| Edition 06/2004   G0301FR0222V01   PROMI 1000   STAND ALONE ACCESS CONTROL SYSTEM   This device comes with a varistor.   The varistor must be connected on the strike terminal (electro-   magnet…) operated by the device.   If this product operates more than one strikes, each of them   should have a varistor.   The varistor controls the overload produced by the strike coil –   back emf.   If you are using a « Shear Lock » electromagnetic lock, it is recommended to use a sepa-   rate power supply than the one connected to the PROMI 1000 !   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   I. PRESENTATION DU PRODUIT   A. Product presentation   - Input voltage 12V AC/DC   - 12-digit keypad with LED visual indicator   - EPROM memory storage   - Date and hour saving with 3V CR2032 battery   - 1000 programmable proximity badges and Pin codes   - 1000 event stored in memory buffer   - Up to 16 holidays   - Removable memory unit   - RS232 output   - Event thermal printing   - Printing of all events and configuration   - Print badge and code list   - Printer with or without DTR signal (MTP640 Kyoline printer recommended)   - Capability to connect an external reader up to 50 meter   - Anti pass back (PROMI 1000 to exit and reader to enter)   - 1 relay output RT contact 3A/125V~   - 1 alarm relay output N/O contact 3A/125V~   - 3 operating modes:   Mode 0: Badge and Pin code   Mode 1: Badge only   Mode 2: Badge or Pin code   - 3 time zones to operate the 3 operating modes   - 5-digit programmable master code   - Proximity readers and keypad lockout during 2 minutes after 3 invalid Pin code badge   - Buzzer for audible signal   - 1 request-to-exit input   - Door contact input   - Minimum distance of 60 cm between the controller and the reader   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   B. Factory Default Values   Operating mode: 0 badge and Pin code   Door open time: 1 second   Alarm time delay: 00 alarm disabled   Key-in keypad time: 10 seconds   Master code: 12345   No time zone   No Holiday   Anti pass back disabled   DTR signal on for printer   Programming time : 2 minuts   C. Audible signals   1 short beep   1 long beep   2 short beeps   4 short beeps   keypad digit key pressed   Access granted or valid data computing   Start or exit from programming or invalid badge read   Error computing data or badge already programmed   D. Visual signals   LED color   En lecture   En programmation   Orange flashing   Orange   Stand-by   Error computing data   Main menu   Green   Red   Access granted   Alarm   Validate computing data   Validate menu   E. Current consumption   200 mA   F. Recommended printer   MTP 640 KYOLINE KYOSHA   Paper: thermal, black printer   width 112 mm   diameter 38 mm   4 Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   reference: TP50XSE2C   RS232 with DTR signal (printer on line)   9600 bauds   1 start   Dip switchs set up on the printer   ON   7 bits   Parity: even   1 stop   1 2 3 4 5 6 7 8   IBM mode   40 characters   CR = skip line   high: printer on line   low: printer off line   DTR signal:   Brown   Green   Terminal   3 White   TX   DT   M 4 5 2 1 RX   Yellow   Back side   Paper error:   When paper roll is finished, the printer LED flashes fast, The data is stored in the memory   buffer of the printer until it is full.   Place another paper roll in the printer and press on the feed button until the paper is placed   properly and put back the top cover of the printer, the LED flashed slowly, press promptly on   the feed paper button, the printer starts printing the data stored in its buffer.   The LED stops flashing.   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   II. PROGRAMMING   A. Colors and audible signals   The letter in bolt represents the LED color.   O2   G1   R1   (O for orange, G for green and R for red)   the digit represents the number of beep emitted.   The LED turns green and the 1 beep is emitted.   The LED turns Red and 1 beep is emitted.   B. Main menu   Important: Refer to the one page programming   Enter the master   Enter the master code twice (12345 default). The LED turns on to orange   and 2 audible beeps are emitted.   code twice   O2   A time delay of 2 minutes is set before the main menu is being shut down.   Once in the main menu, the LED lights on in orange.   R1   Enter the 2-digit number of the menu to select a menu (from 00 to 13 )   Once you enter in the menu, the LED lights in red.   Press on the # to exit from programming.   C. Menu 00 – Program badges and Pin codes   Press 00 to enter in badge & Pin code programming menu. The badges and Pin codes are stored in   a slot (pigeon hole) defined as a user number.   Once in the badge programming menu, an automatic search is launch to select the next available   user number.   