SEQUENCE OF OPERATION
IMPINGER X2 OVENS
3240-2*
3262-2*
3270-2*
230VAC
230VAC
230VAC
50 HZ.
50 HZ.
50 HZ.
1 PHASE
1 PHASE
1 PHASE
*NOTE:
Model number ending in TS indicates top belt is split belt
Model number ending in SB indicates bottom belt is split belt
Model number ending in SS indicates both belts are split belts
POWER SUPPLY
Electrical power to be supplied to the oven by a three conductor service for single phase
or a five conductor service for three phase.
Black conductor is hot.
Red conductor is hot.
Orange conductor is hot.
White conductor is neutral.
Green conductor is ground.
MAIN FAN CIRCUIT
BURNER CIRCUIT
Power is permanently supplied to the normally open contacts of the main fan relay.
Power is also supplied, through a 2 amp. fuse, to the 30 minute time delay relay.
Closing the oven fan switch enables the 30 minute time delay relay. The 30 minute time
delay relay supplies 220/240VAC to the coil of the main fan relay. These normally open
contacts now close energizing the main fan motor. Closing the main fan switch also
supplies 220/240VAC to the burner and conveyor switches.
Closing the main fan switch supplies 220/240VAC to the normally open burner switch.
Closing the burner switch supplies 220/240VAC, through the EMI filter, to the electronic
temperature control. 220/240VAC is supplied, through the air pressure switch and the
oven cavity hi-limit thermostat, to the burner control. When the burner control is
energized, 220/240VAC is supplied to the burner blower motor. The normally open air
pressure switch closes upon sensing air pressure. After a pre-purge of 30 seconds, the
pilot valve and spark are energized. Ignition should now occur. After the pilot flame is
proven, the main valve is energized.
TEMPERATURE CONTROL
CONVEYOR DRIVE
Closing the main fan switch and burner switch supplies 220/240VAC to the electronic
temperature control. The electronic temperature control is adjusted to the desired
temperature. The thermocouple will provide varying millivolts to the electronic
temperature control. The temperature control supplies 220/240VAC to the temperature
regulation valve at intermittent intervals to maintain desired temperature.
THE OVEN WILL CONTAIN BETWEEN TWO AND FOUR SEPARATE CONVEYOR
DRIVE SYSTEMS. THE SEQUENCE OF OPERATIONS WILL BE THE SAME FOR
EACH MOTOR SYSTEM.
Closing the main fan switch supplies 220/240VAC, through the EMI filter, to the normally
open conveyor switch, through a 2 Amp. fuse, to the conveyor control. AC voltage is
converted to DC voltage and DC voltage is supplied, at terminals A+ and A-, to the
conveyor motor. Adjusting the conveyor control will vary the DC output voltage. The
speed of the motor will increase or decrease as the DC voltage from the conveyor
control increases or decreases.
NOTE: The conveyor control uses a hall effect sensor and magnet, mounted on the conveyor
motor that senses motor speed. The sensor detects any change in motor load (± RPM)
and the voltage to the motor is adjusted accordingly.
AUTOMATIC COOL DOWN
When the oven is started, the 30 minute time delay relay is enabled, permitting the oven
fan to operate for approximately 30 minutes after the oven is shut off, to cool the oven.
When the oven is shut off, the 30 minute time delay relay will keep the coil of the main
fan relay closed for 30 minutes, maintaining operation of the main fan motor.
Impinger X2 – Analog Service Manual – Dom & Int’l
3
SCHEMATIC DIAGRAM
MODEL 3240-2, 3262-2, 3270-2 60 HZ.
4
Impinger X2 – Analog Service Manual – Dom & Int’l
SCHEMATIC DIAGRAM
MODEL 3240-2, 3262-2, 3270-2 50 HZ.
Impinger X2 – Analog Service Manual – Dom & Int’l
5
TROUBLESHOOTING GUIDE
3240-2*
3240-2*
3262-2*
3262-2*
3270-2*
3270-2*
120/230VAC
120/230VAC
120/230VAC
120/230VAC
120/230VAC
120/230VAC
60 HZ.
60 HZ.
60 HZ.
60 HZ.
60 HZ.
60 HZ.
1 PHASE
3 PHASE
1 PHASE
3 PHASE
1 PHASE
3 PHASE
*NOTE:
Model number ending in TS indicates top belt is split belt
Model number ending in SB indicates bottom belt is split belt
Model number ending in SS indicates both belts are split belts
SYMPTOM
Oven fan will not run
POSSIBLE CAUSE
Incoming power supply
EVALUATION
Check circuit breakers. Reset if required. Call power
co. if needed.
Fuse, 2 Amp, control (F7)
Fuse holder
Switch, oven fan
Check, replace if necessary.
Check, replace if necessary.
Check continuity between switch terminals. Replace
switch as needed.
30 minute time delay relay
Check for supply voltage to 30 minute time delay relay
at terminals #2 and #3. If no voltage is present, trace
wiring back to main power switch. If there is supply
voltage at terminals #2 and #3, check for output voltage
at terminals #1 and #3. If there is incoming voltage but
no output voltage, and the main power switch is on,
replace the 30 minute time delay relay.
Relay, main fan
Check for supply voltage to relay contacts, if no voltage
is present, trace wiring back to power supply. Check for
120VAC to the coil of the main fan relay. If no voltage is
present, trace wiring back to the 30 minute time delay
relay, check to be sure that the Overload Protector
contacts are closed. If contacts are open, see
“Overload Protector” below. If voltage is present, check
to insure relay contacts are closing. Replace relay as
needed.
Overload protector, main fan
Check to be sure overload contacts are closed. If not
closed, re-set overload. If contacts do not close,
replace overload protector. If contacts close, test for
proper operation. If the overload contacts do not stay
closed, and the amperage is below the overload
setting, replace the overload protector.
3240 should be set at 13A
3260 should be set at 18A
3270 should be set at 18A
Main fan motor
Capacitor
Check for supply voltage at motor. If no voltage is
present, trace wiring back to the overload protector.
WITH POWER OFF: Check for opens, shorts or
grounds. Turn motor shaft to check for locked rotor.
Check for shorts or grounds.
WARNING: Capacitor has a stored charge, discharge
before testing.
Check for loose or broken drive belt. Adjust motor for
proper belt tension (maximum of 3/8-inch deflection), or
replace drive belt as needed.
Drive belt
Bearings, Fan shaft
Check for any damage or excessive wear on the shaft
Impinger X2 – Analog Service Manual – Dom & Int’l
6
bearings. Replace bearings as needed.
Check for adequate gas supply to oven.
Oven will not heat
Gas supply
Manual gas shut off valve
Check to see that the manual gas shut off valve is
open. Also, check flexible gas line connection for any
damage.
Main fan motor
Relay, main fan
Check for main fan operation. If it is not operating, refer
to “Oven fan will not run”.
Check for 120VAC supplied to relay terminal #13. If
voltage is not present, trace wiring back to power
supply. If voltage is present, check for 120VAC at
terminal #14. If there is no voltage at terminal #14, and
the relay is energized, replace the main fan relay.
Check, replace if necessary.
Fuse, 2 Amp, control (F8)
Fuse holder
Check, replace if necessary.
Switch, oven fan
Check for 120VAC to the switch, if no voltage is
present, trace wiring back to the main fan relay. Check
continuity between switch terminals. Replace switch as
needed.
Switch, burner
Check for 120VAC to the switch, if no voltage is
present, trace wiring back to the oven fan switch.
Check continuity between switch terminals. Replace
switch as needed.
Air pressure switch
Check for 120VAC to the air pressure switch. If no
voltage is present, trace wiring back to burner switch.
This normally open switch should close when the main
fan is activated. Check air switch tube for blockage or
any obstructions, repair as needed. Refer to the
“Removal and installation” section for proper
adjustment of air pressure switch. Replace air pressure
switch as needed.
