		 Intel® Core™ 2 Duo Mobile   
					Processors on 45-nm process for   
					Embedded Applications   
					Thermal Design Guide   
					June 2008   
					Order Number: 320028-001   
				Core™ 2 Duo Mobile Processors—Contents   
					Contents   
					1.0 Introduction ............................................................................................................. 6   
					
					
					
					
					
					
					
					
					2.0 Package Information ................................................................................................ 9   
					3.0 Thermal Specifications.............................................................................................10   
					
					
					
					
					4.0 Mechanical Specifications ........................................................................................11   
					
					
					4.1.1 Die Pressure/Load Upper Limit..................................................................11   
					4.1.2 Die Pressure/Load Lower Limit..................................................................11   
					
					
					
					
					5.0 Thermal Solution Requirements...............................................................................15   
					
					
					® 
					
					
					6.0 Reference Thermal Solutions ...................................................................................18   
					
					
					
					
					
					Keep Out Zone Requirements..............................................................................19   
					Thermal Performance.........................................................................................19   
					1U+ Reference Heatsink.....................................................................................19   
					6.4.1 Keep Out Zone Requirements...................................................................20   
					6.4.2 Thermal Performance..............................................................................20   
					
					6.5.1 Keep Out Zone Requirements...................................................................22   
					6.5.2 Thermal Performance..............................................................................22   
					Heatsink Fastener Assembly................................................................................22   
					
					
					
					
					
					
					7.0 Thermal Metrology...................................................................................................24   
					
					
					
					
					
					
					Additional Thermal Features................................................................................24   
					
					7.4.1 Active Heatsink Measurements .................................................................25   
					7.4.2 Passive Heatsink Measurements................................................................25   
					8.0 Reliability Guidelines ...............................................................................................28   
					
					
					Thermal Solution Component Suppliers....................................................................29   
					Mechanical Drawings ...............................................................................................30   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					3 
					June 2008   
					Order Number: 320028-001   
				Figures—Core™ 2 Duo Mobile Processors   
					Figures   
					
					
					
					
					
					
					
					
					
					Thermal Design Process..............................................................................................7   
					Primary Side Keep Out Zone Requirements— Micro-FCPGA ............................................ 12   
					
					Secondary Side Keep Out Zone Requirements.............................................................. 14   
					
					
					
					
					
					10 CompactPCI Reference Heatsink Assembly .................................................................. 21   
					11 cPCI Reference Heatsink Thermal Performance vs. Volumetric Flow Rate ......................... 22   
					12 Heatsink Orientation Relative to Airflow Direction ......................................................... 23   
					13 Measuring TLA with an Active Heatsink ....................................................................... 26   
					14 Measuring TLA with a Passive Heatsink ....................................................................... 27   
					
					
					17 AdvancedTCA* Reference Heatsink Assembly............................................................... 33   
					18 AdvancedTCA* Reference Heatsink............................................................................. 34   
					
					
					21 CompactPCI* Reference Heatsink Assembly................................................................. 37   
					22 CompactPCI* Reference Heatsink............................................................................... 38   
					23 1U Reference Heatsink PCB Keep Out Requirements (Sheet 1 of 2)................................. 39   
					24 1U Reference Heatsink PCB Keep Out Requirements (Sheet 2 of 2)................................. 40   
					25 1U Reference Heatsink Assembly ............................................................................... 41   
					26 1U Reference Heatsink.............................................................................................. 42   
					Tables   
					
					
					
					
					
					
					Definition of Terms.....................................................................................................7   
					® 
					Thermal Specifications for the Intel Core™2 Duo processor.......................................... 10   
					Required Heatsink Thermal Performance (Ψ )............................................................. 17   
					
					
					
