Introduction  
Accton’s Zilla Hub is a compact dual-speed hub featuring 8  
10BASE-T/100BASE-TX auto-sensing ports.This hub is  
completely plug and play, no configuration necessary. This  
dual-speed hub contains two internal repeater buses – one for  
10Mbps traffic and another for 100Mbps traffic. Traffic passing  
between attached devices that operate at the same speed is  
confined within the appropriate repeater bus.  
The components of the Zilla Hub are shown in the figure  
below:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Zilla Hub  
Check the Package  
The Zilla Hub includes:  
• 1 Zilla Hub  
• 1 DC Power Adapter  
• 1 registration card (please return)  
• This user guide  
RJ-45 Connectors  
Accton’s Zilla Hub features 8 10BASE-T/100BASE-TX ports  
with RJ-45 connectors located on the side panel of the hub.  
Ports 1-8 are (computer) station ports. To connect to a  
workstation or server, attach straight-through unshielded or  
shielded twisted-pair cabling to any station port on this hub.  
Port 8 doubles as a station (computer) port and a cascade  
(uplink) port. The cascade port makes it convenient to connect  
cable from the hub to a station port on another hub or a  
switch.  
Mount the Hub  
The Zilla Hub can be placed directly on your desktop or  
stuck to a metallic vertical surface (using the magnetic foot  
pads on the bottom of the hub).  
Before you start installing the hub, be sure you find a  
suitable location at the center of the devices you want to link  
and near a power outlet.  
Connect PCs to the Hub  
1. Remove the rubber cover from an RJ-45 port.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Quick Installation Guide  
2. Install a 10 or 100 Mbps (10BASE-T or 100BASE-TX)  
network adapter card and driver in each  
computer you want to network.  
3. Prepare straight-through  
twisted-pair cables with RJ-45  
plugs. Attach one end of the  
cable to the RJ-45 port of the  
computer’s network adapter  
card and the other end to any  
available port on the hub.  
Notes: If you are using port 8, be  
sure the Daisy-Chain switch is set to "COMPUTER."  
Cascade Devices to the Hub  
If you need more ports, connect a station port on another  
device to the cascade port on the Zilla hub with straight-  
through twisted-pair cable, maximum 5 meters (19.68 feet).  
1. To make a direct connection to another compatible hub or  
switch, use the RJ-45 cascade port 8. Set the port  
selection switch to HUB and then  
connect to any station port on the  
other device. Alternatively, you  
can connect from any RJ-45  
station port on the hub to an  
uplink port on the other device.  
2. Prepare straight-through shielded  
or unshielded twisted-pair cables  
with RJ-45 plugs at both ends.  
Use 100Š Category 3, 4 or 5  
cable for standard 10Mbps  
Ethernet connections, or 100Š  
Category 5 cable for 100Mbps Fast  
Ethernet connections. When inserting an RJ-45 plug, be  
sure the tab on the plug clicks into position to ensure that  
it is properly seated.  
Notes: 1. Make sure each twisted-pair cable does not  
exceed 100 meters (328 feet).  
2. To connect to another hub or switch, you may  
also attach to station ports at both ends if you  
use crossover cabling.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Zilla Hub  
Verify System Operation  
Check each connection by viewing the port status indicators  
shown in the following table. The hub monitors the link status  
for each port. If the Port indicator fails to light when you  
connect a device to the hub, follow the troubleshooting advice  
detailed in the next section.  
Port and Hub Status LEDs  
LEDs  
Power  
Condition  
On  
Status  
Hub is receiving power.  
Link  
On  
Port has established a valid 10/100  
Mbps network connection.  
Activity  
Flashing  
Traffic is traversing the port.  
Troubleshooting  
Symptom: Power LED does not light after power on.  
Cause: Power outlet or power cord may be defective.  
Solution: 1. Check for loose connections.  
2. Check the power outlet by using it for another  
device.  
3. Replace the power cord.  
Symptom: Port LED does not light after connection is made.  
Cause:  
Hub port, network card or cable may be  
defective.  
Solution: 1. Check that the hub and attached device are  
both powered on.  
2. Be sure the network cable is connected to both  
devices.  
3. Verify that Category 5 cable is used for  
100Mbps connections and that the length of  
any cable does not exceed 100 meters (328  
feet).  
4. Check the network card and cable connections  
for defects.  
5. Replace the defective card or cable if  
necessary.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Quick Installation Guide  
Application Diagram  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Zilla Hub  
Specifications  
Standards Conformance IEEE 802.3 10BASE-T, IEEE 802.3u  
100BASE-TX  
Number of Ports  
Network Interface  
8 10/100 Mbps RJ-45 ports (one of which  
serves as a daisy-chain port)  
RJ-45: 100Š, UTP cable  
10BASE-T: Category 3, 4 or 5  
100BASE-TX: Category 5  
Switching Method  
MAC Address Table  
Memory Buffer  
Store-and-forward  
2K entries per system  
128 Kbytes per system  
Line speed  
Filtering Rate  
Forwarding Rate  
14,810 pps (at 10 Mbps ),  
148,810 pps (at 100 Mbps )  
Learning Rate  
Dimensions  
Line speed  
90 x 97.5 x 24 mm  
160 gm  
Weight  
Power Requirements  
Power Consumption  
Heat Dissipation  
Maximum Current  
Access Method  
Status LEDs  
10 VDC,0.6 A (from external power adapter)  
6 Watts maximum  
20.5 BTU/hr  
0.6 A @ 10 VDC  
CSMA/CD, 10 Mbps and 100 Mbps  
Power, Link, Activity  
Environmental  
Temperature  
0°C to 40°C  
-40° - 70°C / -40° - 158°F (storage)  
IEC721-2-1, 10% to 85% (non-condensing)  
CE Mark  
Humidity  
Certification  
Emissions  
FCC Class B, VCCI Class B, CISPR 22 Class B,  
EN55022 Class B  
Safety  
CSA/NRTL, TÜV/GS,CB  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Quick Installation Guide  
Certification  
FCC Class B Certification  
This device complies with Part 15 of the FCC Rules. Operation  
is subject to the following conditions:  
1. This device may not cause harmful interference, and  
2. This device must accept any interference received, including  
interference that may cause undesired operation.  
Warning: This equipment has been tested and found to comply  
with the limits for a Class B digital device, pursuant to Part 15 of  
the FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential  
installation. This equipment generates, uses and can radiate  
radio frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular  
installation. If this equipment does cause harmful interference to  
radio or television reception, which can be determined by  
turning the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following  
measures:  
Reorient or relocate the receiving antenna  
Increase the separation between the equipment and receiver  
Connect the equipment into an outlet on a circuit different  
from the one which the receiver is connected to  
Consult the dealer or an experienced radio/TV technician for  
help  
You are cautioned that changes or modifications not expressly  
approved by the party responsible for compliance could void  
your authority to operate the equipment.  
Note: In order to maintain compliance with the limits of a  
Class B digital device, Accton requires that you use a quality  
interface cable when connecting to this device. Changes or  
modifications not expressly approved by Accton could void your  
authority to operate this equipment. Suggested cable type is  
unshielded or shielded (UTP/STP) cable – Category 3 or  
greater for 10Mbps connections, and Category 5 for 100Mbps  
connections.  
Class B (Canada Department of Communications)  
This digital apparatus does not exceed the Class B limits for  
radio noise emissions from digital apparatus as set out in the  
interference-causing equipment standard entitled "Digital  
Apparatus", ICES-003 of the Department of Communications.  
Cet appareil numérique respecte les limites de bruits  
radioélectriques applicables aux appareils numériques de  
Classe B prescrites dans la norme sur le matériel brouilleur:  
"Appareils Numérques", NMB-003 édictée par le ministère des  
Communications.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Zilla Hub  
VCCI Class B Compliance (Japan)  
CE Mark Declaration of Conformance (for EMI  
and Safety - Europe)  
This is to certify that this product complies with ISO/IEC Guide  
22 and EN45014. It conforms to the following specifications:  
EMC: EN55022(1988)/CISPR-22(1985) class B  
EN60555-2(1995)  
EN60555-3  
class B  
IEC1000-4-2(1995)  
IEC1000-4-3(1995)  
IEC1000-4-4(1995)  
4kV CD, 8kV AD  
3V/m  
1kV - (power line),  
0.5kV - (signal line)  
3Vrms  
IEC1000-4-6(1995)  
This product complies with the requirements of the Low Voltage  
Directive 73/23/EEC and the EMC Directive 89/336/EEC.  
Warning! Do not plug a phone jack connector in the RJ-45 port.  
This may damage this device. Les raccordeurs ne sont pas  
utilisé pour le système téléphonique!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Quick Installation Guide  
Wichtige Sicherheitshinweise (German Safety Statement)  
1. Bitte lesen Sie diese Hinweise sorgfältig durch.  
2. Heben Sie diese Anleitung für den späteren Gebrauch auf.  
3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen.  
Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet  
sich ein angefeuchtetes Tuch zur Reinigung.  
4. Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und  
leicht zugänglich sein.  
5. Das Gerät ist vor Feuchtigkeit zu schützen.  
6. Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten.  
Ein Kippen oder Fallen könnte Beschädigungen hervorrufen.  
