| Alcatel Carrier Internetworking Solutions Paint Sprayer ACT 250 User Manual | 
| Contents   ACT 250 addendum   Commissioning   (continued)   I RS 232/485 serial link . . . . . . . . . . . . . . I p. 14   I Wiring the RS 232 or RS 485   serial link   I Configuring the RS 232 or RS 485   serial link   I Use   I Detailed description of RS commands. . . . . . I p. 15   I Syntax conventions applicable to   all commands   Use   I Controlling the pump from the   ACT 250 controller . . . . . . . . . . . . . . . . . I p. 24   I Controller functions. . . . . . . . . . . . . . . . . I p. 26   I Precautions   I Operation in local mode   I Fault management   Alcatel Vacuum Technology France - ACT 250 addendum   2 Download from Www.Somanuals.com. All Manuals Search And Download.   Presentation   The ACT 250 controller   Dear Customer,   You have just bought an   ACT 250 controller. In   order to ensure the best   possible performance of the   equipment and your   complete satisfaction in   using it, we advise you to   read this addendum   carefully before attempting   to service or use your   controller.   Insertable “box” version   Part No. 108320   Integrable “OEM” version   Part No. 108151   This controller drives ATP 150 or ATP 400 pumps,   providing their power supply and enabling remote control.   ACT 250 controller   The ACT 250 controller is available as:   I an insertable “box” version with case,   I an integrable “OEM” version without case.   This version can replace the “box” version when   integrating the pump in a complex installation or device.   Main characteristics   I Dry contact signal outputs   I Opto-isolated control inputs   I RS 232 / 485 serial links   I Operate at all voltages from 85 to 265 V, 50/60 Hz   The ACT 250 controller is a new product, not described in Edition 09 of the ATP Series   Pump User Manual.   This addendum provides the additional information needed to use the controller.   Alcatel Vacuum Technology France - ACT 250 addendum   3 Download from Www.Somanuals.com. All Manuals Search And Download.   Presentation   Accessories   Pump power supply   cable   The controller is connected to the pump using a   corresponding power supply cable, ordered separately.   Cable length (m)   1 Part No.   105086   A458885   101812   101810   101811   105303   A458478   1.5   3.5   5 10   15   20   “End-user” kit   This kit, ordered separately, is needed to use the ACT in   local mode. It includes:   I 1 mains cable,   I 1 connector plug,   I 4 legs.   Kit   Part No.   108935   108936   108948   USA   Europe   UK   Alcatel Vacuum Technology France - ACT 250 addendum   4 Download from Www.Somanuals.com. All Manuals Search And Download.   Presentation   ACT 250 “box” controller   control modes   There are two possible control modes:   local control and remote control.   Local control mode   Pump start-up switch   Pump stop switch   START   STOP   POWER   FAULT   SPEED   Controller power and fault   indicators   Pump status indicators   A C T 2 5 0   There are three possible remote control modes:   Remote control   1 The remote control   Established by the REMOTE   connector which:   2 - provides remote control of   the START, STOP, STANDBY,   EXTERNAL SAFETY and   MODE SELECT functions;   1 - replicate the available   monitoring parameters   (At speed / Starting / Fault)   on dry contacts.   2 2 RS 232 serial link The RS232 serial link is used to control and monitor the   pump using a computer.   RS 485 serial link The RS485 serial link is used to connect several pumps in   a network.   The wiring characteristics are given on page 13   Alcatel Vacuum Technology France - ACT 250 addendum   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Presentation   ACT 250 “OEM” controller   control modes   There are two possible control modes:   local control and remote control.   Local control mode   Pump start-up switch   Pump stop switch   Controller power and fault   indicators   Pump status indicators   Remote control   There are three possible remote control modes:   Established by the REMOTE   connector which:   1 The remote control   - provides remote control of   the START, STOP, STANDBY,   EXTERNAL SAFETY and   2 1 MODE SELECT functions;   - replicate the available   monitoring parameters   (At speed / Starting / Fault)   on dry contacts.   