Black Box Switch KV120A User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSWITCH™ FAMILY  
Welcome to the ServSwitch™ Family!  
Thank you for purchasing a BLACK BOX® ServSelect IP! We appreciate your  
business, and we think you’ll appreciate the many ways that your new ServSelect IP  
will save you money, time, and effort.  
That’s because our ServSwitch family is all about breaking away from the traditional,  
expensive model of computer management. You know, the one-sizefits-all-even-if-it-  
doesn’t model that says, “One computer gets one user station, no more, no less.” Why  
not a single user station (monitor, keyboard, and mouse) for multiple computers—even  
computers of different platforms? Why not a pair of user stations, each of which can  
control multiple computers? Why not multiple user stations for the same computer?  
With our ServSwitch products, there’s no reason why not. We carry a broad line of  
robust solutions for all these applications. Do you have just two PCs, and need an  
economical alternative to keeping two monitors, keyboards, and mice on your desk?  
Or do you need to share dozens of computers, including a mix of IBM® PC,  
RS/6000®, Apple® Macintosh®, Sun Microsystems®, and SGI™ compatibles  
among multiple users with different access levels? Does your switch have to sit  
solidly on a worktable and use regular everyday cables? Or does it have to be  
mounted in an equipment rack and use convenient many-to-one cables? No matter  
how large or small your setup is, no matter how simple or how complex, we’re  
confident we have a ServSwitch system that’s just right for you.  
The ServSwitch™ family from BLACK BOX—the one-stop answer for all your  
KVM switching needs!  
*
This manual will tell you all about your new ServSelect IP, including how to install,  
operate, and troubleshoot it. For an introduction to the ServSelect IP, see Chapter 2.  
The ServSelect IP product codes covered in this manual are:  
KV120A KV120E KV121A KV212E  
This manual also includes information about the ServSelect IP Software and the  
Server Access Modules, which have their own manuals or installation guides:  
KV125A KV126A KV127A KV128A  
And this manual also includes information about the ServSwitch™ Multi Z8 switch:  
KV158A  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
FEDERAL COMMUNICATIONS COMMISSION AND  
INDUSTRY CANADA  
RADIO-FREQUENCY INTERFERENCE STATEMENTS  
This equipment generates, uses, and can radiate radio-frequency energy and if not  
installed and used properly, that is, in strict accordance with the manufacturer’s  
instructions, may cause interference to radio communication. It has been tested and  
found to comply with the limits for a Class A computing device in accordance with  
the specifications in Subpart B of Part 15 of FCC rules, which are designed to  
provide reasonable protection against such interference when the equipment is  
operated in a commercial environment. Operation of this equipment in a residential  
area is likely to cause interference, in which case the user at his own expense will be  
required to take whatever measures may be necessary to correct the interference.  
Changes or modifications not expressly approved by the party responsible for  
compliance could void the user’s authority to operate the equipment.  
This digital apparatus does not exceed the Class A limits for radio noise emission from  
digital apparatus set out in the Radio Interference Regulation of Industry Canada.  
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les  
limites applicables aux appareils numériques de la classe A prescrites dans le  
Règlement sur le brouillage radioélectrique publié par Industrie Canada.  
EUROPEAN UNION DECLARATION OF CONFORMITY  
This equipment has been tested and found to comply with the limits for a class A  
computing device in accordance with the specifications in the European standard  
EN55022. These limits are designed to provide reasonable protection against  
harmful interference. This equipment generates, uses and can radiate radio-  
frequency energy, and if not installed and used in accordance with the instructions,  
might cause harmful interference to radio or television reception.  
However, there is no guarantee that harmful interference will not occur in a  
particular installation. If this equipment does cause interference to radio or television  
reception, which can be determined by turning the equipment on and off, you can  
correct the interference with one or more of the following measures:  
(a) Reorient or relocate the receiving antenna.  
(b) Increase the separation between the equipment and the receiver.  
(c) Connect the equipment to an outlet on a circuit different from that to which the  
receiver is connected.  
(d) Consult the supplier or an experienced radio/TV technician for help.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPLIANCE STATEMENTS  
Shielded cables must be used with this equipment to maintain compliance with radio  
frequency energy emission regulations and ensure a suitably high level of immunity  
to electromagnetic disturbances. This equipment has also been found to comply with  
European standards EN50082 and EN60950.  
Japanese Compliance Statement  
Other Agency Approvals  
UL 1950, CSA C22. 2 No. 950, IEC 950  
Republic of Korea EMI Standard Certificate Number: E-F900-01-2012 (A)  
TRADEMARKS USED IN THIS MANUAL  
BLACK BOX and the  
logo are registered trademarks, and ServSwitch,  
ServSelect, and ServSelect IP are trademarks, of BLACK BOX Corporation.  
Apple, Mac, and Macintosh are registered trademarks of Apple Computer, Inc.  
IBM, PS/2, and RS/6000 are registered trademarks of International Business  
Machines Corporation.  
Microsoft, HyperTerminal, Windows, Windows NT, and Windows XP are  
trademarks or registered trademarks of Microsoft Corporation in the United States  
and/or other countries.  
Sun and Sun Microsystems are registered trademarks of Sun Microsystems, Inc. in  
the United States and other countries.  
UL is a registered trademark of Underwriters Laboratories Inc.  
Any other trademarks mentioned in this manual are acknowledged to be the property  
of the trademark owners.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
Normas Oficiales Mexicanas (NOM)  
Electrical Safety Statement  
INSTRUCCIONES DE SEGURIDAD  
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de  
que el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para  
referencia futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de  
operación deben ser respetadas.  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de  
la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que  
sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea  
recomendado por el fabricante.  
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a  
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser  
referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera  
su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o  
superficie similar puede bloquea la ventilación, no se debe colocar en libreros o  
gabinetes que impidan el flujo de aire por los orificios de ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como  
radiadores, registros de calor, estufas u otros aparatos (incluyendo  
amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo  
descrito en el instructivo de operación, o como se indique en el aparato.  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización  
del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean  
pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo  
particular atención a los contactos y receptáculos donde salen del aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las  
recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas  
de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea  
usado por un largo periodo de tiempo.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOM STATEMENT  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean  
derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su  
desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
Contents  
1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
2.1 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
2.2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12  
3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
3.1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
3.2 Rackmounting Your ServSelect IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
3.3 Installing the ServSelect IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15  
3.4 Setting Up Your ServSelect IP and Software . . . . . . . . . . . . . . . . . . . . . . . . . .19  
4. Analog Port Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
4.1 Controlling Your System at the Analog Port . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
4.2 Viewing and Selecting Ports and Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
4.3 Navigating the OSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
4.4 Configuring the OSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
4.5 Viewing and Disconnecting User Connections . . . . . . . . . . . . . . . . . . . . . . . . .31  
4.6 Resetting Your Keyboard and Mouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
4.7 Displaying Version Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
4.8 Scanning Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
4.9 Broadcasting to Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36  
5. Terminal Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38  
6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
6.1 Calling BLACK BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
6.2 Shipping and Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
Appendix: FLASH Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41  
A.1 Upgrading the ServSelect IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41  
A.2 Upgrading the SAM firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 1: PRODUCT OVERVIEW  
1. Specifications  
During the course of this product’s lifetime, modifications might be made to its  
hardware or firmware that could cause these specifications to change without notice.  
