BB Electronics Network Card HVD100A3 User Manual

Model: HVD100A3  
HDV100A3 Command  
Response Protocol  
Documentation Number: HDV100A3-4407CR  
International Headquarters  
B&B Electronics Mfg. Co. Inc.  
707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA  
Phone (815) 433-5100 -- General Fax (815) 433-5105  
Sales e-mail: [email protected] -- Fax (815) 433-5109  
Technical Support e-mail: [email protected] -- Fax (815) 433-5104  
© B&B Electronics -- November 2005  
HDV100A3 Command & Response Manual-1306cr  
Cover Page  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
INTRODUCTION........................................................................................ 1  
Intelligent Mode Command Protocol..................................................... 2  
Formatting the Control Bytes ................................................................ 3  
DETAILED DESCRIPTION OF GENERAL FUNCTION CODES...... 4  
Command Acknowledgement................................................................. 4  
RS-232 Baud Rate Setup ........................................................................ 5  
Setting Baud 1, Baud 2........................................................................... 7  
Baud Rate Example................................................................................ 8  
Time Stamp Information ........................................................................ 9  
Master Reset Command ....................................................................... 11  
Vendor Information.............................................................................. 11  
J1708 COMMANDS.................................................................................. 12  
Receiving Data from the J1708 Bus..................................................... 12  
Transmitting Data to the J1708 Bus .................................................... 14  
Set Filter Active.................................................................................... 16  
Set Filter Off ........................................................................................ 16  
Broadcast Message .............................................................................. 17  
J1939 COMMANDS.................................................................................. 19  
Start Receive on J1939 Bus.................................................................. 20  
Stop Receive on J1939 Bus .................................................................. 20  
Arbitration Field (Y1, Y2, Y3, Y4)........................................................ 21  
Transmit Data to J1939 Bus ................................................................ 23  
Set Mask............................................................................................... 23  
Set Filter 1 to 4 .................................................................................... 24  
J1939 Header Worksheet..................................................................... 26  
ERROR CODES ........................................................................................ 27  
HDV100A3 Command & Response Manual-1306cr  
Table of Contents  
i
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING!  
This Model HDV100A3 Converter Module allows  
you to connect to active J1708 / J1939 networks.  
It is possible that your transmissions through this  
converter module could cause malfunction of the  
network operation, damage to software or  
equipment, or bodily harm.  
Do Not Transmit Any Messages to the network  
without a complete understanding  
of the operation of the network.  
B&B Electronics Mfg. Co. specifically disclaims  
any responsibility for damage or injury to  
software, hardware, equipment or persons as a  
result of using this product.  
WARNING!  
ii  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
The HDV100A3 adapter has two modes of operation: J1708 Intelligent and  
J1939 Intelligent mode In Intelligent mode the HDV100A3 works with a  
command protocol to control different operations of the HDV100A3.  
The HDV100A3 performs several functions in the intelligent mode in order  
to reduce the overhead and timing requirements of the host application when  
communicating with the J1708 bus. The device handles collision detection  
and retries with no additional interaction from the host application. This  
greatly reduces the processor overhead required by the host in order to  
communicate efficiently with the J1708 bus.  
Note that the HDV100A3 is powered from the vehicle side of the interface.  
If the device is to be used without a vehicle, it will be necessary to connect  
power to the device through the 15-pin connector. Positive voltage is  
connected on pin 8. Pin 7 is connected to ground.  
Intelligent Mode Verification  
To confirm that the HDV100A3 is in the Intelligent mode, set the host baud  
rate to 115.2 KB 8,1,N. The host application can request the vendor number  
from the HDV100A3 This is done by sending the following string in hex  
from the host to the HDV100A3:  
(01, 01, 05, 00, 07)  
It will respond as follows:  
Hex (01, 0B, 85, MM, DD, MA, M1, M2, MO, 00, VV, VV, 00, DB, CS)  
An example of this command can be found on page 12 of this document.  
The HDV100A3 does not need to be connected to a vehicle to respond,  
however power must be supplied the HDV100A3.  
HDV100A3 Command & Response Manual-1306cr  
1
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Mode Command Protocol  
The HDV100A3 uses a simple protocol to communicate to vehicle bus. The  
protocol is divided into four parts:  
Start Of Frame (SOF)  
Control Field (shown in light gray)  
Data Field (shown in dark gray)  
Checksum (CS)  
Intelligent Mode Message Structure  
SOF  
Number of  
Control Bytes  
1 byte  
Control Bytes Number of  
Data Bytes  
Data Bytes  
CS  
1 byte  
1 to 20 bytes  
1 byte  
1 to 100 bytes 1 byte  
The Start of Frame byte is the first byte in a valid frame and is  
always 01 hex.  