					
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					TDG   
					June 2008   
					Order Number: 320028-001   
					4 
				Core™ 2 Duo Mobile Processors—Tables   
					Revision History   
					Date   
					Revision   
					Description   
					June 2008   
					1.0   
					First Public release.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					5 
					June 2008   
					Order Number: 320028-001   
				Introduction—Core™ 2 Duo Mobile Processors   
					1.0   
					Introduction   
					The power dissipation of electronic components has risen along with the increase in complexity of   
					computer systems. To ensure quality, reliability, and performance goals are met over the product’s life   
					cycle, the heat generated by the device must be properly dissipated. Typical methods to improve heat   
					dissipation include selective use of airflow ducting, and/or the use of heatsinks.   
					The goals of this document are to:   
					• Identify the thermal and mechanical specification for the device.   
					• Describe a reference thermal solution that meets the specifications.   
					A properly designed thermal solution will adequately cool the device at or below the thermal   
					specification. This is accomplished by providing a suitable local-ambient temperature, ensuring   
					adequate local airflow, and minimizing the die to local-ambient thermal resistance. Operation outside   
					the functional limits can degrade system performance and may cause permanent changes in the   
					operating characteristics of the component.   
					This document describes thermal design guidelines for the Intel® Core™ 2 Duo Mobile Processors on   
					45-nm process for Embedded Applications in the micro Flip Chip Pin Grid Array (micro-FCPGA)   
					package and the micro Flip Chip Ball Grid Array (micro-FCBGA) package. The information provided in   
					this document is for reference only and additional validation must be performed prior to implementing   
					the designs into final production. The intent of this document is to assist each original equipment   
					manufacturer (OEM) with the development of thermal solutions for their individual designs. The final   
					heatsink solution, including the heatsink, attachment method, and thermal interface material (TIM)   
					must comply with the mechanical design, environmental, and reliability requirements delineated in   
					the processor datasheet. It is the responsibility of each OEM to validate the thermal solution design   
					with their specific applications.   
					This document addresses thermal and mechanical design specifications for the Intel Core 2 Duo   
					processor only. For thermal design information on other Intel components, refer to the respective   
					component datasheets.   
					1.1   
					Design Flow   
					Several tools are available from Intel to assist with the development of a reliable, cost-effective   
					thermal solution. Figure 1 illustrates a typical thermal solution design process with available tools   
					noted. The tools are available through your local Intel field sales representative.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					6 
					 
					 
				Core™ 2 Duo Mobile Processors—Introduction   
					Figure 1.   
					Thermal Design Process   
					Step 1: Thermal Simulation   
					• Package Level Thermal Models   
					Step 2: Heatsink Design   
					and Selection   
					• Thermal Model User’s Guide   
					• Reference Heatsinks   
					• Reference Mounting Hardware   
					• Vendor Contacts   
					Step 3: Thermal Validation   
					• Thermal Testing Software   
					• Thermal Test Vehicle   
					• User Guides   
					1.2   
					Definition of Terms   
					Table 1.   
					Definition of Terms (Sheet 1 of 2)   
					Term   
					Definition   
					Flip Chip Pin Grid Array. A pin grid array packaging technology where the die is   
					exposed on the package substrate.   
					FCPGA   
					FCBGA   
					Flip Chip Ball Grid Array. A ball grid array packaging technology where the die is   
					exposed on the package substrate.   
					T 
					Maximum allowed component (junction) temperature. Also referred to as T   
					J-MAX   
					JUNCTION-MAX   
					Thermal Design Power. Thermal solutions should be designed to dissipate this   
					target power level.   
					TDP   
					Local ambient temperature. This is the temperature measured inside the chassis,   
					T 
					LA   
					approximately 1 inch upstream of a component heatsink. Also referred to as T .   
					A 
					Junction-to-ambient thermal characterization parameter. A measure of heatsink   
					Ψ 
					thermal performance using the total package power. Defined as (T   
					Total Package Power   
					– T ) /   
					JA   
					JUNCTION LA   
					Thermal interface material thermal characterization parameter. A measure of   
					thermal interface material performance using total package power. Defined as (T   
					Ψ 
					TIM   
					– T   
					)/ Total Package Power. Also referred to as Ψ   
					CASE   
					JUNCTION   
					JS.   
					Sink-to-ambient thermal characterization parameter. A measure of heatsink   
					Ψ 
					thermal performance using total package power. Defined as (T   
					Total Package Power.   
					– T   
					)/   
					SA   
					SINK   
					JUNCTION   
					°C   
					Degrees in Celsius   
					CFM   
					in.   
					Volumetric airflow rate in cubic feet per minute   
					Inches   
					LFM   
					PCB   
					Airflow velocity in linear feet per minute   
					Printed circuit board   
					T 
					Heatsink temperature measured on the underside of the heatsink base.   
					SINK   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					7 
					June 2008   
					Order Number: 320028-001   
					 
					 
					 
