Behringer Musical Instrument Amplifier 333 212 User Manual

A50-62313-00006  
333XL/333XL-212/333/333-212  
User Manual  
en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of contents  
en  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Make sure that children cannot play unsuper-  
vised with the unit or its packaging.  
$
$
IMPORTANT NOTICE!  
FAILURE TO OBSERVE THE FOLLOWING POINTS MAY RE-  
SULT IN DAMAGE TO THE AMPLIFIER OR LOUDSPEAK-  
ERS. DAMAGES CAUSED IN SUCH A WAY ARE NOT COV-  
ERED BY WARRANTY.  
Please ensure proper disposal of all packing  
materials.  
Ensure adequate air supply and to avoid overheating do  
not place the unit near radiators etc.  
Before you start, always make sure that your  
$
Bugera Valve Amplifier is connected to a suit-  
able loudspeaker. Observe the correct imped-  
ance for your loudspeaker and use the appro-  
priate output socket.  
Please make sure that all devices are properly  
$
grounded. For your own safety, never remove  
or disable the ground conductors from the de-  
vices or on the power cords. The unit must al-  
ways be connected to the mains outlet with a  
protective grounding connection.  
Always use loudspeaker cables for connection  
$
between the amplifier and the loudspeaker.  
Never use other types of cable, like instru-  
ment cable or microphone cable.  
The tone quality may diminish within the  
$
range of powerful radio broadcasting stations  
and high-frequency sources. Increase the dis-  
tance between the transmitter and the unit,  
and use shielded cables for all connections.  
Switching the amplifier on and off:  
Before connecting the amplifier to a power out-  
let, make sure that both POWER and STANDBY  
switches are set to the OFF position.  
$
Online registration  
Please do remember to register your new BUGERA equip-  
amps.com and kindly read the terms and conditions of  
our warranty carefully.  
Power on (mandatory):  
Switch the POWER switch on—wait for 60 sec-  
$
onds—then switch the STANDBY switch on.  
Should your BUGERA product malfunction, our goal is  
to have it repaired as quickly as possible. To arrange for  
warranty service, please contact the retailer from whom  
the equipment was purchased. Should your BUGERA  
dealer not be located in your vicinity, you may directly  
contact the BEHRINGER company nearest to you. This  
contact information is included in the original equip-  
ment packaging (Global Contact Information/European  
Contact Information). Should your country not be list-  
ed, please contact our exclusive distributor BEHRINGER  
Singapore (BEHRINGER Holdings (Pte) Ltd., 1 Kim Seng  
Promenade #08-08, Great World City West Tower, Sin-  
gapore 237994, Tel.: +65 6845 1800, Fax: +65 6214  
0275).  
Power off (recommended):  
Switch the STANDBY switch off—wait for 30  
seconds—then switch the POWER switch off.  
$
Note—after powering off we recommend that the ampli-  
fier is allowed to cool down for ten minutes before any  
attempt is made to move the amplifier. This reduces the  
risk of mechanical damage to the sensitive valve ele-  
ments.  
ATTENTION! TO AVOID DAMAGE TO YOUR  
AMP, NEVER USE THE BUGERA VALVE AM-  
PLIFIER WITHOUT A LOUDSPEAKER CON-  
NECTED!  
!
Registering your purchase and equipment with us helps  
us process your repair claims quicker and more efficient-  
ly.  
en  
Thank you for your cooperation!  
Introduction  
Congratulations! By purchasing the BUGERA, you have CAUTION!  
chosen a state-of-the-art valve amplifier.  
Please note that high volume levels may cause  
$
This 120-Watt full-valve amp offers you 3 full-fledged  
channels with 3 tone controls, a separate switchable Ef-  
fects Loop plus integrated Reverb and much more. This  
way you’re in full control and can get down to the nitty-  
gritty—your music! Discover the sound of the BUGERA  
and be inspired by its versatility. Whatever style you  
play, this monster amp gives you the full valve power  
that you require.  
permanent damage to your hearing and/or  
your loudspeakers. Turn the MASTER control  
to the left before switching on the unit. Be sure  
to keep the volume at an appropriate level.  
