Quantity 2  
Quantity 5  
Quantity 6  
Quantity 7  
Quantity 3  
Quantity 4  
Quantity 8  
Quantity 9  
There are two ways to output the stored barcode data and quantity information. Please refer to following for details:  
Stored data is transmitted as many times as the quantity indicated.  
Stored data is transmitted together with quantity information in two fields. Please scan “Enable Quantity Field  
Transmission” command to enable this function. The preset delimiter is “ “, but you are able to choose your desired one  
from FuzzyScan Wireless Reference Manual for details.  
Disable Quantity Field Transmission  
Enable Quantity Field Transmission  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
Bar Code Programming Menu  
The FuzzyScan bar code commands are specially designed  
Proprietary bar code labels which allow you to set the  
FuzzyScan internal programming parameters. There are  
System Command, Family Code and Option Code for  
programming purpose.  
System Command  
The System Command is the highest level bar code  
command which directs FuzzyScan to perform immediate  
operations, such as entering programming mode  
(PROGRAM), exiting programming mode (EXIT), listing  
system information (SYSLIST), recovering to factory  
preset configurations (M_DEFAULT), and so on. Please  
note that all system commands will take a few seconds to  
complete the operations. User must wait for the  
completion beeps before scanning another bar code.  
Each programmable family and bar code command label is  
listed on the same page with major system commands. The  
detailed explanations and special programming flowchart are  
printed on facing or following pages. You can read the  
explanation and set the FuzzyScan concurrently.  
A supplemental bar code command menu incorporates the  
bar code command labels of System Command and Option  
Code. As you set the FuzzyScan, open the bar code  
command menu to find the option code page. You may scan  
the desired family code and option code to set FuzzyScan. If  
you want to change the programming family for multiple  
settings, you need only turn over the programming page to  
find next desired programming family.  
Family Code  
The Family Code is scanned to select the user desired  
programming family. FuzzyScan has already provided  
more than one hundred programming families to meet any  
specific requirements.  
Option Code  
The Option Codes is a set of bar code commands  
represented by “0–9”, “A–F” and finishing selection (FIN).  
For most setting, you must select at least one option code  
following the family code selection to set the desired  
parameter for the selected programming family.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
If the programming family must take multiple scans  
Programming Procedures  
selection, cycling scan selection, or dual level selection  
procedures, the family of the programming menu will be  
marked with the matched representing symbol of  
Programming Category (P.C.) in bold font listed in the  
following table. You can easily find the bold mark in the  
programming menu, and refer to their flowcharts for details.  
Before setting the FuzzyScan, please also refer to the  
“Beeping Indications” listed in Appendix to understand the  
details of programming beeping indications. It will be very  
helpful for you to know the existing status while you are  
programming the FuzzyScan.  
As you scan the bar code command to select the desired  
parameters, information about the final selected parameters  
represented by the bar code commands are stored in the  
FuzzyScan’s internal Flash Memory ASIC or non-volatile  
memory. If you turn off the unit, the Flash Memory ASIC or  
non-volatile memory retains all programming options. You  
need not re-program the FuzzyScan if you want to keep the  
existing configurations in the next power on.  
The programming procedures of FuzzyScan are designed  
as simple as possible for ease of setting. Most  
programming families take the Single Scan Selection  
programming procedure. But several programming families  
have more complex and flexible programmable options,  
and you must take Multiple Scans Selection, Cycling  
Scan Selection or Dual Level Selection to complete their  
programming procedures. Each kind of programming  
procedure is listed in the following pages for your reference.  
Please give careful attention to become familiar with each  
programming procedure.  
Conventions of Programming Menu  
Conventions  
Descriptions  
Factory Default Value  
Programming Category  
P.C.  
SS : Signle scan selection  
MS : Multiple scans selection  
CS : Cycling scan selection  
DS : Dual level scan selection  
(
[
)
]
Necessary Option Code  
Selectable Option Code  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
Program & End  
System List, Group & Master Default  
Scan  
Scan  
SYSLIST  
PROGRAM”  
FuzzyScan will list the product information and  
revision number to host via selected host interface,  
then issue the completion beeping.  
FuzzyScan will enter programming mode,  
and inhibit all non-programming functions.  
Scan  
Scan  
M_DEFAULT”  
END”  
FuzzyScan will recover all programmable  
parameters into factory preset configurations,  
then issue the completion beeping.  
FuzzyScan will exit programming mode, and store all  
parameters in Flash Memory ASIC or non-volatile memory,  
then issue the completion beeping.  
Please note that the FuzzyScan will take 3-4 seconds to  
store parameters in internal Flash Memory ASIC or  
non-volatile memory after you scan the “END”. Please  
don’t turn off the power before the completion beeping. It  
may destroy all configured parameters.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
Single scan selection  
Multiple scans selection  
Scan  
Scan  
Enter programming mode.  
PROGRAM”  
Enter programming mode.  
PROGRAM  
Select one of desired  
programming families.  
Select one of desired  
programming families.  
Scan  
Scan  
One of Family Codes  
One of Family Codes  
1. Select one or several  
option codes to select  
desired parameters.  
Select one option code of  
desired parameter.  
Scan One or  
Scan  
Several Option Codes  
One of Option Codes  
2. If it’s necessary, scan  
“FIN” to terminate  
Yes  
Want to select another  
programming family?  
Yes  
option code selection.  
Repeat  
Repeat  
Selection  
Selection  
Want to select another  
programming family?  
No  
No  
Scan  
Scan  
Exit programming mode.  
Exit programming mode.  
END”  
END  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
Cycling scan selection  
Dual level selection  
Scan  
Scan  
Enter programming mode.  
“PROGRAM”  
Enter programming mode.  
PROGRAM”  
Select one of desired  
programming families.  
Select one of desired  
programming families.  
Scan  
Scan  
One of Family Codes  
One of Family Codes  
Cycling select one or  
several option codes of  
desired parameters as  
“Single” or “Multiple”  
scans selection.  
Select several option codes  
of desired parameters.  
(1st) Scan  
Scan  
Several Option Codes  
One of Option Codes  
1. Select one or several  
option codes of desired  
parameters.  
(2nd) Scan One or  
Scan “FIN”  
Several Option Codes  
2. If it’s necessary, scan  
“FIN” to terminate  
Finish cycling selection.  
(If necessary)  
option code selection.  
Yes  
Yes  
Repeat  
Repeat  
Selection  
Selection  
Want to select another  
programming family?  
Want to select another  
programming family?  
No  
No  
Scan  
Scan  
Exit programming mode.  
Exit programming mode.  
END  
END  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
Host Interface Selection  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Host Interface Selection  
P.C  
Parameter Selection  
Option Code  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
IBM PS/2, 25-30 series keyboard wedge interface  
Standard/TTL RS-232 peer-to-peer serial  
Wand emulation  
02  
06  
08  
09  
10  
13  
14  
17  
18  
19  
USB Com Port Emulation  
PS/2 (DOS/V) direct link (keyboard replacement)  
PS/2 (DOS/V) keyboard wedge turbo mode  
PS/2 (DOS/V) keyboard wedge standard mode  
Laser emulation  
USB HID standard mode  
USB HID turbo mode  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Symbology Reading Control  
User Defined Symbol ID ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Symbol ID : 1 character  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
DS  
Code 128 (default=B)  
GS1-128 (default=C)  
UPC-A (default=A)  
EAN-13 (default=F)  
Codabar/NW-7 (default=D)  
Code 39/Code 32 (default=G)  
Code 93 (default=H)  
Standard/Industrial 2 of 5 (default=I)  
Interleaved 2 of 5 (default=J)  
Matrix 2 of 5 (default=K)  
China Postal Code (default=L)  
German Postal Code (default=M)  
IATA (default=O)  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
26  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
Code 11 (default=P)  
MSI/Plessey (default=R)  
UK/Plessey (default=S)  
Telepen (default=T)  
GS1 DataBar (default=X)  
UPC-E (default=E)  
EAN-8 (default=N)  
Trioptic Code 39 (Default=W)  
UCC Coupon Extended Code (Default=Z)  
PDF417/Micro PDF417 (default=V)  
Codablock F (default=Y)  
Korea Post Code (default =a)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                  
                                                                                                                                                                                             
