2.4 Adjustment at Installation  
The PM-30 monitors the performance of a radar set by comparing its present performance  
with the initial performance achieved at installation. In order to establish good reference of  
comparisons, and eventual high-accuracy indications, the PM-30 must be properly adjusted  
at installation.  
Adjustment Procedure  
1. Confirm the front cover of the Performance Monitor is firmly secured with 8 fixing  
screws. (If not, microwave leakage will occur, resulting in misadjustment of attenuator  
ATT02 and eventual poor indicating accuracy.) Note that it is prohibited to open the front  
cover.  
2. Remove the cap bolts of attenuators ATT01 (RX) and ATT02 (TX) provided on the top  
side of the Performance Monitor.  
3. Put the radar in transmit mode.  
4. Set the radar controls as follows:  
RANGE:  
24 nm  
BRILLIANCE: For optimum picture brightness (around 2 o’clock position)  
GAIN:  
For a slight noise level on the display (around 2 o’clock position)  
Minimum (fully CW)  
Best tuning point  
STC/FTC:  
TUNING:  
SCANNER:  
ON (antenna rotating)  
5. Activate the Performance Monitor by operating the switch on the radar display, or by  
turning on the POWER switch of the Switch Box. Wait a while (about one minute) until  
the arc patterns displayed on the radar completely stabilized.  
6. Operating the VRM control, measure the range to the innermost arc displayed on the  
radar screen.  
7. Adjust attenuator ATT01 of the receiving circuit so that the innermost arc is displayed  
within the range 12 ±0.5 nm. Clockwise rotation of ATT01 increases the range;  
counterclockwise rotation decreases it.  
Note: Arcs may disappear or freeze when the attenuator setting is out of the adjustment  
range, and adjustment of the attenuator alone cannot clear the problem. In this case,  
turn the attenuator fully counterclockwise, turn it about 1 1/2 turns and then turn  
the power off and on again. Adjust the attenuator slowly in about 5 degree turns; a  
slight turn yields large change.  
8. Adjust transmitting circuit’s attenuator ATT02 so that the outermost arc (4th from inside)  
is slightly visible. Clockwise rotation of ATT02 increases the intensity of the arcs;  
counterclockwise rotation decreases it.  
12  

Frigidaire FFEC3603LW User Manual
EverFocus EN 7519C User Manual
Electrolux 922068 User Manual
Eizo RADI FORCE RX430 User Manual
Dell UltraScan 4476T User Manual
Avaya Desktop Charger User Manual
Avaya 1030 User Manual
ARM Cortex R4F User Manual
AG Neovo Neovo Touch Series TS 15S User Manual
AG Neovo Neovo E RX W19 User Manual