		 Installation   
					Instructions   
					HN-400   
					Barrier-Free Column Shower   
					Table of Contents   
					Pre-Installation Information . . . . . . . . . . . . . . . .2   
					HN-200 Column Shower Components   
					and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .2   
					Installation Instructions   
					Type A Column Shower . . . . . . . . . . . . . . . . . .3   
					Supplies from Below/Vent Off Line   
					Type B Column Shower Installation . . . . . . . .4   
					Supplies from Above/Vent Through Column   
					Type H Column Shower Installation . . . . . . . .5   
					Supplies from Below/Vent Through Column   
					Type O Column Shower Installation . . . . . . . .6   
					Supplies from Above/Vent Off Line   
					Optional Shroud Installation . . . . . . . . . . . . . . . .7   
					Cleaning Instructions . . . . . . . . . . . . . . . . . . . . .9   
					Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9   
					IMPORTANT:   
					Before beginning installation, all supply, drain and waste   
					piping to the shower must be completed according to the   
					rough-ins received with the drain assembly.   
					Check the local codes and ordinances in your area for   
					proper location and connection requirements. Conformity   
					to local codes is the responsibility of the installer.   
					Read and save this installation manual, which contains   
					maintenance and repair information, for future reference.   
					P.O. Box 309, Menomonee Falls, WI 53052-0309   
					TEL: 1-800-BRADLEY FAX: (262) 251-5817   
					
					215-781; Rev. D; EN 03-310   
					© 2003 Bradley Corporation   
					Page 1 of 9   
					12-16-2003   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Barrier-Free Column Shower   
					HN-400   
					Installation Instructions   
					Installation Instructions for Type A HN-400 Column Shower   
					Step 1: Install column shower components   
					NOTE: Flush supply lines before making connections.   
					1. Remove the five bolts that secure the disposable washer to   
					the drain and lift the disposable washer off.   
					2. Bolt the column shower to the drain with the five bolts   
					(removed in procedure #1) and oval washers provided (see   
					Figure 1).   
					(5) 5/16"-18   
					HEX-HEAD   
					BOLTS   
					160-092   
					Step 2: Connect water supply   
					1. Remove the two 1/4"-20 screws from the access panel on   
					the lower body of the column shower and lift the panel off.   
					2. Through the access opening, connect water supplies to the   
					shower’s 3/4" copper tubing as shown in Figure 2 (piping   
					supplied by installer).   
					(5) WASHERS   
					142-034   
					3. Turn on water to the shower and test for leaks and adequate   
					Figure 1   
					water flow.   
					4. Replace the access panel onto the shower with 1/4"-20 screws provided.   
					NOTE: For column shower drains with a dome grate drain, install the two halves of the grate with   
					the screws provided after the column installation is complete.   
					Figure 2   
					Supplies from Below/Vent Off Line   
					Bradley Corporation • 215-781 Rev. D; EN 03-310   
					12-16-2003   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Barrier-Free Column Shower   
					HN-400   
					Installation Instructions   
					Installation Instructions for Type B HN-400 Column Shower   
					Step 1: Install column shower components   
					NOTE: Flush supply lines before making connections.   
					1. Remove the five bolts that secure the disposable washer to   
					the drain and lift the washer off.   
					2. Loosen the screw(s) securing the shower cover and lift the   
					cover off. DO NOT remove the screw(s)!   
					(5) 5/16"-18   
					HEX-HEAD   
					BOLTS   
					3. Insert a 2" NPT vent pipe (supplied by installer) into the shower.   
					160-092   
					NOTE: Make sure that vent pipe does not snag internal wiring or   
					come in contact with electronic components.   
					4. Position the shower over the drain and screw the 2" NPT   
					vent pipe into the vent connection (see Figure 4).   
					5. Bolt the shower to the drain with the five bolts (removed in   
					procedure #1) and oval washers provided (see Figure 1).   
					(5) WASHERS   
					142-034   
					Step 2: Connect water supply   
					Figure 3   
					1. Drop the supplies to the top of the column shower.   
					2. Slide the column cover up the vent and supply piping.   
					NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first,   
					and then slide the column cover up (see page 7 for shroud installation).   
					3. Make supply connections. Supply connection must be made inside the top of the shower so that   
					there is no interference with the piping and the column cover.   
					4. Turn on water to the shower and test for leaks and adequate water flow.   
					5. Secure the column cover with the screws provided.   
					NOTE: For column shower drains with a dome grate drain, install the two halves of grate with the   
					screws provided after column installation is complete.   