				Introduction—Core™ 2 Duo Mobile Processors   
					Table 1.   
					Definition of Terms (Sheet 2 of 2)   
					Term   
					Definition   
					Thermal Interface Material – the thermally conductive compound between the   
					heatsink and die. This material fills air gaps and voids, and enhances spreading of   
					the heat from the die to the heatsink.   
					TIM   
					A unit of measure used to define server rack spacing height. 1U is equal to 1.75   
					inches, 2U equals 3.50 inches, etc.   
					U 
					W 
					Watt   
					1.3   
					Reference Documents   
					The reader of this specification should also be familiar with material and concepts presented in the   
					following documents:   
					• Intel® Core™2 Duo Processor for Intel® Centrino® Duo Mobile Technology Datasheet   
					Documents are located at developer.intel.com. Contact your Intel field sales representative for   
					additional information.   
					1.4   
					Thermal Design Tool Availability   
					Intel provides thermal simulation models of the device and a thermal model user’s guide to aid   
					system designers in simulating, analyzing, and optimizing thermal solutions in an integrated, system-   
					level environment. The models are for use with commercially available Computational Fluid Dynamics   
					(CFD)-based thermal analysis tools including Flotherm* (version 7.1 or higher) by Flomerics, Inc. or   
					Icepak* by Fluent, Inc. Contact your Intel representative to order the thermal models and associated   
					user’s guides.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					8 
					 
					 
				Core™ 2 Duo Mobile Processors—Package Information   
					2.0   
					Package Information   
					The Intel® Core™2 Duo Processor (XE and SV) is available in 478-pin Micro-FCPGA packages as well   
					as 479-ball Micro-FCBGA packages. The Intel® Core™2 Duo Processor SFF processor (LV and ULV) is   
					available in 956-ball Micro-FCBGA packages. The package mechanical dimensions can be found in the   
					product’s datasheet.   
					The Micro-FCBGA package incorporates land-side capacitors. The land-side capacitors are electrically   
					conductive. Care should be taken to prevent the capacitors from contacting any other electrically   
					conductive materials. Doing so may short the capacitors and possibly damage the device or render it   
					inactive.   
					The processor package has mechanical load limits that are specified in the processor datasheet. These   
					load limits should not be exceeded during heatsink installation, removal, mechanical stress testing, or   
					standard shipping conditions. The heatsink mass can also add additional dynamic compressive load to   
					the package during a mechanical shock event. Amplification factors due to the impact force during   
					shock must be taken into account in dynamic load calculations. The total combination of dynamic and   
					static compressive load should not then exceed the processor datasheet compressive dynamic load   
					specification during a vertical shock. It is not recommended to use any portion of the processor   
					substrate as a mechanical reference or load bearing surface in either static or dynamic compressive   
					load conditions.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					9 
					June 2008   
					Order Number: 320028-001   
					 
				Thermal Specifications—Core™ 2 Duo Mobile Processors   
					3.0   
					Thermal Specifications   
					3.1   
					Thermal Design Power   
					
					FCBGA, micro-FCPGA package and socket via the base board is negligible. The cooling capacity   
					without a thermal solution is also minimal, so Intel requires the use of a heatsink for all usage   
					conditions.   
					3.2   
					Maximum Allowed Component Temperature   
					
					thermal solution is required to meet the temperatures specification while dissipating the Thermal   
					Design Power.   
					® 
					Table 2.   
					Thermal Specifications for the Intel Core™2 Duo processor   
					T 
					T 
					J-MIN   
					(°C)   
					J-MAX   
					CPU   
					Processor SKU#   
					TDP (W)   
					(°C)   
					Standard Voltage (Core 2 Duo-6M, Celeron-2M)   
					Low Voltage (Core 2 Duo -3M)   
					35   
					17   
					10   
					Intel® Core™ 2 Duo   
					Mobile Processors   
					on 45-nm process   
					105   
					0 
					Ultra Low Voltage (Core 2 Duo -2M, Celeron)   
					= 
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					10   
					 
					 
					 
					 
				Core™ 2 Duo Mobile Processors—Mechanical Specifications   
					4.0   
					Mechanical Specifications   
					4.1   
					Package Mechanical Requirements   
					Die Pressure/Load Upper Limit   
					4.1.1   
					From a die mechanical integrity standpoint, the maximum allowable normal die load is the lesser of   
					2 
					2 
					15 lbs or 100 psi. Considering the 15 lbs load limit and the nominal die area of 1.45 cm (0.22 in. ),   
					this equates to a die pressure of 66.7 psi (below 100 psi specification). Considering the maximum   
					pressure specification, the die load at this pressure would be 22.4 lbs, exceeding the 15 lbs. load   
					limit. Thus, the heatsink clamping mechanism (spring loaded fasteners, spring clips, etc.) should not   
					exceed 15 lbs.   
					4.1.2   
					Die Pressure/Load Lower Limit   
					From a TIM performance standpoint, a minimum die pressure is required to ensure consistent and   
					minimal TIM thermal resistance. This lower value is a function of the TIM used. For the phase-change   
					TIM specified for thermal solutions mentioned later, die pressure should not be lower than   
					approximately 138 kPa (20 psi). This will keep TIM resistance better than approximately   
					o 
					2 
					0.30 C-cm /W.   
					4.2   
					Package Keep Out Zones Requirements   
					
