| I N S T A L L A T I O N / O P E R A T I O N   PMM9A, PMM12A,   PMM15A, PMM20A   Monochrome Monitors   ® C2902M (10/02)   LIST OF ILLUSTRATIONS   Figure   Page   1 2 3 4 5 Singe-Monitor Installation (PMM15A Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Multiple-Monitor Installation (PMM15A Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7   Location of Controls (PMM15A Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Vertical Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Horizontal Tear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   LIST OF TABLES   Table   Page   Video Coaxial Cable Wiring Distances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7   A C2902M (10/02)   3 IMPORTANT SAFEGUARDS AND WARNINGS   Before installing your equipment, please read the following important safeguards as outlined by Underwriters Laboratories Inc.   Read Instructions   All the safety and operating instructions should be read before the appliance is operated.   Retain Instructions   The safety and operating instructions should be retained for future reference.   Heed Warnings   All warnings on the appliance and in the operating instructions should be followed.   Follow Instructions   All operating and use instructions should be followed.   Cleaning   Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.   Attachments   Do not use attachments not recommended by Pelco as they may cause hazards.   Water and Moisture   Do not use this CCTV product near water–for example, near a kitchen sink, wash bowl, bath tub, sprinkler, in a wet basement or   near a swimming pool, and the like unless it is specifically marked “for use in wet locations.”   Accessories   Do not place this CCTV product on an unstable cart, stand, tripod, bracket, or table. The CCTV product may fall, causing serious   injury to a child or adult and serious damage to the appliance. Use only with a cart, stand, tripod, bracket or table recom-   mended by Pelco or supplied by Pelco with the product. When mounting the appliance, follow Pelco’s installation instructions,   and use only mounting accessories recommended by Pelco.   Cart & Stand   An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause   the appliance and cart combination to overturn.   Ventilation   Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the CCTV product and to   protect it from overheating. These openings must not be blocked or covered. The openings should never be blocked by placing   the CCTV product on furniture, carpet, or similar surfaces. The CCTV product should never be placed near or over radiators or   heat registers. This CCTV product should not be placed in a built-in installation, such as a book case or rack, unless proper   ventilation is provided or Pelco’s installation instructions are adhered to.   Power Sources   This CCTV product should only be operated from the type of power source indicated on the marketing label. If you are not sure   of the type of power supply to your installation location, consult your local electrical building official or power company. Refer   to the operating instructions for appliances intended to operate from battery or other power sources.   Grounding   This CCTV product is equipped with a grounding-type plug. This plug will only fit into a grounding-type power outlet. This is a   safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do   not defeat the grounding-type plug since it is provided to ensure your safety.   Power-Cord Protection   Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against   them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.   Overloading   Do no overload wall outlets and extension cords as this can result in a risk of fire or electric shock.   4 C2902M (10/02)   Object and Liquid Entry   Never push objects of any kind into this CCTV product through openings as they may touch dangerous voltage points or short-   out parts that could result in a fire or electric shock. Never spill liquid of any kind on the CCTV product.   Servicing   Do not attempt to service this CCTV product yourself as opening or removing covers may expose you to dangerous voltages or   other hazards. Refer all servicing to qualified service personnel.   Damage Requiring Servicing   Unplug this CCTV product from the wall outlet and refer servicing to qualified service personnel under the following conditions:   a. When the power-supply cord or plug is damaged.   b. If liquid has been spilled or objects have fallen into the CCTV product.   c. If the CCTV product is not marked “Suitable for Wet Locations” and it has been exposed to rain or water.   d. If the CCTV product does not operate normally by following the operating instructions. Adjust only those controls that are   covered by the operating instructions as an improper adjustment of other controls may result in damage and often will   require extensive work by a qualified technician to restore the CCTV product to its normal operation.   e. If the CCTV product has been dropped or the cabinet has been damaged.   f. When the CCTV product exhibits a distinct change in performance–this indicates a need for service.   Replacement Parts   When replacement parts are required, be sure the service technician has used replacement parts specified by Pelco or have the   same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards.   Safety Checks   Upon completion of any service or repairs to this CCTV product, ask the service technician to perform safety checks to   determine that the CCTV product is in proper operating condition.   WARNING   This product has been evaluated for INDOOR USE ONLY unless it bears the marking FOR USE IN WET LOCATIONS.   WARNING   To reduce the risk of electric shock hazard, do not remove the cover of the unit. This unit can not be serviced by the user and   must be sent to a qualified service person for repair when it fails to function.   