Before you get started  
Your product was carefully packed at the factory to en-  
sure safe transport. Nevertheless, if the box is damaged  
inspect the unit immediately for signs of damage.  
If the unit is damaged please do NOT return it  
$
to us, but notify your dealer and the shipping  
company immediately; otherwise, claims for  
damage or replacement may not be granted.  
Always use the original box to prevent dam-  
age during storage or transport.  
$
Introduction  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Control elements  
Front panel of the BUGERA 333XL  
12 The BASS controls of the LEAD and CRUNCH chan-  
Front panel  
nels adjust the lower frequency range (active shelv-  
ing control for up to 15 dB boost/cut).  
1
The POWER switch is used to turn the power of the  
BUGERA amplifier on and off.  
13 The GAIN control lets you determine the input lev-  
el of the LEAD and CRUNCH channels (the CLEAN  
channel doesn’t feature a GAIN control). Turn the  
control to the right to increase the preamplifier’s  
distortion and sustain.  
2
The STANDBY switch allows you to place the amp  
in STANDBY mode. This way the amp is idle, but  
the operational temperature of the valves is main-  
tained (POWER switch turned on). Flick the STAND-  
BY switch to change to the active mode (the above  
status light illuminates).  
Please note that extremely high GAIN and  
$
VOLUME settings in conjunction with high  
MASTER settings can make the combo mod-  
els vibrate mechanically. This may occur when  
played at extremely high volume levels, which  
is seldom done. Should this be the case, ad-  
just the GAIN and VOLUME settings so that the  
problem does not recur.  
ATTENTION! TO AVOID DAMAGE TO YOUR  
AMP, NEVER USE THE BUGERA VALVE AM-  
PLIFIER WITHOUT A LOUDSPEAKER CON-  
!
NECTED!  
3
The MASTER control adjusts the volume level of  
the BUGERA. First, bring the levels of the ampli-  
fier’s three channels into line and only then specify  
the overall level with the MASTER control. Turn the  
control to the right to increase the volume; turn it  
to the left to reduce the volume.  
14 The XL switches of the LEAD and CRUNCH channels  
change the amplifier’s response at low frequencies  
(only 333XL and 333XL-212). It fattens up the tone  
by providing more low-end.  
15 The LEAD switch activates the LEAD channel (switch  
4
The PRESENCE control modifies the amp’s damping  
factor at high frequencies (only 333XL and 333XL-  
212). This is used to fine-tune the high-frequency  
range of the speaker cabinet.  
glows red).  
16 The CRUNCH switch activates the CRUNCH channel  
(switch glows yellow).  
en  
17 The passive TREBLE control adjusts the upper fre-  
5
6
7
The REVERB control determines the amount of the  
built-in reverb effect.  
quency range of the CLEAN channel.  
18 The passive MID control adjusts the mid frequency  
The REVERB switch activates the REVERB effect  
(switch glows yellow).  
range of the CLEAN channel.  
19 The passive BASS control adjusts the lower fre-  
The FX LOOP/BOOST switch activates the FX LOOP  
and the BOOST function (switch glows green).  
quency range of the CLEAN channel.  
20 The CLEAN switch activates the CLEAN channel  
You can also activate the FX LOOP with the  
supplied footswitch. Refer to „Footswitch“ for  
details.  
$
(switch glows red).  
You can activate the three channels with the  
supplied footswitch. Refer to „Footswitch“ for  
details.  
$
8
The NOISE GATE control determines the effect the  
NOISE GATE filter has on the LEAD and CRUNCH  
channels (only 333XL and 333XL-212). The further  
you turn the control to the right, the more noise  
is reduced. At low GAIN settings, the NOISE GATE  
shouldn’t be set too high or else the tones’ sustain  
is affected.  
21 The HIGH GAIN input (333 and 333-212: INPUT)  
is 6 dB louder than the LOW GAIN input and is used  
for most electric guitars.  
22 The LOW GAIN input is used for instruments with  
an extremely high output level which could distort  
the HIGH GAIN input (only 333XL and 333XL-212).  
9
The VOLUME controls adjust the volume levels of  
all three amplifier channels.  
