View
ADDER
GEM
4 Port ADDERView GEMAV4GEM
2 Port ADDERView GEMAV2GEM
Remote Control Pad/Display RC1
w
e
i
V
www.addertec.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Alternative language versions of this
manual may be downloaded from:
w w w .a d d e rt e c .c o m
Quick Ins tallation and Operation Guide
QUICK INSTALLATION
Power off all your computers and connect them to the ORANGE ports on the rear
of the AdderView GEM. Adder 3-in-1 keyboard/video/mouse combination cables
are recommended for convenience. Suitable individual standard keyboard, video
and mouse cables are also widely available.
Connect your keyboard, monitor and mouse to the GREY port on the rear of the
AdderView.
OPERATION GUIDE SUMMARY
The AdderView's default configuration is suitable for most systems.
A computer may be selected using the front panel key, a three button mouse or a
keyboard hotkey combination. To select a computer using the mouse press and
release the left or right hand buttons whilst holding down the central button. To
select a computer using the keyboard hotkeys hold down the CTRL and ALT
keys, press and release the required port key (e.g. 1) and then release the CTRL
and ALT keys.
Safety information
For use in dry, oil free indoor environments only.
Do not attempt to service the AdderView GEM yourself.
Follow all warnings and instructions marked on the AdderView GEM, its optional
power adapter and its accessories.
Warning - live parts contained within optional power adapter.
No user serviceable parts within optional power adapter - do not dismantle.
Replace the optional power adapter with a manufacturer approved type only.
If you use a power extension cord with the AdderView GEM, make sure the total
ampere rating of the devices plugged into the extension cord does not exceed the
cord’s ampere rating. Also, make sure that the total ampere rating of all the
devices plugged into the wall outlet does not exceed the wall outlet’s ampere
rating.
AdderView GEM
ENGLISH
Download from Www.Somanuals.com. All Manuals Search And Download.
Komplette Handbuchvers ion Deuts che is t herunterladbar von:
w w w .a d d e rt e c .c o m
Quick-Guide für Ins tallation & Betrieb
QUICK-INSTALLATION
Schalten Sie alle Ihre Computer aus, und schließen Sie sie an die ORANGEFARBENEN
Ports auf der Rückseite des AdderView GEM an. Wir empfehlen der Einfachheit halber
die Verwendung der Adder 3-in-1 Tastatur/Video/Mauskabel, es sind in der Regel jedoch
auch geeignete einzelne Standardmaus-, Video- und Tastaturkabel überall im Handel
erhältlich.
Schließen Sie Ihre Tastatur, Monitor und Maus an den GRAUEN Port auf der Rückseite
des AdderView an.
ZUSAMMENFASSUNG DES BETRIEBS-GUIDES
Die Vorgabekonfiguration des AdderView ist für die meisten Systeme geeignet.
Ein Computer kann für entweder die Verwendung der Taste auf der Frontanzeige, einer
Maus mit drei Tasten oder einer Kombination der Hot-Keys der Tastatur ausgewählt
werden. Zur Auswahl eines Computers, der eine Maus verwendet, die linke oder rechte
Taste kurz drücken, während die mittlere Taste gedrückt gehalten wird. Um einen
Computer auszuwählen, der die Hot-Keys der Tastatur verwendet, die Strg und ALT
Tasten zusammen gedrückt halten, und die erforderliche Port-Taste (z.B. 1) drücken und
loslassen, und dann die Strg und ALT Tasten loslassen.
Sicherheits technis che Informationen
Nur für den Gebrauch innerhalb von trockenen, ölfreien Räumen vorgesehen.
Die Wartung des AdderView GEM darf nur ausschließlich von dazu qualifiziertem
Fachpersonal vorgenommen werden.
Sämtliche Warnhinweise und Anweisungen auf dem AdderView GEM, seinem optionalen
Stromadapter und Zubehörteilen beachten und befolgen.
Warnung – im Stormadapter sind unter Spannung stehende Teile enthalten.
Keine vom Benutzer zu wartenden Teile im optionalen Stromadapter enthalten – nicht
auseinandernehmen.
Den optionalen Stromadapter nur durch einen vom Hersteller zugelassenen Typ
ersetzen.
Bei Verwendung eines Stromverlängerungskabels für den AdderView GEM, muss darauf
geachtet werden, dass die Gesamtamperezahl der an dieses Kabel angeschlossenen
Geräte nicht den Amperenennwert des Kabels übersteigt. Auch darauf achten, dass die
Gesamtamperezahl aller an die Steckdose angeschlossenen Geräte nicht den
Amperenennwert der Steckdose überschreitet.
AdderView GEM
GERMAN
Download from Www.Somanuals.com. All Manuals Search And Download.
Guía rápida de ins talación y funcionamiento
INSTALACIÓN RÁPIDA
Desconecte todos los ordenadores y conéctelos a los puertos NARANJA en la parte
posterior del AdderView GEM. Para mayor comodidad se recomiendan cables
combinados 3-en-1 teclado/vídeo/ratón. También están ampliamente disponibles cables
individuales normales adecuados para el teclado, el vídeo y el ratón.
Conecte el teclado, el monitor y el ratón al puerto GRIS en la parte posterior del
AdderView.
RESUMEN DE LA GUÍA DE FUNCIONAMIENTO
La configuración por defecto del AdderView es adecuada para la mayoría de los
sistemas.
Puede seleccionarse un ordenador utilizando la tecla del panel frontal, un ratón de tres
botones o una combinación de teclas rápidas en el teclado. Para seleccionar un
ordenador utilizando el ratón, pulse y suelte los botones izquierdo o derecho mientras
mantiene pulsado el botón del medio. Para seleccionar un ordenador utilizando las teclas
rápidas del teclado, mantenga pulsadas las teclas CTRL y ALT, pulse y suelte la tecla del
puerto requerida (p.e. 1) y a continuación suelte las teclas CTRL y ALT.
Información s obre s eguridad
Solamente debe usarse en interiores, en entornos secos y sin grasa.
No intente realizar ningún tipo de mantenimiento al AdderView GEM usted mismo.
Siga todos los avisos e instrucciones marcadas en el AdderView GEM, el adaptador de
potencia opcional y todos sus accesorios.
Aviso – el adaptador de potencia opcional tiene piezas con tensión.
El adaptador de potencia opcional no contiene piezas que pueda mantener el usuario –
no desmontarlo.
Cambie el adaptador de potencia opcional solamente con un tipo aprobado por el
fabricante.
Si utiliza una cable de extensión con el AdderView GEM, compruebe que el amperaje
nominal total de los equipos enchufados en el cable de extensión no superen el amperaje
nominal del cable de extensión. Asimismo, compruebe que el amperaje nominal total de
todos los equipos conectados a la toma de red no superen el amperaje nominal de la
toma.
AdderView GEM
SPANISH
Download from Www.Somanuals.com. All Manuals Search And Download.
Téléchargez une vers ion Français complète de ce manuel :
w w w .a d d e rt e c .c o m
Guide d'ins tallation rapide et mode d'emploi
INSTALLATION RAPIDE
Mettez tous vos ordinateurs hors tension et raccordez-les aux ports ORANGE à l'arrière
d'AdderView GEM. Les câbles clavier/vidéo/souris Adder 3-in-1 sont recommandés pour
des raisons pratiques. Des câbles clavier, vidéo et souris standard se trouvent également
facilement sur le marché.
Raccordez votre clavier, moniteur et souris au port GRIS à l'arrière de l'AdderView.
MODE D'EMPLOI SOMMAIRE
La configuration par défaut de l'AdderView convient à la plupart des systèmes.
Pour sélectionner un ordinateur, utilisez la touche du panneau avant, une souris à trois
boutons ou une combinaison de touches de raccourci clavier. Pour sélectionner un
ordinateur à l'aide de la souris, maintenez la pression sur le bouton central et appuyez
sur le bouton gauche ou droite avant de relâcher. Pour sélectionner un ordinateur avec
les touches de raccourci clavier, maintenez les touches CTRL et ALT enfoncées,
appuyez sur la touche du port souhaité (ex. 1) et relâchez, puis relâchez les touches
CTRL et ALT.