Agency Approvals  
EN55022 Class A, EN55024, EN61000-3-3, FCC15 Class A,  
VCCI Class A, IEC950, EN60950, UL 1950/60950 third  
edition, CSA C22.2 No. 950  
Server Ports  
Number  
16  
Interface Type  
Proprietary composite of video, keyboard and mouse (to  
SAM adapters)  
Connectors  
RJ-45  
Sync Types  
Plug and Play  
Video Resolution  
Separate horizontal and vertical  
DDC2B  
Analog Port Maximum 1600 x 1280 @ 75 Hz  
Digital Port Maximum 1280 x 1024 @ 75 Hz  
Configuration Port  
Number  
1
Interface Type  
Connector  
Serial RS-232, DTE  
DB9 Female  
Network Connection  
Number  
1
Interface Type  
Ethernet: IEEE 802.3, 10BASE-T,  
Fast Ethernet: IEEE 802.3U, 100BASE-T  
Connector  
Analog Port  
Number  
RJ-45  
1
Interface Types  
Connectors  
PS/2 and VGA  
(2) 6 pin MiniDIN, (1) HD15  
Other Characteristics  
Heat Dissipation  
Airflow  
92 BTU/Hr  
8 cfm  
Temperature  
10º to 50º Celsius (50º to 122º Fahrenheit) operating  
-20º to 60º Celsius (-4º to 140º Fahrenheit) nonoperating  
Humidity  
Power  
20 to 80% noncondensing operating  
5 to 95% noncondensing nonoperating  
100 to 240 VAC, 50 to 60 Hz (autosensing), 40 W maximum  
AC-input current rating 1A  
AC-input cable  
18 AWG three-wire cable, with a three lead IEC-320  
receptacle on the power supply end and a country or region  
dependent plug on the power resource end  
25 W  
Power Consumption  
Size (HxWxD)  
4.45 x 43.18 x 27.94 cm 1U form factor  
(1.75 x 17.00 x 11.00 in)  
Weight  
3.6 kg (8 lb) without cables  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVSELECT™ IP INSTALLER/USER GUIDE  
2. Introduction  
2.1 Features and Benefits  
The BLACK BOX® ServSelect™ IP switches combine analog and digital technology  
to provide flexible, centralized control of data center servers. This solution delivers  
secure digital access and flexible server management from anywhere at any time.  
NOTE:  
Throughout the text, the word “appliance” is used generically to describe the ServSelect IP switch.  
The ServSelect IP consists of a rackmountable keyboard, video and mouse (KVM)  
switch configurable for analog or digital connectivity. Each ServSelect IP has  
16 Analog Rack Interface (ARI) ports for connecting devices and operates over  
standard LAN connections. Access servers across a 100BASE-T Ethernet connection  
or directly through an analog port on the ServSelect IP for analog KVM connectivity  
and administration. Video resolutions through the analog port can be up to 1600 x  
1280 with an end-to-end cable length of up to 15 meters (50 feet). Digital users can  
achieve video resolution of up to 1280 x 1024 with a cable length of up to 10 meters  
(32 feet) between the ServSelect IP and the server.  
Number  
of  
Digital  
users  
Analog  
user  
servers*  
ServSelect IP - KV120  
ServSelect IP - KV121  
128  
1
1
128  
2
1
*Maximum number of servers with a fully configured KV158Aswitch attached to each of the 16ARI ports.  
Figure 2-1. ServSelect IP Model Comparison  
Server Access Modules  
The Server Access Module (SAM) with CAT5 design dramatically reduces cable  
clutter, while providing optimal digital display resolution and video settings. The  
built-in memory of the SAM simplifies configuration by assigning and retaining  
unique server names or Electronic ID (EID) numbers for each attached server. This  
integrated intelligence enhances security and prevents unauthorized access to a  
server through cable manipulation. The SAM is powered directly from the server  
and provides Keep Alive functionality even if the ServSelect IP is not powered.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 2: INTRODUCTION  
Access via network connection  
No special software or drivers are required on the attached computers. Digital users  
access the ServSelect IP and all attached systems via Ethernet from a PC running  
ServSelect IP Software. This software resides on the user’s PC only. User PCs can  
be located anywhere a valid network connection exists. The ServSelect IP can be  
configured on a separate network from your data network, allowing access to your  
servers even if your applications network is down.  
Point and click control with ServSelect IP Software  
The ServSelect IP Software is a cross-platform management application that allows you  
to view and control the ServSelect IP and all attached servers. The ServSelect IP  
Software provides secure authentication, data transfers and username/password storage.  
By utilizing a browser interface for navigation with an intuitive split-screen interface,  
this software provides you with a single point of access for your entire system. From  
here, you can manage the ServSelect IP, install a new ServSelect IP or launch a video  
session to a system server. Multiple servers can be accessed by one user; each additional  
computer’s video will appear in a separate program window.  
SAM  
Switch  
Adapter  
Rack of  
Servers  
SAM  
Switch  
Adapter  
Rack of  
Servers  
Critical Server  
ServSelect IP  
TCP/IP  
Analog Connection  
TCP/IP  
IP Connections  
Figure 2-2. Example ServSelect IP Configuration  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
2.2 Safety Precautions  
To avoid potential video and/or keyboard problems when using these products:  
If the building has 3-phase AC power, ensure that the computer and monitor are  
on the same phase. For best results, they should be on the same circuit.  
Use only BLACK BOX-supplied cable to connect computers and KVM switches.  
To avoid potentially fatal shock hazard and possible damage to equipment, please  
observe the following precautions:  
Do not use a 2-wire extension cord in any BLACK BOX product configuration.  
Test AC outlets at the computer and monitor for proper polarity and grounding.  
Use only with grounded outlets at both the computer and monitor. When using  
a backup power supply (UPS), power the computer, the monitor and the appli-  
ance off the supply.  
NOTE:  
The AC inlet is the main disconnect.  
Rackmount safety considerations  
Elevated Ambient Temperature: If the equipment is installed in a closed rack  
assembly, the operation temperature of the rack environment may be greater than  
room ambient. Use care not to exceed the rated maximum ambient temperature of  
the equipment.  
