TECHNICAL MANUAL
ASX 14 SEER
Condensing Units
•
•
•
•
Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
RT6113004r10
October2011
is a registered trademark of Maytag Corporation or its related companies and is used under
license to Goodman Company, L.P., Houston, TX. All rights reserved.
Copyright © 2006-2011 Goodman Company, L.P.
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
ASX140181A*
ASX140241A*
ASX140301A*
ASX140361A*
ASX140421A*
ASX140481A*
ASX140601A*
ASX140181C*
ASX140241C*
ASX140301C*
ASX140361C*
ASX140421C*
ASX140481C*
ASX140181D*
ASX140421D*
ASX140181B*
ASX140241B*
ASX140301B*
ASX140361B*
ASX140421B*
ASX140481B*
ASX140601B
* Indicates minor revision & is not used for order entry or inventory management
The United States Environmental Protection Agency (“EPA”) has issued various regulations re-
garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
WARNING
WARNING
Do not connect or use any device
To prevent the risk of property
WARNING
that is not design certified by
damage, personal injury, or death,
Goodman for use with this unit.
do not store combustible materials or use gasoline or
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
other flammable liquids or vapors in the vicinity of this
appliance.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DESIGN
ASX14 models are available in 1 1/2 through 5 ton sizes and
use R-410A refrigerant. They are designed for 208/230 volt
single phase applications.
completely unobstructed; however, if vertical conditions re-
quire placement beneath an obstruction there should be a
minimum of 60 inches between the top of the unit and
the obstruction(s). The specified dimensions meet require-
ments for air circulation only. Consult all appropriate regula-
tory codes prior to determining final clearances.
The condenser air is pulled through the condenser coil by a
direct drive propeller fan. This condenser air is then dis-
charged out of the top of the cabinet.
Another important consideration in selecting a location for
the unit(s) is the angle to obstructions. Either side adjacent
the valves can be placed toward the structure provided the
side away from the structure maintains minimum service clear-
ance. Corner installations are strongly discouraged.
These units are designed for free air discharge, so no addi-
tional resistance like duct work shall be attached.
The suction and liquid line connections on present models
are of the sweat type for field piping with refrigerant type cop-
per. Front seating valves are factory installed to accept the
field run copper. The total refrigerant charge for a normal in-
stallation is factory installed in the condensing unit. ASX units
are charged for the matching evaporator coil and a 15 foot
refrigerant line set.
DO NOT locate the unit:
–
–
–
Directly under a vent termination for a gas appliance.
Within 3 feet of a clothes dryer vent.
Where the refreezing of defrost water would create a
hazard.
Systems should be properly sized by heat gain and loss
calculations made according to methods of the Air Condi-
tioning Contractors Association (ACCA) or equivalent. It is
the contractors responsibility to ensure the system has ad-
equate capacity to heat or cool the conditioned space.
–
Where water may rise into the unit.
ASX models use the Copeland Scroll "Ultratech" Series com-
pressors which are specifically designed for R-410A refriger-
ant. There are a number of design characteristics which are
different from the traditional reciprocating and/or scroll com-
pressors.
NOT
RECOMMENDED
OK!
B
OK!
B
B
B
A
AA
AA
AA
"Ultratech" Series scroll compressors will not have a dis-
charge thermostat, some of the early model scroll compres-
sors required discharge thermostats.
OK!
C
C
OK!
AA
AA
AA
OK!
OK!
Due to their design Scroll compressors are inherently more
tolerant of small quantities of liquid refrigerant.
AA
A
NOTE: Even though the compressor section of a Scroll com-
pressor is more tolerant of liquid refrigerant, continued
floodback or flooded start conditions may wash oil from the
bearing surfaces causing premature bearing failure.
C
C
Minimum Airflow Clearance
"Ultratech" Series scroll compressors use "POE" or
polyolester oil which is NOT compatible with mineral oil based
lubricants like 3GS. "POE" oil must be used if additional oil
is required.
