| INTRODUCTION   Plug-In Power Devices   Thank you for purchasing a SurgeMaster Battery Backup   by Belkin. Each year, several natural and man-made   occurrences put the power supplied to your electronics in   your home or office in jeopardy. At risk are your hardware,   software, and data because of these power problems.   Plug your devices into the AC outlets on the top of   the UPS. To use the UPS as a master on/off switch,   make sure all of the loads are switched on.   Caution: Never connect a laser printer or scanner   to the backup outlets of the UPS with other   computer equipment. A laser printer or scanner   draws significantly more power when in use   than when idle. This may overload the UPS.   This product is designed to provide clean power to all   computer systems and peripherals with maximum protection.   It integrates quality surge protection and battery backup   capabilities to provide complete power protection for your   computer, modem, hard drive, and other related equipment.   This product will safeguard against power disturbances of all   kinds; blackouts, surges, spikes and line noise contamination.   Turning on the UPS   The UPS will perform a self-test each time the   UPS is switched on that determines whether the   battery can support the connected loads.   USERS MANUAL   Note! The UPS maintains the battery charge when   in the off position and will respond to commands   received through the computer interface port.   BELKIN SUPERIOR SERIES UPS   F6H350ukUNV   IMPORTANT SAFETY INSTRUCTIONS   Please save this manual!   It contains important operating instructions and   warranty information pertaining to your UPS.   F6H500ukUNV   F6H650ukUNV   To Conduct a Self-Test   Use the self-test to verify both the operation of the   UPS and the condition of the battery. In normal utility   power, recycle the power switch On/Off. During the   self-test, the UPS operates in backup mode.   NOTE:   P74778uk   During the installation of this equipment, it should be   assured that the sum of the leakage currents of the UPS   and the connected loads does not exceed 3.5mA.   ALARMS (cont.)   OVERLOAD (Continuous Alarm)   When the UPS is overloaded (the connected loads exceed the   maximum rated capacity), the UPS emits a continuous alarm   to warn of an overload condition. Disconnect nonessential   equipment from the UPS to eliminate the overload.   Note! During the self-test, the UPS briefly operates   on-battery backup power (the green Power LED   comes on and the unit emits a beep every 10 seconds).   If the UPS passes the self-test, it returns to online   operation. If the UPS fails the self-test, it immediately   returns to online operation. See details regarding the   Check Battery Indicator below in the next section.   Please save or recycle the packaging materials!   The UPS packaging was designed with great care   to provide protection during shipment and delivery.   These materials are invaluable if you ever have   to return the UPS for service. Damage sustained   during transit is not covered under the warranty.   REAR PANEL   Check Battery Indicator   This indicator is lighted when the unit has detected   a weak or worn-out battery during the self-   test. Please follow the procedure below to bring   the battery up to normal operating levels:   CONTENTS   You should have received the following:   1 – Battery Backup Product   1 – Shutdown Software CD w/Software Manual   1 – Users Manual (Multilanguage) CD   1 – USB Cable   1. Allow unit to charge for at least 12 hours   2. Re-test the battery by recycling the power switch   off/on. The unit will run a 2-second self-test again   to determine the strength of the battery.   1 – Serial Cable   3. If the Check Battery Indicated is lighted again,   contact Belkin to replace the battery.   1 – Phone Line Cable   To Silence Audible Alarm   UPS FEATURES AND FUNCTIONS   While in battery backup mode, push On/Off/Test   button less than 2 seconds to silence the audible   alarm. (This does not work if the UPS is under   LOW BATTERY or OVERLOAD condition.)   INTERNET/PHONE/FAX/DSL/NETWORK PROTECTION   The Internet/phone/fax/DSL/network lines are surge-   protected and provide complete safety for line connection.   Before installation, please inspect the UPS upon   receipt. Make sure that nothing is damaged.   Your UPS features 4 LED indicators that specify certain   functions on your UPS. Please review this chart and   it will assist you in the use of your battery backup.   ON/OFF Master Switch   (“I” means ON; “O” means OFF)   All equipment must be turned off prior   to hardware installation.   Indicator   Condition   Meaning   INTERFACE PORTS   The UPS provides both a USB and RS232   port for you use with your computer.   Solid Green   AC Power is on   PHONE/FAX/MODEM PROTECTION   POWER ON   (Green LED)   Connect a single Internet, phone or fax line into the surge-   protected ports on the back of the UPS. This comes with a   built-in line splitter to provide you with 2 output lines. The   RJ11 modular sockets accept standard, single-line telephone   connections. The connection will require another length of   telephone cable, which is included FREE with your purchase.   