Acnodes Personal Computer FPC 8057 User Manual

FPC-8057  
5.7” STN LCD, Xscale-based touch screen  
computer  
User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ESD Precautions  
Integrated circuits on computer boards are sensitive to static electricity. To  
avoid damaging chips from electrostatic discharge, observe the following  
precautions:  
Do not remove boards or integrated circuits from their anti-static  
packaging until you are ready to install them.  
Before handling a board or integrated circuit, touch an unpainted  
portion of the system unit chassis for a few seconds. This helps to  
discharge any static electricity on your body.  
Wear a wrist-grounding strap, available from most electronic component  
stores, when handling boards and components.  
Trademarks Acknowledgments  
Acnodes Corp is a trademark of Acnodes Co., Ltd.  
IBM is a registered trademark of International Business  
Machines Corporation.  
MS-DOS, Microsoft C and QuickBasic are trademarks of  
Microsoft Corporation.  
TURBO C is a trademark of Borland Inc. BASIC is  
a trademark of Dartmouth College. Intel is a  
trademark of Intel Corporation.  
Other brand names and trademarks are the properties  
and registered brands of their respective owners.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unpacking  
The FPC-8057 is packed in an anti-static bag. The product has components that  
are easily damaged by static electricity. Do not remove the anti-static wrapping until  
proper precautions have been taken. Safety instructions in front of this User’s  
Manual describe anti-static precautions and procedures.  
After unpacking the product, place it on a raised surface and carefully inspect the  
board for any damage that might have occurred during shipment. Ground the  
product and exercise extreme care to prevent damage to the product from static  
electricity.  
Integrated circuits will sometimes come out of their sockets during shipment. The  
FPC-8057 5.7” STN LCD, Xscale-based touch screen computer package  
includes the following:  
FPC-8057 * 1  
Driver CD *1  
USB sync. cable *1  
Touch pen * 1  
Fuse * 1  
Panel mount * 2  
Make sure that all of the items listed above are present.  
What To Do If There Is A Problem  
If there are damaged or missing parts, contact your supplier and/or dealer  
immediately. Do not attempt to apply power to the product if there is damage to any  
of its components.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Instructions  
Overview  
This section states the safety instructions, which must be followed when installing,  
operating and servicing the FPC-8057. If neglected, physical injury and death may  
follow, or damage may occur to controller and related equipment. The material in  
this chapter must be studied before attempting any work on, or with, the unit.  
Warnings and Notes  
This manual distinguishes safety instructions. Warnings are used to inform of  
conditions, which can, if proper steps are not taken, lead to a serious fault  
condition, physical injury or death. Notes are used when the reader is required to  
pay special attention or when there is additional information available on the  
subject. Notes are less crucial than warnings, but should not be disregarded.  
Readers are informed of situations that can result in serious  
physical injury and/or serious damage to equipment with the  
symbol shown to the left. A Warning symbol indicates that the  
reader should pay special attention to the accompanying text.  
Precautionary steps should be taken to insure that the  
installation is in compliance with warnings. Warnings include  
Warnings  
Warnings  
hazardous conditions that could cause personal injury or  
equipment damage if care is not taken. The text next to this  
symbol describes ways to avoid the danger.  
Dangerous Voltage Warnings: Warns of situations in  
which high voltage can cause physical injury and or  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
damage equipment.  
General warning: Warns of situations, which can cause  
physical injury and or damage equipment by means other than  
electrical.  
Electrostatic Discharge Warning: Warns of situations in  
which an electrostatic discharge can damage equipment.  
Readers are notified of the need for special attention or additional in formation  
available on the subject with the following symbols:  
CAUTION!  
Aims to draw special attention to it.  