Model Type
Residential
A
B
C
AA
10"
12"
10"
12"
18"
18"
20"
24"
Light Commercial
Operating pressures and amp draws may differ from stan-
dard reciprocating and/or scroll compressors. This informa-
tion may be found in the "Cooling Performance Data" sec-
tion.
WARNING
To avoid possible injury, explosion or death, practice
safe handling of refrigerants.
Special consideration must be given to location of the con-
densing unit(s) in regard to structures, obstructions, other
units, and any/all other factors that may interfere with air
circulation. Where possible, the top of the unit should be
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DESIGN
DIMENSIONS
W
D
H
Model
Dimensions - W x D x H
Model
Dimensions - W x D x H
ASX140181A*
26" x 26" x 32¼"
ASX140361A*
29" x 29" x 34¼"
ASX140181B*
ASX140181C*
ASX140361B*
ASX140361C*
29" x 29" x 32½"
26" x 26" x 27½"
ASX140181D*
ASX140421A*
ASX140421B*
35½" x 35½" x 38¼"
29" x 29" x 38¼"
ASX140241A*
26" x 26" x 32½"
26" x 26" x 32½"
ASX140241B*
ASX140241C*
ASX140421C*
ASX140421D*
29" x 29" x 36¼"
35½" x 35½" x 38¼"
35½" x 35½" x 36¼"
ASX140481A*
ASX140481B*
ASX140301A*
29" x 29" x 32¼"
29" x 29" x 32½"
ASX140301B*
ASX140301C*
ASX140481C*
ASX140601A*
ASX140601B*
35½" x 35½" x 38¼"
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CONDENSING UNIT SPECIFICATIONS
ASX140181A* - ASX140361A*
ASX140181A*
ASX140241A*
ASX140301A*
ASX140361A*
Cooling Capacity, BTUH
18,000
24,000
30,000
36,000
Compressor
R.L. Amps
L.R. Amps
9.00
48.0
13.4
58.3
12.8
64.0
14.1
77.0
Low Pressure Switch
Open
Close
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower
1/12
0.6
1/12
0.6
1/6
1.5
1/4
1.6
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
3/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
7/8"
121.0
208/230-60-1
11.8
126.0
208/230-60-1
17.4
131.0
208/230-60-1
17.5
146.0
208/230-60-1
19.2
Minimum Circuit Ampacity(1)
Maximum Overcurrent Device(2)
Electrical Conduit Size
20
30
30
30
Power Supply (Inches)
1/2 or 3/4
178
1/2 or 3/4
178
1/2 or 3/4
195
1/2 or 3/4
199
Approximate Shipping Weight
ASX140421A* - ASX140[48-60]1A* / ASX140[48-60]1B*
ASX140481
AA/AB/AC
ASX140481
AD/B*
ASX140601A*
ASX140601B*
ASX140421A*
Cooling Capacity, BTUH
42,000
48,000
48,000
60,000
Compressor
R.L. Amps
17.9
19.8
19.8
26.4
L.R. Amps
Low Pressure Switch
Open
112.0
109.0
109.0
134.0
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
Close
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower
1/4
1.6
1/4
1.6
1/4
1.6
1/4
1.6
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
Minimum Circuit Ampacity(1)
Maximum Overcurrent Device(2)
Electrical Conduit Size
3/8"
3/8"
3/8"
3/8"
7/8"
7/8"
7/8"
7/8"
180.0
208/230-60-1
24.0
186.0
208/230-60-1
26.4
189.0
208/230-60-1
26.4
271.0
208/230-60-1
34.6
40
40
40
60
Power Supply (Inches)
1/2 or 3/4
207
1/2 or 3/4
242
1/2 or 3/4
242
1/2 or 3/4
280
Approximate Shipping Weight
*
Up to 24' in equivalent line length
(1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuses or HACR type Circuit Breaker of the same size as noted.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
CONDENSING UNIT SPECIFICATIONS
ASX140181B* - ASX140361B* / ASX140181C* - ASX140361C*
ASX140181B*
ASX140181C*
ASX140241B*
ASX140241C*
ASX140301B*
ASX140301C*
ASX140361B*
ASX140361C*
Cooling Capacity, BTUH
18,000
24,000
28,800
34,600
Compressor
R.L. Amps
L.R. Amps
9.00
48.0
13.5
58.3
12.8
64.0
14.1
77.0
Low Pressure Switch
Open
Close
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower
1/6
0.9
1/12
0.6
1/6
0.9
1/6
0.9
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
3/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
7/8"
73.0
91.0
96.0
101.0
208/230-60-1
18.5
208/230-60-1
12.2
208/230-60-1
17.5
208/230-60-1
16.9
Minimum Circuit Ampacity(1)
Maximum Overcurrent Device(2)
Electrical Conduit Size
20
30
30
30
Power Supply (Inches)