The RS232 serial link is used to control and monitor the   2 2 RS 232 serial link   RS 485 serial link   pump using a computer.   The RS485 serial link is used to connect several pumps in   a network.   The wiring characteristics are given on page 13   Alcatel Vacuum Technology France - ACT 250 addendum   6 Download from Www.Somanuals.com. All Manuals Search And Download.   Presentation   ACT 250 controller   technical characteristics   Characteristic   Weight   Unit   kg   ACT 250 “box”   1.8   ACT 250 “OEM”   1.3   Dimensions H x W x D   mm   128.4 × 106.3 × 220   3U × 1/4 Rack   95 × 100 × 212   Nominal voltage   Frequency   Maximum power   Maximum ambient   temperature   Storage temperature   Customer mains   circuit breaker rating   V Hz   W 85 - 265   50/60   300   ° C   ° C   A T ≤ 50   –15/+70   T10A   220   ACT 250 “box”   dimensions   (in mm)   106,3   91,4   105   250   60Hz   PUMP   POWER FAULT   SPEED   ACT 250   Alcatel Vacuum Technology France - ACT 250 addendum   7 Download from Www.Somanuals.com. All Manuals Search And Download.   Presentation   ACT 250 controller   technical characteristics   ACT 250 “OEM”   dimensions   (in mm)   RS232/485   POWER SUPPLY   REMOTE   PUMP   L1   T 4 tr Ø 3,2   L2   18,67   153,1   Attached using four M3 screws or mounted in an Alcatel   cabinet   Alcatel Vacuum Technology France - ACT 250 addendum   8 Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Safety instructions   Before switching on the controller, the user should   study the manual and follow the safety   instructions listed in the compliance certificate   booklet supplied with the pump.   See sheet B10 in the ATP pump User Manual.   Alcatel Vacuum Technology France - ACT 250 addendum   9 Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   ACT 250 controller   electrical connections   I If the controller is remote controlled, make the various   connections on the REMOTE connector (see page 13 for   wiring details).   I If the controller is used in local mode, the   pump can only operate if the connector plug   (ordered separately) is connected to the REMOTE   connector (see page 13 for wiring details).   ATP 150   or ATP 400   pump   PC   Connect the RS232/485 serial link   cable to the connector (cable and PC   supplied by customer)   RS configuration   Connect the   fan   (air-cooled   ATP)   Remote cable   or   Connector plug   (standard   wiring) to use   the unit in local   mode.   Connect the controller to   the pump using the cable   (ordered separately)   Connect the controller to the mains   (cable ordered separately).   An earth connection must be provided.   Alcatel Vacuum Technology France - ACT 250 addendum   10   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   ACT 250 remote connector   characteristics   When units containing the control circuits are   equipped with dry contact outputs, it is the   customer's responsibility to use the outputs in   compliance with safety regulations.   The inputs are activated when   Voltage control mode   6 11   12   13   14   15   1 + + + + – an AC or DC voltage is   applied. The voltage should be   between 15 and 24 Volts.   (15-pin Sub-D female   connector).   10   5 Cable supplied   by customer   +15 V   0 V   Inactive = the external safety device is activated   (e.g. an emergency stop)   Active = pump operation authorised   Principle of voltage-   controlled optocoupled   inputs   Ext. safety   11   Select “status” or “pulse” command mode. This   affects the START/STOP and STANDBY commands.   Select Mode   12   I 12 - inactive = “status” mode   Example : Ext. safety activated   Start   Start   Stop   Stop   Ex. pin 14   Ex. pin 13   6 11   12   13   1 standby   standby   nominal   speed   nominal   speed   I 12 - active = “pulse” mode   14   15   10   Stop   Start   Stop   Start   Ex. pin 14   Ex. pin 13   5 nominal   speed   nominal   speed   standby   standby   O V   Inactive = operation at nominal speed   Active = operation at reduced speed   +15 V   Standby Mode   13   External contact   supplied by customer   Inactive = Stop   Active = Start   Start/Stop   14   Common for inputs   15   Alcatel Vacuum Technology France - ACT 250 addendum   11   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   ACT 250 remote connector   characteristics   Signalling on output   contacts   These are dry contacts (48 V AC - 1 A) which replicate   pump status information.   