Note:  
Note: gives additional information or points out more  
information available on the subject.  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Disclaimers --------------------------------------------------------ii  
ESD Precautions --------------------------------------------------iii  
Unpacking ---------------------------------------------------------iv  
Safety Instructions ------------------------------------------------ v  
Chapter 1 Introduction-------------------------------------------- 1  
1.1 General Description .........................................................1  
1.2 Features ...........................................................................2  
1.3 Specifications ...................................................................2  
Chapter 2 Installation Instructions---------------------------- 5  
2.1 Mounting Instructions .....................................................5  
2.1.1 Location Considerations ......................................... 5  
2.1.2 Making a NEMA-4 Mounting .................................. 5  
2.1.3 Environmental Considerations .............................. 7  
2.2 Power Connections ............................................................ 8  
2.2.1 Power Requirements......................................................9  
2.2.2 Grounding Requirements ..........................................11  
2.2.3 CE Requirements ........................................................ 12  
2.2.4 Safety Guidelines......................................................... 12  
2.3 Communications Connections ..................................... 14  
2.3.1 COM 1 [RS-232] ........................................................14  
2.3.2 COM2 [RS-232] & COM3 [RS-422/485] ................16  
2.3.3 Dip Switch ..................................................................17  
Table of Contents  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 CE Requirements ..........................................................18  
2.5 Dimensions of FPC-8057 .............................................19  
Chapter 3 Windows CE.NET ------------------------------ 21  
3.1  
Introduction ...............................................................21  
3.2  
Utilities .......................................................................22  
3.2.1 Soft-Keyboard ......................................................... 22  
3.2.2 System Settings ....................................................... 23  
3.2.3 IPSM ............................................................................ 26  
3.2.4 Startup........................................................................ 27  
3.2.5 Remote Desktop Connection (Windows XP  
only) ....................................................................... 28  
3.3 FPC-8057 Networking ..................................................31  
3.3.1 Networking via Ethernet ....................................... 31  
3.3.2 Networking via USB Client Port ........................... 32  
3.3.3 Web browser ........................................................... 34  
3.4 Application program development ...............................35  
3.4.1 Microsoft eMbedded Visual C++ 4.0 ................ 35  
3.4.2 FPC-8057 SDK............................................................ 37  
Appendix A Example --------------------------------------- 39  
Appendix B How to Update WindowsCE image ------- 41  
Appendix C How to use development tools-eMbedded  
C++4.0--- 43  
Table of Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Chapter 1  
Introduction  
1.1 General Description  
The FPC-8057 series are fan-less and compact-size touch panel  
computers. It equips with 5.7” STN LCD display, Windows CE.NET and  
low power consumption CPU, Intel Xscale PXA255. Therefore, FPC-  
8057 series are good cost-effective choices for operator interface  
applications.  
The FPC-8057 adopts most reliable and stable design. With fan-less CPU  
and CompactFlash card, FPC-8057 is especially suitable for vibration  
environment such as transportation, semiconductor etc. In addition, FPC-  
8057 is also bundled with Windows CE.NET, which forms a bridge that lets  
FPC-8057 be an open HMI solution for system integration. For connecting  
other devices, the FPC-8057 also provides several interfaces: RS-  
232/422/485, Ethernet etc.  
Introduction  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
1.2 Features  
z Fan-less and low power consumption CPU- Xscale PXA255 z  
5.7” QVGA color STN LCD  
z Windows CE.NET supported and flash ROM on-board z  
Slim and compact size design  
z Suitable for reliable and vibration application – Fan less and  
CompactFlash card  
z NEMA 4 / IP65 compliant front panel z  
Support Compact Framework  
z Over-voltage power protection – fuse  
1.3 Specifications  
z Construction: plastic molding housing  
z Display: 5.7" QVGA Color STN LCD  
z CPU and core logic: IntelXscale PXA255 z  
Flash ROM/SDRAM on board  
32 MB Flash ROM / 64MB SDRAM z  
1 CompactFlashcard slot z I/O: 2  
serial ports  
COM1: RS-232, COM2: RS-232/422/485 z  