Cons ignes de s écurité
A n'utiliser qu'à l'intérieur, dans un environnement sec et exempt d'huile.
Ne pas assurer soi-même l'entretien de l'AdderView GEM.
Observer tous les avertissements et instructions marqués sur l'AdderView GEM, son
adaptateur de courant optionnel et ses accessoires.
Avertissement – l'adaptateur de courant optionnel renferme des pièces sous tension.
L'adaptateur de courant optionnel ne contient aucune pièce devant être révisée par
l'utilisateur – ne pas le démonter.
Ne remplacer l'adaptateur de courant optionnel que par un adaptateur approuvé par le
fabricant.
Lorsqu'une rallonge est utilisée pour l'AdderView GEM, vérifier que l'intensité nominale
totale des périphériques branchés sur la rallonge ne dépasse pas l'intensité nominale du
câble. Par ailleurs, vérifier que l'intensité nominale totale de tous les périphériques
branchés sur la prise murale ne dépasse pas l'intensité nominale de la prise murale elle-
même.
AdderView GEM
FRENCH
Download from Www.Somanuals.com. All Manuals Search And Download.
Guida di ins tallazione rapida e funzionamento
INSTALLAZIONE RAPIDA
Spegnere tutti i computer e collegarli alle porte ARANCIONI sul retro
dell’AdderView GEM. Per facilità consigliamo i cavi Adder combinati 3-in-1
tastiera/video/mouse. Sono pure disponibili cavi mouse, video e tastiera standard
individuali adatti.
Collegare la tastiera, monitor e mouse alla porta GRIGIA sul retro dell’AdderView.
SOMMARIO GUIDA OPERATIVA
La configurazione di default dell’AdderView è adatta alla maggior parte dei
sistemi.
Si può selezionare un computer usando il tasto sul pannello frontale, un mouse a
tre bottoni o una tastiera con tasti attivi. Per selezionare un computer con il
mouse, premere e rilasciare i bottoni sinistro o destro trattenendo
contemporaneamente quello centrale. Per selezionare un computer con tasti attivi
tastiera, tener premuti i tasti CTRL e ALT, premere e rilasciare il tasto porta
richiesta (es. 1) e quindi rilasciare i tasti CTRL e ALT.
Informazionoi riguardanti la s icurezza
Da usare esclusivamente in interni asciutti e privi di olio.
Non cercare di effettuare manutenzione sull’AdderView GEM.
Seguire tutti gli avvertimenti ed istruzioni presenti sull’AdderView GEM, sull’adattatore
opzionale di potenza e sugli accessori.
Attenzione – l’adattatore opzionale di potenza contiene parti sotto tensione.
L’adattatore opzionale di potenza non contiene parti soggette a manutenzione da parte
dell’utente – non smontarlo.
Sostituire l’adattatore opzionale di potenza solo con uno di tipo approvato dal produttore.
Se si usa una prolunga con l’AdderView GEM, controllare che la potenza nominale totale
in ampère dei dispositivi collegati alla prolunga non superi la potenza nominale in ampère
della prolunga stessa. Controllare inoltre che la potenza nominale totale in ampère dei
dispositivi collegati non superi la potenza nominale in ampère della presa a muro.
AdderView GEM
ITALIAN
Download from Www.Somanuals.com. All Manuals Search And Download.
AdderView GEM
Download from Www.Somanuals.com. All Manuals Search And Download.
About this manual
AdderView GEM - Installation and Use
Third edition (June 2001)
(c) 2001 Adder Technology Ltd.
Part No. ADD0037/3
All rights reserved. Whilst every precaution has been taken in the preparation of this
manual, Adder Technology Ltd assumes no responsibility for errors or omissions.
Neither is any liability assumed for damages resulting from the use of the information
contained herein. We reserve the right to change the specifications, functions and
circuitry of the product without notice. All trademarks acknowledged.
Safety information
For use in dry, oil free indoor environments only.
Do not attempt to service the AdderView GEM yourself.
Follow all warnings and instructions marked on the AdderView GEM, its optional
power adapter and its accessories.
Warning - live parts contained within optional power adapter.
No user serviceable parts within optional power adapter - do not dismantle.
Replace the optional power adapter with a manufacturer approved type only.
If you use a power extension cord with the AdderView GEM, make sure the total
ampere rating of the devices plugged into the extension cord does not exceed
the cord’s ampere rating. Also, make sure that the total ampere rating of all the
devices plugged into the wall outlet does not exceed the wall outlet’s ampere
rating.
AdderView GEM
Ins tallation and Us e
Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
Adder Technology Ltd warrants that this product shall be free from defects in
workmanship and materials for a period of one year from the date of original
purchase. If the product should fail to operate correctly in normal use during the
warranty period, Adder will replace or repair it free of charge. No liability can be
accepted for damage due to misuse or circumstances outside Adder’s control. Also
Adder will not be responsible for any loss, damage or injury arising directly or
indirectly from the use of this product. Adder’s total liability under the terms of this
warranty shall in all circumstances be limited to the replacement value of this
product.
If any difficulty is experienced in the installation or use of this product that you are
unable to resolve, please contact your supplier.
Trademarks
All trademarks mentioned in this manual are acknowledged to be the property of the
respective trademark owners.
Adder is a registered trademark of Adder Technology Limited.
Compaq is a registered trademark of Compaq Computer Corporation.
Hewlett-Packard is a registered trademark of Hewlett-Packard.
IBM, PC/AT, PS/2, RS/6000 and ThinkPad are registered trademarks of
International Business Machines Corporation.
Logitech, MouseMan+ and Pilot Mouse+ are trademarks of Logitech Inc.
Microsoft and Windows are registered trademarks, and IntelliMouse is a trademark
of Microsoft Corporation.
Velcro is a trademark of Velcro USA Inc.
AdderView GEM
Ins tallation and Us e
Page 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Radio Frequency Energy
Shielded cables must be used with this equipment to maintain compliance with radio
frequency energy emission regulations and ensure a suitably high level of immunity
to electromagnetic disturbances.
European EMC directive 89/336/EEC
FCC Compliance Statement (United States )
This equipment generates, uses and can radiate
radio frequency energy and if not installed and
used properly, that is, in strict accordance with
the manufacturer’s instructions, may cause
interference to radio communication. It has been
tested and found to comply with the limits for a
class A computing device in accordance with the
specifications in Subpart J of part 15 of FCC
rules, which are designed to provide reasonable
protection against such interference when the
equipment is operated in a commercial
environment. Operation of this equipment in a
residential area may cause interference, in
which case the user at his own expense will be
required to take whatever measures may be
necessary to correct the interference. Changes
or modifications not expressly approved by the
manufacturer could void the user’s authority to
operate the equipment.
This equipment has been tested and found to
comply with the limits for a class B computing
device in accordance with the specifications in
the European standard EN55022. These limits
are designed to provide reasonable protection
against harmful interference. This equipment
generates, uses and can radiate radio frequency
energy and if not installed and used in
accordance with the instructions may cause
harmful interference to radio or television
reception. However, there is no guarantee that
harmful interference will not occur in a particular
installation. If this equipment does cause
interference to radio or television reception,
which can be determined by turning the
equipment on and off, the user is encouraged to
correct the interference with one or more of the
following measures: (a) Reorient or relocate the
receiving antenna. (b) Increase the separation
between the equipment and the receiver. (c)
Connect the equipment to an outlet on a circuit
different from that to which the receiver is
connected. (d) Consult the supplier or an
experienced radio / TV technician for help.
Canadian Department of Communications
RFI s tatement
This equipment does not exceed the class A
limits for radio noise emissions from digital
apparatus set out in the radio interference
regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de
bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la
classe A prescrites dans le règlement sur le
brouillage radioélectriques publié par le
ministère des Communications du Canada.