The HIGH GAIN and LOW GAIN connectors  
have identical sensitivity when used at the  
same time (both with LOW GAIN sensitivity).  
$
10 The TREBLE controls of the LEAD and CRUNCH  
channels adjust the upper frequency range (active  
shelving control for up to 15 dB boost/cut).  
11 The MID controls of the LEAD and CRUNCH chan-  
nels adjust the mid-frequency range (active peak/  
notch control for up to 15 dB boost/cut).  
Control elements  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Rear panel of the BUGERA 333  
29 The IMPEDANCE switch lets you specify the loud-  
Rear panel  
CAUTION!  
!
speaker impedance. Always apply the value that  
is identical to the impedance of the used speaker  
cabinet. When connecting two cabinets with the  
same impedance, the switch should be set to half  
the value of one of the cabinets. For example, two  
16-Ohm cabinets would require an 8-Ohm setting,  
while two 8-Ohm cabinets need to be set to the  
minimum impedance of 4 Ohms. Please also read  
„Wiring the BUGERA“.  
Hot! Risk of injury! During use, the valves  
get very hot and high surface temperatures  
may be reached at the rear of this unit.  
Avoid touching the controls and connectors  
on the rear panel during use. To avoid acci-  
dental contact with hot surfaces, place the  
rear panel so that it faces a wall.  
!
30 Both the paralleled LOUDSPEAKER outputs (¼"  
mono jacks) are used to connect the speaker  
cabinet(s). The minimum impedance is 4 Ohms. The  
IMPEDANCE switch should always be set to match  
the impedance of the used speaker cabinet.  
23 The calibrated LEVEL control determines the signal  
level sent to an external effects unit or any other  
signal processor (0 – 10). Turn the control to the  
right to increase the amount of signal information,  
and turn it to the left to decrease the amount. It  
makes sense to select a high setting in order to  
get a possibly noise-free signal. The FX Send Level  
and FX Return Level (26) controls should always be  
set oppositely. For example, to reach a 0 dB work-  
ing level when the FX Send Level is set low, the FX  
Return Level (26) needs to be set high accordingly.  
On the other hand, if you wish to boost the volume  
level, turn both controls to a higher setting.  
ATTENTION! TO AVOID DAMAGE TO YOUR  
AMP, NEVER USE THE BUGERA VALVE AM-  
PLIFIER WITHOUT A LOUDSPEAKER CON-  
NECTED!  
!
31 This is the LEVEL control that specifies the signal  
level for the OUT (32) in order to adjust the level  
of a second amplifier and loudspeaker system con-  
nected over the OUT to the LOUDSPEAKER outputs  
(30) of one or more connected speaker cabinets.  
24 The SEND output is used to connect a shielded ¼"  
mono jack cable to the input of an external effects  
unit.  
32 The OUT provides a preamp signal in order to feed  
the signal to a second amplifier and loudspeaker  
system, for example.  
25 The RETURN input is used to connect a shielded  
¼" mono jack cable to the output of an external  
effects unit.  
en  
26 The calibrated LEVEL control determines the signal  
level returned from an external effects unit or any  
other signal processor (0 – 10). Turn the control  
to the right to increase the amount of signal in-  
formation, and turn it to the left to decrease the  
amount. To achieve a possibly noise-free signal, set  
the FX Send Level (23) relatively high and the FX  
Return Level relatively low. A BOOST effect can be  
achieved with this LEVEL control when the RETURN  
input isn’t being used. Increase the volume level  
with this control plus activate the FX LOOP with the  
footswitch in order to make the guitar signal louder.  
This function is great for highlighting solos.  
*
33 WARNING: ONLY REPLACE THE FUSE WHEN THE  
MAINS CABLE HAS BEEN DISCONNECTED! The  
FUSE is found in the fuse holder. If the fuse is  
blown, it needs to be replaced with a fuse of the  
same kind by all means. Otherwise, the unit could  
seriously be damaged, in which case the warranty  
is void. If the fuse is blown repeatedly, you should  
take the unit to a qualified service technician.  
*
34 The IEC MAINS connector is used to connect the  
mains cable that has the appropriate voltage rat-  
ings for your country (included). At all times, make  
the connections to the amplifier before plugging the  
cable into a power outlet.  
