Miele KM 360 User Manual

Installation Instructions  
Gas cooktop  
KM 360  
®
UV  
M.-Nr. 06 390 460  
®
To prevent accidents and  
machine damage,  
read these instructions  
before installation or use.  
Contents  
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Appliance dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Setting the cooktop into place. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Securing the cooktop. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Gas connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Gas pressure regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Converting to another type of gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
3
IMPORTANT SAFETY INSTRUCTIONS  
Installation  
The minimum distances given in  
these Installation instructions are to  
combustible surfaces, and must be  
observed to ensure safe operation.  
Failure to do so increases the risk of  
fire.  
The cabinetry and venting hood  
should be installed first, to prevent  
damage to the cooktop.  
recommended  
Gas appliances should only be  
installed in a well ventilated area.  
The countertop must be bonded  
with heat resistant (212°F/100°C)  
adhesive to prevent distortion or  
dissolving.  
The cooktop should only be  
installed as shown, while  
maintaining the required safety  
distances shown. Do not install the  
cooktop between two tall cabinets, this  
is a fire hazard.  
not recommended  
a = minimum distance between the  
cooktop and a tall cabinet:  
12" (305 mm)  
This equipment has not been  
designed for maritime use or for  
use in mobile installations such as  
aircraft or recreational vehicles.  
However, under certain circumstances  
it may be possible for installation in  
these applications. Please contact the  
Miele Technical Service Department  
with specific requirements.  
not allowed  
4
IMPORTANT SAFETY INSTRUCTIONS  
The cooktop must not be installed  
Safety distances above the  
appliance  
over a dishwasher, washer, dryer,  
refrigerator or freezer. Heat radiated by  
the cooktop may damage them.  
Deep fat fryers must not be  
installed next to gas cooktops. Gas  
flames can ignite splattering oil. A  
distance of at least 12" (305 mm)  
should be maintained between these  
two appliances. The minimum distance  
between two cooktops must be 4"  
(100 mm).  
Install the appliance so that the  
power cord or gas piping does not  
come into contact with any portion of  
the cooktop which may become hot  
during use.  
There must be a safety distance of at  
least 30" (760 mm), b between the  
appliance and any objects above it.  
The overhead cabinet depth, c, if  
unprotected, must not exceed 13"  
(330 mm). The minimum distance of  
combustible surfaces located above  
and to the sides of the cooktop, d, is  
18" (457 mm).  
This appliance must be installed  
with its own shut off valve and the  
included gas pressure regulator.  
Both the valve and the regulator  
must be easily accessible to the  
consumer after the appliance is  
installed.  
If the cabinet manufacturer  
recommends a greater distance, follow  
that manufacturers recommendation.  
When installing the cooktop under a  
venting hood, always observe the  
minimum distance recommended by  
the hood manufacturer.  
This appliance must be  
disconnected from the gas supply  
during any pressure testing of the  
system performed in excess of ½ psi  
(3.5 kPa). This appliance must be  
isolated at test pressures equal to or  
less than ½ psi (3.5 kPa).  
Keep this instruction book in a safe  
place for future reference and pass it  
on to an future user.  
Any pipe connections must be made  
using a thread sealant approved for  
gas connections. Failure to correctly  
install these items could lead to a  
gas leak and subsequent explosion.  
5
Appliance dimensions  
a Built in depth  
b Electrical connection box  
c Gas connection R ½" NPT  
^ Rember to maintain the minimum safety distances to combustible surfaces:  
- 2 3/4" (70 mm) between the cooktop and the back wall and  
- 12" (305 mm) between the cooktop and a side wall or tall unit to the right or left  
of the cooktop.  
(See "Important Safety instructions").  
6
Installation  
Setting the cooktop into place  
Securing the cooktop  
^ Screw the gas regulator onto the  
nipple underneath the cooktop. For  
convenience, an AGA or CGA  
approved flexible stainless steel gas  
hose (accordion type) may be used  
between the gas connection and the  
regulator. For more information see  
"Gas connection - Gas pressure  
regulator".  
The included gas regulator must be  
installed between the cooktop and  
the gas shut off valve. If clearance  
for the regulator does not exist  
directly under the cooktop, it may be  
moved closer to the shut off valve.  
^ Secure the cooktop in position with  
the supplied fixing brackets, a.  
^ Guide the power cord through the  
cut-out.  
^ Set the cooktop in the cut-out and  
center it.  
The cooktop must not be  
permanently sealed into the  
countertop when installed.  
The sealing strip under the edge of  
the cooktop provides a sufficient  
seal for the countertop.  
If the cooktop is sealed into position,  
the countertop or appliance may be  
damaged if the cooktop needs to be  
removed for maintenance or service.  
7
Electrical connection  
This appliance must be electrically  
grounded. All electrical work should  
be performed by a qualified  
electrician in accordance with local  
or national codes and the:  
This appliance is equipped with a  
three-prong grounding plug to  
prevent shock hazards. It should be  
plugged directly into a properly  
grounded outlet. Do not cut or  
remove the grounding prong from  
the plug. If the plug does not fit the  
outlet, have a proper outlet installed  
by a licensed electrician.  
-
National Electrical Code  
ANSI / NFPA No. 70  
for the USA  
or  
-
Canadian Electrical Code Part I  
for Canada  
To guarantee the electrical safety of  
this appliance, continuity must exist  
between the appliance and an  
effective grounding system. It is  
imperative that this basic safety  
requirement be met. If there is any  
doubt, have the electrical system of  
the house checked by a qualified  
electrician.  