The lightning flash with an arrow head symbol within an equilateral triangle means that if the enclosure is   opened, electrical circuitry is exposed which imposes an electric shock hazard to persons present.   The exclamation point within an equilateral triangle means the operating instructions contain important   information on how to operate and maintain the appliance.   C2902M (10/02)   5 DESCRIPTION   The PMM9A, PMM12A, PMM15A, and PMM20A are high resolution, black and white, CCTV video monitors. The cabinets are   made of steel for ruggedness and, with the exception of the picture tube, the circuitry is all solid-state for reliability.   MODELS   PMM9A   Black and white monitor, 9-inch (22.86 cm) picture display, 96-256 VAC, 50/60 Hz, EIA/CCIR, auto-sensing   Same as PMM9A except 12-inch (30.48 cm) picture display   Same as PMM9A except 15-inch (38.10 cm) picture display   PMM12A   PMM15A   PMM20A   Same as PMM9A except 20-inch (50.80 cm) picture display   INSTALLATION   The following parts are supplied:   Monitor   Two power cords (1 USA standard and 1 European standard)   MOUNTING   The monitor has rubber feet and may be placed on any horizontal surface, such as a desk or table. The monitor also can be   mounted to a wall or ceiling with an appropriate mount. If you have a PMM9A, PMM12A, or PMM15A monitor, it can be   installed in a 19-inch equipment rack with a suitable rack-mounting kit. For mounting to a wall or ceiling or in a rack, refer to   the instructions with the mount.   CONNECTIONS   SINGLE-MONITOR INSTALLATION   Refer to Figure 1 and Table A for the following instructions.   1. Set the impedance switch on the back of the monitor to LO (75 ohms).   2. Connect a 75-ohm video cable from the video source, such as a camera, to the BNC connector labeled VIDEO IN (or   INPUT) on the back of the monitor.   3. Plug in the appropriate power cord.   Figure 1. Singe-Monitor   Installation (PMM15A Shown)   6 C2902M (10/02)   MULTIPLE-MONITOR INSTALLATION   Refer to Figure 2 and Table A for the following instructions.   1. Connect a 75-ohm video cable from the video source, such as a camera, to the BNC connector labeled VIDEO IN (or   INPUT) on the back of the first monitor.   2. Connect a 75-ohm video cable from the VIDEO OUT (or OUTPUT) connector on the back of the first monitor to the VIDEO   IN (or INPUT) connector on the second monitor.   3. If you are using a third monitor, connect a 75-ohm video cable from the VIDEO OUT (or OUTPUT) connector on the back of   the second monitor to the VIDEO IN (or INPUT) connector on the third monitor.   NOTE: In multiple-monitor installations, a maximum of three monitors can be connected together.   4. Set the impedance switch on the first monitor to HI.   If you are only using two monitors, set the impedance switch on the second monitor to LO (75 ohms).   If you are using three monitors, set the impedance switch on the second monitor to HI and on the third monitor to LO   (75 ohms).   5. Plug in the appropriate power cords for the monitors.   Figure 2. Multiple-Monitor Installation (PMM15A Shown)   Table A. Video Coaxial Cable Requirements   Cable Type*   Maximum Distance   RG59/U   RG6/U   750 ft (229 m)   1,000 ft (305 m)   1,500 ft (457 m)   RG11/U   * Minimum cable requirements:   75 ohms impedance   All-copper center conductor   All-copper braided shield with 95% braid coverage   C2902M (10/02)   7 OPERATION   Controls are located on the front of the monitor. On the PMM9A, PMM12A, and PMM15A, some or all of the controls are   behind a hinged cover. Refer to Figure 3.   Power On/Off Switch – This rocker switch turns the power on or off. Push the side with the white line to turn on the power.   Push the side with the white circle to turn the power off.   LED Power Indicator – The LED lights when power is turned on.   Brightness Control – This control adjusts the overall picture brightness to compensate for differences in room lighting.   Figure 3. Location of Controls (PMM15A Shown)   Contrast Control – This control adjusts the contrast   between the black and white portions of the picture. When   properly adjusted, you will be able to observe a fine   gradation between blacks, grays, and whites.   Vertical Hold Control (Except PMM20A) – This control   permits adjustment of vertical stability. If the picture “rolls”   upward or downward, as shown in Figure 4, turn the   VERTICAL HOLD clockwise or counterclockwise until the   picture stabilizes.   Horizontal Hold Control (Except PMM20A) – This   Figure 4. Vertical Roll   control permits adjustment of horizontal stability. If the   picture “tears” to the left or right, as shown in Figure 5, turn   the HORIZONTAL HOLD clockwise or counterclockwise until   the picture stabilizes.   To operate a monitor:   1. Make sure a standard 1.0 V peak-to-peak video signal   is applied to the video input of the monitor.   2. Press the power switch to turn on the power. The   power indicator LED will illuminate.   3. Adjust the brightness and contrast controls to obtain   optimum picture quality.   Figure 5. Horizontal Tear   8 C2902M (10/02)   MAINTENANCE   The only maintenance required is to clean the cabinet and screen periodically.   Use a damp cloth to clean the screen.   Use mild soap and water to clean the cabinet. Some common household aerosol sprays, cleaning agents, solvents, or polishes   may damage the cabinet finish. Dry the cabinet with a soft cloth.   