AdderView GEM
Ins tallation and Us e
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
1. Introduction .................................................................................... 6
1.1 Key features ........................................................................................... 6
1.2 Package contents .................................................................................. 7
1.3 Remote controller contents .................................................................... 7
1.4 Product information ............................................................................... 8
2. Ins tallation ...................................................................................... 9
2.1 What you will need ................................................................................ 9
2.2 Mounting the AdderView GEM .............................................................. 10
2.3 Connecting your devices ....................................................................... 10
2.4 ‘Interface powered' operation without the optional power adapter ........ 11
2.5 Configuring your PCs ............................................................................ 11
2.6 Configuring the AdderView GEM .......................................................... 12
2.7 Summary of AdderView GEM configuration options .............................. 13
2.8 Resetting the AdderView GEM without disconnecting your devices ...... 14
2.9 Other useful installation information ...................................................... 15
2.10 Re-enabling a disconnected PS/2 mouse ........................................... 15
2.11 Hot plugging the AdderView GEM into running systems and
re-enabling disconnected PS/2 CPU mouse connections ................... 16
2.12 Upgrading the AdderView's flash memory .......................................... 17
3. Us ing the AdderView GEM ........................................................... 20
3.1 Power on status ..................................................................................... 20
3.2 Front panel keys and remote controller.................................................. 20
3.3 Status display......................................................................................... 21
3.4 Keyboard hotkey control ........................................................................ 22
3.5 Mouse control......................................................................................... 23
3.6 RS232 control ........................................................................................ 24
3.7 Cascading AdderView GEMs ................................................................ 24
3.8 Synchronising AdderView GEMs for multiple video head applications . 24
AdderView GEM
Ins tallation and Us e
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
4. AdderView GEM configuration options ....................................... 27
4.1 Screen saver time delay ........................................................................ 27
4.2 Autoscan lock on mode and delay time ................................................ 27
4.3 Mouse mode and mouse switching of channels .................................... 28
4.4 Keyboard hotkey combination ............................................................... 29
4.5 Cycling between all channels or just the active channels ..................... 30
4.6 Firmware functions (version query, mouse restore and reset) .............. 30
4.7 Setting a security password .................................................................. 31
4.8 Cascade query code ............................................................................. 32
4.9 Resolving slow mouse problems ........................................................... 32
4.10 Exit configure mode ............................................................................ 33
Appendices
A - Cable and connector specifications ................................................................ 34
B - Problem solving .............................................................................................. 38
AdderView GEM
Ins tallation and Us e
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Introduction
Thank you for purchasing the AdderView GEM. Your AdderView GEM is a high
performance keyboard, monitor and mouse sharing device which supports a wide
range of PC hardware and software platforms.
1.1 Key features
Control multiple PCs from a single keyboard, monitor and mouse.
Continuous keyboard and mouse emulation on all ports ensures problem free
computer bootup.
Interface powered operation – AdderView GEM draws its power from the
connected computers for maximum convenience.
Intelligent switching feature enables users to switch between all ports or just the
active ports.
Supports high bandwidth monitors at resolutions up to 1900 x 1440 with an
excellent video transfer characteristic - high bandwidth and low distortion.
Mixed AT/PS2 keyboards and PS2/RS232 mice supported as standard.
Flash upgradeable - AdderView GEM's firmware may be upgraded by connecting
a computer's serial port and running a download program.
Can be cascaded to provide a video switching network.
Video channels support Display Data Channel (DDC/DDC1/DDC2) signalling.
Password security prevents unauthorised use.
User options stored in EEPROM memory.
Remote control module for convenient operation.
Channel switching by front panel key, keyboard hotkey, or 3 button mouse.
Automatically restores keyboard and mouse states when channel changed.
Supports keyboard modes 1,2 and 3 and mouse prompt and stream modes for
maximum compatibility.
AdderView GEM
Ins tallation and Us e
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Can be controlled remotely via an RS232 serial port.
Includes screen saver, auto-scan and variable hotkey options.
Supports Microsoft IntelliMouse, IntelliMouse Explorer and other common wheel
mice.
Mouse restoration functions to enable ‘hot plugging’ of certain systems.
Keyboard, mouse and AdderView GEM resets may be performed without
disconnecting devices.
Supports IBM ThinkPad ‘Y’ cables.
Power and activity indication confirm correct operation.
Standard cable connections make installation easy and inexpensive.
All ports are active simultaneously – all PCs may all be booted at the same time.
Robust metal case ensures good shielding and video quality.
Supports desktop and laptop PCs, RS6000s, DEC Alphas, and Silicon Graphics
computers .
Supports very wide range of software including Windows 3.X, WFWG, 95, 98,
2000, NT, DOS, Unix, Linux, NetWare, OS/2, BSD etc.
Optional power adapter can be used for ‘video only’ or cascade applications.
1.2 Package contents
AdderView GEM.
This installation guide.
(Please note that a power adapter is NOT required for most applications and so is
not included. This may be purchased separately if required - part code
AVGPSU).
1.3 Remote controller contents (part code: RC1)
Remote control module.
Velcro strip for mounting remote controller.
AdderView GEM
Ins tallation and Us e
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
1.4 Product information
Figure 1 - AdderView GEM front view
Figure 2 - AdderView GEM rear view (4 port model)
Figure 3 - Remote control pad / dis play (optional acces s ory - part RC1)
AdderView GEM
Ins tallation and Us e
Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Ins tallation
2.1 What you will need
Cables to connect the AdderView GEM to each of your PC keyboard, video and
mouse ports. Cable specifications are given in appendix A. (You do not need to
connect a mouse cable if you are not using the mouse).
A monitor with a standard VGA/SVGA (15 pin) connector that will work when
connected directly to each of your PCs. AdderView GEM supports low and high
resolution monitors.
A standard AT or PS/2 style keyboard. If you are using an AT keyboard with a 5
pin connector you may connect this to the AdderView GEM using a standard AT to
PS/2 keyboard adapter.
A PS/2 style two or three button Microsoft or Logitech compatible mouse or a
Microsoft IntelliMouse / IntelliMouse Explorer compatible mouse. If you wish to use
the mouse to switch the AdderView GEM's channel then you will need a three button
mouse or an IntelliMouse.
(The AdderView GEM supports ‘Internet Mice’ that are compatible with the Microsoft
IntelliMouse. These are fitted with a wheel or other scroll control and sometimes
have additional buttons. Examples are: Microsoft IntelliMouse, Logitech Pilot
Mouse+, Logitech MouseMan+, Genius NetMouse and Genius NetMouse Pro.)
A suitable mouse driver for your PCs. Supported types are:
- PS/2 or RS232 two button mouse driver (any manufacturer).
- Microsoft mouse driver (including IntelliMouse).
- Logitech mouse driver (including two button, three button and wheel mouse)
Us e of PS/2 and RS232 s tyle mice with the AdderView GEM - All of the mouse
connections from AdderView GEM to PCs support either a PS/2 or an RS232
mouse. AdderView GEM automatically converts from the PS/2 mouse commands to
RS232 serial mouse commands. Serial mice types are selected by using an adapter
as described in Appendix A. The AdderView GEM will operate without a mouse
connected if you do not wish to use one.
AdderView GEM
Ins tallation and Us e
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2 Mounting the AdderView GEM
The AdderView GEM has been designed for use on a desktop or shelf in close
proximity to the user’s monitor and peripherals. The optional remote controller may
be used if you wish to locate the AdderView GEM on a desk or shelf that is some
distance from the monitor and peripherals.
2.3 Connecting your devices
Ensure that the optional power adapter is disconnected from the AdderView GEM
and that all the devices which are to be attached are switched off. Connect the
shared keyboard, PS/2 mouse and monitor to the connectors at the rear of the
AdderView GEM (see figs 1, 2 and 3). Next, connect each computer system unit in
turn with the keyboard cable, mouse cable and video cable. Adder 3-in-1
keyboard/video/mouse cables are recommended for maximum convenience. Any
unused computer connections can be left unconnected. To connect computers with
serial mouse connections and AT style keyboard connections use the adapters
specified in appendix A. If you have an existing 6-pin mini-DIN to 9-pin serial adapter
that came with a mouse it may not be suitable for use with the AdderView as there
are several different standard wiring configurations for these adapters.
