		 3M™ Dynatel™   
					Cable/Pipe/Fault Locator   
					2550/2573 Series   
					Operator’s Manual   
					2550 Pipe/Cable Locator   
					2550-iD Pipe/Cable and Marker Locator   
					2573 Cable/Pipe/Fault Locator   
					2573-iD Cable/Pipe/Fault and Marker Locator   
					June 2014   
					78-9000-0192-2 Rev C   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				12. Locating Buried Sheath Faults And Earth Return Faults ............................................40   
					A. Transmitter Setup..................................................................................................40   
					B. Pinpointing the Buried Fault .................................................................................41   
					13. Locating 3M™ Electronic Markers and 3M™ iD Markers............................................43   
					A. Enabling/Disabling Marker Types .......................................................................43   
					B. Alert Mode.............................................................................................................43   
					C. Single Marker Locate............................................................................................44   
					D. Dual Marker Locate ..............................................................................................45   
					E. 3M iD Marker Depth.............................................................................................45   
					F. Passive Electronic Marker (Non-iD) Depth...........................................................46   
					14. Creating/Editing Templates for 3M™ iD Markers........................................................47   
					A. Creating New Templates.......................................................................................47   
					B. Editing Templates..................................................................................................49   
					15. Writing 3M iD Markers ...............................................................................................50   
					A. Modifying Marker Data to be Written ..................................................................51   
					16. Reading 3M iD Markers ..............................................................................................53   
					17. Reviewing Marker Read/Write History .......................................................................53   
					A. Read History .........................................................................................................53   
					B. Write History [SK] ................................................................................................54   
					18. GPS Compatibility Operation......................................................................................54   
					A. Capturing the GPS Coordinates (Capture Mode / Mode 1)..................................55   
					B. Sending 3M iD Marker Data to GPS (Capture-Transmit Mode / Mode 2)...........56   
					C. Path Mapping with GPS........................................................................................56   
					19. Additional Applications ...............................................................................................58   
					A. Aerial Faults (Toning) ..........................................................................................58   
					B. Cable Identification ...............................................................................................59   
					20. Help Mode ...................................................................................................................60   
					21. 3M™ Dynatel™ PC Tool Kit and Locator Software Upgrades......................................61   
					22. Self Test of Receiver....................................................................................................61   
					23. Product Description And Optional Accessories...........................................................62   
					A. Product Description...............................................................................................62   
					B. Standard Configurations........................................................................................62   
					C. Optional 3M™ Accessories for 3M Dynatel™ Locators.........................................63   
					24. Receiver Specifications................................................................................................64   
					25. 12-Watt Transmitter Specifications..............................................................................66   
					26. Environmental and Regulatory Specifications.............................................................67   
					27. Rechargeable Battery Information...............................................................................67   
					78-9000-0192-2 Rev C   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Congratulations! You have just purchased one of the finest, most advanced locating   
					devices available today!   
					The 3M™ Dynatel™ Pipe/Cable Locators 2550 Series and 3M™ Dynatel™ Cable/Pipe/   
					Fault Locators 2573 Series are designed with all of the functionality of previous   
					Dynatel models plus the availability of 6 active locating frequencies and trace view   
					locating mode, while the iD versions have the enhanced capability to read and write   
					user information into the 3M iD markers. Information such as a pre-programmed   
					identification number, facility data, application type, placement date and other details   
					can all be read, stored and downloaded to your PC for enhanced resource management   
					with this revolutionary equipment. The Dynatel 2550-iD Pipe/Cable Locators and   
					Dynatel 2573-iD Cable/Pipe/Fault Locators will also search for two different types   
					of utility markers simultaneously. When used in conjunction with a hand-held GPS   
					device, the ability to transmit path and marker coordinates multiplies the potential to   
					the mapping industry. This equipment provides a simple system for mapping utility   
					information directly into CAD and GIS systems. The 2550/2573 Series transmitters are   
					12 watt units. They provide .5 watts, 3 watts and 12 watts of output power. 12 watts is   
					attained by utilizing the Cigarette Lighter Adapter or External Rechargeable Battery.   
					3M is dedicated to bringing you premium equipment with outstanding reliability, backed   
					by one of the best warranties in the business and outstanding service.   
					
					information.   
					4 
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				1. Safety Information   
					Please read, understand and follow all safety information contained in these instructions   
					prior to the use of the 3M™ Dynatel™ Pipe/Cable Locators 2500 Series. Retain these   
					instructions for future reference.   
					Intended Use   
					The 3M Cable/Pipe/Fault 2550/2573 Series Locators are used to identify the place-   
					ment of underground utility lines. The system must be installed as specified in the   
					3M™ Dynatel™ Cable/Pipe/Fault Locator 2550/2573 Series Operator's Manual. It has   
					not been evaluated for other uses or locations. If this equipment is used in a manner not   
					specified by 3M, the protections provided by the equipment may be impaired.   
					Explanation of Signal Word Consequences   
					Indicates hazardous situation which if not avoided, could result in   
					death or serious injury.   
					! Warning:   
					Indicates hazardous situation which if not avoided, could result in   
					minor or moderate injury.   
					! Caution:   
					Explanation of Product Safety Label Symbols   
					Do not throw away in normal trash.   
					Warning: Risk of electric shock   
					c 
					! WARNING   
					This WARNING applies to the following 3M Dyna-Couplers;   
					• 3" (75 mm) - Part number 3001   
					• 4.5" (114 mm) - Part number 4001   
					• 6" (150 mm) - Part number 1196   
					• All accessory kits containing any of the listed Dyna-Couplers - Part numbers 3019, 4519,   
					1196/C   
					A potential for electrical shock exists when using the Dyna-Coupler on cables energized with   
					electrical power. Use appropriate safety procedures.   
					DO NOT USE ON CABLES CARRYING IN EXCESS OF 600 VOLTS RMS.   
					78-9000-0192-2 Rev C   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				! WARNING   
					This WARNING applies to the use of the Direct Connect Cables and the Transmitter.   
					To avoid potential shock, or electrically damaging the Transmitter, when setting up the   
					Transmitter to locate using the Direct Connect method, follow these basic steps;   
					• 
					ALWAYS plug the Direct Connect Cable into the Transmitter Output Jack [T-6] BEFORE   
					connecting the leads to the cable/pipe to be located and the ground rod.   
					– Connect the red lead to the cable/pipe.   
					– Connect the black lead to ground rod.   
					A POTENTIAL FOR ELECTRICAL SHOCK, AND/OR TRANSMITTER ELECTRICAL DAMAGE, EXISTS   
					WHEN USING THE DIRECT CONNECT CABLE ON CABLES ENERGIZED WITH ELECTRICAL POWER   
					IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED. USE APPROPRIATE SAFETY PROCEDURES.   
					CHECK VOLTAGE BEFORE CONNECTING TRANSMITTER. VOLTAGE HIGHER THAN 240 VOLTS WILL   
					DAMAGE EQUIPMENT. FOLLOW STANDARD PROCEDURES FOR REDUCING THE VOLTAGE.   
					2. About This Manual   
					There are two basic models included in the 3M Dynatel Locator 2500 loctor Series. The   
					2550 is designed for pipe/cable locating. The 2573 loctor is designed for cable/pipe and   
					fault locating. The iD option (read/write capability to 3M™ iD Markers) is available for   
					both models. The 2550/2573 Series transmitters are 12 watt units. They provide .5 watts, 3   
					watts and 12 watts of output power. 12 watts is attained by utilizing the Cigarette Lighter   
					Adapter or External Rechargeable Battery. This instruction manual will include all features.   
					All instructions are applicable to all products, unless noted.   
					The 12-watt transmitter offers additional power output levels for improved induction   
					performance and 8 kHz (low frequency) induction for shallow facilities, such as risers.   
					The maximum output power in Direct Connect method is reduced to comply with FCC   
					limits. (FCC limits: 10 watts at 33 kHz and 1 watt at 82 kHz and 200 kHz)   
					In order to demonstrate all available functions, some illustrations depict the 2573-iD   
					receiver unit. The 2550 receivers and transmitters may vary from the illustrations shown.   
					6 
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3. Quick Start   
					A. Transmitter Battery Installation   
					Loosen the six screws on the battery compartment cover on the bottom of the transmitter.   
					Remove the cover.   
					Install six ‘C’ size alkaline cell batteries (LR14) into the compartment as indicated by   
					the polarity symbols (+ and –).   
					Replace the cover and tighten the screws.   
					6 'C' size (LR14)   
					Alkaline Batteries   
					Press and hold off [T-1] to manually test the batteries. The display and audio will   
					indicate one of the following levels: (OK w/solid tone = good; LO w/beeping tone =   
					low; "--" w/no tone = replace)   
					! CAUTION   
					To reduce the risks associated with fire and explosion:   
					• Do not short, excessively heat, or dispose of batteries in fire.   
					• Install batteries with proper polarity.   
					• Use only Alkaline "C" (LR14) sized batteries.   
					• Do not charge batteries.   
					• Do not use leaking batteries.   
					To reduce the risks associated with environmental contamination:   
					• Dispose of batteries and electronic components in accordance with all regulations.   
					• Ensure batteries are installed with correct polarity.   
					• Always remove batteries when storing the units for long periods of time.   
					78-9000-0192-2 Rev C   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				B. Receiver Battery Installation   
					Remove cap from receiver handle.   
					Install eight ‘AA’ size alkaline batteries (LR6) into the battery holder as indicated by the   
					polarity symbols (+ and –).   
					Attach battery holder to the PP3 connector in the receiver handle, and slide holder into   
					the handle. Replace the cap.   
					8 “AA” (LR6)   
					Alkaline Batteries   
					1. Twist cap to open battery   
					compartment.   
					2. Slide battery compartment   
					out of handle.   
					! CAUTION   
					To reduce the risks associated with fire and explosion:   
					• Do not short, excessively heat, or dispose of batteries in fire.   
					• Install batteries with proper polarity.   
					• Use only Alkaline "AA" (LR 6) sized batteries.   
					• Do not charge batteries.   
					• Do not use leaking batteries.   
					To reduce the risks associated with environmental contamination:   
					• Dispose of batteries and electronic components in accordance with all regulations.   
					• Ensure batteries are installed with correct polarity.   
					• Always remove batteries when storing the units for long periods of time.   
					The receiver batteries are tested for two seconds every time the unit is turned on.   
					The bar graph on the display will fill to the relative battery level.   
					The Battery Icon [12] (2573); [[11] (2550)] on the Locate Display will continuously   
					indicate the battery level.   
					8 
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				C. Cleaning Receiver and Transmitter Units   
					To clean the receiver and transmitter units, wipe with a damp cloth.   
					D. Service and Accessories   
					Information regarding service, accessories, or replacement parts can be obtained by   
					contacting 3M at 1-800-426-8688.   
					This equipment does not require annual calibration or maintenance.   
					E. Transmitter 2550 Keypad and Connector Definitions   
					Dynatel TM 2550   
					Frequency   
					- 
					+ 
					o 
					Output Level   
					off   
					on   
					T-1   
					T-2   
					T-3   
					T-4   
					T-5   
					T-6   
					T-7   
					[T-1] off: Turns unit off and performs battery test.   
					[T-2] on - Ohm-meter: Turns the unit on and places the unit in Ohm-meter mode. This   
					measures the continuity of the trace conductor/pipe and its far-end ground.   
					[T-3] on - Frequency: Turns the unit on and places the unit in Trace mode.   
					Select Frequency: Press Frequency [T-3] repeatedly to cycle through the   
					transmitter's active frequencies (577 Hz, 1 kHz, 8 kHz, 33 kHz, 82 kHz and 200   
					kHz). The selected frequency will be displayed [T-4]. ‘ALL’ indicates that the   
					following active frequencies are transmitting simultaneously: 577 Hz, 8 kHz, 33 kHz   
					and 200 kHz.   
					[T-4] Digital Display:   
					Indicator Flags: These flags coincide with the operational mode of the transmitter.   
					Starting from bottom left to upper right; Ohm-meter [T-2], Voltage (at start up the   
					transmitter checks for foreign voltage), Output Level [T-5] (no flag = normal output;   
					flag = high output; flashing flag = maximum output) and Trace mode [T-3].   
					Digital Display: Indicates frequency, relative current, resistance, battery level and   
					voltage (if present on target).   
					[T-5] Output Level: Cycles output power level; normal, high and maximum.   
					Normal=No Flag; High=Flag; Maximum=Flashing Flag (indicated in Digital Display [T-4])   
					NOTE: An external 12-volt power source is required to obtain Maximum Output level.   
					NOTE: 12-watt output level varies by frequency. Output is limited to 10 watts at 33   
					kHz and 1 watt at 82 kHz and 200 kHz using the direct connection method.   
					[T-6] Output Jack: Port for direct connect cables or Dyna-coupler cable.   
					[T-7] External Jack: Port to connect cigarette lighter adapter cable, or rechargeable   
					battery (2200RB). Input voltage level: 9-18 VDC.   
					78-9000-0192-2 Rev C   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				F. Transmitter 2573Keypad and Connector Definitions   
					TM   
					Dynatel 2573   
					Trace   
					- 
					+ 
					o 
					Output Level   
					off   
					on   
					T-1   
					T-2   
					T-3   
					T-4   
					T-5   
					T-6   
					T-7   
					[T-1] off: Turns unit off and performs battery test.   
					[T-2] on: Ohm-meter/Fault Locate/Tone: Turns the unit on and cycles through the   
					following commands when pressed repeatedly.   
					Ohm-meter: Measures the continuity of the trace conductor/pipe and its far-end   
					ground. It is also used to measure the fault resistance to earth.   
					Fault Locate: In this mode, the transmitter sends two alternating locating frequencies   
					(577 Hz and 33 kHz) as well as fault signals 10 and 20 Hz.   
					Tone: In the tone mode, the transmitter generates 577 Hz and 200 kHz signals.   
					[T-3] on: Trace (frequency): Turns the unit on and places the unit in Trace mode.   
					Select Frequency: Press Trace [T-3] repeatedly to cycle through the transmitter's   
					active frequencies (577 Hz, 1 kHz, 8 kHz, 33 kHz, 82 kHz and 200 kHz). The   
					selected frequency will be displayed [T-4]. ‘ALL’ indicates that the following active   
					frequencies are transmitting simultaneously: 577 Hz, 8 kHz, 33 kHz and 200 kHz.   
					[T-4] Digital Display:   
					Indicator Flags: These flags coincide with the operational mode of the transmitter.   
					(From top left to bottom right) Fault Locate mode [T-2], Tone mode [T-2], Trace   
					mode [T-3], Ohm-meter [T-2], Voltage (at start up the transmitter checks for foreign   
					voltage), and the Output Level [T-5] (no flag = normal output; flag = high output;   
					flashing flag = maximum output).   
					Digital Display: Indicates frequency, relative current, resistance, battery level and   
					voltage (if present on target).   
					[T-5] Output Level: Cycles output power level; normal, high and maximum.   
					Normal=No Flag; High=Flag; Maximum=Flashing Flag (indicated in Digital Display [T-4])   
					NOTE: An external 12-volt power source is required to obtain Maximum Output level.   
					NOTE: 12-watt output level varies by frequency. Output is limited to 10 watts at   
					33 kHz and 1 watt at 82 kHz and 200 kHz using the direct connection method.   
					[T-6] Output Jack: Port for direct connect cables or Dyna-coupler cable.   
					[T-7] External Jack: Port to connect cigarette lighter adapter cable, or rechargeable   
					battery (2200RB). Input voltage level: 9-18 VDC. (Only on 12-watt transmitters.)   
					10   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				G. Maximum Transmitter Output   
					An external 12V DC source is required for 12-Watt Output (Max setting) using a 12-watt   
					transmitter. Connecting the rechargeable battery (2200RB) to the External Jack [T-7]   
					will provide this external source, or the cigarette lighter adapter cable (included with   
					high-powered units) can be used to connect the DC power from a vehicle’s battery   
					source to the transmitter’s External Jack [T-7].   
					Press Output [T-5] twice for maximum output power mode.   
					The indicator flag (in [T-4]) will flash when the transmitter is in maximum output mode.   
					Note: The external DC source does not charge the internal batteries.   
					! WARNING   
					To reduce the risk associated with hazardous voltage:   
					• Potential for electric shock exists when handling connection cables while the transmitter is   
					ON. Make all connections prior to powering on the unit. Turn transmitter OFF before handling   
					connection cables.   
					• Voltage greater than 240 volts will damage equipment and could cause personal injury or   
					death. Make all connections before turning on the transmitter. Follow standard procedures   
					for reducing the voltage.   
					• Do not change or modify this product in any way.   
					H. Rechargeable Battery Information   
					The maintenance-free sealed lead (Pb)-acid   
					3M™ Dynatel™ Rechargeable Battery 2200RB   
					can be used as an auxiliary battery in   
					3M™ Dynatel™ 2500 Series 12 Watt Transmitters.   
					It plugs into the External Jack [T-7] and provides   
					power for the transmitter. When the rechargeable   
					battery is plugged in, normal output, high output,   
					and maximum output are available. When the   
					rechargeable battery is connected to the   
					transmitter, the alkaline batteries are bypassed.   
					The rechargeable battery is a lead acid battery rated at 5.4 amp-hours and is equipped with   
					a user replaceable fuse (5A/32V).   
					Note: The internal batteries must be at least 5.4 volts. Do not remove the alkaline   
					batteries from the transmitter when using the rechargeable battery. Rechargeable   
					battery, or cigarette lighter adapter cable, is required for maximum output level.   
					Rechargeable battery is shown installed in the well of the transmitter case.   
					78-9000-0192-2 Rev C   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				I. Receiver 2550 Keypad and Display Definitions   
					[10]   
					[11]   
					[12]   
					14   
					[9]   
					[8]   
					16   
					15   
					[7]   
					[6]   
					[13]   
					[1]   
					Access panel on   
					bottom side of   
					Receiver under   
					rubber cover   
					[SK]   
					[5]   
					[2]   
					[3]   
					[4]   
					[1] On/Off (Power): Turns unit on and off.   
					[2] TRACE (Locate) MODE: Toggles between Cable View locate mode and the four   
					other locate modes (cycles through available modes via the Mode soft key when in the   
					Cable/Pipe Locate display.   
					[3] GAIN: Adjusts the sensitivity of the receiver either up (+) or down (-) to maintain a   
					satisfactory signal level.   
					[4] DEPTH: Measures depth of target.   
					[5] Menu / OK: Sets the receiver to trace mode for locating cable or pipe and displays   
					Locate options, 3M iD Marker templates and writing mode options, setup screens for   
					configuration of the unit, i.e.: clock, language, depth units, marker data and frequencies,   
					COM settings and Help files. Also acknowledges setup entries (OK).   
					[SK] Soft Keys: There are four soft keys (yellow keys) on the receiver. The function   
					of each key is shown above the yellow key on the display screen. The functions will   
					change, depending on the operation mode of the receiver. For instruction purposes in this   
					manual, the display command is followed by [SK] to identify it as a soft key.   
					[6] BULB: Toggles the display backlight low, high, and off.   
					[7] Gain Level: Displays relative gain level.   
					[8] Signal Strength: Digital reading of the signal strength that the receiver is detecting   
					from the target.   
					[9] Speaker Volume Icon: Indicates the relative volume level of the receiver. When the   
					third ring is dotted and ‘xpnd' appears below the speaker volume icon, the receiver is in   
					“Expander” mode. This mode is used to pinpoint the target cable or pipe.   
					[10] Bar Graph: Graphical representation of the received signal.   
					[11] Battery Icon: Indicates battery level.   
					[12] Speaker Volume Control: Adjusts the volume of the receiver (off, low, medium,   
					high, and xpnd).   
					[13] Soft Key Commands: Definitions for each of the four soft key functions.   
					[14] External Jack: Port to connect cables from external devices such as the earth   
					contact frame (A-Frame), a second 3M Dyna-Coupler or a toning coil.   
					12   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				[15] Serial Port: RS232 port to connect the receiver to a PC via serial cable or USB-to-   
					Serial Adapter cable.   
					[16] Earphone Jack: Will fit standard 1/8 inch (3.175 mm) mini-jack mono earphone   
					plug (not included).   
					J. 2573 Receiver Keypad and Display Definitions   
					[11]   
					[12]   
					[13]   
					[10]   
					[9]   
					[8]   
					[7]   
					[6]   
					[14]   
					[1]   
					[SK]   
					[5]   
					Access panel on   
					bottom side of   
					Receiver   
					[2]   
					[3]   
					[4]   
					[1] On/Off (Power): Turns unit on and off.   
					[2] TRACE (Locate) MODE: Toggles between Cable View locate mode and the four   
					other locate modes (cycles through available modes via the Mode soft key when in the   
					Cable/Pipe Locate display.   
					[3] GAIN: Adjusts the sensitivity of the receiver either up (+) or down (-) to maintain a   
					satisfactory signal level.   
					[4] DEPTH: Measures depth of target.   
					[5] Menu / OK: Sets the receiver to trace mode for locating cable or pipe and displays   
					Locate options, 3M iD Marker templates and writing mode options, setup screens for   
					configuration of the unit, i.e.: clock, language, depth units, marker data and frequencies,   
					COM settings and Help files. Also acknowledges setup entries (OK).   
					[SK] Soft Keys: There are four soft keys (yellow keys) on the receiver. The function   
					of each key is shown above the yellow key on the display screen. The functions will   
					change, depending on the operation mode of the receiver. For instruction purposes in this   
					manual, the display command is followed by [SK] to identify it as a soft key.   
					[6] BULB: Toggles the display backlight low, high, and off.   
					[7] Gain Level: Displays relative gain level.   
					[8] Fault Finding Direction Indicators: Corresponds to the Earth Contact Frame   
					(A-Frame) probe (leg) colors.   
					[9] Signal Strength: Digital reading of the signal strength that the receiver is detecting   
					from the target.   
					[10] Speaker Volume Icon: Indicates the relative volume level of the receiver. When the   
					third ring is dotted and ‘xpnd' appears below the speaker volume icon, the receiver is in   
					“Expander” mode. This mode is used to pinpoint the target cable or pipe.   
					[11] Bar Graph: Graphical representation of the received signal.   
					78-9000-0192-2 Rev C   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				[12] Battery Icon: Indicates battery level.   
					[13] Speaker Volume Control: Adjusts the volume of the receiver (off, low, medium,   
					high, and xpnd).   
					[14] Soft Key Commands: Definitions for each of the four soft key functions.   
					[15] External Jack: Port to connect cables from external devices such as the earth   
					contact frame (A-Frame), a second 3M™ Dyna-Coupler or a toning coil.   
					[16] Serial Port: RS232 port to connect the receiver to a PC via serial cable or USB-to-   
					Serial Adapter cable.   
					[17] Earphone Jack: Will fit standard 1/8 inch (3.175 mm) mini-jack mono earphone   
					plug (not included).   
					4. Menu Displays   
					A. Main Menu/Locate Menu   
					When the Menu/OK [5] button is pressed, the display will toggle   
					between the MAIN MENU display and LOCATE MENU display.   
					The function appears on the display above each soft key [SK].   
					MAIN MENU Display   
					LOCATE MENU Display   
					1. Write Mode: System used to write information to 3M™ iD Markers   
					2. Data/Template: Displays marker history and   
					template creation/selection displays:   
					a. Read History – 100 memory locations for   
					Read 3M™ iD Markers   
					b. Write History – 100 memory locations for   
					written 3M™ iD Markers   
					c. User Templates – Create and edit iD   
					templates for 3M™ iD Markers (max =32)   
					d. Trace Templates – Create and edit   
					templates used to identify path (max = 5)   
					14   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3. COM   
					: Displays second level COM   
					Port setting display to configure RS232 port   
					communication with different devices –   
					a. PC – Receiver will communicate to a   
					computer   
					b. NMEA – Port is configured to accept   
					coordinates from GPS device   
					c. GIS – Port is configured to send 3M™ iD   
					Marker information or path information   
					to GPS device and receive coordinates   
					from GPS device   
					d. PDA – receiver will send 3M™ iD Marker   
					and path information in ASCII string.   
					4. >>More: Advances to next Main Menu display   
					MAIN MENU Display 2   
					5. Setup Tools   
					: Displays second and third   
					level displays for receiver configuration   
					a. Language   
					– Toggles between   
					English and alternate language   
					b. Clock   
					– Date and time stamped on   
					marker information and depth readings.   
					c. Contrast   
					display.   
					– Adjusts contrast of LCD   
					d. >>More - Advances to next menu display   
					78-9000-0192-2 Rev C   
					15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				e. Locate Modes – enable or disable locate   
					modes   
					f. Locate Frequencies – enable and disable   
					receiver frequencies in locate mode   
					g. Audio Configuration – Select audio   
					response of unit in Directional Peak and   
					Trace View modes   
					h. >>More - Advances to next menu display   
					i. Depth Units   
					– Choose unit of   
					measure; in, ft-in, or cm   
					j. Marker Type – enable and disable marker   
					utility types   
					k. Tone/Freq - External Port or Tone   
					Frequencies – enable and disable frequencies   
					that are detectable through the external port   
					of the receiver   
					l. >>More - Returns to first SETUP MENU   
					display   
					6. S/N#/Self Test: Displays information about unit   
					and can perform a self check test   
					7. Help   
					: Offers the user on-screen   
					instructions   
					8. >>More: Returns to first Main Menu display   
					16   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				5. Configuring The Receiver   
					In the setup mode, the units of depth measurement, time, date, and date format can be   
					set. The receiver can be configured to detect only certain frequencies and/or specific   
					utility markers (3M™ Dynatel™ Receivers 2550-iD and 2573-iD only) and activate   
					certain locating modes. User defined frequencies can be programmed, language of the   
					receiver can be selected, and tone frequencies set.   
					A. Selecting Depth Units   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					>>More [SK:h] + [SKToggle:i]   
					[SK:5] + >>More [SK:d] +   
					• The soft key command will toggle between inches   
					(in), centimeters (cm), and feet/inches (ft-in).   
					B. Setting the Receiver Clock   
					Set the time, date, and date format of the receiver. Depth and Current measurements are   
					time and date stamped, as well as read and write marker information (iD units only).   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					[SK:5] +   
					[SK:b]   
					• Press the left/right arrow [SK] to highlight the   
					digit of the date or time to change.   
					• Press the + or - [SK] to increment or decrement.   
					• When the date format is highlighted, the format   
					will toggle between mm/dd/yy and dd/mm/yy.   
					• Press Menu/OK [5] to save.   
					C. Selecting a Language   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					[SK:5] +   
					[SKToggle:a]   
					The soft key command will toggle between available languages. Alternate languages   
					can be uploaded to the receiver using the 3M™ Dynatel™ PCTools Software. The 3M™   
					Dynatel™ PC Tool Kit Software is available free of charge at www.3M.com/dynatel   
					under the Software section; 2550/2573/2250M/2273M/1420 Locator PC Tools xx.x.x   
					(EXE xx.xMB).   
					78-9000-0192-2 Rev C   
					17   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				D. Enabling/Disabling Locating Frequencies   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					Locate Freq [SK:f]   
					[SK:5] + >>More [SK:d] +   
					The user can select the frequencies that the receiver will detect. All the available   
					frequencies are listed in four groups (Left to Right: Active, Power, Passive, and   
					Auxiliary). The Auxiliary group also contains the User Defined Frequencies. (See 5G.   
					Creating User Defined Frequencies.) The box below the Auxiliary group allows the   
					selection of filtering for 50 Hz or 60 Hz passive signals when User Defined frequencies   
					have been chosen for locating.   
					• Press the right arrow [SK] to move the highlight   
					bar to the section of frequencies to enable, or   
					disable.   
					• Press the up/down arrows [SK] to highlight the   
					specific frequency.   
					• Press Enabl/Disabl [SK]. (Enable denoted by )   
					• Repeat steps 2 & 3 to enable/disable other   
					frequencies.   
					• Press Menu/OK [5] to save.   
					E. Selecting Locate Modes (Antenna Modes)   
					Menu/OK [5: Toggle to MAIN MENU] + More>> [SK:4] +   
					Modes [SK:e]   
					[SK:5] + More>> [SK:d] + Locate   
					The user can select the locate modes (antenna modes) that the receiver utilizes. There   
					are five locate modes that are available; Trace View (T-View), Directional Peak (Dir Pk),   
					Directional Null (DirNull), Special Peak (Spl Pk) and Induction Peak (Ind Pk).   
					All five modes are activated when shipped. The user can deactivate any of the modes   
					that will not be used.   
					• Press the up/down arrows [SK] to highlight a   
					specific locate mode in the first column.   
					• Press the right arrow [SK] to move the highlight   
					bar to the second column, or back to the first   
					column.   
					• Press Enabl/Disabl [SK]. (Enable denoted by )   
					• Repeat steps 2 & 3 to enable/disable other locate   
					modes.   
					• Press Menu/OK [5] to save.   
					18   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				F. Selecting External Jack Frequencies (Tone Frequencies)   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					>>More [SK:h] + Tone/Freq [SK:k]   
					[SK:5] + >>More [SK:d] +   
					A coupler can be plugged into the External Jack   
					[15] ([14] on 2550 locator) of the receiver and   
					used to identify 50 Hz or 60 Hz cables. (See 19.   
					Additional Applications: B: Cable Identification.)   
					The same procedure as above (Section 5D) is   
					followed for selecting frequencies that can be   
					detected by the External Jack [15] ([14] on 2550   
					locator) found on the bottom of the receiver.   
					G. Creating User Defined Frequencies   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					Locate Freq [SK:f]   
					[SK:5] + >>More [SK:d] +   
					There are four user defined frequencies available on the receiver. (These frequencies   
					must be between 50 Hz and 999 Hz.) These frequencies are found in the column on the   
					far right of the Locate Freq display (Auxiliary frequencies). These frequencies, once   
					programmed, will appear under the Aux [SK] frequency list when Freq [SK] is selected   
					in the Locate mode.   
					To program the user defined frequencies press the   
					right arrow [SK] to highlight the Auxiliary group   
					of frequencies. Press the up/down arrows [SK]   
					to highlight the user frequency to program. Press   
					Enabl/Disabl [SK].   
					Press the left/right arrows [SK] to move the square   
					cursor to a digit. Press Select [SK] to enter the   
					number in the frequency field.   
					Press Menu/OK [5] to save the programmed   
					frequency, or press Exit [SK] to cancel. The   
					frequency will appear in the locate frequency display   
					as U###, where ### represents the programmed   
					frequency.   
					Note: To redefine a previously programmed user   
					frequency, highlight the frequency, press enabl/   
					disabl, select the back arrow with the cursor, and   
					press select to delete the previous entry.   
					78-9000-0192-2 Rev C   
					19   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				H. Filtering Power Frequency Interference   
					(User Defined Frequencies Only)   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					Locate Freq [SK:f]   
					[SK:5] + >>More [SK:d] +   
					In order to filter out unwanted power influences   
					while locating with user-defined frequencies, verify   
					the correct frequency is selected for your location   
					(default 60 Hz). Press Menu/OK [5] to save.   
					I. Selecting Locating Audio   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					Audio Config [SK:g]   
					[SK:5] + >>More [SK:d] +   
					The user can choose the audio response of the   
					receiver when using the Directional Peak or Trace   
					View modes for path locating. Highlight the audio   
					selection and press Menu/OK [5] to save.   
					J. Adjusting Display Contrast   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					[SK:5] +   
					[SK:c]   
					The display contrast can be adjusted higher or lower.   
					• Press the solid circle [SK] to darken the display.   
					• Press the open circle [SK] to lighten the display.   
					• Press Menu/OK [5] to save.   
					20   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				6. Locating Buried Cables And Pipes   
					A. Transmitter Connections   
					Perform a battery test. Use one of the following three methods to produce a trace signal   
					on the target pipe or cable.   
					1. Direct Connect Method   
					! WARNING   
					This WARNING applies to the use of the Direct Connect Cables and the Transmitter.   
					To avoid potential shock, or electrically damaging the Transmitter, when setting up the   
					Transmitter to locate using the Direct Connect method, follow these basic steps;   
					• 
					ALWAYS plug the Direct Connect Cable into the Transmitter Output Jack [T-6] BEFORE   
					connecting the leads to the cable/pipe to be located and the ground rod.   
					– Connect the red lead to the cable/pipe.   
					– Connect the black lead to ground rod.   
					A POTENTIAL FOR ELECTRICAL SHOCK, AND/OR TRANSMITTER ELECTRICAL DAMAGE, EXISTS   
					WHEN USING THE DIRECT CONNECT CABLE ON CABLES ENERGIZED WITH ELECTRICAL POWER   
					IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED. USE APPROPRIATE SAFETY PROCEDURES.   
					CHECK VOLTAGE BEFORE CONNECTING TRANSMITTER. VOLTAGE HIGHER THAN 240 VOLTS WILL   
					DAMAGE EQUIPMENT. FOLLOW STANDARD PROCEDURES FOR REDUCING THE VOLTAGE.   
					• Plug the direct connect cable into the Output Jack [T-6] of the transmitter. Connect   
					the black clip to the ground rod. Place the ground rod in the earth perpendicular to   
					the suspected cable/pipe path. If necessary, extend the black lead with the Ground   
					Extension Cable (#9043 available separately).   
					• Remove the ground bonding and attach the red clip to the shield of the cable, pipe,   
					or target conductor. (If locating power cables, the red clip can be attached to the   
					transformer cabinet, or the meter box). Metal contact must be made between the red   
					clip and the transformer cabinet or meter box. If painted, some paint will need to be   
					removed/scraped off to allow metal-to-metal contact.   
					• Turn the transmitter on by pressing Ohms [T-2]. The continuity of the circuit will be   
					measured. The results are displayed on the Digital Display [T-4] in ohms and as an   
					audible tone.   
					78-9000-0192-2 Rev C   
					21   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				− If the continuity of the circuit is very good (the reading on the display is less than   
					3K Ω. and a solid tone from the transmitter is heard) all frequencies can be used to   
					locate. Always use the lowest frequency available (for example, 577 Hz). Lower   
					frequencies are less likely to ‘bleed over’ to other cables in the same area, and are   
					very good for tracing over long distances.   
					− If the circuit reads more than 3K Ω., but less than lOK Ω (indicated by a beeping   
					tone from the transmitter) it will be necessary to use a higher frequency than   
					577 Hz in order to locate the cable/pipe.   
					− If the circuit reads more than lOK Ω., it will be necessary to use an RF signal such   
					as 33 kHz, 82 kHz or 200 kHz.   
					− If there is no tone and the transmitter indicates that there is an open circuit (OL   
					in the display) this could be an indication of a poor ground, or an open-ended   
					cable or pipe. Use one of the higher frequencies available, at high or maximum   
					output power level. If it is an open-ended cable or pipe, the receiver's response will   
					decrease suddenly at the site of the clear or severed end.   
					Note: In the ohms mode, the transmitter can detect voltage as well as ohms. If a low   
					voltage is detected, the Digital Display [T-4] will alternate between displaying ohms   
					and volts. When displaying ohms, the flag over the Ω symbol will be visible. When   
					displaying volts, the flag over the ‘V' will be visible. When the voltage magnitude   
					is sufficient to impair the accuracy of the ohms measurement, only voltage will be   
					displayed. If the voltage is AC, a sine wave will be visible on the Digital Display [T-4].   
					If a high AC voltage is detected, a rapid beeping tone will be heard.   
					• Press Trace [T-3] repeatedly until the desired frequency appears on the display. Note   
					that the number that flashes alternately with the selected frequency is called the   
					relative current. This number can be useful in identifying the target cable/pipe and   
					is discussed more in 8. Depth and Current Estimate and 10. Locating in Directional   
					Peak Mode.   
					• Press Output Level [T-5] to select high, or maximum, output power level for longer   
					tracing distances or deep pipe/cable.   
					22   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				2. 3M™ Dyna-Coupler Method   
					! WARNING   
					This WARNING applies to the following 3M Dyna-Couplers;   
					• 3" (75 mm) - Part number 3001   
					• 4.5" (114 mm) - Part number 4001   
					• 6" (150 mm) - Part number 1196   
					• All accessory kits containing any of the listed Dyna-Couplers - Part numbers 3019, 4519,   
					1196/C   
					A potential for electrical shock exists when using the Dyna-Coupler on cables energized with   
					electrical power. Use appropriate safety procedures.   
					DO NOT USE ON CABLES CARRYING IN EXCESS OF 600 VOLTS RMS.   
					Use a ground extension cable,   
					or wire, and ground rod set-up   
					between a target pipe/cable and   
					a gas meter valve/box, or cable/   
					electrical meter box. This will isolate   
					the locate signal to the target pipe/   
					cable section below the meter/box,   
					between the grounding points. This   
					provides a good return path for the   
					tracing signal. Insulating coupling   
					above a gas meter valve on a pipe   
					will isolate the returning signal from   
					ground and may make locating   
					more difficult.   
					• Connect the Dyna-Coupler to the transmitter Output Jack [T-6] using the coupler   
					cable (9011).   
					• Clamp the Dyna-Coupler around the cable or pipe, below any bonds, just before it   
					enters the earth. The jaws of the coupler must fully close.   
					• Press Trace [T-3] to turn on the transmitter. Press again to select 8 kHz, 33 kHz,   
					82 kHz or 200 kHz.   
					Note: When using a Dyna-Coupler, always select high, or maximum, output power   
					level by pressing Output Level [T-5] key on the transmitter.   
					78-9000-0192-2 Rev C   
					23   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3. Induction Method   
					If you cannot make a direct connection, or use the 3M™ Dyna-Coupler clamp to apply a   
					locating signal on the target, use the induction method. When nothing is plugged into the   
					Output Jack [T-6] of the transmitter the unit will be placed into induction mode when it   
					is turned on. This method uses the internal coil of the transmitter to generate a magnetic   
					field. This is the least preferred method of applying a signal on a target conductor   
					because it can easily be picked up by other non-target conductors in the area. However,   
					it is the preferred method of applying a signal to multiple cables/pipes in the same trench   
					and for the “two-person sweeping” application.   
					3M Dynatel™ transmitters provide a choice of induction frequencies and output power   
					levels. Higher induction output power levels are needed for detecting deeper depths   
					and longer ranges. The 2500 Series transmitters provide four induction frequencies:   
					8 kHz, 33 kHz, 82 kHz and 200 kHz and three output power settings up to 12W. The   
					82 kHz and 200 kHz frequencies are commonly used for deeper cables/pipes and the   
					lower frequencies are used to give longer locate distances. The 8 kHz (low frequency)   
					induction helps in locating shallow facilities, such as risers.   
					The following sections review Non-sweeping and Sweeping (Area) methods used   
					with the Induction Mode. The Non-Sweeping method is utilized when a specific target   
					requires path tracing. The transmitter remains stationary in-line over the target and the   
					path is traced. The Sweeping method is utilized when a designated area needs to be   
					swept for non-specific targets, for example, all the buried pipes or conductors in the   
					designated area. Several sweeping methods will be reviewed.   
					A. Non-Sweeping(Passive) Induction Mode Locating   
					• Position the transmitter over the target facility, with the hinge of the transmitter over   
					and in line with the cable/pipe path. Remove any cables from the Output Jack [T-6].   
					− Align the Induction Direction arrows on the transmitter with the target conductor.   
					• Turn on the transmitter, select the frequency and select high output or maximum   
					output power level for best signal-to-noise ratio.   
					• Trace the signal path with the receiver using the Induction Peak (Ind Pk) mode.   
					The Induction Peak (Ind Pk) mode of the receiver is a mode in which the upper antenna   
					of the receiver is tuned to minimize distortion from the magnetic field of the transmitter.   
					Use Induction Peak (Ind Pk) mode when sweeping distance between the transmitter and   
					receiver is 25–60 feet (7.6–20 m). Beyond 60 feet (20 m) you can also use the Special   
					(single) Peak (Spl Pk) or Directional Peak (Dir Pk) modes. Special (single) Peak (Spl   
					Pk) can be used for maximum detection depth and range (needed for deep conductors   
					and metal pipes), but would require increased sweep distance separation between the   
					transmitter and receiver.   
					24   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Note: If nothing is plugged into the Output Jack [T-6] of the transmitter, the   
					transmitter will automatically turn on the internal antennae, and the last frequency   
					used (8 kHz, 33 kHz, 82 kHz or 200 kHz) will broadcast in induction mode.   
					The induction frequency can be changed by pressing the Trace [T-3] (Frequency [T-3]   
					on 2550) button on the transmitter. For best results, the receiver should be at least 25   
					feet (7.6 m) away from the transmitter to begin tracing the target path, have the gain   
					set between 78-84% and have the receiver in Induction Peak (Ind Pk) mode when   
					starting the sweep. Attempting to trace the target close to the transmitter may lead to   
					false indications due to the receiver detecting the large magnetic field radiating from   
					the transmitter.   
					B. Sweeping (Active) Induction Mode Locating   
					Sweeping an area with the 3M™ Dynatel™ Locator 2500 Series allows the location of   
					multiple metallic cables and pipes buried in an area without direct connect or coupler   
					access to the cable or pipe. This approach is effective before any excavation takes place.   
					Note that when specific buried objects need to be identified, it's important to use the   
					direct connect or coupler method for applying the signal. This will help limit the applied   
					locate signal to a specific facility that provides more position and depth accuracy along   
					with an effective identification. There are two main types of “no access” or “blind”   
					Induction Sweeps;   
					Passive Sweeps: These require only the use of the Receiver with passive frequency   
					detection capability. This method uses existing external signal sources, such as 60 Hz/50   
					Hz for electric power, 15 kHz to approximately 30 kHz for low frequency radio signals,   
					120 Hz / 100 Hz CPS for impressed current Cathodic Protection signals and the less   
					commonly occurring CATV signal of 31.25 kHz NTSC with CRT TV turned on.   
					Active Sweeps: These require both the Receiver and Transmitter with Induction   
					capability. This method refers to using a 3M Dynatel transmitter as the signal source   
					through induction, instead of relying on passive frequencies that may exist on the   
					buried conductor or metal pipe. Active Induction allows for detecting buried cables   
					and metal pipes in the absence of passive signals and at deep depths and short sections.   
					3M Dynatel transmitters provide a choice of induction frequencies and output power   
					levels. Higher induction output power levels are needed for detecting deeper depths   
					and longer ranges. The 2500 Series transmitters provide four induction frequencies: 8   
					kHz, 33 kHz, 82 kHz and 200 kHz and three output power settings up to 12W. The 82   
					kHz and 200 kHz frequencies are commonly used for deeper cables/pipes and the lower   
					frequencies are used to give longer locate distances.   
					C. Passive Sweeps   
					Select Special (single) Peak (Spl Pk) mode on the receiver and then select the frequency   
					(source; for example, power, LF, etc.) to be traced. Passive sweeps at power frequency   
					will detect buried power cables and conductors carrying 60 Hz/50 Hz power signal in the   
					ground. Other passive sources exist, such as Cathodic Protection, LF and CATV cable   
					(with NTSC TV CRT turned on).   
					78-9000-0192-2 Rev C   
					25   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Walk in a grid pattern over the sweep area holding the receiver as shown in the   
					following illustration. Stop when there is a response increase, locate the position of the   
					maximum signal, follow the conductor path all the way out of the sweep area while   
					putting location marks on the ground. Resume the sweep until another cable or pipe is   
					detected, or the whole area is completely swept. Switch to another available passive   
					frequency in the receiver and sweep again.   
					D. One-person Active Induction Mode Sweeps   
					One-person active induction mode sweeps require that the transmitter be set on the   
					ground over the suspected path of the buried infrastructure. The receiver is used to   
					detect signals induced by the transmitter on buried long conductors. Proper placement   
					and orientation is key to maximize the induced signal in the buried cable or metallic   
					pipe enough to be detectable by the receiver along each path in the swept area. (Note   
					that no signal is induced onto a conductor whose path is perpendicular to the Induction   
					Direction indication.)   
					• Place the transmitter in the upright (bottom on ground) position for directional   
					optimization when aligned with the Induction Direction shown on the label on the   
					transmitter.   
					• Tip the transmitter over towards the front, and lay it on it's front surface, for multi-   
					directional wide area induction. (Note that no signal is induced onto a conductor   
					whose path is directly under the transmitter).   
					• Remove anything plugged into the Output Jack [T-6] (this will place unit in Induction   
					Mode), select highest available frequency (200 kHz) and highest output power level.   
					• Select the Induction Peak (Ind Pk) mode and 200 kHz frequency on the receiver.   
					When in close proximity to the transmitter in induction mode, there is a direct signal   
					from the induction antenna in the transmitter to the receiver through the air. Induction   
					Peak (Ind Pk) mode is a newly added locate mode for use in closer proximity to a   
					transmitter in Induction mode (<60 ft , 20 m typ.). Special (single) Peak (Spl Pk)   
					would give the highest sensitivity, but is affected by the air signal more than Induction   
					Peak (Ind Pk) mode.   
					26   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				E. Two-person Active Induction Mode Sweeps   
					In two-person active induction mode sweeps, one person holds the transmitter and   
					the other holds the receiver while walking together in a sweep pattern detecting long   
					conductors in the ground when crossed by transmitter and receiver positions and   
					orientation, as shown below:   
					Transmitter Set-up   
					• Remove anything plugged into the Output Jack [T-6] (this will place unit in Induction   
					Mode), select high frequency (200 kHz), or medium frequency (33 kHz or 82 kHz),   
					and highest output power level.   
					• Hold the transmitter with the lid facing up and align it with the Induction Direction   
					arrow label, as shown on the transmitter, with the receiver   
					Receiver Set-up   
					• Set the receiver to the same frequency as the transmitter.   
					• Select the Induction Peak (Ind Pk) mode, and press the Gain [3] (+ or -) key until the   
					Bar Graph [11] ([10] for 2550) is just visible.   
					Sweeping   
					• Sweeping can be done at close distances between the transmitter and receiver.   
					• For best results, the receiver should be at least 25 feet (7.6 m) away from the   
					transmitter to begin tracing the target path and have the gain set between 78-84%   
					when starting the sweep. Attempting to trace the target close to the transmitter may   
					lead to false indications due to the receiver detecting the large magnetic field radiating   
					from the transmitter.   
					• Induction Peak (Ind Pk) mode cancels the air signal coming directly from the   
					transmitter induction antenna to the receiver. Increasing the sweep distance between   
					the transmitter and receiver reduces the direct air signal and allows for sensing deeper   
					conductors and sections of metal pipes. Use Induction Peak (Ind Pk) mode when   
					sweeping distance between the transmitter and receiver is 25–60 feet (7.6–20 m).   
					Beyond 60 feet (20 m) you can also use the Trace View (T-view), Special (single)   
					Peak (Spl Pk) or Directional Peak (Dir Pk) modes.   
					• Special (single) Peak (Spl Pk) can be used for maximum detection depth and range   
					(needed for deep conductors and metal pipes), but would require increased sweep   
					distance separation between the transmitter and receiver.   
					78-9000-0192-2 Rev C   
					27   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				7. Receiver Locating Trace Modes   
					A. Trace View (T-View)   
					TRACE [2]   
					Trace View mode, or T-View, provides an intuitive mapping display showing the utility   
					path utilizing a dynamic directional arrows and path indication line. This combination   
					provides an excellent visual representation of the utility path and directional assistance   
					to assist in pinpointing the target.   
					Several displays may be seen when using Trace View:   
					Display 1. When the receiver is outside of the detectable locating signal range, the   
					display will show a solid circle inside of a dotted circle. At times it may   
					show the dynamic directional arrow shown in Display 2 and/or the image   
					in Display 4 below. The images may flash alternately indicating that the   
					receiver is out of detectable locating signal range. See following example;   
					Display 2. When the receiver is within the detectable locating signal on the target, a   
					steady target line will appear on the receiver display representing the target.   
					The dynamic directional display arrows will guide the operator towards the   
					target. The receiver volume and the signal strength increase as the target is   
					approached. See following examples;   
					Left of Target Path   
					Right of Target Path   
					28   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Display 3. As the receiver antenna crosses the target, the receiver volume increases to   
					a maximum, the signal strength will be at its maximum and the directional   
					arrow will become a straight line that is closely lined up with the target line   
					on the display. See following examples;   
					On Target Path   
					Display 4. A circle consisting of two arrows appears when the orientation of the receiver   
					is not at the optimum position in relation to the target. The arrows indicate   
					that the receiver should be twisted to obtain the optimum position. See   
					following examples;   
					Twist Receiver   
					B. Special Peak (Spl Pk)   
					TRACE [2] + Mode [SK] + Spl Pk [SK Toggle] or   
					Menu/OK [5] + Cable/Pipe [SK] + Mode [SK] + Spl Pk [SK Toggle]   
					Special Peak mode turns on only the peak antenna closest to the ground. Special Peak   
					Mode is used in applications such as very deep cables or pipes, or when the signal is too   
					weak for Directional Peak (Dir Pk) or Trace View (T-View) mode tracing.   
					Left or Right of Target Path   
					Directly Over Target Path   
					C. Induction Peak (Ind Pk)   
					TRACE [2] + Mode [SK] + Ind Pk [SK Toggle]   
					or Menu/OK [5] + Cable/Pipe [SK] + Mode [SK] + Ind Pk [SK Toggle]   
					If you cannot make a direct connection, or use the 3M™ Dyna-Coupler clamp to apply   
					a locating signal on the target, use the induction method. This method uses the internal   
					coil of the transmitter to generate a magnetic field.   
					78-9000-0192-2 Rev C   
					29   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				The Induction Peak mode of the receiver is a mode in which the upper antenna of the   
					receiver is tuned to minimize distortion from the magnetic field of the transmitter.   
					Left or Right of Target Path   
					Directly Over Target Path   
					D. Directional Peak (Dir Pk)   
					TRACE [2] + Mode [SK] + Dir Pk [SK Toggle]   
					or Menu/OK [5] + Cable/Pipe [SK] + Mode [SK] + Dir Pk [SK Toggle]   
					In Directional Peak mode, four peak antennas are used to analyze the magnetic field   
					pattern. The bar graph indicates signal strength and the directional arrows sense the   
					edges of the magnetic field. The left/right arrows will indicate the direction to the nearest   
					cable/pipe that is in-line with the receiver handle.   
					As the antenna crosses the cable or pipe, the receiver speaker volume increases to a   
					maximum, the Bar Graph [1l] ([10] for 2550 locator) fills from both sides toward the   
					middle, and the numeric Signal Strength [9] ([8] for 2550 locator) increases. As the   
					antenna moves off the target path, the speaker volume decreases and the Bar Graph [1l]   
					([10] for 2550 locator) opens. Use the Bar Graph [1l] ([10] for 2550 locator) and the   
					numeric Signal Strength [9] ([8] for 2550 locator) to locate the exact target path.   
					Left of Target Path   
					Directly Over Target Path   
					Right of Target Path   
					Once the target path has been located, the arrows at the top of the display will indicate   
					the location of the target path in relationship to the receiver handle.   
					Note: When field distortion (due to congestion) is affecting the receiver, the left/right   
					arrows may not coincide with the bar graph. Use the maximum numerical Signal   
					Strength [9] ([8] for 2550 locator) to target the cable or pipe.   
					30   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				E. Directional Null (DirNull)   
					TRACE [2] + Mode [SK] + DirNull [SK Toggle]   
					or Menu/OK [5] + Cable/Pipe [SK] + Mode [SK] + DirNull [SK Toggle]   
					In Directional Null mode, as the operator approaches the cable or pipe, the numerical   
					Signal Strength [9] ([8] for 2550 locator) will increase then fall sharply as the receiver   
					crosses the target cable or pipe. The Bar Graph [11] ([10] for 2550 locator) fills from   
					both sides toward the middle and the receiver speaker volume decreases. As the antenna   
					moves off the target path, the Bar Graph [11] ([10] for 2550 locator) opens, the Signal   
					Strength [9] ([8] for 2550 locator) increases, and the speaker volume increases. Gain   
					adjust is automatic in Directional Null mode.   
					The center of the DirNull display provides a ‘compass view' of the target path. An arrow   
					will point toward the location of the cable/pipe in 45-degree steps. A solid line will   
					appear over the cable/pipe, indicating its orientation to the receiver handle.   
					For example:   
					Figure 1: If the target path is to the right of the   
					receiver, and running parallel to the operator, the   
					right arrow will display.   
					Figure 2: If the target path is to the left and in front   
					of the operator (not running parallel to the receiver)   
					the arrow will point toward the top left side of   
					the display.   
					Figure 3: When the receiver crosses the target path,   
					a solid line will appear, instead of arrows, indicating   
					the target path and its orientation to the receiver   
					handle.   
					Before marking target path, always use Directional Peak (Dir Pk), Special Peak (Spl Pk)   
					or Trace View (T-View) mode to verify location.   
					78-9000-0192-2 Rev C   
					31   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				F. Expanded Mode   
					VOL [13] (press up arrow)   
					When the third ring of the speaker icon is dotted   
					or broken and ‘xpnd’ appears below the speaker   
					icon as shown, the receiver is in “Expanded”   
					mode. This mode is used for pinpointing a   
					target cable or pipe. The area of response of the   
					receiver narrows, allowing the locator to detect   
					very small signal changes. Press the Speaker   
					Volume Control [13] ([12] for 2550 locator) key   
					to activate the "Expanded" mode.   
					8. Depth and Current Estimate   
					Verifying the target path, depth and current can be helpful tools.   
					• Pinpoint the cable or pipe being located.   
					• Lower the tip of the receiver to the ground and   
					press DEPTH [4].   
					− The depth to the target cable or pipe is displayed   
					in the units specified in the receiver set up   
					menu. The bold current reading is the relative   
					current measurement. This reading can be   
					compared to the relative current reading that   
					alternately flashes with the frequency on the   
					transmitter to help identify the target cable/pipe.   
					The highest relative current value will be the   
					target cable/pipe and will compare closest to the   
					transmitter relative current value. The milliamp   
					reading is an actual current measurement.   
					− There are two options for measuring depth.   
					Live depth is a continuous measurement. 1-Shot   
					Depth is an averaging of the depth reading over   
					a short period of time. When in 1-Shot mode,   
					the unit will average the depth reading for three   
					seconds, and then display the result on the   
					display. Press DEPTH [4] to alternate between   
					the two modes.   
					− Five depth readings can be saved with the time,   
					date and relative current measurements.   
					• Pressing Mem Select [SK] and then Save [SK] will place each entry in sequential   
					order in memory (M1–M5) until five readings have been stored. The unit will   
					overwrite saved entries in excess of five, beginning with M1.   
					32   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				• Optional step: Press Clear All [SK] to delete all   
					stored depth information.   
					− The operator may select a specific memory   
					location to store the depth readings by pressing   
					Mem Select [SK]. When the preferred location   
					appears on the display, press Save [SK]. The   
					display and memory location will populate with   
					the current information.   
					− Each memory location can be reviewed by   
					pressing Mem Select [SK].   
					• Press TRACE [2] or DEPTH [4] to return to Locate   
					mode, or wait until receiver automatically returns   
					to the Locate mode.   
					9. Locating Frequencies   
					A. Active Frequencies   
					Active frequencies are trace signals supplied by a 3M™ Dynatel™ Transmitter 2500   
					Series (577 Hz, 1 kHz, 8 kHz, 33 kHz, 82 kHz or 200 kHz).   
					• Select the same frequency that the transmitter is generating.   
					• Press Menu/OK [5] (you may have to press Menu/OK [5] twice to toggle to the   
					LOCATE MENU display).   
					• Press Cable/Pipe[SK]   
					• Press Freq [SK]   
					• Press Active [SK Toggle] until the desired frequency is displayed: (“Active” 577, 1k,   
					8k, 33k, 82k or 200k)   
					• Press Menu/OK [5] to return to Locate mode.   
					B. Power Frequencies   
					Power frequencies refer to 50 or 60 Hz signals, and their harmonics, that can be traced   
					without the use of a transmitter.   
					60: Best for general locating of passive power.   
					60H (high harmonic): If the 60 choice appears to be responding slowly, or poorly, then   
					60H is the second choice for locating passive power.   
					60L (low harmonic): Third choice for passive power locating. May be used when 60 or   
					60H is weak or erratic. 60L may be the best choice when locating primary power cables.   
					120 Hz: Used for locating rectified AC power signals, often found on pipelines using   
					impressed current cathodic protection.   
					• Press Menu/OK [5] (you may have to press Menu/OK [5] twice to toggle to the   
					LOCATE MENU display).   
					78-9000-0192-2 Rev C   
					33   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				• Press Cable/Pipe[SK]   
					• Press Freq [SK]   
					• Press Power [SK Toggle] until the desired frequency is displayed: (“Power” 60, 60L,   
					60H, or 120).   
					• Press Menu/OK [5] to return to Locate mode.   
					All U.S. receivers default to 60 Hz.   
					To set the receiver to detect 50 Hz signals refer to 5.D. Enabling/Disabling Locating   
					Frequencies section of this manual.   
					C. Passive Frequencies   
					The receiver (without a 3M™ Dynatel™ Transmitter 2500 Series) can be used to detect   
					some CATV cables (31.5 kHz). (A horizontal-scan television NTSC must be turned on to   
					generate this frequency.)   
					• Press Menu/OK [5] (you may have to press Menu/OK [5] twice to toggle to the   
					LOCATE MENU display).   
					• Press Cable/Pipe [SK]   
					• Press Freq [SK]   
					• Press Pasv [SK Toggle]   
					• Press Menu/OK [5] to return to Locate mode.   
					D. Auxiliary Frequencies   
					Auxiliary frequencies are signals generated from remote location transmitters, or   
					frequency generating transmitters.   
					• Press Menu/OK [5] (you may have to press Menu/OK [5]twice to toggle to the   
					LOCATE MENU display).   
					• Press Cable/Pipe [SK]   
					• Press Freq [SK]   
					• Press Aux [SK Toggle] until the desired frequency is displayed; (“Aux” 512, 560,   
					333 Hz, or user defined frequencies).   
					• Press Menu/OK [5] to return to Locate mode.   
					34   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				10. Locating in Directional Peak Mode   
					The following are instructions for locating a buried pipe or cable using the direct connect   
					method and the Directional Peak (Dir Pk) mode. Other methods of connection and   
					tracing modes/features are explained in previous sections.   
					Step 1. Insert the ground rod into the ground, perpendicular to the suspected target   
					path.   
					Step 2. Remove the grounding from the near-end of the target cable/pipe.   
					Note: Never connect or disconnect the transmitter when the unit is on.   
					Step 3. Connect the red lead of the transmitter to the shield, neutral, or deenergized   
					target conductor.   
					Step 4. Connect the black lead of the transmitter to the ground rod.   
					Step 5. Perform a battery check by pressing and holding off [T-1].   
					Step 6. Power on the transmitter by pressing on [T-2] once. This will place the   
					transmitter in Ohm-meter mode. An Indicator Flag will be displayed above the   
					ohm symbol, Ω, in the Digital Display [T-4].   
					a. A solid tone from the transmitter indicates a complete circuit with a good   
					ground.   
					b. A beeping tone from the transmitter indicates a usable ground. An attempt   
					should be made to improve the ground.   
					c. No tone from the transmitter indicates a poor, or no ground. The transmitter   
					will display ‘OL’ in this instance. An attempt should be made to improve the   
					ground. Verify that the far end is grounded.   
					Step 7. Press on Trace (Frequency on 2550 locator) [T-3] to set the transmitter to Trace   
					mode.   
					Step 8. Select a frequency on the transmitter by pressing Trace (Frequency on 2550   
					locator) [T-3]. The unit will cycle through the available frequencies (577, 1K,   
					8K, 33K, 82K, 200K and ALL).   
					Step 9. Press On/Off [1] to power on the receiver.   
					Step 10. Press Menu/OK [5] (you may have to press Menu/OK [5] twice to toggle to the   
					LOCATE MENU display).   
					Step 11. Press Cable/Pipe [SK].   
					78-9000-0192-2 Rev C   
					35   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 12. Set the Frequency and Mode of the receiver.   
					a. Press Freq [SK]   
					b. Select the same frequency on the   
					receiver that was selected on the   
					transmitter by pressing Active [SK   
					Toggle].   
					c. Press Menu/OK [5] to save the setting   
					and return to Locate mode.   
					d. Press Mode [SK Toggle] until Dir Pk is   
					displayed.   
					Step 13. Stand away from the suspected target path and adjust the Gain [3] down until   
					the Bar Graph [11] ([10] for 2550 locator) opens completely.   
					Step 14. Walk in a wide circle with your back toward the transmitter (about 10 to 15 feet   
					(3 to 4.5 m) away).   
					− Watch the receiver display and listen to the signal. Take note of where the   
					receiver detects the strongest Signal Strength [9] ([8] for 2550 locator).   
					− The Bar Graph [11] ([10] for 2550 locator) will close when the unit detects   
					a signal, and the arrows will reverse.   
					− Adjust the Gain [3] down if the Bar Graph [11] ([10] for 2550 locator)   
					closes completely.   
					− The Signal Strength [9] ([8] for 2550 locator) numbers on the display will   
					change with the signal strength (smaller, as you walk away from the target   
					path; larger, as you approach the target path).   
					− Make a complete circle around the transmitter. Return to each point in the   
					circle that the receiver detected.   
					Step 15. Measure the Depth and Current of each point to identify the target path. The   
					depth of the target path should be as expected and the relative current should   
					compare to the relative current that is alternately flashing with the frequency   
					value on the transmitter.   
					Note: The Relative Current reading will decrease steadily as the locator moves away   
					from the transmitter. When using higher frequencies, this decline is more evident.   
					Step 16. Adjust the gain so that the Bar Graph [11] ([10] for 2550 locator) responds to   
					the target path (open when off path, almost completely closed when directly   
					over target).   
					Step 17. Trace the cable/pipe at a slow walk while moving the receiver in a side-to-side   
					motion, keeping the receiver perpendicular to the ground.   
					36   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 18. Measure the Depth and Current occasionally to verify target path.   
					Note: In order to measure the Depth and Relative Current accurately, the operator   
					must pinpoint the target pipe or cable, and the receiver handle should be in-line with   
					the target path.   
					− While in Dir Pk mode, find the highest Signal Strength [9] ([8] for 2550   
					locator).   
					− Lower the tip of the receiver to the ground. Twist the receiver left and right   
					while watching the Signal Strength [9] ([8] for 2550 locator).   
					− When the highest reading is displayed, the handle of the unit is in line with   
					the target pipe or cable.   
					Occasionally a signal will appear on adjacent cables or pipes. Compare the   
					relative and actual current readings (value that is under the relative current   
					value and in mA units) over each path to help determine the target path. Current   
					readings will be significantly less on the adjacent cable/pipe compared to the   
					target path.   
					Step 19. As tracing proceeds, remember that the most powerful signal is near the   
					transmitter. As the receiver gets farther away from the transmitter the Signal   
					Strength [9] ([8] for 2550) decreases. It may be necessary to readjust the gain   
					as needed to be sure there is adequate signal for the receiver to operate. Press   
					the Gain [3] up or down when the Bar Graph [11] ([10] for 2550 locator) is   
					no longer visible (too little signal) or when the Bar Graph [11] ([10] for 2550   
					locator) is closed (too much signal).   
					Step 20. Trace the path until you reach a logical termination point (i.e.: terminal, meter,   
					cabinet, etc).   
					11. Locating Active Duct Probes (Sondes)   
					Step 1. Press On/Off [1] on the receiver.   
					Step 2. Press Menu/OK [5] (you may have to press Menu/OK [5] twice to toggle to the   
					LOCATE MENU display).   
					Step 3. Press Cable/Pipe [SK].   
					Step 4. Press Mode [SK Toggle] to select Special Peak (Spl Pk).   
					Step 5. Press Freq [SK].   
					Step 6. Press Active [SK Toggle] to select the 33kHz frequency (for a 33 kHz Sonde   
					or ADP (Active Duct Probe)).   
					Step 7. Press Menu/OK [5].   
					78-9000-0192-2 Rev C   
					37   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 8. With the receiver handle perpendicular to the conduit path, locate the ADP   
					position by moving along the path until the strongest Signal Strength [9] ([8]   
					for 2550 locator) is found. Adjust Gain [3] up or down when the Bar Graph   
					[11] ([10] for 2550 locator) remains either fully open or fully closed.   
					Step 9. Refer to the ADP operating instructions for further information.   
					A. Determining Active Duct Probe Depth   
					Step 1. Place the tip of the receiver on the ground directly above the located ADP   
					position.   
					Step 2. Maintain the handle orientation perpendicular to the target path.   
					Step 3. Press DEPTH [4].   
					Step 4. Press Sonde Depth [SK] to read ADP Depth.   
					− The depth to the ADP is displayed in   
					units as specified in the receiver set up   
					menu.   
					− Five Sonde depth readings can be saved   
					with the time and date measured. Press   
					Mem Select [SK] after the Sonde depth   
					displays.   
					− Press Mem Select [SK] to select a   
					specific memory location (M1–M5) or   
					select Save [SK]. Save [SK] will place   
					each entry in sequential order in memory   
					(M1–M5) until five readings have been   
					stored. The unit will overwrite saved   
					entries in excess of five, beginning   
					with M1.   
					Step 5. Optional step: Press Clear All [SK] to delete all saved depth readings.   
					Step 6. Press Mem Select [SK] to select a specific memory location (M1 - M5) to store   
					the depth readings.   
					Step 7. When the preferred location appears on the display, press Save [SK]. The   
					display and memory location will populate with the current information.   
					Step 8. Each memory location can be reviewed by pressing Mem Select [SK].   
					Step 9. Press Cable Depth [SK] to switch to the cable depth display, or Menu/OK [5] to   
					return to Locate Mode.   
					Note: During a depth measurement, the display will exhibit ‘- -’ when the received   
					signal is too low, too high or erratic.   
					38   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				12. Locating Buried Sheath Faults And Earth   
					Return Faults   
					(3M™ Dynatel™ Models 2573 and 2573-iD only)   
					Note: Remove (disconnect) both the near-end and far-end grounding from the test   
					section.   
					A. Transmitter Setup   
					Note: Do not make any connections while the transmitter is on. Fault location will not   
					work unless the near-end and far-end grounds are disconnected.   
					Note: This method only works on direct buried cables/conductors. It will not work if   
					the cables/conductors are faulted inside of a conduit, such as a PVC conduit.   
					Step 1. Attach the red clip to the earth-faulted conductor of the cable or conductor   
					under test.   
					Step 2. Place the ground rod behind the transmitter and in parallel with the target path.   
					Step 3. Connect the black clip to the ground rod behind the transmitter.   
					Step 4. Press and hold On/Off [1] to perform a battery test.   
					Step 5. Press on [T-2] once to power on the transmitter. This will place the transmitter   
					in Ohm-meter mode. An Indicator Flag will be displayed above the ohm   
					symbol, Ω, in the Digital Display [T-4].   
					− The resistance of the fault will be displayed in ohms on the transmitter   
					Digital Display [T-4].   
					− Resistance less than 50KΩ = Significant fault exists   
					− Resistance 50KΩ to 1.0MΩ = High resistance fault exists (May or may not   
					cause problems yet, but gets worse with time.)   
					− Resistance greater than 1.0MΩ = No significant fault exists   
					Note: The fault locating limit is 2.0MΩ, although the transmitter's ohm-meter mode   
					can display a fault resistance up to 10MΩ.   
					Step 6. Press on [T-2] again, to select Fault mode.   
					− An Indicator Flag will be displayed above the fault locating symbol in the   
					Digital Display [T-4]. (as shown in the illustration below)   
					TM   
					Dynatel 2573   
					Trace   
					- 
					+ 
					o 
					Output Level   
					off   
					on   
					Flag   
					Note: Two active line locating frequencies, 577 Hz and 33 kHz, are simultaneously   
					transmitted with the fault finding signal. This allows convenient switching back and   
					forth between fault finding mode and cable/pipe locate mode on the receiver during   
					fault finding without returning to the transmitter. The transmitter display [T-4] will   
					flash between 577 Hz and 33 kHz. It does not display the fault finding frequencies.   
					78-9000-0192-2 Rev C   
					39   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				B. Pinpointing the Buried Fault   
					Step 1. Connect the 3M™ Earth Contact Frame to the External Jack [15] ([14] for 2550) of   
					the receiver using the Earth Contact Frame cable (4 ft. (1.2 m) cable).   
					Step 2. Press On/Off [1] to power on the receiver. The receiver display screen will   
					display "Fauly Calibrating" for about 5 seconds.   
					Step 3. Press Menu/OK [5].   
					Step 4. Press Fault [SK] to select Fault mode.   
					Step 5. Hold the receiver in one hand and the Earth Contact Frame in the other with the   
					solid green-banded leg of the frame toward the test section. Near the location   
					of the ground rod (about one Earth Contact Frame width away from the ground   
					rod, slightly to the side and towards the faulted cable.), insert the Earth Contact   
					Frame probes fully into the ground in line with the target path.   
					Step 6. Press REF [SK] to record the fault Signal Strength [9] ([8] for 2550 locator)   
					level reference. The signal level will be recorded in the box above REF [SK]   
					on the display. This reference indicates the Signal Strength [9] ([8]) for 2550   
					locator) level at the ground rod. When the operator reaches the major fault   
					location, the Signal Strength [9] ([8]) for 2550 locator) indicated on the receiver   
					will be very close (within 12dB) to this reference signal strength level.   
					Step 7. Continue along the cable path, re-inserting the Earth Contact Frame probes   
					every few steps while watching the receiver bar graph. The bar graph on the   
					receiver will fill toward the right side of the display (green Fault Finding   
					Direction Indicator [8] (See illustration below)), indicating that the fault is   
					ahead of the operator (in the direction of the green-banded leg of the Earth   
					Contact Frame).   
					Move in direction of green-banded leg   
					Move in direction of red-banded leg   
					of 3M™ Earth Contact Frame.   
					of 3M™ Earth Contact Frame.   
					Green Band   
					Red-and-White-Striped Band   
					Transmitter Signal   
					Ground Fault location   
					40   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 8. When the bar graph fills toward the left (red-and-white-striped Fault Finding   
					Direction Indicator [8] (See illustration above.)) side of the display, the fault   
					has been passed and is now behind the operator. Move back, inserting the   
					3M™ Earth Contact Frame every few inches, until the arrows alternate back to   
					green. Mark the point beneath the center of the Earth Contact Frame. Turn the   
					Earth Contact Frame 90 degrees and insert into the ground over the previously   
					marked point. Move the Earth Contact Frame to the left and right (following   
					the directions of the green and red indicator arrows). When the arrows reverse a   
					third time, turn the Earth Contact Frame 90 degrees again. Pinpoint the fault by   
					moving the Earth Contact Frame in the direction of the green and red indicator   
					arrows. The fault is located beneath the center of the Earth Contact Frame when   
					the arrows change from one side to the other this time.   
					Step 9. To verify the fault location, insert the Earth Contact Frame’s red-and-white-   
					striped probe directly on the spot identified above. Pivot the Earth Contact   
					Frame in a circle around the red-and-white-striped leg re-inserting the green-   
					banded leg in the ground every few degrees of the circle (See figure below).   
					The arrow should always point toward the left (red) indicating that the fault is   
					directly below the red-and-white-striped leg.   
					Step 10. After a fault is located and pinpointed, move the Earth Contact Frame about   
					one Earth Contact Frame width away from the fault and insert it in the ground   
					with the green-banded leg towards the fault. Compare the numeric signal   
					level with the fault signal strength level reference indicated in the lower left   
					box labeled REF. If the reading is within 12 dB of the fault signal strength   
					reference, the operator has found the major fault. If the fault reading does not   
					fall within 12 db of the fault signal strength reference reading, multiple faults   
					may exist. The signal level of this secondary fault can be saved by pressing   
					Fault 1 [SK] or Fault 2 [SK]. The fault with the highest reading will be the   
					primary fault.   
					Note: For additional information about locating buried sheath faults and earth   
					return faults, please see the 3M™ publication Cable and Pipe Locating Techniques at   
					
					78-9000-0192-2 Rev C   
					41   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				13. Locating 3M™ Electronic Markers and 3M™ iD   
					Markers   
					(3M™ Dynatel™ Models 2550-iD and 2573-iD only)   
					A. Enabling/Disabling Marker Types   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					[SK:h] + Marker Type [SK:j]   
					[SK:5] + >>More [SK:d] + >>More   
					The unit will default with all markers enabled ().   
					Step 1. Press the up/down arrows [SK] to highlight   
					a utility to enable or disable.   
					Step 2. Press Enabl/Disabl [SK].   
					− Only the markers that are enabled ()   
					will be available in the locate mode.   
					Step 3. Press Menu/OK [5] to save settings or   
					Exit [SK] to cancel.   
					B. Alert Mode   
					While tracing a cable or pipe, it is possible to search for iD markers.   
					Step 1. Press Alert [SK].   
					− If the unit is in Dir Pk, DirNull, Ind   
					Pk or T-View modes, a prompt will   
					notify the operator that alert mode only   
					functions in Special Peak (Spl Pk) mode.   
					Step 2. Press Mode [SK Toggle] for Spl Pk.   
					Step 3. Press Alert On [SK Toggle].   
					− The receiver display will add the Alert   
					bar graph and the type of marker to   
					the display with a prompt to adjust the   
					marker gain. (Note: The marker utility   
					type will default to the last utility type of   
					marker selected in Marker Locate mode.   
					To change the utility type of marker to   
					locate see Step 6 below.)   
					Step 4. Press the Gain [3] until only a small mark   
					on the marker bar graph is visible.   
					Step 5. Press Menu/OK [5] to save the marker gain   
					setting.   
					42   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				− The display will return to Special Peak   
					(Spl Pk) Cable Locate / Alert On.   
					− If the selected type of utility marker is   
					detected, a second audio tone will emit   
					from the unit and the marker bar graph   
					will fill.   
					Step 6. To change the type of marker that the unit   
					will detect in alert mode:   
					− Press Menu/OK [5] + Marker [SK] +   
					Markr1 [SK Toggle].   
					− Select appropriate Marker utility by   
					pressing Markr1 [SK Toggle].   
					− Press Menu/OK [5].   
					− Press Cable/Pipe [SK] to return to the   
					locate mode with the newly selected   
					marker type displayed.   
					− Adjust the Gain [3] again per step 4   
					above.   
					− Press Menu/OK [5].   
					C. Single Marker Locate   
					Step 1. Press Menu/OK [5:Toggle to LOCATE   
					MENU display]   
					Step 2. Press Marker [SK]   
					Step 3. Press Markr1 [SK Toggle] to select   
					desired utility.   
					Step 4. Markr2 should be OFF.   
					Gain level   
					Note: Only the marker types enabled in the setup   
					menu will be shown. (See 13.A Enabling/Disabling   
					Marker types). When scanning for markers, the   
					Gain Level [7] should be set high.   
					− When a marker is detected, adjust the   
					Gain [3] down until the Bar Graph [11]   
					([10] for 2550 locator) opens.   
					− The Bar Graph [11] ([10] for 2550   
					locator) will close, the audio will be   
					steady, and the Signal Strength [9] ([8]   
					for 2550 locator) will be maximum   
					when the receiver detects a marker of the   
					specified utility and has pinpointed its   
					location.   
					78-9000-0192-2 Rev C   
					43   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				D. Dual Marker Locate   
					Step 1. Press Menu/OK [5:Toggle to LOCATE   
					MENU display].   
					Step 2. Press Marker [SK].   
					Step 3. Press Markr1 [SK Toggle] to select desired   
					Utility.   
					Step 4. Press Markr2 [SK Toggle] to select desired   
					utility.   
					Note: Only the marker types enabled in the setup menu will be shown. See 13.A.   
					Enabling/Disabling Marker Types. When scanning for markers, the Gain Level [7]   
					should be set high.   
					− The third and fourth soft key commands will populate with the types of   
					utilities selected for Marker 1 and Marker 2.   
					Step 5. Adjust the Gain [3] downuntil the Bar Graphs [11] ([10] for 2550 locator) open.   
					− The Bar Graph [11] ([10] for 2550 locator) will close, the audio will   
					increase, and the Signal Strength [9] ([8] for 2550 locator) will increase   
					when the receiver detects a marker of the specified utility.   
					− When one of the two markers is detected, press the “XXX Only” [SK] for   
					the detected utility marker. (“XXX” represents the marker types selected. In   
					the above example, PWR Only and TEL Only.)   
					− The receiver will switch to Single Marker Locate in order to pinpoint the   
					marker (maximize the Signal Strength [9] ([8] for 2550 locator).   
					Step 6. Press Markr2 [SK Toggle] to return to Dual Marker Locate.   
					E. 3M™ iD Marker Depth   
					Step 1. Lower the tip of the receiver to the ground over the pinpointed marker.   
					Step 2. Press DEPTH [4].   
					− The receiver will examine the marker   
					(Calculating, please wait...)   
					− If the marker is a 3M™ iD Marker, the   
					receiver will display the depth of the   
					marker, and its identification (serial)   
					number.   
					44   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 3. To save the depth reading, press Mem   
					Select [SK].   
					− Five depth readings can be saved with   
					the time, date, and its identification   
					(serial) number.   
					− Save [SK] will place each entry in   
					sequential order in memory (M1 - M5)   
					until five readings have been stored.   
					The receiver will overwrite saved   
					entries in excess of five, beginning with   
					M1.   
					Step 4. Optional step: Press Clear All [SK] to delete all stored depth information.   
					Step 5. Press Mem Select [SK] to select a specific memory location (M1 - M5) to store   
					the depth readings. When the preferred location appears on the display, press   
					Save [SK]. The display and memory location will populate with the current   
					information.   
					Step 6. Each memory location can be reviewed by pressing Mem Select [SK].   
					Step 7. Press Menu/OK [5] to return to Marker Locate Mode.   
					F. Passive Electronic Marker (Non-iD) Depth   
					Step 1. Lower the tip of the receiver to the ground over the pinpointed marker.   
					Step 2. Press DEPTH [4].   
					− The receiver will examine the pinpointed marker.   
					− The display will instruct the operator to raise the unit 6 inches (15.2 cm)   
					from the ground.   
					Note: This 6-inch (15.2 cm) rise must be exact for the depth reading to be accurate.   
					A suggestion is to utilize a 6 inch (15.2 cm) piece of plastic pipe or wood as a spacer   
					between the ground and the tip of the receiver for this precise measurement.   
					Step 3. Raise the receiver 6 inches (15.2 cm). Press   
					the DEPTH [4] key again. The estimated   
					depth of the marker from ground level will   
					be displayed.   
					− Five depth readings can be saved with   
					the time and date.   
					78-9000-0192-2 Rev C   
					45   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 4. To access the memory locations, press Mem   
					Select [SK].   
					− Save [SK] will place each entry in   
					sequential order in memory (M1–M5)   
					until five readings have been stored. The   
					receiver will overwrite saved entries in   
					excess of five, beginning with M1.   
					Step 5. Optional step: Press Clear All [SK] to delete all stored depth information.   
					Step 6. Press Mem Select [SK] to select a specific memory location (M1 - M5) to store   
					the depth readings. When the preferred location appears on the display, press   
					Save [SK]. The display and memory location will populate with the current   
					information.   
					Step 7. Each memory location can be reviewed by pressing Mem Select [SK Toggle].   
					Step 8. Press Menu/OK [5] to return to Marker Locate Mode.   
					14. Creating/Editing Templates for   
					3M™ iD Markers   
					In the User Template display, the operator can create and modify templates to be   
					written to iD markers. Note that the easiest way to create user templates is by using   
					the 3M™ Dynatel™ PC Tool Kit Software on a PC and then downloading them to a   
					receiver via the RS232 Serial Port [16] ([15] for 2550 locator) on the receiver and the   
					provided RS232 cable or RS232-to-USB adapter cable. The 3M™ Dynatel™ PC Tool Kit   
					
					2550/2573/2250M/2273M/1420 Locator PC Tools xx.x.x (EXE xx.xMB).   
					A. Creating New Templates   
					Menu/OK [5:Toggle to MAIN MENU] + Data/Template [SK:2] + User Template [SK:c]   
					Step 1. Select Create New by pressing the up/down   
					arrows [SK].   
					Step 2. Press View/Edit [SK].   
					Step 3. Name the template.   
					Step 4. Press Modify [SK] to manually enter the   
					name of the template.   
					46   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 5. Select User/Edit.   
					Step 6. Press Menu/OK [5].   
					Step 7. Move the boxed cursor by pressing the left/   
					right arrows [SK], or up/down arrow [SK],   
					to move the cursor up or down.   
					Step 8. Press Select [SK] to enter the alphanumeric   
					character.   
					Step 9. Entry will appear at the top of the display.   
					Step 10. Press Menu/OK [5] when entry is complete.   
					Step 11. Press Menu/OK [5] to save or Exit [SK] to   
					cancel.   
					Note: To clear the previous field entry, select   
					the ‘back arrow’ with the cursor and delete the   
					previous entry.   
					Step 12. Navigate through the fields by pressing the   
					left/right arrows [SK].   
					Step 13. Press Modify [SK] to populate the   
					highlighted field.   
					Step 14. When modifying the Labels (left hand side   
					of template information) there are three   
					options for editing that are presented:   
					a. UserEdit   
					b. Choosing one of the common   
					(compressed) terms from the available   
					list of terms.   
					c. Del Row (delete row)   
					78-9000-0192-2 Rev C   
					47   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 15. When modifying the Descriptions (right   
					hand side of template information) there are   
					four options for editing that are presented:   
					a. UserEdit   
					b. Delete Row   
					c. Last 10 UserEdits   
					d. Show All - lists common compressed   
					terms   
					Step 16. Populate as many fields as possible from   
					the drop-down list of common (compressed)   
					terms available to conserve marker memory   
					space, or choose UserEdit if a term is not   
					found to meet the user's requirements. Select   
					term by pressing the up/down arrows [SK]   
					and press Menu/OK [5].   
					Step 17. Navigate to the next field by pressing the   
					left/right arrow [SK].   
					Step 18. Press Modify [SK] to populate the   
					highlighted field.   
					Step 19. Populate additional fields, as needed, using   
					the above procedure Steps 17 and 18.   
					Templates are limited to six Label and six   
					Description fields (256 bits of data total).   
					Step 20. When the template is complete, save the   
					template by pressing Menu/OK [5].   
					48   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				B. Editing Templates   
					The operator can select an existing template and   
					make changes to it in the same manner described in   
					14. A. Creating New Templates. The following save   
					screen will be displayed.   
					Over Write: Saves all modifications that have been made to the original template.   
					Rename: Overwrites the old template with the new name and all modifications. Display   
					will return to the template name field. Modify the name of the template and press   
					Menu/OK [5] to save.   
					Save New: Creates a new template containing all information. Original template remains   
					unchanged. Display will return to the template name field. Modify the name of the   
					template and press Menu/OK [5] to save.   
					Cancel: Clears all modifications made to any unsaved template.   
					Note: User templates can also be created on a PC using 3M™ Dynatel™ PC Tool Kit   
					Software and then downloaded to the receiver via the RS232 port [16] on the unit and   
					the provided RS232 cable or RS232-to-USB adapter cable.   
					78-9000-0192-2 Rev C   
					49   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				15. Writing 3M™ iD Markers   
					The Write Mode enables the user to write information into 3M™ iD markers. It is also   
					possible to edit the information to be written into an iD Marker.   
					Menu/OK [5:Toggle to MAIN MENU] + Write Mode [SK:1:1]   
					Step 1. Select a template from the list on the display   
					to be written into the marker by pressing   
					the up/down arrows [SK] to highlight the   
					preferred template. ‘Last Written /Read’ is   
					the most recent data that was written to/read   
					from a marker by the locator.   
					Step 2. Press View/Edit [SK].   
					− Four Write Mode options will be   
					displayed at the bottom of the screen.   
					[SK1] Overwrite: Will overwrite any data   
					existing on an unlocked marker if ‘Yes’ is   
					selected and ‘No’ will prevent overwrite.   
					− [SK2] X-Type: Choose ‘Yes’ if writing to   
					a Gen 2 marker and ‘No’ if writing to a   
					Gen 1 marker. Gen 2 markers will have   
					an “X” following the serial number that is   
					printed on the attached tag.   
					− [SK3] Marker: Select type of marker to   
					be written by repeatedly pressing Marker   
					[SK Toggle].   
					− [SK4] Lock/Unlocked: Press [SK4] to   
					toggle between locking and unlocking   
					the marker. The default setting is   
					unlocked and note that a locked unit   
					cannot be modified once locked. If the   
					marker will be locked then a verification   
					screen will appear to ensure that the   
					marker is locked intentionally.   
					Step 3. Press Menu/OK   
					− The selected template will be displayed.   
					The arrow on the right side of the display   
					indicates there is more information than   
					can be displayed on the screen (scroll   
					down by pressing the down arrow [SK]).   
					Step 4. Enter user information that will be written   
					to this marker. (See 15.A Modifying Marker   
					Data to be Written)   
					50   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 5. Verify that all information is correct   
					Step 6. Hold the locator directly over the top of the   
					marker. The locator should be within the   
					following maximum writing ranges for each   
					of the different 3M™ iD Marker formats;   
					− Near Surface iD Marker = 6 in (15 cm)   
					maximum   
					− Ball iD Marker = 12 in (30 cm)   
					maximum   
					− Full Range iD Marker = 24 in (61 cm)   
					maximum   
					Step 7. Press Start Write [SK].   
					78-9000-0192-2 Rev C   
					51   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 8. After writing to the 3M™ iD Marker is   
					completed, the following screen will be   
					displayed. The following messages may   
					appear in the writing process.   
					− Message 1. If the overwrite option was   
					set to "No" And there was data present   
					on the target market then the following   
					screen will be displayed;   
					− Message 2. When writing to a passive   
					marker or the wrong frequency then the   
					following will be displayed.   
					− Message 3. This screen indicates that   
					X-Type marker option was incorrectly set   
					to "Yes" or "No". Verify the serial number   
					that is displayed on the marker ends with   
					an “X” to select "Yes" for X-Type, else   
					select "No".   
					Note: Once the marker data has been locked, the information contained on the marker   
					is PERMANENT. Choosing to permanently lock the marker data is irreversible. Once   
					the data is locked it can not be overwritten. Assure that the data that is being written is   
					correct before proceeding.   
					A. Modifying Marker Data to be Written   
					To alter the information to be written into the marker   
					Press Menu/OK [5:Toggle to MAIN MENU] + Write Mode [SK:1].   
					Step 1. Select a template from the list on the display   
					to be written into the marker by pressing   
					the up/down arrows [SK] to highlight the   
					preferred template. ‘Last Written/Read’ is   
					the most recent data that was written to/read   
					from a marker by the receiver.   
					52   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 2. Press View/Edit [SK].   
					Four Write Mode options will be displayed   
					at the bottom of the screen.   
					− [SK1] Overwrite: Will overwrite any   
					data existing on an unlocked marker if   
					‘Yes’ is selected and ‘No’ will prevent   
					overwrite.   
					− [SK2] X-Type: Choose ‘Yes’ if writing to   
					a Gen 2 marker and ‘No’ if writing to a   
					Gen 1 marker. Gen 2 markers will have   
					an “X” following the serial number that   
					is printed on the attached tag.   
					− [SK3] Marker: Select type of marker to   
					be written by repeatedly pressing Marker   
					[SK Toggle].   
					− [SK4] Lock/Unlocked: Press [SK4] to   
					toggle between locking and unlocking   
					the marker. The default setting is   
					unlocked and note that a locked unit   
					cannot be modified once locked. If the   
					marker will be locked then a verification   
					screen will appear to ensure that the   
					marker is locked intentionally.   
					Step 3. Press Menu/OK   
					The selected template will be displayed.   
					The arrow on the right side of the display   
					indicates there is more information than can   
					be displayed on the screen (scroll down by   
					pressing the down arrow [SK]).   
					Step 4. Press the up/down arrows [SK] to highlight   
					the information to change.   
					78-9000-0192-2 Rev C   
					53   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 5. Press Modify [SK]. The percentage   
					displayed in the upper right portion of the   
					display indicates the remaining memory   
					available on the marker.   
					Step 6. The operator may select User Edit in order   
					to ‘type’ the modification, or Delete Row to   
					remove the entire row from the template, or   
					select Show All to display a list of common   
					compressed terms.   
					Note: Using a common compressed term requires   
					less memory in the marker.   
					Step 7. Select an option from the list by pressing the   
					up/down arrows [SK]. Press Menu/OK [5].   
					Step 8. If User Edit is selected, the following   
					display will appear;   
					Step 9. Move the boxed cursor to the ‘back arrow’   
					and press Select [SK] to delete the entry to   
					be modified.   
					Step 10. Move the boxed cursor by pressing the left/   
					right arrows [SK], or the Up/ Down Arrow   
					[SK], to move the cursor to the next row.   
					Step 11. Press Select [SK] to enter the alphanumeric   
					character.   
					− Entry will appear at the top of the display.   
					Step 12. Press Menu/OK [5] when entry is complete.   
					Step 13. If Show All is selected, the following display   
					will appear.   
					Step 14. Select a common compressed term from the   
					list by pressing the up/down arrows [SK].   
					Step 15. Press Menu/OK [5]. The modification will   
					automatically populate the marker template.   
					54   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				16. Reading 3M™ iD Markers   
					The operator can retrieve the data from the iD marker by pressing Read [SK] on the   
					Marker Locate display.   
					The receiver tip should be lowered to the ground to reach maximum read depth.   
					If more than one 3M™ iD Marker of the same utility is detected, the receiver will read   
					the first marker and display the data from the marker.   
					The fourth yellow command key will be labeled   
					“Read Next”. Press this key to extract the data from   
					the other marker.   
					All the information retrieved from the marker, including the date and time read, is   
					saved into the ‘Read History’ file of the receiver. If a hand-held GPS device is used in   
					conjunction with the receiver, coordinates will be saved into the "Read History" file also.   
					(See 17. Reviewing Marker Read/Write History.)   
					17. Reviewing Marker Read/Write History   
					A. Read History   
					The Read History mode is a historical file of all information that has been read from   
					targeted markers (100 memory locations).   
					Menu/OK [5:Toggle to MAIN MENU] + Data/Template [SK:2] + Read History [SK:a]   
					The Read History screen displays the date and   
					time that each marker was read, and its unique   
					identification (serial) number.   
					• Select the marker data to be viewed by pressing   
					the up/down arrows [SK]   
					• Press Marker Details [SK] to view all data that   
					was retrieved from the marker.   
					• Press Read History [SK] to return to list or press   
					Exit [SK] to return to Data/Template review   
					display.   
					78-9000-0192-2 Rev C   
					55   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				B. Write History [SK]   
					Menu/OK [5:Toggle to MAIN MENU] + Data Template [SK:2] + Write History [SK:b]   
					• Select the marker data to be viewed by pressing   
					the up/down arrows [SK].   
					• Press Write Details [SK] to view all data that was   
					sent to the marker.   
					• Press Write History [SK] to return to the list of   
					written data.   
					• Press Exit [SK] to return to Data/Template review   
					display.   
					For additional information concerning writing to 3M™ iD Markers, refer to   
					
					18. GPS Compatibility Operation   
					A. Capturing the GPS Coordinates (Capture Mode / Mode 1)   
					Menu/OK [5:Toggle to MAIN MENU] +   
					[SK:3] + NMEA   
					If the GPS device is not configured properly, there is an error communicating with the   
					receiver, or the GPS device has not acquired enough satellites to pinpoint the location,   
					the receiver will display the message “Insert External Device”.   
					When the receiver is communicating with a GPS   
					device, the LAT and LONG coordinates received   
					from the device will appear on the marker locate   
					display.   
					Step 1. Locate a marker (See 13.C. Single Marker Locate)   
					Step 2. Press Read [SK]   
					The information from the 3M™ iD marker, as well as the GPS coordinates, will display   
					on the receiver display. This information is saved automatically in the Read Marker   
					History. (See 17. Reviewing Marker Read/Write History.)   
					If the marker is a passive marker (rather than iD) the receiver will display “No iD   
					Marker Found”. The GPS coordinates of the attempt to read the non-iD marker are   
					stored in the Read Marker History as serial number # 0000-0000-0000. The marker   
					details will indicate “not an iD marker”, but will display the GPS coordinates.   
					56   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				B. Sending 3M™ iD Marker Data to GPS   
					(Capture-Transmit Mode / Mode 2)   
					Menu/OK [5:Toggle to MAIN MENU] +   
					[SK:3] + GIS   
					Receivers that have marker locating capability (indicated by ‘iD’ in the model number)   
					can be configured to send 3M™ iD Marker data directly to some GPS devices. When   
					an iD marker is located and read, the information read from the iD marker with feature   
					and attribute data is sent to the GPS device and is stamped with latitude, longitude and   
					date/time data. The data acquired during this logging process can be uploaded to GIS   
					mapping software. For more information and detailed instructions pertaining to specific   
					
					C. Path Mapping with GPS   
					The 3M Dynatel™ Cable and Pipe Locators 2500 Series are compatible with hand-   
					held GPS devices and now have the ability to map the path of underground target   
					facilities. While measuring the depth to the target, the technician can automatically log   
					the coordinates of the path to the GPS device. These logged points contain the Trace   
					template that can have valuable information regarding the facility (owner, utility, size,   
					etc.) and the method used to find the path (frequency, current, and measured depth).   
					In order to transmit the path information to a GPS device, the GPS device has to have   
					the ability to accept information on one of its com ports at 4800 Baud. Using the manual   
					supplied with the GPS device, configure the com port of the GPS device to communicate   
					with the receiver.   
					If ArcPad™ softwae is the mapping software on the mobile device, download the 3M   
					software application script from the website: www.3M.com/dynatel.   
					With ArcPad™ application installed, the receiver will send the path information (locate   
					frequency, depth, current, and trace template information) into the software program as a   
					logged point and can be saved as a .shp file.   
					78-9000-0192-2 Rev C   
					57   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				1. Creating Trace Templates   
					The easiest way to create a Trace template is using the 3M™ Dynatel™ PC   
					
					2550/2573/2250M/2273M/1420 Locator PC Tools xx.x.x (EXE xx.xMB).   
					• Create a TRACE template.   
					• Save and download the template to the receiver.   
					Up to four Trace Templates can be stored on the Receiver.   
					Each Trace template is limited to 132 user editable characters.   
					The trace template appears in table format: two columns with six lines.   
					The first column is limited to 8 characters and the second column is limited to 14   
					characters. In addition to the 132 character table, the receiver will send a sequence number,   
					the frequency, the measured depth of the conductor, and the current to the GPS device.   
					2. Select Com Port Setting   
					Menu/OK [5:Toggle to MAIN MENU] +   
					[SK:3] + GIS [SK] (or PDA [SK])   
					If the GPS device has the ability to send NMEA coordinates on its com port and has the   
					ability to receive information at 4800 baud, set the receiver’s com port to GIS.   
					If the GPS device only has the ability to receive information, set the com port of the   
					receiver to PDA mode.   
					Log Prompt = On: Before the receiver returns to locate mode, a verification display   
					will pop up on the receiver with the trace template information that will be sent to the   
					GPS device. This information can be modified and confirmed. Press Menu/OK [5] to   
					send to GPS device.   
					Log Prompt = Off: When the receiver returns to locate mode, the trace template and   
					locate information will be sent automatically to the GPS device.   
					3. Sending Path Information to GPS Device   
					Step 1. Establish communication with the GPS device.   
					Step 2. Set COM port on receiver.   
					Step 3. Locate target utility.   
					Step 4. Measure depth to target utility.   
					− If Log prompt is activated, when the TRACE button is pressed (or after a   
					five second delay), a display will appear that displays the path information.   
					Step 5. Press Menu/OK [5] to send the information to the GPS device, or Exit to   
					prevent the exchange.   
					For more information refer to the software release notes at www.3M.com/dynatel.   
					58   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				19. Additional Applications   
					A. Aerial Faults (Toning) (3M™ Dynatel™ Models 2573 and 2573-iD only)   
					Transmitter Setup   
					Step 1. Connect the transmitter (based on type of fault) as described in Connection   
					Diagrams in the following section.   
					Step 2. Press and hold off [T-1] to perform a battery test.   
					Step 3. Press on: Ohm-meter/Faul Locate/Tone [T-2] to power the Transmitter on and   
					to verify the fault.   
					Step 4. Press on: Ohm-meter/Faul Locate/Tone [T-2] twice more to select the Tone   
					mode.   
					Step 5. The Digital Display [T-4] will alternately flash between 577 and 200K.   
					Step 6. Press Output Level [T-5] for high or maximum output level.   
					Receiver Setup   
					Step 1. Press On/Off [1] to turn the receiver on.   
					Step 2. Press Menu/OK [5:Toggle to MAIN MENU]   
					Step 3. Press Tone/Ext [SK] to select Tone mode.   
					Step 4. Press Freq [SK Toggle] to select 577Hz.   
					Step 5. Connect a toning coil to the receiver External Jack [15] ([14] for 2550 locator).   
					Step 6. Move the toning coil along the cable and find a peak signal then press Gain [3]   
					down to adjust the receiver gain.   
					Step 7. Press Speaker Volume Control [13] ([12] for 2550 locator) to adjust the speaker   
					volume as needed.   
					Step 8. Follow the cable with the toning coil.   
					− When the receiver detects a short, cross, or ground fault (Connection   
					Diagram Figures #1, #2, or #3), the audio and Signal Strength [9] ([8] for   
					2550 locator) will stop or drop off sharply.   
					− When the receiver detects a split (Connection Diagram Figure #4) the audio   
					and Signal Strength [9] ([8] for 2550 locator) will increase significantly.   
					− When verifying a split (Connection Diagram Figure #5) the audio and   
					Signal Strength [9] ([8] for 2550 locator) will decrease after the toning coil   
					has passed the split.   
					78-9000-0192-2 Rev C   
					59   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Connection Diagrams   
					Short:   
					Figure #1: Red clip to Tip; Black clip to ring.   
					Cross:   
					Figure #2: Red clip to the crossed conductor of   
					one pair; Black clip to the crossed conductor of   
					the other pair.   
					Ground:   
					Figure #3: Red clip to the faulted conductor;   
					Black clip to ground.   
					Split:   
					Figure #4: Red clip to Tip of Pair 1; Black clip   
					to Ring of Pair 1.   
					Verify Split:   
					Figure #5: Red clip to good conductor of Pair   
					1; Black clip to split conductor of Pair 2   
					B. Cable Identification   
					1. Transmitter Setup   
					Step 1. Connect the 3M™ Dyna-Coupler to the Transmitter Output Jack [T-6] using the   
					coupler cable.   
					Note: Cable Identification requires two Dyna-Couplers: one at the Transmitter and   
					one at the Receiver.   
					Step 2. Clamp the Dyna-Coupler around the cable or both the tip and ring of a pair.   
					Make sure the jaws fully close.   
					Step 3. Press and hold off [T-1] to perform a battery check.   
					Step 4. Press on: Ohm-meter/Fault Locate/Tone [T-2] three times to set the transmitter   
					to Tone mode.   
					Step 5. The Indicator Flag will light in the Digital Display [T-4] under the Tone icon.   
					60   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Step 6. Press Output Level [T-5] for high or maximum output level.   
					Step 7. The Indicator Flag will light in the Digital Display [T-4] above the Output   
					Level icon when in high output power level and flash when in maximum output   
					power level.   
					Step 8. The Digital Display [T-4] will alternately flash between 577 and 200K.   
					2. Receiver Setup   
					Step 1. Press On/Off [1] to power the receiver on.   
					Step 2. Press Menu/OK [5].   
					Step 3. Press Tone/Ext [SK] to select Tone mode.   
					Step 4. Connect a second coupler to the Receiver’s External Jack [15] ([14] for   
					2550) using the Earth Contact Frame cable (4 ft. (1.2m) cable) or another   
					coupler cable.   
					Step 5. Press Freq [SK Toggle] to select the highest transmitter frequency (200K).   
					Step 6. Check the first cable in the group by clamping the coupler around the cable.   
					Step 7. Press Gain [3] down and observe the numerical Signal Strength [9] ([8] for   
					2550).   
					Step 8. Remember the Signal Strength [9] ([8] for 2550 locator) value and continue by   
					clamping the coupler around the next cable in the group.   
					− If the Signal Strength [9] ([8] for 2550 locator) is greater than the previous   
					observation, press Gain [3] down.   
					− If the Signal Strength [9] ([8] for 2550 locator) is less than before, ignore it.   
					− After checking all the cables in the group, the cable with the highest Signal   
					Strength [9] ([8] for 2550 locator) reading is the target cable.   
					20. Help Mode   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] +   
					[SK:7]   
					The help display contains basic information about the unit and its operation. It is   
					designed to be a quick reference guide.   
					• Press the double up/down arrows [SK] to navigate between sections.   
					− The single up/down arrows [SK] will scroll the display line by line.   