Reduced Air Flow: Installation of the equipment in a rack should be such that the  
amount of airflow required for safe operation of the equipment is not compromised.  
Mechanical Loading: Mounting of the equipment in the rack should be such  
that a hazardous condition is not achieved due to uneven mechanical loading.  
Circuit Overloading: Consideration should be given to the connection of the  
equipment to the supply circuit and the effect that overloading of circuits might  
have on overcurrent protection and supply wiring. Consider equipment name-  
plate ratings for maximum current.  
Reliable Earthing: Reliable earthing of rackmounted equipment should be  
maintained. Pay particular attention to supply connections other than direct  
connections to the branch circuit (for example, use of power strips).  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3: INSTALLATION  
3. Installation  
The ServSelect® IP system requires that the ServSelect IP Software be installed prior  
to use. ServSelect IP Software allows you to view and control a server attached to  
the appliance system, configure and maintain the system and prevent unauthorized  
access to the appliance via IP connection.  
NOTE:  
The analog port does not require the ServSelect IP Software for operation. The analog port uses  
the On-Screen Display (OSD). For more information, see Chapter 4.  
The ServSelect IP system uses Ethernet networking infrastructure and TCP/IP protocol  
to transmit keyboard, video and mouse information between operators and connected  
computers. Although 10BASE-T Ethernet may be used, a dedicated, switched  
100BASE-T network provides improved performance.  
3.1 Getting Started  
Before installing your ServSelect IP appliance, refer to the following list to ensure  
you have all items that shipped with the appliance as well as other items necessary  
for proper installation. The KV120/121A models ship with power input cords  
appropriate for North America. The KV120/121E models ship with power input  
cords appropriate for Europe.  
Supplied with the ServSelect IP  
ServSelect IP unit  
Power cord  
Rackmounting kit  
One straight-through null modem serial cable  
ServSelect IP Installer/User Guide  
ServSelect IP Software Installer/User Guide  
ServSelect IP Quick Installation Guide  
Additional items needed  
One SAM per attached server or switch  
Setting up your network  
The ServSelect IP system uses IP addresses to uniquely identify the appliances and  
the computers running ServSelect IP Software. The ServSelect IP appliance supports  
both BootP (a subset of DHCP) and static IP addressing. BLACK BOX®  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVSELECT™ IP INSTALLER/USER GUIDE  
recommends that IP addresses be reserved for each unit and that they remain static  
while the appliances are connected to the network.  
3.2 Rackmounting Your ServSelect IP  
Your ServSelect IP appliance ships with rackmounting brackets for easy integration  
into your rack. Before installing the appliance and other components in the rack  
cabinet, stabilize the rack in a permanent location. Install your equipment starting at  
the bottom of the rack cabinet, then work to the top. Avoid uneven loading or  
overloading of rack cabinets.  
To install the 1U switch mounting bracket:  
1. Line up the holes in the “long side” of the kit’s side brackets with the screw  
holes in the switch.  
2. With a Phillips screwdriver, fasten the mounting brackets to the switch using  
two 8/32" x 1/2" pan head screws on each side.  
3. Attach the four cage nuts or clip nuts to the rackmounting flange of the rack  
cabinet so that the nut is positioned on the inside of the rack.  
4. Mount the switch assembly to the rack cabinet by matching the holes in the “short  
side” of each bracket to an appropriate set of matching holes on your rack  
cabinet. Next, insert the combination hex head screws through the slots in the  
bracket and the holes in the mounting rail, then into the cage nuts or clip nuts.  
Figure 3-1. ServSelect IP Horizontal Installation  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3: INSTALLATION  
3.3 Installing the ServSelect IP  
Figure 3.2 illustrates one possible configuration for your ServSelect IP appliance.  
Follow the detailed set of procedures following Figure 3.2 to successfully install  
your appliance.  
Network  
Digital User  
one user for the KV120A or  
two users for the KV121A  
Configuration Port for  
updating firmware  
ServSelect IP Appliance  
ARI  
Port  
Power Cord  
Servers 2-16  
Local Analog  
User  
SAM Adaptor  
PS/2, USB and  
Sun adaptors are  
available  
Server 1  
Figure 3-2. Basic ServSelect IP Configuration  
CAUTION:  
To reduce the risk of electric shock or damage to your equipment-  
- Do not disable the power cord grounding plug. The grounding plug is an important safety feature.  
- Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times.  
- Disconnect the power from the unit by unplugging the power cord from either the electrical  
outlet or the unit.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVSELECT™ IP INSTALLER/USER GUIDE  
To install the ServSelect IP hardware:  
1. Connect a terminal or PC running terminal emulation software (such as  
HyperTerminal™) to the configuration port on the back panel of the appliance  
using an RS-232 DB9 null modem cable. The terminal should be set to  
9600 bps, 8 data bits, 1 stop bit, no parity and no flow control.  
2. Plug the supplied power cord into the back of the appliance and then into an  
appropriate power source.  
3. When you turn on the power, the Power indicator on the front of the unit will  
blink for 30 seconds while performing a self-test. Approximately 10 seconds after  
it stops blinking, press the Enter key to access the main menu.  
To configure the ServSelect IP hardware:  
1. You will see the Terminal Applications menu with six options. Select option 1,  
Network Configuration.  
Figure 3-3. Network Configuration Menu  
2. Select option 1 to set your network speed. When possible, you should set your  
connection manually without relying on the auto negotiate feature. Once you  
enter your selection, you will be returned to the Network Configuration menu.  
3. Select option 2 and specify if you are using a static or BootP IP address. Use a  
static IP address for ease of configuration. If you are using a BootP address,  
please configure your BootP server to provide an IP address to the appliance, skip  
step 4 and continue to the next procedure.  
4. Select options 3-5 from the Terminal Applications menu, in turn, to finish  
configuring your appliance for IP address, Netmask and Default Gateway. Once  
this is completed, type a Ø to return to the main menu.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 3: INSTALLATION  
To adjust the mouse acceleration:  
Before a server can be connected to the ServSelect IP, an adjustment to mouse  
acceleration must be made. Use the default Microsoft® Windows® PS/2® mouse  
driver for all attached Microsoft Windows systems attached to the appliance.  
For Microsoft Windows NT® (using default drivers):  
1. From the desktop, select Start - Settings - Control Panel - Mouse.  
2. Click on the Motion tab.  
3. Set the pointer speed to Slow. You will need to set this for any Windows NT user  
account that will be accessing the Windows NT system through the appliance.  
For Microsoft Windows 2000/Windows XP®:  
1. From the desktop, select Start - Settings - Control Panel - Mouse.  
2. Click on the Motion tab.  
3. Set the Acceleration setting to None and the speed setting to the default of 50%.  
To connect a SAM adapter to each server:  
1. Locate the SAM adaptors for your ServSelect IP unit.  
2. Attach the appropriately color-coded cable ends to the keyboard, monitor and  
mouse ports on the first server you will be connecting to the unit.  