1 Ethernet port (10Base-T) z 2 USB host ports  
z 1 USB client for ActiveSync  
z Sound output: 16 bit sound output z  
RTC: Dallas DS1685  
z Power input: 24 VDC, 0.5A maximum  
z Dimension (W x H x D): 204 x 150 x 48mm z  
Weight: 1.0kg  
Introduction  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
LCD Display  
z Display type: STN color LCD  
z Display size (diagonal): 5.7" z  
Max colors: 4096 z Resolution:  
320 x 240  
z Pixel pitch (HxV, mm): 0.36 x 0.36 z  
Viewing angle: 100° z Luminance  
(cd/m2): 150 z Storage temperature: -  
20~60°C z Operating temperature:  
0~45°C z Backlight: CCFL z Contrast  
ratio 30:1  
Touch screen  
z Type: 4-wire, analog resistive  
z Resolution: 320*240  
z Light transmission: above 80% z  
Life: 1 million activation minimal  
Fuse  
z BUSSMANN  
z Fast Acting, Glass Tube z  
Rating: 250VAC, 1A z Size:  
5x20mm  
Environmental Specifications  
z Operating temperature: 0° ~ 45°C (32° ~ 113°F)  
z Relative humidity: 10% ~ 90% @ 40°C, non-condensing z  
Shock (operation): 10 to 25Hz(X,Y,Z direction 2G  
30minutes) z  
EMI: Complies FCC class A  
Introduction  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
z CE: Complies with EN50081-2 and EN50082-2 standards z  
Front panel meets NEMA4 / IP65  
Introduction  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Chapter 2  
Installation Instructions  
2.1 Mounting Instructions  
2.1.1 Location Considerations  
Care should be taken when locating equipment behind the unit to ensure  
that AC power wiring, PLC output modules, contactors, starters and relays,  
and any other source of electrical interference are located away from the  
back of the unit.  
Particular note should be taken to the position of variable speed drives and  
switching power supplies. Their input and load cables should be screened  
to a central star earth point.  
2.1.2 Making a NEMA-4 Mounting  
The unit can be mounted into panels with a depth of  
4”(105mm). It is recommended that the unit be mounted  
Panel Details on the front panel of a steel enclosure, through an  
appropriate opening*. Allow a clearance of 1”(25mm)  
around the sides of the unit for mounting hardware. Allow  
clearance for cable connections to the back of the unit. Unit  
depth may vary according to cable type used. Typically,  
plan a depth to accommodate at least 4”(105mm) behind  
the panel.  
Put the unit through the panel cut out. Slide the clamps  
into the 6 holes provided around the case. Tighten the  
clamping screws in an even pattern until  
NEMA-4  
Mounting  
Installation Instructions  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
the unit is secured in the panel. Caution!  
Do not over tighten mounting clamps!  
Specifications Note:  
Note:  
To seal to NEMA-4 specifications, all supplied mounting  
clamps must be used and panel cannot flex more than  
0.010”.  
Installation Instructions 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.1.3 Environmental Considerations  
z The FPC-8057 are to be used indoors as built in displays. Make sure  
that the displays are installed correctly and that the operating limits are  
followed (See Specifications).  
z
Do not operate the unit in areas subject to explosion hazards due to  
flammable gases, vapors or dusts.  
z The unit should not be installed where fast temperature variations and/or  
high humidity are present. This will cause condensation of water in  
the device.  
z
Do not install these terminals in environments where have  
inflammable gases.  
Installation Instructions  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.2 Power Connections  
Make sure that all local and national electrical standards are met when the  
installing the unit. Contact your local authorities to determine which codes  
apply.  
Installation Instructions 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.2.1 Power Requirements  
The FPC-8057 can be powered by DC power only. The  
specified voltage range is +21 to 25 Volts DC. This  
insures compatibility with most controller DC systems. The  
power conditioning circuitry inside the unit is accomplished  
by a switching power supply. The peak starting current can  
be as high as 700mA.  
Power  
If the display does not come on within 2 seconds of  
power up, remove power. An internal fuse will prevent  
damage if the polarity of the DC power is incorrect. Check  
wiring to insure proper connections and try to power up  
again.  
Fusing  
Requirements  
An Internal fuse will prevent damage for over voltage  
condition however it isn’t guaranteed.  
DC voltage sources should provide proper isolation from  
main AC power and similar hazards.  
Caution  
High Voltage  
A Hard-wired EMERGENCY STOP should be fitted in  
any system using a FPC-8057 to comply with ICS  
Safety Recommendations.  
Do not power the FPC-8057 and inductive DC loads, or  
input circuitry to the controller, with the same power  
supply. Note: The 24 VDC output from some controllers  
may not have enough current to power the FPC-8057  
Caution  
Emergency  
Stop  
Wire lengths should be minimized (Maximum 1600’ (500  
m) shielded, 1000’ (300 m) unshielded).  