					78-9000-0192-2 Rev C   
					61   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				21. 3M™ Dynatel™ PC Tool Kit and Locator   
					Software Upgrades   
					Locator software upgrades are periodically released and can be downloaded, free of   
					
					software link is titled Dynatel™ M-Series Locator PC Tools. To download the software,   
					click on the link and then select 3M™ Dynatel™ M-Series Underground Locator PC   
					Tools. Selecting this link will display the latest software downloads as well as any   
					Release Notes related to the current software release.   
					Once downloaded to your PC, double click the file and an auto-installer will install the C   
					Tool desktop software. Double click the Dynatel PC Tool Kit icon on the desktop. Using   
					the provided RS232 cable, or RS232-to-USB adapter cable, connect the Serial Port [14]   
					on the locator to the PC and power the locator on. Click the Upgrade Software button in   
					PC Tools to begin upgrade. Do not disconnect or power off the locator while the upgrade   
					is in progress. Wait until the software indicates that the installation was successful. This   
					will take approximately 6 to 7 minutes to complete.   
					The Dynaltel PC Tool Kit provides the user an excellent interface between the receiver   
					and a PC. This software utility provides the tools by which the user can:   
					• Upgrade the receiver to the latest software revision   
					• Program one or multiple receivers to best suit specific user configurations   
					• Load an alternate language into the receiver   
					• Utilize the 3M™ iD Marker utility to:   
					− Create templates for writing data to iD markers, or create Trace Templates for GPS   
					path tracing when connected to a GPS device.   
					− Download iD marker data that has been written or read by the receiver for   
					documentation databases.   
					Embedded in the desktop software is the most current software for the receiver, which   
					affords the user the option of upgrading the unit without returning the unit to the   
					3M Service and Repair Center.   
					Please refer to the operating instructions included with the software.   
					22. Self Test of Receiver   
					Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] + S/N# [SK:6]   
					This operation performs a self-test on the receiver.   
					The receiver will display current information about the unit (model number, serial   
					number, software revision, and hardware revision).   
					• Press Run [SK] to start the self test.   
					− A status bar will appear while the self test is running.   
					− Results will appear on the display when the test is complete.   
					− Press Exit [SK] to return to MAIN MENU.   
					62   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				23. Product Description And Optional Accessories   
					A. Product Description   
					2550   
					2573   
					12-watt transmitter   
					Direct Connect Cable Clip Size: For U.S. models only: C= Communication Clip only;   
					U=Utility Clip only; For Export models only: U for 2550E or CU for 2573E=Communication and Utility Clips   
					iD=Locates electronic markers, including read/write iD Marker capability.   
					E = Export version; no designation = U.S. version   
					2550 Pipe/Cable Locator; 2573 Cable/Pipe/Fault Locator   
					Example: 2573-ID/U12   
					Description: 3M Dynatel™ Cable/Pipe/Fault Locator 2573 with marker locating   
					capability (including reading and writing to 3M iD Markers); U.S. version; Utility direct   
					connect cables (clips), 12-Watt Transmitter (see Section 23B for the additional items   
					included with this part number).   
					Several standard configurations are available. Please see the following chart, then   
					contact your 3M Distributor or 3M Representative for assistance in product selection.   
					3M Customer Service can be reached at 1-800-426-8688.   
					NOTE: The “/” in the Product Description is replaced by a “-” for the non-iD version   
					locators.   
					B. Standard Configurations   
					US Version Locators   
					2550-U12   
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					2550-ID/U12   
					Export Version Locators   
					2550E-U12   
					2550E-ID/U12   
					US Version Fault Finders   
					2573-C12   
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					2573-U12   
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					2573-ID/C12   
					2573-ID/U12   
					Export Version Fault Finders   
					2573E-CU12   
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					x 
					2573E-ID/CU12   
					x 
					78-9000-0192-2 Rev C   
					63   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				C. Optional 3M™ Accessories for 3M Dynatel™ Locators   
					Item   
					Part Number   
					Direct Connect Cables, Small Clip, 1/4" (6.4mm),   
					Communications version, 10' (3 m) cable length   
					2892   
					Direct Connect Cables, Large Clip, 5/8" (15.8 mm), Utility   
					version, 10’ (3 m) cable length   
					2876   
					9012   
					Direct Connect Cables, Small Clip, 1/4" (6.4 mm),   
					Communications version, 5’ (1.5 m) cable length   
					Ground Extension Cable   
					9043   
					3001   
					4001   
					1196   
					3019   
					Dyna-Coupler Clamp 3" (75 mm)   
					Dyna-Coupler Clamp 4.5" (114 mm)   
					Dyna-Coupler Clamp 6" (150 mm) w/ pouch   
					Locator Coupler Accessory Kit, 3" (75 mm)   
					(Includes 3" (75 mm) Dyna-Coupler, Coupler Cable and Coupler Pouch)   
					Locator Coupler Accessory Kit, 4.5" (114 mm)   
					4519   
					(Includes 4.5" (114 mm) Dyna-Coupler, Coupler Cable and Coupler   
					Pouch)   
					Locator Coupler Accessory Kit, 6" (150 mm)   
					1196/C   
					(Includes 6" (150 mm) Dyna-Coupler, Coupler Cable and Coupler Pouch)   
					Coupler Cable 12' (3.6 m)   
					9011   
					Rechargeable Battery (12-volt DC)   
					Cigarette Lighter Adapter Cable (12-volt DC)   
					Carrying Bag   
					2200RB   
					457-594-000   
					2500   
					33 kHz Sonde (ADP; Active Duct Probe)   
					Earth Contact Frame (A-Fame)   
					Earth Contact Frame (A-Fame) Cable   
					Ground Rod, Stainless Steel   
					3229   
					3014   
					9026   
					8006   
					64   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				24. Receiver Specifications   
					Item   
					Specification   
					Modes   
					Trace View   
					Directional Peak   
					Directional Null   
					Special Peak   
					Induction Peak   
					Frequency Response:   
					Active   
					577 Hz   
					1 kHz   
					8 kHz   
					33 kHz   
					82 kHz   
					200 kHz   
					Passive   
					Power   
					31.5 kHz (CATV)   
					15 – 30 kHz (LF)   
					50 Hz, 5th and 9th harmonic of 50 Hz   
					60 Hz, 5th and 9th harmonic of 60 Hz   
					(100 / 120 Hz) rectified power   
					Auxiliary   
					333 Hz   
					512 Hz   
					560 Hz   
					User Defined Frequencies   
					Display   
					Four   
					LCD   
					Gain Control   
					Manual and Automatic   
					4–5 lbs. (1.8–2.3 kg) (model dependent)   
					8 AA (LR6)   
					Weight w/batteries   
					Battery Qty. and size   
					Battery Life   
					30 hours average   
					Depth Accuracy   
					±2% ± 2 in. (5 cm) for 0–60 in. (0-1.5 m)   
					±6% ± 2 in. (5 cm) for 60–120 in. (1.5–3.0 m)   
					±10% ± 2 in. (5 cm) for 120–180 in. (3.0 m–4.5 m)   
					Depth Range   
					0–360 in. (0–914 cm)   
					± 15% ± 2 in. (5 cm)   
					Marker depth accuracy   
					Maximum Program Range   
					3M iD Markers   
					Near-Surface   
					Ball Marker   
					Full-Range   
					6 in (15 cm)   
					12 in (30 cm)   
					24 in (61 cm)   
					78-9000-0192-2 Rev C   
					65   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Item   
					Specification   
					Read Range 3M™ iD Markers   
					Near-Surface   
					Ball Marker   
					Full-Range   
					3 ft (0.9 m)   
					5 ft (1.5 m)   
					8 ft (2.4 m)   
					Detection Depth 3M Non-iD (Passive)   
					Markers   
					Near Surface   
					Ball Marker   
					Mid-Range   
					Full-Range   
					2 ft (0.6 m)   
					5 ft (1.5 m)   
					6 ft (1.8 m)   
					8 ft (2.4 m)   
					66   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				25. 12-Watt Transmitter Specifications   
					Item   
					Specification   
					Trace Mode   
					577 Hz   
					1 kHz   
					8 kHz   
					33 kHz   
					82 kHz   
					200 kHz   
					Fault Mode   
					10/20 Hz -Fault signal   
					(2573 models only)   
					577 Hz / 33 kHz -Trace signal   
					Note: The fault locating limit is 2.0MΩ, although the transmitter's ohm-   
					meter mode can display a fault resistance up to 10MΩ.   
					Tone Mode   
					577 Hz and 200 kHz pulsing at 8 Hz   
					(2573 models only)   
					Induction Mode   
					8 kHz   
					33 kHz   
					82 kHz   
					200 kHz   
					Output Power   
					Normal setting: 0.5 W   
					High setting: 3 W @ 577 Hz, 1 kHz, 8 kHz, 33 kHz; 1 W @ 82 kHz, 200 kHz   
					Maximum setting: 12 W @ 577 Hz, 1 kHz, 8 kHz; 10 W @ 33 kHz; 1 W @ 82   
					kHz, 200 kHz (with external DC power source)   
					(in Direct Connect mode)   
					Output Voltage (Maximum)   
					Output Protection   
					70 Vrms   
					240 Vrms   
					Weight w/batteries   
					w/ alkaline batteries only: 5.2 lbs (2.4 kg)   
					w/ rechargeable battery (2200RB) and alkaline batteries: 9.2 lbs (4.2 kg)   
					Battery Qty. and size   
					Typical Battery Life   
					For Normal and High Output Power: 6 "C" size, Alkaline (LR14)   
					For Maximum Output Power: Rechargeable Battery (2200RB), 12V-6AH,   
					Sealed Maintenance-Free Lead (Pb)-Acid Battery   
					(See safety information below.)   
					Normal Output Power level: 50 hours   
					High Output Power level: 10 hours   
					Typical transmitter specified battery life (listed above) is increased by 40%   
					when using the 2200RB Rechargeable Battery (12 volt). Using the 2200RB   
					bypasses the alkaline batteries.   
					Maximum Output Power level: 4 hours (Maximum Output Power level   
					achieved using 2200RB Rechargeable Battery.)   
					External DC Power   
					9–18 V DC   
					Rechargeable Battery Fuse   
					5 Amp / 32 Volt   
					Littelfuse MINI® Blade # 0297005   
					Cigarette Lighter Adapter   
					4 Amp/Fast Blow 250V   
					Cable Fuse   
					78-9000-0192-2 Rev C   
					67   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				26. Environmental and Regulatory Specifications   
					Item   
					Specification   
					Standard   
					IP54   
					Regulatory   
					FCC compliant, FCC Part 15   
					-4°F to 122°F (-20°C to 50°C)   
					-4°F to 158° F (-20°C to 70°C)   
					Operating Temperature   
					Storage Temperature   
					27. Rechargeable Battery Information   
					UN2800 classification as “Batteries, wet, Non-Spillable, and electric storage”   
					as a result of passing the Vibration and Pressure Differential Test described in   
					DOT [49 CFR 173.159(d) and IATA/ICAO [Special Provision A67].   
					! CAUTION   
					To reduce the risks associated with environmental contamination and possible injury:   
					The 12W transmitter utilizes the 2200RB rechargeable battery for the Maximum Output Power   
					level. This is a maintenance-free sealed lead (Pb)-acid battery.   
					• 
					• 
					• 
					• 
					• 
					• 
					• 
					• 
					• 
					Replace the battery if the acid solution leaks.   
					The batteries are not serviceable.   
					Do not disassemble batteries.   
					Do not remove vent caps.   
					Do not rest tools or cables on batteries.   
					Store lead-acid batteries with adequate ventilation.   
					Do not heat batteries above 140°F (60°C)   
					Never recharge batteries in an unventilated, enclosed space.   
					Spent batteries must be treated as hazardous waste. Dispose of batteries and electronic   
					components in accordance with all regulations.   
					• 
					• 
					Do not incinerate batteries.   
					Always remove/disconnect batteries when not in use or storing for long periods of time.   
					68   
					78-9000-0192-2 Rev C   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				78-9000-0192-2 Rev C   
					69   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				This is the EU symbol for equipment that is covered under the Waste   
					from Electrical and Electronic Equipment (WEEE) directive per CENELEC   
					Specification 5041. It indicates that certain products should not be   
					discarded in the trash, but rather should be recycled. This applies to all   
					electronic pluggable and battery powered products.   
					3M and Dynatel are trademarks of 3M Company.   
					ArcPad is trademark of Environmental Systems Research Institute, Inc. (ERSI).   
					MINI and Littlefuse are trademarks of Littlefuse, Inc.   
					Important Notice   
					All statements, technical information and recommendations related to 3M Products are based on information believed to be   
					reliable, but the accuracy or completeness is not guaranteed. Before using the 3M Product, you must evaluate it and determine   
					if it is suitable for your intended application. Because conditions of Product use are outside of our control and vary widely you   
					assume all risks and liability associated with such use. Any Product-related statements not contained in current 3M publications,   
					or any contrary statements contained in your purchase order, shall have no force or effect unless expressly agreed to in writing by   
					an authorized officer of 3M.   
					Limited Product Warranty   
					3M Locators (except accessories), will conform to 3M's published specifications and will be free from defects in material and   
					manufacture for a period of twelve (12) months from the date of purchase. Dry cell batteries included in any of 3M's products are   
					warranted only to the extent the battery manufacturer determines such batteries are covered by its warranty. Locating accessories   
					are warranted for ninety (90) days after purchase. 3M's obligations and liability under this warranty are limited to repairing,   
					replacing or refund of the purchase price, at 3M's option, any of 3M's products which, after normal and proper usage, are   
					determined by 3M to be defective. This warranty does not extend to any of 3M's products which have been subjected to misuse,   
					neglect, accident or improper applications, nor shall it extend to products which have been repaired or substantially altered   
					outside 3M's manufacturing or repair facility, nor to any associated instruments, equipment or apparatus. Before utilizing any   
					of 3M's products, BUYER should determine the suitability of the product for BUYER'S intended use. 3M MAKES NO OTHER   
					WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY   
					OR FITNESS FOR A PARTICULAR PURPOSE. In no case shall 3M be liable for any special, incidental, or consequential   
					damages based upon breach of warranty, breach of contract, negligence, strict liability or any other legal theory. This limitation   
					does not apply to claims for personal injury. Special Condition: Shipments into authorized distributor/supplier locations will have   
					an additional ninety (90) day warranty period.   
					3 
					Electrical Markets Division   
					6801 River Place Blvd.   
					Austin, TX 78726-9000   
					1-800-200-0265   
					FAX: 1-877-601-1305   
					
					Please Recycle. Printed in USA.   
					© 3M 2014. All Rights Reserved.   
					78-9000-0192-2 Rev C   