Transformer, burner
Relay, burner blower
Check for 120VAC supplied to primary of transformer. If
no voltage is present, trace wiring back to the air
pressure switch. If voltage is present, check for 24VAC
at transformer secondary. If there is primary voltage but
no secondary voltage, replace burner transformer.
Check for 24VAC supply to relay coil. If no voltage is
present, trace wiring back to burner transformer. Check
for 120VAC to relay contact. If no voltage is present,
trace wiring back to air pressure switch. When 24VAC
is applied to the coil, there will be a delay of 20 – 30
seconds. After this time delay, the relay contacts
should close. If there is 24VAC applied, but the
contacts do not close, replace the burner blower relay.
Check for 120VAC supplied to the burner blower motor.
If no voltage is present, trace wiring back to the burner
blower relay. If voltage is present, and the motor is not
turning, check for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Replace burner blower motor as needed.
Motor, burner blower
Centrifugal switch of
Burner blower motor
Check for 24VAC supplied to centrifugal switch at wire
S5. If no voltage is present, trace wiring back to the
burner transformer. If voltage is present, check for
24VAC out of centrifugal switch at wire #32. If there is
voltage in, but there is no voltage out, and the burner
blower motor is running, replace the burner blower
motor.
Burner control
Check for 24VAC supplied to the burner control at
terminals #5 and #6. If no voltage is present, trace
Impinger X2 – Analog Service Manual – Dom & Int’l
7
wiring back to the centrifugal switch of the burner
blower motor. If voltage is present, check for 24VAC at
pins #3 and #2 (pilot valve). If voltage is not present,
replace burner control. If the pilot valve is energized,
check to see that the high voltage igniter circuit is also
energized. To check, turn power off, disconnect the
igniter lead from the ignition control. Turn power on. If
no spark is visible, replace burner control. If a spark is
visible at burner control, proceed.
Check for 24VAC supplied to pilot valve. If no voltage is
present, trace wiring back to burner control. If voltage is
present, check for gas pressure at the pilot line
connection. If no gas pressure is present during
ignition, check for any blockage in the assembly. If
there are no obstructions, and there is gas supplied to
the oven, replace the gas valve.
Pilot valve
No pilot flame
Pilot tube
If the ignition control is supplied with 24VAC and the
pilot valve and igniter circuits are energized, visually
check for a pilot flame. This may be done by looking
through the inspection view port on the end of the
burner. If no pilot flame is visible, check the pilot tube.
Check for gas pressure at the pilot tube. Disconnect
pilot tube at the burner And connect manometer to pilot
tube. If no gas pressure is present during ignition,
check for blockage of the pilot tube. If the pilot tube is
clear, proceed.
Pilot orifice
If there is gas pressure at the pilot tube, check the pilot
orifice for blockage or obstructions. Replace pilot orifice
as needed.
Burner igniter
Check the burner igniter head for any damage or
obstructions also check for frayed or broken wire.
Check spark gap, gap should be 3/32” If there is visible
damage, replace burner igniter.
NOTE: Flame should be
On at this time
Electronic temperature
control
Pilot flame, but no main flame
Check for 120VAC supplied to electronic temperature
control at terminals #13 and #12. Of there is no voltage,
trace wiring back to the burner switch. Also check for
120VAC supplied to terminal #20 on the electronic
temperature control. If there is no voltage at terminal
#20, trace wiring back to terminal #13. Set temperature
control to maximum temperature and check for
120VAC output at terminal #21 and neutral. If 120VAC
is present at terminal #20 and neutral, and the unit is
not heating, refer to “Temperature regulation valve” for
next check. If 120 VAC is not present, proceed.
WITH POWER ON AND THERMOCOUPLE LEADS
ATTACHED TO THE ELECTRONIC TEMPERATURE
CONTROL: Measure the D.C. millivolt output of these
leads. Refer to chart in the “Removal, Installation and
Adjustment” section for proper readings. If these
readings are not achieved, replace thermocouple.
Check for 24VAC supplied to main valve. If no voltage
is present, trace wiring back to burner control. If there is
no voltage output, replace burner control.
Check to see that the switch on the valve is in the “ON”
position. Check for 24VAC supplied to main valve. If
there is voltage present, check to see that valve is
opening. Connect manometer to pressure tap on outlet
side of valve. If there is voltage to the valve, but no
output gas pressure, replace the valve.
Thermocouple probe
Burner control.
Main gas valve
8
Impinger X2 – Analog Service Manual – Dom & Int’l
Temperature regulation valve If 120VAC is present on the electronic temperature
control, terminal #13 to neutral, check for voltage at
temperature regulation valve. If no voltage is present,
trace wiring back to electronic temperature control. If
voltage is present, listen for valve to open and close.
Also check for opens or shorts in the operating coil.
Replace temperature regulation valve as needed.
Thermal/Overload of main fan The main fan motor and burner blower motor are
Intermittent heating
Conveyor will not run
and burner blower motors
equipped with internal thermal protection and will cease
to operate if overheating occurs. As the motors over-
heat and then cool, this will cause the units to cycle on
and off intermittently. Improper ventilation or lack of
preventive maintenance may cause this. Also, most of
the problems listed under “Oven will not heat” can
cause intermittent failure.
NOTE: The ovens may contain two, three or four conveyor drive systems using like
components. The trouble shooting sequence will be the same for each of the conveyor
drive systems
Power supply
Check circuit breakers, reset if required. Check power
plug to be sure it is firmly in receptacle. Measure
incoming power, call power co. if needed.
Switch, oven fan
Relay, main fan
Check continuity between switch terminals. Replace
switch as needed.
Check for 120VAC supplied to relay terminal #13. If
voltage is not present, trace wiring back to power
supply. If voltage is present, check for 120VAC at
terminal #14. If there is no voltage at terminal #14, and
the relay is energized, replace the main fan relay.
Check, replace if necessary.
Check for 120VAC supplied to fuse holder. If no voltage
is present, trace wiring back to main fan relay. Check
fuse holder, replace if necessary.
Fuse, 2 Amp
Fuse holder
Switch, conveyor
Control, conveyor
Check for 120VAC supplied to conveyor switch. If no
voltage is present, trace wiring back to fuse holder.
Check continuity between switch terminals. Replace
switch as needed.
Check for 120VAC supplied to conveyor control at
terminals #1 (AC) and #2 (AC). If no voltage is present,
trace wiring back to conveyor switch. If AC voltage is
present, check for DC voltage output at terminals #3
(A-) and #4 (A+). If there is AC voltage in, but no DC
voltage out of the conveyor control. Replace the
conveyor control. If there is D.C. voltage output,
proceed.
Fuse, 2 Amp
Fuse holder
Check, replace if necessary.
Check for D.C. voltage supplied to fuse holder. If no
voltage is present, trace wiring back to conveyor
control. Check fuse holder, replace if necessary.
Check for D.C. voltage supplied to the reversing switch.
If no voltage is present, trace wiring back to the fuse
holder. Check continuity between switch terminals.
Replace switch as needed.
Check for D.C. voltage to the conveyor motor. If no
voltage is present, trace wiring back to the reversing
switch. If voltage is present and the motor will not run,
check the motor windings for opens or shorts. Check
motor brushes for excessive wear. Replace motor
brushes as needed.
Switch, conveyor reversing
Conveyor motor
If any of the above fails, replace conveyor motor.
Check for any mechanical problems in the conveyor
Conveyor
Impinger X2 – Analog Service Manual – Dom & Int’l
9
assembly. Check for damaged or torn belting. Check
conveyor shaft bearings for damage or excessive wear.
Repair or replace conveyor components as needed.
Check for a steady 120VAC supply to the conveyor
control. If voltage is not steady, trace back to power
supply.