The AdderView GEM is now ready for use and will start to operate as soon as one of
the attached PCs is powered on. If you are connecting to PCs using cables that are
longer than 5 metres or are cascading the AdderView GEM to another AdderView
GEM you will need to use the optional power adapter. When using the optional
power adapter, ensure that it is connected to the mains and powering the AdderView
GEM before you switch on the connected computers. Failure to switch the
AdderView GEM and computers on in the correct order can lead to the mouse
and/or keyboard not being recognised by the computers when they are switched on.
AdderView GEM
Ins tallation and Us e
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4 ‘Interface powered’ operation without the optional power
adapter
The AdderView GEM draws its power from the connected computers via the
keyboard cables. A single keyboard connection is normally sufficient to power the
AdderView GEM provided that the cable is no longer than 5 metres. If more than
one computer is connected then the power will be intelligently drawn from all
computers. Cables longer than 5 metres may be used provided that the AdderView
GEM is already powered by another connected computer or the optional power
adapter. If you are cascading the AdderView GEM to another AdderView GEM then
a power adapter must be connected to all AdderView GEMs.
2.5 Configuring your PCs
Configure your PC in the same way that you would if your keyboard, mouse and
monitor were all connected directly to your PC. AdderView GEM emulates Microsoft
compatible serial, IntelliMouse, IntelliMouse Explorer and PS/2 mice, so ensure that
your PC software is configured for a Microsoft mouse of the correct type. Refer to
the list of supported drivers in section 2.1.
2.6 Configuring the AdderView GEM
The AdderView GEM is supplied pre-configured with factory defaults which are
suitable for most applications. There are a number of more advanced options which
can be set by the user. These are stored in the AdderView GEM's EEPROM
memory and are retained when the power is disconnected.
The options may be changed whilst the AdderView GEM is in configure mode. You
may enter configure mode at initial power on or whilst the AdderView GEM is
running:
AdderView GEM
Ins tallation and Us e
Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
To enter configure mode at power on:
Switch off all the attached PCs and the AdderView GEM. Hold down the front panel
key whilst powering on the AdderView GEM. Remember that the AdderView GEM
draws its power from any attached PC via the keyboard cable and so will power itself
on when the attached PC is switched on or when the optional power adapter is
connected. Do not release the key until the AdderView GEM displays 'C' to show
that it has entered configure mode.
To enter configure mode whils t the AdderView GEM is running:
Hold down the front panel key for 5 seconds until the front panel display shows ‘C’.
In configure mode, options are entered by typing a letter followed by a number
followed by (return). Use ESC to abort the entry of an option. The AdderView GEM
will remain in configure mode until you type 'E' (return).
For example: to set hotkey option 2 type the following at the 'C' prompt
(at AdderView GEM 'C' prompt)
To exit configure mode type:
H2
f
E
f
2.7 Summary of AdderView GEM configuration options
Full details of each of the configuration options and their uses are given in section 4.
B1 - screen saver disabled (default)
B2 - Blank screen after 1 minute of inactivity
B3 - Blank screen after 2 minutes of inactivity
B4 - Blank screen after 4 minutes of inactivity
B5 - Blank screen after 8 minutes of inactivity
B6 - Blank screen after 12 minutes of inactivity
B7 - Blank screen after 16 minutes of inactivity
B8 - Blank screen after 20 minutes of inactivity
AdderView GEM
Ins tallation and Us e
Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
L1 - AdderView GEM locks on to active ports only during autoscanning (default)
L2 - AdderView GEM locks on to every port during autoscanning
L3 - AdderView GEM powers on in autoscan mode and locks on to active ports only
L4 - AdderView GEM powers on in autoscan mode and locks on to all ports
L5 – Allow the mouse to run at any speed (default)
L6 – Don't allow the mouse to run at very slow speeds
L7 - Cascade query code = AD (default)
L8 - Cascade query code = EF
T1 - 2 seconds autoscan delay time before switching to next port (default)
T2 - 5 seconds autoscan delay time before switching to next port
T3 - 7 seconds autoscan delay time before switching to next port
T4 - 10 seconds autoscan delay time before switching to next port
T5 - 15 seconds autoscan delay time before switching to next port
T6 - 20 seconds autoscan delay time before switching to next port
T7 - 30 seconds autoscan delay time before switching to next port
T8 - 60 seconds autoscan delay time before switching to next port
U1 - AdderView GEM channels are switchable using a 3 button mouse
or IntelliMouse (default)
(AdderView GEM reports 2 button mouse mode to PCs)
U2 - AdderView GEM channels are not switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports 2 button mouse mode to PCs)
U3 - AdderView GEM channels are not switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports 3 button mouse mode to PCs)
U4 - AdderView GEM channels are switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports IntelliMouse mode to PCs)
U5 - AdderView GEM channels are not switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports IntelliMouse mode to PCs)
U7 – Cycle between all ports when switching with ‘Hotkeys + Tab’ or three button
mouse (default)
U8 – Cycle between active ports only when switching with ‘Hotkeys + Tab’ or three
button mouse
AdderView GEM
Ins tallation and Us e
Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
H1 - Hotkey combination is CTRL + ALT + command key (default)
H2 - Hotkey combination is CTRL + SHIFT + command key
H3 - Hotkey combination is ALT + SHIFT + command key
H4 - Hotkey combination is RIGHT ALT + command key
H5 - Hotkey combination is LEFT ALT + RIGHT ALT + command key
H6 - Hotkey combination is LEFT CTRL + LEFT ALT + command key
H7 - Hotkey combination is RIGHT CTRL + RIGHT ALT + command key
H8 - No hotkey combination enabled
F1 - Display firmware first digit (Note: F1 is Ffollowed by 1NOT l)
F2 - Display firmware second digit
F3 - Display firmware third digit
F5 - Restore PS/2 mouse function
F6 - Restore IntelliMouse function
F8 - RESET all configurations to default settings. (Display confirms with 'r').
P - Sets password - see section 4.6 for instructions.
E - Exits configure mode and returns the AdderView GEM to normal operation
mode.
2.8 Res etting the AdderView GEM without dis connecting your
devices
The AdderView GEM draws its power from the connected computers and therefore
may only be fully powered down when all the connected computers have been
switched off or disconnected. However, the AdderView GEM may be reset without
disconnecting or powering down your computers by using the reset switch on the
underside of the unit. Performing a reset using this switch performs a complete
hardware reset on the AdderView GEM and is equivalent to switching off the power.
To perform a hardware reset, move option switch 8 to the ON position (halt and
reset) and then back to the OFF position (normal operation).
AdderView GEM
Ins tallation and Us e
Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
2.9 Other us eful ins tallation information
PC boot up s equence - When your PCs are powered on they communicate with
any attached keyboards and mice and setup parameters required by the particular
operating system. It is necessary for the AdderView GEM to be attached and
powered on during this sequence so that it can give the required responses and
keep track of all the modes and settings requested by each of the connected PCs.
Mous e characteris tics - do not unplug a PS/2 mouse connection from a PC whilst
the PC is on. Due to the design of PS/2 mice communications the mouse function on
the PC will be lost and you will have to re-boot the PC to regain normal operation.
Unplugging the mouse from the AdderView GEM will also cause it to stop operating
when it is plugged back in. RS232 mice can usually be unplugged and plugged back
in provided that a mouse was connected when the operating system initially booted.
The AdderView GEM is fitted with a PS/2 mouse recovery system which allows you
to disconnect and re-connect the shared mouse without powering down the system
(although this is generally not advisable) - see section 2.10 for details.
Keyboard and mous e mode s witching - The AdderView GEM keeps a log of the
keyboard and mouse mode and resolution settings requested by each of the
connected PCs. These settings are automatically restored to the shared keyboard
and mouse when the AdderView GEM channel is switched thus ensuring maximum
software compatibility. The keyboard num, caps and scroll lock states are an
obvious example of this process.