1/2 or 3/4
146
1/2 or 3/4
156
1/2 or 3/4
172
1/2 or 3/4
172
Approximate Shipping Weight
ASX140421B* - ASX140421C* / ASX140481C*
ASX140421B*
ASX140421C*
ASX140481C*
Cooling Capacity, BTUH
40,000
40,000
46,000
Compressor
R.L. Amps
L.R. Amps
Low Pressure Switch
Open
Close
High Pressure Switch
Open
Close
*
Up to 24' in equivalent line length
(1) Wire size should be determined in
accordance with National Electrical
Codes; extensive wire runs will
require larger wire sizes.
(2) Maximum Overcurrent Protection
Device: MUST use Time Delay
Fuses or HACR type Circuit Breaker
of the same size as noted.
17.9
16.7
79.0
19.9
112.0
109.0
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower
1/6
1.0
1/6
0.9
1/4
1.5
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
3/8"
7/8"
3/8"
7/8"
3/8"
7/8"
167.0
208/230-60-1
140.0
208/230-60-1
147.0
208/230-60-1
Minimum Circuit Ampacity(1)
Maximum Overcurrent Device(2)
Electrical Conduit Size
23.4
40
21.8
35
26.4
45
Power Supply (Inches)
Approximate Shipping Weight
1/2 or 3/4
207
1/2 or 3/4
184
1/2 or 3/4
230
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CONDENSING UNIT SPECIFICATIONS
ASX140181D* / ASX140421D*
ASX140181D*
ASX140421D*
Cooling Capacity, BTUH
18,000
40,000
Compressor
R.L. Amps
L.R. Amps
9.00
48.0
16.7
79.0
Low Pressure Switch
Open
Close
N/A
N/A
22 PSIG
50 PSIG
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower
1/8
1/6
0.9
F.L. Amps
0.7
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
Minimum Circuit Ampacity(1 )
Maximum Overcurrent Device(2)
Electrical Conduit Size
3/8"
3/8"
3/4"
7/8"
73.0
140.0
208/230-60-1
21.8
208/230-60-1
12
20
35
Power Supply (Inches)
1/2 or 3/4
146
1/2 or 3/4
184
Approximate Shipping Weight
*
Up to 24' in equivalent line length
(1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuses or HACR type Circuit Breaker of the same size as noted.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140181A*
9
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140181A*
10
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140181B* / C* / D*
11
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140181B* / C* / D*
12
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140241A*
13
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140241A*
14
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140241B* / C*
15
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140241B* / C*
16
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140301A*
17
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140301A*
18
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140301B* / C*
19
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140301B* / C*
20
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140361A*
21
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140361A*
22
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140361B* / C*
23
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140361B* / C*
24
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140421A*
25
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140421A*
26
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140421B*
27
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140421B*
28
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140421C* / D*
29
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140421C* / D*
30
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140481A* / B*
31
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140481A* / B*
32
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140481C*
33
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140481C*
34
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140601A* / B*
35
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
ASX140601A* / B*
36
Download from Www.Somanuals.com. All Manuals Search And Download.