G1   Once a free user number is selected the LED lights on in Green   6 Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   O1   --- Present the badge in front of the PROMI1000 or in front the external reader   (nal reader: see Menu 10)   OR   Select a user number, enter the 3-digit user number from 000 to 999   G1   --- If the user number is available the LED lights on in Green   present the badge in front the   PROMI 1000 or in front of the external reader   O1   G1   R1   --- If the user number is not available   delete the badge and Pin code.   enter another user number or press on * twice   to   Then present a badge in front of the PROMI 1000 or external reader.   --------------------------------------------------------------------------------------------------------------------------   O1   --- Enter the 5-digit Pin code   OR   O1   --- Press * to skip the pin code   Another search is launch to select an available user number.   -------------------------------------------------------------------------------------------------------------------------   O4   When all the user numbers are full then the PROMI 1000 displays an error.   -------------------------------------------------------------------------------------------------------------------------   O4   An error is displayed when a badge has been already programmed   -------------------------------------------------------------------------------------------------------------------------   If the printer is connected during the programming then the user number, code of badge and Pin   code are printed.   The last 8-digit of the code of the badge are printed.   D. Menu 01 – Operating mode   Press 01 to enter in the operating mode menu   Press 0 to select Badge & Pin code operating mode.   G1   The LED lights on in green   OR   Press 1 to select badge only operating mode.   G1   The LED lights on in green   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   OR   Press 2 to select badge OR Pin code operating mode.   G1   The LED lights on in green   Press # go   back to MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   E. Menu 02 – Door release time   Enter 02 to enter in the door release time menu   Enter the time in seconds from 01 to 99 for a momentarily output or 00 for a latched output.   G1   The LED lights on in green   Press # go   back to MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   F. Menu 03 – Alarm time output   Enter 03 to enter in the alarm time output menu   Enter the time in seconds per 10 seconds (01 to 99 ) and 00 to disable the alarm.   01 pour 10s et 99 pour 990s.   G1   The LED lights on in green   Press # go   back to MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   G. Menu 04 – Master code   Press 04 to enter in the master code menu   G1   Enter the new 5-digit master code. The LED lights on in green   Press # go   back to MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   8 Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   H. Menu 05 – Setting date and hour   Enter 05 to enter in the date and hour menu   G1   Enter the hour and minutes then the day, month, year and the week day   Week day:   Monday --------- enter 1   Tuesday -------- enter 2   Wednesday --- enter 3   Thursday ------ enter 4   Friday ---------- enter 5   Saturday ------- enter 6   Sunday --------- enter 7   Example: 09h26, 02 September 2003, Tuesday.   Enter 09 26 02 09 03   2 Press # go   back to MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   I. Menu 06 – Schedules   Press 06 to enter in the schedule menu   Each operating mode can be associated with one schedule.   R1   Enter the schedule number of the operating mode   0 for the schedule of the operating mode 0   1 for the schedule of the operating mode 1   2 for the schedule of the operating mode 2   Enter the hour and the minutes for the start time then the hour and the minutes for the stop time   G1   And the week day   Week day: Everyday ---------------- enter 0   Monday ------------------ enter 1   Tuesday ------------------ enter 2   Wednesday ------------- enter 3   Thursday ---------------- enter 4   Friday -------------------- enter 5   Saturday ----------------- enter 6   Sunday ------------------- enter 7   Monday to Friday ------- enter 8   Saturday and Sunday --- enter 9   Example: start time 9h30, stop time 22h50, Monday to Friday.   Enter   09 30   22 50   8 Press # go   back to MENU   O1   Then press#.   The PROMI 1000 returns to the main menu   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   J. Menu 07 – Holidays   Press 07 to enter in the holidays menu   16 different holidays can be programmed, enter the a holiday number from 01 to 16   R1   Then enter the day and month for this holiday   Example: 25 October, enter 25 10   V1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   OR   Enter another holiday.   K. Menu 08 – Anti pass back   Press 08 to enter in the anti pass back menu   Press 0 to deactivate the anti pass back mode. Wait 5 seconds for the complete deactivation.   Press 1 to activate the anti pass back. The PROMI 1000 must be used as the exit reader and the   remote reader as the entry reader.   