Caution  
Supply Voltage  
Wires should be run in pairs with a neutral or  
Condition  
Caution  
Wire Routing  
Installation Instructions  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
common paired with a hot or signal line.  
If wiring is to be exposed to lightning or surges, use  
appropriate surge suppression devices.  
Keep AC, high energy, and rapidly switching DC  
wiring separate from signal wires.  
Equip ungrounded DC supplies with a resistor and  
capacitor in parallel to earth ground. This provides a path  
for static and high frequency dissipation. Typical values to  
use are 1MOhm and 4700pF.  
To make a connection, strip about 3/8” of insulation off the  
end of the wire, turn the connector screw  
counterclockwise until the gap is wide open, insert the  
wire all the way in, and turn the screw clockwise until it’s  
tight.  
Connection  
Connect positive DC line to the ‘+24V’ terminal and the  
DC ground to the ‘0V‘ terminal.  
10  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
FUSE Replacement:  
The fuse use on FPC-8057 is:  
BUSSMANN  
Fast Acting, Glass Tube  
Rating: 250VAC, 1A Size:  
5x20mm  
Warning:  
Make sure the power off before replace the fuse. Do  
1.  
2.  
not replace the fuse with a different rating fuse.  
2.2.2 Grounding  
Requirements  
Chassis ground must be used. DC ground is not directly coupled to Earth  
ground internally. It is preferable not to ground DC negative return to  
chassis ground as poor site earths can introduce noise into a system, but if  
necessary an earth connection should be made, from the power supply  
return point to the central star earth point. Ground conductors should be as  
short and as large in size as possible. The conductors must always be  
large enough to carry the maximum short circuit current of the path being  
considered. Ground conductors should be connected to a tree from a  
central star earth ground point. This ensures that no ground conductor  
carries current from any other branch.  
Installation Instructions  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.2.3 CE Requirements  
To make a FPC-8057 comply with EMC directives, and to reduce  
susceptibility to electrical interference, a separate #14 AWG ground wire  
should be taken to the chassis ground terminal of the power connector. This  
ground connection should be run directly to the central star earth  
connection point (as recommended in most Installation Instructions).  
2.2.4 Safety Guidelines  
This section presents recommended installation practices, and  
procedures. Since no two applications are identical, these  
recommendations should be considered as guidelines.  
Hardware Considerations WARNING!  
The system designer should be aware that devices in Controller systems  
could fail and thereby create an unsafe condition. Furthermore, electrical  
interference in an operator interface, such as a FPC-8057 can lead to  
equipment start-up, which could result in property damage and/or physical  
injury to the equipment operator.  
If you, or your company, use any programmable control systems that  
require an operator or attendant, you should be aware that this potential  
safety hazard exists and take appropriate precautions. Although the specific  
design steps depend on your particular application, the following  
precautions generally apply to installation of solid-state programmable  
control devices. In addition, these precautions conform to the guidelines for  
installation of Controllers as recommended in the NEMA ICS 3-304 Control  
Standards.  
12  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Programming Considerations  
To conform to ICS Safety Recommendations, checks should be placed in the  
controller to ensure that all writable registers that control critical parts of  
plant or machinery have limit checks built into the program, with an out-of-  
limit safe shut down procedure to ensure safety of personnel.  
ICS 3-304.81 Safety Recommendations:  
Consideration should be given to the use of an emergency stop  
function, which is independent of the programmable controller.  
Where the operator is exposed to the machinery, such as in loading or  
unloading a machine tool, or where the machine cycles automatically,  
consideration should be given to the use of an electromechanical override  
or other redundant means, independent of the programmable controller, for  
starting and interrupting the cycle.  
If provision is required for changing programs while the equipment is in  
operation, consideration should be given to the use of locks or other  
means of assuring that only authorized personnel can make such  
changes.  
These recommendations are intended as safeguards against the failure of  
critical components and the effects of such failures or the inadvertent  
errors that might be introduced if programs are changed while the  
equipment is in operation. *  
z The ICS 3-304.81 Safety Recommendations are reproduced by  
permission of the National Electrical Manufacturers Association from  
NEMA ICS 3-304  
Installation Instructions  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.3 Communications Connections  
There are several ports in the back of the case. Please take the  
following information for reference.  