Configure Your FuzzyScan  
Symbology Reading Control  
Symbology ID Transmission ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable symbology ID transmission  
0
1
2
3
4
5
6
Enable prefix CINO symbology ID transmission  
Enable suffix CINO symbology ID transmission  
Enable both prefix and suffix CINO symbology ID transmission  
Enable prefix AIM symbology ID transmission  
Enable suffix AIM symbology ID transmission  
Enable both prefix and suffix AIM symbology ID transmission  
Symbology ID Transmission  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                    
                                                                                                                                                                                            
Configure Your FuzzyScan  
Symbology Reading Control  
Readable Bar Code Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Readable Symbology Setting  
P.C  
Parameter Selection  
Option Code  
SS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
Auto  
00  
01  
02  
03  
04  
05  
06  
07  
47  
08  
38  
48  
58  
68  
09  
10  
11  
12  
13  
14  
15  
17  
18  
21  
Code 128 *  
UPC-A *  
UPC-E *  
EAN-13 *  
EAN-8 *  
Codabar/NW-7 *  
Code 39 *  
Trioptic Code 39  
Standard/Industrial 2 of 5  
Matrix 2 of 5  
Interleaved 2 of 5 *  
China Postal Code  
German Postal Code  
Code 93 *  
Code 11  
MSI/Plessey  
UK/Plessey  
Telepen  
GS1 DataBar (RSS-14) *  
IATA  
PDF417/Micro PDF417  
Codablock F  
Korea Post Code  
If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add  
the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.  
Above symbologies marketed with * are enable as default. When you select “Auto”, the scanner only read those symbologies marked with *  
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                                  
                                                                                                                                                                                                          
Configure Your FuzzyScan  
Symbology Reading Control  
Code 39/Code 32 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Code 39 Family Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Code 39  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
Enable Code 39  
Select Standard Code 39 as primary format  
Select Full ASCII Code 39 as primary format  
Select Code 32 (PARAF, Italian Pharmaceutical) as primary format  
Disable start/stop symbol transmission  
Enable start/stop symbol transmission  
Disable Code 32 leading A transmission  
Enable Code 32 leading A transmission  
Disable MOD 43 check digit verification  
Enable MOD 43 check digit verification  
Disable check digit transmission  
Enable check digit transmission  
Disable Code 39 buffering  
Enable Code 39 buffering  
SS  
SS  
Disable Trioptic Code 39  
Enable Trioptic Code 39  
0
1
Trioptic Code 39 Setting  
Code 39 Min. Length  
Code 39 Max. Length  
SS  
MS  
Default (01)  
FIN  
(2 digits)  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                                           
                                                                                                                                                                                                 
Configure Your FuzzyScan  
Symbology Reading Control  
Code 39 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Code 39 Security Level  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
Level 0  
Level 1  
Level 2  
Level 3  
0
1
2
3
Code 39 Security Level  
The scanner offers four levels of decode security for Code39 bar codes:  
Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.  
Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.  
Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.  
Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                        
                                                                                                                                                                                        
Configure Your FuzzyScan  
Symbology Reading Control  
Codabar/NW-7 Setting ♦  
PROGRAM  
Family Code Selection  
Codabar Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Codabar  
Enable Codabar  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
Select Codabar standard format  
Select Codabar ABC format  
Select Codabar CLSI format  
Select Codabar CX format  
Disable start/stop symbol transmission  
Enable ABCD/ABCD start/stop symbol transmission  
Enable abcd/abcd start/stop symbol transmission  
Enable ABCD/TN*E start/stop symbol transmission  
Enable abcd/tn*e start/stop symbol transmission  
Disable check digit verification  
Enable check digit verification  
Disable check digit transmission  
Enable check digit transmission  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Modulus 16  
0
1
2
3
4
5
6
Codabar Check Digit Settings  
Modulus 10/weight 3  
Modulus 11  
Modulus 10/weight 2  
7 check DR  
Weight Modulus 11  
Runes (Modulus 10/weight 2)  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Codabar Min. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                        
                                                                                                                                                                                        
Configure Your FuzzyScan  
Symbology Reading Control  
Codabar/NW-7 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Codabar Max. Length  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Symbology Reading Control  
UPC-A & UPC-E Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UPC Family Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable UPC-A  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Enable UPC-A  
Disable UPC-E  
Enable UPC-E  
Disable UPC-E expansion  
Enable UPC-E expansion  
Disable UPC standardization  
Enable UPC standardization  
Disable UPC numeric system  
Enable UPC numeric system  
Disable UPC-A check digit transmission  
Enable UPC-A check digit transmission  
Disable UPC-E check digit transmission  
Enable UPC-E check digit transmission  
Disable UPC “leading 1” portion  
Enable UPC “leading 1” portion  
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric  
system, UPC-A check digit transmission.  
UPC-E & EAN-8 Expansion  
UPC-A/E Standardization  
UPC Lead 1 Numeric System  
: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.  
: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.  
: Enable to read UPC leading with the 1 numeric system, you must enable this option.  
WPC Selection  
(UPC/EAN/CAN)  
Disable  
Check Digit  
Disable  
Numeric System  
With 2-digit  
Addendum  
With 5-digit  
Addendum  
Enable  
Standardization  
Enable  
Expansion  
Basic Length  
UPC-A  
UPC-E  
EAN-13  
EAN-8  
12  
8
13  
8
- 1  
- 1  
- 1  
- 1  
- 1  
- 1  
NC  
NC  
+ 2  
+ 2  
+ 2  
+ 2  
+ 5  
+ 5  
+ 5  
+ 5  
+ 1  
+ 1  
NC  
NC  
0
+ 4  
0
+ 5  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Symbology Reading Control  
UPC-A & UPC-E Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UPC Supplement Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Select UPC without supplement digits  
0
1
2
3
4
5
6
7
Select UPC with only 2 supplement digits  
Select UPC with only 5 supplement digits  
Select UPC with 2/5 supplement digits  
Disable force supplement digits output  
Enable force supplement digits output  
UPC Family Addenda Separator Off  
UPC Family Addenda Separator On  
SS  
SS  
Level 0  
Level 1  
Level 2  
0
1
UPC/EAN Security Level  
Supplement Scan Voting  
SS  
2
Only available for UPC-A & EAN-13  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
None  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
Level 6  
Level 7  
Level 8  
Level 9  
Level 10  
Level 11  
Level 12  
Level 13  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
UPC/EAN Security Level  
The scanner offers three levels of decode security for UPC/EAN bar codes:  
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this  
security level may significantly impair the decoding ability of the scanner.  
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.  
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may  
increase the misread.  
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding  
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5  
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,  
low contrast or damage barcode labels.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                                  
                                                                                                                                                                              