G1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   L. Menu 09 – Printer and event   Press 09 to enter in the printer setup and event printing menu   R1   R1   Press 0 to delete all the events from the controller   then press # to confirm   wait 15 sec   G1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   OR   G1   G1   Press 1 to print all the events stored in the memory buffer   then press # to confirm   10   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   To stop the printer at any time keep pressing on the 0 key until the LED lights on in green and a   beep is emitted.   At the end of the printing the a message “END PRINTING” appears on the report.   G1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   OR   Press 2 to print the configuration report of the PROMI 1000 control unit.   --------------------------START PRINTING---------------------------   Mod 2   Touv 01s   Talarm 640s   Mait 12345   Mod = Operating mode   Touv = door release time   Talarm = alarm output time   Master = Master Code   DTR off   Pass back on   -------------------------------------------------------------------------   Schedule mode 0   Schedule mode 1   Schedule mode 2   12.56 14.23 0   13.19 15.45 3   19.12 22.47 7   -------------------------------------------------------------------------   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   Holiday   01.01   16.02   01.04   08.05   14.07   15.08   25.10   11.11   31.12   15.12   ----------------------------END PRINTING----------------------------   G1   The LED lights on in green   OR   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   Press 3 to print all the code of badge and Pin code. To abord the printing report, keep pressing on   the 0 key until the LED lights on in green and a beep is emitted.   --------------------------START PRINTING---------------------------   User number Badge   Code   Username   -------------------------------------------------------------------------   000   001   002   003   004   022DC567   023ABD99   023AA1C0   023A9305   02397F8A   12458   54831   89657   55632   --------------------------END PRINTING---------------------------   Only the last 8-digit of the code of the badge are printed on the report.   G1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   OR   Press 4 if the DTR signal is off on the printer.   The LED lights on in gre G1   OR   Press 5 if the DTR signal is on the printer (printer on line)   G1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   M. Menu 10 – Badge enrolment unit   Press 10 to enter in the badge enrolment unit menu   The default badge enrolment unit is the controller built-in reader.   Press 0 to select the controller built-in as the badge enrolment reader, press 1 to select the re-   mote reader as the badge enrolment reader.   12   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   G1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   To program badges and Pin code selec t Menu 00.   The built-in reader of the controller is set back as the default badge enrolment unit once you exit   from programming.   N. Menu 11 Delete schedules   Press 11 to enter in the delete schedule menu   R1   Enter the schedule of the operating mode to delete   0 to delete schedule of operating mode 0   1 to delete schedule of operating mode 1   2 to delete schedule of operating mode 2   G1   Press on * twice to delete the schedule   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   O. Menu 12 – Delete holidays   Press 12 to enter in the delete holiday menu   R1   Enter the holiday number to delete (from 01 to 16 )   G1   Press * twice to delete the holiday. The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   OR   Enter another holiday number.   P. Menu 13 – Setting accesses during the holidays   Press 13 to enter in the setting holiday menu   Enter the user number (000 to 999)   R1   The LED lights on in red   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   Press 1 to authorize the access for the selected user number (cardholder) or press 0 to deny ac-   cess for the selected user number during the holidays.   G1   The LED lights on in green   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   OR   O1   Press * to authorize the access to all the cardholder   Press # to confirm and wait 5s until the new configuration is set for all the cardholder.   V1   The LED lights on in green   OR   O1   Press # to deny access to all the cardholder during the holiday periods   Press # to confirm your choice and wait 5 seconds until the new configuration is set for all the   cardholder.   V1   The green LED lights on   Press # to go back   to the Main MENU   O1   Then press #.   The PROMI 1000 returns to the main menu   Q. Exit from programming   # Exit   O2   You must be in the main menu to exit from programming, press #   Once you exit from programming the PROMI 1000 is on stand-by the LED flashes in orange.   III. OPERATING INSTRUCTIONS   The key-in time between two digit is set at 10 seconds. Behond that time the data computed   is canceled.   A. Reset   Place the ST1 jumper in 2-3 position.   The LED flashes in green during 5 seconds. The default master code is restored to 12345.   14   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   The LED flashes in red and a beep is emitted.   Remove the jumper from 2-3 position then the unit goes back to stand-by mode.   OR   Keep the jumper on 2-3 position to reset the badges, pin codes, schedules and holidays from   the PROMI 1000 memory.   The LED flashes in red during 5 seconds then the LED lights on in red during the reset.   The LED starts flashing in orange when the reset is completed and a beep is emitted.   Remove the jumper from 2-3 position to go back to stand-by mode.   OR   Keep the jumper on 2-3 position to reset the events.   The LED flashes in orange during 5 seconds then lights on in orange during the reset.   The LED lights off when the reset of all the events is completed.   Remove the jumper from 2-3 position to go back to stand-by mode.   B. Operating modes   --- Mode 0 (badge and Pin code)   Present the badge in front of the PROMI 1000 unit. A beep is emitted when the badge is valid.   Enter the 5-digit pin code. If the Pin code is valid the relay is activated and the access is   granted. Two beeps are emitted to indicate that the badge or Pin code are invalid.   --- Mode 1 (badge only)   Present the badge in front of the PROMI 1000 unit. The access is granted if the badge is valid.   Two beeps are emitted to indicate that the badge is invalid.   --- Mode 2 (badge or Pin code)   Present the badge in front of the PROMI 1000 unit. The access is granted if the badge is valid.   Two beeps are emitted to indicate that the badge is invalid.   OR   Enter the 5- digit Pin code. If the Pin code is valid the access is granted.   C. Lockout   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   After 3 incorrect badge and/or PIN code are entered, the PROMI 1000 reader and the second   proximity reader are locked out during 2 minutes and the alarm relay is activated. 2 audible beeps   sound when the badge/PIN code are not valid. The LED lights on in red during the time of the   lockout. The LED flashes in orange when the lockout is finished.   D. Event printing   When a badge is presented or a Pin code is entered, the user number code of badge or Pin Code   date, hour and operating mode are printed.   User number   Mode   Code of badge   Date   Heure   Valid badge   521   Badge 022DC567   25.09.03   17.38   2 Invalid badge   xxx   Badge 0236AD7C   25.09.03   17.40   2 The last 8-digit of the code of the badge are printed.   1000 events are stored in the memory buffer of the controller. The 1001 event replaces the first   one.   E. Door contact - Alarm   The tamper switch activates the relay of the alarm when the front panel is removed. If the alarm   time delay is different to 00, the door monitoring (door ajar or door forced open) is enabled:   When the door is opened, without being activated by the request-to-exit button or a badge, the   alarm relay is activated after 1 second and the red LED lights on (forced open door).   When the badge or the request-to-exit button are used to open a door, if the door stays open, the   open contact will trigger the alarm relay according to the door relay output.   Momentary output   The alarm time delay begins at the end of the door release time. If the door is maintained open   after the alarm time delay, the alarm relay is activated and the red LED lights on. Closing back the   door will deactivate the alarm relay and the LED start flashing orange.   Latched output   The alarm time delay begins only when the door stays open after ordering the closing by present-   ing back the badge or pressing on the request-to-exit button, the alarm relay is activated and the   red LED lights on. Closing back the door will deactivate the alarm relay and the LED flashes or-   ange.   16   Download from Www.Somanuals.com. All Manuals Search And Download.   Edition 10/2003   Note:   1. During an alarm the reader and the request-to-exit are enabled.   2. To cancel the alarm go to Menu 03 in programming and enter 00.   Events   Quand l’alarme est commandée (forced door open, door ajar or lockout alarm) the following   messsages are printed on the event report «Alarm» and «Alarm end» with the day and hour of   the event.   Event   Date   Heure Mode   Alarm   Alarm cleared   25.09.03   25.09.03   17.38   17.44   2 2 F. Memory   The memory unit on the PROMI 1000 can be removed. The time outputs, the schedules, the holi-   day periods, the badges, the Pin codes and the events are stored in the memory unit.   All the data on the memory   G. Anti pass – back   To start the anti passback mode go to menu 08. The PROMI 1000 must used as an exit unit and the   remote reader as the entry reader.   It is important to present the badge on the entry reader and on the exit reader. The access is   granted only when the badge was presented on the exit reader.   H. Setting Date and Hour   The PROMI 1000 has a buit-in clock calender with time and date. The clock must always be   powered by the 12V power supply or the 3V CR1225 battery.   