					should include a means to prevent the heatsink from forming an electrical short with the capacitors   
					placed on the top side of the package. The reference thermal solutions include z-stops machined into   
					the base of the heatsink. The z-stops prevent the heatsink from inadvertently tilting when installed.   
					Other methods are suitable including using electrically insulated gasket material at the base of the   
					heatsink.   
					4.3   
					Board Level Keep Out Zone Requirements   
					A general description of the keep-out zones and mounting hole pattern for the reference thermal   
					
					
					Components placed between the underside of the heatsink and motherboard cannot exceed 4.75 mm   
					
					micro-FCPGA package.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					11   
					June 2008   
					Order Number: 320028-001   
					 
					 
					 
					 
					 
					 
				Core™ 2 Duo Mobile Processors—Thermal Solution Requirements   
					5.0   
					Thermal Solution Requirements   
					5.1   
					Thermal Solution Characterization   
					The thermal characterization parameter, Ψ (“psi”), is used to characterize thermal solution   
					performance, as well as compare thermal solutions in identical situations (i.e., heating source, local   
					ambient conditions, etc.). It is defined by the following equation:   
					Equation 1. Junction-to-Local Ambient Thermal Characterization Parameter (Ψ )   
					JA   
					TJ −TA   
					ΨJA =   
					TDP   
					Ψ 
					= Junction-to-local ambient thermal characterization parameter (°C/W)   
					JA   
					T 
					= Maximum allowed device temperature (°C)   
					JUNCTION MAX   
					
					A 
					measurement guidelines)   
					TDP = Thermal Design Power (W)   
					The thermal characterization parameter assumes that all package power dissipation is through the   
					thermal solution (heatsink), and is equal to TDP. A small percentage of the die power (< 5%) is   
					dissipated through the package/socket/motherboard stack to the environment, and should not be   
					considered to be a means of thermal control.   
					The junction-to-local ambient thermal characterization parameter, Ψ , is comprised of Ψ , which   
					JA   
					JS   
					includes the thermal interface material thermal characterization parameter, and of Ψ , the sink-to-   
					SA   
					local ambient thermal characterization parameter:   
					Equation 2. Junction-to-Local Ambient Thermal Characterization Parameter   
					ΨJA = ΨJS + ΨSA   
					Where:   
					Ψ 
					= Thermal characterization parameter from junction-to-sink, this also includes thermal resistance   
					JS   
					of the thermal interface material (Ψ ) (°C/W).   
					TIM   
					Ψ 
					= Thermal characterization parameter from sink-to-local ambient (°C/W)   
					SA   
					Ψ 
					is a measure of the thermal characterization parameter from the bottom of the heatsink to the   
					SA   
					local ambient air. Ψ is dependent on the heatsink material, thermal conductivity, and geometry. It is   
					SA   
					also strongly dependent on the air velocity through the fins of the heatsink. Figure 5 illustrates the   
					combination of the different thermal characterization parameters.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					15   
					June 2008   
					Order Number: 320028-001   
					 
					 
					 
				Thermal Solution Requirements—Core™ 2 Duo Mobile Processors   
					Figure 5.   
					Processor Thermal Characterization Parameter Relationships   
					TA   
					ΨSA   
					HEATSINK   
					Ψ 
					JA   
					TIM   
					TS   
					TJ   
					Ψ 
					TIM   
					Device   
					5.1.1   
					Calculating the Required Thermal Performance for the Intel®   
					Core™2 Duo processor   
					Overall thermal performance, Ψ   
					is then defined using the thermal characterization parameter:   
					JA,   
					• Define a target component temperature T   
					and corresponding TDP.   
					JUNCTION   
					• Define a target local ambient temperature, T .   
					A 
					The following provides an illustration of how to determine the appropriate performance targets.   
					Assume:   
					• TDP = 35 W and T   
					= 105 °C   
					JUNCTION   
					• Local processor ambient temperature, T = 40 °C.   
					A 
					Using Equation 1, the maximum allowable resistance, junction-to-ambient, is calculated as:   
					Equation 3. Maximum Allowable Resistance   
					TJ −TA   
					TDP   
					105−40   
					ΨJA =   
					= 
					=1.857 o C /W   
					35   
					To determine the required heatsink performance, a heatsink solution provider would need to   
					determine Ψ performance for the selected TIM and mechanical load configuration. If the heatsink   
					CA   
					solution were designed to work with a TIM material performing at Ψ   
					≤ 0.50 °C/W, solving from   
					TIM   
					Equation 2, the performance of the heatsink required is:   
					Equation 4. Required Performance of the Heatsink   
					o 
					ΨSA = ΨJA − ΨJS =1.86− 0.50 =1.36 C /W   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					16   
					 