Configure Your FuzzyScan  
Symbology Reading Control  
EAN Setting ♦  
PROGRAM  
Family Code Selection  
EAN Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable EAN-13  
Enable EAN-13  
Disable EAN-8  
0
1
2
3
4
5
6
7
8
9
A
B
Enable EAN-8  
Disable EAN-8 expansion  
Enable EAN-8 expansion  
Disable EAN-13 check digit transmission  
Enable EAN-13 check digit transmission  
Disable EAN-8 check digit transmission  
Enable EAN-8 check digit transmission  
Disable ISBN/ISSN Conversion reading check  
Enable ISBN/ISSN Conversion reading check  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Select EAN without supplement digits  
0
1
2
3
4
5
6
7
EAN Supplement Setting  
Select EAN with only 2 supplement digits  
Select EAN with only 5 supplement digits  
Select EAN with 2/5 supplement digits  
Disable force supplement digits output  
Enable force supplement digits output  
EAN Addenda Separator Off  
EAN Addenda Separator On  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
None  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
Level 6  
Level 7  
Level 8  
Level 9  
Level 10  
Level 11  
Level 12  
Level 13  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
Supplement Scan Voting  
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding  
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5  
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,  
low contrast or damage barcode labels.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                                  
                                                                                                                                                                              
Configure Your FuzzyScan  
Symbology Reading Control  
EAN Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UPC/EAN Security Level  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Level 0  
Level 1  
Level 2  
0
1
SS  
2
Only available for UPC-A & EAN-13  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable all specific prefix supplement digital output  
Enable all specific prefix supplement digital output  
Enable 491 Supplement Digit Output  
Enable 978/979 Supplement Digit Output  
Enable 977 Supplement Digit Output  
Enable 378/379 Supplement Digit Output  
Enable 414/419 Supplement Digit Output  
Enable 434/439 Supplement Digit Output  
0
1
2
3
4
5
6
7
EAN Supplement Control  
UPC/EAN Security Level  
The scanner offers three levels of decode security for UPC/EAN bar codes:  
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this  
security level may significantly impair the decoding ability of the scanner.  
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.  
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may  
increase the misread.  
EAN Supplement Control  
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement  
digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.  
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5  
supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                          
                                                                                                                                                                                                     
Configure Your FuzzyScan  
Symbology Reading Control  
UCC Coupon Extended Code Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UCC Coupon Extended Code  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Disable UCC Coupon Extended Code  
Enable UCC Coupon Extended Code  
0
1
UCC Coupon Extended Code  
When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128  
Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                              
                                                                                                                                                                                                 
Configure Your FuzzyScan  
Symbology Reading Control  
IATA & Interleaved 2 of 5 Setting ♦  
PROGRAM  
Family Code Selection  
IATA Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable IATA  
Enable IATA  
0
1
2
3
4
5
6
7
8
9
A
B
C
Select 15-digit fixed length IATA checking  
Select variable length IATA  
Disable check digit verification  
Enable check digit automatic verification  
Enable S/N checking digit verification only  
Enable CPN checking digit verification only  
Enable CPN, Airline and S/N check digit verification  
Disable check digit transmission  
Enable check digit transmission  
Disable start/stop symbol transmission  
Enable start/stop symbol transmission  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Interleaved 2 of 5  
0
1
2
3
4
5
6
7
8
Interleaved 2 of 5 Setting  
Enable Interleaved 2 of 5  
Select Interleaved 2 of 5 as primary format  
Select German Postal Code as primary format  
No check character  
Validate USS check digit  
Validate OPCC check digit  
Disable check digit transmission  
Enable check digit transmission  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                       
                                                                                                                                                                                        
Configure Your FuzzyScan  
Symbology Reading Control  
Code 25 Family Setting ♦  
PROGRAM  
Family Code Selection  
Code 25 Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Standard/Industrial 2 of 5  
Enable Standard/Industrial 2 of 5  
0
1
2
3
4
5
6
7
8
9
Disable Matrix 2 of 5  
Enable Matrix 2 of 5  
Disable China Postal Code  
Enable China Postal Code  
Disable check digit verification  
Enable check digit verification  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Code 25 Family Min. Length  
Code 25 Family Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length. To decode all types of Code 25 or to variable  
length of Code 25 will increase the possibility of reading error.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                    
                                                                                                                                                                                            
Configure Your FuzzyScan  
Symbology Reading Control  
Code 11 & Code 93 Setting ♦  
PROGRAM  
Family Code Selection  
Code 11 Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Code 11  
Enable Code 11  
0
1
2
3
4
5
6
Disable check digit verification  
Select 1-check digit verification  
Select 2-check digit verification  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Code 11 Min. Length  
Code 11 Max. Length  
Code 93 Setting  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
SS  
SS  
SS  
Disable Code 93  
Enable Code 93  
Disable check digit transmission  
Enable check digit transmission  
0
1
2
3
SS  
MS  
Default (01)  
FIN  
(2 digits)  
Code 93 Min. Length  
Code 93 Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                          
                                                                                                                                                                                     
Configure Your FuzzyScan  
Symbology Reading Control  
MSI/Plessey Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
MSI/Plessey Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable MSI/Plessy  
Enable MSI/Plessy  
0
1
2
3
4
5
6
Select MOD 10 check digit  
Select MOD 10-10 check digit  
Select MOD 11-10 check digit  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
MSI/Plessey Min. Length  
MSI/Plessey Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                             
                                                                                                                                                                                                  
Configure Your FuzzyScan  
Symbology Reading Control  
Code 128 & UCC/EAN 128 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Code 128/EAN-128 Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Code 128 and GS1-128  
0
1
2
3
4
5
Enable Code 128 and GS1-128  
Disable function code conversion  
Enable function code conversion  
ISBT Concatenation Off  
ISBT Concatenation On  
SS  
MS  
Default (01)  
FIN  
(2 digits)  
Code 128/EAN-128 Min. Length  
Code 128/EAN-128 Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                           
                                                                                                                                                                                     
Configure Your FuzzyScan  
Symbology Reading Control  
UK/Plessey Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UK/Plessey Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable UK/Plessey  
Enable UK/Plessey  
0
1
2
3
4
5
6
7
Select UK/Plessey Standard Format  
Select UK/Plessey CLSI Format  
Disable Convert X to A-F  
Enable Convert X to A-F  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
UK/Plessey Min. Length  
UK/Plessey Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                              
                                                                                                                                                                                 
Configure Your FuzzyScan  
Symbology Reading Control  
Telepen Setting ♦  
PROGRAM  
Family Code Selection  
Telepen Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Telepen  
Enable Telepen  
0
1
2
3
4
5
Select Telepen Numeric mode  
Select Telepen Full ASCII mode  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Telepen Min. Length  
Telepen Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                          
                                                                                                                                                                                      
Configure Your FuzzyScan  
Symbology Reading Control  
GS1 DataBar Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
GS1 DataBar Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
Disable GS1 DataBar (RSS-14)  
0
1
2
3
4
5
Enable GS1 DataBar (RSS-14)  
Disable GS1 DataBar Limited  
Enable GS1 DataBar Limited  
Disable GS1 DataBar Expanded  
Enable GS1 DataBar Expanded  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
GS1 DataBar Min. Length  
GS1 DataBar Max. Length  
01-Maximum  
Only available for Expanded GS1 Databar.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (74)  
74-Minimum  
FIN  
(2 digits)  
Only available for Expanded GS1 Databar.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                     
                                                                                                                                                                                                           
Configure Your FuzzyScan  
Symbology Reading Control  
Linear-stacked & Korea Post Code Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Composite Codes Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
Disable composite codes  
Enable composite codes  
0
1
2
3
UPC Composite Mode: UPC never linked  
UPC Composite Mode: UPC always linked  
SS  
SS  
SS  
SS  
Disable PDF417  
Enable PDF417  
Disable MicroPDF417  
Enable MicroPDF417  
0
1
2
3
PDF417/MicroPDF417 Setting  
Codablock F Setting  
SS  
SS  
Disable  
Enable  
0
1
SS  
SS  
Disable  
Enable  
0
1
Korea Post Code Setting  
Length fixed in 6 characters.  
Composite Codes Setting  
If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected.  
If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                          
                                                                                                                                                                                                     