3. Attach one end of the CAT5 cabling that will run between your SAM and  
ServSelect IP unit to the RJ-45 connector on the SAM adapter.  
4. Connect the other end of the CAT5 cable to the desired ARI port on the back of  
your ServSelect IP unit.  
5. Repeat steps 2-4 for all servers you wish to attach.  
NOTE:  
When connecting a Sun SAM adapter, you must use a multi-sync monitor to accommodate Sun  
computers that support both VGA and sync-on-green or composite sync.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
To add a KV158A ServSwitch® Multi Z8 switch:  
You can add a KV158A ServSwitch Multi Z8 to the ServSelect IP system. In a  
cascaded system, each ARI port will accommodate up to eight servers.  
ServSelect IP Appliance  
Server Access Modules  
(KV125 - KV128)  
PS/2, USB and Sun  
cables versions are  
available  
KV158A ServSwitch  
Local Analog  
User  
Server 1  
Figure 3-4. ServSelect IP Configuration with a Legacy KVM Switch  
1. Mount the Z8 into your rack cabinet. Locate a length of CAT5 cabling to  
connect your appliance to the SAM for your Z8.  
2. Attach one end of the CAT5 cabling to the RJ-45 connector on the SAM.  
3. Connect the other end of the CAT5 cable to a port on the back of your  
ServSelect IP.  
4. Attach the keyboard, monitor and mouse connectors of the SAM to a user port  
on your Z8.  
5. Connect the servers to your Z8 according to the instructions in the Z8’s manual.  
6. Power cycle the Z8 to enable the cascade code.  
7. Repeat steps 2-6 for all Z8s you want to attach to your system.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 3: INSTALLATION  
To connect the network and turn on your ServSelect IP:  
1. Connect your network cable from the LAN port on the rear of the ServSelect IP  
appliance to your network.  
2. The components in the ServSelect IP system may be turned on in any order.  
However, since the SAMs are powered by the servers, turn on the servers  
first and then turn on all attached systems for the most efficient startup.  
3.4 Setting Up Your ServSelect IP and Software  
See the ServSelect IP Software Installer/User Guide that ships with your appliance.  
The ServSelect IP system has a local analog port that allows you to attach a monitor  
and a PS/2 keyboard and mouse to the back of the unit. First, set up your servers at  
the analog port via the OSD before proceeding to use the ServSelect IP Software to  
finish configuring your system. Proceed to Chapter 4 in this installer/user guide for  
detailed instructions on the OSD setup and configuration. Once your servers are  
named, you will want to use a digital station to configure the ServSelect IP  
Software. See the ServSelect IP Quick Installation Guide for an overview of the  
hardware and software installation procedure.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVSELECT™ IP INSTALLER/USER GUIDE  
4. Analog Port Operation  
4.1 Controlling Your System at the Analog Port  
The ServSelect® IP includes a local analog port on the back of the unit that allows you to  
connect a monitor and a PS/2 keyboard and mouse for direct analog access. The  
appliance uses the OSD, which utilizes intuitive menus to configure your system and  
select computers.  
4.2 Viewing and Selecting Ports and Servers  
Use the OSD Main dialog box to view, configure and control servers in the  
ServSelect IP system. View your servers by name, port or by the unique Electronic  
ID number (EID) embedded in each SAM. You will see an OSD-generated port list  
by default when you first launch the OSD.  
The Port column indicates the ARI port to which a server is connected. If you  
connect a legacy KVM switch to the appliance, the port numbering displays the ARI  
port first, then the switch port to which the server is connected. For example, in  
Figure 4-1, servers 04-03 and 01-02 are connected to switches.  
To access the Main dialog box:  
Press Print Screen to launch the OSD. The Main dialog box appears.  
Figure 4-1. Example of Configured Main Dialog Box  
NOTE:  
You can also press the Control key twice within one second to launch the OSD. You can use this  
key sequence in any place you see Print Screen throughout this installer/user guide.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4: ANALOG PORT OPERATION  
Viewing the status of your appliance  
The status of the servers in your system is indicated in the right columns of the Main  
dialog box. The following table describes the status symbols.  
OSD Status Symbols  
Symbol Description  
SAM is online (green circle).  
SAM is offline or is not operating properly.  
Connected switch is online.  
Connected switch is offline or is not operating properly.  
SAM is being upgraded (yellow circle).  
SAM is being accessed by the indicated user channel.  
SAM is blocked by the indicated user channel. For instance, in Figure 4-1, user B  
is viewing Forester, but is blocking access to Acton, Barrett and Edie which are  
connected to the same SAM chain.  
Selecting servers  
Use the Main dialog box to select servers. When you select a server, the appliance  
reconfigures the keyboard and mouse to the proper settings for that server.  
To select servers:  
Double-click the server name, EID or port number.  
-or-  
If the display order of your server list is by port (Port button is depressed), type the  
port number and press Enter.  
-or-  
If the display order of your server list is by name or EID number (Name or EID  
button is depressed), type the first few characters of the name of the server or the  
EID number to establish it as unique and press Enter.  
To select the previous server:  
Press Print Screen and then Backspace. This key combination toggles you between  
the previous and current connections.  
To disengage the user from a server:  
Press Print Screen and then Alt+Ø. This leaves the user in a free state, with no server  
selected. The status flag on your desktop displays Free.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
Soft switching  
Soft switching is the ability to switch servers using a hotkey sequence. You can soft  
switch to a server by pressing Print Screen and then typing the first few characters  
of its name or number. If you have set a Screen Delay Time and you press the key  
sequences before that time has elapsed, the OSD will not display.  
To configure servers for soft switching:  
1. Press Print Screen to launch the OSD. The Main dialog box appears.  
2. Click Setup - Menu. The Menu dialog box appears.  
3. For Screen Delay Time, type the number of seconds of delay desired before the  
Main dialog box is displayed after Print Screen is pressed.  
4. Click OK.  
To soft switch to a server:  
1. To select a server, press Print Screen. If the display order of your server list is by  
port (Port button is depressed), type the port number and press Enter.  
-or-  
If the display order of your server list is by name or EID number (Name or EID  
button is depressed), type the first few characters of the name of the server or  
the EID number to establish it as unique and press Enter.  
2. To switch back to the previous server, press Print Screen then Backspace.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: ANALOG PORT OPERATION  
4.3 Navigating the OSD  
This table describes how to navigate the OSD using the keyboard and mouse.  
OSD Navigation Basics  
This Keystroke  
Print Screen  
Does This  
Opens the OSD. Press Print Screen twice to send the Print  
Screen keystroke to the currently selected device.  
F1  
Opens the Help screen for the current dialog box.  