C2902M (10/02)   9 SPECIFICATIONS   ELECTRICAL   Input Voltage:   96-256 VAC, 50/60 Hz, auto-ranging   Power Consumption   PMM9A:   28 W   30 W   35 W   48 W   PMM12A:   PMM15A:   PMM20A:   Input Signal:   Input Impedance:   Bandwidth:   0.5 to 2.0 Vp-p composite video   75 ohms or high (switchable)   100 Hz to 10 MHz   Resolution:   >1,000 lines   Linearity   Horizontal:   Vertical:   10% maximum   10% maximum   Operating System   EIA   Horizontal:15,750 Hz ±400 Hz   Vertical: 60 Hz   CCIR   Horizontal:15,625 Hz ±400 Hz   Vertical: 50 Hz   GENERAL   Environment:   Construction:   Finish:   Indoor   Steel cabinet with black plastic front   Black matte texture coat finish   Dimensions   PMM9A:   9.3 (H) x 8.7 (W) x 9.9 (D) inches (23.5 x 22.0 x 25.2 cm)   12.3 (H) x 12.2 (W) x 12.0 (D) inches (31.3 x 31.0 x 30.5 cm)   12.8 (H) x 14.3 (W) x 13.1 (D) inches (32.6 x 36.2 x 33.2 cm)   18.6 (H) x 19.3 (W) x 14.2 (D) inches (47.3 x 49.0 x 36.1 cm)   PMM12A:   PMM15A:   PMM20A:   Picture Tube   Dimension   PMM9A:   9 inches (22.86 cm), measured diagonally   12 inches (30.48 cm), measured diagonally   15 inches (38.10 cm), measured diagonally   20 inches (50.80 cm), measured diagonally   PMM12A:   PMM15A:   PMM20A:   Operating   Temperature:   32° to 122°F (0° to 50°C)   Storage   Temperature:   14° to 140°F (-10° to 60°C)   Relative Humidity: 10 to 95 percent, non-condensing   Weight   PMM9A:   10.45 lb (4.75 kg)   17.50 lb (7.94 kg)   24.15 lb (10.94 kg)   44.25 lb (20.08 kg)   PMM12A:   PMM15A:   PMM20A:   (Design and product specifications subject to change without notice.)   10   C2902M (10/02)   REGULATORY NOTICES   NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of   the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential   installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in   accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee   that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or   television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct   the interference by one or more of the following measures:   • • • Increase the separation between the equipment and the receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.   WARRANTY AND RETURN INFORMATION   WARRANTY   Pelco will repair or replace, without charge, any merchandise proved defective in material or   workmanship for a period of one year after the date of shipment. Exceptions to this warranty are   as noted below:   If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to   obtain a Repair Authorization number (RA), and provide the following information:   1. Model and serial number   • Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600   Series); two years on all other cameras.   2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number   3. Details of the defect or problem   • • • Three years on Genex® Series (multiplexers, server, and keyboard).   Two years on cameras and all standard motorized or fixed focal length lenses.   Two years on Legacy®, Camclosure® Camera Systems, CM6700/CM6800/CM8500/CM9500/   CM9740/CM9760 Matrix, DF5 and DF8 Series Fixed Dome products.   Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in continuous   motion applications.   If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions   stated above, please include a written explanation with the product when returned.   • Method of return shipment shall be the same or equal to the method by which the item was received by   Pelco.   • • • Two years on WW5700 series window wiper (excluding wiper blades).   Eighteen months on DX Series digital video recorders.   One year (except video heads) on video cassette recorders (VCRs). Video heads will be   covered for a period of six months.   Six months on all pan and tilts, scanners or preset lenses used in continuous motion applica-   tions (that is, preset scan, tour and auto scan modes).   RETURNS   In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-   9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA   number if returned for repair).   • All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.   Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco   shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,   California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident   are not covered under this warranty.   Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and   freight should be prepaid. Ship to the appropriate address below.   If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico:   Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the   specific use or application made of the Products. Pelco’s liability for any claim, whether based on   breach of contract, negligence, infringement of any rights of any party or product liability, relating   to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no   event will Pelco be liable for any special, incidental or consequential damages (including loss of   use, loss of profit and claims of third parties) however caused, whether by the negligence of   Pelco or otherwise.   Service Department   Pelco   3500 Pelco Way   Clovis, CA 93612-5699   If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico:   Intermediate Consignee   American Overseas Air Freight   320 Beach Road   Burlingame, CA 94010   USA   Ultimate Consignee   Pelco   3500 Pelco Way   Clovis, CA 93612-5699   USA   The above warranty provides the Dealer with specific legal rights. The Dealer may also have   additional rights, which are subject to variation from state to state.   REVISION HISTORY   Manual #   Date   Comments   C2902M   10/02   Original version.   ® Pelco, the Pelco logo, Spectra, Genex, Legacy, Esprit, and Camclosure are registered trademarks of Pelco.   C2902M (10/02)   © Copyright 2002, Pelco. All rights reserved.   11   ® World Headquarters   3500 Pelco Way   Clovis, California 93612 USA   USA & Canada   Tel: 800/289-9100   Fax: 800/289-9150   International   Tel: 1-559/292-1981   Fax: 1-559/348-1120   ISO9001   Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada   |