The Control Field sets up the function and control of the  
HDV100A3 hardware and is formatted as shown below.  
Control Field Structure  
Number of Control ID Byte Function  
Control Data Bytes  
Up to 20 bytes  
Bytes to Follow  
Byte  
1 byte  
1 byte  
1 byte  
The first byte of the Control Field is the number of control bytes in  
the message. This value indicates the number of control bytes, excluding  
itself, to follow. If the message doesn’t contain any control bytes, the  
Number of Control Bytes value will be set to 00 hex as a placeholder.  
The next part of the message frame is the data field. The data field  
is preceded by the number of data bytes, excluding itself, to follow and is set  
to 00 hex if no data is present in the message. The data field is reserved for  
data that is to be communicated to the vehicle bus.  
Data Field Structure  
Number of  
Data Bytes  
1 byte  
Data Bytes  
Up to 100 bytes  
The last element of a valid message is the checksum. The checksum  
is calculated by adding ALL bytes from the Start of Frame (inclusive) to the  
last data byte and using the last 8 bits as a checksum.  
2
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Formatting the Control Bytes  
The 2nd byte is “Number of Control Bytes” to follow and always  
precedes the control field. The third byte is the ID byte. This byte tells the  
hardware where to direct the message. Valid entries for functions are:  
ID Codes  
=01 Message for J1708  
=02 Message for J1939  
=08 General message (for control of the HDV100A3 device)  
=05 Device identification (reverse compatible)  
The fourth byte is the function byte. The functions that are  
supported are listed below. Note that some of the function codes are  
followed by additional bytes of information. These bytes must be included in  
the control byte count.  
Valid General Function Codes  
Function codes  
=01 change PC baud rate, followed by 3 bytes (UB3, Baud1, Baud2)  
=02 send time stamp  
=04 hardware handshaking  
=08 reset converter, followed by 2 bytes (01,and 02)  
=10 time stamp off  
=20 time stamp on  
Valid Entries for J1708 Functions  
Function codes = 07 set broadcast message  
= X8 set filter X off  
= X9 set filter X on  
= 11 Sync with J1708 bus and start reception  
= 10 Stop reception  
= 12 Transmit to J1708 bus  
Valid Entries for J1939 Functions  
Function codes  
=00 Receive off  
=01 Receive on  
=02 Transmit message  
=08 Set mask  
=X8 set filter X off  
=X9 set filter X on  
HDV100A3 Command & Response Manual-1306cr  
3
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Detailed Description of General Function Codes  
Command Acknowledgement  
All commands sent to the device will be acknowledged. If no error occurs an  
ACK will be sent with the ID byte that accompanied the command. If an  
error occurred, a NACK will be sent with the ID byte that accompanied the  
command as well as a Function code of $05 and the Error Code. The  
responses will not be shown for each command since it is the same for  
almost all commands. Below is the format of the ACK/NACK response. If  
an ACK/NACK response is different for a particular command, it will be  
specified.  
ACK/NACK Format:  
Byte  
Number  
Byte  
Value  
01  
Function  
1
2
3
4
5
6
7
Start of frame  
01 or 03 Number of control bytes = 1 for ACK, 3 for NACK  
aa  
bb  
cc  
00  
CS  
ID byte 08 = internal command  
Function code 02 = send time stamp  
Number data bytes  
Checksum  
aa – ID Byte  
$01 = J1708 Interface  
$02 = J1939 Interface  
$05 = Device Id  
$08 = RS-232 Interface  
$09 = Message Xmit OK Response  
bb – FC Byte  
None = Command Received and Valid  
$05 = A error was detected, NACK  
cc – CD Byte  
None = No Error Condition  
Error Code = See Section 5.10  
4
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Baud Rate Setup  
To set the baud rate for the RS-232 port, set a general command code of 08.  
Set the function code to 01. Then set 3 control bytes as follows.  