2.3.1 COM 1 [RS-232]  
Different cables are required for  
various devices.  
Cable  
Restrict cable length to less than 50’  
(15m) for RS-232 devices to avoid  
communications problems.  
Requirements  
Caution  
Shielded cable must be used for long  
lengths or cables run in an electrically  
noisy environment.  
Do not run cables next to AC power  
lines or near sources of electrical noise.  
Be sure that the cable ends have been  
inserted all of the way into mating  
connectors and are secure  
14  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Pin assignment of the 9 Pin, Female,  
SUB-D, COM1 [RS-232] Port.  
Pin Designations  
Note: This port is not used for  
downloading or for printing functions.  
COM1 [RS-232]  
Pin# Symbol Function  
1
2
3
4
5
6
7
DCD  
RxD  
TxD  
Data Carrier Detect  
Received Data  
Transmitted Data  
Data Terminal Ready  
Signal Ground  
DTR  
GND  
DSR  
RTS  
Data Set Ready  
Ready to send  
output  
8
9
CTS  
RI  
Clear to send input  
Ring Indicator  
Installation Instructions  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.3.2 COM2 [RS-232] & COM3 [RS-422/485]  
The 9 Pin, male, SUB-D, COM2 [RS-232] & COM3 [RS-422/485] Port  
on the back of the unit is the downloading port (PC Connector) and RS-  
485/422 communications port for connecting to a device.  
Connector COM2 [RS-232] & COM3 [RS-2422/485]  
Pin Designations  
COM2  
COM3  
COM3  
Pin# Symbol  
(RS-232)  
(RS-422)  
(RS-485)  
GND  
GND  
GND  
1
2
3
4
5
6
7
8
9
GND  
Tx+  
RS-422 Transmit  
RS-422 Transmit  
RS-422 Receive  
RS-422 Receive  
Tx-  
Data+  
Data  
Rx+  
Rx-  
GND  
RxD  
TxD  
Receive  
Transmit  
Not used  
16  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.3.3 Dip Switch  
Pin1 Pin2 Mode  
OFF OFF Normal  
ON  
OFF Touch Screen Calibrate mode  
OFF ON Boot Loader mode  
P
Pin3, 4 unused  
z Touch Screen Calibrate mode: In this mode when you power on the  
FPC-8057, the screen will display a “+” sign at the center of the  
screen. Use a stylus or finger to push the center of the “+” until it  
moves. The “+” moves to upper-left, lower-left, lower-right and upper-  
right corners. When all five “+” are done the “+” will disappear. The  
Touch Screen parameter will store at Flash Rom.  
Installation Instructions  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
z Boot Loader mode: Load new Windows CE.NET image file. If the FPC-  
8057 already load the CE image with boot loader. Set the DIP SW2  
ON then power ON into boot loader mode. Refer the load Win CE  
image document.  
2.4 CE Requirements  
EU directives that apply to the FPC-8057 Series:  
z EMC Directive (89/336/EEC, 92/31/EEC, 93/68/EEC)  
electromagnetic emissions and immunity  
z Machinery Directive (89/392/EEC, 91/368/EEC, 93/44/EEC, 93/  
68/EEC) machine safety  
The FPC-8057 Series has been designed to operate satisfactorily in  
electromagnetic noise (immunity) and without emitting high levels of electrical  
noise into the environment (emission). The units are designed to meet  
European Community standards when installed per the wiring instructions in  
this manual.  
Compatibility  
Standards  
The FPC-8057 has been designed to meet  
electromagnetic compatibility for industrial  
environments.  
• CISPR (EN 55011) Group 1, Class A Radiated  
Emissions levels  
• EN50081-2 Generic emission standard,  
industrial environment (Also US FCC Class A)  
• EN50082-2 Generic immunity standard,  
industrial environment  
18  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2.5 Dimensions of FPC-8057  
Installation Instructions  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
20  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Chapter 3  
Windows CE.NET  
3.1 Introduction  
The FPC-8057 series operator interface terminal is designed to serve on the  
Windows CE.NET platform. Designed from the ground up for the  
embedded marketplace, Windows CE.NET delivers a robust real-time  
operating system for rapidly building the next generation of smart mobile and  
small footprint devices. With a complete operating system feature set and  
end-to-end development environment, Windows CE.NET contains  
everything you need to create a custom Windows CE.NET–based device  
that requires rich networking, hard real-time, and a small footprint, as well  
as rich multimedia and Web browsing capabilities.  