Configure Your FuzzyScan  
Keyboard Interface Control  
Keyboard Layout (Language) Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Keyboard Layout  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
USA (QWERTY)  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
France (AZERTY)  
Germany (QWERTZ)  
United Kingdom - UK (QWERTY)  
Canadian French (QWERTY)  
Spain (Spanish, QWERTY)  
Sweden/Finland (QWERTY)  
Portugal (QWERTY)  
Norway (QWERTY)  
Spain (Latin America, QWERTY)  
Italy (QWERTY)  
Netherlands (QWERTY)  
Denmark (QWERTY)  
Belgium (AZERTY)  
Switzerland-Germany (QWERTY)  
Iceland (QWERTY)  
Japan (DOS/V)  
Czech (QWERTY)  
Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or postamble.  
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.  
Keyboard Interface Message String :  
Preamble  
Data Length  
2-3 digits  
Prefix Symbol ID  
1 or 2 characters  
Scanned Data  
Suffix Symbol ID  
1 or 2 characters  
Postamble  
Record Suffix  
1 character  
1-15 characters  
Variable length  
1-15 characters  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                              
                                                                                                                                                                                                                 
Configure Your FuzzyScan  
Keyboard Interface Control  
Record Suffix, Preamble, Postamble & Caps Lock ♦  
PROGRAM  
Family Code Selection  
Record Suffix  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
None  
RETURN  
TAB  
0
1
2
3
4
SPACE  
ENTER (Numeric Key Pad)  
User defined character (1 character)  
5, (00-7F)  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Preamble  
Postamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
SS  
SS  
“Caps Lock Off” State  
“Caps Lock On” State  
0
1
2
Caps Lock Control  
Caps Lock Release Control  
Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)  
SS  
SS  
“Caps Lock On, Caps Off”  
“Caps Lock On, Shift Off”  
0
1
The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.  
While selecting the other host interfaces, these selections don’t perform the above functions for you.  
Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will  
perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission  
handshaking without changing the status of Caps Lock switch.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                                 
                                                                                                                                                                               
Configure Your FuzzyScan  
Keyboard Interface Control  
Delay Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Intermessage Delay  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x10) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
Intercharacter Delay  
Interfunction Delay  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.  
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data  
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)  
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two  
parameters.  
Interfunction Delay is a time delay between the transmission of each segment of the message string.  
Intermessage Delay, Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                 
                                                                                                                                                                                                               
Configure Your FuzzyScan  
Keyboard Interface Control  
Emulation Setting & Upper/Lower Case Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Function Key Emulation  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Enable ASCII 00-31 code as keyboard function code output  
Ctrl-Output  
0
1
Refer to Appendix – Keyboard Function Code Table for details.  
SS  
SS  
Disable key pad emulation  
0
1
Key Pad Emulation  
Upper/Lower Case  
Enable numeric output as key pad (Num Lock On) output  
SS  
SS  
SS  
SS  
Normal case (neglect the upper/lower case control)  
0
1
2
3
Inverse case (change all characters output to inverse case)  
Upper case (force all characters output as upper case)  
Lower case (force all characters output as lower case)  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                    
                                                                                                                                                                                                            
Configure Your FuzzyScan  
Serial Interface Control  
Record Suffix, Preamble ,Postamble Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
STX/ETX Control  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Disable STX/ETX transmission  
Enable STX/ETX transmission  
0
1
STX/ETX are two characters used to indicate the starting and ending of the total  
data frame transmitted via serial interface.  
SS  
SS  
SS  
SS  
SS  
SS  
MS  
None  
CR (0DH)  
LF (0AH)  
CRLF (0D0AH)  
TAB (09H)  
0
1
2
3
4
5
Record Suffix  
SPACE (20H)  
User defined character (1 character)  
6, (00-7F)  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Preamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Postamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
Serial Interface Message String (RS232, USB COM) :  
STX  
Preamble  
Data Length  
2-3 digits  
Prefix Symbol ID Scanned Data  
Suffix Symbol ID  
Postamble  
ETX  
Record Suffix  
1 character  
1 character  
1-15 characters  
1 or 2 characters Variable length 1 or 2 characters 1-15 characters  
1 character  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                                 
                                                                                                                                                                               
Configure Your FuzzyScan  
Serial Interface Control  
Delay Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Intermessage Delay  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x10) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
Intercharacter Delay  
Interfunction Delay  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.  
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data  
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)  
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two  
parameters.  
Interfunction Delay is a time delay between the transmission of each segment of the message string.  
Intermessage Delay, Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                   
                                                                                                                                                                                            
Configure Your FuzzyScan  
Serial Interface Control  
Protocol, ACK/NAK Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Handshaking Protocol  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
None (free running mode)  
0
1
2
3
RTS/CTS (hardware handshaking)  
ACK/NAK (software handshaking)  
Xon/Xoff (software handshaking)  
SS  
SS  
3 times  
FIN  
(3 digits)  
NAK Retry Count  
ACK Indication  
0~255 times  
SS  
SS  
SS  
SS  
Disable ACK Time-out Indication  
Enable ACK Time-out Indication  
Disable ACK Indication  
Enable ACK Indication  
0
1
2
3
USB COM doesn’t support RTS/CTS handshaking protocol.  
When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after  
each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.  
ACK/NAK handshaking protocol is workable under following conditions:  
1) Pair mode by using RS232 or USB COM interface.  
2) SPP master or slave mode.  
NAK Retry Count  
After transmitting data, the scanner expects a NAK response from the host up to the preset “Serial Response Time-out”. If the scanner doesn’t get a response, the scanner  
will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner  
issues an error indication and discards the data under following two conditions:  
1) After preset NAK retry counts is received within the preset serial response time-out.  
2) If the preset time-out is up but the preset NAK retry counts haven’t come to the end.  
The default retry counts are three times. If you program “0 time”, the scanner won’t resend the data to the host when the scanner receives a NAK. The scanner will discard  
the data. If you program “255 times”, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out.  
This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically.  
ACK Indication:  
Disable: There’s neither LED nor beeping indication for this setting.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
Enable: There’s a specific LED and beeping indication for this setting.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                       
                                                                                                                                                                                                         
Configure Your FuzzyScan  
Serial Interface Control  
Time Out Setting, Baud Rate, Data Frame ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Serial Response Time-out  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
None  
3 seconds  
4 seconds  
5 seconds  
8 seconds  
10 seconds  
15 seconds  
0
1
2
3
4
5
6
7
8
9
A
B
200 mseconds  
500 mseconds  
800 mseconds  
1 second  
2 seconds  
SS  
SS  
SS  
SS  
38.4K BPS  
19.2K BPS  
2400 BPS  
1200 BPS  
57.6K BPS  
115.2K BPS  
0
1
2
3
4
5
8
9
Baud Rate (BPS)  
Data Frame  
9600 BPS  
4800 BPS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
8, None, 1  
8, Odd, 1  
8, Even, 1  
8, Space, 1  
8, Mark, 1  
8, None, 2  
7, Odd, 1  
7, Space, 1  
7, Mark, 1  
7, None, 2  
7, Odd, 2  
7, Even, 2  
7, Space, 2  
7, Mark, 2  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
7, Even, 1  
When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data  
communication. This option is very helpful to ensure the reliability of data communication.  
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                  
                                                                                                                                                                                              