The manufacturer cannot be held  
responsible for damages caused by  
the lack, or inadequacy, of an  
effective grounding system.  
(CSA Standard C 22.2  
No. O-M91).  
,WARNING  
Disconnect the appliance from the  
main power supply before  
installation or service. To reduce the  
risk of electric shock, make sure that  
the appliance is properly grounded  
after installation.  
Power supply  
The automatic ignition requires that the  
cooktop be connected to a 120 VAC,  
60 Hz power supply. The supply line  
should be protected by a 15 A breaker.  
Note to the installer  
Please leave these instructions with the  
consumer or the appliance.  
Actual power consumption (during  
ignition only) is 25 W.  
This appliance is equipped with a 4 ft.  
(1.2 m) long power cord that is ready  
for connection to the appropriate outlet.  
Please place the power outlet so that it  
is accessible after the appliance has  
been installed in the countertop.  
8
Gas connection  
Installation and service must be  
performed by a qualified installer,  
service agency or the gas supplier.  
The gas connection must be made  
in accordance with local codes or in  
the absence of local codes with:  
In Massachusetts a licensed  
plumber/gas fitter is required.  
-
the National Fuel Gas Code,  
ANSI Z 21.1 for the USA  
or  
-
This appliance must be installed  
with its own shut off valve and the  
included gas pressure regulator.  
Both the valve and the regulator  
must be easily accessible to the  
consumer to turn on or shut off the  
gas supply after the appliance is  
installed.  
the current Can / CGA  
Interim #58-M95  
and .2 Installation Codes for gas  
burning appliances for Canada.  
Make sure that the maximum gas  
supply pressure, before the gas  
pressure regulator, is never more than  
1/2 psi (3.5 kPa) for natural gas or LP  
gas.  
This appliance and its individual  
shut off valve must be disconnected  
from the gas supply during any  
pressure testing of the system  
performed in excess of 1/2 psi  
(3.5 kPa). The machine must be  
isolated from the gas supply line by  
closing its individual manual shut off  
valve at test pressures equal to or  
less than 1/2 psi (3.5 kPa).  
The minimum supply pressure to get  
the required gas input is  
6" w.c. for natural gas  
10" w.c. for LP gas.  
Any pipe connections must be made  
using a thread sealant approved for  
gas connections. Failure to correctly  
install these items could lead to a  
gas leak and subsequent explosion.  
9
Gas connection  
Gas pressure regulator  
For convenience, an AGA or CGA  
approved flexible stainless steel gas  
hose (accordion type) may be used  
between the gas connection and the  
regulator. This will allow the appliance  
to be lifted out of the countertop for  
cleaning or servicing. Make sure that  
any drawers, cabinet doors, etc., do not  
rub on this gas hose.  
A pressure regulator that is convertible  
from natural to LP gas (Propane) or vice  
versa is included with the appliance.  
The included regulator corresponds  
with the gas type of the cooktop. Verify  
before installing.  
The adjusted pressure is:  
natural gas - 4" w.c.  
LP gas - 10" w.c.  
Do not use any regulator unless it  
has been supplied by Miele. Doing  
so may cause a gas leak.  
If there is any doubt concerning  
installation contact the Miele Technical  
Service Department:  
U 1-800-999-1360  
V 1-800-565-6435  
After connecting the appliance check  
all fittings for gas leaks e.g. with  
soapy water.  
aCooktop  
b½" NPT  
cRegulator  
When installed properly, the flame will  
be steady and quiet. It will also have a  
sharp, blue inner core that will vary in  
length proportional to the burner size.  
Flame adjustment will not be necessary.  
As shown in the above diagram, the  
included regulator must be used when  
connecting the Miele cooktop to your  
gas supply. This item has been  
customized by Miele to meet all  
applicable safety requirements. Make  
sure the regulator is easily accessible  
for adjustment after the appliance has  
been installed.  
10  
Gas connection  
Nominal Rating Table  
NG (Natural gas)  
LP (Liquid propane gas)  
Auxiliary burner  
Max. output  
Min. output  
BTU/hr  
kW  
1.0  
3400  
900  
0.26  
Normal burner  
Max. output  
Min. output  
6000  
1200  
1.76  
0.35  
Fast burner  
Max. output  
Min. output  
10200  
1700  
3.0  
0.5  
All burners  
Max. output  
25600  
7.5  
11  
Converting to another type of gas  
The cooktop should have been ordered  
for connection to either natural gas or  
LP gas (propane).  
If the cooktop is not configured for the  
proper type of gas connection please  
contact your Miele Dealer.  
If the appliance is to be connected to a  
type of gas other than it was originally  
configured for, both the regulator and  
burners must be converted. A  
conversion kit is available as an  
optional accessory from the Miele  
Technical Service Department.  
12  
13  
14  
15  
Alterations rights reserved / 3606  
M.-Nr. 06 390 460 / 06  
en - USA  

Intel M1920 User Manual
JVC GD V4210PZW G User Manual
KitchenAid KECC508RPS02 User Manual
Magnavox 27MS3404R User Manual
Panasonic Cordless Telephone KX TG7873 User Manual
Panasonic TC 25V70T User Manual
Philips 14PT1686V User Manual
Philips 21PT4429 User Manual
Philips Magnavox 19PR 21C User Manual
Philips SE6554B User Manual