Function Start Control Command Function UB3 Baud Baud Data Check  
of  
Bytes Code  
Code  
1
2
Bytes Sum  
Frame  
Byte #  
Value  
1
01  
2
05  
3
08  
4
01  
5
6
8
9
00  
10  
Setting UB3  
Bit 7  
Divisor  
Latch  
Bit 6  
Set  
Break  
Bit 5  
Set  
Parity  
Bit 4  
Even  
Parity  
Bit 3  
Parity  
Enable Bits  
Bit 2  
Stop  
Bit 1  
Word  
Length 1 Length 0  
Bit 0  
Word  
Bit 7 = 1 allows baud rate divisor to be changed. 0 baud rate change is  
blocked. Bit 7 should not be set. The setting and resetting of this bit is  
handled internally.  
Bit 6 = 1 forces the transmitter output to a logic 0 for alerting the remote  
receiver to a line break. 0 indicates no break condition.  
Bit 5, 4 and 3 work together to set parity  
Bit 5  
Bit 4  
Bit 3  
Parity Selection  
No parity (default)  
Odd parity  
Even parity  
Force parity “1”  
Force parity “0”  
*
0
0
1
1
*
0
1
0
1
0
1
1
1
1
*Don’t care state.  
Bit 2, stop bit, works in conjunction with bits 1 and bit 0  
Bit 2  
Word Length (bits) Stop Bit Length  
0
1
1
5,6,7,8  
5
6,7,8  
1 (default)  
1½  
2
HDV100A3 Command & Response Manual-1306cr  
5
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bits 1 and 0 set the word length  
Bit 0  
Bit 1  
Word Length  
0
0
1
1
0
1
0
1
5
6
7
8 (default)  
Default value. The HDV100A3 should always be set to 8-bit word length.  
6
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Baud 1, Baud 2  
Baud Rate Setup Table  
Baud  
Rate  
9600  
14400  
19200  
38,400  
57,600  
115,200  
230,400  
460,800  
Decimal  
Divisor  
Hex Divisor MSB  
Hex Divisor LSB  
(Baud 2)  
$00 (default)  
$00  
(Baud 1)  
$30 (default)  
$20  
48  
32  
24  
12  
8
4
2
1
$00  
$00  
$00  
$00  
$00  
$00  
$18  
$0C  
$08  
$04  
$02  
$01  
All baud rates are entered as hex numbers. To calculate your own  
decimal divisor use the following formula. The decimal number must be  
converted to hexadecimal before entering the number. Baud rates below  
9,600 are not recommended because of the difference in speed between the  
vehicle bus and PC serial port. Additionally, baud rates faster than 115,200  
baud are not supported.  
The UART clock = 7,372,800 Hz  
Decimal Divisor = Clock frequency ( 7,372,800)  
Baud output x 16  
If you want a baud rate of 9,600 baud  
Decimal Divisor = 7,372,800  
9,600 x 16  
Decimal Divisor = 48 = 30 hex  
Baud 1= 30  
Baud 2= 00  
HDV100A3 Command & Response Manual-1306cr  
7
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Baud Rate Example  
To set the PC baud rate to 57,600 baud, N,8,1, format the message as  
follows.  
Byte  
Number Value  
Hex  
Byte  
Byte Function  
1
2
3
4
5
6
7
8
9
01  
05  
08  
01  
03  
08  
00  
00  
1A  
Start of frame  
Number of control bytes  
Command byte (08 = internal command)  
Function Bbte (01 = change baud)  
UB3  
Baud 1  
Baud 2  
Number of data bytes  
Checksum  
The first byte is the start of frame and always 01. Next is the  
number of control bytes (05). There are 5 bytes in the control section (in  
gray). Byte number 3 sets the HDV100A3 to an internal operation (08). Byte  
4 is the internal function to be executed; (01) is the change baud command.  
Bytes 5, 6, and 7 set the baud rate, parity, stop bits and word length. Next is  
the number of data bytes, in this case there are no data bytes. Last is the  
checksum, the value is the 8 bit addition of bytes 1 to 8.  
8
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Time Stamp Information  
The HDV100A3 supports a four-byte rolling time stamp with a  
resolution of 1.5 microseconds per bit. The maximum time stamp value is  
6,442.45 seconds before roll over. The 4-byte time stamp will be added to all  
transmission from the bus. The time stamp will be added to the transmission  
confirmation message.  