					 
				Core™ 2 Duo Mobile Processors—Thermal Solution Requirements   
					It is evident from the above calculations that a reduction in the local ambient temperature can have a   
					significant effect on the junction-to-ambient thermal resistance requirement. This effect can   
					contribute to a more reasonable thermal solution including reduced cost, heatsink size, heatsink   
					weight, or a lower system airflow rate.   
					
					Processors on 45-nm process. Since the data is based on air data at sea level, a correction factor   
					would be required to estimate the thermal performance at other altitudes.   
					Table 3.   
					Required Heatsink Thermal Performance (Ψ )   
					JA   
					TDP   
					(W)   
					Ψ 
					(ºC/W)   
					Ψ 
					(ºC/W)   
					JA   
					A 
					JA   
					A 
					CPU   
					Processor SKU   
					at T = 40 ºC   
					at T = 55 ºC   
					Standard Voltage   
					(Core 2 Duo-6M,   
					Celeron-2M)   
					35   
					17   
					1.86   
					3.82   
					1.42   
					2.94   
					Low Voltage   
					(Core 2 Duo -3M)   
					Intel® Core™ 2 Duo   
					Mobile Processors on 45-   
					nm process   
					Ultra Low Voltage   
					(Core 2 Duo -2M,   
					Celeron)   
					10   
					6.5   
					5.0   
					Notes:   
					1.   
					T is defined as the local (internal) ambient temperature measured approximately 1 inch upstream   
					A 
					from the device.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					17   
					June 2008   
					Order Number: 320028-001   
					 
				Reference Thermal Solutions—Core™ 2 Duo Mobile Processors   
					6.0   
					Reference Thermal Solutions   
					Intel has developed reference thermal solutions designed to meet the cooling needs of embedded   
					form factor applications. This chapter describes the overall requirements for the reference thermal   
					solution including critical-to-function dimensions, operating environment, and verification criteria.   
					This document details solutions that are compatible with the AdvancedTCA* and Server System   
					Infrastructure (1U and larger) form factors.   
					The data in this section is based on wind tunnel testing of the reference thermal solutions. The   
					heatsinks were tested as an assembly with a thermal test vehicle (TTV), TIM, socket and test board.   
					The test assembly is placed in a rectangular duct with no upstream obstructions. Air flow is measured   
					by means of a calibrated nozzle downstream of the unit under test. The Ψ values shown in the charts   
					to follow represent the mean resistance values plus the one-sided, 99 percent confidence interval.   
					6.1   
					ATCA Reference Thermal Solution   
					
					for this form factor is 21.33 mm, so the maximum heatsink height is constrained to 16.27 mm. The   
					heatsink uses the fastener assembly to mount to the PCB as described in Section 6.6, “Heatsink   
					
					
					Figure 6.   
					AdvancedTCA* Reference Heatsink Assembly   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					18   
					 
					 
					 
				Core™ 2 Duo Mobile Processors—Reference Thermal Solutions   
					6.2   
					Keep Out Zone Requirements   
					The keep out zone requirements on the PCB to use this heatsink are detailed in Appendix B,   
					“Mechanical Drawings”. Because it extends beyond the footprint of the device, it is critical for the   
					board designer to allocate space on the board for the heatsink.   
					6.3   
					Thermal Performance   
					The AdvancedTCA reference heatsink is an all copper (C1100) design. The performance of this   
					heatsink has been tested at flow rates from 10 CFM to 30 CFM. The heatsink is expected to meet the   
					thermal performance needed when the air flow rate is at least 10 CFM at 40 °C. For an external   
					ambient of 55°C (ψ = 1.32 °C/W), this heatsink is expected to be suitable for air flow rates around   
					ja   
					15 CFM.   
					Figure 7.   
					AdvancedTCA* Heatsink Thermal Performance vs. Volumetric Airflow Rate   
					6.4   
					1U+ Reference Heatsink   
					