Windows CE.NET  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.2 Utilities  
There are several useful utilities built in the standard Windows CE.NET  
OS of FPC-8057:  
3.2.1 Soft-Keyboard  
The FPC-8057 is dedicated to the small-sized operator interface. It is often  
inconvenient for users to attach a keyboard to such small machine. Thus,  
a software keyboard is embedded in the standard Windows CE.NET OS.  
Upon boot-up, a small keyboard icon will appear on the status bar. Tap  
this icon by the stylus to activate/hide this Soft-keyboard.  
22  
Windows CE.NET  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.2.2 System Settings  
FPC-8057 provides an integrated utility for users to make basic setting of  
the machine.  
Windows CE.NET  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
disappear. The Touch  
Screen parameter will  
store at Flash Rom.  
Backlight  
“LCD Settings” page of the cecp provides the function to turn off the LCD  
backlight, and thus elongates the period of service. For example, if the user  
wants the backlight turned off automatically after 10 minutes when the device  
was no longer used. The user must select “10 minutes” in the put down  
box and then press “OK” button. Then the screen save function is  
enabled. Once the backlight was turned off, events or perturbations from  
the touch screen can turn it on.  
On the other hand, if users want to disable the screen save function,  
select “Never” and press “OK” button.  
Windows CE.NET  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
MAC address  
The MAC address p  
age the block shows the  
network MAC address. S ave  
T ap the Save registry  
button, would save the reg istry data to the IPSM folder. Next time reboot  
the  
FPC-8057, Window s CE.NET system will use the stored registry data.  
26  
Windows CE.NET  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Or in FPC-8057 \Windows folder click the “backupreg.exe” and it will  
save the registry data too.  
IPSM(Intel Persisten t Storage Manager)  
The IPSM serves as a small capacity hard disk. You can store your dat a  
and application in the Flash ROM via IPSM function to prevent nexpected  
loss of data as power failure. Whe  
u
n power is  
shutdown and cold boot, the data in the Flash ROM area would be  
saved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.2.4 Startup  
After the system boot up, the startup execution function would  
a utomatically perform. This function is useful for control system to do the  
initialization p rocesses or some other programs.  
Step1: Create "startup" directory in in "\IPSM\".  
Step2: Copy executable files or Shortcut to "StartUp" directory,  
which is created in Step 1.  
An  
py  
alternative way to setup startup files is to make a shortcut and co it to  
"IPSM  
ecute a program with  
\StartUp". A shortcut can ex P  
arameters.  
Follow the following procedure to create the shortcut (.lnk) file.  
Windows CE.NET  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
A .lnk file is a text file that contains the command line for the linke d target,  
which may be enclosed in double quotation marks, along with the length of  
that command line. Optionally, you can also pass parameters into the  
linked target. By default, a .lnk file uses the following format.  
[number of ASCII characters after pound sign]#[command line]  
[optional parameters]  
For example, to start M yApp.exe and pass two optional parameters into  
the application, a sample MyApp.lnk file contains the following.  
40#\Windows\MyApp.exe parameter1 parameter2  
3.2.5 Remote Desktop Connection (Window s XP only)  
Use Remote Desktop Connection you can remotely control your  
computer.  
To use Remote Desktop, you need the following:  
Windows XP installed on your office computer, or  
Professional inst  
whichever computer you plan to operate remotely. This  
computer is known as the host.  
You must first enable the Remote Desktop feature on your office computer  
so that you can control it remotely from another computer. You must be  
logged on as an administrator or a member of the Administrators group to  
enable Remote Desktop on your Windows XP Professional-based  
computer.  
28  
Windows CE.NET  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
To create a new Remote Desktop Connection 1.  
Open Remote Desktop Connection.  