Escape  
Closes the current dialog box without saving changes and returns  
to the previous one. In the Main dialog box, it closes the OSD and  
returns to the flag. In a message box, it closes the pop-up box and  
returns to the current dialog box.  
Alt  
Opens dialog boxes, selects or checks options and executes  
actions when used with underlined or other designated letters.  
Alt+X  
Closes the current dialog box and returns to the previous one.  
Alt+O  
Selects the OK button, then returns to the previous dialog box.  
Single-click, Enter  
In a text box, it selects the text for editing and enables the Left  
and Right Arrow keys to move the cursor. Press Enter again to  
quit the edit mode.  
Enter  
Completes a switch in the Main dialog box and exits the OSD.  
Print Screen, Backspace Toggles back to previous selection.  
Print Screen, Alt+Ø  
Immediately disengages user from a server; no server is  
selected. Status flag displays Free. (This only applies to the Ø on  
the keyboard and not the keypad.)  
Print Screen, Pause  
Immediately turns on screen saver mode and prevents access to  
that particular console, if it is password protected.  
Up/Down Arrows  
Right/Left Arrows  
Moves the cursor from line to line in lists.  
Moves the cursor between columns. When editing a text box,  
these keys move the cursor within the column.  
Page Up/Page Down  
Home/End  
Pages up and down through Name and Port lists and Help pages.  
Moves the cursor to the top or bottom of a list.  
Erases characters in a text box.  
Backspace  
Delete  
Deletes current selection in the scan list or characters in a text  
box.  
Shift-Del  
Deletes from the current selection to the end of the list when  
editing a scan list.  
Numbers  
Type from the keyboard or keypad.  
Caps Lock  
Disabled. Use the Shift key to change case.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVSELECT™ IP INSTALLER/USER GUIDE  
4.4 Configuring the OSD  
You can configure your ServSelect IP system from the Setup menu within the OSD.  
Select the Names button when initially setting up your appliance to identify servers  
by unique names. Select the other setup features to manage routine tasks for your  
servers from the the OSD menu.  
Setup Features to Manage Routine Tasks for your Servers  
Feature  
Menu  
Purpose  
Change the server listing between numerically by port or EID number and  
alphabetically by name.  
Change the Screen Delay Time before the OSD displays after pressing Print  
Screen.  
Flag  
Change display, timing, color or location of the status flag.  
Broadcast  
Set up to simultaneously control multiple servers through keyboard and  
mouse actions.  
Scan  
Set up a custom scan pattern for up to 16 servers.  
Set passwords to restrict server access.  
Enable the screen saver.  
Security  
Devices  
Names  
Identify the number of ports on an attached cascade switch.  
Identify servers by unique names.  
To access the Setup menu:  
1. Press Print Screen to launch the OSD. The Main dialog box appears.  
2. Click Setup. The Setup dialog box appears.  
Figure 4-2. Setup Dialog Box  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4: ANALOG PORT OPERATION  
Assigning server names  
Use the Names dialog box to identify individual servers by name rather than by port  
number. The Names list is always sorted by port order. Names are stored in the  
SAM, so even if you move the cable/server to another ARI port, the name and  
configuration will be recognized by the appliance.  
NOTE:  
If a server is turned off, its respective SAM will not appear in the Names list.  
To access the Names dialog box:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Setup - Names. The Names dialog box appears.  
Figure 4-3. Names Dialog Box  
NOTE:  
If the server list changes, the mouse cursor will turn into an hourglass as the list is automatically  
updated. No mouse or keyboard input will be accepted until the list update is complete.  
To assign names to servers:  
1. In the Names dialog box, select a server name or port number and click Modify.  
The Name Modify dialog box appears.  
Figure 4-4. Name Modify Dialog Box  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
2. Type a name in the New Name box. Names of servers may be up to 15 characters  
long. Legal characters include: A-Z, a-z, Ø-9, space and hyphen.  
3. Click OK to transfer the new name to the Names dialog box. Your selection is  
not saved until you click OK in the Names dialog box.  
4. Repeat steps 1-3 for each server in the system.  
5. Click OK in the Names dialog box to save your changes.  
-or-  
Click X or press Escape to exit the dialog box without saving changes.  
NOTE:  
If a SAM has not been assigned a name, the EID is used as the default name.  
Assigning device types  
The appliance automatically discovers ServSwitch Multi Z8s that are attached to it  
and will automatically assign the number of ports (eight) to that switch. You will see  
an Sw-8 appear in the Type category. When you select that switch from the list, the  
Modify button appears, but do not click it: at the time of this writing, the KV158A  
2x8 ServSwitch Multi Z8 is the only available cascade switch; do not attempt to  
select or add other switch types, or specify a different number of ports.  
To access the Devices dialog box:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Setup - Devices. The Devices dialog box appears.  
Figure 4-5. Devices Dialog Box  
When the ServSelect IP appliance discovers a ServSwitch Multi Z8, you will notice  
the port numbering change to accommodate each server under that switch. For  
example, if the switch is connected to ARI port 6, the switch port would be listed as  
06 and each server under it would be numbered sequentially 06-01, 06-02 and so on.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: ANALOG PORT OPERATION  
Changing the display behavior  
Use the Menu dialog box to change the display order of servers and set a Screen  
Delay Time for the OSD. The display order setting alters how servers will display in  
several screens including the Main, Devices and Broadcast dialog boxes.  
To access the Menu dialog box:  
1. Press Print Screen to launch the OSD. The Main dialog box appears.  
2. Click Setup - Menu in the Main dialog box. The Menu dialog box appears.  
Figure 4-6. Menu Dialog Box  
To choose the default display order of servers:  
1. Select Name to display servers alphabetically by name.  
-or-  
Select EID to display servers numerically by EID number.  
-or-  
Select Port to display servers numerically by port number.  
2. Click OK.  
To set a Screen Delay Time for the OSD:  
1. Type in the number of seconds (Ø-9) to delay the OSD display after you press Print  
Screen. Entering Ø will instantly launch the OSD with no delay.  
2. Click OK.  
Setting a Screen Delay Time allows you to complete a soft switch without the OSD  
displaying. To perform a soft switch, see Soft switching in this chapter.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
Controlling the status flag  
The status flag displays on your desktop and shows the name or EID number of the  
selected server or the status of the selected port. Use the Flag dialog box to configure  
the flag to display by server name or EID number, or to change the flag color,  
opacity, display time and location on the desktop.  
OSD Status Flags  
Flag  
Description  
Flag type by name  
Flag type by EID number  
Flag indicating that the user has been disconnected from all systems  
Flag indicating that Broadcast mode is enabled  
To access the Flag dialog box:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Setup - Flag. The Flag dialog box appears.  