					
					
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					19   
					June 2008   
					Order Number: 320028-001   
					 
					 
					 
					 
				Reference Thermal Solutions—Core™ 2 Duo Mobile Processors   
					Figure 8.   
					1U Reference Heatsink Assembly   
					6.4.1   
					Keep Out Zone Requirements   
					The keep out zone requirements on the PCB to use this heatsink are detailed in Appendix B,   
					“Mechanical Drawings”. Because it extends beyond the footprint of the device, it is critical for board   
					designers to allocate space for the heatsink.   
					6.4.2   
					Thermal Performance   
					The 1U reference heatsink employs a thick copper (C1100) base with aluminum (Al 1050) stamped   
					fins, soldered to the base. The heatsink has been tested at flow rates from 10 CFM to 25 CFM. For a   
					40 °C external ambient and 35 W TDP, the heatsink is expected to meet the thermal performance   
					needed when the air flow rate is greater than 10 CFM. If the external ambient is 55 °C, this heatsink   
					will be suitable if the air flow rate is approximately 12 CFM or greater.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					20   
					 
					 
					 
				Core™ 2 Duo Mobile Processors—Reference Thermal Solutions   
					Figure 9.   
					1U Heatsink Thermal Performance vs. Volumetric Airflow Rate   
					1U+ Reference Heatsink Performance   
					1.6   
					1.4   
					1.2   
					1 
					0.8   
					0.6   
					0.4   
					0.2   
					0 
					Psi_ja   
					Psi_sa   
					0 
					5 
					10   
					15   
					20   
					25   
					30   
					Volumetric Air Flow Rate (CFM)   
					6.5   
					Compact PCI Reference Heatsink   
					
					
					
					Figure 10.   
					CompactPCI Reference Heatsink Assembly   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					21   
					June 2008   
					Order Number: 320028-001   
					 
					 
					 
				Reference Thermal Solutions—Core™ 2 Duo Mobile Processors   
					6.5.1   
					Keep Out Zone Requirements   
					The keep out zone requirements on the PCB to use this heatsink are detailed in Appendix B,   
					“Mechanical Drawings.” Because it extends beyond the footprint of the device, it is critical for board   
					designers to allocate space for the heatsink.   
					6.5.2   
					Thermal Performance   
					The cPCI reference heatsink is an all copper (C1100) design, intended for applications where vertical   
					space is limited. The heatsink has been tested at flow rates from 4 CFM to 24 CFM. For a 40 °C   
					external ambient and 17W TDP, the heatsink is expected to meet the thermal performance needed   
					when the air flow rate is at least 4 CFM.   
					Figure 11.   
					cPCI Reference Heatsink Thermal Performance vs. Volumetric Flow Rate   
					6.6   
					Heatsink Fastener Assembly   
					The reference solutions use a screw, spring, and back plate assembly to attach the heatsink to the   
					PCB. The fastener assembly used on the reference heatsink must apply the load conditions described   
					
					the keep out zone requirements described in this document, and should not degrade the thermal   
					performance of the reference heatsinks. Finally the fastener assembly should be designed to meet the   
					
					6.7   
					Thermal Interface Material (TIM)   
					The thermal interface material provides improved conductivity between the die and heatsink. It is   
					important to understand and consider the impact of the interface between the die and heatsink base   
					to the overall thermal solution. Specifically, the bond line thickness, interface material area, and   
					interface material thermal conductivity must be selected to optimize the thermal solution.   
					It is important to minimize the thickness of the thermal interface material (TIM), commonly referred   
					to as the bond line thickness. A large gap between the heatsink base and the die yields a greater   
					thermal resistance. The thickness of the gap is determined by the flatness of both the heatsink base   
					and the die, plus the thickness of the thermal interface material, and the clamping force applied by   
					the heatsink attachment method. To ensure proper and consistent thermal performance, the TIM and   
					application process must be properly designed.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					22   
					 
					 
					 
					 
					 