2. In Computer, type the computer nam e for your computer running Windows  
XP Professional that has Remote Desktop enabled and for which you  
have Remote Desktop permissions.  
Windows CE.NET  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.  
appears.  
Click Connect. The Log On to Windows dialog box  
4. In the Log On to Windows dialog box, type your user name, password,  
and domain (if required), and then click OK. The Remote Desktop  
window will open and you will see the desk top settings, files, and  
programs that are on your office computer. Your office computer will  
remain locked. Nobody will be able to work at your office computer without  
a password, nor will anyone see the work you are doing on your office  
computer remotely.  
Note: To change your connection settings, (such as screen size,  
automatic logon information, and performance options), click Option s  
before you connect.  
30  
Windows CE.NET  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.3 FPC-8057 Networking  
3.3.1 Networking via Ethernet  
The FPC-8057 is equipped with a 10Base-T Ethernet controller. To utilize it,  
change the device name when the FPC-8057 is first turned on.  
Step  
1 Click  
“Start/Settings/Control  
___ Panel” _____________________________________________  
2 Double click “Network and Dial-up Connections”  
3 Find the default device name.  
Change it to a unique one  
depending on  
the plan of individual LANs. ____ LAN90001 _______________________  
4 If the FPC-8057 is a nod e of a  
LAN with DHCP servers, it is  
now available.  
5 If the FPC-8057 is a nod e  
___ of a LAN with fixed IP  
Windows CE.NET  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
server, please consult with  
MIS to get specific IP address.  
Click “Start/Settings/Control  
Panel”. Double click “Network  
and Dial-up Connections” and  
update  
___ the IP address. _______________________________________  
6 Use the cecp utility “Save  
registry” to save this  
changed.  
The FPC-8057 can use the USB client to USB host cable connect the  
USB client port of the FPC-8057 and the USB host port of the host  
computer as following:  
Step  
Make sure the  
1
Microsoft ActiveSync  
service is properly  
installed on the host  
PC.  
Microsoft  
ActiveSync  
Power ON the  
2
FPC-8057.  
Before the Windows  
CE.NET boot up, don’t  
connect the USB  
cable.  
Windows CE.NET  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3 Connect the USB client  
port of the FPC-8057  
and the USB host port  
of the host PC by the  
USB client to USB host  
___cable. _______________________________________________  
4 When the “Add New  
Hardware Wizard”  
asks for the driver,  
select the file  
D:\FPC-8057\USBdri  
__ ver\ wceusbsh.inf _____________________________________  
5 Follow the onscreen  
instructions to establish a  
partnership and  
synchronize your FPC-  
8057with your desktop  
computer.  
6 Now you can  
synchronize the  
information between  
the FPC-8057 and host  
computer with  
ActiveSync.  
Windows CE.NET  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.3.3 Web browser  
The FPC-8057 built-in Windows CE.NET OS includes Microsoft IE sample. It  
can be used to browse web pages on World Wide Web via LAN or dial-up  
connection.  
Windows CE.NET  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.4 Application program development  
The FPC-8057 is bundled with built-in Windows CE.NET operating  
system and with Compact Framewrok. In real applications users need to  
execute various applications programs on it. However, unlike its other  
family the Windows CE.NET is a hardware-dependent operating system. That  
is to say, Windows CE.NET application programs are only portable in the  
source code level. Users must rebuild the runtime file for a different  
Windows CE.NET platform even though the source code may not be  
changed at all.  
To develop your application program, you can use two development  
tools. Visual Studio.NET or eMbedded Visual C++ 4.0.  
For Visual Studio.NET, you can download newest version of Compact  
Framework from Microsoft website.  