Configure Your FuzzyScan  
Wand/Laser Emulation Control  
Code 39/Code 128 Emulation ♦  
PROGRAM  
Family Code Selection  
Output Polarity  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
High level (5Vdc) on Bar (low level on Space)  
Low level (0Vdc) on Bar (high level on Space)  
0
1
Determine the output voltage level for both bar and space.  
SS  
SS  
High Level (5Vdc)  
Low Level (0Vdc)  
0
1
Initial Signal State  
Margin Time  
Determine the initial state of output voltage level.  
SS  
SS  
SS  
SS  
10 msec.  
15 msec.  
20 msec.  
25 msec.  
30 msec.  
50 msec.  
100 msec.  
Delay time before data transmission  
0
1
2
3
4
5
6
SS  
SS  
SS  
Extremely short  
Short  
Long  
0
1
2
3
Module Time  
Medium  
Time base of minimum narrow bar  
1:2.5  
1:3  
SS  
SS  
SS  
1:2  
0
1
2
Narrow/Wide Ratio  
Code 39/Code 128 Emulation  
SS  
SS  
SS  
SS  
Enable standard Code 39 skip emulation  
1
2
3
4
Enable standard Code 39 replace emulation  
Enable Full ASCII Code 39 emulation  
Enable Code 128 emulation  
[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read,  
they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.  
[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                              
                                                                                                                                                                                  
Configure Your FuzzyScan  
Operation Control  
Operation Mode ♦  
PROGRAM  
Family Code Selection  
Operation Mode  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Trigger mode  
1
2
Presentation mode  
Trigger Mode (Low Power Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the  
scanner before scanning the bar code.  
Presentation Mode (Auto Detection) Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is  
similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work  
properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “ Presentation Sensitivity”).  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                    
                                                                                                                                                                                                            
Configure Your FuzzyScan  
Operation Control  
Buzzer, Indicator, Vibrator, Inverse Reading ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Buzzer Tone Adjust  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Buzzer tone – mute  
Buzzer tone – low  
Buzzer tone – medium  
Buzzer tone – high  
0
1
2
3
4
5
6
Buzzer tone - extremely high  
Power-on beep  
No power-on beep  
SS  
SS  
SS  
Disable (LED off)  
0
1
2
Power On Indicator  
Good Read Indicator  
LED steady on  
LED flash  
SS  
SS  
Disable  
0
1
Enable  
SS  
SS  
Disable  
Enable  
0
1
Vibrator Control  
Inverse Reading  
Beeping Control  
Optional function, only available for vibrator model.  
SS  
SS  
Disable  
Enable  
0
1
SS  
SS  
SS  
SS  
Radio Connected/ Disconnected Beep On  
Radio Connected/ Disconnected Beep Off  
Battery Power Low Beep On  
Battery Power Low Beep Off  
0
1
2
3
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                            
                                                                                                                                                                                                                    
Configure Your FuzzyScan  
Operation Control  
Dollar Sign Control, Redundancy, Scan Rate Control ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Dollar Sign Control  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
Dollar sign output as “ $ “  
0
1
2
3
4
Dollar sign output as “  
Dollar sign output as “ € “  
Dollar sign output as “ £ “  
Dollar sign output as “ ¢ “  
SS  
SS  
SS  
SS  
SS  
SS  
None  
0
1
2
3
4
5
Redundancy  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
To prevent potential miss reading.  
SS  
SS  
Dynamic  
Fixed  
0
1
Scan Rate Control  
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.  
Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on  
the move. But this may impact to the reading distance.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                                 
                                                                                                                                                                               
Configure Your FuzzyScan  
Operation Control  
Delay Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Reread Delay  
(Double Scan Verification)  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
Disable  
0
1
2
3
4
5
Immediate time out  
Short time out  
Medium time out  
Long time out  
Force verification  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
None  
0
1
2
3
4
5
6
Good Read Delay  
200 msec.  
500 msec.  
1 sec.  
1.5 sec.  
2 sec.  
3 sec.  
The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification  
will not allow reading of the same bar code twice.  
This Good Read Delay is the minimum amount of time before the scanner can read another bar code.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                         
                                                                                                                                                                                                       
Configure Your FuzzyScan  
Operation Control  
Time-out Setting, Good Read Duration ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Light Source On Time  
P.C  
Parameter Selection  
Option Code  
Medium  
SS  
SS  
SS  
SS  
Short  
0
1
2
3
Long  
Extremely long  
Medium  
SS  
SS  
SS  
SS  
SS  
Short  
0
1
2
3
4
Hands Free Time-out  
Good Read Duration  
Long  
Extremely long  
Disable  
SS  
SS  
SS  
SS  
SS  
Short  
0
1
2
3
4
Medium  
Long  
Extremely long  
Extremely short  
SS  
SS  
SS  
SS  
SS  
SS  
1 sec  
0
1
2
3
4
5
Time Delay to Low Power Trigger  
3 secs  
5 secs  
7 secs  
9 secs  
Immediate  
The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on  
till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.  
The Presentation Mode is referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode when you press the trigger. You  
can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any trigger operation), the imager will  
revert to the original hands free mode.  
The Time Delay to Low Power Trigger sets the time for scanner to enter low power trigger mode after any scanning activity.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                           
                                                                                                                                                                                                                     
Configure Your FuzzyScan  
Operation Control  
Presentation Scanning Setting, Laser Aiming Control ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
SmartStand Power Off Timeout  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
3 mins  
5 mins  
0
1
2
10 mins  
Only available for FuuzzyScan Laser model  
SS  
SS  
Disable  
Enable  
0
1
Presentation Auto-sense  
Presentation Sensitivity  
Laser Aiming Control  
SS  
SS  
SS  
SS  
SS  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
Level 6  
Level 7  
0
1
2
3
4
5
6
SS  
SS  
Disable  
Enable  
0
1
Only available for L series laser imaging scanner.  
The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed  
on SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will  
be off when the pre-defined duration is up.  
When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the  
SmartStand or cradle.  
The Presentation Sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting  
the barcode.  
You can disable or enable laser aiming line when you scan PDF barcode.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                             
                                                                                                                                                                                                                  
Configure Your FuzzyScan  
Operation Control  
1D Barcode Direction Indication Transmission, etc. ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
None  
“S”  
0
1
1D Barcode Forward-reading  
Indication  
MS  
User defined character(1 character)  
2
2
00-7F  
SS  
SS  
None  
“X”  
0
1D Barcode Backward-reading  
Indication  
1
MS  
User defined character(1 character)  
00-7F  
SS  
SS  
SS  
SS  
Disable  
0
1
2
3
1D Barcode Direction  
Indication Transmission  
Enable prefix direction mark transmission  
Enable suffix direction mark transmission  
Enable both prefix and suffix direction mark transmission  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                
                                                                                                                                                                                                               