Check for a steady DC voltage output at terminals A+
and A-. If voltage is not steady, proceed. Check for
5 VDC output from the conveyor control at terminals
+5V(red) and COM (black). If there is no voltage output,
replace the conveyor control. If there is DC output,
proceed.
Conveyor speed varying or
intermittent
Power supply
Control, conveyor
Motor, conveyor
Check conveyor motor and gearbox for any visible
damage. If there is apparent damage, repair or replace
conveyor motor. Check motor brushes for excessive or
abnormal wear. Replace motor brushes as needed.
Check to be sure that the Hall effect sensor and
magnet are mounted on the motor. Check for any
visible damage to the Hall effect sensor and magnet. If
there is visible damage, repair or replace as needed. If
there is no visible damage, check for a frequency
output from the hall effect sensor at terminals SIG
(white) and COM (black).
Hall effect sensor/magnet
Readings should be as follows:
2:15 cook time
5:00
56 Hz. approx.
25 Hz. approx.
13 Hz. approx.
8 Hz. approx.
10:00
16:00
If these readings are not achieved, replace the Hall
effect sensor/magnet
10
Impinger X2 – Analog Service Manual – Dom & Int’l
TROUBLESHOOTING GUIDE
3240-2*
3262-2*
3270-2*
230VAC
230VAC
230VAC
50 HZ.
50 HZ.
50 HZ.
1 PHASE
1 PHASE
1 PHASE
*NOTE:
Model number ending in TS indicates top belt is split belt
Model number ending in SB indicates bottom belt is split belt
Model number ending in SS indicates both belts are split belts
SYMPTOM
Oven fan will not run
POSSIBLE CAUSE
Incoming power supply
EVALUATION
Check circuit breakers. Reset if required. Call power
co. if needed.
Fuse, 2 Amp, control (F7)
Fuse holder
Switch, oven fan
Check, replace if necessary.
Check, replace if necessary.
Check continuity between switch terminals. Replace
switch as needed.
30 minute time delay relay
Check for supply voltage to 30 minute time delay relay
at terminals #2 and #3. If no voltage is present, trace
wiring back to main power switch. If there is supply
voltage at terminals #2 and #3, check for output voltage
at terminals #1 and #3. If there is incoming voltage but
no output voltage, and the main power switch is on,
replace the 30 minute time delay relay.
Relay, main fan
Check for supply voltage to relay contacts, if no voltage
is present, trace wiring back to power supply. Check for
supply voltage to the coil of the main fan relay. If no
voltage is present, trace wiring back to the 30 minute
time delay relay, check to be sure that the Overload
Protector contacts are closed. If contacts are open, see
“Overload Protector” below. If voltage is present, check
to insure relay contacts are closing. Replace relay as
needed.
Overload protector, main fan
Check to be sure overload contacts are closed. If not
closed, re-set overload. If contacts do not close,
replace overload protector. If contacts close, test for
proper operation. If the overload contacts do not stay
closed, and the amperage is below the overload
setting, replace the overload protector.
3240 should be set at 13A
3260 should be set at 18A
3270 should be set at 18A
Main fan motor
Capacitor
Check for supply voltage at motor. If no voltage is
present, trace wiring back to the overload protector.
WITH POWER OFF: Check for opens, shorts or
grounds. Turn motor shaft to check for locked rotor.
Check for shorts or grounds.
WARNING: Capacitor has a stored charge, discharge
before testing.
Check for loose or broken drive belt. Adjust motor for
proper belt tension (maximum of 3/8-inch deflection), or
replace drive belt as needed.
Drive belt
Bearings, Fan shaft
Check for any damage or excessive wear on the shaft
bearings. Replace bearings as needed.
Impinger X2 – Analog Service Manual – Dom & Int’l
11
Oven will not heat
Gas supply
Manual gas shut off valve
Check for adequate gas supply to oven.
Check to see that the manual gas shut off valve is
open. Also, check flexible gas line connection for any
damage.
Main fan motor
Relay, main fan
Check for main fan operation. If it is not operating, refer
to “Oven fan will not run”.
Check for supply voltage to relay terminal #13. If
voltage is not present, trace wiring back to power
supply. If voltage is present, check for supply voltage at
terminal #14. If there is no voltage at terminal #14, and
the relay is energized, replace the main fan relay.
Check, replace if necessary.
Fuse, 2 Amp, control (F8)
Fuse holder
Check, replace if necessary.
Switch, oven fan
Check for supply voltage to the switch, if no voltage is
present, trace wiring back to the main fan relay. Check
continuity between switch terminals. Replace switch as
needed.
Switch, burner
Check for supply voltage to the switch, if no voltage is
present, trace wiring back to the oven fan switch.
Check continuity between switch terminals. Replace
switch as needed.
Air pressure switch
Check for supply voltage to the air pressure switch. If
no voltage is present, trace wiring back to burner
switch. This normally open switch should close when
the main fan is activated. Check air switch tube for
blockage or any obstructions, repair as needed. Refer
to the “Removal and installation” section for proper
adjustment of air pressure switch. Replace air pressure
switch as needed.
Thermostat, hi-limit
Burner control
Terminals are normally closed. If open, reset and test
oven for proper operation. If thermostat will not hold for
maximum oven temperature, and oven is not exceeding
temperature control setting, check for proper location of
capillary tube in the oven cavity. If above checks okay,
replace hi-limit thermostat.
Check for supply voltage to the burner control at
terminals #1 and #3. If no voltage is present, trace
wiring back to the hi-limit thermostat. If voltage is
present, check for supply voltage at pins #8 and #3
(burner blower motor). If voltage is not present, replace
burner control. If voltage is present, proceed.
Check for supply voltage to the burner blower motor. If
no voltage is present, trace wiring back to the burner
control. If voltage is present, and the motor is not
turning, check for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Replace burner blower motor as needed.
Motor, burner blower
Air pressure switch
(burner motor)
Check for supply voltage at the COM terminal on the air
pressure switch. If no voltage is present, trace wiring
back to burner control. If voltage is present, check for
supply voltage switching to the NO terminal on the air
pressure switch. If the burner blower motor is running,
but voltage is not switching to the NO terminal of the air
pressure switch, check air switch tube for blockage or
any obstructions, repair as needed. Refer to the
“Removal and installation” section for proper
adjustment of air pressure switch. Replace air pressure
switch as needed.
12
Impinger X2 – Analog Service Manual – Dom & Int’l
Burner control
Pilot valve
Check for supply voltage at terminal #7 on burner
control. If no voltage is present, trace wiring back to air
pressure switch. If voltage is present, check for output
voltage (after the 30 second delay) from terminal #8 on
the burner control. If there is no output voltage from
terminal #8, (after the 30 second delay) replace the
burner control. If there is output voltage, proceed.
Check for supply voltage to pilot valve. If no voltage is
present, trace wiring back to burner control. If voltage is
present, check for gas pressure at the pilot line
connection. If no gas pressure is present during
ignition, check for any blockage in the assembly. If
there are no obstructions, and there is gas supplied to
the oven, replace the gas valve.
Burner control
Check to see that the high voltage igniter circuit on the
burner control is energized. To check, turn power off,
disconnect the igniter lead from the burner control. Turn
power on. If no spark is visible, replace burner control.
If a spark is visible at burner control, proceed.
Check the burner igniter head for any damage or
obstructions also check for frayed or broken wire.
Check spark gap, gap should be 3/32” If there is visible
damage, replace burner igniter.
If there is supply voltage to the burner control, and the
pilot valve and igniter circuits are energized, visually
check for a pilot flame. This may be done by looking
through the inspection view port on the end of the
burner. If no pilot flame is visible, check the pilot tube.