The host application can request that the HDV100A3 send a time  
stamp, formatted as follows.  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
5
6
01  
02  
08  
02  
00  
0D  
Start of frame  
Number of control bytes  
ID byte 08 = internal command  
Function code 02 = send time stamp  
Number data bytes  
Checksum  
Reply from HDV100A3  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
5
6
7
8
9
01  
05  
Start of frame  
Number of control bytes  
ID 0A = time stamp  
Time msb  
Time msb-1  
Time msb – 2  
Time lsb  
0A  
XX  
XX  
XX  
XX  
00  
Data bytes 00  
Checksum  
CS  
The time stamp is attached to all messages received from the  
vehicle bus as part of the control header. After the start of frame byte, the  
number of control bytes, ID byte and the next 4 bytes are the time stamp.  
The fourth byte is the MSB the seventh byte is the LSB.  
Message time stamping is the default condition when the  
HDV100A3 is placed in the smart mode. To stop the time stamp from being  
added to the J1708 message, send the following command to the  
HDV100A3.  
HDV100A3 Command & Response Manual-1306cr  
9
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
5
6
01  
02  
08  
20  
00  
2B  
Start of frame  
Number of control bytes  
ID byte 08 = internal command  
Function code 20 = stop time stamping  
Number data bytes  
Checksum  
To resume time stamping send the following command:  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
5
6
01  
02  
08  
10  
00  
1B  
Start of frame  
Number of control bytes  
ID byte 08 = internal command  
Function code 10 = resume time stamping  
Number data bytes  
Checksum  
Time stamping will resume after reset.  
10  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Master Reset Command  
The master reset command allows the HDV100A3 to be reset from the PC.  
Sending this command resets the HDV100A3 to the default start-up state.  
You will lose all setting sent in the smart mode.  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
5
6
7
8
01  
04  
08  
08  
01  
02  
00  
18  
Start of frame  
Number of control bytes  
ID byte 08 = internal command  
Function code 08= master reset  
Check byte  
Check byte  
Number data bytes  
Checksum  
Note: after sending a master reset the baud rate is 115,2k (default).  
Vendor Information  
To receive the vendor information from the HDV100A3 send hex (01, 01,  
05, 00, 07) to the device. It will respond as follows:  
Hex (01, 0B, 85, MM, DD, MA, M1, M2, MO, 00, VV, VV, 00, DB, CS)  
0B = Number of control bytes  
85 = Compatibility with other models  
MM = Month firmware was created  
DD = Day firmware was created  
MA = Major firmware revision number  
M1 = MSB of minor firmware revision  
M2 = LSB of firmware revision  
MO = Model  
VV = Customer code 1  
VV = Customer code 2  
DB = Number of data bytes  
CS = Checksum  
HDV100A3 Command & Response Manual-1306cr  
11  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J1708 Commands  
Receiving Data from the J1708 Bus  
After the HDV100A3 is set into its Intelligent mode of operation  
and the RS-232 data rate is configured, you are now ready to communicate  
with the J1708 bus. A receive command must be sent to the HDV100A3  
before attempting to transmit to the bus. The receive message synchronizes  
the HDV100A3 with the bus. To start receiving J1708 bus data, send the  
following to the HDV100A3.  
Byte  
Byte Value  
Byte Function  
Number  
(hex)  
01  
02  
01  
11  
1
2
3
4
5
6
Start of frame  
The number of control bytes  
ID byte 01= J1708  
Function code 11 hex start receive  
Number of data bytes (00 place holder)  
Checksum (bytes 1 through 5 added together)  
00  
15  
After sending this command to the device, the device will respond  
with a confirmation message. The message confirms that the command was  
received by the HDV100A3 and the checksum verified correctly. The reply  
from the device is formatted as follows:  
Byte  
Number  
Byte Value Byte Function  
(hex)  
1
2
3
4
5
01  
01  
01  
00  
03  
Start of frame byte  
Control byte  
ID byte (ID of the sent message)  
Number of data bytes  
Checksum  
The confirmation message is sent in response to a command sent to  
the device. The ID byte and the check-sum will change with different  
commands but the format will remain the same. If the checksum is not  
correct an error message is sent. Its format is covered at the end of this  
document.  
To stop receiving data from the J1708 bus send the following  
command to the HDV100A3.  
12  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Byte  
Byte value  
Byte Function  
number (hex)  
1
2
3
4
5
6
01  
02  
01  
10  
00  
14  
Start of frame  
The number of control bytes  
ID byte 01= J1708  
Function code 10 hex stop receive  
Number of data bytes (00 place holder)  
Checksum (bytes 1 through 5 added  
together)  
After sending this command to the device, the device will respond  
with a confirmation message and data will cease. Note that there is the  
possibility of an incomplete message being sent to the PC after sending this  
command. Use the check-sum to verify all messages.  