6 7 8 9 1 2 3 4 When the output contact is closed:   1 - 6   2 - 7   3 - 8   4 - 9   The pump has reached the selected speed   The pump is accelerating   No fault signal   Not used   Alcatel Vacuum Technology France - ACT 250 addendum   12   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   ACT 250 remote connector   wiring   I Standard connector plug (factory wired)   Use in local mode   6 11   12   1 Wiring seen from solder side   10   15   5 Use in remote control I With galvanic isolation (recommended)   mode   Wiring seen from solder side.   compulsory screen   customer   device   6 15 V –> 24 V   11   12   13   14   15   1 I Ext. safety   I Select. Mode   I Standby Mode   I Start/Stop   10   5 I Common for   inputs   ACT unit   ground   device ground   I Without galvanic isolation (not recommended)   Wiring seen from solder side.   compulsory screen   customer   device   6 11   12   13   14   15   1 I Ext. safety   I Select. Mode   I Standby Mode   I Start/Stop   10   5 ACT unit   ground   device ground   The voltage used to power the contacts is supplied by the   ACT 250 (terminal 5). The disadvantage of this method is   the risk of exposing this voltage to external interference   (see also diagrams on page 11 ).   Alcatel Vacuum Technology France - ACT 250 addendum   13   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   RS 232 / 485 serial link   Wiring the RS 232 or   RS 485 serial link   See sheet B 110 in the ATP Series Pump User Manual.   Configuring the RS 232   The link is configured using switches on the rear panel of   the controller.   or RS 485 serial link   0 1   Switch   description   parity type   parity   baud rate   RS type   0 odd   no   1 even   yes   1 2 3 4 9600   RS 485 RS 232   4800   Factory configuration: 9600 baud, NO parity, RS 232   See the detailed list of commands on page 15   Use   Alcatel Vacuum Technology France - ACT 250 addendum   14   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   adr = address, from 000 to 255   <CR> Carriage Return (ascii 13)   <LF> Line Feed (ascii 10); shown in brackets as it is not   compulsory.   Syntax conventions   applicable to all   commands   Status values   ok : command executed correctly   Err0 : adjustment error (out of bounds)   Err1 : command error (syntax)   Err2 : parameter error (e.g. non-hexadecimal character)   Err3 : context error   Error messages   Err4 : checksum error   Specifies the address of the device for networking   #adrADRaaa<CR>[<LF>]   ADR   Syntax   adr   = address of device before this command   = new address of device   aaa   condition   : 000 ≤ aaa ≤ 255   Result   #aaa,ok or Err2   This command is used to allocate a specific number to each device   on the network   (loop for RS232 or parallel for RS485).   Note: it is important to note the number allocated to   each device.   Alcatel Vacuum Technology France - ACT 250 addendum   15   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   CKS Enables or disables checksums on reply strings   Syntax #adrCKSON<CR>[<LF>]   Enables the ASCII checksum character at the end of a   reply string   or   #adrCKSOFF<CR>[<LF>]   Disables the ASCII checksum character at the end of a   reply string   Result #adr,ok,S   for CKSON   for CKSOFF   #adr,ok   This feature enables the user to test whether a transmission error has   occurred for the reply string.   S is a character whose ASCII value is the 7-bit checksum of all ASCII   character values from the start of the reply string to the character   preceding the S. The 8th bit of S (most significant bit) is always 1.   CYC Starts the specified running-in cycle   Syntax #adrCYC1<CR>[<LF>] to start running-in program 1,   or   #adrCYC2<CR>[<LF>] to start running-in program 2   Result #adr,ok   Running-in program 1 should be executed after a pump maintenance   operation (change of bearings).   At the end of the program, the pump maintenance parameters are   updated and the “maintenance requested” alert can be cleared.   Program 2 is used after regreasing (ATP series only), or after   prolonged storage (ATH 20/40 only).   