O P E R A T I O N
. . . . . . . . .
. . . . . .
. . .
V S E R I E S
V-10S AND V-12S
. . . .
P O W E R E D S U B W O O F E R S
Download from Www.Somanuals.com. All Manuals Search And Download.
I n s t a l l a t i o n
9
POWER: Two-position power switch. In the “ON”mode, the subwoofer’s
PRIOR TO INSTALLATION
amplifier is automatically activated if an audio signal is present and will automatically
become inactive when there is no audio signal present after approximately 30
minutes. In the “OFF”mode, power is shut off to the amplifier.
Carefully unpack your subwoofer, saving the box and all of the packing material; at
some point you may need to transport, ship, or move your subwoofer. Before
continuing with the installation, please make sure the subwoofer is unplugged and
the power switch is turned “OFF.” WARNING: Severe damage may result from
improperly selected voltage. Set voltage selection switch, 10 to the proper AC voltage.
10
VOLTAGE SELECTION: User-switchable voltage selection for use with 115 or 230
volt AC. Attention: All subwoofer models come from the factory preset to
115 volts. To select a different voltage, use a flat head screwdriver to reposition
the switch to the desired voltage. WARNING: Severe damage may result from
improperly selected voltage. Make sure you know the voltage requirement of
the country you are in before attempting to connect this subwoofer to AC
power.
INSTALLATION
Please read the following to determine which installation procedure is best for your
audio/video system. For additional hook-up connections, you may want to refer to
your A/V receiver, processor, preamplifier, or amplifier’s manual. NOTE: Be sure to read
and observe the “Safety Instructions” on preceding page before starting the installation.
11
12
POWER CORD RECEPTACLE: Connect IEC cord to this receptacle (supplied
with the V subwoofer). If the cord supplied does not fit an available AC outlet,
purchase the correct AC cord from your audio dealer or an electrical supply store.
CONTROL DESCRIPTIONS
The following controls are located on the subwoofer’s rear panel, as shown (back cover).
Attention! The Cerwin-Vega V-10S/12S have LFE, LINE-LEVEL, and SPEAKER-
LEVEL input connections; choose one option only for hook-up. Do not hook up
more than one option!
REPLACEABLE FUSE: Protects system from overload, replace with fuse rating as
indicated on amplifier panel at fuse location. The fuse holder is located at the AC
receptacle. Gently pry open to access the fuse.
1
LFE INPUT: Mono “low frequency effects”connection. Use this input if
receiver/preamp/processor has a dedicated LFE or subwoofer OUT. Refer to
the owner’s manual provided by your receiver/preamp/processor manufacturer.
(see figure 1, back cover for hook-up)
PLACEMENT
Your V Series powered subwoofer produces low frequencies which are omnidirectional.
As a result, placement requirements for your subwoofer are flexible and subject to your
listening room’s acoustic characteristics. To determine the best position for your
subwoofer, start by positioning it along the same wall, or plane, as your main speakers.
Experiment with various locations until you find the location that sounds best to you.
Note: Typically, your powered subwoofer will sound louder when placed in close
proximity to walls or corners.
2
3
4
LINE-LEVEL INPUT: Stereo low level input to subwoofer. Connect to “LINE-OUT”,
“MAIN-OUT or PREAMP-OUT”, of your receiver/preamp/processor using a dual RCA
patchcord (not supplied). Refer to the owner’s manual provided by your receiver/
preamp/processor manufacturer. (see figure 2, back cover for hook-up)
SPEAKER-LEVEL INPUT: Stereo high-level inputs to subwoofer. Use these terminals
when line-level connections are not available from A/V receiver/preamp/processor.
Connect to SPEAKER outputs on receiver using high quality speaker wire (16-gauge
or heavier). (see figure 3, back cover for hook-up)
Caution! Cerwin-Vega V-10S and V-12S speakers are intended for FLOOR
PLACEMENT ONLY! Do not place heavy objects of any type, such as televisions on
top of any Cerwin-Vega speaker unless otherwise recommended by Cerwin-Vega!
V Series speakers are for residential applications only.
SPEAKER-LEVEL OUTPUT: Audio loop of stereo high-level (SPEAKER-LEVEL)
3
inputs . Use to loop (continue) signal to speaker connections to the left
and right main speakers.
5
6
VOLUME CONTROL: Controls volume level of subwoofer. Use to balance the output
of the subwoofer with the main speaker output.
CROSSOVER FREQUENCY: The crossover control allows you to adjust the upper
limit of the subwoofer’s frequency response from 40 to 120 Hz. The subwoofer’s
response will begin rolling off above the set frequency. Set the CROSSOVER FRE-
QUENCY to the lower value listed in the main speaker manual.* (Note: Crossover
control does not function when LFE input is used.)
7
8
PHASE: This switch allows you to compensate for having the subwoofer
in a different location than the main speakers. This control allows the signal to be
delayed 180 degrees so the output of the subwoofer will blend in with the
main speakers. Slide the PHASE switch to “180”. At the listening position, listen to
the midbass output. If it sounds weak, set PHASE back to “0.”
POWER LED: Power indicator lamp. Glows green in “ON”mode if audio signal is
present. Glows red in both “OFF”mode and “ON ”mode if receiving AC power,
and if audio signal is not present after approximately 30 minutes.
* Refer to the owner’s manual provided by your main speaker manufacturer to
determine your main speaker’s low end frequency response.