To restart reception, send the (01, 02, 01, 11, 00, 15) command to  
the HDV.  
HDV100A3 Command & Response Manual-1306cr  
13  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transmitting Data to the J1708 Bus  
The HDV100A3 supports standard J1708 commands of up to 21  
bytes. Additionally the HDV100A3 can send messages up to 100 bytes to  
the J1708 bus. It is the responsibility of the sending software to check for  
“ignition off” before using the J1708 bus to send messages with more than  
21 bytes to the bus. Failure to check for a “quiet bus” condition before  
transmitting a long message may cause erratic bus operation. The format to  
send information to the J1708 bus is shown below:  
Byte  
Byte  
Byte Function  
Number Value  
(hex)  
1
2
3
4
5
6
01  
03  
01  
12  
Start of frame  
Number of control bytes  
ID bytes 1= J1708  
Function code 12 (hex) transmit to J1708 bus  
Priority byte 00000010 set bit 0 to 7 see below  
Number of data bytes to follow (excludes checksum byte)  
Data bytes up to 100 bytes  
02  
XX  
YY  
CS  
Checksum  
Set the priority bit using the chart below.  
Priority Byte Value  
Binary Value  
00000001  
00000010  
00000100  
00001000  
00010000  
00100000  
01000000  
10000000  
Hex Value  
1
2
3
4
5
6
7
8
01  
02  
04  
08  
10  
20  
40  
80  
14  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
After sending a transmit message to the HDV100A3 you will get  
the confirmation message if the checksum is correct. A transmit complete  
message is sent to the PC after the device successfully transmits the message  
to the J1708 bus. A second message should not be sent to the device before  
confirming that the first message has been sent. The transmit confirmation is  
formatted as follows:  
Byte  
Byte Value  
Byte Function  
Number  
(hex)  
01  
01  
09  
00  
1
2
3
8
9
Start of frame  
Number of control bytes  
ID bytes 9 = transmit OK  
Number of data bytes  
Checksum  
0B  
HDV100A3 Command & Response Manual-1306cr  
15  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J1708 Message Filter  
The J1708 message filter will operate on 4 different MID’s. Only messages  
with the same MID as set in the filter will be sent to the PC. The filters will  
be OR’ed together so that multiple MID’s can be filtered, MID1 or MID2 or  
MID3. The format for the setting of J1708 filtering is as follows:  
Set Filter Active  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
5
6
7
01  
03  
01  
X9  
XX  
00  
Start of frame  
Control bytes  
ID byte 1 = J1708 message  
Set filter 9 = Set filter active X = filter number 1 to 4  
Value of MID to filter On  
Data bytes  
CS  
Checksum  
Set Filter Off  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
6
7
01  
02  
01  
X8  
00  
CS  
Start of frame  
Control bytes  
ID byte 1 = J1708 message  
Set filter 8 = Set filter inactive X = filter number 1 to 4  
Data bytes  
Checksum  
Setting all filters off will stop all data from the J1708 bus. When all filters  
are set off you must send the receive J1708 command to start receiving all  
bus messages.  
16  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Broadcast Message  
The HDV100A3 supports one broadcast message. Once configured by the  
host application, this message will be sent repeatedly by the HDV100A3 at a  
programmed time interval. This feature is useful to provide a “heartbeat”  
function to the J1708 bus with no overhead to the host application’s  
software. Sending 0 in the time value stops the broadcast message from  
being sent.  
To start a broadcast message the time interval, message slot,  
priority, number of data bytes, and the data must be sent to the HDV100A3.  
Once sent, the HDV100A3 will send the message out on the bus at the  
specified interval. Existing bus traffic or any bus messages sent to the  
HDV100A3 from the host application take priority over a pending broadcast  
message.  
Once a broadcast message is started the “Stop Broadcast 07”  
message must be sent before any changes to the broadcast message can be  
made. Changing from one time value (17) to another (37) without stopping  
the broadcast will cause the HDV100A3 to act erratically.  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
5
6
7
01  
04  
01  
X7  
0X  
PP  
YY  
Start of frame  
Control bytes  
ID byte 1 = J1708 message  
Set broadcast 7 = On X = Time interval (see chart)  
Message slot number (01 only active at this time)  
Priority (see chart below)  
Data bytes  
DATA From 4 to 21 bytes  
CS Checksum  
HDV100A3 Command & Response Manual-1306cr  
17  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To stop broadcast transmission it is not necessary to send the whole  
message. The message below will stop broadcast transmission.  
Byte  
Byte  
Function  
Number Value  
1
2
3
4
7
8
01  
02  
01  
07  
00  
0B  
Start of frame  
Control bytes  
ID byte 1 = J1708 message  
Set broadcast 7 = On X = Time interval (see chart)  
Data bytes  
Checksum  
Byte 4 Values  
Byte  
Value  
07  
Time  
Value  
Stop broadcast  
.5 sec.  
17  
27  
1.0 sec  
37  
1.5 sec  
47  
2.0 sec  
Byte 6 (Priority) Values  
Byte Value  
(hex)  
Byte Value  
Binary  
Priority  
01  
02  
04  
08  
10  
20  
40  
80  
00000001  
00000010  
00000100  
00001000  
00010000  
00100000  
01000000  
10000000  
1
2
3
4
5
6
7
8
18  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J1939 Commands  
The J1939 protocol is similar to the J1708 protocol.  
The message starts with Start of Frame byte 01. The number of  
control bytes will be 06. The control code for J1939 is 02. The function  
codes (XX) are as follows:  
00=Sets receive function off  
01=Sets receive on  
02=Transmits a message with data  
04=Set mask  
19=filter 1 set on  
18=filter 1 set off  
29=filter 2 set on  
28=filter 2 set off  
39=filter 3 set on  
38=filter 3 set off  
49=filter 4 set on  
48=filter 4 set off  
Function codes are shown in detail below.  
Before operating the HDV100A3 in the J1939 mode it is  
recommended that the baud rate be set to 115.2kb. This is done by sending  
the following code: (01, 05, 08, 01, 03, 04, 00, 00 16). After sending this  
command the baud rate of the sending device (PC) must also be changed.  
Because of the difference in baud rates between the J1939 bus and  
the RS-232 serial bus, the HDV100A3 may miss messages on the J1939 bus.  
This depends on bus load, message length, and filter settings.  
Sending any message with a control code of (02) to the J1939 bus  
stops the operation on the J1708 bus. If you wish to restart operation on the  
J1708 bus you must send the start J1708 reception message (01, 02, 01, 11,  
00, 15). Sending this message stops operation on the J1939 bus.  
Function codes 00 and 01, Receive OFF, ON operate together to control a  
receive register. Sending the command (01, 02, 02, 01, 00, 06) starts  
reception on the J1939 bus. This command resets the filter mask to all zeros  
(don’t care). All bus traffic is then received. However, it may not be possible  
to send all messages to the PC side. Any message that is not serviced before  
the next message is received will be overwritten by the new message.  
Sending the command (01, 02, 02, 00, 00, 05) turns off the receiver. It is  
HDV100A3 Command & Response Manual-1306cr  
19  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
wise to set the receiver off when not in use. Sending the Start Receive clears  
the mask. This renders the filter function useless.  
Start Receive on J1939 Bus  
Byte  
Byte  
Function  
Number  
Value  
1
2
3
4
5
6
01  
02  
02  
01  
00  
06  
Start of frame  
Control bytes  
ID byte 02 = J1939 message  
Function code 01 start reception  
Data bytes  
Checksum  
Stop Receive on J1939 Bus  
Byte  
Number  
Byte  
Value  
01  
02  
02  
00  
00  
05  
Function  
1
2
3
4
5
6
Start of frame  
Control bytes  
ID byte 02 = J1939 message  
Function code 00 stop reception  
Data bytes  
Checksum  
20  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Data messages received from the HDV100A3 operating in the J1939 mode,  
is formatted as follows:  
Control Field  
Start # of Contr Time Stamp # of Arbitration  
of Control Byte 4 Bytes Data Field  
Frame bytes Bytes  
Data Field  
# of  
Data  
Bytes  
in  
Bus Data  
Up to 8 Bytes  
Check  
sum  
Message  
lsb ZZ Y1 Y2 Y3 Y4 0X  
01  
05  
02 msb  
The message starts with 01. The number of control bytes is 05. Next is the  
control byte 02, followed by the time stamp, four bytes, with msb first. The  
number of data bytes is the number of bytes to follow excluding itself and  
the checksum byte. Next is a four byte that contains the arbitration field.  
J1939 divides this field for different functions show in the chart below. The  
number of data bytes sent by the bus is next. This will be a value between 0  
and 8. Next is the bus data followed by the checksum byte.  
Arbitration Field (Y1, Y2, Y3, Y4)  
The first byte Y1 contains the most significant bits in the J1939 arbitration  
field. It is followed by Y2, Y3 and Y4. J1939 assigns different function to  
the arbitration field that must be observed by the user. There is a work sheet  
included on page 33 to help set up this field.  
Arbitration Byte  
Arbitration Bit  
Y1  
Y2  
Y3  
Y4  
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0  
J1939 Arbitration Field 29282726252423222120191817161514131211109 8 7 6 5 4 3 2 1  
Bit Position  
J1939 Function  
Priority R D PDU Format  
bits  
PDU Specific  
Source Address  
P
HDV100A3 Command & Response Manual-1306cr  
21  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A message received from the HDV will be formatted as follows:  
<01><05><02><06><C7><CC><ED><0D><67><80><20><00><08><F0><7D><DA><00><  
00><FF><FF><DA><C9>  
The < > are placeholders and are NOT transmitted with the data.  
** = value changes with message.  
Byte  
Byte  
Function  
Number Value  
1
01  
Start of frame  
2
05  
Control bytes  
3
4
02  
06  
ID byte 02 = J1939 message  
Time stamp MSB **  
5
C7  
CC  
ED  
0D  
67  
80  
20  
00  
08  
F0  
7D  
DA  
00  
00  
FF  
FF  
DA  
C9  
Time stamp MSB –1 **  
Time stamp MSB –2 **  
Time stamp LSB **  
Number of data bytes to follow (13 dec) **  
First byte of arbitration field **  
Second byte of arbitration field **  
Third byte of arbitration field **  
Fourth byte of arbitration field **  
Number of data bytes in bus message **  
Data bytes **  
Data bytes **  
Data bytes **  
Data bytes **  
Data bytes **  
Data bytes **  
Data bytes **  
Data bytes **  
Checksum **  
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
Function code 02 sends data to the J1939 bus.  
The transmit code is set up as follows: (01, 06, 02, 02, XX, XX, XX, XX,  
DD, YY, YY, YY, YY, YY, YY, YY, YY, CS). The header starts with 01.  
There are six control bytes (06). The control code is (02). The transmit  
command is (02). The arbitration field is filled out as shown above. There is  
also a worksheet to help fill out this field. Next is the number of data bytes  
in the data payload. The data payload for the message is entered in the data  
field. After a transmission is successfully sent out and confirmed by at least  
one active node, an acknowledge message is sent to the PC  
(01, 01, 02, 00, 04). There is a form on page 33 to help set up the arbitration  
field.  
22  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transmit Data to J1939 Bus  
Byte  
Number  
Byte  
Value  
01  
06  
02  
Function  
1
2
3
4
5
6
7
8
9
Start of frame  
Control bytes  
ID byte 1 = J1708 message  
Function byte 02 transmit message  
MSB of arbitration field (J1939 priority bits)  
MSB-1  
02  
XX  
XX  
XX  
XX  
DD  
DATA  
CS  
MSB-2  
LSB of arbitration field (J1939 source address)  
Number of data bytes  
From 0 to 8 bytes  
Checksum  
Set Mask  
Function code 04 set mask. The mask is applied to ALL filters. The mask is  
32 bits long. The last 3 bits are not used and must be set to zero. This mask  
covers the 29-bit arbitration field. To use the filter function, the mask must  
be set. The mask determines what position(s) will be tested and matched to  
the incoming message. If a 1 is set in a particular position, that position will  
be tested. It will be “and” with any active filters to determine if the message  
will be passed to the PC side. Any position marked with a 0 is a “don’t care”  
position and will pass all data in that position. There is a form on page 33  
that helps set up the mask for the arbitration field.  
Byte  
Byte  
Function  
Number Value  
1
01  
Start of frame  
2
06  
Control bytes  
3
4
5
6
7
8
9
10  
02  
04  
ID byte 02 = J1939  
Function byte 04 set mask  
MSB of arbitration field (J1939 priority bits)  
MSB-1  
XX  
XX  
XX  
XX  
00  
MSB-2  
LSB of arbitration field (J1939 source address)  
Number of data bytes  
Checksum  
CS  
HDV100A3 Command & Response Manual-1306cr  
23  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The mask can be used to look at a group of messages:  
To set the mask to filter on the J1939 priority field, the mask would be  
loaded with:  
(01, 06, 02, 04, E0, 00, 00, 00, 00, ED)  
To set the mask to filter on the J1939 PGN field, the mask would be loaded  
with:  
(01, 06, 02, 04, 07, FF, F8, 00, 00, 0B)  
To set mask to filter on both the priority field and the PGN field the mask  
would be loaded with:  
(01, 06, 02, 04, B7, FF, F8, 00, 00, BB)  
Set Filter 1 to 4  
Function codes 18 and 19, 28 and 29, 38 and 39, 48 and 49 are filter pairs.  
These filters are set by sending the desired arbitration code to each filter, 1  
to 4. The filters work with the mask function. If the mask is set to zero in a  
position (don’t care) the value of the filter in that position doesn’t matter.  
The filter arbitration field is set to match the aberration code of the incoming  
message. A match of the filter “and” the mask will pass the message to the  
PC. The X9 sets the filter On; X8 sets the filter Off, where X=1 through 4.  
Important: the receiver and each filter must have a different arbitration  
code. If the receiver and a filter are given the same arbitration code the  
controller may become erratic. It will need to be powered-off reset to  
recover from this error.  
Byte  
Byte  
Function  
Number Value  
1
01  
Start of Frame  
2
06  
Control bytes  
3
02  
ID byte = J1708 message  
4
5
6
7
8
9
YY  
XX  
XX  
XX  
XX  
00  
Function byte (18 or 19) (28 or 29) (38 or 39) (48 or 49)  
MSB of arbitration field (J1939 priority bits)  
MSB-1  
MSB-2  
LSB of arbitration field (J1939 source address)  
Number of data bytes  
10  
CS  
Checksum  
To use the HDV100A3, the filter for a particular J1939 PGN the following  
procedure must be followed.  
1. Turn off the “Receive” function by sending (01, 02, 02, 00, 00, 05).  
24  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Set the “Mask” to the desired pattern (01, 06, 02, 04, XX, XX, XX, XX,  
00, CS).  
3. Set a filter (1 to 4) to the match value (01, 06, 02, YY, XX, XX, XX, XX,  
00, CS). Be sure that this is NOT the same as any other filter value or the  
HDV100A3 may become erratic.  
4. Sending this value to the HDV100A3 will continuously send this match to  
the PC.  
Note that sending the “ Start Receive” or the “Stop Receive” command  
resets the mask rendering the filters useless.  
HDV100A3 Command & Response Manual-1306cr  
25  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J1939 Header Worksheet  
This worksheet will aid in filling out/decoding the J1939 arbitration field.  
Bit  
Number  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
11  
10  
9
J1939  
Function  
Priority Bits  
CAN Frame  
Entry  
Hex  
Value  
Byte 1  
Byte 2  
Byte 3  
Byte 4  
Reserved  
Data Page  
PDU-Format  
(PGN Byte 2)  
0
0
PDU Specific  
(PGN Byte 3)  
8
7
6
5
Source Address  
4
3
2
1
0
0
0
26  
HDV100A3 Command & Response Manual-1306cr  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Error Codes  
Error Code Format:  
Byte Number  
Byte Value  
Function  
1
2
3
4
5
6
7
01  
03  
05  
XY  
0Z  
00  
Start of frame  
Number of control bytes  
Function code error = 05  
ID of message that caused error  
Error code (see chart below)  
Number of data bytes  
Checksum  
CS  
Error Code  
Type of Error Meaning of Error Generated  
Generated  
DEC HEX  
1
1
Gen  
Inbuffer overflow; more than 127 bytes  
2
2
Gen  
Checksum mismatch  
3
4
5
6
3
4
5
6
Gen  
Protocol error; function, ID, code bad  
J1708 input buffer full missed bus message  
J1708 command unknown  
J1708  
J1708  
J1708  
J1708 output buffer full  
7
7
8
9
8
9
J1939  
J1708  
Bus off  
10  
11  
12  
13  
14  
A
B
C
D
E
F
J1708 inbuffer overflow more than 127 bytes  
15  
HDV100A3 Command & Response Manual-1306cr  
27  
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ADC Network Card 410F User Manual
Adcom Stereo Amplifier GFA 555MS User Manual
AEG Refrigerator SKZ71800F0 User Manual
Agilent Technologies Stereo System 08663 90069 User Manual
Alpine Computer Drive KCA SC100 User Manual
Atmel Computer Drive AT85RFD 07 User Manual
Audiovox Automobile Alarm PRO 9600 User Manual
Audiovox Remote Starter APS 650RS User Manual
Axor Plumbing Product 9448000 User Manual
Behringer Stereo Amplifier AT108 User Manual