Configure Your FuzzyScan  
Operation Control  
Out-of-range Scanning, Sleep Time-out Control ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Out-of-range Scanning  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Disable  
Enable  
0
1
SS  
SS  
SS  
SS  
SS  
1 sec  
0
1
2
3
4
Link Supervision Time-out  
3 secs  
5 secs  
7 secs  
9 secs  
Only available in PAIR & PICO modes  
SS  
MS  
6 (x5) minutes  
FIN  
(2 digits)  
Sleep Time-out of Connect State  
Sleep Time-out of Disconnect State  
0-99 (x5) minutes  
If you don’t want the scanner to enter sleep mode, please set time-out to “0”  
SS  
MS  
1 minute  
FIN  
(2 digits)  
0-99 minutes  
If you don’t want the scanner to enter sleep mode, please set time-out to “0”  
Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode  
data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to  
continue scanning barcode data into memory buffer until radio link resumed.  
The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds.  
The Sleep Time-out Control can be set under radio connection or disconnection state. If the scanner is not used within the preset time-out duration, it will automatically  
enter “Sleep State” for power saving purpose. You are able to disable this function by setting the time-out duration to “0”.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Operation Control  
Batch Scanning Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Batch Scanning Link Control  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Radio disable  
Radio enable  
0
1
SS  
SS  
SS  
All  
0
1
2
Stored Data Transmission  
On cradle  
Scan barcode  
SS  
SS  
Disable  
Enable  
0
1
Delete Stored Data after  
Transmission  
The Batch Scanning Link Control is a pre-defined radio option to control the radio-on or radio-off status under batch scanning operation. Please note that if the radio  
disable is activated, the radio link will be disconnected once you enter batching scanning. The radio link will be resumed when you transmit the stored data or exit batch  
scanning.  
The Stored Data Transmission is a pre-defined approach when you want to transmit the scanned data under batch scanning operation. You can transmit the scanned data  
by placing the scanner onto the cradle or scanning “Transmit Stored Data” command, or by either one of both methods.  
In batching scanning, the default setting of Delete Stored Data after Transmission is disable. The scanner will keep all stored data after transmission until you scan the  
“Clear All Stored Data” command. You are also able to delete all stored data after transmission automatically by enabling this function.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                    
                                                                                                                                                                                                           
Configure Your FuzzyScan  
Operation Control  
Batch Scanning Data Transmission Setting ♦  
PROGRAM  
Family Code Selection  
Field Delimiter  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
None  
SPACE  
0
1
2
3
4
User define  
5, [00-7F]  
SS  
SS  
SS  
As many times as the quantity indicates  
0
1
2
Batch Data Quantity Output Format  
Data Transmission Format  
<Quantity><Field Delimiter><Scanned Data>  
<Scanned Data><Field Delimiter><Quantity>  
SS  
SS  
SS  
Disable (scanned data only)  
0
1
2
Leading with MAC address (MAC address and scanned data)  
Leading with ID No. (scanner ID and scanned data)  
Only available for RS232, USB HID and USB COM interface in PAIR & PICO modes  
The Field Delimiter is used to separate the specific information and scanned data into two fields. You can choose desired delimiter format.  
The Batch Data Quantity Output Format If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the quantity  
barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage together with the barcode data. There are three ways to  
output the stored barcode data and quantity information.  
In PICO mode, up to 7 scanners can be connected with one smart cradle. The Data Transmission Format can help user to identify the source of the transmitted data.  
You can choose to transmit the scanned data leading with MAC address or pre-assigned ID.  
Example format: <MAC address><Field Delimiter><Data> or <ID><Field Delimiter><Data>.  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                      
                                                                                                                                                                                                          
Configure Your FuzzyScan  
Operation Control  
Bluetooth Device Name & Security Setting♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Bluetooth Device Name  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
Default device name  
FIN  
[00-7F], FIN  
User define, 1-16 characters  
SS  
MS  
Default Bluetooth PIN Code  
User define, 1-8 numbers  
FIN  
[30-39], FIN  
Bluetooth PIN Code  
SS  
SS  
Disable  
Enable  
0
1
Bluetooth Authentication  
The default Bluetooth Device Name is “CINO FxxxBT-xxxx”, you will be able to change the device name by scanning HEX values (1-16 characters).  
The default Bluetooth PIN Code is “00000000”, you will be able to change the PIN Code by scanning HEX values (1-8 numbers).  
The Bluetooth Authentication You can enable or disable the Bluetooth Authentication between the scanner and remote host device. If this function is enabled, when the  
scanner wants to connect itself and sends the data to the host device, the host device has to return a link key shared between the scanner and the host device.  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                      
                                                                                                                                                                                          
Configure Your FuzzyScan  
Operation Control  
Bluetooth Other Settings ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
HID Link Quality Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Disable  
Enable  
0
1
SS  
SS  
Disable  
Enable  
0
1
Bluetooth Power Saving Mode  
The HID Link Quality Setting While using the HID radio link mode, some errors may occur during the data transmission when the radio link is disconnected. You can  
enable this function to prevent such error from occurring.  
The Bluetooth Power Saving Mode Bluetooth module will enter low consumption mode when you enable this function.  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                         
                                                                                                                                                                                                                      
Configure Your FuzzyScan  
Condensed DataWizard  
Preamble, Postamble, Data Length & Symbol ID Trans. ♦  
PROGRAM  
Family Code Selection  
Preamble  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Postamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
SS  
Disable  
0
1
Data Length Transmission  
Symbology ID Transmission  
Enable 2 digits data length transmission  
If data length exceeds 99, 3-digit data length will be transmitted.  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable symbology ID transmission  
Enable prefix symbology ID transmission  
Enable suffix symbology ID transmission  
Enable both prefix and suffix symbology ID transmission  
Enable prefix AIM symbology ID transmission  
Enable suffix AIM symbology ID transmission  
Enable both prefix and suffix AIM symbology ID transmission  
0
1
2
3
4
5
6
DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard,  
you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help  
you to arrange the transmission of scanned data to any specific format without software modification.  
Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done  
on-screen, under Windows 95/98/NT/2000/XP environment.  
A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with  
ease.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.  
If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                       
                                                                                                                                                                                       
Configure Your FuzzyScan  
Condensed DataWizard  
Data Formatter Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Formatter Control  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
1st Insertion  
2nd Insertion  
3rd Insertion  
4th Insertion  
[1-3 characters], [FIN]  
[1-3 characters], [FIN]  
[1-3 characters], [FIN]  
2-digits identified position; max. 3 insertion characters  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; max. 3 insertion characters  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; max. 3 insertion characters  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
[1-3 characters], [FIN]  
2-digits identified position; max. 3 insertion characters  
position  
The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code  
symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.  
While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbolology ID or Record  
Suffix. All of the above programmable parameters perform the same function depending on your setting.  
Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 60 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                         
                                                                                                                                                                                     
Configure Your FuzzyScan  
Condensed DataWizard  
Data Verifier Setting ♦  
PROGRAM  
Family Code Selection  
Verifier Control  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
MS  
Disable  
Enable  
FIN  
(2 digits)  
Identified Data Length  
1st Identified Character  
2nd Identified Character  
3rd Identified Character  
Determine the identified data length for verification.  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
[00-7F]  
[00-7F]  
[00-7F]  
2-digits checking position; 1 identified character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits checking position; 1 identified character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits checking position; 1 identified character  
position  
The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.  
All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the  
FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.  
The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.  
Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 60 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                        
                                                                                                                                                                                      
Configure Your FuzzyScan  
Condensed DataWizard  
Data Replacer Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Replacer Control  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
1st Replacement  
2nd Replacement  
3rd Replacement  
[00-7F]  
[00-7F]  
[00-7F]  
2-digits identified position; 1 replacement character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; 1 replacement character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; 1 replacement character  
position  
The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code  
symbologies for replacer control, and provides Multiple Position Replcement in the identified position.  
All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it  
arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.  
Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 60 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find mathced HEX value.  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                       
                                                                                                                                                                                       