Check for gas pressure at the pilot tube. Disconnect
pilot tube at the burner and connect manometer to pilot
tube. If no gas pressure is present during ignition,
check for blockage of the pilot tube. If the pilot tube is
clear, proceed.
Burner igniter
No pilot flame
Pilot tube
Pilot orifice
If there is gas pressure at the pilot tube, check the pilot
orifice for blockage or obstructions. Replace pilot orifice
as needed.
Burner igniter
Check the burner igniter head for any damage or
obstructions also check for frayed or broken wire.
Check spark gap, gap should be 3/32” If there is visible
damage, replace burner igniter.
Flame sensor
(There should be a visible pilot flame at this time.)
To check for proper flame sensor operation, connect a
digital multimeter (capable of measuring D.C. micro
amps) in series between the flame sensor wire
(normally connected to terminal #13 on the burner
control) and terminal #13 on the burner control. With a
visible pilot flame, the current reading should be 0.7
micro amp minimum. NOTE: The D.C. micro amp test
must be conducted with the oven in low flame operation
only. If these values are not achieved, replace flame
sensor. Also check for any type of damage to flame
sensor wire and connections.
Power supply
Burner control
If there is a pilot flame, and there is sufficient micro
amp. current, but the flame will not stay on, check for
proper polarity of the power supply.
If there is sufficient micro amp current, and there is
proper polarity of the power supply, but the burner will
not stay on, check the reset button for the burner
control. If the reset switch checks okay, replace the
burner control.
Pilot flame, but no main flame
Impinger X2 – Analog Service Manual – Dom & Int’l
NOTE: Flame should be
Check for supply voltage to electronic temperature
13
On at this time
Electronic temperature
control
control at terminals #13 and #12. Of there is no voltage,
trace wiring back to the burner switch. Also check for
supply voltage to terminal #20 on the electronic
temperature control. If there is no voltage at terminal
#20, trace wiring back to terminal #13. Set temperature
control to maximum temperature and check for output
voltage at terminal #21 and neutral. If voltage is present
at terminal #20 and neutral, and the unit is not heating,
refer to “Temperature regulation valve” for next check.
If voltage is not present, proceed.
Thermocouple probe
WITH POWER ON AND THERMOCOUPLE LEADS
ATTACHED TO THE ELECTRONIC TEMPERATURE
CONTROL: Measure the D.C. millivolt output of these
leads. Refer to chart in the “Removal, Installation and
Adjustment” section for proper readings. If these
readings are not achieved, replace thermocouple.
Check for supply voltage to main valve. If no voltage is
present, trace wiring back to burner control. If there is
no voltage output, replace burner control.
Check for supply voltage to main valve. If there is
voltage present, check to see that valve is opening.
Connect manometer to pressure tap on outlet side of
valve. If there is voltage to the valve, but no output gas
pressure, replace the valve.
Burner control.
Main gas valve
Temperature regulation valve If supply voltage is present on the electronic
temperature control, terminal #13 to neutral, check for
voltage at temperature regulation valve. If no voltage is
present, trace wiring back to electronic temperature
control, terminal #20. If voltage is present, listen for
valve to open and close. Also check for opens or shorts
in the operating coil. Replace temperature regulation
valve as needed.
Intermittent heating
Conveyor will not run
Thermal/Overload of main fan The main fan motor and burner blower motor are
and burner blower motors
equipped with internal thermal protection and will cease
to operate if overheating occurs. As the motors over-
heat and then cool, this will cause the units to cycle on
and off intermittently. Improper ventilation or lack of
preventive maintenance may cause this. Also, most of
the problems listed under “Oven will not heat” can
cause intermittent failure.
NOTE: The ovens may contain two, three or four conveyor drive systems using like
components. The trouble shooting sequence will be the same for each of the conveyor
drive systems
Power supply
Check circuit breakers, reset if required. Check power
plug to be sure it is firmly in receptacle. Measure
incoming power, call power co. if needed.
Switch, oven fan
Relay, main fan
Check continuity between switch terminals. Replace
switch as needed.
Check for supply voltage to relay terminal #13. If
voltage is not present, trace wiring back to power
supply. If voltage is present, check for supply voltage at
terminal #14. If there is no voltage at terminal #14, and
the relay is energized, replace the main fan relay.
Check, replace if necessary.
Check for supply voltage to fuse holder. If no voltage is
present, trace wiring back to main fan relay. Check fuse
holder, replace if necessary.
Fuse, 2 Amp
Fuse holder
Switch, conveyor
Check for supply voltage to conveyor switch. If no
voltage is present, trace wiring back to fuse holder.
Check continuity between switch terminals. Replace
Impinger X2 – Analog Service Manual – Dom & Int’l
14
switch as needed.
Control, conveyor
Check for supply voltage to conveyor control at
terminals #1 (AC) and #2 (AC). If no voltage is present,
trace wiring back to conveyor switch. If AC voltage is
present, check for DC voltage output at terminals #3
(A-) and #4 (A+). If there is AC voltage in, but no DC
voltage out of the conveyor control. Replace the
conveyor control. If there is D.C. voltage output,
proceed.
Fuse, 2 Amp
Fuse holder
Check, replace if necessary.
Check for D.C. voltage supplied to fuse holder. If no
voltage is present, trace wiring back to conveyor
control. Check fuse holder, replace if necessary.
Check for D.C. voltage supplied to the reversing switch.
If no voltage is present, trace wiring back to the fuse
holder. Check continuity between switch terminals.
Replace switch as needed.
Check for D.C. voltage to the conveyor motor. If no
voltage is present, trace wiring back to the reversing
switch. If voltage is present and the motor will not run,
check the motor windings for opens or shorts. Check
motor brushes for excessive wear. Replace motor
brushes as needed.
Switch, conveyor reversing
Conveyor motor
If any of the above fails, replace conveyor motor.
Check for any mechanical problems in the conveyor
assembly. Check for damaged or torn belting. Check
conveyor shaft bearings for damage or excessive wear.
Repair or replace conveyor components as needed.
Check for a steady supply voltage to the conveyor
control. If voltage is not steady, trace back to power
supply.
Check for a steady DC voltage output at terminals A+
and A-. If voltage is not steady, proceed. Check for
5 VDC output from the conveyor control at terminals
+5V(red) and COM (black). If there is no voltage output,
replace the conveyor control. If there is DC output,
proceed.
Conveyor
Conveyor speed varying or
intermittent
Power supply
Control, conveyor
Motor, conveyor
Check conveyor motor and gearbox for any visible
damage. If there is apparent damage, repair or replace
conveyor motor. Check motor brushes for excessive or
abnormal wear. Replace motor brushes as needed.
Check to be sure that the Hall effect sensor and
magnet are mounted on the motor. Check for any
visible damage to the Hall effect sensor and magnet. If
there is visible damage, repair or replace as needed. If
there is no visible damage, check for a frequency
output from the hall effect sensor at terminals SIG
(white) and COM (black).
Hall effect sensor/magnet
Readings should be as follows:
2:15 cook time
5:00
56 Hz. approx.
25 Hz. approx.
13 Hz. approx.
8 Hz. approx.
10:00
16:00
If these readings are not achieved, replace the Hall
effect sensor/magnet
Impinger X2 – Analog Service Manual – Dom & Int’l
15
REMOVAL, INSTALLATION & ADJUSTMENTS
IMPINGER X2 SERIES OVENS
CAUTION!
BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER X2
OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY
MOTOR, MAIN FAN - REPLACEMENT
1.
2.
3.
4.
5.
Shut off power at main breaker.
Remove control box cover and control box rear cover.
Disconnect motor wiring and mark all wiring for reassembly.
Remove V-belt by loosening the four bolts on the motor mount plate and the two belt tensioning bolts.
Remove motor and motor mount assembly. Remove motor from motor mount. Remove pulley from motor
and install pulley on new motor.