PERFORMANCE DATA
ASX140[18-60]1A*/ASX140[48-60]1B*
MODEL: ASX140181A* / CA*F3131B6A* + TXV
Conditions: 80°F IDB, 67°F IWB @ 600 CFM
MODEL: ASX140241A* / CA*F3636B6A* W/.057 Orifice,
Conditions: 80°F IDB, 67°F IWB @ 800 CFM
Outdoor
Tem p. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
80°
18,900
18,675
18,450
18,225
18,000
17,550
17,100
16,470
15,840
12,656
12,664
12,668
12,716
12,758
12,674
12,579
12,166
11,750
6,244
6,011
5,782
5,509
5,242
4,876
4,521
4,304
4,090
1,418
1,459
1,500
1,537
1,573
1,604
1,635
1,661
1,688
75°
80°
25,200
24,900
24,600
24,300
24,000
23,400
22,800
21,960
21,120
17,357
17,369
17,375
17,440
17,497
17,383
17,252
16,686
16,115
7,843
7,531
7,225
6,860
6,503
6,017
5,548
5,274
5,005
1,823
1,877
1,932
1,980
2,028
2,068
2,109
2,144
2,179
85°
85°
90°
90°
95°
95°
100°
105°
110°
115°
100°
105°
110°
115°
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
16,680 12,630 4,049 1,527
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
22,239 17,322 4,917 1,967
95°
95°
MODEL: ASX140361A* / CA*F3642C6A* W/.067 Orifice,
Conditions: 80°F IDB, 67°F IWB @ 1150 CFM
MODEL: ASX140301A* / CA*F3642C6A* W/.063 Orifice,
Conditions: 80°F IDB, 67°F IWB @ 1000 CFM
Outdoor
Tem p. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
80°
30,240
29,880
29,520
29,160
28,800
28,080
27,360
26,352
25,344
20,884
20,897
20,905
20,982
21,052
20,915
20,757
20,076
19,389
9,356
8,983
8,615
8,178
7,748
7,165
6,603
6,276
5,955
2,151
2,213
2,275
2,329
2,384
2,430
2,477
2,517
2,557
75°
80°
36,330
35,898
35,465
35,033
34,600
33,735
32,870
31,659
30,448
24,499
24,515
24,524
24,615
24,697
24,535
24,351
23,552
22,746
11,831
11,382
10,941
10,418
9,903
9,200
8,519
8,107
7,702
2,676
2,754
2,833
2,902
2,971
3,030
3,089
3,139
3,190
85°
85°
90°
90°
95°
95°
100°
105°
110°
115°
100°
105°
110°
115°
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
26,687 20,841 5,846 2,315
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
32,062 24,450 7,612 2,883
95°
95°
MODEL: ASX140481[A*/B*] / CA*F4860D6A* W /.079 Orifice,
Conditions: 80°F IDB, 67°F IW B @ 1550 CFM
MODEL: ASX140421A* / CA*F4860C6A* W/.074 Orifice,
Conditions: 80°F IDB, 67°F IWB @ 1300 CFM
Outdoor
Tem p. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
Outdoor
Tem p. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
80°
48,300
47,725
47,150
46,575
46,000
44,850
43,700
42,090
40,480
33,311
33,333
33,345
33,469
33,580
33,361
33,110
32,024
30,927
14,989
14,392
13,805
13,106
12,420
11,489
10,590
10,066
9,553
3,404
3,503
3,602
3,689
3,776
3,850
3,924
3,988
4,052
80°
85°
41,500
41,000
40,500
40,000
39,000
38,000
36,600
35,200
28,216
28,226
28,331
28,425
28,240
28,027
27,108
26,179
13,284
12,774
12,169
11,575
10,760
9,973
3,116
3,204
3,283
3,361
3,428
3,494
3,551
3,609
85°
90°
90°
95°
95°
100°
105°
110°
115°
100°
105°
110°
115°
9,492
9,021
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
37,066 28,141 8,925 3,262
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
42,625 33,244 9,381 3,665
95°
95°
MODEL: ASX140601[A*/B*] / CA*F4860D6A* W/.088 Orifice,
Conditions: 80°F IDB, 67°F IWB @ 1800 CFM
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
80°
58,800
58,100
57,400
56,700
56,000
54,600
53,200
51,240
49,280
39,475
39,501
39,515
39,662
39,794
39,534
39,236
37,949
36,650
19,325
18,599
17,885
17,038
16,206
15,066
13,964
13,291
12,630
4,540
4,682
4,823
4,948
5,073
5,179
5,285
5,377
5,468
85°
90°
95°
100°
105°
110°
115°
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
51,892 39,396 12,496 4,915
95°
37
Download from Www.Somanuals.com. All Manuals Search And Download.