7. Die Belüftungsöffnungen dienen der Luftzirkulation, die das Gerät vor  
Überhitzung schützt. Sorgen Sie dafür, daß diese Öffnungen nicht  
abgedeckt werden.  
8. Beachten Sie beim Anschluß an das Stromnetz die Anschlußwerte.  
9. Verlegen Sie die Netzanschlußleitung so, daß niemand darüber fallen  
kann. Es sollte auch nichts auf der Leitung abgestellt werden.  
10. Alle Hinweise und Warnungen, die sich am Gerät befinden, sind zu  
beachten.  
11. Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten  
Sie es vom Stromnetz trennen. Somit wird im Falle einer  
Überspannung eine Beschädigung vermieden.  
12. Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder  
Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand bzw.  
elektrischen Schlag auslösen.  
13. Öffnen sie niemals das Gerät. Das Gerät darf aus Gründen der  
elektrischen Sicherheit nur von authorisiertem Servicepersonal  
geöffnet werden.  
14. Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu  
trennen und von einer qualifizierten Servicestelle zu überprüfen:  
a. Netzkabel oder Netzstecker sind beschädigt.  
b. Flüssigkeit ist in das Gerät eingedrungen.  
c. Das Gerät war Feuchtigkeit ausgesetzt.  
d. Wenn das Gerät nicht der Bedienungsanleitung entsprechend  
funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung  
erzielen.  
e. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt.  
f. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.  
15. Stellen Sie sicher, daß die Stromversorgung dieses Gerätes nach der  
EN 60950 geprüft ist. Ausgangswerte der Stromversorgung sollten die  
Werte von AC 7,5-8V, 50-60Hz nicht über oder unterschreiten sowie  
den minimalen Strom von 1A nicht unterschreiten.  
Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000  
beträgt 70dB(A) oder weniger.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Warranty  
Accton warrants to the original owner that the product delivered in this  
package will be free from defects in material and workmanship for a  
period of three (3) years from the date of purchase from Accton or its  
authorized reseller. For the warranty to apply, you must register your  
purchase by returning the registration card indicating the date of  
purchase and including proof of purchase. There will be a minimal charge  
to replace consumable components, such as fuses, power transformers,  
and mechanical cooling devices. The warranty does not cover the  
product if it is damaged in the process of being installed. Accton  
recommends that you have the company from whom you purchased this  
product install it.  
THE ABOVEWARRANTY IS IN LIEU OF ANY OTHERWARRANTY,  
WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING BUT NOT  
LIMITEDTO ANYWARRANTY OF MERCHANTABILITY, FITNESS FOR A  
PARTICULAR PURPOSE, OR ANYWARRANTY ARISING OUT OF ANY  
PROPOSAL, SPECIFICATION OR SAMPLE.ACCTON SHALL NOT BE  
LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.ACCTON  
NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR  
IT ANY OTHER LIABILITY.  
Copyright  
Copyright © 2000 by Accton Technology Corporation. All rights reserved.  
No part of this document may be copied or reproduced in any form or by  
any means without the prior written consent of Accton Technology  
Corporation.  
Trademarks  
Accton is a trademark of Accton Technology Corporation. Other  
trademarks or brand names mentioned herein are trademarks or  
registered trademarks of their respective companies.  
Disclaimer  
Accton makes no warranties with respect to this documentation and  
disclaims any implied warranties of merchantability, quality, or fitness for  
any particular purpose. The information in this document is subject to  
change without notice. Accton reserves the right to make revisions to  
this publication without obligation to notify any person or entity of any  
such changes.  
International Headquarters  
No. 1 Creation Road III,  
USA Headquarters  
6Hughes  
Science-based Industrial Park  
Hsinchu 300,Taiwan, R.O.C.  
Phone: 886-3-5770-270  
Irvine, CA 92618  
Phone Numbers -  
Sales:  
800-926-9288  
FAX:886-3-5770-267  
Support: 888-398-4101 or 949-707-4847  
Internet: [email protected]  
RMA:  
FAX:  
800-762-4968  
949-707-2460  
EH3008R  
E042000-R02  
150160-102  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Gas Grill PE420N User Manual
Abocom Network Card UHL1000C User Manual
ADC Network Card SignalOn Series User Manual
Adder Technology Network Card 2XPRO User Manual
Alto Shaam Oven AR 7H ELECTRONIC CONTROL User Manual
American Standard Plumbing Product 2585000ST User Manual
Atlas Model Vehicle 520099 User Manual
Audiovox Automobile Alarm PRO 9775 User Manual
Bang Olufsen Speaker 1 Jul User Manual
Beko Freezer CFD6914S User Manual