					Supplies from Above/Vent Through Column   
					Figure 4   
					4 
					12-16-2003   
					Bradley Corporation • 215-781 Rev. D; EN 03-310   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Barrier-Free Column Shower   
					HN-400   
					Installation Instructions   
					Installation Instructions for Type H HN-400 Column Shower   
					Step 1: Install column shower components   
					NOTE: Flush supply lines before making connections.   
					1. Remove the five bolts that secure the disposable washer to   
					the drain and lift the washer off.   
					2. Loosen the screw(s) securing the shower’s cover and lift the   
					cover off. DO NOT remove the screw(s)!   
					(5) 5/16"-18   
					HEX-HEAD   
					BOLTS   
					3. Insert a 2" NPT vent pipe (supplied by installer) into the shower.   
					160-092   
					NOTE: Make sure that the vent pipe does not snag internal wiring   
					or come in contact with the electronic components.   
					4. Position the shower over the drain and screw the 2" NPT vent   
					pipe into the vent connection (see Figure 6).   
					5. Bolt the shower to the drain with the five bolts (removed in   
					procedure #1) and oval washers provided (see Figure 5).   
					(5) WASHERS   
					142-034   
					Step 2: Connect water supply   
					Figure 5   
					1. Remove the two 1/4"-20 screws from access panel on lower   
					body of column shower and lift panel off.   
					2. Through access opening, connect water supplies to the shower’s 3/4" copper tubing as shown in   
					Figure 6 (piping supplied by installer).   
					3. Slide column cover over vent.   
					NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first,   
					and then slide column cover up (see page 7 for shroud installation).   
					4. Turn on water to the shower and test for leaks and adequate water flow.   
					5. Replace access panel onto shower with the 1/4"-20 screws provided.   
					NOTE: For column shower drains with a dome grate, install the two halves of grate with the screws   
					provided after the column installation is complete.   
					Supplies from Below/Vent Through Column   
					Figure 6   
					Bradley Corporation • 215-781 Rev. D; EN 03-310   
					12-16-2003   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Barrier-Free Column Shower   
					HN-400   
					Installation Instructions   
					Installation Instructions for Type O HN-400 Column Shower   
					Step 1: Install column shower components   
					NOTE: Flush supply lines before making connections.   
					1. Remove the five bolts that secure the disposable washer to   
					the drain and lift the washer off.   
					(5) 5/16"-18   
					HEX-HEAD   
					BOLTS   
					2. Bolt the shower to the drain with the five bolts (removed in   
					procedure #1) and oval washers provided (see Figure 7).   
					160-092   
					3. Loosen the screw(s) securing the shower’s cover and lift the   
					cover off. DO NOT remove the screw(s)!   
					Step 2: Connect water supply   
					1. Drop the supplies to the top of the column shower.   
					2. Slide the column cover up the vent and supply piping.   
					(5) WASHERS   
					142-034   
					NOTE: If you are installing a column shroud, slide the slip ring   
					up the vent and supply piping first, and then slide the column   
					cover up (see page 7 for shroud installation).   
					Figure 7   
					3. Make the supply connections. The supply connection must be   
					made inside the top of the shower so that there is no interference with the piping and the column   
					cover.   
					4. Turn water to the shower on and test for leaks and adequate water flow.   
					5. Secure the column cover with the screws provided.   
					NOTE: For column shower drains with a dome grate, install the two halves of the grate with the   
					screws provided after the column installation is complete.   
					Supplies from Above/Vent Off Line   
					Figure 8   
					6 
					12-16-2003   
					Bradley Corporation • 215-781 Rev. D; EN 03-310   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Barrier-Free Column Shower   
					HN-400   
					Installation Instructions   
					Installation Instructions for Optional   
					Column Shower Shroud   
					NOTE: The column shower must be installed before   
					the shroud. The shroud clips and knock-outs in the   
					column cover must also be prepared. Before making   
					the supply connections, slide the shroud slip ring up   
					the vent and supply piping.   
					SLIP RING   
					S57-020A (12" LONG)   
					S57-141 (7" LONG)   
					(SLIDES INSIDE SHROUD -   
					FASTEN TO CEILING WITH   
					5/16" SCREWS SUPPLIED   
					BY INSTALLER)   
					IMPORTANT: If the shroud is longer than 48"   
					(it has a welded seam rather than a snap   
					together hem) it must also be slid up the vent   
					and supply piping.   
					BOTTOM OF   
					SLIP RING   
					If the supply connections are completed prior to the   
					shroud installation, the supplies will have to be dis-   
					connected in order to slide the slip ring (and shroud if   
					over 48" long) over the vent and piping.   