6.
Reassemble in reverse order and check system operation. Be sure to check for proper tension on drive
belt. Adjust tension bolts until there is no more than 3/8 inch deflection at the halfway point between the
motor pulley and the driven pulley.
SHAFT AND BLOWER WHEEL – REPLACEMENT
1. Shut off power at main breaker.
2. Remove cover panels form both sides.
3. Remove back.
4. Unbolt blower housings
5. Remove thermocouple from mount
6. Remove flanges from blower housing
( mark position of flange for replacement)
7. Unbolt air return panels from inside top
8. Remove sheet metal from plenum
16
Impinger X2 – Analog Service Manual – Dom & Int’l
9. Remove burner tube bracket
and Burner tube.
To remove burner tube,
Remove cap from idle end of
Oven wall and remove burner tube.
10. Measure distance from end of shaft to the collar
11. of blower wheel. Loosen blower wheels from shaft.
(1/4" allen screws - use liquid wrench)
Push blower wheels toward idle end.
12.Loosen and remove idle and drive end bearings.
13.Remove shaft and blower wheel assembles.( measure length of
shaft extension from oven wall. Use same measurement when
putting new shaft in)
Remove shaft through idle end of oven.
14.NOTE: When putting new shaft and blower wheels back in, the wheels will have to be removed from the shaft.
It is important to mark the blowers left and right and to mark the positioning of the blowers on the shaft so as to
maintain spacing and balance.
When replacing the burner tube, the top
of the holes in the burner tube should be
12 3/8" from the bottom of the oven.
15. When replacing the expansion bearing in
the drive end, be sure the yoke of the bearing
is pushed as far as possible towards the
oven wall and tightened on the shaft. This
will allow the bearing to expand outward.
Align pulley on drive end of shaft with
pulley on drive motor. Grease bearings
before starting oven.
Impinger X2 – Analog Service Manual – Dom & Int’l
17
RELAY, MAIN FAN, - REPLACEMENT
1.
2.
3.
4.
5.
6.
Shut off power at main breaker.
Remove control box cover.
Disconnect all wiring from relay and mark all wiring for reassembly.
Remove main relay and overload protector.
Remove overload protector from main relay and mount overload protector on new relay.
Reassemble in reverse order and check system for proper operation.
TIMER, 30 MINUTE COOL DOWN – REPLACEMENT
1.
2.
3.
4.
5.
Shut off power at main breaker.
Remove control box cover.
Disconnect all wiring from 30-minute cool down timer and mark all wires for reassembly.
Remove one mounting bolt and remove 30-minute cool down timer.
Reassemble in reverse order and check system operation.
FUSE HOLDER – REPLACEMENT
1.
2.
3.
4.
5.
Shut off power at main breaker.
Remove control box cover.
Disconnect wiring from fuse holder and mark all wiring for reassembly.
Remove mounting nut from fuse holder and remove fuse holder.
Reassemble in reverse order and check system operation.
SWITCH, ON/OFF – REPLACEMENT
1.
2.
3.
4.
Shut off power at main breaker.
Remove control box cover.
Disconnect wiring from switch and mark all wiring for reassembly.
Remove switch by loosening the mounting screw at the bottom of the switch and lifting the
release lever at the top of the switch. Lifting the release lever allows the front portion of the switch
to separate from the rear portion of the switch.
5.
Reassemble in reverse order and check system operation.
MOTOR, BURNER BLOWER – REPLACEMENT
1.
2.
3.
Shut off power at main breaker.
Remove control box cover and front control box cover.
Remove box cover from burner blower motor and disconnect wiring from motor. Mark all wiring
for reassembly.
4.
5.
Remove three mounting screws and remove burner blower motor assembly.
Remove box and components from the old burner blower motor and mount on new burner blower
motor. Mark all wiring for proper assembly. Remove air shutter assembly from old motor and
mount on new motor.
6.
Reassemble in reverse order and check system operation.
TRANSFORMER, BURNER – REPLACEMENT
1.
2.
3.
4.
5.
6.
Shut off power at main breaker.
Remove control box cover and front control box cover.
Remove box cover from burner blower motor.
Disconnect wiring from burner transformer and mark all wiring for reassembly.
Remove two mounting screws and remove burner transformer.
Reassemble in reverse order and check system operation.
RELAY, BURNER BLOWER – REPLACEMENT
1.
2.
3.
Shut off power at main breaker.
Remove control box cover and front control box cover.
Remove box cover from burner blower motor.
18
Impinger X2 – Analog Service Manual – Dom & Int’l
4.
5.
6.
Disconnect wiring from burner blower relay and mark all wiring for reassembly.
Remove two mounting screws and remove burner blower relay.
Reassemble in reverse order and check system operation.
BURNER CONTROL – REPLACEMENT
1.
2.
3.
4.
5.
Shut off power at main breaker.
Remove control box cover
Disconnect wiring from burner control and mark all wiring for reassembly.
Remove mounting screws and remove burner control.
Reassemble in reverse order and check system operation.
AIR PRESSURE SWITCH – REPLACEMENT
1.
2.
3.
Shut off power at main breaker.
Remove control box cover and rear control box cover.
Remove cover from air pressure switch. Disconnect wiring from air pressure switch and mark all
wiring for reassembly.
4.
Remove air switch tube from air pressure switch. Note location of air switch tube, tube must be
connected to the “HIGH” port of the air pressure switch.
Remove mounting screws and remove air pressure switch.
Reassemble in reverse order. Adjust air pressure switch for proper operation (see below) and
check system operation.
5.
6.
AIR PRESSURE SWITCH – ADJUSTMENT
1.
Start the oven. After the burner ignites, turn the air pressure switch adjustment screw Clockwise
until the burner shuts off.
2.
3.
4.
Turn the adjustment screw Counterclockwise until the burner ignites, plus one full turn.
Seal adjustment screw with nail polish.
Replace cover on air pressure switch.
ELECTRONIC TEMPERATURE CONTROL – REPLACEMENT
1.
2.
3.
4.
Shut off power at main breaker.
Remove control box cover.
Disconnect wiring from electronic temperature control and mark all wiring for reassembly.
Locate and remove mounting screw at the bottom center of the electronic temperature control.
Remove control from control base.
5.
6.
Remove two mounting screws from control base and remove control base from oven.
Reassemble in reverse order and check calibration of new control (see below) and check system
operation.
ELECTRONIC TEMPERATURE CONTROL – CALIBRATION
1.
2.
Turn burner switch off.
Remove electronic temperature control from the mounting base by removing one retaining screw
at the bottom of the electronic temperature control. Pull electronic temperature control from it’s
mounting base.
3.
4.
5.
Locate Hairpin switch on the control and open the Hairpin switch. (See photo, next page)
Replace control in the mounting base.
Turn the burner switch on. If the display reads “CAL”, press the “UP” arrow until the display reads
“Cnf” on the SV (orange) display.
Press the FUNC key until the display reads “P13” in the SV (orange) portion of the display. Using
the “UP” or “DOWN” arrows, adjust the “PV” (yellow) portion of the display to read 500. This is the
offset point.
Press the FUNC key until the display reads “P14” in the SV (orange) portion of the display. Using
the “UP” or “DOWN” arrows, adjust the “PV” (yellow) portion of the display to read –50. This is the
“offset value”. (continued next page)
6.
Impinger X2 – Analog Service Manual – Dom & Int’l
19
7.
8.
Press the “FUNC” key until the display reads “Cnf”. Shut off burner, remove control from the
mounting base. Close the Hairpin switch on the control and replace the control in the mounting
base.
Turn the burner on. Set oven temperature to 500°F and verify calibration. Allow oven to preheat
for at least 30 minutes. Place temperature probe in the center of the oven, on the top conveyor.