2.10 Re-enabling a dis connected PS/2 mous e
If you disconnect the shared PS/2 mouse from the AdderView GEM by accident
during operation then the mouse operation will be lost when the mouse is plugged
back in. To avoid having to reboot the entire system in this situation the AdderView
GEM is fitted with an automatic mouse recovery system.
With the PS/2 mouse disconnected, change the channel using the keypad or
keyboard hotkeys. The AdderView GEM detects that the mouse has been
disconnected and triggers the automatic recovery system. Plug in the PS/2 mouse
and the AdderView GEM will re-initialise it.
AdderView GEM
Ins tallation and Us e
Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Alternatively you can reset the keyboards and mice by holding down the front panel
key for 5 seconds. When the character ‘C’ is displayed on the front of the AdderView
GEM, press the front panel key again. A complete power off reset of the connected
keyboards and mice will then be performed. This function only resets the shared
keyboard and mice that are plugged into the control port. It does not affect the status
of any of the other ports on the switch or the CPU connections.
2.11 Hot plugging the AdderView GEM into running s ys tems and re-
enabling dis connected CPU PS/2 mous e connections
It is advisable to switch off the systems that are going to be connected to the
AdderView GEM before installation. However, if this is not possible then most
systems can be hot plugged by using the AdderView GEM’s mouse restoration
functions. The keyboard connection will normally restore itself automatically.
On many PCs, mouse movement will be lost if the PS/2 mouse is unplugged and
plugged back in whilst the PC is running. Mouse movement can then only be
restored by rebooting the PC. This is because the mouse drivers only setup and
enable the mouse when the PC is initially booted.
If you have switched off your AdderView GEM or you are attempting to ‘hot plug’ it
into a system that is already running, you may be able to restore lost mouse
movement using the AdderView GEM's mouse restoration functions.
Mous e res toration functions s hould be us ed with care as unpredictable res ults
may occur if the wrong mous e type is s elected. If in doubt res tore the mous e
by powering down the PC normally.
Standard PS/2 mouse data uses a different data format to IntelliMouse data and so
two reset functions are provided on the AdderView GEM. The type of data format
expected by the PC depends upon the driver and the type of mouse that was
connected when the driver was booted. The following table may be used as a guide.
Note that the mouse reset functions predict the likely mouse resolution settings but
may not restore the speed or sensitivity of the mouse exactly as they were when the
PC originally booted.
AdderView GEM
Ins tallation and Us e
Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Type of mous e / s ys tem
Connected at bootup
Driver type Likely expected
data format
Sugges ted
res toration
PS/2
PS/2
PS/2 only
PS/2
F5
F5
F5
F6
IntelliMouse
PS/2
IntelliMouse / AdderView GEM PS/2 only
IntelliMouse / AdderView GEM IntelliMouse
PS/2
IntelliMouse
To restore lost mouse movement on a CPU connected to the AdderView GEM:
1) Select the CPU that has lost its mouse movement
2) Press the select key on the front of the AdderView GEM for 5 seconds until ‘C’ is
displayed. You are now in configure mode.
3) To restore a PS/2 mouse connection press
F 5
f
Or, to restore an IntelliMouse connection press
F 6
f
4) Exit from configure mode by typing
E
f
5) Test the mouse movement by moving the mouse a short distance.
F5 - Restore PS/2 mouse function
F6 - Restore IntelliMouse function
2.12 Upgrading the AdderView's flas h memory
The AdderView GEM uses flash memory technology which enables the firmware
code to be upgraded by the user. Upgrades are performed by connecting a PC's
serial port to the AdderView's options port and running an upgrade program on the
PC. This upgrade program downloads the new firmware to the AdderView and
checks that the data has been programmed correctly.
AdderView GEM
Ins tallation and Us e
Page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
To perform a firmware upgrade on your AdderView GEM you will need a suitable
serial upgrade cable and an IBM PC compatible computer with an RS232 serial port
and an operating system that supports DOS. Upgrade cables may be purchased for
Adder Technology or may be made using the wiring specification given in Appendix
A4. You will also need to download the latest version of the AdderView GEM
To perform a flash upgrade on the AdderView GEM:
Step 1 - Connect your computer to the AdderView
Connect your computer's serial port to the AdderView GEM's options port (labelled
OPTIONS/FLASH).
Step 2 - Select flas h upgrade mode us ing option s witch 7
Move option switch 7 on the underside of the AdderView GEM to the ON position.
Step 3 - Res et the AdderView GEM
Reset the AdderView GEM by moving option switch 8 to the ON position (halt and
reset) and then back to the OFF position (normal operation). Alternatively you may
reset the AdderView by powering off all the attached computers and removing the
optional power adapter.
Step 4 - Ens ure that the AdderView is powered on
Ensure that the AdderView is powered on. It is normally possible to upgrade the
AdderView when it is powered from a single computer, however it is good practice to
ensure that there is the maximum possible power availability during flash upgrades
and so if possible ensure that all the computers are powered on. The upgrade
program monitors the AdderView's voltage and will not allow an upgrade to be
performed if the voltage is insufficient.
The display should now show:
AdderView GEM
Ins tallation and Us e
Page 18
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 5 - Run the upgrade program
The latest version of the AdderView GEM firmware is available from the Adder
supplied as a pair e.g.
AVG129.EXE
AVG129.HEX
and should be downloaded to the same directory on your PC. Run the file
AVGxxx.EXE (e.g. AVG129.EXE) and follow the on-screen instructions. During the
upgrade the display will show an upper case U and the dot will flash to show that the
upgrade is in progress.
The display will again show a lower case U when the download is complete. Move
option switch 7 to the OFF position to exit upgrade mode and start normal operation.
You may check the new firmware version by entering configure mode and using the
firmware version query function.
Some us eful is s ues to bear in mind when performing flas h upgrades
The upgrade program rewrites the AdderView's firmware code. If the upgrade
process is interrupted then the AdderView will have invalid code and will not be able
to operate. It is therefore good practice to ensure that the upgrade process is always
fully completed. A partial or failed upgrade may be rectified by performing another
upgrade. If the upgrade process is interrupted accidentally then you should
immediately repeat the upgrade process without moving switch 7 from the flash
upgrade (ON) position. Switch 7 forces the AdderView into flash upgrade mode and
prevents the upgraded code from being run. Running faulty or partially upgraded
code may have unpredictable results and may damage your AdderView or
computing equipment. For obvious reasons, the code that the AdderView uses to
perform upgrades is not itself upgradeable - a common problem on some flash
upgradeable products that could effectively be destroyed by a partial upgrade!
WARNING - Running faulty or partially upgraded code may have unpredictable
res ults and may damage your AdderView or computing equipment.
AdderView GEM
Ins tallation and Us e
Page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Us ing the AdderView GEM
This section explains the general operation of the AdderView GEM. We recommend
that you read this section before starting to use the product.
3.1 Power on s tatus
At power on the AdderView GEM selects computer 1 and displays '1'. If a password
has been set then ‘P’ will be displayed and the AdderView GEM will remain locked
until a valid password is entered.
3.2 Front panel key and remote controller
The front panel key is used to select which channel is currently controlled by the
shared keyboard, mouse and monitor ports. Pressing the key during normal
operation will cause the next channel to be selected.
The key can also be used to access the AdderView GEM’s configuration mode (see
section 2.6). To do this press the key and hold it down for 5 seconds until ‘C’
appears on the AdderView GEM’s front panel display.
An optional remote controller is also available which replicates the front panel key
and display, but can be located remotely from the AdderView GEM. This is
AdderView GEM
Ins tallation and Us e
Page 20
Download from Www.Somanuals.com. All Manuals Search And Download.
particularly useful in applications where the AdderView GEM is located away from
the desktop. The remote controller can be conveniently attached to your keyboard
with a couple of Velcro strips to give instant channel information and key control.
3.3 Status dis play
The status display usually shows the currently selected port. If autoscan mode is
selected, the segments will illuminate in sequence in a clockwise direction
interspersed with a display of the currently selected channel. If AdderView GEM has
been locked, ‘P’ will be displayed until a valid password has been typed to unlock
the unit. Data flow from the mouse or keyboard causes the dot to flash.