				Core™ 2 Duo Mobile Processors—Reference Thermal Solutions   
					Thermal interface materials have thermal impedance (resistance) that will increase as the material   
					degrades over time. It is important for thermal solution designers to take this increase in impedance   
					into consideration when designing a thermal solution. It is recommended that system integrators   
					work with TIM suppliers to determine the performance of the desired thermal interface material. If   
					system integrators wish to maintain maximum thermal solution performance, the TIM could be   
					replaced during standard maintenance cycles.   
					The reference thermal solution uses Shin Etsu* G751. Alternative materials can be used at the user’s   
					discretion. Regardless, the entire heatsink assembly, including the heatsink, and TIM (including attach   
					method), must be validated together for specific applications.   
					6.8   
					Heatsink Orientation   
					All of the heatsinks were designed to maximize the available space within the volumetric keep out   
					zone and their respective form factor limitations. These heatsinks must be oriented in a specific   
					direction relative to the processor keep out zone and airflow. In order to use these designs, the   
					processor must be placed on the PCB in an orientation so the heatsink fins will be parallel to the   
					
					Figure 12.   
					Heatsink Orientation Relative to Airflow Direction   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					23   
					June 2008   
					Order Number: 320028-001   
					 
					 
				Thermal Metrology—Core™ 2 Duo Mobile Processors   
					7.0   
					Thermal Metrology   
					The system designer must make temperature measurements to accurately determine the   
					performance of the thermal solution. Validation of the processor’s thermal solution should be done   
					using a thermal test vehicle (TTV). The TTV allows for an accurate junction temperature measurement   
					as well as input power control. For more information, contact your Intel field sales representative.   
					In addition, the processor’s heatsink should be verified in a system environment. Intel has established   
					
					Measurements” provides guidelines on how to accurately measure the component temperature.   
					
					that will emulate anticipated maximum thermal design power.   
					7.1   
					Die Temperature Measurements   
					The component T   
					must be maintained at or below the maximum temperature specification as   
					JUNCTION   
					
					temperature is to use the Digital Thermal Sensor as described in the processor’s datasheet. Refer to   
					the processor datasheet for more information on the DTS.   
					The legacy on-board thermal diode is not recommended for performing heatsink validation. The   
					thermal diode is suitable for long term trending data, but is not a reliable indicator of the processor’s   
					temperature.   
					7.2   
					Power Simulation Software   
					The power simulation software is a utility designed to dissipate the thermal design power on a   
					processor. To assess the thermal performance of the processor thermal solution under “worst-case   
					realistic application” conditions, Intel is developing a software utility that operates the processor at   
					near worst-case power dissipation.   
					The power simulation software should only be used to test customer thermal solutions at or near the   
					thermal design power. For power supply current, please refer to each component’s datasheet for the   
					I 
					(Max Power Supply Current) specification. For information on how to obtain the maximum power   
					CC   
					program, contact your Intel field sales representative.   
					7.3   
					Additional Thermal Features   
					® 
					The Intel Core 2 Duo processor supports other thermal features including the Intel Thermal Monitor,   
					PROCHOT#, FORCEPR#, and THERMTRIP# signal pins. Details for using these features are contained   
					in the processor datasheet.   
					7.4   
					Local Ambient Temperature Measurement Guidelines   
					The local ambient temperature (T ) is the temperature of the ambient air surrounding the processor.   
					LA   
					For a passive heatsink, T is defined as the heatsink approach air temperature; for an actively cooled   
					A 
					heatsink, it is the temperature of inlet air to the active cooling fan.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					24   
					 
					 
					 
					 
					 
				Core™ 2 Duo Mobile Processors—Thermal Metrology   
					It is worthwhile to determine the local ambient temperature in the chassis around the processor to   
					understand the effect it may have on the case temperature. T is best measured by averaging   
					LA   
					temperature measurements at multiple locations in the heatsink inlet airflow. This method helps   
					reduce error and eliminate minor spatial variations in temperature. The following guidelines are   
					meant to enable accurate determination of the localized air temperature around the processor during   
					system thermal testing.   
					7.4.1   
					Active Heatsink Measurements   
					• It is important to avoid taking measurements in the dead flow zone that usually develops above   
					the fan hub and hub spokes. Measurements should be taken at four different locations uniformly   
					placed at the center of the annulus formed by the fan hub and the fan housing to evaluate the   
					uniformity of the air temperature at the fan inlet. The thermocouples should be placed   
					approximately 3 mm to 8 mm [0.1 to 0.3 in.] above the fan hub vertically and halfway between   
					