Alcatel Vacuum Technology France - ACT 250 addendum   16   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   DLI Defines the DataLogger transmission interval   Syntax   #adrDLIxxx<CR>[<LF>]   xxx: DataLogger transmission interval in seconds   condition: 001 ≤ xxx ≤ 255   Result   #adr,ok or Err2   See also: DLR   Note: if ok, the interval sent is stored in user memory.   DLR   Syntax   Result   Enables DataLogger operation (RS232 only)   #adrDLR<CR>[<LF>]   #adr,sssss,nnnnn,iiii,ttttt,uuuu.o,www,ppp,vvv   Returns current values   : sssss : current speed (rpm)   nnnnn : speed set point (rpm)   iiii   ttttt   : current value (mA)   : pump operating time (hours)   uuuu.o: (reserved)   www : pwm (reserved)   ppp : pump temperature (°C)   vvv   : variator temperature (°C)   The main characteristics of the pump and its controller are sent over   the RS link, at the rate defined by the DLI command.   See also: DLI, LNG, SEP, SHT   Note: any new characters arriving on the serial port (RS 232) will   cancel the automatic DataLogger transmission.   Alcatel Vacuum Technology France - ACT 250 addendum   17   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   ECH Enables or disables command echoing   Syntax   #adrECHON<CR>[<LF>]   enables all characters received to be echoed over the serial port   or   #adrECHOFF<CR>[<LF>]   disables characters received from being echoed over the serial port.   Result   #adr,ok   Comments:   - This command is disabled in RS 485 operation, the value OFF   is required.   - Using a loop-type RS 232 network requires “ECHON”.   HDR Defines the start character for a command reply string   Syntax #adrHDRnnn<CR>[<LF>]   nnn: 3-digit decimal value of the ascii code of the   corresponding character (with leading zeros).   condition : 020 •nnn •255   Result ?adr,ok   ? is the desired character.   if error   #adr,ErrX   Allows the user to distinguish between the first character in a “command” string   (for which # cannot be changed) and the first character of a “reply” string.   Affects the first character of all replies.   Default value: the hash sign, # (ascii code = 035)   If ok, the selected value is automatically stored in user memory.   IDN   Identifies the device which is communicating, and its   software version   Syntax   Result   #adrIDN<CR>[<LF>]   #adr, VS.... - Vx.zz’   or   #adr, VS.... - Vx.zz for “Alcatel pump type”   Returns the type of Variator Supervisor, the software version (x), the   software edition (zz), and the type of pump for which this variator is   set up.   Alcatel Vacuum Technology France - ACT 250 addendum   18   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   LEV   Syntax   Result   Returns the state of the parameters defined by SET   #adrLEV<CR>[<LF>]   #adr,nnnnn,sssss,aaaa,hhhhh or   #adr,nnnnn rpm,sssss rpm,aaaa mA,hhhhh hours   Returns the current values:   nnnnn : speed set point   sssss : stand-by speed   aaaa : max. current set point   hhhhh : alert level for pump bearing maintenance   LNG   Syntax   Result   Returns the strings sent with the identification sub-strings   #adrLNG<CR>[<LF>]   #adr,ok   AVT>   Allows the parameters returned by the DLR, LEV and SPD commands   to be identified with sub-strings. DLR, LEV, SPD.   Also generates the “AVT>” prompt each time a <CR> character is   received.   See also: SHT   NSP   Syntax   Result   Switches the speed set point to the nominal speed value   #adrNSP<CR>[<LF>]   #adr,ok   The speed set point for the pump is set to its nominal value.   This configuration is automatically saved in user memory.   This mode of operation prevents the use of the “RPM” command.   See also: RPM, SBY   Alcatel Vacuum Technology France - ACT 250 addendum   19   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   OPT   Used to select possible user choices   Syntax   #adrOPT2 n<CR>[<LF>]   choice of temperature unit:   n = 0 : degrees Centigrade   n = 1 : degrees Fahrenheit   Result   #adr,ok   Comment: The choice of the temperature unit affects   the results of the DLR and STA strings.   See also: SEL   RPM   Syntax   Result   Defines the speed set point in stand-by mode   #adrRPM nnnnn<CR>[<LF>] or #adrRPMnnnnn<CR>[<LF>]   #adr,ok or #adr,ErrX   X = 1, out of range; 2, parameters ; 3, context (not in Stand-by mode)   Comment: if ok, the new speed is automatically stored in user   memory.   