If the actual temperature differs from the displayed temperature more than 5°, the “offset value”
must be adjusted (steps 2 through 7), until the proper temperature is indicated on the display.
Reassemble in reverse order and check system operation.
9.
HAIRPIN SWITCH
THERMOCOUPLE – REPLACEMENT
1.
2.
3.
4.
Shut off power at main breaker.
Remove control box cover.
Disconnect thermocouple from electronic temperature control. Note wire colors for reassembly.
Remove oven back assy. Remove thermocouple from mounting flange in blower housing. Remove
thermocouple from oven.
5.
Reassemble in reverse order and check system operation.
THERMOSTAT, HI-LIMIT – REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
Shut off power at main breaker.
Remove control box cover.
Disconnect all wiring from hi-limit thermostat and mark all wiring for reassembly.
Remove oven back assy. Remove capillary tube from mounting bracket.
Remove mounting nut and remove hi-limit thermostat from oven.
Reassemble in reverse order and check system operation.
NOTE: Depress reset button to insure thermostat is set for operation.
TEMPERATURE REGULATION VALVE – REPLACEMENT
1.
2.
3.
4.
Shut off power at main breaker.
Shut off the gas supply to the oven and disconnect the flexible gas hose from the oven.
Remove control box cover.
Disconnect all wiring from the temperature regulation valve and the main gas valve. Mark all wiring for
reassembly.
Remove pilot tube from gas valve. Disconnect pipe union at the burner and at the inlet side of the main
gas valve. Loosen pipe clamp and remove valves and piping assembly.
Remove piping from old valve and reassemble in reverse order.
Check all gas line fittings for leaks and check system operation.
5.
6.
7.
GAS VALVE – REPLACEMENT
1.
2.
3.
Shut off power at main breaker.
Shut off the gas supply to the oven and disconnect the flexible gas hose from the oven.
Remove control box cover.
20
Impinger X2 – Analog Service Manual – Dom & Int’l
4.
5.
Disconnect all wiring from the temperature regulation valve and the main gas valve. Mark all wiring for
reassembly.
Remove pilot tube from gas valve. Disconnect pipe unions at the burner and at the inlet side of the main
gas valve. Loosen pipe clamp and remove valves and piping assembly.
Remove piping from old valve and reassemble in reverse order.
Check all gas line fittings for leaks and adjust manifold pressure on gas valve. Refer to the specification
plate on the oven for proper gas manifold pressure. Check system operation.
6.
7.
MAIN BURNER ORIFICE – REPLACEMENT
1.
2.
3.
4.
Shut off power at main breaker.
Shut off the gas supply to the oven and disconnect the flexible gas hose from the oven.
Remove control box cover and control box front cover.
Remove pilot tube from gas valve. Disconnect pipe union at burner, loosen pipe union at inlet to gas
valve, loosen pipe clamp and move piping away from burner.
Remove two mounting nuts from burner flange and remove burner flange.
Remove main burner orifice from the burner flange.
5.
6.
7.
8.
Reassemble in reverse order.
Check all gas line fittings for leaks and check system operation.
PILOT ORIFICE – REPLACEMENT
1.
2.
3.
4.
Shut off power at main breaker.
Shut off the gas supply to the oven and disconnect the flexible gas hose from the oven.
Remove control box cover and control box front cover.
Remove pilot tube from gas valve. Disconnect pipe union at burner and at inlet to main gas valve. Loosen
pipe clamp and move piping away from burner.
Disconnect wiring from burner and mark wiring for reassembly.
Remove four screws from burner end plate and remove burner assembly from burner housing.
Remove pilot tube from igniter assembly and remove pilot orifice.
Reassemble in reverse order. Check all gas line fittings for leaks. Check system operation.
5.
6.
7.
8.
SPARK IGNITER – REPLACEMENT
1.
2.
3.
4.
Shut off power at main breaker.
Shut off the gas supply to the oven and disconnect the flexible gas hose from the oven.
Remove control box cover and control box front cover.
Remove pilot tube from gas valve. Disconnect pipe union at burner and at inlet to main gas valve. Loosen
pipe clamp and move piping away from burner.
Disconnect wiring from burner and mark wiring for reassembly.
Remove four screws from burner end plate and remove burner assembly from burner housing.
Remove pilot tube, pilot shield and pilot orifice from spark igniter and remove spark igniter.
Reassemble in reverse order and check system operation.
5.
6.
7.
8.
CONVEYOR MOTOR – REPLACEMENT
1.
2.
3.
4.
5.
6.
Shut off power at main breaker.
Remove control box cover and front control box cover.
Disconnect wiring from the conveyor motor assembly and mark all wiring for reassembly.
Remove four screws and remove conveyor motor assembly.
Remove hall effect sensor and magnet (one mounting nut) and mounting stud from old motor.
Reassemble in reverse order and check system operation.
REVERSING SWITCH – REPLACEMENT
1.
2.
3.
4.
5.
Shut off power at main breaker.
Remove control box cover.
Disconnect wiring from reversing switch and mark all wiring for reassembly.
Remove mounting nut from reversing switch and remove reversing switch.
Reassemble in reverse order and check system operation.
Impinger X2 – Analog Service Manual – Dom & Int’l
21
HALL EFFECT SENSOR – REPLACEMENT
1.
2.
3.
4.
5.
Shut off power at main breaker.
Remove control box cover.
Disconnect all wiring from hall effect sensor and mark all wiring for reassembly.
Remove mounting nut and remove hall effect sensor and magnet.
Reassemble in reverse order and check system operation.
CONVEYOR CONTROL – REPLACEMENT
1.
2.
3.
Shut off power at main breaker.
Remove control box cover.
Remove top and rear covers from conveyor control. Disconnect all wiring from the conveyor control and
mark all wiring for reassembly.
4.
5.
Remove two screws and remove faceplate from conveyor control. Remove two mounting screws and
remove conveyor control.
Reassemble in reverse order, set control for proper programming (see CONVEYOR CONTROL -
PROGRAMMING) and check system operation.
22
Impinger X2 – Analog Service Manual – Dom & Int’l
CONVEYOR CONTROL – PROGRAMMING
1.
2.
Determine which brand of motor is connected to the conveyor control.
Determine which type of dart conveyor control is installed in the oven. Looking at the face of the control,
the old style control will have “up” and “down” keys only. The new style Dart conveyor control will have
“up”, “down” and “enter” keys.
3.
4.
Determine the type of drive, direct, 10/15 chain reduction or right angle drive.
Determine the bake chamber size, 40”, 62” or 70”.
“DART” Conveyor control with “UP” and “DOWN” keys only (OLD STYLE).
DIP switches
1.
2.
3.
4.
Remove control box cover.
Remove top cover from conveyor control. Make sure that all DIP switches are in the OFF position.
Turn oven on, turn conveyor on. Set switch #7 to ON position. Display should read “PROG”.
Set switch #4 to ON position to set time mode. Press “UP” or “DOWN” keys to set value at :05. Set
switch #4 to OFF, display should read “PROG” and a colon should be lit.
5.
Set switch #1 to ON position to set constant. Use the “UP” or “DOWN” keys to set the following:
CHAMBER
LENGTH
DRIVE
TYPE
CONSTANT
DAYTON
CONSTANT
GLEASON
AVERY 60Hz.
2:25
CONSTANT
GLEASON
AVERY 50Hz.
2:17
40”
62”
70”
Direct
10/15 chain reduction
Right angle motor
2:00
3:01
1:31
Direct
10/15 chain reduction
Right angle motor
3:07
4:40
2:22
3:45
4:14
3:33
Direct
10/15 chain reduction
Right angle motor
3:31
5:16
2:40
6.
7.
Set switch #1 to OFF position, display should read “PROG”.