AdderView GEM
Ins tallation and Us e
Page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4 Keyboard hotkey control
AdderView GEM can be conveniently controlled by selecting channel, autoscan
mode or security locking from the keyboard. All of the hotkey control commands are
invoked by holding down the two hotkeys and then pressing a command key. By
default, the two hotkeys are ‘CTRL’ and ‘ALT’, although other combinations can be
selected by reconfiguring the hotkeys (see section 4.4). Once the hotkey command
has been activated you will need to release the hotkeys and the command key
before a new hotkey command is accepted by the AdderView GEM. HOTKEYs +
TAB is an exception and this allows you to 'tab through' the ports by holding down
the hotkeys and repeatedly pressing TAB.
The hotkey command are summarised below (note that the numbers on the numeric
keypad do not form part of a valid hotkey) :
‘HOTKEYs ’ and ‘1’ - selects channel 1
‘HOTKEYs ’ and ‘2’ - selects channel 2
‘HOTKEYs ’ and ‘3’ - selects channel 3
‘HOTKEYs ’ and ‘4’ - selects channel 4
‘HOTKEYs ’ and ‘TAB’ - selects the next channel
‘HOTKEYs ’ and ‘A’ - selects autoscan mode where each channel is displayed for
the selected time (see section 4.2). To cancel autoscan mode simply select any
fixed channel either by hotkey or using the AdderView GEM button.
‘HOTKEYs ’ and ‘0’ – switches off the video signal and displays 0. This will cause
some monitors to go into standby mode or switch off. The video signal can be re-
enabled by selecting a channel.
‘HOTKEYs ’ and ‘L’ - disables the AdderView GEM's keyboard and mouse and
displays 0. The video signal is switched off. If a password has not been set then the
AdderView GEM can be re-enabled by selecting a channel. If a password has been
set then the AdderView GEM displays 'P' to indicate that a valid password must be
entered to unlock the switch. Simply type the same key combination as was set
during configuration (see section 4.7) followed by the (return) key. Note - if anyone
has typed at the keyboard whilst in secure mode, it will be necessary to type (return)
first to clear the invalid password, then type the valid password followed by (return)
again.
AdderView GEM
Ins tallation and Us e
Page 22
Download from Www.Somanuals.com. All Manuals Search And Download.
Examples of common hotkey sequences (assuming CTRL + ALT hotkey option):
To s elect channel 2:
press ba2release 2ba
To 'tab through' channels :
press bavrelease vpress v
release vpress vrelease vba
3.5 Mous e control
Computers may conveniently be selected using a three button mouse. In order to
switch to the next computer simply hold down the central mouse button (the wheel
mouse button on an IntelliMouse) and click on the left hand mouse button to select
the next computer or the right hand mouse button to select the previous computer. If
the AdderView has been set to scan active ports then the next or previous active
channel will be selected. If it has been set to scan all ports then the next or previous
numerical channel in sequence will be selected (see section 4.5 for more details).
Mouse switching may be enabled or disabled by setting options during configuration
(see section 4.3). When mouse switching is disabled the third button or wheel button
state is ‘passed through’ the AdderView and seen by the application software.
Hold down centre button (
Press and release left hand button
) to select next computer
)
Hold down centre button (
Press and release right hand button
) to select previous computer
)
(
(
AdderView GEM
Ins tallation and Us e
Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
3.6 RS232 control
AdderView GEM can be controlled by a remote RS232 device. To select a channel
the data rate of the sending device must be set to 1200 baud, 8 bits, no parity and 1
stop bit. No handshaking is used by the AdderView GEM. Simply send the character
for the channel which needs to be selected, for example ASCII ‘1’ (hex code 31) will
select channel 1, ASCII ‘2’ (hex code 32) will select channel 2 and so on. The
AdderView will echo the ASCII character back to the sending device when the
channel has been changed. The serial interface pins are found on the options
connector on the rear of the AdderView. Pin assignments for this connector are
given in appendix A.
3.7 Cas cading AdderView GEMs
AdderView GEM switches can be connected together to expand the number of
connected computers. When cascading AdderView GEMs a power adapter
(AVGPSU) must be connected to each AdderView GEM. AdderView GEMs can be
connected in a cascaded tree structure. This can be particularly useful where
clusters of computers are located some distance from each other because each unit
acts as data booster and can each be up to 30 metres away from the next
AdderView GEM. The channel can be selected on remote AdderView GEM units
using an extension of the HOTKEY control .
For example, consider a situation where two AdderView GEM units are connected
together as shown below. To connect to the computer attached to port 3 on
AdderView GEM B the user would hold down the hotkey keys then press ‘2’ followed
by ‘3’, whilst keeping the hotkey keys pressed. This will have the effect of connecting
to port ‘3’ of the AdderView GEM which is connected into port ‘2’ of the first
AdderView GEM unit A.
For example to connect to port 3 on the AdderView GEM cascaded off port 2 of your
first AdderView GEM use:
press ba
2release
2
ba
3
press 3release
AdderView GEM
Ins tallation and Us e
Page 24
Download from Www.Somanuals.com. All Manuals Search And Download.
A typical cascade of two AdderView GEMs
3.8 Synchronis ing AdderView GEMs for multiple video head
applications
Multiple AdderViews may be connected together so that they operate in a
synchronised manner. Synchronised operation is useful for applications that require
multiple video signals to be switched together. This type of operation is usually
required where each computer is fitted with multiple video cards or video cards with
multiple video heads. Such configurations are typically required in banking and
engineering applications where greater video 'real estate' is required. Whenever the
AdderView's channel is switched it sends an RS232 command out on its serial
interface. The AdderView switches its channel if it receives the same command on
AdderView GEM
Ins tallation and Us e
Page 25
Download from Www.Somanuals.com. All Manuals Search And Download.
its serial interface. Consequently, by linking the serial interfaces a master unit may
be made to automatically switch a daisy chain of slaved units as shown in the
diagram below. The slave units will require the optional power adapters because
they cannot draw their power from the video link alone.
Synchronised AdderView GEMs used for a dual head video switching application
AdderView GEM
Ins tallation and Us e
Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
4. AdderView GEM configuration options
All the options described in this section are entered in AdderView GEM configure
mode - see section 2.6 for instructions on entering configure mode.
4.1 Screen s aver time delay
AdderView GEM contains a programmable screen saver which will blank the display
after the set time delay with no keyboard or mouse activity. Simply typing at the
keyboard or moving the mouse will re-enable the display. The display will flash whilst
the AdderView GEM is in screen save mode.
B1 - screen saver disabled (default)
B2 - Blank screen after 1 minute of inactivity
B3 - Blank screen after 2 minutes of inactivity
B4 - Blank screen after 4 minutes of inactivity
B5 - Blank screen after 8 minutes of inactivity
B6 - Blank screen after 12 minutes of inactivity
B7 - Blank screen after 16 minutes of inactivity
B8 - Blank screen after 20 minutes of inactivity
4.2 Autos can ‘lock on’ mode and delay time
AdderView GEM can be set to select each channel in turn for a period of time set by
the autoscan delay time. Autoscan mode is entered by typing the hotkey keys
together with ‘A’. By default, only those channels which have a powered up
computer connected to them will be scanned. Sometimes it may be desirable to
scan all channels, even if the attached computer is switched off (this will simply
show a blank screen when it is selected). All the AdderView GEM’s ports will be
scanned if option L2 is selected. Some applications may also require the AdderView
GEM to power on in autoscan mode. This feature can be selected using the L3 or L4
options.
AdderView GEM
Ins tallation and Us e
Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
L1 - AdderView GEM only locks on to active ports during autoscanning (default)
L2 - AdderView GEM locks on to every port in turn during autoscanning
L3 - AdderView GEM powers on in autoscan mode and locks on to active ports only
L4 - AdderView GEM powers on in autoscan mode and locks on to all ports
T1 - 2 seconds autoscan delay time before switching to next port (default)
T2 - 5 seconds autoscan delay time before switching to next port
T3 - 7 seconds autoscan delay time before switching to next port
T4 - 10 seconds autoscan delay time before switching to next port
T5 - 15 seconds autoscan delay time before switching to next port
T6 - 20 seconds autoscan delay time before switching to next port
T7 - 30 seconds autoscan delay time before switching to next port
T8 - 60 seconds autoscan delay time before switching to next port
Note: Autoscan mode is ended simply by selecting a fixed channel using the
keypad, the keyboard hotkeys or the mouse.
