American Standard Hot Tub Whirlpool Bathing Pool User Manual |
TOWN SQUARE®
6' x 42"™
INSTALLATION
INSTRUCTIONS
2742.XXXX SERIES WHIRLPOOL / BATHING POOL
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
THANK YOU...
for selecting an American Standard bath. Your
new bath is shipped to you after careful
inspection. The whirlpool version is completely
assembled with pump, motor, and system
piping. All you need to finish the installation
are your selected fittings and electrical
connections for a whirlpool.
71-1/2"
(1816mm)
4"
3"
(76mm)
(102mm)
INTEGRAL
FITTING DECK
3" X 14"
35-3/4"
(908mm)
13-1/4"
(337mm)
C/L OF DRAIN OUTLET
(76 X 356mm)
EDGE OF
FLOOR
CUTOUT
To insure maximum performance and pleasure
from this product, please follow the
instructions and cautions.
PROVIDE ACCESS
TO PUMP FOR
SERVICE ON ALL
INSTALLATIONS
41-3/4"
(1060mm)
FLOOR CUTOUT
5" X 15"
(127 X 381mm)
26-3/4
(679mm)
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
List of Required Components (not included):
• Drain 1594.170
• Bath Filler
3/4"
(19mm)
PUMP
ON/OFF
SWITCH
OUTLINE OF CUTOUT
70" X 40-1/4"
(1778 X 1022mm)
SUCTION
List of Required Tools and Supplies:
JETS (8)
SAFE-T-
HEATER
REMOVABLE
BLANK
Tools
Supplies
• Level
• Nails
LEVELING STRINGER
(NOT FOR SUPPORT)
2"
(51mm)
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
• Putty
C/L OF
OVERFLOW
PUMP
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
22"
(559mm)
• Drop Cloth
3-1/4"
(83mm)
Woodworking Tools • 20 amp GFI Outlet
20"
(508mm)
ROUGH
FLOOR
• Cement, Plaster,
Grout
• Personal Safety
Equipment
• Caulking Gun
INTEGRAL
FEET
SUPPORT
1-1/2" N.P.T. THREADS
1-1/2" O.D.TAILPIECE
GENERAL INSTALLATION INFORMATION
3"
(76mm)
5/8"
(16mm)
Carefully uncrate and inspect your new bath for
any shipping damage. If such damage is found,
report it to your vendor immediately.
After inspection and during installation, protect
the bath from construction damage. After
installation, and before enclosing with wallboard,
tile, etc., water test the unit and check for leaks.
GENERAL SPECIFICATIONS FOR 2742 WHIRLPOOL
INSTALLED SIZE
71-1/2 x 41-3/4 x 22 In. (1816 x 1060 x 559mm)
WEIGHT
115 Lbs. (52 Kg.)
690 Lbs. (313 Kg.)
Do not make modifications to the whirlpool
system or remove pump from factory mounting.
This could adversely affect the safety and
performance of the whirlpool and void the
warranty. Do not handle or move the whirlpool by
the pump, motor, or piping system.
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
69 Gal. (261 L)
60 Gal. (227 L)
41 x 21-1/2 In. (1041 x 546mm)
62 x 31-1/2 In. (1574 x 800mm)
14-1/4 In. (362mm)
33 Lbs./Sq.Ft. (163 Kgs./Sq.m)
(PROJECTED AREA)
PTS.
Fittings (bath filler, shower arm, etc.) are not
provided with the bath and must be ordered
separately. Framing and enclosing materials are
provided by others.
27.8
55.7
CUBE (FT3)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
WHIRLPOOL PUMP
2.1 HP, 14.4 AMPS ,120V.
Protect all finished surfaces of the whirlpool
during construction and installation using a drop
cloth.
WARNING! Do not lift whirlpool by the piping
harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
© AS America Inc. 2009
753027-100 REV. F
All product names listed herein are trademarks
of AS America Inc. unless otherwise noted.
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other
applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1.
DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
Grounding is required. The unit should be installed by a licensed electrician and grounded.
Install to permit access for servicing.
2.
3.
4.
All building materials and wiring should be routed away from the pump body and heater (if equipped).
The air massage version should be installed on a 120 vac, 15 amp dedicated circuit. The whirlpool version should be
installed on a 120 vac, 20 amp dedicated circuit. The combination system requires a 120 vac, 20 amp dedicated circuit
for the whirlpool pump and a 120 vac, 15 amp dedicated circuit for the air pump. Each circuit must be a three (3) wire
circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING
THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.
ELECTRICAL INSTALLATION
FOR AIR MASSAGE : SEPARATE 15 AMP GFCI OUTLET
FOR WHIRLPOOL : SEPARATE 20 AMP GFCI OUTLET
FOR COMBINATION SYSTEMS : SEPARATE 15 AMP GFCI OUTLET
(AIR PUMP) AND A SEPARATE 20 AMP GFCI OUTLET (WHIRLPOOL PUMP)
WHIRLPOOL MOUNTED
120 VAC
AIR SWITCH OR
WALL TIMER
PUMP/MOTOR
GND.
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
(3)
753027-100 REV. F
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRE SELECTION GUIDE
Maximum distance from
fusebox to motor
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
Motor
Hi Performance
Rating
50'
100' 150'
120V Power Line
10
200'
electrical codes
2.1
12
8
8
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the
pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of
the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings
are factory tightened and inspected, some loosening may have occurred during transit.) Make sure the whirlpool is
connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the
whirlpool is running.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or
®
stains may be removed using granular Spic and Span mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
FEATURES of YOUR NEW AMERICAN STANDARD ACRYLIC BATHTUB
Your new acrylic bathtub has been molded in the newest plumbing fixture material available today. Acrylics are
tough durable finishes that are simple and easy to care for.
The colors have been formulated to match other American Standard fixtures and enhance your choice of
bathroom decorations. The high gloss surface is resistant to impact and chemicals and will retain its lasting
luster with proper care and maintenance.
AFTERCARE and CLEANING
• Always fill the tub with temperate water. Excessively hot water may cause surface damage
• Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.
• Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil, Lysol Disinfectant (spray
or concentrate), or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean, Dow Disinfectant Bathroom Cleaner,
or cleaning products in aerosol cans.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
• Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits, or other surface
blemishes.
• Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses
its sheen, dulled areas can be restored by rubbing with a white "automotive type" polishing compound and
waxing with a "liquid wax."
• Do not wax areas where you walk or stand.
• Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into
contact with the surface.
• Clean the surrounding surface immediately after using caustic drain cleaners.
• Burning cigarettes will damage the surface.
• Should damage to the fixture occur, repairs can be made quickly and easily.
Your distributor or builder can provide details.
* For Air Massage and Combination systems, please refer to the Installation and Operating Manual for Air Massage and
Combination Systems (P/N 753036-100) for additional information.
®
(4)
SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
753027-100 REV. F
Download from Www.Somanuals.com. All Manuals Search And Download.
|