Figure 4-7. Flag Dialog Box  
To determine how the status flag is displayed:  
1. Select Name or EID to determine what information will be displayed.  
2. Select Displayed to show the flag all the time or select Timed to display the flag  
for only five seconds after switching.  
3. Select a flag color in Display Color.  
4. In Display mode, select Opaque for a solid color flag or select Transparent to  
see the desktop through the flag.  
5. To position the status flag on the desktop:  
a. Click Set Position to gain access to the Position Flag screen.  
b. Left-click on the title bar and drag to the desired location.  
c. Right-click to return to the Flag dialog box.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: ANALOG PORT OPERATION  
Figure 4-8. Position Flag  
NOTE:  
Changes made to the flag position are not saved until you click OK in the Flag dialog box.  
6. Click OK to save settings.  
-or-  
Click X to exit without saving changes.  
Setting console security  
The OSD enables you to set security on your analog port console. You can establish a  
screen saver mode that engages after your console remains unused for a specified Inactivity  
Time. Once engaged, your console will remain locked until you press any key or move the  
mouse. You will then need to type in your password to continue.  
Use the Security dialog box to lock your console with password protection, set or  
change your password and enable the screen saver.  
NOTE:  
If a password has been previously set, you will have to enter the password before you can access  
the Security dialog box.  
To access the Security dialog box:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Setup - Security. The Security dialog box appears.  
Figure 4-9. Security Dialog Box  
To set or change the password:  
1. Single-click and press Enter or double-click in the New text box.  
2. Type the new password in the New text box and press Enter. Passwords must  
contain both alpha and numeric characters, are case sensitive and may be up to 12  
characters long. Legal characters are: A-Z, a-z, Ø-9, space and hyphen.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
3. In the Repeat box, type the password again and press Enter.  
4. Click OK to change only your password, and then close the dialog box.  
NOTE:  
If you should lose or forget your password, you must return your ServSelect IP.  
To password protect your console:  
1. Set your password as described in the previous procedure.  
2. Select Enable Screen Saver.  
3. Type the number of minutes for Inactivity Time (from 1 to 99) to delay  
activation of password protection and the screen saver feature.  
4. For Mode, select Energy if your monitor is ENERGY STAR® compliant; otherwise  
select Screen.  
CAUTION:  
Monitor damage can result from using Energy mode with monitors not compliant with ENERGY STAR.  
5. (Optional) Click Test to activate the screen saver test which lasts 10 seconds  
then returns you to the Security dialog box.  
6. Click OK.  
To log in to your console:  
1. Press any key or move the mouse.  
2. The Password dialog box appears. Type your password, then click OK.  
3. The Main dialog box appears if the password was entered properly.  
To remove password protection from your console:  
1. From the Main dialog box, click Setup - Security; the Password dialog box  
appears. Type your password, then click OK.  
2. In the Security dialog box, single-click and press Enter or double-click in the  
New box. Leave the box blank. Press Enter.  
3. Single-click and press Enter or double-click in the Repeat box. Leave the box  
blank. Press Enter.  
4. Click OK to eliminate your password.  
To enable the screen saver mode with no password protection:  
1. If your console does not require a password to gain access to the Security dialog  
box, proceed to step 2.  
-or-  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: ANALOG PORT OPERATION  
If your console is password protected, see the previous procedure, then go to step 2.  
2. Select Enable Screen Saver.  
3. Type the number of minutes for Inactivity Time (from 1–99) to delay activation  
of the screen saver.  
4. Choose Energy if your monitor is ENERGY STAR compliant; otherwise select Screen.  
CAUTION:  
Monitor damage can result from using Energy mode with monitors not compliant with ENERGY STAR.  
5. (Optional) Click Test to activate the screen saver test which lasts 10 seconds  
then returns you to the Security dialog box.  
6. Click OK.  
NOTE:  
Activation of the screen saver mode disconnects the user from a server; no server is selected. The  
status flag displays Free.  
To exit the screen saver mode:  
Press any key or move your mouse. The Main dialog box appears and any previous  
server connection will be restored. If a digital user is on that connection, they will be  
disconnected and will receive a preemption message.  
To turn off the screen saver:  
1. In the Security dialog box, clear Enable Screen Saver.  
2. Click OK.  
To immediately turn on the screen saver:  
Press Print Screen, then press Pause.  
4.5 Viewing and Disconnecting User Connections  
You can view and disconnect users through the User Status dialog box. The user  
name (U) will always be displayed; however, you can display either the server name  
or EID number to which a user is connected. If there is no user currently connected  
to a channel, the user field will be blank and the server field will display Free.  
To view current user connections:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Commands - User Status. The User Status dialog box appears.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVSELECT™ IP INSTALLER/USER GUIDE  
To disconnect a user:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Commands - User Status. The User Status dialog box appears.  
3. Click the letter of a user to disconnect. The Disconnect dialog box will appear.  
Figure 4-10. User Status Dialog Box Figure 4-11. Disconnect Dialog Box  
4. Click OK to disconnect the user and return to the User Status dialog box.  
-or-  
Click X or press Escape to exit the dialog box without disconnecting a user.  
NOTE:  
If the User Status list has changed since it was last displayed, the mouse cursor will turn into an  
hourglass as the list is automatically updated. No mouse or keyboard input will be accepted until  
the list update is complete.  
4.6 Resetting Your Keyboard and Mouse  
If your keyboard or mouse locks up during a communication with a CPU that has PS/2  
type keyboard and mouse ports, you may be able to re-establish operation by issuing a  
reset command. The reset command sends a key sequence to the server which causes the  
mouse and keyboard settings to be sent to the appliance. With communication re-  
established between the server and the appliance, functionality is restored to the user.  
To reset the mouse and keyboard values:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Commands - Reset PS/2. A message box displays indicating that the  
mouse and keyboard have been reset.  
3. Click X to close the message box.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4: ANALOG PORT OPERATION  
4.7 Displaying Version Information  
The OSD enables you to display the ServSelect IP and SAM firmware versions. For  
optimum performance, keep your firmware current. For more information, see Appendix A.  
To display version information:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Commands - Display Versions. The Version dialog box appears. The top  
half of the box lists the subsystem versions in the appliance.  
Figure 4-12. Version Dialog Box  
3. Click Digital to view the Digitizer unit firmware versions. The Digital Version  
dialog box appears. The top section identifies the Digitizer subsystem versions.  
The center section identifies the current network settings. Click X or press  
Escape to return to the Version dialog box.  
Figure 4-13. Digital Version Dialog Box  
4. Click SAM (see Figure 4-12) to view individual SAM version information. The  
SAM Selection dialog box appears.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
Figure 4-14. SAM Selection Dialog Box  
5. Select a SAM to view and click the Version button. The SAM Version dialog  
box appears. For more information on loading firmware, see Appendix A.  