Configure Your FuzzyScan  
Condensed DataWizard  
Data Organizer Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Organizer Control  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
1st Organization  
2nd Organization  
0 (Forward)  
1 (Backward)  
2-digits identified position;  
Forward/backward data transmission setting  
position  
direction  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
0 (Forward)  
1 (Backward)  
2-digits identified position;  
Forward/backward data transmission setting  
position  
direction  
SS  
DS  
Transmitted data excluded the data of identified position  
Transmitted data included the data of identified position  
0
1
Include/Exclude Control  
The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code  
symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data  
including or excluding the data of identification position. Please refer to the application example listed in page 60 for details.  
While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record  
Suffix.  
Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 60 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table.  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
[Data Verifier, Data Replacer, Data Organizer]  
Select a Bar Code Symbology  
If there is a 11-character data string, please refer to the  
following to calculate the actual position for identification.  
You can select one or all types of bar code symbologies to  
use Condensed DataWizard for advanced transmission  
arrangement. If you scan “00” to select all types, the  
FuzzyScan will arrange all incoming data to meet your  
pre-defined format. If you want to select only one type bar  
code, please select one of the option code listed below.  
X
X
X
X
X
X
X
X
X
X
X
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
Application Example  
Code 128 : 01  
EAN-8 : 05  
Code 93 : 09  
If your bar code label is a 16-digit Interleaved 2 of 5 which  
includes the information of 6-digit date code, 6-digit serial  
number and 4-digit unit price, you want the FuzzyScan do  
the following for you without software modification:  
UCC/EAN 128 : 31  
UPC-A : 02  
EAN-8 with 2 supple : 35  
EAN-8 with 5 supple.: 45  
Codabar/NW-7 : 06  
Code 39 : 07  
Code 11 : 10  
MSI/Plessey : 11  
UK/Plessey : 12  
Telepen : 13  
UPC-A with 2 supple.: 32  
UPC-A with 5 supple.: 42  
UPC-E : 03  
Code 32 : 37  
GS1 Data Bar : 14  
IATA : 15  
Apply only Interleaved 2 of 5 to the condensed  
UPC-E with 2 supple.: 33  
UPC-E with 5 supple.: 43  
EAN-13 : 04  
Trioptic Code 39: 47  
Matrix 2 of 5 : 38  
Interleaved 2 of 5 : 48  
DataWizard.  
Coupon Code : 16  
PDF417/MicroPDF417: 22  
Codablock: 23  
Check bar code is actually with 16-digit length.  
EAN-13 with 2 supple. : 34 China Postal Code : 58  
EAN-13 with 5 supple. : 44 German Postal Code : 68  
Allow bar code output whose date code is leading with  
Korea Post Code: 26  
“9”.  
Position Calculation  
[Data Formatter]  
Three outputs with “TAB” suffix.  
The date code output should skip “9” and replaced it by  
“A”.  
If there is a 5-character input data string, refer to the following  
to calculate the actual position for insertion:  
The serial number output should be led with “SN”.  
X
X
X
X
X
The unit price output should be skipped the first 2  
00  
01  
02  
03  
04  
05  
digits.  
Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6  
Actual Output : A81025[TAB]SN123456[TAB]76[TAB]  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configure Your FuzzyScan  
Programming Procedure  
[Data Verifier]  
[Data Replacer]  
Scan “Program” to enter the programming mode.  
Scan “Replacer Control” and set bar code symbology  
to “48”.  
Scan “Verifier Control” and set bar code symbology to “48”  
(Interleaved 2 of 5).  
Scan “1st Replacement” and set the identified position  
to “00”, then replaced character to “41” (Hex Code of  
Scan “Identified Data Length” and set the length to “16”.  
A).  
Scan “1st Identified Character” and set the identified  
position to “00”, then set the identified character to “39”  
(Hex Code of 9).  
[Data Organizer]  
Scan “Organizer Control” and set bar code symbology  
to “48”.  
[Data Formatter]  
Scan “1st Organization” and set the identified position  
to “16”, then set the data transmission to “0” (forward).  
Scan “Formatter Control” and set bar code symbology to  
48”.  
Scan “2nd Organization” and set the identified position  
to “17”, then set the data transmission to “1”  
(backward).  
Scan 1st Insertion” and set the identified position to “06”,  
then inserted characters to “09” (Hex Code of TAB), “53”  
(Hex Code of S), “4E” (Hex Code of N).  
Scan “END” (Exit) to terminate the programming.  
Scan “2nd Insertion” and set the identified position to “12”,  
then inserted character to “09”. In the final, you must scan  
FIN” (Finish) code to terminate this selection.  
[Important Notice]  
Scan “3rd Insertion” and set the identified position to “16”,  
then inserted character to “09”. In the final, you must scan  
FIN” (Finish) code to terminate this selection.  
Please note that Condensed DataWizard will follow the  
preset working flow as below:  
Verifier  
Formatter  
Replacer  
Organizer  
So when you set the identified position in Data Organizer,  
you must consider the inserted data which you already set  
via Data Formatter.  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Symbology ID Table  
Each AIM Code Identifier contains the three-character string ]cm where:  
] = Flag Character  
c = Code Character  
m = Modifier Character  
Cino ID  
AIM ID  
Cino ID  
AIM ID  
Code Family  
Primary Format  
Code Family  
Primary Format  
Code  
Code  
Modified  
Code  
Code  
Modified  
Character  
Character  
Character  
Character  
Character  
Character  
UPC-A  
m
1
EAN/JAN-8  
4
1
A
E
N
F
E
UPC-A with 2 supple.  
UPC-A with 5 supple.  
UPC-E  
EAN/JAN-8 with 2 supple.  
EAN/JAN-8 with 5 supple.  
EAN/JAN-13  
2
2
E
m
1
m
1
UPC  
EAN/JAN  
E
UPC-E with 2 supple.  
UPC-E with 5 supple.  
EAN/JAN-13 with 2 supple.  
EAN/JAN-13 with 5 supple.  
2
2
Example: A UPC-A bar code 012345678950 with 2 supplement 12 is  
transmitted as ]E0012345678950]E112  
Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is  
transmitted as ]E449123562]E212345  
Code 128  
B
C
D
I
m
1
Code 93  
Code 93  
H
P
R
S
T
G
H
M
P
m
m
m
0
Code 128  
Codabar  
C
GS1-128  
Code 11  
Code 11  
Codabar/NW-7  
Standard/Industrial 2 of 5  
Matrix 2 of 5  
F
S
X
I
m
0
MSI/Plessey  
UK/Plessey  
Telepen  
MSI/Plessey  
UK/Plessey  
Telepen  
K
J
0
B
m
Interleaved 2 of 5  
m
GS1 DataBar GS1 Databar  
Code 25  
X
e
0
Compsoite  
Composite Code  
Code 39  
China Postal Code  
L
X
0
G
W
G
V
A
X
A
L
m
0
0
0
0
0
Code 39  
German Postal Code  
IATA  
M
O
Z
I
3
Code 39 Trioptic  
Code 32  
IATA  
R
m
UCC Coupon Code  
PDF417  
PDF417/Micro PDF417  
Codablock F  
Example : A UPC-A 512345678900 + GS1-128 81010123451297 bar  
code is transmitted as]E0512345678900]C181010123451297  
Example: A EAN-13 9923456789019 + GS1-128 81010123451297 bar  
code is transmitted as ]E09923456789019]C181010123451297  
Codablock  
Korea Post  
Y
O
X
UCC Coupon  
Korea Post Code  
a