Flashing Green   every 10 seconds   Battery Backup is on   NOTE: Choose one port only.   Indicator will test itself   when unti turns on.   BATTERY BACKUP OUTLETS   Only data-sensitive equipment such as a computer, monitor,   and external drive should be plugged into these outlets.   Battery power is automatically provided in case of a power   outage. Power (AC or battery) is not supplied to these   outlets when the UPS is switched off. (Do not plug surge   protectors or power strips into the battery backup outlets).   1. In a low-battery scenario,   the check battery LED   will stay lighted until   the battery is charged   to acceptable level.   Phone-Line Connection with Built-In Splitter:   CHECK   BATTERY   (Yellow LED)   Solid Yellow LED   with Audible   Alarm (Beeping)   2. If while under battery   backup mode the battery   becomes too low, the   Power On LED will start   flashing every 1 second,   and the audible alarm will   sound every 1 second.   SURGE-ONLY PROTECTED OUTLETS   Equipment such as a printer, fax machine, scanner, or   a desk lamp can be plugged into these outlets. These   outlets do not provide power during a power outage.   These outlets are always on (when AC power is available)   and are not controlled by the front panel switch.   AC INPUT BREAKER (CIRCUIT BREAKER)   Illuminates when the   AC load exceeds the   Note! This connection is optional but highly suggested   as Internet, phone, fax lines often carry dangerous surges   and spikes and need to be protected. The UPS will still   work properly without a phone/fax/modem connection.   The 10-amp resettable circuit breaker button will be triggered   if an overload condition forces the UPS to disconnect   itself from utility power. If the black button sticks out,   disconnect nonessential equipment and depress breaker.   Solid Red LED   with Audible   Alarm (Beeping)   normal range. During this   condition, the LED will be lit   continuously, and the unit   will sound an audible alarm   intermittently until condition   is restored to normal.   FAULT/   *OVERLOAD   (Red LED)   Caution! The phone/fax/modem protection feature could   be rendered inoperable if improperly installed. Make   sure that the telephone line from the wall is plugged   into the connector marked “IN”, and the device to be   protected is plugged into the connector marked “OUT”.   SYSTEM REQUIREMENTS   The UPS can be used without the software and can be   used with any computer using a monitor or a flat-panel   screen. Also, you do not have to have the software   installed to utilize the battery backup outlets.   Indicates that surge   protection is working   properly. If this indicator is   not lit, you have lost your   surge protection. Please   consult your warranty   information and contact   Belkin Corporation.   Serial or USB Communication Port (Installation Optional)   To fully utilize the Shutdown Software; you will   need to connect the UPS to your computer so   they can communicate to each other.   PROTECTED   (Green LED)   Solid Green   To fully utilize the UPS and its software, your computer   must be able to operate the following operating systems:   Windows® 95, 98, 98SE, ME, NT® 4, 2000, XP, or   Linux® and higher and have a serial or USB port.   The communication port will provide the following features:   1. Monitoring charger status   INSTALLATION   Note!   Before installation, please inspect the UPS upon   receipt. Make sure that the UPS is not damaged.   2. Monitoring UPS status   ALARMS   Battery BACKUP (Slow Alarm)   When in the UPS is in battery backup mode, the On   Battery (Yellow LED) illuminates and the UPS sounds   an audible alarm every 10 seconds. The alarm stops   when the UPS returns to normal ONLINE operation.   3. Monitoring battery status and condition   4. Monitoring the utility status   5. Use the ON/OFF/TEST UPS power switch   function to schedule UPS for power saving   Connect to AC Utility Power   Connect the AC inlet to utility power via the power cord.   Charging the Battery   For best results, charge the battery for 6 hours prior to initial   use. The UPS charges its battery whenever it is connected   to the utility power. Should you see the yellow check battery   light come on, the battery may need immediate replacement.   Low Battery (Rapid Alarm)   You may connect the UPS to your computer by choosing   either the serial or USB ports with the selector.   When the UPS is in battery backup mode and the   battery energy begins to run low, the UPS will beep   every 1 second until it shuts down from a depleted   battery or returns to ONLINE normal operation.   Note: Choose one port only. Do not connect   your computer through both ports.   Download from Www.Somanuals.com. All Manuals Search And Download.   P74778uk_F6H350_500_650.indd   1 7/7/05 3:44:37 pm   |