Table of Contents  
Safety  
Safety precautions  
Important safety instructions  
Important Notices  
FCC & ICES compliance  
UL certification  
Bosch notices  
Installation  
Tools required  
Opening the side covers  
Mount the unit  
Connecting the input cable  
Connecting the output cables  
Technical Data  
Specifications  
Dimensions  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
en | Safety  
Power Supply  
1
Safety  
1.1  
Safety precautions  
DANGER!  
High risk: This symbol indicates an imminently hazardous  
situation such as "Dangerous Voltage" inside the product.  
If not avoided, this will result in an electrical shock, serious  
bodily injury, or death.  
WARNING!  
Medium risk: Indicates a potentially hazardous situation.  
If not avoided, this could result in minor or moderate bodily  
injury.  
CAUTION!  
Low risk: Indicates a potentially hazardous situation.  
If not avoided, this could result in property damage or risk of  
damage to the unit.  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Power Supply  
Safety | en  
5
1.2  
Important safety instructions  
Read, follow, and retain for future reference all of the following  
safety instructions. Heed all warnings on the unit and in the  
operating instructions before operating the unit.  
1. Cleaning - Unplug the unit from the outlet before cleaning.  
Follow any instructions provided with the unit. Generally,  
using a dry cloth for cleaning is sufficient but a moist, fluff-  
free cloth or leather shammy may also be used. Do not use  
liquid cleaners or aerosol cleaners.  
2. Heat Sources - Do not install the unit near any heat  
sources such as radiators, heaters, stoves, or other  
equipment (including amplifiers) that produce heat.  
3. Ventilation - Any openings in the unit enclosure are  
provided for ventilation to prevent overheating and ensure  
reliable operation. Do not block or cover these openings.  
Do not place the unit in an enclosure unless proper  
ventilation is provided, or the manufacturer's instructions  
have been adhered to.  
4. Water - Do not use this unit near water, for example near a  
bathtub, washbowl, sink, laundry basket, in a damp or wet  
basement, near a swimming pool, in an outdoor  
installation, or in any area classified as a wet location. To  
reduce the risk of fire or electrical shock, do not expose  
this unit to rain or moisture.  
5. Object and liquid entry - Never push objects of any kind  
into this unit through openings as they may touch  
dangerous voltage points or short-out parts that could  
result in a fire or electrical shock. Never spill liquid of any  
kind on the unit. Do not place objects filled with liquids,  
such as vases or cups, on the unit.  
6. Lightning - For added protection during a lightning storm,  
or when leaving this unit unattended and unused for long  
periods, unplug the unit from the wall outlet and  
disconnect the cable system. This will prevent damage to  
the unit from lightning and power line surges.  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
en | Safety  
Power Supply  
7. Controls adjustment - Adjust only those controls specified  
in the operating instructions. Improper adjustment of  
other controls may cause damage to the unit. Use of  
controls or adjustments, or performance of procedures  
other than those specified, may result in hazardous  
radiation exposure.  
8. Overloading - Do not overload outlets and extension cords.  
This can cause fire or electrical shock.  
9. Power cord and plug protection - Protect the plug and  
power cord from foot traffic, being pinched by items  
placed upon or against them at electrical outlets, and its  
exit from the unit. For units intended to operate with  
230 VAC, 50 Hz, the input and output power cord must  
comply with the latest versions of IEC Publication 227 or  
IEC Publication 245.  
10. Power disconnect - Units have power supplied to the unit  
whenever the power cord is inserted into the power  
source. The power cord plug is the main power disconnect  
device for switching off the voltage for all units.  
11. Power sources - Operate the unit only from the type of  
power source indicated on the label. Before proceeding,  
be sure to disconnect the power from the cable to be  
installed into the unit.  
For battery powered units, refer to the operating  
instructions.  
For external power supplied units, use only the  
recommended or approved power supplies.  
For limited power source units, this power source  
must comply with EN60950. Substitutions may  
damage the unit or cause fire or shock.  
For 24 VAC units, voltage applied to the unit's power  
input should not exceed 10%, or 28 VAC. User-  
supplied wiring must comply with local electrical  
codes (Class 2 power levels). Do not ground the  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Supply  
Safety | en  
7
supply at the terminals or at the unit's power supply  
terminals.  
If unsure of the type of power supply to use, contact  
your dealer or local power company.  
12. Servicing - Do not attempt to service this unit yourself.  
Opening or removing covers may expose you to dangerous  
voltage or other hazards. Refer all servicing to qualified  
service personnel.  
13. Damage requiring service - Unplug the unit from the main  
AC power source and refer servicing to qualified service  
personnel when any damage to the equipment has  
occurred, such as:  
the power supply cord or plug is damaged;  
exposure to moisture, water, and/or inclement  
weather (rain, snow, etc.);  
liquid has been spilled in or on the equipment;  
an object has fallen into the unit;  
unit has been dropped or the unit cabinet is damaged;  
unit exhibits a distinct change in performance;  
unit does not operate normally when the user  
correctly follows the operating instructions.  
14. Replacement parts - Be sure the service technician uses  
replacement parts specified by the manufacturer, or that  
have the same characteristics as the original parts.  
Unauthorized substitutions may cause fire, electrical  
shock, or other hazards.  
15. Safety check - Safety checks should be performed upon  
completion of service or repairs to the unit to ensure  
proper operating condition.  
16. Installation - Install in accordance with the manufacturer's  
instructions and in accordance with applicable local codes.  
17. Attachments, changes or modifications - Only use  
attachments/accessories specified by the manufacturer.  
Any change or modification of the equipment, not  
expressly approved by Bosch, could void the warranty or,  
in the case of an authorization agreement, authority to  
operate the equipment.  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
en | Safety  
Power Supply  
1.3  
Important Notices  
All-pole power switch - Incorporate an all-pole power switch,  
with a contact separation of at least 3 mm in each pole, into the  
electrical installation.If it is needed to open the housing for  
servicing and/or other activities, use this all-pole switch as the  
main disconnect device for switching off the voltage to the unit.  
Environmental statement - Bosch has a strong commitment  
towards the environment. This unit has been designed to  
respect the environment as much as possible.  
Fuse rating - For protection of the device, the branch circuit  
protection must be secured with a maximum fuse rating of 16A.  
This must be in accordance with NEC800 (CEC Section 60).  
Grounding and polarization - This unit may be equipped with a  
polarized alternating current line plug (a plug with one blade  
wider than the other blade). This safety feature allows the plug  
to fit into the power outlet in only one way. If unable to insert  
the plug fully into the outlet, contact a locally certified  
electrician to replace the obsolete outlet. Do not defeat the  
safety purpose of the polarized plug.  
Alternately, this unit may be equipped with a 3-pole grounding  
plug (a plug with a third pin for earth grounding). This safety  
feature allows the plug to fit into a grounded power outlet only.  
If unable to insert the plug into the outlet, contact a locally  
certified electrician to replace the obsolete outlet. Do not  
defeat the safety purpose of the grounding plug.  
Moving - Disconnect the power before moving the unit. Move  
the unit with care. Excessive force or shock may damage the  
unit.  
Outdoor signals - The installation for outdoor signals, especially  
regarding clearance from power and lightning conductors and  
transient protection, must be in accordance with NEC725 and  
NEC800 (CEC Rule 16-224 and CEC Section 60).  
Permanently connected equipment - Incorporate a readily  
accessible disconnect device external to the equipment.  
Pluggable equipment - Install the socket outlet near the  
equipment so it is easily accessible.  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Supply  
Safety | en  
9
1.4  
FCC & ICES compliance  
FCC & ICES Information  
(U.S.A. and Canadian Models Only)  
This equipment has been tested and found to comply with the  
limits for a Class B digital device, pursuant to part 15 of the  
FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential  
installation. This equipment generates, uses, and can radiate  
radio frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular  
installation. If this equipment does cause harmful interference  
to radio or television reception, which can be determined by  
turning the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following  
measures:  
reorient or relocate the receiving antenna;  
increase the separation between the equipment and  
receiver;  
connect the equipment into an outlet on a circuit different  
from that to which the receiver is connected;  
consult the dealer or an experienced radio/TV technician  
for help.  
Intentional or unintentional modifications, not expressly  
approved by the party responsible for compliance, shall not be  
made. Any such modifications could void the user's authority to  
operate the equipment. If necessary, the user should consult  
the dealer or an experienced radio/television technician for  
corrective action.  