					Step 3: Preparing the Column Cover   
					1. Remove the column cover from the top of the   
					shower by loosening the screw(s) that secures the   
					column cover retainer.   
					SHROUD   
					(0-48" LENGTHS   
					HAVE HEMMED EDGE)   
					2. Carefully remove the necessary knock-outs from   
					the cover (see Figure 11).   
					(54"-72" LENGTHS   
					HAVE WELDED SEAM)   
					3. Insert the three shroud clips into the locations   
					shown in Figure 11. Snap the clips in place using   
					a flat blade screwdriver.   
					4. Reassemble the cover on shower and proceed   
					with remainder of installation.   
					SCREW   
					160-400   
					Step 4: Complete the Installation   
					1. Make sure the slip ring (and shroud if required)   
					is in place over the vent and supply piping.   
					2. Fasten the slip ring to the ceiling with five 5/16"   
					diameter screws (supplied by installer) (see   
					Figure 10 for screw location dimensions).   
					3. Bring the shroud seam around the vent and sup-   
					ply piping and slide the shroud together (0-48"   
					long shrouds only). Fasten hem together using   
					the supplied #6-32 screws.   
					4. With the column cover in place and the supply   
					connections made, lower the shroud and fasten to   
					the column cover with the #10-24 screws   
					provided (see Figures 9 and 11).   
					Figure 9   
					Bradley Corporation • 215-781 Rev. D; EN 03-310   
					12-16-2003   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Barrier-Free Column Shower   
					HN-400   
					Installation Instructions   
					Installation Instructions .....continued   
					(5) 3/8" DIA.   
					EQUALLY SPACED   
					HOLES   
					7-3/8" DIA   
					BOLT CIRCLE   
					6-3/8" DIA   
					Slip Ring Bolt Pattern   
					Figure 10   
					KNOCK-OUTS   
					SHROUD CLIP   
					#10-24 x 1/2" SCREW   
					160-245 (QTY. 3)   
					159-413   
					(QTY. 3)   
					KNOCK-OUT   
					#10-24 x 3/4" SCREW   
					160-142   
					COLUMN COVER   
					107-062A - 2-5 PERSON   
					107-074A - 6 PERSON   
					RETAINER-COLUMN COVER   
					132-049   
					107-529 - 6 PERSON WITH THERMOBLENDER   
					107-530 - 2-5 PERSON WITH THERMOBLENDER   
					Figure 11   
					8 
					12-16-2003   
					Bradley Corporation • 215-781 Rev. D; EN 03-310   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Barrier-Free Column Shower   
					HN-400   
					Installation Instructions   
					Cleaning Instructions   
					IMPORTANT: Cleanliness is of utmost importance. Do not permit salty solutions to   
					evaporate and dry on stainless steel. Never use ordinary steel wool or   
					steel brushes on stainless steel. Always use stainless steel wool or   
					stainless steel brushes.   
					1. Remove ordinary deposits of dirt and grease with soap and water. Whenever possible, the metal   
					should be thoroughly rinsed and dried after washing.   
					2. Use stainless steel polishing powder to get rid of tightly adhering deposits.   
					3. Look for the source of the rust in some iron or steel not actually a part of the stainless steel struc-   
					ture. Sometimes the appearance of rust streaks on stainless steel leads to the belief that the stain-   
					less steel is rusting. A steel nail or screw may be the cause of the trouble.   
					4. If the showerhead delivers an uneven spray, remove the showerhead from the unit, disassemble,   
					and remove foreign matter.   
					5. Reassemble showerhead and reinstall into unit.   
					HN-400 Column Shower Warranty   
					Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in   
					material and workmanship under normal use and service upon the following terms and conditions:   
					1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the   
					purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within   
					the limitations of this warranty.   
					2. The period during which Column Shower components are warranted is one (1) year, measured from the   
					date of our invoice.   
					3. This warranty does not cover installation or any other labor charges and does not apply to any units   
					which have been damaged by accident, abuse, improper installation or improper maintenance.   
					4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of   
					the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation   
					shall not otherwise be liable under any circumstances for incidental, consequential or indirect damages   
					caused by defects in the repair or replacement thereof.   
					5. This warranty extends only to commercial and institutional purchasers and does not extend to any others,   
					including consumer customers of commercial and institutional purchasers.   
					6. This warranty is in lieu of all other warranties, express or implied, including any implied warranty of   
					merchantability or fitness for a particular purpose or otherwise.   
					Bradley Corporation • 215-781 Rev. D; EN 03-310   
					12-16-2003   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |