Avocent Network Card EVR1500 AM User Manual

EVR1500  
Installer/User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EVR1500  
Installer/User Guide  
Avocent, the Avocent logo, The Power of Being There and  
DSView are registered trademarks of Avocent Corporation.  
All other marks are the property of their respective owners.  
© 2004 Avocent Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USA Notification  
Warning: Changes or modifications to this unit not expressly approved by the party  
responsible for compliance could void the user's authority to operate the equipment.  
Note: This equipment has been tested and found to comply with the limits for a Class A  
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated in a  
commercial environment. This equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in accordance with the instruction  
manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference in which case the  
user will be required to correct the interference at his own expense.  
Canadian Notification  
Japanese Approvals  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.  
Safety and  
EMC Standards  
USA (UL, FCC)  
Canada (cUL)  
European Union (CE)  
Japan (VCCI)  
Australia (C-tick)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Chapter 1: Product Overview  
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Typical Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Chapter 2: Installation  
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Mounting the EVR1500 Environmental Monitor Appliance . . . . . . 11  
Installing the EVR1500 Environmental Monitor Appliance . . . . . . 12  
Configuring the EVR1500 Environmental Monitor Appliance . . . . 13  
Chapter 3: Basic Operations  
Launching the Web Browser GUI . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Launching Through DSView Software . . . . . . . . . . . . . . . . . . . . . . . 20  
Configuring the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Configuring the Email Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
Setting the Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
Changing the Login Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
Configuring Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
Configuring Analog Inputs and Internal Sensors . . . . . . . . . . . . . . . . 27  
Configuring Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
Configuring Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31  
Configuring XML Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33  
Configuring Delimited Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
Configuring User Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
Configuring Email Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
Configuring SNMP Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40  
Configuring FTP Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42  
Configuring Combination Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
Configuring Output Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
Configuring Report To File Actions . . . . . . . . . . . . . . . . . . . . . . . . . . 47  
Viewing Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49  
Chapter 4: Advanced Operations  
Setting Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
Configuring Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55  
Configuring Timed Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
Configuring User Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents (Continued)  
Appendices  
Appendix A: Application Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . 63  
Appendix B: Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . 65  
Appendix C: EVR1500 Environmental Monitor Appliance Pinouts . . 67  
Appendix D: SNMP Trap MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70  
Appendix E: Customer-Supplied Sensors . . . . . . . . . . . . . . . . . . . . . 72  
Appendix F: Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Overview  
1
Contents  
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Typical Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Product Overview  
3
Chapter 1: Product Overview  
Features and Benefits  
The Avocent EVR1500 environmental monitor and control appliance manages  
environmental conditions within a rack and/or data center through a standard  
web browser or the Avocent DSView® software. By combining analog and  
digital technology, the EVR1500 environmental monitor appliance collects data  
from internal and external sensors, compares it to pre-configured parameters,  
issues alarms, generates reports and acts on conditions and events. Multiple  
users can access the appliance locally or remotely.  
Access via network connection  
Users can access the EVR1500 environmental monitor appliance remotely over  
Ethernet from a web browser or a PC running DSView software. User PCs can  
be located anywhere a valid network connection exists. No special software or  
drivers are required on the attached, or host, computers. The EVR1500  
environmental monitor appliance can be configured on a separate network  
from your data network, allowing you to view and report your environmental  
conditions even if your applications network is down. This feature is important  
because loss of access to the data network could be due to adverse  
environmental or security conditions.  
Web-based GUI  
The EVR1500 environmental monitor appliance provides an easy-to-use web-  
based GUI (Graphical User Interface) that enables you to configure the  
network, digital and analog sensors, thresholds and alarm reports. The  
software is a Java™ applet uploaded from the EVR1500 environmental monitor  
appliance to a computer.  
User-configurable environmental conditions  
Environmental thresholds set through the web GUI trigger alarms that can be  
automatically reported on the application screen, emailed, sent to a pager or sent  
to an NMS (Network Management System) using SNMP (Simple Network  
Management Protocol).  
Internal and external sensors  
The EVR1500 environmental monitor appliance provides four internal sensors:  
Temperature, Humidity, Air Flow and Audio. The EVR1500 environmental  
monitor appliance also supports up to eight external analog sensors, six  
external digital sensors and two digital outputs. The external sensors enable  
you to monitor precise locations within the rack or data center. See Figure 1.1  
and the EVR1500 Environmental Monitor Appliance Features table for details.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
EVR1500 Installer/User Guide  
Internal Sensors  
Ethernet  
Connection  
Serial Port  
Analog Sensors  
Digital Sensors  
DC Power  
USB Ports  
Figure 1.1: EVR1500 Environmental Monitor Appliance Front and Back Panel  
EVR1500 Environmental Monitor Appliance Features  
Feature  
Description  
Internal Sensors  
Analog Sensors  
Digital Sensor Inputs  
Digital Sensor Outputs  
USB port 1  
Four internal sensors (Temperature, Humidity, Air Flow, Audio)  
Eight inputs (RJ-45) with 12 VDC (Volts DC) powering  
Six, plug-in modules 1 to 6  
Two, plug-in modules 7 and 8  
Reserved for future use  
USB port 2  
Reserved for future use  
Serial port  
Used for configuration  
DC power connection  
ARI port  
For power supply (provided by Avocent)  
Not in use  
KVM console  
Not in use  
Typical Configuration  
Shown in Figure 1.2, a typical configuration consists of the EVR1500  
environmental monitor appliance, a serial connection for setup, an Ethernet  
connection and a PC running Microsoft® Internet Explorer (IE) or Avocent  
DSView software.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Product Overview  
5
External Sensors  
Analog Sensors  
(up to eight)  
Digital Inputs  
(up to six)  
Digital Outputs  
(up to two)  
Internal Sensors  
• Temperature  
• Humidity  
• Air Flow  
• Audio  
Serial  
Connection  
TCP/IP  
DSView Software  
User  
TCP/IP  
Web GUI User  
Figure 1.2: Typical EVR1500 Environmental Monitor Appliance Configuration  
Safety Precautions  
To avoid potential problems when using Avocent products, use only DC power  
supplied by Avocent.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
EVR1500 Installer/User Guide  
CAUTION: The EVR1500 environmental monitor appliance contains an internal battery that is  
used for the real time clock. This battery is not a field replaceable item, and replacement should  
not be attempted by a user. If real time clock errors occur and the battery is suspected, visit the  
(888) 793-8763.  
NOTE: The AC power cord is the main disconnect.  
Rack and wall mount safety considerations  
Elevated Ambient Temperature: If installed in a closed rack assembly, the  
operation temperature of the rack environment may be greater than room  
ambient. Use care not to exceed the rated maximum ambient temperature  
of the appliance.  
Reduced Air Flow: Installation of the equipment in a rack should be such  
that the amount of airflow required for safe operation of the equipment is  
not compromised.  
Mechanical Loading: Mounting of the equipment in the rack should be such  
that a hazardous condition is not achieved due to uneven mechanical loading.  
Circuit Overloading: Consideration should be given to the connection of  
the equipment to the supply circuit and the effect that overloading of  
circuits might have on overcurrent protection and supply wiring. Consider  
equipment nameplate ratings for maximum current.  
Reliable Earthing: Reliable earthing of rack mounted equipment should be  
maintained. Pay particular attention to supply connections other than  
direct connections to the branch circuit (for example, use of power strips).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
2
Contents  
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Mounting the EVR1500 Environmental Monitor Appliance . . . . . . 11  
Installing the EVR1500 Environmental Monitor Appliance . . . . . . 12  
Configuring the EVR1500 Environmental Monitor Appliance . . . . 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
9
Chapter 2: Installation  
Getting Started  
Before installing your EVR1500 environmental monitor appliance, refer to the  
following lists to ensure that you have all the items that shipped with the  
appliance as well as other items necessary for proper installation.  
Supplied with the EVR1500 environmental  
monitor appliance  
The following items are supplied with the EVR1500 environmental  
monitor appliance:  
EVR1500 environmental monitor appliance  
One DC power supply  
One serial null modem cable (Avocent part number 042-0063)  
Wall mounting brackets and screws  
EVR1500 Installer/User Guide  
EVR1500 Quick Installation Guide  
Additional items needed  
For the mount shelf rack option, order the 1U Mount Shelf Rack kit (Avocent  
part number 790200).  
Hardware requirements  
The following hardware requirements are necessary for a PC connecting to the  
EVR1500 environmental monitor appliance:  
300 MHz processor  
128 Mb or more of DRAM (Dynamic Random Access Memory)  
Software requirements  
The following software requirements are necessary for a PC connecting to  
the EVR1500 environmental monitor appliance:  
Microsoft® Windows® 2000 Professional SP3 or Microsoft Windows XP  
Professional SP1a  
J2SE™ Runtime Environment 1.4.2 or later  
Microsoft Internet Explorer (IE) 5.5 SP2 or IE 6 SP1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
EVR1500 Installer/User Guide  
NOTE: You can download the J2SE Runtime Environment from the Sun Microsystems™ web  
site by typing http://java.sun.com/j2se/downloads.html in the web browser address bar.  
If you do not have the J2SE Runtime Environment installed on your PC when you first connect  
to the EVR1500 environmental monitor appliance with a web browser, the appliance will  
redirect your browser to the java.sun.com web site so that you can download and install the  
correct J2SE Runtime Environment files on your PC.  
CAUTION: Downloading the newest version of Java J2SE may affect other Java-accessible  
devices. If devices are affected, check them for the most recent version of code.  
Verification of Ethernet and sensor conditions  
The LEDs on the front and back panels of the EVR1500 environmental monitor  
appliance show the status of the appliance and the Ethernet connection. LEDs  
on the front panel also indicate the status of the internal sensors. Refer to the  
following table for descriptions of the LEDs on the EVR1500 environmental  
monitor appliance.  
Front Panel LEDs  
LED Label  
Color  
Description  
PWR  
Green  
When illuminated, indicates the appliance  
is powered.  
LINK  
Green  
Amber  
When illuminated, indicates an active  
connection to the network.  
10/100  
When illuminated, indicates communication at  
the 100 Mb rate. When not illuminated, indicates  
10 Mb rate.  
TEMP  
Green  
Red  
When illuminated green, temperature is normal.  
When illuminated red, temperature is  
over/under threshold.  
HUM  
Green  
Red  
When illuminated green, humidity is normal.  
When illuminated red, humidity is over/  
under threshold.  
A/F (Air Flow)  
AUDIO  
Green  
Red  
When illuminated green, air flow is normal.  
When illuminated red, air flow is  
over/under threshold.  
Green  
Red  
When illuminated green, audio is normal.  
When illuminated red, audio is over/under threshold.  
NOTE: TEMP, HUM, A/F and AUDIO LEDs are controlled by the GUI configuration for each  
specific sensor.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
11  
Back Panel LEDs  
LED Label  
Color  
Description  
CF (Compact FLASH) Amber  
Blinks to indicate activity to the Compact FLASH  
Illuminates to indicate the appliance is powered  
PWR  
LINK  
Green  
Green  
Illuminates to indicate an active connection  
to the network  
TX  
Amber  
Blinks to indicate network activity  
Mounting the EVR1500 Environmental  
Monitor Appliance  
You can wall mount your EVR1500 environmental monitor appliance using  
the supplied wall mounting kit. You also can rack mount your appliance on a  
standard shelf or the 1U Rack Mount Shelf (supplied separately: Avocent part  
number 790200) using the instructions provided with the kit. See Figure 2.1 for  
the wall mounting option.  
Figure 2.1: EVR1500 Environmental Monitor Appliance Wall Mounting Diagram  
To wall mount the environmental monitor appliance:  
1. Using the screws supplied with the wall mounting brackets, place the  
brackets on the EVR1500 environmental monitor appliance.  
2. While holding the appliance in the preferred mounting position, mark the  
holes needed for the wall plugs.  
NOTE: For proper operation of the internal sensors, mount the EVR1500 environmental  
monitor appliance with the Avocent logo in the “up” position, as shown in Figure 2.1.  
3. Install the wall plugs.  
4. Install the EVR1500 environmental monitor appliance and fasten the  
screws to hold the appliance in place.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
EVR1500 Installer/User Guide  
Installing the EVR1500 Environmental  
Monitor Appliance  
Figure 2.2 illustrates one possible configuration for your EVR1500  
environmental monitor appliance. Follow the detailed set of procedures  
following Figure 2.2 to successfully install the appliance.  
AC Power Cord  
DC Power  
Module  
Serial Port  
USB Ports  
Analog Sensors Digital Inputs/  
Outputs  
Figure 2.2: Basic EVR1500 Environmental Monitor Appliance Configuration  
WARNING: To reduce the risk of electric shock or damage to your equipment-  
- Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times.  
- Disconnect the power from the appliance by unplugging the power cord from either the  
electrical outlet or the DC power supply.  
To install the EVR1500 environmental monitor appliance:  
1. Using an Unshielded Twisted Pair (UTP) CAT 5 cable, connect the  
network port on the back of the EVR1500 environmental monitor  
appliance to your LAN.  
2. On the back of the appliance, under Analog Sensors, insert sensor cables  
supplied by Avocent or a third party into any of the RJ-45 ports. Place the  
sensor in the desired location. See Appendix C for pinout information.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
13  
3. On the back of the EVR1500 environmental monitor appliance, insert into  
plug-in modules 1 to 6, 2-wire digital sensors supplied by Avocent or a  
third party. Place the sensor in the desired location. See Appendix C for  
pinout information.  
NOTE: Plug-in modules 7 and 8 are digital output ports.  
4. With the small white ridge of the power connector facing up, plug the  
supplied power cord into the back of the EVR1500 environmental monitor  
appliance. Connect the appliance by plugging one end of the AC power  
cord into the switching power supply. Plug the other end of the power  
cord into the appropriate AC power source.  
5. When power is applied, the appliance performs a boot sequence for  
approximately 60 seconds. After the boot sequence is complete, press the  
Enter key to display the login prompt on the Terminal screen. To manually  
set the IP address follow the instructions in the next section, Configuring  
the EVR1500 Environmental Monitor Appliance.  
NOTE: The EVR1500 environmental monitor appliance is factory configured to use the DHCP  
(Dynamic Host Configuration Protocol) to obtain an IP address from the network. If your  
appliance does not have a MAC address on the bottom of the appliance, you can obtain a MAC  
address from the CLI (Command Line Interface) using the ifconfig command as shown  
in Figure 2.3.  
6. Using Internet Explorer, launch the web GUI by typing the IP address  
configured in the Configuring the EVR1500 Environmental Monitor  
Appliance section.  
NOTE: You can download this application from the Sun Microsystems web site by typing  
http://java.sun.com/j2se/downloads.html in the web browser address bar.  
Once the IP address has been set through the Terminal screen, changes to the IP address can  
be made through the web GUI. Refer to Configuring the Network in Chapter 3 for instructions.  
7. Finally, configure the sensors. Refer to Chapter 3 for instructions on  
configuring the sensors.  
Configuring the EVR1500 Environmental  
Monitor Appliance  
The initial configuration of the EVR1500 environmental monitor appliance  
must be performed using terminal emulation software (such as  
HyperTerminal®). After the initial configuration, you can make changes  
through a terminal connection or through the web GUI. See Configuring the  
Network in Chapter 3 for instructions on configuring the EVR1500  
environmental monitor appliance through the web GUI.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
EVR1500 Installer/User Guide  
To use a terminal or terminal emulation program:  
1. After mounting the appliance, connect a terminal or PC running terminal  
emulation software to the serial port on the back panel of the EVR1500  
environmental monitor appliance using the supplied null modem cable.  
Configure your terminal or terminal emulation program as follows:  
Baud rate  
Bits per character  
Parity  
38.4K  
8 bits  
None  
Stop bits  
Flow control  
1 stop bit  
None  
2. On the Terminal screen, enter root as the default username and root as  
the default password.  
3. Verify the current IP address by entering ifconfig. As shown in Figure 2.3,  
the following default IP parameters display:  
[IP ADDRESS] [NETMASK] [GATEWAY]  
Figure 2.3: IP Parameter Summary  
4. If you wish to change the IP address, enter setip on the Terminal screen.  
The following setup options display, as shown in Figure 2.4:  
setip DHCP  
setip IP ipaddress netmask [gateway]  
NOTE: Using DHCP enables you to obtain IP address and network configuration. Gateway is  
in brackets on the screen because it is optional.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
15  
Figure 2.4: IP Parameter Setup  
5. Obtain the IP address through DHCP by entering setip DHCP.  
- or -  
Enter static IP parameters, using the following as an example:  
setip IP 192.168.1.53 (space) 255.255.255.0 (space) 192.168.1.1  
NOTE: For the DHCP server reservation, locate the MAC address on the bottom of the  
EVR1500 environmental monitor appliance or on the IP Parameter Summary window displayed  
as HWaddr in Figure 2.3.  
6. Reboot the EVR1500 environmental monitor appliance by entering reboot  
on the Terminal screen.  
7. After you have rebooted the appliance, at the login prompt, enter root as  
the username and root as the password.  
8. Verify the new IP parameters by entering ifconfig. The IP parameters are  
displayed as shown in Figure 2.3.  
9. Log out of the Terminal screen by entering logout.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
EVR Installer/User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Basic Operations  
3
Contents  
Launching the Web Browser GUI . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Launching Through DSView Software . . . . . . . . . . . . . . . . . . . . . . . 20  
Configuring the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Configuring the Email Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
Setting the Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
Changing the Login Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
Configuring Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
Configuring Analog Inputs and Internal Sensors . . . . . . . . . . . . . . . . . . .27  
Configuring Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
Configuring Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31  
Configuring XML Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33  
Configuring Delimited Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
Configuring User Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
Configuring Email Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
Configuring SNMP Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40  
Configuring FTP Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42  
Configuring Combination Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
Configuring Output Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
Configuring Report To File Actions . . . . . . . . . . . . . . . . . . . . . . . . . . 47  
Viewing Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
19  
Chapter 3: Basic Operations  
The operating platform for the EVR1500 environmental monitor appliance  
uses the Linux® 2.4 kernel and is configured through a web browser  
application. The web application requires the Java J2SE Runtime Environment  
(1.4.2 or later) for system configuration, application setup and data  
presentation. The Java applet is installed on your PC from the EVR1500  
environmental monitor appliance when you type the appropriate URL in the  
web browser address field.  
Launching the Web Browser GUI  
After you have installed the EVR1500 environmental monitor appliance, you  
are ready to launch the web application’s GUI. The web GUI provides you with  
easy-to-navigate screens for configuring the network, sensor inputs /outputs  
(I/O) and actions (such as email) that will perform alarm reporting.  
To launch the web GUI:  
1. If the J2SE Runtime Environment (1.4.2 or later) is not running on your  
computer, load the applet from the Sun Microsystems web site by typing  
the following URL in the web browser address bar:  
2. From the Sun Microsystems web page, download the J2SE Runtime  
Environment (1.4.2 or later). Once the file is downloaded, install it on your  
computer and reboot.  
3. Launch Internet Explorer and type the appropriate URL in the web  
browser address field. (For example, if your EVR1500 environmental  
monitor appliance has the IP address 192.168.1.53, type http://192.168.1.53  
in the web browser address field.) This action loads the Java applet. The  
Login window displays.  
Figure 3.1: Login Window  
4. Type admin in the User Name field.  
5. Type password in the Password field. Click OK.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
EVR1500 Installer/User Guide  
NOTE: A password can be changed by selecting the User or System tab from the web GUI  
and typing a new password in the Password field.  
6. The Main tab window displays a summary of all enabled digital and  
analog I/Os in addition to calculation values. This window also displays  
general system information.  
Figure 3.2: Main Tab  
Launching Through DSView Software  
You can launch the EVR1500 environmental monitor appliance through the  
Avocent DSView software if you are running the application on your system  
and the EVR1500 environmental monitor appliance has been added through  
the DSAdmin management application. For more information on adding and  
viewing the EVR1500 environmental monitor appliance through the DSView  
software (2.1 or later), refer to the DSView Installer/User Guide.  
To launch through DSView software:  
1. Add the EVR1500 environmental monitor appliance using the DSAdmin  
management application.  
2. Launch the DSView software. The DSView software window displays.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
21  
Figure 3.3: DSView Software Window  
3. Double-click the Topology icon. The EVR1500 environmental monitor  
appliance icon displays.  
4. Double-click the EVR1500 environmental monitor appliance icon. Internet  
Explorer is launched and the Login window displays. This action loads  
the Java applet.  
Figure 3.4: Login Window  
5. Type admin in the User Name field.  
6. Type password in the Password field. Click OK.  
Configuring the Network  
You can configure the network and set parameters for the SMTP (Simple Mail  
Transfer Protocol) email server through the web GUI Network tab. If you have  
already configured your network through HyperTerminal, the values will be  
automatically populated; you can bypass the following steps provided and  
proceed to Configuring the Email Server.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
EVR1500 Installer/User Guide  
To configure the network:  
1. After launching the web GUI, click Network - Fixed Network. The Fixed  
Network Preferences window displays a list of configuration items for the  
Ethernet. Your IP address and network settings will display. If you have an  
IP address assigned by DHCP, only the IP address will display.  
Figure 3.5: Fixed Network Preferences Window  
2. Set the EVR1500 environmental monitor appliance for DHCP operation by  
selecting the Automatic (DHCP) button. Proceed to step 4 to obtain a  
DHCP address by saving the configuration and resetting the appliance.  
- or -  
Set the EVR1500 environmental monitor appliance for manual operation  
by selecting the Manual button. If you have used HyperTerminal to  
configure the network, the Manual button is selected, and the IP Address,  
Subnet Mask and Default Gateway fields will display appropriate values. If  
desired, change the values in the fields. Proceed to step 3.  
3. Type the primary and secondary DNS IP address in the Primary and  
Secondary fields respectively.  
4. Click the Save button to save the configuration.  
- or -  
Click the Cancel button to revert all configuration items in the Network tab  
to the last Save operation.  
5. Reboot the EVR1500 environmental monitor appliance by selecting  
System - Application Update. Click Restart.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
23  
Configuring the Email Server  
You can set parameters for the SMTP email server address through the web  
GUI Network tab.  
NOTE: Configuring the email server is necessary only if you wish to send alert notifications  
through email. If you do not intend to use email alerts, you may skip the following instructions.  
To configure the email server address:  
1. After launching the web GUI, click Network - Email Preferences. The Email  
Preferences window displays the configuration items for setting  
email preferences.  
2. Type the URL or the IP address for the email server in the SMTP  
Server field.  
Figure 3.6: Email Preferences Window  
(192.168.1.1). Consult your email administrator for appropriate values for these fields.  
3. In the Server Port field, type the number of the email port on the  
SMTP Server.  
4. In the From Address field, type the email address that will be used in the  
From address in the email actions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
EVR1500 Installer/User Guide  
5. Click the Save button to save the settings for your email configuration.  
- or -  
Click the Cancel button to revert all configuration items in the Network tab  
to the last Save operation.  
Setting the Clock  
After configuring the network and/or the email server, set the network  
system time.  
To set the clock:  
NOTE: The time zone shown on the terminal emulation screen is in Greenwich Mean Time  
(GMT). The web GUI is set to the Windows time and date settings.  
1. After launching the web GUI, click System - Set Clock. A window displays  
configurable items for the clock.  
Figure 3.7: Set Clock Window  
2. Type the current time in the Hours, Minutes and Seconds fields. For the  
Hours entry, type a value from Ø to 23. Type the current date in the Month,  
Day and Year fields. For the Year entry, type a value greater than 2000.  
NOTE: Message boxes will display if values are out of range.  
3. Click Set to save the clock settings.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
25  
4. Click Refresh to update the display.  
5. Click Restart to ensure correct configuration on the EVR1500  
environmental monitor appliance.  
Changing the Login Password  
Using the Change Password feature, you can change your login password  
multiple times during your web session.  
Figure 3.8: Change Password Window  
To change your password:  
1. After launching the web GUI, click User - Change Password. A window  
displays editable fields for changing your password.  
2. Type your old password in the Old Password field.  
3. Type your new password in the New Password field.  
4. Retype your new password in the Retype New Password field.  
5. Click Set to save the new password.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
EVR1500 Installer/User Guide  
Configuring Digital Inputs  
After installing the EVR1500 environmental monitor appliance and configuring  
the network, you can view digital sensor channels and values for each digital  
input in the system. From the Digital Inputs window, you can also rename  
digital inputs.  
To configure digital inputs:  
1. After launching the web GUI, click Configuration - Digital Inputs. The  
Digital Inputs window displays the list of the system’s digital inputs.  
NOTE: The Channel column is fixed and is the internal representation of the input.  
2. Click the row containing the digital sensor input you wish to configure.  
The sensor input information displays in the dialog box.  
Figure 3.9: Digital Inputs Window  
NOTE: In Figure 3.9, the last two digits in the sensor’s default name represent the port  
connecting the sensor to the EVR1500 environmental monitor appliance. It is good practice to  
use this format when naming sensors.  
3. Click the Enabled checkbox to enable the selected digital input.  
NOTE: An enabled digital input will display in the Main tab window and will be available for use  
in the following operations: Calculations, SNMP actions, Output actions, Thresholds, Rules,  
Timed Rules and Reports.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
27  
4. If desired, edit the existing name of the digital input by clicking in the  
Unique name field and typing a new name. The name cannot contain any  
spaces. The only special character allowed is the underscore (_).  
5. If desired, set the threshold for the digital input by clicking Application -  
Thresholds. For instructions, refer to Setting Thresholds in Chapter 4.  
6. Click Save to save the changes made to the digital input(s).  
- or -  
Click Cancel to cancel the updates. Canceling displays the last saved value  
for the digital input in the Current Value cell for the entire tab.  
Configuring Analog Inputs and Internal Sensors  
After installing the EVR1500 environmental monitor appliance and configuring  
the network, you can configure, rename and test analog inputs and internal  
sensors through the Configuration tab window. Before configuring analog  
input sensors, be sure you have the necessary information, including input  
voltage range and convert value range. Typically, each analog sensor is  
shipped with the sensor’s input voltage range and a conversion table showing  
the actual values interpreted from the voltages. For example, a temperature  
sensor might have a voltage range of Ø to 5 volts with a conversion range of 5  
degrees F (Farenheit) to 140 degrees F.  
To configure analog inputs and internal sensors:  
1. After launching the web GUI, click Configuration - Analog Inputs. The  
Analog Inputs table lists eight inputs, corresponding to the eight RJ-45  
connectors on the back of the appliance. Also displayed are the four  
internal sensors (Temperature, Humidity, Air Flow and Audio) at the  
bottom of the table.  
2. Click the row containing the analog input you wish to configure. The  
analog input information displays in the dialog box.  
NOTE: In Figure 3.10, the last two digits in the sensor’s default name represent the port  
connecting the sensor. It is good practice to use this format when naming sensors.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
EVR1500 Installer/User Guide  
Figure 3.10: Analog Inputs Window  
3. Click the Enabled checkbox to enable the analog sensor input.  
NOTE: An enabled analog input will display in the Main tab window and will be available for use  
in the following operations: Calculations, SNMP actions, Output actions, Thresholds, Rules,  
Timed Rules and Reports.  
4. If desired, edit the name of the analog input by typing a new name in the  
Unique name field. The name cannot contain any spaces. The only special  
character allowed is the underscore (_).  
5. Type the minimum voltage input range (for example, Ø, 1 or 2 volts) in the  
Raw minimum value field. This range is the minimum DC voltage range  
output from the sensor.  
6. Type the maximum voltage input range (for example, 5 or 10 volts) in the  
Raw maximum value field. This value is the maximum DC voltage range  
output from the sensor.  
7. Type the analog input’s converted minimum value (for example, -40  
degrees F) in the Converted minimum value field.  
8. Type the analog input’s converted maximum value (for example, 85  
degrees F) in the Converted maximum value field.  
NOTE: Values for steps 5 to 8 are provided with the analog sensor documentation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
29  
NOTE: The two fields, Converted minimum value and Converted maximum value, enable you  
to input a conversion range used to mathematically convert an input value from its input range  
to the conversion range. The EVR1500 environmental monitor provides linear conversion  
between these values. For example, for a temperature probe with a range of Ø to 5 VDC and  
a conversion range of -40 to 85 degrees C (Celsius), 1 VDC would be equal to -40 degrees C  
and 5 VDC would be equal to +85 degrees C.  
9. In the Units for converted value field, type the unit you wish to display  
with the value (for example, degrees F or degrees C).  
10. Click Save to save the changes made to the analog input(s) and all other  
items in the Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
Configuring Digital Outputs  
After installing the EVR1500 environmental monitor appliance and configuring  
the network, you can configure and rename two digital outputs (plug-in  
modules 7 and 8) through the Configuration tab interface.  
The front panel LEDs (Audio_LED, Air_Flow_LED, Humidity_LED,  
Temperature_LED) also display in the Digital Outputs window and are  
defaulted to green [Current Value = 1 (green) or Ø (red)]. Refer to Setting  
Thresholds and Configuring Rules in Chapter 4 for instructions on configuring  
the front panel LEDs.  
NOTE: The Heater_Control digital output is used to eliminate excessive condensation from the  
internal humidity sensor. The default value is Ø or Off. Setting the value to 1 or On for 30 to 60  
seconds eliminates condensation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30  
EVR1500 Installer/User Guide  
Figure 3.11: Digital Outputs Window  
To configure digital outputs:  
1. After launching the web GUI, click Configuration - Digital Outputs. The  
Digital Outputs window displays a list of the digital sensor outputs.  
NOTE: The Channel column is not editable and is the internal representation of the input.  
2. Click the row containing the digital sensor you wish to configure or test.  
The sensor output information displays in the dialog box.  
3. Click the Enabled checkbox to enable the digital output.  
NOTE: An enabled digital output will be displayed on the Main tab. Enabling a digital output  
also makes it available for use in the following operations: Calculations, SNMP actions, Output  
actions, Thresholds, Rules, Timed Rules and Reports.  
4. If desired, edit the name of the digital output by clicking in the Unique  
name field and typing a new name. The name cannot contain any spaces.  
The only special character allowed is the underscore (_).  
5. Click the Test Selected button. The Output Value box displays, enabling you  
to set the digital output.  
6. Type a value that will be applied to the output channel. Click OK. This value  
will become the digital output’s button label. Valid settings are 1 (1 = on) or  
Ø (Ø = off).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
31  
NOTE: Clicking the Test Selected button does not save the new value.  
7. Click the Save button to save changes to the digital output(s) and all other  
items in the Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
Configuring Calculations  
The Calculations feature enables you to configure an equation and the units  
used to calculate digital and analog I/O. This feature also enables you to create  
new calculations or delete existing calculations.  
Figure 3.12: Calculations Window  
To configure calculations:  
1. After launching the web GUI, click Configuration - Calculations. The  
Calculations window displays.  
2. Edit an existing calculation by clicking the row containing the calculation.  
-or -  
Click the Create New button to add a calculation. A new row is added to  
the Calculations list.  
The calculation information displays in the dialog box.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32  
EVR1500 Installer/User Guide  
3. Click the Enabled checkbox to enable the calculation.  
NOTE: An enabled calculation is available for use in the following operations: SNMP actions,  
Output actions, Thresholds, Rules, Timed Rules and Reports.  
4. Type a unique name for the calculation in the Unique name field. The  
name cannot contain any spaces. The only special character allowed is  
the underscore (_).  
5. Type the equation for the calculation in the Calculation field using the  
format shown in the following example:  
Temp_average=($temp1+$temp2+$temp3)/3  
NOTE: Use numbers, arithmetic operators, logic operators and named items from the  
application. Named items are digital inputs, digital outputs, analog inputs and other  
calculations as shown in Figure 3.12. These items are referenced using their name (for  
example, $temp1) and are preceded with a dollar sign. For example, if analog input Ø is named  
ana_inØØ in the Analog Input configuration, it can be referenced in an equation as $ana_inØØ.  
6. Type the units for the calculation in the Display units field.  
NOTE: The field, Display units, requires a string value that is displayed with the result of the  
equation. It is not interpreted or used to affect the value. For example, in Figure 3.12, the  
Current Value field contains the display unit Deg C, also shown in the Display unit field.  
If appropriate values are not entered, a message box displays a list of available  
operands. The EVR1500 environmental monitor appliance uses standard C  
programming language operators and functions. Refer to the following table  
for the allowed operators and functions.  
Language Operators and Functions  
Operators  
Arithmetic  
Compare  
Logical  
Description  
+, -, *, /  
==, !=, ,=, <, >=. >  
&& , ||  
Functions  
abs, acos, asin, atan, ceil, cos, exp, floor, log, round,  
sin, sqrt, tan, atan2, max, min, pow, random, counter  
7. After typing the calculation equation and units, click the Test Selected  
button to perform the calculation. This button must be clicked to refresh  
the value.  
8. A message box displays the new calculation. Click OK to exit the  
message box.  
NOTE: Clicking the Test Selected button does not save the configuration change.  
9. Click the Save button to save all of the items in the Configuration tab.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
33  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete a calculation:  
1. After launching the web GUI, click Configuration - Calculations. The  
Calculations window displays a list of configured calculations.  
2. Click the row containing the calculation you want to delete.  
3. Click the Delete Selected button.  
4. Click the Save button to save the change.  
Configuring XML Reports  
The EVR1500 environmental monitor appliance enables you to generate and  
send XML reports as email or through FTP. XML reports display sensor I/O  
values encapsulated in XML format and can be attached directly to an email.  
Before sending an XML report through FTP, you must write the data to a file  
using the Report to File action. Using the XML Reports feature, you also can  
edit, test and delete existing reports.  
Figure 3.13: XML Reports Window  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34  
EVR1500 Installer/User Guide  
To configure an XML report:  
1. After launching the web GUI, click Configuration - XML Reports. The XML  
Reports window displays XML reports configured in the system. A list of  
named sensor values that you can include in an XML report also displays.  
NOTE: Enabled reports will display in drop-down menu selections and will be available for use  
in the following operations: Report to File and Email actions.  
2. Click the name of the XML report you want to edit.  
- or -  
Click the Create New button to create a new report. A new row is added to  
the XML Reports table.  
The XML report information displays in the dialog box.  
3. Click the Enabled checkbox to enable the XML report.  
4. Type a new name for the report in the Unique name field. The name  
cannot contain any spaces. The only special character allowed is  
the underscore (_).  
5. Type header information for the XML report in the Header field.  
6. In the Values table, click the checkboxes to enable the sensor values you  
wish to include in the XML report.  
NOTE: Click Check All or Clear All to select or deselect all sensor values for the report.  
7. Click the Test Selected button to test the report. A message box displays to  
show the contents of the report you are testing. Click OK to exit the  
message box.  
NOTE: Clicking the Test Selected button does not save the configuration change.  
8. Click Save to save all of the configuration items in the Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete an XML report:  
1. After launching the web GUI, click Configuration - XML Reports. The  
XML Reports window displays the XML reports configured in the system.  
2. Click the row containing the XML report you wish to delete.  
3. Click the Delete Selected button to delete the report.  
4. Click Save to save the change.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
35  
Configuring Delimited Reports  
The EVR1500 environmental monitor appliance enables you to generate and  
send delimited reports as email or through FTP. Delimited reports contain  
user-defined delimiters that separate sensor data and can be written to  
spreadsheets or other documents. Before sending a delimited report through  
FTP, you must write the data to a file using the Report to File action. Using the  
Delimited Reports feature, you also can edit, test and delete existing  
delimited reports.  
Figure 3.14: Delimited Reports  
To configure a delimited report:  
1. After launching the web GUI, click Configuration - Delimited Reports. The  
Delimited Reports window displays a list of configured delimited reports  
and a list of sensor values that you can include in a delimited report.  
NOTE: Enabled reports will display in drop-down menu selections and will be available for use  
in Report to File and Email actions.  
2. Click the name of the delimited report you want to edit.  
- or -  
Click the Create New button to add a new report. A new row is added to  
the Delimited Reports table.  
The delimited report information displays in the dialog box.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
36  
EVR1500 Installer/User Guide  
3. Click the Enabled checkbox to enable the delimited report.  
4. Type a new name for the report in the Unique name field. The name  
cannot contain any spaces. The only special character allowed is  
the underscore (_).  
5. Type a delimiter in the Delimiter field. Any delimiter, including colon (:),  
semicolon (;), comma (,), plus (+), equals (=) and minus (-), may be used.  
6. Type header information for the delimited report in the Header field. The  
values available for inclusion in the report display in the Values table.  
7. Under Selected, click the checkboxes to select sensor values you wish to  
include in the report.  
NOTE: Click Check All or Clear All to select or deselect all sensor values for the report.  
8. Click the Test Selected button to test the report. A message box displays to  
show the contents of the report you are testing. Click OK to exit the  
message box.  
NOTE: Clicking the Test Selected button does not save the configuration change.  
9. Click Save to save all of the configuration changes in the Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete a delimited report:  
1. After launching the web GUI, click Configuration - Delimited Reports. The  
Delimited Reports window displays a list of configured delimited reports.  
2. Click the row containing the delimited report you wish to delete.  
3. Click the Delete button to delete the report.  
4. Click the Save button to save the change.  
Configuring User Reports  
Using the EVR1500 environmental monitor appliance, you can generate and  
send user reports as email or through FTP. User reports can be configured as  
“free form” reports to meet your specific requirements and can be attached  
directly to an email. Before sending a user report through FTP, you must write  
the data to a file using the Report to File action. Using the User Reports feature,  
you also can edit, test and delete existing user reports.  
To configure a user report:  
1. After launching the web GUI, click Configuration - User Reports. The User  
Reports window displays the user reports configured in the system.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
37  
Figure 3.15: User Reports Window  
2. Click the name of the user report you want to edit.  
- or -  
Click the Create New button to add a new user report. A new row is added  
to the User Reports table.  
The user report information displays in the dialog box.  
3. Click the Enabled checkbox to enable the user report.  
4. Type a new name for the user report in the Unique name field. The name  
cannot contain any spaces and the only special character allowed is the  
underscore (_).  
5. Type information for the user report you wish to create in the User Report  
Script field. Make sure that you type values that are enabled and valid.  
Precede each value with a dollar sign ($), for example, $Analog_Input1.  
NOTE: The User Report Script is a free-form field. The text typed into the User Report Script  
fi e ld w ill be inserted into the user report exactly as you type it.  
6. Click the Test Selected button to test the report. A message box displays the  
contents of the report you are testing. Click OK to exit the message box.  
See Figure 3.16 for an example of a user report.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
38  
EVR1500 Installer/User Guide  
Figure 3.16: User Report  
NOTE: Clicking the Test Selected button does not save the configuration change.  
7. Click the Save button to save the changes in the Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete a user report:  
1. After launching the web GUI, click Configuration - User Reports. The User  
Reports window displays a list of configured user reports.  
2. Click the row containing the user report you wish to delete.  
3. Click the Delete Selected button to delete the report.  
4. Click the Save button to save the change.  
Configuring Email Actions  
After you have created a report, you can configure an email action to send  
your report through email. The report will be displayed as the body of the  
email. Using the Email feature, you also can edit, test and delete an existing  
email action. You can configure up to 25 email actions.  
NOTE: You must configure your email preferences before you can use the Email feature. Refer  
to Configuring the Email Server in this chapter for instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
39  
To configure an email action:  
1. After launching the web GUI, click Configuration - Email. The Email  
window displays a list of existing email actions configured in the system.  
Figure 3.17: Email Window  
2. Click the row displaying the email action you want to edit.  
- or -  
Click the Create New button to add a new email action. A new row is  
added to the Email table.  
The email action information displays in the dialog box.  
3. Click the Enabled checkbox to enable the email action.  
NOTE: An enabled email action is available for use in the following operations: Combination  
actions, Thresholds, Rules and Timed Rules.  
4. Type a new name for the email action in the Unique name field. The name  
cannot contain any spaces, and the only special character allowed is  
the underscore (_).  
5. Type the recipient’s email address in the Address to send to field. Only one  
email address is allowed per entry.  
6. Type the subject of the email message in the Subject of the message field.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
40  
EVR1500 Installer/User Guide  
7. If you wish to include a report as an attachment to the email message,  
select the report from the drop-down menu labeled Report to include.  
Selecting a report is optional.  
NOTE: The reports displaying in the drop-down menu are enabled XML, delimited and  
user reports. The selected report is used as the body of the email when it is sent.  
8. Click the Test Selected button to process the report, if applicable, and  
send the email with the selected report. Once the action is completed,  
a message box displays the status of the email being sent and any  
issues related to the report.  
NOTE: The SMTP server is used to send the email. The From email address is configured  
by selecting Network - Email.  
9. Click the Save button to save all configuration changes in the  
Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete an email action:  
1. After launching the web GUI, click Configuration - Email. The Email  
window displays a list of existing email actions configured in the system.  
2. Click the row containing the email action you want to delete.  
3. Click the Delete Selected button to delete the email action in the  
selected row.  
4. Click the Save button to save the change.  
Configuring SNMP Traps  
The SNMP Traps feature monitors and reports alarm conditions on internal  
or external sensors. You can enable pre-configured traps or develop new  
trap definitions, which the system uses as actions. Using the SNMP Traps  
feature, you can also edit, test and delete existing traps.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
41  
To configure an SNMP trap:  
1. After launching the web GUI, click Configuration - SNMP Traps. The  
SNMP Traps window displays a list of pre-configured traps.  
Figure 3.18: SNMP Traps Window  
2. Click the name of the trap you wish to edit.  
- or -  
Click the Create New button to add a new trap. A new row is added to the  
SNMP Traps table.  
The trap information displays in the dialog box.  
3. Click the Enabled checkbox to enable the trap.  
NOTE: An enabled SNMP trap is available for use in the following operations: Combination  
actions, Thresholds, Rules and Timed Rules.  
4. Type a new name for the trap in the Unique name field. The name cannot  
contain any spaces, and the only special character allowed is  
the underscore (_).  
5. Type the address of the Network Management System (NMS) or the trap  
collection system in the Manager host or IP (trap collection) field. The  
EVR1500 environmental monitor appliance will send the traps to  
these locations.  
6. Type a port number for the NMS or trap collection system in the Port on  
the manager field.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
42  
EVR1500 Installer/User Guide  
7. For a new trap, type a unique OID (Object Identifier) in the OID field. If  
the trap is notifying of a high threshold, use the following OID:  
1.3.6.1.4.1.10418.5.1.1.9  
- or -  
If the trap is notifying a low threshold, use the following OID:  
1.3.6.11.5.1.10418.5.1.1.10  
NOTE: These values conform to the EVR1500 environmental monitor appliance Trap  
MIB (Management Information Base) described in Appendix D. You may also visit  
The OIDs for pre-configured traps will display in the drop-down menu  
when you select the trap from the SNMP Traps list.  
8. Select a value from the Value to report drop-down menu. The drop-down  
menu displays all applicable enabled items.  
NOTE: The value to report can be an internal sensor, analog input, digital input or calculation  
that is reported in the trap to the NMS or trap collector.  
9. Click the Test Selected button to test the trap. A message box displays the  
status of the trap you are testing. Click OK to exit the message box.  
NOTE: Clicking the Test Selected button does not save the configuration change.  
10. Click the Save button to save the configuration items in the  
Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete an SNMP trap:  
1. After launching the web GUI, click Configuration - SNMP Traps. The  
SNMP Traps window displays a list of configured traps.  
2. Click the row containing the trap you wish to delete.  
3. Click the Delete Selected button to delete the trap.  
4. Click the Save button to save the change.  
Configuring FTP Actions  
After you have created a report and converted it to a file using the Report to  
File action, you can configure FTP actions to send your file through FTP. Using  
the FTP feature, you also can edit, test and delete an existing FTP action. You  
can configure up to 25 FTP actions. For details on the Report to File action,  
refer to Configuring Report to File Actions in this chapter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
43  
To configure an FTP action:  
1. After launching the web GUI, click Configuration - FTP. The FTP window  
displays a list of existing FTP actions configured in the system.  
Figure 3.19: FTP Window  
2. Click the row containing the FTP action you wish to edit.  
-or-  
Click the Create New button to add a new FTP action. A new row is added  
to the FTP table.  
The FTP information displays in the dialog box.  
3. Click Enabled to enable the FTP action.  
NOTE: An enabled FTP action is available for use in the following operations: Combination  
actions, Thresholds, Rules and Timed Rules.  
4. Type a new name for the FTP action in the Unique name field. The name  
cannot contain any spaces, and the only special character allowed is  
the underscore (_).  
5. Select a file from the File to Send drop-down menu. The file you select will  
be sent to the server by the FTP action. After the file is sent, the FTP action  
deletes the file.  
NOTE: Unsuccessful FTP actions do not delete files.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
44  
EVR1500 Installer/User Guide  
6. In the Host name or IP field, type the FTP server or IP address (or name  
resolvable through DNS) to which the FTP action will send its file.  
7. Type a new username in the User name field.  
8. Type the username used to log in to the FTP server in the Password field.  
The password will be displayed with asterisks (*).  
NOTE: The File to send field lists files defined by the Report to File action.  
9. Click the Test Selected button to process the FTP action. Once the action is  
completed, a message box displays the results of the action. Click OK to  
exit the message box.  
10. Click the Save button to save all configuration changes in the  
Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete an FTP action:  
1. After launching the web GUI, click Configuration - FTP. The FTP window  
displays a list of FTP actions.  
2. Click the row containing the FTP action you want to delete.  
3. Click the Delete Selected button to delete the FTP action in the  
selected row.  
4. Click the Save button to save the change.  
Configuring Combination Actions  
Using combination actions, you can combine up to four actions and then select  
the order in which the actions, including Email, SNMP Traps, FTP, Output and  
Reports, are executed. For instance, you could email a service technician, send  
an SNMP trap and then run and convert a report into a file, all in a single  
combination action. Using the Combination feature, you also can edit, test and  
delete existing combination actions. The system handles up to 25  
combination actions.  
To configure combination actions:  
1. After launching the web GUI, click Configuration - Combination. The  
Combination window displays a list of existing combination actions  
configured in the system.  
2. Edit an existing combination action by clicking the row containing the  
combination action you wish to edit.  
-or-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
45  
Click the Create New button to add a new combination action. A new row  
displays in the combination list.  
The combination action information displays in the dialog box.  
3. Click Enabled to enable the Combination action.  
Figure 3.20: Combination Window  
NOTE: An enabled combination action is available for use in the following operations:  
Thresholds, Rules and Timed Rules.  
4. Type a unique name for the combination action in the Unique name field.  
The name cannot contain any spaces. The only special character allowed  
is the underscore (_).  
5. Select actions from the drop-down menus. If the combination action is  
enabled, you must select at least two actions.  
NOTE: Actions 1 to 4 are lists of selectable Email, SNMP Traps, FTP, Output and Report to  
File actions that have been defined in the system. When a combination action is executed, the  
actions are executed in sequential order. You do not have to type an action in all four fields.  
Blank actions, indicated by dashes (-), are not processed by the system.  
6. After selecting actions, click the Test Selected button to execute the  
combination action. A message box displays with the results of each action.  
Click OK to exit the message box.  
7. Click the Save button to save all items in the Configuration tab.  
- or -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46  
EVR1500 Installer/User Guide  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete a combination action:  
1. After launching the web GUI, click Configuration - Combination. The  
Combination window displays a list of combination actions.  
2. Click the row containing the combination action you wish to delete.  
3. Click the Delete Selected button to delete the combination action.  
4. Click the Save button to save the change.  
Configuring Output Actions  
Using the Output actions feature, you can configure output actions from the list  
of digital and analog I/O in the system. The system handles up to 25  
output actions.  
Figure 3.21: Output Window  
To configure output actions:  
1. After launching the web GUI, click Configuration - Output. The Output  
window displays.  
2. Click the row containing the output action you wish to edit. A new row is  
added to the Output table.  
-or-  
Add a new output action by clicking the Create New button.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
47  
The output action information displays in the dialog box.  
3. Click Enabled to enable the output action.  
NOTE: An enabled output action is available for use in the following operations: Combination  
actions, Thresholds, Rules and Timed Rules.  
4. Type a unique name for the output action in the Unique name field. The  
name cannot contain any spaces. The only special character allowed is  
the underscore (_).  
5. Select an input value from the Input value drop-down menu.  
6. Select an output value from the Output to set drop-down menu.  
NOTE: The Input value drop-down menu contains named items representing values. When the  
output action is executed, the values from the selected item in the Input list are applied to the  
values of the item selected from the Output list.  
7. After selecting input and output items, click the Test Selected button to  
execute the output action. A message box displays with the results of  
the action.  
8. Click the Save button to save all items in the Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete an output action:  
1. After launching the web GUI, click Configuration - Output. The Output  
window displays a list of output actions.  
2. Click the row containing the output action you wish to delete.  
3. Click the Delete Selected button.  
4. Click the Save button to save the change.  
Configuring Report To File Actions  
The Report to File feature enables you to convert XML, delimited and user  
reports to files that can be sent through the FTP action. The Report to File  
action can be executed from Combination actions, Thresholds, Rules and  
Timed Rules. The EVR1500 system handles up to 25 Report to File actions.  
To configure Report to File actions:  
1. After launching the web GUI, click User - Report to File. The Report to File  
window displays.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
48  
EVR1500 Installer/User Guide  
Figure 3.22: Report to File Window  
2. Click the row containing the Report to File action you wish to configure.  
-or-  
Add a new Report to File action by clicking the Create New button. A new  
row is added to the Report to File table.  
The Report to File action information displays in the dialog box.  
3. Click Enabled to enable the Report to File action.  
NOTE: An enabled Report to File action is available for use in the following operations:  
Combination actions, Thresholds, Rules and Timed Rules.  
4. Type a unique name for the Report to File action in the Unique name field.  
The name cannot contain any spaces. The only special character allowed  
is the underscore (_).  
5. Select the report you want to use for the Report to File action from the  
Report to generate drop-down menu.  
NOTE: The reports displayed in the drop-down menu are XML, delimited and user reports.  
6. Select a report name from the File name to append the report to drop-  
down menu. The system will process the report and save the results in the  
named file.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Basic Operations  
49  
7. Click the Test Selected button to execute the Report to File action. A  
message box displays with the results of the action. Click OK to exit the  
message box.  
8. Click the Save button to save all items in the Configuration tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Configuration tab to the last Save operation.  
To delete a Report to File action:  
1. After launching the web GUI, click Configuration - Report to File. The  
Report to File window displays.  
2. Click the row containing the Report to File action you wish to delete.  
3. Click the Delete Selected button to delete the Report to File action.  
4. Click the Save button to save the change.  
Viewing Logs  
The Logs feature enables you to display a Linux system log file and the five  
most recent application log files. The application logs are deleted after cycling  
from the current log file to the oldest. The system and application logs are  
described as follows:  
System Log: Linux system log  
App. Log - Cur: Current system application messages  
App. Log - 2: Historical log (newest)  
App. Log - 3: Historical log  
App. Log - 4: Historical log  
App. Log - 5: Historical log (oldest)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
50  
EVR1500 Installer/User Guide  
Figure 3.23: Log Output Window  
To view system logs:  
1. After launching the web GUI, click the Logs tab. The Logs window  
displays names of system and application logs.  
2. Click the log file you wish to review. The Log Output window displays the  
contents of the log file you selected.  
NOTE: The size of the log files is limited to 100K. New log messages replace the oldest log  
messages when this file size is exceeded. The timestamps in the log windows are in GMT  
format. The system is set to local time.  
3. Click Refresh to update the view.  
NOTE: The Log Output window is a snapshot view and is not automatically updated.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Operations  
4
Contents  
Setting Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
Configuring Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55  
Configuring Timed Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
Configuring User Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Advanced Operations  
53  
Chapter 4: Advanced Operations  
Setting Thresholds  
The Thresholds feature enables you to set thresholds for analog and digital  
inputs and to configure the frequency that Email, Combination, FTP, Output  
and Report to File actions are processed against the threshold. The EVR1500  
environmental monitor appliance handles up to 25 thresholds.  
The threshold information shown in Figure 4.1 is used to monitor a  
temperature probe connected to an analog input. The threshold will monitor  
the selected analog input (Analog_in01) every 60 seconds. If the value of  
Analog_in01 meets or exceeds 85 degrees F, the selected Combination action  
(Combo_Action1) will execute. The Combination action will execute one time  
and then wait for the release value to reset. Once it is reset, the action will  
execute again if 85 degrees F is exceeded. A threshold action is reset when the  
temperature sensor first reports an input voltage that is less than the release  
value of 75 degrees F. Once the temperature has dropped below 75 degrees F,  
the action is reset.  
Figure 4.1: Thresholds Window  
Download from Www.Somanuals.com. All Manuals Search And Download.  
54  
EVR1500 Installer/User Guide  
To configure a threshold:  
1. After launching the web GUI, click Application - Thresholds. The  
Thresholds window displays thresholds configured in the system.  
2. Click Create New to add a new threshold to the list. A new row is added to  
the thresholds table.  
-or-  
Click the threshold you wish to configure.  
The threshold information displays in the dialog box.  
3. Click the Enabled checkbox to enable the threshold. An enabled threshold  
is processed at the selected frequency by the system.  
4. Type a new name for the threshold in the Unique name field. The name  
cannot contain any spaces. The only special character allowed is  
the underscore (_).  
5. Type a new value (in seconds) in the Frequency of testing in seconds field.  
The value you enter is the frequency that the system will evaluate the  
enabled threshold.  
6. Select an input from the Value to test drop-down menu.  
7. Enter a new value in the Threshold value for action to fire field.  
8. Enter a new value in the Release value for the threshold field.  
NOTE: If the Trig value is greater than the Rel value, the threshold is a Trigger High Event; if the  
Trig value is less than the Rel value, the threshold is a Trigger Low Event.  
9. Select an action from the Action to fire drop-down menu. All enabled  
actions will display in the list. This action is executed when the threshold  
has been exceeded.  
NOTE: The action will execute once when the threshold has been exceeded and will wait for  
the release value to reset. Once the value has been reset, the action will execute again, if the  
threshold is exceeded.  
10. After configuring the new or existing threshold, click the Test Selected  
button to evaluate the input, the Trig/Rel values and the state of the  
threshold. This command also executes the action, if the values are  
appropriate. A message box displays with the results of the test. Click OK to  
exit the message box.  
11. Click the Save button to save the configuration items in the Application tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Application tab to the last Save operation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Advanced Operations  
55  
To delete a threshold:  
1. After launching the web GUI, click Application - Thresholds. The  
Thresholds window displays a list of thresholds.  
2. Click the row containing the threshold you wish to delete.  
3. Click the Delete button to delete the selected threshold.  
4. Click the Save button to save the change.  
Configuring Rules  
The Rules feature enables you to configure periodic if-then-else rules used to  
process Email, SNMP Traps, Combination, FTP, Output and Report to File  
actions. Using the Rules feature, you can also edit, test and delete an existing  
rule. The system can handle up to 25 rules.  
The rule shown in Figure 4.2 is used to control a fan connected to a digital  
output. The value in the Value to test field (Temp1) is a calculation that will  
equal 1 if an analog input exceeds 85 degrees F. If the analog input falls below  
85 degrees F, the Temp1 calculation will equal Ø. This rule scans the Fan_  
Temp calculation every 60 seconds and either turns the output connected to  
the fan on (Temp1 = 1) or off (Temp1 = Ø). An output action is used to toggle  
the digital output.  
Figure 4.2: Rules Window  
Download from Www.Somanuals.com. All Manuals Search And Download.  
56  
EVR1500 Installer/User Guide  
To configure a rule:  
1. After launching the web GUI, click Application - Rules. The Rules window  
displays a list of rules.  
2. Click Create New to add a rule. A row is added to the rules table.  
-or-  
Click the rule you wish to edit.  
The rules information displays in the dialog box.  
3. Click the Enabled checkbox to enable the rule. An enabled rule is  
processed periodically by the system.  
4. Type a new name for the rule in the Unique name field. The name cannot  
contain any spaces. The only special character allowed is the underscore (_).  
5. Type a new value (in seconds) in the Frequency of testing in seconds field.  
The value you type is the frequency that the system will process the  
enabled rule.  
6. Select an input from the Value to test drop-down menu.  
7. Select an option from the Action to fire if true drop-down menu. You must  
select an option from this list if the option is a rule for an enabled Email,  
SNMP Trap, Combination, FTP, Output or Report to File action.  
8. (Optional) Select an option from the Action to fire if false drop-down menu.  
9. After configuring the new or existing rule, click the Test Selected button to  
evaluate the rule. A message box displays with the results of the test. Click  
OK to exit the message box.  
NOTE: When a rule is evaluated by the system, the Input (value) is evaluated. If the Input is a  
non-zero value, the Action to fire if true action is executed. If the If input is Ø, the Action to fire if  
false action is executed.  
10. Click the Save button to save all items in the Application tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Application tab to the last Save operation.  
To delete a rule:  
1. After launching the web GUI, click Application - Rules. The Rules window  
displays a list of rules.  
2. Click the row containing the rules you wish to delete.  
3. Click the Delete button to delete the selected rule.  
4. Click the Save button to save the change.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Advanced Operations  
57  
Configuring Timed Rules  
From the Timed Rules window, you can configure the frequency that the timed  
rules operation will process Email, Combination, FTP, Output and Report to  
File actions. Using the Timed Rules feature, you also can edit, test and delete  
an existing timed rule. The system handles up to 25 timed rules.  
The timed rule shown in Figure 4.3 is used to send the FTP_Temp_File  
(action) every 60 minutes. The FTP file contains one report or several reports  
written to a file (Temp_File) using the Report to File action. Before configuring  
a timed rule, you must create the FTP action (FTP_Temp_File) using the FTP  
option in the Configuration tab.  
Figure 4.3: Timed Rules Window  
To configure a timed rule:  
NOTE: When a timed rule is evaluated by the system, the Freq(Min) value is evaluated against  
the system clock. If appropriate, the action is processed.  
1. After launching the web GUI, click Application - Timed Rules. The Timed  
Rules window displays a list of timed rules.  
2. Click Create New to add a new timed rule. A new row is added to the  
Timed Rules table.  
-or -  
Click the timed rule you wish to configure.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
58  
EVR1500 Installer/User Guide  
The timed rule information displays in the dialog box.  
3. Click the Enabled checkbox to enable the timed rule. An enabled timed  
rule is processed periodically by the system.  
4. Type a new name for the timed rule in the Unique name field. The name  
cannot contain any spaces. The only special character allowed is  
the underscore (_).  
5. Select a new value (in minutes) from the Frequency for action to fire  
drop-down menu. The number of minutes you select is the frequency that  
the system will process the enabled timed rule. For example, if you select 5  
from the list, the timed rule will execute its action at five-minute intervals.  
6. Select an action from the Action to fire drop-down menu.  
7. After configuring the new or existing timed rule, click the Test Selected  
button to evaluate the timed rule. A message box displays with the results  
of the test. Click OK to exit the message box.  
8. Click the Save button to save all configuration items in the Application tab.  
- or -  
Click the Cancel button to revert all configuration items in the  
Application tab to the last Save operation.  
To delete a timed rule:  
1. After launching the web GUI, click Application - Timed Rules. The Timed  
Rules window displays a list of timed rules.  
2. Click the row containing the timed rule you wish to delete.  
3. Click the Delete button to delete the selected timed rule.  
4. Click the Save button to save the change.  
Configuring User Security  
The User Security feature enables the system administrator to set custom  
security levels, including Full Access, View Only Access or No Access for each  
user in the system.  
To configure user security:  
1. After launching the web GUI, click System - User Security. The User  
Security window displays.  
2. Click Add to add a new user. In the dialog box that displays, enter your  
username and click OK. A dialog box displays. A new row is added to the  
User Name list.  
-or -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Advanced Operations  
59  
Click a username to edit security settings. A dialog box displays drop-  
down menus for configuring user privileges.  
Figure 4.4: User Security Window  
3. Click the Set Password button to set the password for the selected user.  
4. Configure user access to the system by selecting options from the drop-  
down menu for each feature tab.  
- or -  
Under Set All Tabs, click None, View Only or Full to set all tabs to a  
single setting as follows:  
• None - The user cannot view or select the tab.  
• View Only - The user can view, but not edit, tab information.  
• Full - The user can view and edit tab information.  
5. Click Save to save the change.  
-or-  
Click the Cancel button to revert all configuration items in the System  
tab to the last Save operation.  
To delete user security settings:  
1. Click System - User Security. The User Security window displays a list of  
user security settings.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
60  
EVR1500 Installer/User Guide  
2. Click the username you wish to delete.  
NOTE: You cannot delete the admin account.  
3. Click the Delete button to delete the selected user.  
4. Click the Save button to save the change.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
Contents  
Appendix A: Application Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . 63  
Appendix B: Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . 65  
Appendix C: EVR1500 Environmental Monitor Appliance Pinouts . . 67  
Appendix D: SNMP Trap MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70  
Appendix E: Customer-Supplied Sensors . . . . . . . . . . . . . . . . . . . . . 72  
Appendix F: Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
63  
Appendices  
Appendix A: Application Updates  
The Application Update feature enables you to update the EVR1500  
environmental monitor appliance with the latest version of the system Java  
JAR file. To perform this update, you will need an FTP or HTTP (Hypertext  
Transfer Protocol) server to store the new file.  
To update the JAR file:  
1. Verify that the updated JAR file is located on an FTP or HTTP server and  
determine the exact directory address and filename of the file.  
2. After launching the web GUI, click System - Application Update. The  
Application Update window displays.  
Figure A.1: Application Update Window  
updated Avocent.JAR file.  
4. Click the URL field in the Application Update window and type the URL  
of the JAR file. For example:  
FTP://USERID:[email protected]/  
EVR1500/Softwaredownloads/Avocent.JAR  
NOTE: You must supply a user ID and password that is valid for the FTP server  
on 192.168.1.10.  
5. Click the Load button. Wait for a message indicating that the file has  
downloaded successfully.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
64  
EVR1500 Installer/User Guide  
6. Click the Restart button to complete the upload. Wait for a few minutes for  
the system to restart.  
7. Clear the temporary cache files on your PC as follows:  
a.  
From Internet Explorer, click Tools - Internet Options. The Internet  
Options dialog box displays. In the Internet Options dialog box, select  
Temporary Internet Files - Delete Files.  
b.  
From the Windows Start menu, click Settings - Control Panel. In the  
Control Panel, double-click the JAVA Plug-in icon. In the Java Plug-in  
Control Panel, click the Cache tab. Confirm the operation by clicking  
yes in the Confirmation Needed message box.  
8. Close Internet Explorer and log in again.  
9. Click the Main tab and verify the new version of the application in the  
System Summary section.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
65  
Appendix B: Technical Specifications  
EVR1500 Environmental Monitor Appliance Specifications  
USB Ports  
Number  
Types  
Connectors  
Configuration Port  
Number  
2
USB 1.0 compliant  
RJ-45  
1
Type  
Connector  
Setup  
Serial RS-232  
DB9 male  
Baud Rate: 38.4 KBPS; Bits: 8; Parity: None;  
Stop Bits: 1  
Network Connection  
Number  
1
Type  
Connector  
Ethernet: IEEE 802.3, 10/100BaseT,  
RJ-45  
Analog Input Sensor Ports  
Number  
Type  
Resolution  
Connector  
Power  
8
Voltage input: 0 to 40 V range  
20 bit A/D converter; 238.4 uV/bit  
RJ-45  
Each port outputs 12 VDC to power sensors  
Sensors supplied by Avocent or a third party  
Supports  
Digital Input Sensor Ports  
Number  
6
Type  
Contact closure; 2 pins per connector  
Connector  
Phoenix-style removable plug-in; accepts  
bare wire; terminals 1 to 6  
Supports  
Sensors supplied by Avocent or a third party  
Digital Output Sensor Ports  
Number  
Type  
2
Open Collector; current sink  
Connector  
Phoenix-style removable plug-in; accepts  
bare wire; terminals 7 to 8  
Output voltage  
Sink current  
+5 VDC  
100 mA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
66  
EVR1500 Installer/User Guide  
EVR1500 Environmental Monitor Appliance Specifications (continued)  
Dimensions  
Dimensions (H x W x D)  
4.2 x 21.5 x 20.5 cm 1U form factor  
(1.75 x 8.5 x 8 in)  
Weight  
Power consumption  
Input power  
3.5 lbs without cables  
25 W  
+5 VDC/+12 VDC supplied from  
external DC power brick  
AC-input voltage rating  
AC-input frequency rating  
AC-input current rating  
AC-input cable  
90 to 264  
47 to 63 Hz  
1.35 Amps @ 115 VAC  
18 AWG four-wire cable, from brick to appliance  
(supplied); IEC-320 receptable accepts country-  
specific cords for connection from unit to wall  
(not supplied)  
Humidity  
10 to 95% noncondensing  
32° F to 104° F (0° to 40° C)  
-4° F to 158° F (-20° C to 70° C)  
Operating temperature  
Storage temperature  
EMC and Safety Approvals  
USA (UL, FCC), Canada (cUL), European Union (CE), Japan (VCCI),  
Australia (C-tick)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
67  
Appendix C: EVR1500 Environmental Monitor  
Appliance Pinouts  
This appendix provides pinouts and signal definitions for the following  
EVR1500 environmental monitor appliance connectors: analog sensors (RJ-  
45), digital I/O (eight-wire insert), COM1 (RS-232) serial port, Ethernet 10/100  
BaseT and VGA display. Figure C.1 shows the digital I/O connections on the  
appliance terminal blocks.  
Analog Sensor Connectors  
RJ-45 Pin  
Signal Name  
GND  
N/C  
Description  
1
2
3
4
5
6
7
8
Signal ground  
Not connected  
Not connected  
Not connected  
Voltage input  
N/C  
N/C  
Vin  
NC  
Not connected  
Not connected  
+12VDC output  
N/C  
+12VDC  
Digital I/O connectors  
Each digital I/O requires two connections, as shown in Figure C.1. Digital  
inputs (1 to 6) connect to dry contact closures. Digital outputs (7 and 8) provide  
Ø or 5 VDC and require ground connection.  