The user may find the following booklet, prepared by the  
Federal Communications Commission, helpful: How to Identify  
and Resolve Radio-TV Interference Problems. This booklet is  
available from the U.S. Government Printing Office,  
Washington, DC 20402, Stock No. 004-000-00345-4.  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10 en | Safety  
Power Supply  
Informations FCC et ICES  
(modèles utilisés aux États-Unis et au Canada uniquement)  
Suite à différents tests, cet appareil s'est révélé conforme aux  
exigences imposées aux appareils numériques de classe B, en  
vertu de la section 15 du règlement de la Commission fédérale  
des communications des États-Unis (FCC), et en vertu de la  
norme ICES-003 d'Industrie Canada. Ces exigences visent à  
fournir une protection raisonnable contre les interférences  
nuisibles lorsque l'appareil est utilisé dans le cadre d'une  
installation résidentielle. Cet appareil génère, utilise et émet  
de l'énergie de radiofréquences et peut, en cas d'installation ou  
d'utilisation non conforme aux instructions, engendrer des  
interférences nuisibles au niveau des radiocommunications.  
Toutefois, rien ne garantit l'absence d'interférences dans une  
installation particulière. Il est possible de déterminer la  
production d'interférences en mettant l'appareil  
successivement hors et sous tension, tout en contrôlant la  
réception radio ou télévision. L'utilisateur peut parvenir à  
éliminer les interférences éventuelles en prenant une ou  
plusieurs des mesures suivantes:  
Modifier l'orientation ou l'emplacement de l'antenne  
réceptrice;  
Éloigner l'appareil du récepteur;  
Brancher l'appareil sur une prise située sur un circuit  
différent de celui du récepteur;  
Consulter le revendeur ou un technicien qualifié en radio/  
télévision pour obtenir de l'aide.  
Toute modification apportée au produit, non expressément  
approuvée par la partie responsable de l'appareil, est  
strictement interdite. Une telle modification est susceptible  
d'entraîner la révocation du droit d'utilisation de l'appareil.  
La brochure suivante, publiée par la Commission fédérale des  
communications (FCC), peut s'avérer utile : How to Identify and  
Resolve Radio-TV Interference Problems (Comment identifier et  
résoudre les problèmes d’interférences de radio et de télévision).  
Cette brochure est disponible auprès du U.S. Government  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Supply  
Safety | en 11  
Printing Office, Washington, DC 20402, États-Unis, sous la  
référence n° 004-000-00345-4.  
1.5  
UL certification  
Disclaimer  
Underwriter Laboratories Inc. ("UL") has not tested the  
performance or reliability of the security or signaling aspects of  
this product. UL has only tested fire, shock and/or casualty  
hazards as outlined in UL's Standard(s) for Safety for Closed  
Circuit Television Equipment, UL 2044. UL Certification does not  
cover the performance or reliability of the security or signaling  
aspects of this product.  
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR  
CERTIFICATIONS WHATSOEVER REGARDING THE  
PERFORMANCE OR RELIABILITY OF ANY SECURITY OR  
SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.  
Disclaimer  
Underwriter Laboratories Inc. ("UL") has not tested the  
performance or reliability of the security or signaling aspects of  
this product. UL has only tested fire, shock and/or casualty  
hazards as outlined in UL's Standard(s) for Safety for Information  
Technology Equipment, UL 60950-1. UL Certification does not  
cover the performance or reliability of the security or signaling  
aspects of this product.  
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR  
CERTIFICATIONS WHATSOEVER REGARDING THE  
PERFORMANCE OR RELIABILITY OF ANY SECURITY OR  
SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT.  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
12 en | Safety  
Power Supply  
1.6  
Bosch notices  
Disposal - Your Bosch product was developed and  
manufactured with high-quality material and components that  
can be recycled and reused. This symbol means that  
electronic and electrical appliances, which have reached the  
end of their working life, must be collected and disposed of  
separately from household waste material. Separate collecting  
systems are usually in place for disused electronic and  
electrical products. Please dispose of these units at an  
environmentally compatible recycling facility, per European  
Directive 2002/96/EC  
Copyright  
This manual is the intellectual property of Bosch Security  
Systems and is protected by copyright.  
All rights reserved.  
Trademarks  
All hardware and software product names used in this  
document are likely to be registered trademarks and must be  
treated accordingly.  
NOTE:  
This manual has been compiled with great care and the  
information it contains has been thoroughly verified. The text  
was complete and correct at the time of printing. The ongoing  
development of the products may mean that the content of the  
user guide can change without notice. Bosch Security Systems  
accepts no liability for damage resulting directly or indirectly  
from faults, incompleteness or discrepancies between the user  
guide and the product described.  
More information  
For more information please contact the nearest Bosch Security  
Systems location or visit www.boschsecurity.com  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Supply  
Installation | en 13  
2
Installation  
CAUTION!  