See also: NSP, SBY   SAV Saves the internal parameters in user memory   Syntax #adrSAV<CR>[<LF>]   Result #adr,ok   Saves the current context (except for running-in cycles). If this   command is sent when the pump is powered up, it can for example   allow automatic re-start in the event of a power cut.   Alcatel Vacuum Technology France - ACT 250 addendum   20   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   SBY   Syntax   Result   Switches the speed set point to the stand-by value   #adrSBY<CR>[<LF>]   #adr,ok   Resets the stand-by speed to its last stored value, and allows it to be   modified if an “RPM” command is sent.   This configuration is automatically stored in user memory.   See also: NSP, RPM   SEL Returns the state of the parameters defined by OPT   Syntax #adrSEL<CR>[<LF>]   Result #adr,a,u   a: Reserved   u: Returns the choice of temperature unit::   u = 0: degrees Centigrade   u = 1: degrees Fahrenheit   SEP Defines the character which separates the parameters   in a reply   Syntax #adrSEPnnn<CR>[<LF>]   3-digit decimal value of the ASCII code of the desired char-   acter (with leading zeros if necessary).   condition: 000 ≤ nnn ≤ 255   Result #adr,ok or #adr,ErrX if error   Allows the user to select the character which separates   the parameters returned by the DLR, STA and LEV   commands. Default value: comma “,” ASCII code = 044   If ok, the selected value is automatically stored in user memory.   Alcatel Vacuum Technology France - ACT 250 addendum   21   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   SET Defines the internal operating parameters   Syntax #adrSET1 hhhhh<CR>[<LF>] : maintenance time limit   000<hhhhh<65535   Result #adr,ok or #adr,ErrX   See also: LEV   Return the DataLogger string without the identification   sub-string   SHT   #adrSHT<CR>[<LF>]   Syntax   Result   #adr,ok   The strings sent following DLR, LEV and SPD commands are sent   without parameter identification sub-strings (e.g. without units).   See also: LNG   SPD Returns the current speed   Syntax #adrSPD<CR>[<LF>]   Result #adr,nnnnn   See also: LNG, SHT #adr,nnnnn rpm   Alcatel Vacuum Technology France - ACT 250 addendum   22   Download from Www.Somanuals.com. All Manuals Search And Download.   Commissioning   Detailed description of RS commands   Returns the status of the internal dynamic parameters   #adrSTA<CR>[<LF>]   STA   Syntax   Result   #adr,xxxxxx,yyyyyy,zzzzzz,sssss,iiii,www,ppp,vvv,ttttt<CR><LF>   adr: address   543210   xxxxxx   status bits:   yyyyyy fault bits:   5 - variator temperature   4 - motor temperature   3 - excess current   2 - sensors or start-up   1 - external   5 - RS echo (1->off)   4 - String long (0) / short (1)   3 - On (1) / Off (0)   2 - reduced or nominal   speed reached(1)   1 - standby (1)   0 - pump not connected   0 - running-in (1)   zzzzzz alert bits:   sssss current speed value in rpm   iiii current value in mA   www reserved (pwm value)   ppp pump temperature value   vvv variator temperature   5 - reserved (future use)   4 - reserved (future use)   3 - variator temperature   2 - motor temperature   1 - start-up time exceeded (future)   0 - operating time exceeded   ttttt pump operating time value   Reminder: The “#” character at the start of the reply   string can be set with the “HDR” command.   The “,” character which separates the parameters in   the reply string can be modified with the “SEP”   command.   Defines the turbomolecular pump operating state   TMP   #adrTMPON<CR>[<LF>]: start pump rotation   #adrTMPOFF<CR>[<LF>]: stop pump   Syntax   #adr,ok or #adr,Err3   if the pump is already in the state   requested (context error)   Result   Alcatel Vacuum Technology France - ACT 250 addendum   23   Download from Www.Somanuals.com. All Manuals Search And Download.   Use   Controlling the pump from the ACT 250   controller   Once all connections are complete, plug the controller into   the mains.   Indicator lights   “box” version   START   STOP   POWER   FAULT   SPEED   A C T 2 5 0   Yellow lit   Controller on   Red lit   Yellow lit   pump rotation   speed accelerating greater than the selected   speed (speed reduction during   operation)   Green flashing   The pump rotation speed is   Controller fault   Red flashing   Controller alert   Green lit   The pump has attained the   selected speed.   “OEM” version   Alcatel Vacuum Technology France - ACT 250 addendum   24   Download from Www.Somanuals.com. All Manuals Search And Download.   Use   Controlling the pump from the ACT 250   controller   Starting the pump with   the START switch   The pump is started up to reach the selected speed. The   yellow rising speed indicator light comes on. When the   pump reaches its selected speed, the yellow indicator light   goes off and the green indicator light comes on.   START   Stopping the pump with   the STOP switch   The rotation speed monitoring indicator lights go off.   The pump motor is no longer powered, the pump   decelerates.   STOP   Alcatel Vacuum Technology France - ACT 250 addendum   25   Download from Www.Somanuals.com. All Manuals Search And Download.   Use   Controller functions   Precautions   The “OEM” version of the ACT 250 has been   designed with electrical safety and   electromagnetic compatibility standards in mind.   It is the user’s responsibility to provide external shielding   to comply with EMC and electrical safety standards.   Local mode operation   The Start and Stop functions use switches located on the   front panel of the “box” version and on the board for the   “OEM” version.   START   STOP   POWER   FAULT   SPEED   The pump’s operating status is shown by the state of the   “POWER” indicator (yellow) and the three “FAULT” (red)   and “SPEED” (yellow and green) indicators.   Press button   START STOP   State of indicators   Power Fault Speed   Indication of rotation   during operation   (controller on)   Pump   rotation   speed   Pump   motor on   Yellow Red Yellow Green   0 0 NO   YES   0 1 2 Before start-up   < selected   speed   1 0 0 0 During start-up   = selected   speed   YES   3 4 Pump at nominal speed   ≤ selected   speed   YES   NO   Alert or fault   triggered   (see page 27 )   Alert   Fault   0 0 0 0 < selected   speed   0 0 YES   5 Overload   > selected   speed   0 1 YES   NO   6 7 Speed set point lowered   Pumping stopped   0 0 indicator off   indicator on   indicator flashing   Alcatel Vacuum Technology France - ACT 250 addendum   26   Download from Www.Somanuals.com. All Manuals Search And Download.   Use   Controller functions   Fault monitoring   I Alerts are indicated by:   - flashing red indicator. The pump power supply is   maintained.   I Faults are indicated by:   - lit red indicator. The pump is stopped as soon as a fault   is detected.   Alerts and faults shown by the indicator light include:   - controller overheating,   - pump motor overheating,   - cable disconnected (pump / controller)   - external safety device open,   - overcurrent on speed variator.   Alerts and faults can be identified using the serial link (see   page 23, STA command).   Alcatel Vacuum Technology France - ACT 250 addendum   27   Download from Www.Somanuals.com. All Manuals Search And Download.   France   Alcatel Vacuum Technology - France   98, avenue de Brogny - BP 2069   74009 ANNECY - Cedex   Tel : (33) 4 50 65 77 77   Fax : (33) 4 50 65 77 89   Germany   Alcatel Hochvakuum Technik GmbH   Am Kreuzeck 10   D – 97877 WERTHEIM   Tel: (49) 9342 96100   Fax: (49) 9342 961030   Italy   Alcatel Vacuum Systems S.p.A   Via Trento, 30   20059 VIMERCATE (MI)   Tel : (39) 039 686 3855   Fax : (39) 039 667 125   Japan   Alcatel Japan LTD   13 fl. Dai Tokyo - Kasai Shinjuku bldg   3 - 25 - 3 - Yoyogi, Shibuya - ku   TOKYO 1510053 - JAPAN   Tel : (81) 3 5302 4350   Fax : (81) 3 5302 4332   Korea   Alcatel Vacuum Technology Korea   5th Floor, Sunghyun B/D   10-5, Karak-Dong, Songpa-Ku   Seoul - SOUTH KOREA   Tel : (82) 2 409 6277   Fax : (82) 2 409 6279   United Kingdom   Alcatel Vacuum Technology UK Ltd   8 Bain Square   Kirkton Campus   Livingstone - WEST LOTHIAN   EH - 547 DQ - SCOTLAND   United Kingdom   Tel. (44) 1 506 418 000   Fax. (44) 1 506 418 002   USA   Alcatel Vacuum Products   67 Sharp Street   HINGHAM, MA. 02043   USA   Tel :1(781) 331 4200   Fax :1(781) 331 4230   Alcatel Vacuum Technology - France - 98, avenue de Brogny - BP 2069 - 74009 ANNECY Cedex France   Tel. (33) 4 50 65 77 77 - Fax (33) 4 50 65 77 89 - Telex 385 153 F   Download from Www.Somanuals.com. All Manuals Search And Download.   |