TROUBLESHOOTING
SPECIFICATIONS
V-12S
V-10S
SOLUTION
SYMPTOM
CAUSE
Frequency Response
(+/- 3 dB)
30 Hz - 150 Hz
32 Hz - 150 Hz
Turn down volume control
on subwoofer or lower
receiver level
Bass sounds distorted Subwoofer amplifier has
reached maximum output
Woofer
12” EX™ Woofer
10” EX™ Woofer
Tone controls are set too high
Set bass flat; use controls
sparingly
Amplifier Power
(@0,05% THD)
150 Watts RMS
300 Watts Peak
100 Watts RMS
200 Watts Peak
Repair defective receiver,
preamplifier or replace
speaker wires
Distortion with volume Defective receiver or
control near minimum preamplifier; shorted speaker
wires
Amplifier Features
Variable gain and
Variable gain and
X-O freq.; phase select;
LFE in; line level in; speaker
level in/out; 110/220AC
X-O freq.; phase select;
LFE in; line level in; speaker
level in/out; 110/220AC
Turn down volume control to
lower overall range; use a
more powerful
Distortion on music
peaks or sound
effects
Dynamic soundtrack (e.g.,
explosions)
receiver/amplifier
Protection
AC Fuse & Thermal
No
AC Fuse & Thermal
No
Connect wires only when
audio system power is off
Buzz, hum, or crackle Connecting wires with power
when connecting
wires
on causes transient signal
spikes
Video Shielding
Weight
44lb. / 20kg.
34lb. / 15.6kg.
Check receiver or
Buzz or hum when
system is on
Grounding problem or ground
loop
preamplifier manual for
ground loop elimination
Dimensions
(H x W x D)
(inches)
Turn down volume control
and allow amplifier to cool;
sound should resume
automatically
No sound after
Amplifier’s thermal protection
173⁄4 x 135⁄8 x 193⁄8
45.1x 34.6 x 49.2
161⁄8 x 111⁄2 x 17 3⁄8
41x 29.2 x 44.1
listening at high levels is on
(cm)
Download from Www.Somanuals.com. All Manuals Search And Download.
4
SPEAKER OUT
3
SPEAKER IN
2
LINE LEVELINPUT
1
6
CROSSOVER
FREQUENCY
8
7
PHASE
5
VOLUME
LEFT
LEFT
LFE
+
-
-
+
00
RIGHT
RIGHT
40Hz 120Hz 1800
LOW FREQUENCY EFFECTS CONNECTION
From LFE or Subwoofer Out
Low Frequency Effects Connection
9
POWER
ON
CONFORMS TO
ANSI /UL STD.6500
CERTIFIED TO
12
CAN/CSA STD.E65
10
3007143
CAUTION
RISKOF ELECTRIC
SHOCK DO NOTOPEN
11
AVISRISQUEDE CHOC ELECTRIQUE
NEPASOUVRIR
230
INPUT
VOLTAGE
CAUTION: TO REDUCE
THE RISK OF FIRE,
REPLACE WITH ONLY
THE SAME TYPE AND
RATING OF FUSE.
OFF
ATTENTION: UTILISER
UN FUSIBLE DE
RECHANGE MEME TYPE.
115/230V
60/50Hz 230W
FUSE TYPE:
T1.5AL 250V FOR 230V
T3AL250V FOR115V
ARPL88000
4
SPEAKER OUT
3
SPEAKER IN
2
LINE LEVELINPUT
1
6
8
7
PHASE
5
VOLUME
LEFT
CROSSOVER
FREQUENCY
LEFT
LFE
+
-
-
+
00
RIGHT
Figure 2
RIGHT
40Hz 120Hz 1800
LINE LEVEL CONNECTION
Line Level Out
9
POWER
ON
CONFORMS TO
ANSI /UL STD.6500
CERTIFIED TO
CAN/CSA STD.E65
12
10
3007143
CAUTION
RISKOF ELECTRIC
SHOCK DO NOTOPEN
11
AVISRISQUEDE CHOC ELECTRIQUE
NEPASOUVRIR
230
INPUT
VOLTAGE
CAUTION: TO REDUCE
THE RISK OF FIRE,
REPLACE WITH ONLY
THE SAME TYPE AND
RATING OF FUSE.
OFF
ATTENTION: UTILISER
UN FUSIBLE DE
RECHANGE MEME TYPE.
115/230V
60/50Hz 230W
FUSE TYPE:
T1.5AL 250V FOR 230V
T3AL250V FOR115V
ARPL88000
4
SPEAKER OUT
3
SPEAKER IN
2
LINE LEVELINPUT
1
6
8
7
5
VOLUME
LEFT
CROSSOVER
FREQUENCY
LEFT
LFE
PHASE
+
-
-
+
00
RIGHT
Figure 3
RIGHT
40Hz 120Hz 1800
SPEAKER-LEVEL CONNECTION
From Speaker-Level Out
9
POWER
ON
CONFORMS TO
ANSI /UL STD.6500
CERTIFIED TO
CAN/CSA STD.E65
12
10
3007143
CAUTION
RISKOF ELECTRIC
SHOCK DO NOTOPEN
11
AVISRISQUEDE CHOC ELECTRIQUE
NEPASOUVRIR
230
INPUT
VOLTAGE
CAUTION: TO REDUCE
THE RISK OF FIRE,
REPLACE WITH ONLY
THE SAME TYPE AND
RATING OF FUSE.
OFF
ATTENTION: UTILISER
UN FUSIBLE DE
RECHANGE MEME TYPE.
115/230V
60/50Hz 230W
FUSE TYPE:
T1.5AL 250V FOR 230V
T3AL250V FOR115V
ARPL88000
Download from Www.Somanuals.com. All Manuals Search And Download.
|