27 The 7-pin FOOTSW(itch) connector is provided  
to connect to the supplied BUGERA FSB104 foot-  
switch. Please be sure to connect the cables before  
switching on the amplifier. Refer to „Footswitch“ for  
details.  
35 This is the SERIAL NUMBER of the amplifier.  
28 The DAMPING switch lets you specify the damping  
factor of the BUGERA (only 333 and 333-212). The  
term „damping“ refers to a feature of the ampli-  
fier that affects the signal’s fade-out phase. A high  
damping factor (HIGH) makes the signal fade out  
quicker than a low factor (LOW). Changes to the  
damping factor automatically result in level altera-  
tions which should be re-adjusted.  
Control elements  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Inside the BUGERA 333  
Footswitch  
Inside the BUGERA  
DANGER!  
*
High voltage! Risk of death!  
High voltages of up to 500 V DC may be  
present inside the casing for long periods  
after being disconnected from the mains.  
To avoid lethal electric shock, do not open  
the casing. There are no user-serviceable  
components inside. Refer all maintenance  
to qualified service personnel. Remove the  
mains cable when the unit is not in use.  
The parts inside the amplifier operate at  
high voltages and high temperatures. To  
avoid damage and injury that results from  
fire or electric shock, do not drop or spill  
anything into the unit’s casing.  
*
Footswitch BUGERA FSB104  
Instructions for qualified service  
personnel only  
Remove the backside of the amplifier’s casing to get to  
en  
36 The 7-pin DIN connector is provided to connect  
the footswitch cable (included). Then, the cable is  
connected to the FOOTSW(itch) connector of the  
BUGERA amplifier. Be sure to make a connection  
before switching on the amplifier.  
the valves and the control elements.  
41 These are the sockets for the 12AX7A/B/C pre-  
37 The CLEAN switch activates the CLEAN channel. Its  
amp valves.  
LED illuminates when the channel is active.  
42 These are the sockets for the 6L6 and EL34 power  
amp valves. Please take care that the BIAS SELECT-  
switch (43) is set correctly. The models 333 and  
333-212 are supplied with 6L6GC power amp valves  
when it leaves the factory. The models 333XL and  
333XL-212 incorporate EL34 power amp valves.  
38 The CRUNCH switch activates the CRUNCH chan-  
nel. Its LED illuminates when the channel is active.  
39 The LEAD switch activates the LEAD channel. Its  
LED illuminates when the channel is active.  
40 The FX LOOP switch activates the FX LOOP and the  
BOOST function. Its LED illuminates when the FX  
LOOP is active.  
43 The BIAS SELECT switch allows the amplifier to  
optimally adapt to the used valves (6L6 or EL34).  
*
44 The BIAS TEST connector lets you connect a volt-  
meter in order to measure the power amp valves  
(bias adjustment). Make sure that the voltmeter is  
set to direct current (DC).  
45 The BIAS ADJUST control is used to make the bi-  
as-adjustment.  
Replacing the power amp valves also requires  
$
bias adjustment. You should always use sets  
of four matched valves. The valves of the  
BUGERA Series are ideal for this purpose.  
Control elements  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAUTION: WE HIGHLY RECOMMEND THAT  
BIAS ADJUSTMENTS BE CARRIED OUT BY  
QUALIFIED PERSONNEL!  
!
Wiring the BUGERA  
CAUTION!  
!
Hot! Risk of injury! During use, the valves  
will get very hot and high surface temper-  
atures may be reached at the rear of this  
unit. To avoid burning yourself, make all  
connections while the unit is still cold.  
ATTENTION! TO AVOID DAMAGE TO YOUR  
AMP, NEVER USE THE BUGERA VALVE AM-  
PLIFIER WITHOUT A LOUDSPEAKER CON-  
NECTED!  
!
The BUGERA amplifier has two paralleled LOUDSPEAKER  
outputs which are used to connect one or two speaker  
cabinets.  
If you only connect one speaker cabinet, be sure that the  
IMPEDANCE switch is set to match the impedance of the  
connected cabinet.  