Installation should only be performed by qualified service  
personnel in accordance with the National Electrical Code or  
applicable local codes.  
Disconnect the supply power before installing  
2.1  
2.2  
Tools required  
Small flat blade screwdriver.  
Crosshead screwdriver.  
Wire cutter/stripper tool.  
Opening the side covers  
Figure 2.1 Removing side covers  
Unscrew the four cross-head screws at each corner and remove  
each of the side covers.  
2.3  
Mount the unit  
Figure 2.2 Mounting the unit  
Secure the unit to a flat surface using mounting screws (not  
supplied) in the four holes (4 mm) shown in the figure.  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
14 en | Installation  
Power Supply  
2.4  
Connecting the input cable  
5 mm  
(0.2 in)  
Input  
110-230 VAC  
50/60 Hz  
Neutral In  
Live In  
Earth In  
Figure 2.3 Connecting the input cable  
Connect input supply cable as follows:  
Cut back the insulation of the cable wires to approximately  
5 mm (0.2 in).  
Pass the input cable through the supplied grommet.  
For each wire, push back the tab behind the terminal with  
a small screwdriver and insert the wire (respect the  
polarity shown in the figure); release the tab to clamp the  
wire in place.  
Secure the grommet firmly.  
Return the protective cover to its position and fasten in  
place with the four cross-head screws.  
Note:  
Tighten screws firmly to ensure protection against water  
ingress.  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Supply  
Installation | en 15  
2.5  
Connecting the output cables  
5 mm  
(0.2 in)  
Figure 2.4 Connecting the output cables  
Connect the two output cables as follows:  
Cut back the insulation of the cable wires to approximately  
5 mm (0.2 in).  
Pass the output cables through the supplied grommets.  
For each wire, push back the tab behind the terminal with  
a small screwdriver and insert the wire (respect the  
polarity shown in the figure); release the tab to clamp the  
wire in place.  
Secure the grommets firmly.  
Return the protective cover to its position and fasten in  
place with the four cross-head screws.  
Note:  
Tighten screws firmly to ensure protection against water  
ingress.  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
16 en | Technical Data  
Power Supply  
3
Technical Data  
3.1  
Specifications  
Model  
PSU-224-DC100  
Output  
DC voltage  
24 VDC  
4.0 A  
Rated current  
Rated power  
96 W (total both  
outputs)  
Input  
Voltage range  
Frequency range  
AC current  
100 to 240 VAC  
50 to 60 Hz  
1.5 A (115 VAC)  
0.5 A (230 VAC)  
Construction  
Weight  
1.25 kg  
Material  
Casing: Aluminum  
extrusion;  
End-caps: mild steel.  
Finish  
Powder coated paint  
RAL 9010 (Pure White)  
Cable glands  
Suitable for cable  
diameter 4 to 8 mm  
Environment  
Water protection  
IP66  
Working temperature -30 to +50°C  
Working humidity 20 to 95% RH non-  
condensing  
Storage temperature -40 to +80°C  
Storage humidity  
10 to 95% RH non-  
condensing  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Power Supply  
Technical Data | en 17  
Safety &  
EMC  
Safety standards  
Harmonic current  
EN60950-1UL60950-  
1EN60950-22, IP66  
Compliance to Class C  
(less than 75% load);  
EN61000-3-3  
EMS immunity  
Compliance to  
EN61000-4-  
2,3,4,5,6,8,11;  
ENV50204, EN55024,  
EN61547, light industry  
level (surge 4KV),  
criteria A  
3.1.1  
Dimensions  
199 (7.84)  
224 (8.8)  
266 (10.47)  
mm (in)  
Figure 3.1 Dimensions  
Bosch Security Systems  
Installation manual  
AR18-10-B002 | v1.1 | 2010.02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
18 en | Technical Data  
Power Supply  
AR18-10-B002 | v1.1 | 2010.02  
Installation manual  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Security Systems  
© Bosch Security Systems, 2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Computer Drive 8820 00417 F4U024 User Manual
Black Box Computer Monitor FT995A User Manual
Black Box Flat Panel Television LE003A UTP User Manual
Bosch Appliances Clothes Dryer WTMC1301CN User Manual
Braun Iron SI 6240 User Manual
Bravetti Blender BB301 User Manual
Brother Fax Machine FAX 335MCS User Manual
Campbell Hausfeld Fitness Electronics WS2100 User Manual
Casio Electronic Keyboard CTK 401 User Manual
Casio Watch DQD 500J User Manual