1
2
3
4
5
6
7
8
Dry Contacts  
0, 5 VDC  
Figure C.1: Digital Sensor Connections on Terminal Blocks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
68  
EVR1500 Installer/User Guide  
COM 1 Serial Port Connector  
RS-232  
Signal Name  
DCD  
RXD  
Description  
1
2
3
4
5
6
7
8
9
Data carrier detect  
Receive data  
TXD  
Transmit data  
DTR  
Data terminal ready  
Signal ground  
GND  
DSR  
Data set ready  
Transmit ready to send  
Clear to send  
TRTS  
CTS  
RI  
Receive interrupt  
Ethernet 10/100 BaseT Connector  
Pin  
1
Signal Name  
XMIT+  
XMIT-  
RCV+  
N/C  
Description  
Transmit output  
Transmit input  
Receive output  
Not connected  
Not connected  
Receive input  
Not connected  
Not connected  
2
3
4
5
N/C  
6
RCV-  
7
N/C  
8
N/C  
VGA Display Connector  
Pin  
1
Signal Name  
Red  
Description  
Red  
2
Green  
Blue  
Green  
3
Blue  
4
N/C  
Not connected  
Signal ground  
Signal ground  
Signal ground  
Signal ground  
Battery  
5
GND  
6
GND  
7
GND  
8
GND  
9
VDDC  
GND  
10  
Signal ground  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
69  
VGA Display Connector (continued)  
Pin  
11  
Signal Name  
N/C  
Description  
Not connected  
DDC data  
12  
13  
14  
15  
DDC DAT  
H-SYNC  
V-SYNC  
DDC CL  
Horizontal synchronization  
Vertical synchronization  
DDC clock  
Download from Www.Somanuals.com. All Manuals Search And Download.  
70  
EVR1500 Installer/User Guide  
Appendix D: SNMP Trap MIB  
This appendix provides the SNMP trap MIB definitions. The EVR1500  
environmental monitor appliance supports pre-configured traps, which can be  
used in Combination actions, Thresholds, Rules and Timed Rules.  
EVR1500 Environmental Monitor Appliance Trap MIB Definitions  
evr1500TrapValueName  
Type  
Object-Type  
Description  
This object is sent in a trap to identify the configured name  
of the trap value.  
Syntax  
evr1500TrapValue  
Type  
Octet String (Size (1..25))  
Object-Type  
Description  
This object is sent in a trap to give the value read on  
the sensor.  
Syntax  
Octet String (Size (1..25))  
evr1500TrapInternalTempHIGH  
Type  
Trap-Type  
Description  
The internal temperature sensor has sampled a value that  
exceeds the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
evr1500TrapInternalTempLOW  
Type  
Trap-Type  
Description  
The internal temperature sensor has sampled a value that is  
below the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
evr1500TrapInternalHumidityHIGH  
Type  
Trap-Type  
Description  
The internal humidity sensor has sampled a value that  
exceeds the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
evr1500TrapInternalHumidityLOW  
Type  
Trap-Type  
Description  
The internal humidity sensor has sampled a value that is  
below the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
71  
EVR1500 Environmental Monitor Appliance Trap MIB  
Definitions (continued)  
evr1500TrapInternalAirFlowHIGH  
Type  
Trap-Type  
Description  
The internal air flow sensor has sampled a value that  
exceeds the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
evr1500TrapInternalAirFLowLOW  
Type  
Trap-Type  
Description  
The internal air flow sensor has sampled a value that is  
below the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
evr1500TrapInternalAudioHIGH  
Type  
Trap-Type  
Description  
The internal audio sensor has sampled a value that exceeds  
the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
evr1500TrapInternalAudioLOW  
Type  
Trap-Type  
Description  
The internal temperature sensor has sampled a value that  
below the configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
evr1500TrapThresholdHIGH  
Type  
Trap-Type  
Description  
The channel sensor has sampled a value that exceeds the  
configured threshold.  
Variables  
{ evr1500TrapIValueName,  
evr1500TrapValue }  
evr1500TrapThresholdLOW  
Type  
Trap-Type  
Description  
The channel sensor has sampled a value that is below the  
configured threshold.  
Variables  
{ evr1500TrapValueName,  
evr1500TrapValue }  
Download from Www.Somanuals.com. All Manuals Search And Download.  
72  
EVR1500 Installer/User Guide  
Appendix E: Customer-Supplied Sensors  
Customer-supplied sensors used with the EVR1500 environmental monitor  
appliance must meet the requirements shown in the following table.  
Requirements for Customer-Supplied Sensors  
Analog Sensors  
Requirements  
Power  
Must accept 12VDC if powered by EVR1500  
environmental monitor appliance.  
Input Voltage  
Input Current  
Pinout for RJ-45  
Positive voltage between Ø to 40 V;  
Example input minimum voltages are 1, 0, 0, 2.  
Example input maximum voltages are 5, 5, 10, 10.  
4-20 mA sensors can be used with an external resistor  
or the internal jumpers. Contact Avocent  
Technical Support.  
Pin 1, ground.  
Pin 5, voltage input (from sensor to EVR1500  
environmental monitor appliance).  
Pin 8, - +12V output (from EVR1500 environmental  
monitor appliance to sensor).  
Scale  
Linear input required.  
Digital Sensors  
Input Voltage  
Pinout  
Ø to 5 VDC.  
See Appendix C.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
73  
Appendix F: Technical Support  
Our Technical Support staff is ready to assist you with any installation or  
operating issues you encounter with your Avocent product. If an issue should  
develop, follow the steps below for the fastest possible service:  
1. Check the pertinent section of this manual to see if the issue can be  
resolved by following the procedures outlined.  
base or use the on-line service request.  
3. Call Avocent Technical Support for assistance at (888) 793-8763. Visit the  
Phone Numbers for current phone support hours.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
74  
EVR Installer/User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
76  
EVR Installer/User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
Avocent Corporation warrants to the original retail purchaser that this product is and will be free from  
defects in materials and workmanship for a period of 24 months from the date of purchase.  
Additionally, all Avocent products carry an unconditional thirty-day satisfaction guarantee. If, for any  
reason, you are dissatisfied with the performance of this product, you may return it to the point of  
purchase for a refund of the purchase price (excluding shipping charges). This guarantee does not  
apply to special order products, and may not be available through all resellers. During the warranty  
period, purchaser must promptly call Avocent for a RETURN MATERIALS AUTHORIZATION (RMA)  
number. Make sure that the RMA number appears on the packing slip, proof of purchase, AND ON THE  
OUTSIDE OF EACH SHIPPING CARTON. Unauthorized returns or collect shipments will be refused.  
Ship prepaid to:  
Avocent Corporation  
4991 Corporate Drive  
Huntsville, AL 35805 U.S.A.  
Telephone: (256) 430-4000  
The above limited warranty is voided by occurrence of any of the following events, upon which the  
product is provided as is, with all faults, and with all disclaimers of warranty identified below:  
1. If defect or malfunction was caused by abuse, mishandling, unauthorized repair, or use other  
than intended.  
2. If unauthorized modifications were made to product.  
3. If unreported damages occurred in any shipment of the product.  
4. If damages were due to or caused by equipment or software not provided by Avocent.  
5. If the unit is used with non-grounded or incorrectly polarized AC power.  
6. If the product is used in contradiction to any instruction provided by any User Guide or Instruction  
Sheet provided to you or with the product.  
7. If the product is damaged due to power surges, water exposure or act of God including lightning.  
EXCEPT AS SPECIFICALLY PROVIDED ABOVE AND TO THE MAXIMUM EXTENT ALLOWED BY  
LAW, AVOCENT CORPORATION DISCLAIMS ALL WARRANTIES AND CONDITIONS WHETHER  
EXPRESS, IMPLIED, OR STATUTORY AS TO ANY MATTER WHATSOEVER INCLUDING, WITHOUT  
LIMITATION, TITLE, NON-INFRINGEMENT, CONDITION, MERCHANTABILITY OR FITNESS FOR  
ANY PARTICULAR OR INTENDED PURPOSE.  
EXCEPT AS EXPRESSLY PROVIDED ABOVE AND TO THE MAXIMUM EXTENT ALLOWED BY  
LAW, AVOCENT CORPORATION SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT OR  
CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION, LOSS OF PROFIT, LOSS OF  
BUSINESS, LOSS OF INFORMATION, FINANCIAL LOSS, PERSONAL INJURY, LOSS OF PRIVACY OR  
NEGLIGENCE) WHICH MAY BE CAUSED BY OR RELATED TO, DIRECTLY OR INDIRECTLY, THE  
USEOFAPRODUCTORSERVICE,THEINABILITYTOUSEAPRODUCTORSERVICE,INADEQUACY  
OF A PRODUCT OR SERVICE FOR ANY PURPOSE OR USE THEREOF OR BY ANY DEFECT OR  
DEFICIENCYTHEREINEVENIFAVOCENTCORPORATIONORANAUTHORIZEDAVOCENTDEALER  
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES.  
©2004 Avocent Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For Technical Support:  
Avocent International Ltd.  
Avocent House, Shannon Free Zone  
Shannon, County Clare, Ireland  
Tel: +353 61 715 292  
Avocent Corporation  
4991 Corporate Drive  
Huntsville, Alabama 35805-6201 USA  
Tel: +1 256 430 4000  
Fax: +1 256 430 4031  
Fax: +353 61 471 871  
Avocent Germany  
Avocent Asia Pacific  
Singapore Branch Office  
100 Tras Street, #15-01  
Amara Corporate Tower  
Singapore 079027  
Gottlieb-Daimler-Straße 2-4  
D-33803 Steinhagen  
Germany  
Tel: +49 5204 9134 0  
Fax: +49 5204 9134 99  
Tel: +656 227 3773  
Fax: +656 223 9155  
Avocent Canada  
50 Mural Street, Unit 5  
Richmond Hill, Ontario  
L4B 1E4 Canada  
Tel: +1 877 992 9239  
Fax: +1 877 524 2985  
590-375-001B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Switch 3226 User Manual
Accusplit Heart Rate Monitor AX740SBL User Manual
Acer Projector PD724 series User Manual
ACP EP Memory Camera Accessories CF120X User Manual
Aiphone Home Security System MY 1AD User Manual
Allied Telesis Switch AT FS705L User Manual
Amana Cooktop AEZ8581 User Manual
Atlona Car Amplifier AT HD19SS User Manual
Atlona TV Cables ATP 14009 User Manual
Beckett Water Gardening Outdoor Fountain CGFK60 User Manual