The battery is used only in case of power failure.   Download from Www.Somanuals.com. All Manuals Search And Download.   IV. PROGRAMMING DIAGRAM   PROMI 1000   Key-in programming time: 2minutes and key-in keypad time: 10 seconds, no schedule no holiday   Enter the master   code twice   O2   Present a badge in front of the reader   O1   R1   The PROMI 1000 will search   O1   Press * to skip the Pin   code or enter a 5-digit   O1   00   for the first free user num-   ber   # exit   from   MENU   G1   Free user number   Present badge   G1   O1   Pin code   Or enter a user   number 000 to   999   G1   Press **   R1   Not available   Then enter a user number   Or present a badge   O1   Operating mode   Press 0 for badge and Pin code   Press 1 for badge only   R1   G1   G1   O1   O1   # exit   from   MENU   01   Press 2 for badge or Pin code   R1   R1   # exit   from   MENU   Door release time: Enter 01 to 99 sec. 00 for a latched output   02   03   G1   G1   G1   O1   O1   # exit   from   MENU   Alarm time output per 10 sec.: enter 01 to 99, 00 alarm off   Enter the new 5-digit master code (default 12345)   R1   R1   # exit   from   MENU   04   05   O1   O1   O1   # exit   from   MENU   Date & hour: Enter the hour ans minute then day / month / year and week day   Schedules:   R1   R1   G1   G1   # exit   from   MENU   Enter 0 for mode 0   Enter 1 for mode 1   Enter 2 for mode 2   Hour and minute of start and the hour and minute of stop then the day   Hour and minute of start and the hour and minute of stop then the day   Hour and minute of start and the hour and minute of stop then the day   06   07   R1   # exit   from   MENU   Holiday period: 16 maximum   Enter 01 to 16 then day / month   R1   Download from Www.Somanuals.com. All Manuals Search And Download.   R1   G1   O1   # exit   from   MENU   Anti passback: Enter 1 to enabled   Enter 0 to disabled (resert) wait 5 seconds   08   Printing:   Enter 0 to delete the events   Enter 1 to print all the events   R1   R1   + press #   G1   wait 15 seconds   R1   R1   + press #   (press 0 to stop printing report)   G1   G1   G1   O1   O1   # exit   from   MENU   Enter 2 to print the configuration information of the controller   Enter 3 to print the badge and Pin code list (press 0 to stop the printing report)   Enter 4 set the printer with DTR off   09   10   Enter 5 to set the printer DTR on   # exit   from   MENU   Badge enrolment reader: press 1 to select the remote proximity reader   press 0 to select the PROMI 1000 reader   Delete Schedules:   # exit   from   MENU   G1   G1   O1   O1   R1   R1   Press 0   Press 1   Press 2   to delete the schedule of mode 0 then press * twice   to delete the schedule of mode 1 then press * twice   to delete the schedule of mode 2 then press * twice   11   12   R1   # exit   from   Delete the holiday periods   MENU   R1   Enter 01 to 16   then * twice to delete the holiday   O1   V1   R1   O1   # exit   from   MENU   Press 1 to grant access   Press 0 to deny access   Program holiday period   Enter a user number from 000 to 999   13   O1   O1   Press * to grant access to all the cardholders   Press # - wait 5 seconds   Press # - wait 5 seconds   Press # to deny access to all the cardholders   # Sortie   O2   # Exit   Year format 2-digit   Week days: everyday = 0; Monday = 1; Tuesday = 2 …… Sunday = 7; Monday to Friday = 8 ; Saturday and Sunday = 9   O2   Signalétique   O2   O4   R Orange LED with 2 beeps validate   data computing error   then   Bolt, default values   19   Download from Www.Somanuals.com. All Manuals Search And Download.   V. WIRING DIAGRAM   Reset of master code,   badges, pin codes and   évènts   ST1   ST1 without normal mode   PROMI 1000   Remote reader   60cm   minimum   12   5 2 4 3 1 V ST1   RL1   RL2   2 Input voltage   12VAC/DC   230 V   TX DT M RX 2   1 E M B 3 5 A R C T 12 V   2 Input voltage   12VAC/DC   230 V   230 V   2 Input voltage   12VAC/DC   PB   V Strike   5 The PROMI 1000 and   the remote reader   must be separated   between each other   by 60 cm.   Also, if two PROMI   1000 are installed   next to each other a   distance of 60 cm   must be kept be-   tween   units.   the   two   Download from Www.Somanuals.com. All Manuals Search And Download.   Terminal   Signification   12   V T C R A 5 3 B M Input voltage 12VAC or DC   Input voltage 12VAC or DC   N/O contact   Common contact   N/C contact   N/O alarm contact   Remote reader red LED   Remote reader green LED   Request-to-exit input   Common of Push button and door   contact   E 1 2 RX   M Alarm input   Remote reader data   Remote reader buzzer   RX printer   Common printer   DT   TX   DTR signal printer on line   TX printer   V : Varistor   Download from Www.Somanuals.com. All Manuals Search And Download.   User num-   ber   Badge   Pin Code   Username   Holiday   22   Download from Www.Somanuals.com. All Manuals Search And Download.   VI. TEMPLATE   PROMI1000   23   135   120   Wiring access   Area   105   30 x 40   24   20.5   15   38   61   75.5   Download from Www.Somanuals.com. All Manuals Search And Download.   |