BUGERA head with a speaker cabinet  
If you want to connect two speaker cabinets, both cabi-  
nets should have to the same impedance. Be sure to  
have set the IMPEDANCE switch correctly. In this case,  
set it to half the value of one of the cabinets. When us-  
ing two  
16-Ohm cabinets, the switch therefore needs to be set  
to 8 Ohms; and with two 8-Ohm cabinets, set it to the  
minimum impedance of 4 Ohms.  
CAUTION: The loudspeakers in the combos are connect-  
ed in series. This results in an impedance of 16 Ohms.  
en  
Impedances  
Wiring the BUGERA  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The following figure shows a setup of the 333XL-212 to-  
gether with an external effects unit connected over the  
FX LOOP. And the LINE OUT is connected to the line input  
of a mixer in order to send the signal to a recording de-  
vice. The LEVEL control of the LINE OUT lets you adjust  
the output level of the BUGERA to the input sensitivity of  
the mixer. In addition, the speaker signal of the BUGERA  
is picked up by a microphone and is fed to the micro-  
phone input of the mixer. This way you get a second  
guitar signal which then can be amplified by a PA system  
and/or can be recorded as well.  
Audio connections  
The inputs and outputs of the BUGERA amplifier use  
mono jack connectors.  
¼" mono jack connector  
en  
Live setup with a BUGERA combo  
Audio connections  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Specifications  
PREAMP SECTION  
Valves  
Type  
1 x 12AX7A  
1 x 12AX7B  
2 x 12AX7C  
Preamp high-gain input  
Impedance  
470 kΩ  
Clean channel  
Nominal input level  
Min. input level  
Max. input level  
Crunch channel  
Nominal input level  
Min. input level  
-20 dBV  
-30 dBV  
0 dBV  
-80 dBV  
-90 dBV  
Lead channel  
Nominal input level  
Min. input level  
-80 dBV  
-90 dBV  
Preamp low-gain input (only 333XL and 333XL-212)  
Impedance  
44 kΩ  
All levels attenuated by  
Effects send  
+6 dB  
Impedance  
47 kΩ or higher  
Min. output level  
Max. output level  
Effects return  
Impedance  
Min. input sensitivity  
Max. input sensitivity  
Line output  
-10 dBV, 300 mV RMS  
0 dBV, 1 V RMS  
470 kΩ  
-10 dBV  
0 dBV  
Impedance  
47 kΩ or higher  
Adjustable output level  
±20 dBV  
POWER AMPLIFIER SECTION  
Valves  
Type  
4 x 6L6GC (333 and 333-212)  
4 x EL34 (333XL and 333XL-212)  
Output power  
Peak power  
120 W / 16, 8, 4 Ω  
Loudspeaker connectors  
Type  
¼" mono jack connectors, unbalanced  
Load impedance  
4 Ω / 8 Ω / 16 Ω switchable  
Internal loudspeakers (only 333XL-212 and 333-212)  
Type  
Impedance  
2 x 12" BUGERA, 12G70J8  
8 Ω  
en  
Continuous power  
Total impedance  
70 W (IEC)  
16 Ω (series connection)  
POWER SUPPLY  
U.S./Canada  
China  
120 V~, 60 Hz  
220 V~, 50 Hz  
Korea  
220 V~, 60 Hz  
Europe/U.K./Australia  
Japan  
230 V~, 50 Hz  
100 V~, 50/60 Hz  
General export model  
Power consumption  
Fuse  
120/230 V~, 50/60 Hz  
Max. 350 W  
T 3.15 A H 250 V (100 – 120 V~, 50/60 Hz)  
T 1.6 A H 250 V (220 – 230 V~, 50/60 Hz)  
Standard IEC receptacle  
Mains connection  
DIMENSIONS/WEIGHT  
333  
Dimensions (H x W x D)  
Weight  
Approx. 9 25/32" x 27" x 9 11/16" (249 mm x 687.3 mm x 246 mm)  
Approx. 47 lbs (21.5 kg)  
333-212  
Dimensions (H x W x D)  
Weight  
Approx. 20 13/32" x 27" x 9 3/4" (518.46 mm x 687.3 mm x 247.65 mm)  
Approx. 63 lbs (28.5 kg)  
333XL  
Dimensions (H x W x D)  
Weight  
Approx. 9 25/32" x 27" x 9 11/16" (249 mm x 687.3 mm x 246 mm)  
Approx. 47 lbs (21.5 kg)  
333XL-212  
Dimensions (H x W x D)  
Weight  
Approx. 20 13/32" x 27" x 9 3/4" (518.46 mm x 687.3 mm x 247.65 mm)  
Approx. 63 lbs (28.5 kg)  
We are constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be made from time to time to  
existing products without prior notice. Specifications and appearance may differ from those listed or illustrated.  