Set switch #2 to ON position to set minimum setting. Use “UP” or “DOWN” keys to set to 2:15. Set switch
#2 to OFF position, display should read “PROG”.
Set switch #3 to ON position, to set maximum setting. Use “UP” or “DOWN” keys to set to 16:00. Set
switch #3 to OFF position, display should read ”PROG”.
Set switch #7 to OFF position. Programming is complete.
Reassemble in reverse order and check system operation.
8.
9.
10.
Impinger X2 – Analog Service Manual – Dom & Int’l
23
CONVEYOR CONTROL – PROGRAMMING – DAYTON MOTOR, DIRECT DRIVE
Jumper
“DART” Conveyor control with “UP”, “DOWN” and “ENTER” keys (NEW STYLE).
1.
2.
Remove control box cover.
Remove top cover from conveyor control. Locate program jumper on conveyor control and set jumper to
the “ON” position.
3.
4.
Turn oven on, turn conveyor on. Press and hold the “ENTER” key until the Parameter Selection Mode is
entered (display will indicate “P 0”).
Using the “UP” or “DOWN” keys, select the parameters to be changed (See chart below). When the
parameter is selected, press “ENTER”. Use the “UP” or “DOWN” keys to set the desired parameter.
Press “ENTER” to save the changes.
After all parameters are programmed, select parameter 0 and press the “ENTER” key to return to the
running mode.
5.
6.
7.
Set program jumper on conveyor control to “OFF”.
Reassemble in reverse order and check system operation.
Parameter
40” Oven
62” Oven
70” Oven
Explanation
Time Mode Setting (MM:SS)
10
20
21
30
31
32
50
53
98
2
135
960
135
1609
1
7
1
5
2
135
960
135
2494
1
7
1
5
2
135
960
135
2816
1
7
1
5
Display minimum setting (value is in seconds)
Display maximum setting (value is in seconds)
Display setting at reference RPM, parameter 31
RPM at which display reference, should be displayed
Pulses per revolution of shaft encoder or pickup
Activate alarm when pickup stalled
Alarm flash enabled
Save parameter settings to user default area
24
Impinger X2 – Analog Service Manual – Dom & Int’l
CONVEYOR CONTROL – PROGRAMMING – DAYTON MOTOR, RIGHT ANGLE DRIVE
Jumper
“DART” Conveyor control with “UP”, “DOWN” and “ENTER” keys.
8.
9.
Remove control box cover.
Remove top cover from conveyor control. Locate program jumper on conveyor control and set jumper to
the “ON” position.
10.
11.
Turn oven on, turn conveyor on. Press and hold the “ENTER” key until the Parameter Selection Mode is
entered (display will indicate “P 0”).
Using the “UP” or “DOWN” keys, select the parameters to be changed (See chart below). When the
parameter is selected, press “ENTER”. Use the “UP” or “DOWN” keys to set the desired parameter.
Press “ENTER” to save the changes.
After all parameters are programmed, select parameter 0 and press the “ENTER” key to return to the
running mode.
12.
13.
14.
Set program jumper on conveyor control to “OFF”.
Reassemble in reverse order and check system operation.
Parameter
62” Oven
Explanation
Time Mode Setting (MM:SS)
10
20
21
30
31
32
50
53
98
2
135
960
135
1894
1
7
1
5
Display minimum setting (value is in seconds)
Display maximum setting (value is in seconds)
Display setting at reference RPM, parameter 31
RPM at which display reference, should be displayed
Pulses per revolution of shaft encoder or pickup
Activate alarm when pickup stalled
Alarm flash enabled
Save parameter settings to user default area
Impinger X2 – Analog Service Manual – Dom & Int’l
25
CONVEYOR CONTROL – PROGRAMMING – GLEASON AVERY MOTOR, DIRECT DRIVE
Jumper
“DART” Conveyor control with “UP”, “DOWN” and “ENTER” keys.
15.
16.
Remove control box cover.
Remove top cover from conveyor control. Locate program jumper on conveyor control and set jumper to
the “ON” position.
17.
18.
Turn oven on, turn conveyor on. Press and hold the “ENTER” key until the Parameter Selection Mode is
entered (display will indicate “P 0”).
Using the “UP” or “DOWN” keys, select the parameters to be changed (See chart below). When the
parameter is selected, press “ENTER”. Use the “UP” or “DOWN” keys to set the desired parameter.
Press “ENTER” to save the changes.
After all parameters are programmed, select parameter 0 and press the “ENTER” key to return to the
running mode.
19.
20.
21.
Set program jumper on conveyor control to “OFF”.
Reassemble in reverse order and check system operation.
Parameter
40” Oven
62” Oven
70” Oven
Explanation
Time Mode Setting (MM:SS)
10
20
21
30
31
32
50
53
98
2
135
960
135
1933
1
7
1
5
2
135
960
135
2997
1
7
1
5
2
135
960
135
3383
1
7
1
5
Display minimum setting (value is in seconds)
Display maximum setting (value is in seconds)
Display setting at reference RPM, parameter 31
RPM at which display reference, should be displayed
Pulses per revolution of shaft encoder or pickup
Activate alarm when pickup stalled
Alarm flash enabled
Save parameter settings to user default area
26
Impinger X2 – Analog Service Manual – Dom & Int’l
This page intentionally left blank.
Impinger X2 – Analog Service Manual – Dom & Int’l
27
IMPINGER X2 OVENS
GENERAL VIEW
LETTER
PART NUMBER
DESCRIPTION
A
B
C
D
E
F
G
H
I
9004415
9004415
9004422
9004422
9004416
9004416
7007757
7007168
7007168
1111302010
1001303010
2001303020
7007378
7007378
300801140-1
100801140-1
200801140-1
300801140
100801140
200801140
2805112
100804622
100302900
100303900
300202036
100202036
200202036
9004447
9004443
9004417
9004448
9004434
9004418
100537902
9409
Finger housing, bottom (3240), #5 left (3262, 3270)
Finger housing, bottom (3240), #6 right (3262, 3270)
Finger housing, middle (3240), #3 left (3262, 3270)
Finger housing, middle (3240), #4 right (3262, 3270)
Finger housing, top, (3240), #1 left (3262, 3270)
Finger housing, top, (3240), #2 right (3262, 3270)
Finger cover, top
Finger cover, middle
Finger cover bottom
Air return, middle, upper model 3262, 3270
Air return, lower model 3262
Air return, lower model 3270
Finger guide assy. model 3240, 3262, 3270
Finger guide, rear
Door, solid - 3240
Door, solid – 3262
Door, solid – 3270
Door, w/window – 3240
Door, w/window – 3262
Door, w/window – 3270
Nameplate, Impinger X2
Sandwich door assy.
J
K
L
M
N
O
P
Q
Caster, 5”
Caster, 5” w/brake
R
S
T
Bottom finger support, 3240
Bottom finger support, 3262
Bottom finger support, 3270
Center finger support, 3240
Center finger support, 3262
Center finger support, 3270
Top finger support, 3240
Top finger support, 3262
Top finger support, 3270
Door latch assy.