PERFORMANCE DATA ASX140[24-42]1B*/ASX140[18-36]1C*
MODEL: ASX140241[B*/C*] / CA*F3636*6C* W /.055 Orifice,
Conditions: 80°F IDB, 67°F IW B @ 725 CFM
MODEL: ASX140181[B*/C*/D*] / CA*F3636*6C* W/.052 Orifice
Conditions: 80°F IDB, 67°F IWB @ 600 CFM
Outdoor
Tem p. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
Outdoor
Temp. ° F.
Total
Bt uh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
80°
26,100
25,750
25,400
25,100
24,800
24,200
23,600
22,700
21,800
16,704
16,738
16,764
16,817
16,864
16,819
16,756
16,117
15,478
9,396
9,013
8,636
8,283
7,936
7,381
6,844
6,583
6,322
1,860
1,915
1,970
2,020
2,070
2,115
2,160
2,195
2,230
75°
80°
20,000
19,750
19,500
19,250
19,000
18,550
18,100
17,400
16,700
13,600
13,628
13,650
13,668
13,680
13,634
13,575
13,050
12,525
6,400
6,123
5,850
5,583
5,320
4,916
4,525
4,350
4,175
2,260
2,315
2,370
2,415
2,460
2,500
2,540
2,575
2,610
85°
85°
90°
90°
95°
95°
100°
105°
110°
115°
100°
105°
110°
115°
TV A Conditions @ 95° OD DB, 75° ID DB 63° ID WB
23,000 16,790 6,210 1,990
TVA Conditions @ 95° OD DB, 75° ID DB63° IDWB
17,600 13,552 4,048 2,390
95°
95°
MODEL: ASX140361[B*/C*] / CA*F3642*6C* W /.068 Orifice,
Conditions: 80°F IDB, 67°F IW B @ 1,200 CFM
MODEL: ASX140301[B*/C*] / CA*F3642*6C* W /.065 Orifice,
Conditions: 80°F IDB, 67°F IW B @ 1000 CFM
Outdoor
Total
Btuh
Se ns ible
Btuh
Late nt
Btuh
Total
Outdoor
Total
Btuh
Se ns ible
Btuh
Late nt
Btuh
Total
Watts
Te m p. ° F.
Watts
Te m p. ° F.
75°
80°
36,791
36,353
35,915
35,477
35,040
34,164
33,288
32,061
30,835
25,646
25,663
25,672
25,768
25,853
25,684
25,491
24,655
23,811
11,145
10,690
10,243
9,710
9,186
8,479
7,796
7,406
7,024
2,608
2,684
2,760
2,830
2,900
2,955
3,010
3,060
3,110
75°
80°
30,200
29,850
29,500
29,150
28,800
28,100
27,400
26,350
25,300
21,140
21,194
21,240
21,280
21,312
21,216
21,098
20,421
19,734
9,060
8,657
8,260
7,871
7,488
6,885
6,302
5,929
5,566
2,230
2,295
2,360
2,415
2,070
2,520
2,570
2,610
2,650
85°
85°
90°
90°
95°
95°
100°
105°
110°
115°
100°
105°
110°
115°
TV A Conditions @ 95° OD DB, 75° ID DB 63° ID WB
26,700 21,093 5,607 23,800
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
32,500 25,675 6,825 2,790
95°
95°
MODEL:ASX140421B* / CA*F4860C6A* W/.074 Orifice,
Conditions: 80°FIDB, 67°FIWB @ 1300 CFM
Outdoor
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Temp. ° F.