WARNING - Many modern monitors are fitted with automatic power s ave relays
and will s witch off after a few s econds if connected to an inactive PC. If you
are us ing s uch a monitor you mus t not us e the L2 feature. Cons tant s witching
on and off of your monitor's relay will eventually damage your monitor.
4.3 Mous e mode and mous e s witching of channels
A three button PS/2 mouse or an IntelliMouse can be used to switch channels on the
AdderView GEM. To switch to the next channel, the user simply holds down the
central button or wheel button and presses the left or right hand button to change
the channel (see section 3.5). If the user does not wish to take advantage of this
feature, it can be disabled by selecting U2, U3 or U5. If the third button is being used
to switch the AdderView GEM then it is not available for use with PC software
although the function of an IntelliMouse wheel is not affected. Consequently in
modes U1, U2 and U4 the AdderView GEM reports to the PCs that a 2 button
mouse is connected. If you wish to use the full function of a 3 button mouse or
IntelliMouse for your PC software then you should select options U3 or U5.
The AdderView GEM supports ‘Internet Mice’ that are compatible with the Microsoft
IntelliMouse. These are fitted with a wheel or other scroll control and sometimes
have additional buttons.
AdderView GEM
Ins tallation and Us e
Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Examples are:
Microsoft IntelliMouse
Logitech Pilot Mouse +
Logitech MouseMan+
Genius NetMouse
Genius NetMouse Pro
Standard PS/2 and IntelliMouse compatible mice can be connected to the control
port. You may configure your CPUs using Microsoft PS/2 or IntelliMouse drivers in
any combination as required. The IntelliMouse features are supported on both PS/2
and RS232 CPU connections. When using PS/2 CPU connections, the AdderView
GEM will automatically configure itself to the type of mouse requested by the driver.
If you are using RS232 CPU connections then you will need to select mouse options
U4 or U5 to enable the IntelliMouse features.
U1 - AdderView GEM channels are switchable using a 3 button mouse
or IntelliMouse (default)
(AdderView GEM reports 2 button mouse mode to PCs)
U2 - AdderView GEM channels are not switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports 2 button mouse mode to PCs)
U3 - AdderView GEM channels are not switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports 3 button mouse mode to PCs)
U4 - AdderView GEM channels are switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports IntelliMouse mode to PCs)
U5 - AdderView GEM channels are not switchable using 3 button mouse
or IntelliMouse
(AdderView GEM reports IntelliMouse mode to PCs)
4.4 Keyboard hotkey combination
The keyboard hotkey combination is used to change a channel, set autoscan mode
or secure the product (so that the password needs to be typed before it can be used
again). The following keyboard hotkey combinations can be selected. These hotkey
combinations are used together with the command keys to trigger the required
AdderView GEM function. The left and right shift key combination is particularly
AdderView GEM
Ins tallation and Us e
Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
suitable for extended keyboards where additional keys can be programmed to act as
a combination of other keys. Such keyboards are supplied with many Gateway 2000
computers. Programming spare keys to trigger the hotkey combination allows
channels to be selected via a single key stroke.
H1 - 'CTRL' and 'ALT' keys together (left or right hand keys operate) (default)
H2 - 'CTRL' and 'SHIFT' keys together (left or right hand keys operate)
H3 - 'ALT' and 'SHIFT' keys together (left and right hand keys operate)
H4 - 'RIGHT ALT' key
H5 - 'LEFT ALT' and 'RIGHT ALT' keys together
H6 - ‘LEFT CTRL’ and ‘LEFT ALT’ keys together
H7 - ‘RIGHT CTRL’ and ‘RIGHT ALT’ keys together
H8 - No hotkey enabled
4.5 Cycling between all channels or jus t the active channels
The AdderView GEM can be set to cycle between all channels or just the active
channels when using ‘Hotkeys + Tab’ or a three button mouse to switch the channel.
This avoids wasting time viewing channels that are not active. Option are:
U7 – Cycle between all ports when switching with ‘Hotkeys + Tab’ or three button
mouse (default)
U8 – Cycle between active ports only when switching with ‘Hokeys + Tab’ or three
button mouse
4.6 Firmware functions (vers ion query, mous e res tore and res et)
For technical support purposes, it may be necessary to find the firmware release
version for the control software in your AdderView GEM. For example, if the release
version is v1.29 the response shown to F1f will be a brief display of the digit
‘1’, then F2fwill be a brief display of the digit ‘2’, then F3fwill be a
brief display of the digit ‘9’. You can reset all of the configured options back to the
factory default states by typing F8f. Use options F5fand F6f
to restore mouse function on disconnected PS/2 CPU mouse connections.
AdderView GEM
Ins tallation and Us e
Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
F1 - Display firmware first digit (Note: F1 is Ffollowed by 1NOT l)
F2 - Display firmware second digit
F3 - Display firmware third digit
F5 - Restore PS/2 mouse function to the currently selected CPU’s mouse port
F6 - Restore IntelliMouse function to the currently selected CPU’s mouse port
F8 - Reset all configurations to factory default settings. An ‘r’ will show briefly on the
display to confirm that the reset has been completed.
4.7 Setting a s ecurity pas s word
There are many situations where unrestricted access to corporate file servers or
sensitive information needs to be controlled. In such circumstances, the AdderView
GEM can be locked away in a room or secure cabinet and controlled remotely. In
this mode typing the keyboard hotkeys together with 'L' will blank the screen,
disconnect the keyboard and mouse from all of the computers and display ‘P’ on the
AdderView GEM display. Control can only be regained by typing the correct
password on the keyboard.
To set the password in configure mode, first type ‘P’ then (return). The display on
AdderView GEM will change to show ‘=' and you can then type your password. The
password is not case sensitive and can be any combination of key strokes, including
the function keys, but excluding the (ctrl), (alt), (shift) and (return) keys. When you
have typed in your password type (return) to register it in the stored memory. Do not
worry if you type the password incorrectly, you can always re-enter configure mode
and set the password again. If you have lost the password and the AdderView GEM
is locked, the unit may be unlocked by powering down the AdderView GEM, entering
configure mode at power on (see section 2.6), and performing a complete reset
using the F8 function.
NOTE - The password consists of a combination of key strokes rather like the code
to a safe. The key strokes are not case sensitive and can include all the keys on the
keyboard (except ctrl, alt, shift and enter). Consequently the following 'password'
would be valid:
g
oFRED
AdderView GEM
Ins tallation and Us e
Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
4.8 Cas cade query code
The AdderView GEMs use a special ‘query code’ to detect whether or not they are
connected to another AdderView GEM. By default your AdderView GEM uses query
code AD. SmartView (another range of keyboard / mouse / video switches from
Adder Technology) units with firmware versions less than 1.09 used query code EF.
This was found to conflict with a small number of other (rare) devices that used the
same query code so an alternative query code was provided to ensure compatibility.
Either query code may be used but you should make sure that all cascaded
AdderView GEM and SmartView units are set to use the same query code. If any of
the cascaded SmartViews have firmware versions less than 1.09 then the cascade
query code for all the AdderView GEMs and SmartViews should be set to EF.
L7 – Cascade query code = AD (default)
L8 – Cascade query code = EF
4.9 Res olving s low mous e problems
Due to certain technical reasons some systems running particular combinations of
operating system and mouse drivers are sensitive to small timing changes relating to
mouse communications. The introduction of a switch like the AdderView inevitably
causes some timing changes and in rare cases interactions have been observed
that causes the mouse to run very slowly. Certain HP Vectra computers running
later versions of Windows NT with Logitech mouse drivers and Logitech mice have
been observed to exhibit such interactions with older switches. One solution to this
problem is to change the mouse driver.