Specifications  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Limited warranty  
SPECIAL NOTE: NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY.  
§ 1 Other warranty rights and national law  
1. This limited warranty does not exclude or limit the buyer’s statutory rights provided by national law, in particular, any such rights against the seller that  
arise from a legally effective purchase contract.  
2. The limited warranty regulations mentioned herein are applicable unless they constitute an infringement of national warranty law.  
§ 2 Online registration  
and conditions of our limited warranty carefully. Registering your purchase and equipment with us helps us process your repair claims quicker and more  
efficiently. Thank you for your cooperation!  
§ 3 Limited Warranty  
1. BEHRINGER warrants the mechanical and electronic components of this product to be free of defects in material and workmanship if used under normal  
operating conditions for a period of one (1) year** from the original date of purchase.  
2. BEHRINGER warrants valves (tubes) and meters contained in the product to be free of defects in material and workmanship if used under normal operat-  
ing conditions for a period of 90 days from the original date of purchase.  
3. This limited warranty is subject to the conditions, exclusions and limitations hereinafter set forth.  
4. If the product shows any defects within the specified warranty period that are not excluded from this warranty as described under § 5, BEHRINGER will,  
at its discretion, either replace the product by providing a new or reconditioned product or repair the product using suitable new or reconditioned parts.  
In the case that other parts are used which constitute an improvement, BEHRINGER may, at its discretion, charge the customer for the additional cost  
of these parts. In case BEHRINGER decides to replace the entire product, this warranty shall apply to the replacement product for the remaining initial  
warranty period, i.e., one year** from the date of purchase of the initial product.  
5. If the warranty claim proves to be justified, the product will be returned to the user freight prepaid.  
6. Warranty claims other than those indicated above are expressly excluded.  
PLEASE RETAIN YOUR SALES RECEIPT, AS IT IS YOUR PROOF OF PURCHASE COVERING YOUR LIMITED WARRANTY. THIS LIMITED WARRANTY IS VOID  
WITHOUT SUCH PROOF OF PURCHASE.  
§ 4 Return authorization number  
1. To obtain warranty service, the buyer (or his authorized dealer) must call BEHRINGER as exclusive distributor of BUGERA products (see enclosed list)  
during normal business hours BEFORE returning the product. All inquiries must be accompanied by a description of the problem. The buyer or his au-  
thorized dealer will receive a return authorization number  
2. Subsequently, the product must be returned in its original shipping carton, together with the return authorization number. The return shipment address  
will be indicated by BEHRINGER.  
3. Shipments without freight prepaid will not be accepted.  
§ 5 Warranty regulations  
1. Warranty services will be furnished only if the product is accompanied by a copy of the original retail dealer’s invoice.  
2. If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level, in any country  
which is not the country for which the product was originally developed and manufactured, this modification/adaptation shall not be considered a defect  
in materials or workmanship. This limited warranty does not cover any such modification/adaptation, irrespective of whether it was carried out properly  
or not. Under the terms of this limited warranty, BEHRINGER shall not be held responsible for any cost resulting from such a modification/adaptation.  
3. Free inspections and maintenance/repair work are expressly excluded from this limited warranty, in particular, if caused by improper handling of the  
product by the user. This also applies to defects caused by normal wear and tear, in particular, of faders, crossfaders, potentiometers, keys/buttons,  
tubes, guitar strings, illuminants and similar parts.  
4. Damage/defects caused by the following conditions are not covered by this limited warranty:  
>
>
improper handling, neglect or failure to operate the unit in compliance with the instructions given in BEHRINGER user or service manuals  
connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the  
product is used.  