Watts
80°
85°
41,500
41,000
40,500
40,000
39,000
38,000
36,600
35,200
28,216
28,226
28,331
28,425
28,240
28,027
27,108
26,179
13,284
12,774
12,169
11,575
10,760
9,973
3,116
3,204
3,283
3,361
3,428
3,494
3,551
3,609
90°
95°
100°
105°
110°
115°
9,492
9,021
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
37,066 28,141 8,925 3,262
95°
38
Download from Www.Somanuals.com. All Manuals Search And Download.
PERFORMANCE DATA
ASX140421[C/D]* - ASX140481C*
MODEL: ASX140421[C*/D*] / CA*F4860*6B* W/.070 Orifice,
Conditions: 80°F IDB, 67°F IWB @ 1450 CFM
ASX140481C* / CA*F4860*6D* W/.078 Orfice
Conditions: 80°F IDB, 67°F IWB @ 1550 CFM
Outdoor
Te mp. ° F.
Total
Bt uh
Sensible
Btuh
Latent
Btuh
Total
Watts
Outdoor
Temp. ° F.
Total
Bt uh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
80°
85°
90°
42,116
41,614
41,113
40,611
29,985
30,004
30,015
30,127
12,131
11,610
11,098
10,485
2,950
3,040
3,130
3,205
75°
80°
48,300
47,750
47,200
46,600
46,000
44,850
43,700
42,100
40,500
34,776
34,858
34,928
34,950
34,960
34,759
34,523
33,470
32,400
13,524
12,893
12,272
11,650
11,040
10,091
9,177
3,260
3,365
3,470
3,560
3,650
3,725
3,800
3,865
3,930
85°
90°
95°
40,110
39,107
38,105
36,701
35,297
30,227
30,029
29,803
28,826
27,839
9,883
9,078
8,301
7,875
7,458
3,280
3,350
3,420
3,475
3,530
95°
100°
105°
110°
115°
100°
105°
110°
115°
8,631
8,100
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
43,552 35,549 8,003 3,618
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
37,200 30,132 7,068 3,160
95°
95°
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and
high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 2 degrees of the subcooling value shown in the installation
instructions.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 10 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 5 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
NOTE: Pressures are measures at the liquid and suction service valve ports.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAMS
ASX140[18-60]1*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Y L N O R O T C A N T C E O L O P
E L U B D E O T A R E N T L A
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
ASX140[18-36/48]1C[A/B]
ASX140421D[A/B] / ASX140[48-60]1[BA/B]
WIRING DIAGRAMS
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Y L N R O O T C A N T C E O L O P
E L U B D E O T
R E N T A L A
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
ASX140[24-36]1CC / ASX140421DC
ASX140481CB / ASX140601BC / ASX1401801D*
WIRING DIAGRAMS
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Y L N O R T O C A N T C E O L P O
L E B U O E T D A N R E T A L
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
|
AEG Oven B3040 1 User Manual
Air King Fan 4TM65A 9530A User Manual
Aiwa Car Stereo System ADC M60 User Manual
Amana Microwave Oven AMC5143AAB User Manual
Amcor Electric Heater AMH9 User Manual
AOSafety Respiratory Product Respirator Fit Testing Kits and Accessories User Manual
Atlona TV Converter Box AT AD2 User Manual
Beckett Water Gardening Plumbing Product W600 User Manual
Behringer Music Mixer AUTOCOM PRO XL MDX1600 User Manual
BK Car Amplifier AVP 4090 User Manual