Oven base, high – 3240
U
V
9414
9402
Oven base, low –3240
Oven base, high – 3262
9411
9404
Oven base, low – 3262
Oven base, high – 3270
9412
Oven base, low – 3270
Hinge plate, left
Hinge plate, right
Center air return, upper – 3262
Center air return, upper – 3270
Center air return, middle – 3263
Center air return, middle – 3270
Center air return, lower – 3262
Center air return, lower - 3270
W
X
Y
Z
108003-1EP
108003-2EP
9004439
9004436
9004440
9004437
9004441
9004438
28
Impinger X2 – Analog Service Manual – Dom & Int’l
Impinger X2 – Analog Service Manual – Dom & Int’l
29
IMPINGER X2 OVENS
OVEN CAVITY
LETTER
A
PART NUMBER
DESCRIPTION
Guard, shaft – 3262
Guard, shaft – 3270
9004435
9004419
B
C
4071215
Housing, blower
100601417
200601417
100601417
200601417
100601394
100110224
100102601
100106000
300601280
100601280
200601280
300601328
100601328
200601328
3001401011
1001401011
2001401011
100601334/100601336
100601324
390048
Air return plate, right – 3240, 3262
Air return plate, right – 3270
Air return plate, left – 3240, 3262
Air return plate, left – 3270
Air dam, upper
Close-off, upper plenum
Support, oven cavity
D
E
F
G
H
I
Plate, connector
Extension tube, burner – 3240
Extension tube, burner – 3262
Extension tube, burner – 3270
Shaft, blower wheel assy. – 3240
Shaft, blower wheel assy. – 3262
Shaft, blower wheel assy. – 3270
Oven back – 3240
Oven back – 3262
Oven back – 3270
Burner heat shield, outer, inner
Burner opening cover
Heat slinger – 3240
J
K
L
M
N
390047
390063
9004431
100120224
100110204
7007374
Heat slinger – 3262, 3270
Bearing, idler
Top cover, idler end
O
P
Q
R
S
Cover, idler end
Flange, thermocouple mount
Guard, center air return – 3262
Guard, center air return - 3270
7007375
30
Impinger X2 – Analog Service Manual – Dom & Int’l
Impinger X2 – Analog Service Manual – Dom & Int’l
31
IMPINGER X2 OVENS
CONTROL BOX
LETTER
PART NUMBER
DESCRIPTION
Coupling w/sleeve
Front cover –2 oven
Front cover – 2TS oven (split belt top)
Front cover – 2SB oven (split belt bottom)
Front cover –2SS oven (split belt top and bottom)
Conveyor drive motor
A
B
508120EP
100501329
100501327
100501326
100501325
501176MEP
501110EP
100507900/100507705
508202EP
390069
C
D
E
F
Hall effect sensor
Pulley, shaft/ Sheave, driver
V-belt, 3240, 3262, 3270 – 60Hz. (BK 52 x 7/8”)
V-belt, 3240, 3262, 3270 – 50Hz. (BK 45 x 7/8”)
Pulley, motor, 3240, 3262, 3270 – 60 Hz.
Pulley, motor, 3240, 3262, 3270 – 50 Hz.
Motor, main fan – 60 Hz. 1 phase
Motor, main fan – 60 Hz. 3 phase
Motor, main fan – 50 Hz. 1 phase
Air pressure switch
Air pressure switch (CE ovens)
Switch, conveyor reversing
Ignition control, 60 Hz. ovens
Ignition control, 50 Hz. ovens
Relay/overload, 3240
Relay/overload, 3262, 3270
Cool-down timer, 120VAC
Cool-down timer, 230VAC
Terminal block, 5-pole
Cover, rear
Cover, control box top
G
H
390070
390059
4060276
4060274
4060275
501070EP
369575
390075
501250-2EP
370396
390067
390068
601492EP
370466
4000214
100501232
9004432
369368
4090413
501201EP
4070599
I
J
K
L/M
N
O
P
Q
R
S
T
Thermostat, oven cavity hi-limit
Fuse holder, 6 position
Fuse, 2A
Fuse holder, 60 Hz. ovens
Fuse holder, CE ovens (50 Hz.)
Plug connector, diagnostic (part of wire harness)
Control, conveyor
U
370342
V
W
X
501100EP
390060
Switch, ON/OFF
Y
Z
AA
501085EP
501090EP
9004363
9004364
9004365
9004347
4071191
370180
Control, temperature
Thermocouple, type ”J”
Control panel, -2 oven
Control panel, -2SB oven (split belt bottom)
Control panel, -2TS oven (split belt top)
Control panel, -2SS oven (split belt top and bottom)
Strain relief
EMI Filter (Export only)
RFI Filter (Export only)
BB
Not shown
Not shown
370184
32
Impinger X2 – Analog Service Manual – Dom & Int’l
Impinger X2 – Analog Service Manual – Dom & Int’l
33
IMPINGER X2 OVENS
BURNER/DRIVE END
LETTER
PART NUMBER
DESCRIPTION
Flange, burner
Heat slinger, 3240
A
B
7007124
390048
390047
Heat slinger, 3262, 3270
Bearing, drive end
Motor, burner blower
Relay, time delay
Transformer, 120/24VAC
Flame target
Igniter/sensor assy.
C
D
E
F
G
H
I
507500EP
501260EP
501250-8EP
369531
369142
501250-1EP
100501271
Shield, pilot
J
K
Cable, spark
Orifice, pilot, Nat.
2605078
Orifice, pilot, L.P.
Manifold, burner
L
M
370059
369398
Valve, temperature regulation (120 VAC)
Valve, temperature regulation (CE ovens, 220VAC)
Valve, main gas (24VAC)
Valve, main gas (CE ovens, 220 VAC)
Orifice, main burner, Nat.
Orifice, Main burner, L.P.
Moveable plate, air shutter
Air shutter
370186
50150-5EP
370433
N
O
2605080
P
Q
369400
369399
34
Impinger X2 – Analog Service Manual – Dom & Int’l
Impinger X2 – Analog Service Manual – Dom & Int’l
35
IMPINGER X2 OVENS
CONVEYOR, SINGLE
LETTER
A
PART NUMBER
DESCRIPTION
Shelf, infeed side
Shelf, out take side
Pan stop, zero stop
Crumb pan (bottom conveyor only)
Connecting link
Conveyor belt - complete, 3240
Conveyor belt - complete, 3262
Conveyor belt - complete, 3270
Conveyor belt –1ft. section
Bushing assembly, single belt
Shaft, idle end
100403103
100403101
100403107
10040710
369005
100405831
100405810
100405830
405830-1EP
390051
100404710
406000EP
405900EP
300403331
100403361
200403390
300403330
100403360
200403380
508103EP
100404810
B
C
D
E
F
G
H
I
Roller, smooth
Roller, notched
J
Frame assembly, upper conveyor, 3240
Frame assembly, upper conveyor, 3262
Frame assembly, upper conveyor, 3270
Frame assembly, lower conveyor, 3240
Frame assembly, lower conveyor, 3262
Frame assembly, lower conveyor, 3270
Coupling half
K
L
Shaft, drive end
36
Impinger X2 – Analog Service Manual – Dom & Int’l
Impinger X2 – Analog Service Manual – Dom & Int’l
37
IMPINGER X2 OVENS
CONVEYOR, DUAL BELT
LETTER
A
PART NUMBER
DESCRIPTION
100403103
100403101
100403107
100403710
405849-2EP
100405847
405849EP
100405844
405849-1EP
390050
100404710
406000EP
405900EP
300403331
100403361
200403390
300403330
100403360
200403380
508103EP
100404810
Take off shelf, infeed side
Take off shelf, out take side
Pan stop, zero stop
Crumb pan (bottom conveyor only)
Connecting link
Conveyor belt, complete, 3240
Conveyor belt, complete, 3262
Conveyor belt, complete, 3270
Conveyor belt, 1ft. section
Bushing assembly, dual belt
Shaft, idle end
B
C
D
E
F
G
H
I
Roller, smooth
Roller, notched
J
Frame assembly, upper conveyor, 3240
Frame assembly, upper conveyor, 3262
Frame assembly, upper conveyor, 3270
Frame assembly, lower conveyor, 3240
Frame assembly, lower conveyor, 3262
Frame assembly, lower conveyor, 3270
Coupling half
K
L
Shaft, drive
38
Impinger X2 – Analog Service Manual – Dom & Int’l
Impinger X2 – Analog Service Manual – Dom & Int’l
39
40
Impinger X2 – Analog Service Manual – Dom & Int’l
|