Figure 4-15. SAM Version Dialog Box  
6. Click X to close the Version dialog box.  
4.8 Scanning Your System  
In scan mode, the appliance automatically scans from port to port (server to server).  
You can scan up to 16 servers, specifying which servers to scan and the number of  
seconds that each server will display. The scanning order is determined by placement  
of the server in the list. The list is always shown in scanning order. You can, however,  
choose to display the server’s name or EID number by pressing the appropriate button.  
NOTE:  
Scanning is only available to the local analog user.  
To add servers to the scan list:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Setup - Scan. The Scan dialog box appears.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4: ANALOG PORT OPERATION  
Figure 4-16. Scan Dialog Box  
3. Determine the order within the list to add the server. If there are no servers in the  
scan list, your cursor will appear in a blank line at the top of the list.  
-or-  
To add a server to the end of the list, place your cursor in the last server entry  
and press the Down Arrow key.  
-or-  
To add a server in the midst of an existing list, place your cursor at the entry  
below where you want to insert a new server and press Insert.  
4. Type the first few characters of a server name or port number to scan. The first  
matching server will appear in the line.  
-or-  
To move through the list, press the following keyboard commands in the Name, Port  
or Sec column to move through the list of servers available to scan.  
a. Press Alt+Down Arrow to move the cursor down through the list of servers.  
b. Press Alt+Up Arrow to move the cursor up through the list of servers.  
c. Press Alt+Home to move the cursor to the first server in the list.  
d. Press Alt+End to move the cursor to the last server in the list.  
5. In the Sec column, type the number of seconds (from 3 to 255) of desired time  
before the scan moves to the next server in the sequence.  
6. Move the cursor to the next line or press the Down Arrow and repeat steps 2-5 for  
each of the remaining servers to be included in the scan pattern.  
7. Click OK.  
To remove a server from the scan list:  
1. In the Scan dialog box, click the server to be removed.  
2. Press Delete.  
-or-  
Press Shift+Delete to remove the selected server and all entries below it.  
3. Click OK.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
To start the scan mode:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Commands. The Command dialog box appears.  
Figure 4-17. Command Dialog Box  
3. Select Scan Enable in the Command dialog box.  
4. Click X to close the Command dialog box.  
NOTE:  
Scanning will commence when the Main dialog box or flag is displayed. Scanning is inhibited in  
any other the OSD dialog box.  
To cancel scan mode:  
1. Select a server if the OSD is open.  
-or-  
Move the mouse or press any key on the keyboard if the OSD is not open.  
Scanning will stop at the currently selected server.  
-or-  
Press Print Screen. The Main dialog box will appear.  
2. Click Commands. The Command dialog box appears.  
3. Clear Scan Enable.  
4.9 Broadcasting to Servers  
The analog user can simultaneously control more than one server in a system, to  
ensure that all selected servers receive identical input. You can choose to broadcast  
keystrokes and/or mouse movements independently.  
NOTE:  
You can broadcast to up to 16 servers at a time, one server per ARI port.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4: ANALOG PORT OPERATION  
To access the Broadcast dialog box:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Setup - Broadcast. The Broadcast dialog box appears.  
Figure 4-18. Broadcast Dialog Box  
NOTES:  
Broadcasting Keystrokes - The keyboard state must be identical for all servers receiving a  
broadcast to interpret keystrokes identically. Specifically, the keyboard Caps Lock and Num Lock  
modes must be the same for all servers. While the appliance attempts to send keystrokes to the  
selected servers simultaneously, some servers may inhibit and thereby delay the transmission.  
Broadcasting Mouse Movements - For the mouse to work accurately, all systems must have  
identical mouse drivers, desktops (such as identically placed icons) and video resolutions. In  
addition, the mouse must be in exactly the same place on all screens. Because these conditions  
are extremely difficult to achieve, broadcasting mouse movements to multiple systems may  
have unpredictable results.  
To broadcast to selected servers:  
1. From the Broadcast dialog box, select the mouse and/or keyboard checkboxes  
for the servers that are to receive the broadcast commands.  
-or-  
Press the Up or Down Arrow keys to move the cursor to the target server. Then  
press Alt+K to select the keyboard checkbox and/or Alt+M to select the mouse  
checkbox. Repeat for additional servers.  
2. Click OK to save the settings and return to the Setup dialog box. Click X or  
press Escape to return to the Main dialog box.  
3. Click Commands. The Command dialog box appears.  
4. Click the Broadcast Enable checkbox to activate broadcasting.  
5. From the user station, type the information and/or perform the mouse  
movements you want to broadcast.  
To turn broadcasting off:  
From the Command dialog box, clear the Broadcast Enable checkbox.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
5. Terminal Operations  
Each individual ServSelect® IP may be configured at the unit level through the  
configuration port on the back of the unit. All terminal commands are accessed  
through a terminal or PC running terminal emulation software.  
Configuring the Terminal Menu  
The ServSelect IP Terminal Applications menu features five selections: Network  
Configuration, Firmware Management, Enable Debug Messages, Set/Change  
Password and Exit.  
Figure 5-1. Network Configuration Menu  
To access the Terminal menu:  
1. Connect a terminal or PC running terminal emulation software (such as  
HyperTerminal) to the configuration port on the back panel of the ServSelect IP  
using a RS-232 DB9 null modem cable. The terminal should be set to 9600 bps,  
8 data bits, 1 stop bit, no parity and no flow control. The terminal may be  
connected at any time, even when the ServSelect IP is powered on.  
2. Press any key to access the main menu.  
Network Configuration  
The ServSelect IP is configured for network access through the Network  
Configuration option. When it is selected, you will have access to the addressing  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 5: TERMINAL OPERATIONS  
that allows the ServSelect IP to be positioned in your network. For more  
information, see Installing the ServSelect IP in Chapter 3.  
Firmware Management  
This menu option contains the FLASH Download command. The FLASH Download  
selection allows you to keep your ServSelect IP firmware current with upgrades  
available from BLACK BOX®. For more information, see Appendix A: FLASH  
Upgrades.  
Enable Debug Messages  
This menu option allows you to configure the ServSelect IP to display messages  
regarding the status of the ServSelect IP. Once you select the level of detail to receive,  
the ServSelect IP will begin to display information on your terminal screen. When you  
are finished viewing, press any key to exit this mode.  
Set/Change Password  
The ServSelect IP can be set to a secure mode where the Terminal menu cannot be  
accessed without first entering a password.  
To activate security:  
1. Select the Set/Change Password menu option. You will be prompted with the  
option to continue. Enter a Y.  
2. Type a password for this ServSelect IP and press Enter. This password must be a  
minimum of five characters and can be up to a maximum of 12 characters (10 are  
visible). The password must consist of a combination of letters and numbers.  