Remark: Above examples are given for the transmission of AIM ID.  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Keyboard Function Code Table  
No.  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
ANSI  
NUL  
SOH  
STX  
ETX  
EOT  
ENQ  
ACK  
BEL  
BS  
ASCII  
00H  
01H  
02H  
03H  
04H  
05H  
06H  
07H  
08H  
09H  
0AH  
0BH  
0CH  
0DH  
0EH  
0FH  
Key Function  
No.  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
ANSI  
DLE  
DC1  
DC2  
DC3  
DC4  
NAK  
SYN  
ETB  
CAN  
EM  
ASCII  
10H  
11H  
Key Function  
RESERVED  
CTRL (Left)  
ALT (Left)  
SHIFT  
F7  
F8  
12H  
13H  
14H  
15H  
16H  
17H  
18H  
19H  
1AH  
1BH  
1CH  
1DH  
1EH  
1FH  
F9  
F10  
F11  
F12  
CAPS LOCK  
NUM LOCK  
ESC  
INS (Insert) (Edit)  
DEL (Delete) (Edit)  
HOME (Edit)  
F1  
BACK SPACE  
HT  
TAB  
END (Edit)  
LF  
F2  
SUB  
ESC  
FS  
PAGE UP (Edit)  
PAGE DOWN (Edit)  
UP (Edit)  
VT  
F3  
12  
13  
14  
15  
FF  
F4  
CR  
ENTER (CR)  
GS  
DOWN (Edit)  
LEFT (Edit)  
SO  
F5  
F6  
RS  
SI  
US  
RIGHT (Edit)  
To emulate the keyboard function key input for user definable parameters, user must configure actual content using the  
Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done  
by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,  
COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
ASCII Input Shortcut  
To configure the user definable parameters of FuzzyScan via  
programming menu, FuzzyScan will ask you to scan your  
desired ASCII value in HEX form. You have to refer to the  
HEX/ASCII Table” for details.  
HEX/ASCII Reference Table  
H
0
1
2
3
4
5
6
7
L
0
1
NUL  
SOH  
STX  
ETX  
EOT  
ENQ  
ACK  
BEL  
BS  
DLE SPACE  
0
1
2
3
4
5
6
7
8
9
:
@
A
B
C
D
E
F
P
Q
R
S
T
U
V
W
X
Y
Z
[
`
a
b
c
d
e
f
p
DC1  
DC2  
DC3  
DC4  
NAK  
SYN  
ETB  
CAN  
EM  
!
"
q
Example:  
2
r
If you want the scanned data output leading with a Dollar  
Sign, you have to set the “Preamble” to “$”. The configuration  
procedure is listed below for reference.  
3
#
$
%
&
'
s
4
t
5
u
Scan the system command – PROGRAM listed on page  
6
v
3-24 to enter programming mode.  
7
G
H
I
g
h
i
w
Scan family code – PREAMBLE to select this family.  
8
(
x
9
HT  
)
y
Refer to the Hex/ASCII Table, you will find the HEX value  
of “$” is 24.  
A
B
C
D
E
F
LF  
SUB  
ESC  
FS  
*
J
j
z
VT  
+
,
;
K
L
k
l
{
Scan the option code – 2 listed on the fold out back cover.  
Scan the option code – 4 listed on the fold out back cover.  
FF  
<
=
>
?
\
|
}
CR  
GS  
-
M
N
O
]
m
n
o
Scan the system command – FIN (Finish) to terminate  
SO  
RS  
.
^
~
Preamble setting.  
SI  
US  
/
_
DEL  
Scan the system command – End to exit the programming  
Example : ASCII “A” HEX “41”; ASCII “a” “61”  
: High Byte of HEX Value  
mode for normal operation.  
: Low Byte of HEX Value  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Numeric Bar Codes  
0
5
6
7
3
4
8
9
1
2
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Link Mode Quick Set  
Uninstall  
SPP Slave Mode  
PAIR Mode  
HID Mode  
SPP Master Mode  
PICO Mode  
Operation Mode Quick Set  
Trigger Mode  
Presentation Mode  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Host Interface Quick Set  
(Work with Smart Cradle only)  
RS232 Serial  
PS/2 (DOS/V) KBW Standard Mode  
USB HID Standard Mode ꢂ  
Keyboard Replacement  
PS/2 (DOS/V) KBW Turbo Mode  
USB HID Turbo Mode  
USB Com Port Emulation  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Option Codes  
0
8
9
4
5
6
7
C
D
E
F
1
2
3
A
B
FIN (Finish)  
END (Exit)  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Connecting Apple iOS Devices Quick Sets  
Enable Variable PIN Code  
Disable Variable PIN Code  
BT PIN Code  
Please refer to Quick Reference Guide of “Connecting FuzzyScan Bluetooth Cordless Scanners with your Apple iOS  
Devices” for more details.  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
System Commands  
PROGRAM  
(Enter Programming Mode)  
Save Configuration  
Sleep  
FIN (Finish)  
Clone  
Paging  
END  
(Exit Programming Mode)  
Factory Default  
PowerTool Host Link  
System Information List  
(SYSLIST)  
Master Default  
Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the  
scanner will revert to uninstall state).  
Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface  
Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), Wand/Laser Emulation Control,  
Bluetooth Device Name, Bluetooth PIN Code, and Out-of-range Scanning, the rest of parameters will be returned to default value (The radio link is still keep  
on).  
Save User Default  
User Default  
User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and  
would like to return to previous setting, please scan “User Default”.  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Indications  
Link Indicator  
Status Indicator  
Descriptions  
Link Indicator  
Beeper  
Radio connected  
1 blue blink per 2.5 sec.  
3 blue blinks per 2 sec.  
Quick blue blinks  
Off  
Radio disconnected  
During connection  
Radio connection built  
Radio connection lost  
Data Transmission  
Off  
Short clicks  
1 blue blink per 2.5 sec.  
3 blue blinks per 2 sec.  
Quick blue blink  
4 beeps in ascending tone  
4 beeps in descending tone  
Short clicks  
Descriptions  
Status Indicator  
Steady red  
Beeper  
Under charging (on cradle)  
Fully charged (on cradle)  
Under batch scanning  
Pair failure  
Off  
1 green blink at regular interval  
Off  
1 green blink per 2.5 sec.  
Off  
Steady red  
2 Di-do Di-do beeps  
2 long beeps  
1 beep at regular interval  
8 beeps  
Out of memory  
2 red blinks  
Battery power low  
Battery power extremely low  
Good read  
1 red blink at regular interval  
8 red blinks  
1 green blink  
1 good read beep  
Off  
Under Configuration  
Uninstall state  
Steady red  
Alternative red and green blinks  
Off  
Upgrade state  
Steady red  
Short click  
3 long beeps  
6 page beeps  
Off  
Time out warning  
Off  
Off  
Off  
Paged by smart cradle  
Sleep state / Battery no power  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Center Indicator  
Side Indicators  
HB2100 Charging Cradle Indication  
Descriptions  
Power  
Beeper  
Power on  
Steady blue  
Off  
HB2110 Smart Cradle Indications  
Indicators  
Descriptions  
Beeper  
Center  
1 blue blink  
Side  
Power on  
Off  
Power on beeps  
Short clicks  
Smart Cradle Upgrade State  
Uninstall state  
Off  
Off  
Steady red  
Alternative red-green blinks Off  
Radio Connected  
Radio Disconnected Off  
Radio Connected Steady blue  
Radio Disconnected Off  
Steady blue  
Steady Green  
Steady red  
Off  
Off  
PICO Mode  
PAIR Mode  
Off  
Off  
Steady red  
Steady green  
Off  
Off  
PICO Mode  
PAIR Mode  
Steady blue  
Steady blue  
6 page beeps  
6 page beeps  
Smart cradle paged  
by scanner  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  

BenQ Computer Monitor T52WA User Manual
Black Box Network Router SCSI Differential Converter User Manual
Black Decker Trimmer 243257 01 User Manual
Blaupunkt Car Stereo System Hollywood C30 User Manual
Blue Rhino Patio Heater 450000 User Manual
Bushnell Hunting Equipment 20 1925 User Manual
Cadillac Automobile 2009 XLR User Manual
Carson Optical Binoculars TZ 401 User Manual
Casio Electronic Keyboard CS 65P User Manual
Chief Manufacturing Indoor Furnishings Projector Ceiling Kit User Manual