For eMbedded Visual C++4.0; the following development tools must be  
installed on the PC:  
z Microsoft eMbedded Visual C++ 4.0  
z Microsoft eMbedded Visual C++ 4.0 Service Pack 1 z FPC-  
8057 SDK  
3.4.1 Microsoft eMbedded Visual C++ 4.0 System  
Requirements  
To use Microsoft eMbedded Visual C++ 4.0 you need the following:  
z A desktop computer with a Pentium-II class processor, 450 MHz or  
faster  
Windows CE.NET  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
z Microsoft Windows® 2000 Professional SP2, Microsoft Window  
2000 Server SP2, or Microsoft Windows XP Professional.  
z 96 MB (128 MB recommended) memory for Windows 2000  
Professional or Windows XP Professional. 192 MB (256 MB  
recommended) memory for Windows 2000 Server.  
z CD-ROM drive required  
z VGA or higher-resolution monitor. A Super VGA (800 x 600 or larger)  
monitor is recommended.  
z
Mouse or compatible pointing device. z  
200 MB hard disk space.  
36  
Windows CE.NET  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
3.4.2 FPC-8057 SDK  
The FPC-8057 SDK provides developers with access to an extensive set of  
functions that are specific to the FPC-8057 hardware.  
Installing the FPC-8057 SDK  
Step  
Download or from  
1.  
FPC-8057 SDK CD  
find the  
FPC-8057_SDK.msi  
file.  
Double click the file’s  
name start the Setup  
Wizard.  
The installer will be  
2
prompted for  
acceptance of a  
license agreement.  
Following that, the  
SDK should install  
itself automatically on  
the host machine  
without further  
operator intervention.  
Windows CE.NET  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
When installation is  
3
complete the following  
message should  
appear: “Completing  
the FPC-8057 Setup  
Wizard”. The installer  
must press the “Finish”  
button in the install  
window to exit.  
38  
Windows CE.NET  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Appendix A  
Example Program  
The FPC-8057 offers loop back test program for two comports. Please  
select the program D:\FPC-8057\Example\Serial Test.  
Serial port loop back test program  
Before running the program, you need to connect two comports of the  
FPC8057.  
COM2  
(RS-232)  
COM1 (RS-232)  
RxD  
7
8
TxD  
Example Program  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
This page does not contain any information.  
40  
Example Program  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Appendix B  
How to Update WindowsCE image  
If you want to update new WindowsCE image to FPC-8057, you can follow  
the procedure.  
1. Download newest version of WindowsCE image from  
2. Save new WindowsCE image into CompactFlash card and  
rename it to “nk.bin”.  
3. Set the DIP switch as follows.  
4. Power on the FPC-8057. Then, it updates FPC-8057 image and  
automatic reboot and into Windows CE.  
How to Update WindowsCE image  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
This page does not contain any information.  
42  
How to Update WindowsCE image  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
Appendix C  
How to use development tools-  
eMbedded C++4.0  
The following procedure will show you how to use development  
tools-eMbedded C++4.0.  
1. Before you start to develop the application program, you need to install  
following three S/W to Host PC.  
(1) USB driver in the driver CD.  
(2) eMbedded C++ 4.0  
(3) Microsoft ActiveSync. software  
(4) SDK (Software Development kit) in the driver CD.  
How to use development tools  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
2. Plug synchronized cable which is in the package to the USB client port  
of the FPC-8057.  
3. Run Microsoft ActiveSync. software.  
44  
How to use development tools  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
4. Select “No”  
5. Host PC synchronizes to FPC-8057. Click the item “Explore” and  
fine all folders in the FPC-8057.  
How to use development tools  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
6. If you plug the CompactFlash card in the FPC-8057. You can fine out the  
folder “StorgeCard” in FPC-8057.  
7. Run eMbedded VC++4.0 in host PC..  
46  
How to use development tools  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
8. Open a new project  
How to use development tools  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPC-8057 User’s Manual  
10. If you install FPC-8057’s SDK successfully, you can select FPC-8057 in  
the item. Then, click “Run” to compile your application program  
into “.exe” file.  
11. The “.exe” file is being sent to the FPC-8057 sync. You can find it in  
FPC-8057.  
48  
How to use development tools  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ABC Office Trimmer 440 User Manual
Abocom Network Router FSW410 User Manual
Adcom Stereo Amplifier GFP 750 User Manual
Agilent Technologies Blood Glucose Meter AN 372 1 User Manual
Air King Ventilation Hood SEV24SSH User Manual
Alesis Stereo Equalizer DEQ230 User Manual
Alpha ToolComHK Limited Sander AIR 658 User Manual
Amana Dishwasher L0503010 User Manual
ATN Binoculars ATN PS 15 User Manual
Behringer Speaker B208D User Manual