					• Using an open bench to characterize an active heatsink can be useful, and usually ensures more   
					uniform temperatures at the fan inlet. However, additional tests that include a solid barrier above   
					the test motherboard surface can help evaluate the potential impact of the chassis. This barrier is   
					typically clear Plexiglas*, extending at least 100 mm [4 in.] in all directions beyond the edge of   
					the thermal solution. Typical distance from the motherboard to the barrier is 81 mm [3.2 in.]. If a   
					barrier is used, the thermocouple can be taped directly to the barrier with clear tape at the   
					horizontal location as previously described, halfway between the fan hub and the fan housing.   
					• For even more realistic airflow, the motherboard should be populated with significant elements   
					like memory cards, graphic card, and chipset heatsink. If a variable speed fan is used, it may be   
					useful to add a thermocouple taped to the barrier above the location of the temperature sensor   
					used by the fan to check its speed setting against air temperature. When measuring T in a   
					LA   
					chassis with a live motherboard, add-in cards, and other system components, it is likely that the   
					T 
					measurements will reveal a highly non-uniform temperature distribution across the inlet fan   
					LA   
					section.   
					Note:   
					Testing an active heatsink with a variable speed fan can be done in a thermal chamber   
					to capture the worst-case thermal environment scenarios. Otherwise, when doing a   
					bench top test at room temperature, the fan regulation prevents the heatsink from   
					operating at its maximum capability. To characterize the heatsink capability in the   
					worst-case environment in these conditions, it is then necessary to disable the fan   
					regulation and power the fan directly, based on guidance from the fan supplier.   
					7.4.2   
					Passive Heatsink Measurements   
					• Thermocouples should be placed approximately 13 mm to 25 mm [0.5 to 1.0 in.] away from   
					
					• The thermocouples should be placed approximately 51 mm [2.0 in.] above the baseboard. This   
					placement guideline is meant to minimize the effect of localized hot spots from baseboard   
					components. The height above the board may vary depending on the height of the thermal   
					solution and form factor.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					25   
					June 2008   
					Order Number: 320028-001   
					 
					 
				Reliability Guidelines—Core™ 2 Duo Mobile Processors   
					8.0   
					Reliability Guidelines   
					Each motherboard, heatsink, and attach combination may vary the mechanical loading of the   
					component. The user should carefully evaluate the reliability of the completed assembly prior to use   
					
					Table 4.   
					Reliability Requirements   
					1 
					2 
					Test   
					Requirement   
					Pass/Fail Criteria   
					Visual Check and Electrical   
					Functional Test   
					Mechanical Shock   
					Random Vibration   
					Temperature Life   
					50 g, board level, 11 msec, 3 shocks/axis   
					Visual Check and Electrical   
					Functional Test   
					7.3 g, board level, 45 min/axis, 50 Hz to 2000 Hz   
					85 °C, 2000 hours total, checkpoints at 168, 500,   
					1000, and 2000 hours   
					Visual Check   
					Thermal Cycling   
					Humidity   
					-5 °C to +70 °C, 500 cycles   
					Visual Check   
					Visual Check   
					85% relative humidity, 55 °C, 1000 hours   
					Notes:   
					1.   
					The above tests should be performed on a sample size of at least 12 assemblies from three lots of   
					material.   
					Additional pass/fail criteria may be added at the discretion of the user.   
					2.   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process for Embedded Applications   
					June 2008   
					Order Number: 320028-001   
					TDG   
					28   
					 
					 
				Core™ 2 Duo Mobile Processors—Thermal Solution Component Suppliers   
					Appendix A Thermal Solution Component Suppliers   
					These vendors and devices are listed by Intel as a convenience to Intel’s general customer base. Intel   
					does not make any representations or warranties whatsoever regarding quality, reliability,   
					functionality, or compatibility of these devices. This list and/or these devices may be subject to   
					change without notice.   
					Note:   
					The enabled components may not be currently available from all suppliers. Contact the   
					supplier directly to verify availability.   
					Table 5.   
					Reference Heatsink   
					Part   
					Part Number   
					Contact Information   
					AdvancedTCA* passive heatsink assembly   
					1U+ passive heatsink assembly   
					ECC-00177-01-GP   
					ECC-00179-01-GP   
					ECC-00178-01-GP   
					Cooler Master*   
					Wendy Lin   
					
					(510)770-8566 ext 211   
					cPCI passive heatsink assembly   
					Honeywell*   
					Paula Knoll   
					
					(858) 279-2956   
					Thermal Interface Material   
					PCM45F   
					Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide   
					TDG   
					29   
					June 2008   
					Order Number: 320028-001   
					 
					 
				 |