The AdderView GEM is a high performance device that is carefully engineered to
minimise such interactions and should not exhibit this characteristic. Nevertheless
such interactions are unpredictable and so the AdderView is fitted with a feature that
ensures that the mouse can never operate at a very slow rate regardless of such
interactions. This feature is activated using the following options:
L5 – Allow the mouse to run at any speed (default)
L6 – Don't allow the mouse to run at very slow speeds
AdderView GEM
Ins tallation and Us e
Page 32
Download from Www.Somanuals.com. All Manuals Search And Download.
4.10 Exit configure mode
When you have finished configuring any special options, simply type ‘E’ followed by
(return) to exit configure mode and return to normal operation mode. The attached
computers can now be switched on.
AdderView GEM
Ins tallation and Us e
Page 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A. Cable and connector
s pecifications
IMPORTANT NOTE
The maximum cable lengths s upported vary widely between devices and
cables . It may be pos s ible to us e cables that are longer than thos e s pecified
below with certain PCs and peripherals but this cannot be guaranteed. If you
experience problems try us ing s horter cables .
A1. Keyboard, monitor and mous e to AdderView GEM
All of the shared devices plug directly into the relevant ports at the rear of the
AdderView GEM. If you use an AT style keyboard you will need an AT (5 pin DIN
female) to PS/2 (6 pin mini-DIN male) converter.
Cable s pecification (s elf-powered operation):
Keyboard, monitor and mouse cables should be no longer than 2 metres.
Cable s pecification (with optional power adapter):
Keyboard, monitor and mouse extension cables can be used to increase the
distance from AdderView GEM up to 10m. Most keyboards and mice will also
operate at distances of 20 metres.
A2. AdderView GEM to PCs 1 to 4
Cable s pecifications :
Video - 15 pin high density male D connector to 15 pin high density male D
connector wired as a standard VGA PC to monitor cable. There are two types
commonly available. The best type cables which will give excellent quality are
constructed with coaxial cable cores. Cheaper ‘data’ cables are often used, but can
degrade video quality if used over longer distances. Avoid using 'data' cables longer
than 2 metres unless the video quality is not important. Good quality coaxial video
cables may be run at distances up to 30 metres with little loss of video quality. If you
AdderView GEM
Ins tallation and Us e
Page 34
Download from Www.Somanuals.com. All Manuals Search And Download.
wish to make use of the DDC (Display Data Channel) capabilities of the AdderView
GEM then you will need to use cables that have the DDC signalling lines connected
(pins 12 and 15 on the 15-way video connector). Not all video cables have these
DDC lines connected.
Keyboard and PS/2 mice - 6 pin mini-DIN male connector to 6 pin mini-DIN male
connector with all lines connected straight through (1-1,2-2 etc.). If the PC has a 5-
pin DIN AT style keyboard connector you will need a PS/2 to AT keyboard adapter
6-pin mini-DIN female to 5-pin DIN male (readily available). For ‘interface powered’
operation without the optional power adapter the cables should be no longer than 5
metres (see section 2.4 for more details). For operation with the power adapter,
cables should be no longer than 30 metres.
RS232 s erial mice - these require a special converter to connect the RS232 lines
present on the AdderView GEM mouse ports to the RS232 port on a PC.
Cables should be no longer than 30 metres.
NOTE - There are s everal common wiring s pecifications for 6-pin mini-DIN to
9-pin s erial adapters . If you have an adapter that has been s upplied with a
mous e it may have a completely different internal wiring to that s hown above
and may not be compatible with the AdderView
AdderView GEM
Ins tallation and Us e
Page 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Recommended cables :
3-in-1 keyboard, video and mous e combination cable - For convenience,
neatness and high video quality we recommend the Adder brand 3-in-1 combination
cables. These cables are constructed with tri-coax video links to ensure that high
video quality is maintained. They also support DDC signalling and are colour coded
in PC99 specification colours for your convenience. These match the colours used
on the back of your AdderView GEM and most modern PCs. These cables are
available in various different lengths to suit your requirements. They may be
purchased with or without the adapters for AT keyboards and RS232 serial mice.
Please quote the following part codes when ordering from your supplier.
Part Code
Des cription
VKVM-2M
3-in-1 Adder cable, 2 metres long
VKVM-2M-AT
VKVM-5M
3-in-1 Adder cable, 2 metres long with AT and serial adapters
3-in-1 Adder cable, 5 metres long
VKVM-5M-AT
VKVM-10M
VKVM-10M-AT
3-in-1 Adder cable, 5 metres long with AT and serial adapters
3-in-1 Adder cable, 10 metres long *
3-in-1 Adder cable, 10 metres long with AT and serial adapters *
* The optional power adapter may be required (see section 2.4).
A3. Options port pin as s ignments
The 15 way D connector located on the back of the AdderView GEM (labelled
OPTIONS / FLASH) provides connections for the remote control module and allows
an external RS232 device to control the AdderView GEM. See section 3.6 for more
details.
Pin 9 = GND
Pin 10 = TXD
Pin 11 = RXD
Other pins to be left unconnected
AdderView GEM
Ins tallation and Us e
Page 36
Download from Www.Somanuals.com. All Manuals Search And Download.
A.4 Flas h upgrade cable connection
The cable connections shown below are to connect either COM1 or COM2 of a PC
to the AdderView GEM to allow flash upgrades.
A.5 RS232 s ynchronis ation cable pin as s ignments
The cable connections shown below are to connect two AdderView GEMs together
for synchronised operation (see section 3.8)
AdderView GEM
Ins tallation and Us e
Page 37
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B. Problem Solving
Problem:
Poor video quality with smearing fuzziness or ripple.
Action:
Use screened coaxial video cables to connect your devices to the AdderView GEM.
Problem:
Mouse does not move cursor on screen.
Action:
Ensure that the mouse and computer are both connected to AdderView GEM before power is
connected and ensure that the AdderView GEM is powered on before the attached computer. Ensure
that your software is configured to accept a Microsoft compatible mouse of the type that you have
connected (PS/2 or RS232). If you move the mouse and the activity indicator (dot on 7 segment
display) does not flash then the AdderView GEM is not receiving data from the mouse. Check the
mouse connection to the AdderView GEM, try resetting the mouse using the reset function (section
2.10) or re-powering the AdderView GEM. If you are attempting to connect the AdderView GEM to a
CPU with a PS/2 mouse connection that has not been powered down then you will need to use the
mouse restoration functions F5 or F6 (see section 2.11).
Problem:
Keyboard does not function or functions intermittently. Num lock light does not always come on when
the num lock key is pressed.
Action:
Some older keyboards were designed for use with specific computers and are not truly AT or PS/2
compatible. These are not common but if you experience problems try another keyboard.
Problem:
Mouse causes channel to change.
Action:
Some cheaper mice are not fully compatible with the AdderView GEM and can lose data causing the
channel to be changed (if mouse switching of channels is enabled). If you experience this problem
then change the mouse and use a Microsoft, Logitech, IBM, Compaq or Hewlett-Packard type. Ensure
that you are using a Microsoft compatible mouse driver on your PC. Some other manufacturers’
drivers may switch the mouse to use a proprietary mouse data format not supported by the AdderView
GEM. If you have unplugged and re-connected a mouse to the AdderView GEM then ensure that you
reset it using the mouse reset function (see section 2.10).
Problem:
Mouse jumps around the screen after disconnecting the mouse cable or powering down the
AdderView GEM.
Action:
If you have disconnected and re-connected a CPU mouse cable or you have powered down the
AdderView GEM then the mouse data format may be out of synchronisation with that required by the
PC (PS/2 or Intellimouse). Try the ‘restore Intellimouse’ function (F6) to resolve the problem or re-
power the CPU.
Problem:
Mouse moves very slowly but otherwise functions correctly.
Action:
Change the mouse driver to a Microsoft type or take the action recommended in section 4.9.
AdderView GEM
Ins tallation and Us e
Page 38
Download from Www.Somanuals.com. All Manuals Search And Download.
|