>
damage/defects caused by force majeure or any other condition that is beyond the control of BEHRINGER.  
en  
5. Any repair or service performed by any person or entity other than a BEHRINGER authorized service center is not covered by this limited warranty.  
6. Any repair or opening of the unit carried out by unauthorized personnel (user included) will void this limited warranty.  
7. Any exchange of the tubes/valves and associated biasing by any person or entity other than a BEHRINGER authorized service centre will void this limited  
warranty.  
8. If an inspection of the product by BEHRINGER shows that the defect in question is not covered by this limited warranty, the inspection costs are payable  
by the customer.  
9. Products which do not meet the terms of this limited warranty will be repaired exclusively at the buyer’s expense. BEHRINGER will inform the buyer of  
any such circumstance. If the buyer fails to submit a written repair order within 6 weeks after notification, BEHRINGER will return the unit. Costs for  
freight and packing will be invoiced separately C.O.D. When the buyer has sent in a written repair order, such costs will also be invoiced separately.  
§ 6 Warranty transferability  
This limited warranty is extended exclusively to the original buyer (customer of retail dealer) and is not transferable to anyone who may subsequently  
purchase this product.  
§ 7 Claim for damages  
Failure of BEHRINGER to provide proper warranty service shall not entitle the buyer to claim (consequential) damages. In no event shall the liability of  
BEHRINGER exceed the invoiced value of the product.  
§ 8 U.S. Customers only  
THE FOREGOING CONSTITUTES THE ONLY WARRANTY MADE BY BEHRINGER WITH RESPECT TO THE PRODUCT AND IS MADE EXPRESSLY IN LIEU OF ALL  
OTHER WARRANTIES EXPRESS OR IMPLIED. Any implied warranties, including without limitation, any implied warranties of merchantability or fitness for  
any particular purpose, imposed under state law are limited to the duration of this limited warranty. Some states do not allow limitations on how long an  
implied warranty lasts, so the above limitations may not be applicable to you.  
BEHRINGER ASSUMES NO LIABILITY FOR PROPERTY DAMAGE RESULTING FROM FAILURE OF THIS PRODUCT NOR ANY LOSS OF INCOME, SATISFACTION  
OR DAMAGES ARISING FROM THE LOSS OF USE OF SAME DUE TO DEFECTS OR AVAILABILITY OF SAME DURING SERVICE.  
**Customers in the European Union please contact BEHRINGER Germany Support for further details.  
Technical specifications and appearance are subject to change without notice. The information contained herein is correct at the time of printing. All trade-  
marks (except BUGERA, the BUGERA logo, and THE SOUL OF VALVES) mentioned belong to their respective owners, and such use neither constitutes a  
claim of the trademarks by RED CHIP COMPANY LTD nor affiliation of the trademark owners with RED CHIP COMPANY LTD. RED CHIP COMPANY LTD accepts  
no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph or statement contained  
herein. Colors and specifications may vary slightly from product. Our Products are sold through authorized dealers only. This manual is copyrighted. No part  
of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording of any kind,  
for any purpose, without the express written permission of RED CHIP COMPANY LTD. BUGERA-products are distributed exclusively by the BEHRINGER Group  
of companies globally, and specifically by BEHRINGER International GmbH in the European Union. ALL RIGHTS RESERVED. (c) 2008 RED CHIP COMPANY  
LTD. Trident Chambers, Wickhams Cay, P.O. Box 146, Road Town, Tortola, British Virgin Islands.  
Limited warranty  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Abocom Network Card WB1500SH User Manual
AEG Washer Dryer 12710 User Manual
Alesis CD Player Vocalist User Manual
Alto Shaam Food Warmer EC2 72 User Manual
American Dryer Corp Clothes Dryer 20 31 User Manual
Asus Computer Hardware 90MB0DR0M0AAY0 User Manual
Aztech Systems Network Router DSL605ER User Manual
Baracoda Barcode Reader BC2604 User Manual
Beko Air Conditioner BK 5200 User Manual
Eureka Tents Tent Condo User Manual