3. You will be prompted to re-type the password. Once you complete this step,  
security will be active and you will not be able to access ServSelect IP terminal  
operations without the password.  
To change the password:  
1. Select the Set/Change Password menu option.  
2. You will be prompted to type the old password and a new one.  
3. Re-type the new password to verify.  
NOTE:  
This password places your ServSelect IP terminal in a secure mode. This password should be  
guarded like any network password and care should be taken to avoid forgetting or misplacing it.  
There are no means for recovering a lost password.  
Exit  
This menu selection will return you to the ready prompt.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
6. Troubleshooting  
6.1 Calling BLACK BOX  
If you determine that your ServSelect IP is malfunctioning, do not attempt to alter or  
repair the unit. It contains no user-serviceable parts. Contact BLACK BOX  
Technical Support at 724-746-5500.  
Before you do, make a record of the history of the problem. We will be able to  
provide more efficient and accurate assistance if you have a complete  
description, including:  
the nature and duration of the problem;  
when the problem occurs;  
the components involved in the problem;  
any particular application that, when used, appears to create the problem or  
make it worse; and  
the results of any testing you’ve already done.  
6.2 Shipping and Packaging  
If you need to transport or ship your ServSelect IP:  
Package it carefully. We recommend that you use the original container.  
If you are shipping the ServSelect for repair, make sure you include its power  
cord and the cables you’re using with it. If you are returning the ServSelect  
IP, make sure you include everything you received with it. Before you ship,  
contact BLACK BOX to get a Return Authorization (RA) number.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
APPENDIX: FLASH UPGRADES  
Appendix: FLASH Upgrades  
A.1 Upgrading the ServSelect IP  
The ServSelect® IP FLASH upgrade feature allows you to upgrade your unit with the  
latest firmware available. To perform this update you will need a TFTP server. There are  
several free TFTP servers that you can download off the internet.  
Next, you will need to download the latest FLASH firmware from BLACK BOX®.  
Contact BLACK BOX technical support and follow their directions for downloading the  
firmware. Save the FLASH upgrade file to the appropriate directory on your TFTP server.  
Once this is complete, the following steps will upload the new FLASH file to the  
ServSelect IP.  
To upload a new FLASH file:  
1. Connect a terminal or PC running terminal emulation software (such as  
HyperTerminal) to the configuration port on the back panel of the ServSelect IP.  
The terminal should be set to 9600 bps, 8 data bits, 1 stop bit, no parity and no  
flow control.  
2. Connect the LAN port on the ServSelect IP to an Ethernet hub that is also  
connected to the PC being used as the TFTP server.  
3. Launch both the server software and the terminal emulation software.  
4. Verify that the ServSelect IP is turned on. After approximately 40 seconds, the  
ServSelect IP will send out a message, BLACK BOX ServSelect IP Ready__  
Press any key to continue. Press any key to access the main menu. The  
ServSelect IP main menu appears.  
5. Get the IP address of the TFTP server: If using the SolarWinds TFTP server, it  
appears in the lower right-hand corner of the server’s pane. Otherwise, extract  
it from the OS tools (may be OS-dependent):  
a. Right-click on Network Neighborhood.  
b. Select Properties.  
c. Select the Protocols tab.  
d. Select TCP/IP protocol.  
e. Select Properties and note the IP address.  
6. Assign the IP address in the ServSelect IP, if needed:  
a. In the HyperTerminal window, type 1 to select Network Configuration.  
b. Note the appliance IP address. The first three numbers must be the same as  
in the server’s IP address from step 5 above. The last number must be dif-  
ferent. If the IP address is not correct, change it as follows: type 3 to select  
IP address, then enter the correct address.  
c. Type Ø to exit the Network Configuration menu. If you changed the IP  
address, wait per the directions on the screen.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERVSELECT™ IP INSTALLER/USER GUIDE  
7. From the main menu, type 2 to select Firmware Management. The current  
version of your firmware displays in the Firmware Management screen.  
8. From the Firmware Management menu, type 1 to select FLASH Download.  
9. Type the IP address of the TFTP server and press Enter.  
10. Type the name of the FLASH file and press Enter.  
11. Confirm the TFTP download by typing y or yes and pressing Enter.  
12. The ServSelect IP will verify the file you downloaded is valid. Next you will be  
prompted to confirm the upgrade. Type y or yes and press Enter.  
13. The ServSelect IP will begin the FLASH upgrade process. On-screen indicators will  
display the upgrade process. When the upload is complete, the ServSelect IP will reset  
and upgrade the internal subsystems.  
CAUTION:  
Do not cycle power to the ServSelect IP during this process. A loss of power might render the  
appliance inoperable and require the unit be returned to the factory for repair. This upgrade may  
take up to 10 minutes to complete.  
14. Once the upgrade is complete, the startup message from step 4 will appear on  
the terminal screen.  
A.2 Upgrading the SAM firmware  
You may upgrade SAMs either individually or simultaneously.  
To simultaneously upgrade multiple SAMs:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Commands - SAM Status. The SAM Status dialog box appears.  
Figure A-1. SAM Status Dialog Box  
3. Click one or more types of adaptors to upgrade. Click Upgrade.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
APPENDIX: FLASH UPGRADES  
Figure A-2. SAM Upgrade Dialog Box  
4. The SAM Upgrade dialog box appears. Click OK to initiate the upgrade and  
return to the SAM Status dialog box.  
To upgrade SAM firmware individually:  
1. Press Print Screen. The Main dialog box will appear.  
2. Click Commands - Display Versions. The Version dialog box appears.  
Figure A-3. Version Dialog Box  
3. Click SAM to view individual cable version information.  
Figure A-4. SAM Selection Dialog Box  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVSELECT™ IP INSTALLER/USER GUIDE  
4. Select a SAM to upgrade and click the Version button. The SAM Version dialog  
box appears.  
Figure A-5. SAM Version Dialog Box  
5. Click the Load Firmware button. The Load dialog box appears.  
Figure A-6. SAM Load Dialog Box  
6. Click OK to initiate the upgrade and return to the Status dialog box.  
NOTE:  
During an upgrade, the SAM status indicator in the Main dialog box will be yellow. The SAM is  
unavailable while an upgrade is in progress. When an upgrade is initiated, any current connection  
to the server via the SAM will be terminated.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bissell Vacuum Cleaner 60P4 User Manual
Black Box Switch KV2116E User Manual
Black Decker Saw CD601 User Manual
BMW Automobile 1985 bmw 635csi User Manual
Braun Electric Shaver 360s 4 User Manual
Breville Kitchen Grill 800GR User Manual
Brother All in One Printer FAX 1170 User Manual
Canon Fax Machine 1060P User Manual
Capital Cooking Cooktop PSCT36 User Manual
Casablanca Fan Company Fan 53187 User Manual