2. Aiming  
DUALBRITE  
The coverage area for the sensor is shown in Figure 2. The sensor  
should be aimed so that the motion to be detected is in front of and  
across the coverage area. The sensor should be aimed looking out  
at a horizontal angle. To reduce false triggering, point the sensor  
away from traffic areas, air conditioners, dryer vents, water pools,  
or anything which may move or change temperature rapidly.  
Replacement  
Sensor Head  
Models 3009701 / 3209996  
Note: Installation of this light control should be done only by  
those with experience in 120 Volt household wiring. Install in  
accordance with local codes. Some local codes may require that  
a licensed electrician install the light control.  
240°  
8 Ft.  
This light control automatically turns on lights when motion is  
detected. On-time is selectable from Off, 1, 5, or 20 minutes. A  
photocell keeps the lights off during the day. Patented DUALBRITE  
®
100 Ft.  
timer provides accent lighting.  
Figure 2 - Coverage Angles  
1. Installation  
3.Testing  
CAUTION: Always turn the circuit breaker off when wir-  
ing the fixture.  
Turn the power back on at the circuit breaker. Turn the light  
switch on.  
1. Remove the existing fixture.  
Note: When first turned on wait about 1 1/2 minutes for the circuitry  
to calibrate.  
2. After screwing the sensor into the wall plate, connect the junc-  
tion box wires to the light control wires as shown in Figure 1:  
Black sensor wire to the black (HOT) house wire.  
White sensor wire to all white (NEUTRAL) house and lamp  
wires.  
Put the ON-TIME switch on the bottom of the sensor in the TEST  
position.Youcannowwalkinfrontoftheunitandthelightswillcome  
on for about 5 seconds. The TEST mode works both day and night.  
Red (SWITCHED HOT) sensor wire to black lamp wires.  
Walk through the coverage area and point the sensor to obtain the  
desired coverage area. Adjust sensitivity as needed. Use RANGE  
BOOST only if required.  
3. Mount light fixture according to the instructions that came with  
your fixture.  
RED Sensor Wire and  
BLACK Lamp Wires  
All WHITE Wires  
Junction Box  
4. Operation  
For motion sensing, put the ON-TIME switch on the bottom of  
thesensorinthe1,5,or20minuteposition.Whenmotionisdetected,  
the lights will come on the selected time. Note: The photocell keeps  
the lights from turning on in daylight.  
Lamp  
Holders  
To keep lights on all night, flip the light switch off for 1 second  
then back on. To return the sensor to the motion sensing mode, flip  
the light switch off for 1 second then back on. At dawn, the control  
will return to the motion sensing mode and shut off.  
®
For accent lighting, set the DUALBRITE switch to the 3, 6, or  
Dusk-to-Dawn setting. The lights will turn on dim at sundown for  
the set time. When motion is sensed the lights will turn on full bright  
for the set ON-TIME period. The lights will return to dim during the  
BLACK Sensor Wire and  
BLACK Junction Box Wire  
®
set DUALBRITE period.  
Optional: Connect additional load across the white and  
red sensor wires. Total lighting load including lamp-  
heads on fixture(s) must not exceed 500W (4.2A).  
Specifications:  
Total Lighting Wattage.. Up to 500 Watts Maximum Incandescent  
Range .........................up to 70 ft.; up to 100 ft. with Range Boost  
Time Delay........................................................1, 5, or 20 minutes  
Figure 1 - Wiring Sensor Head  
CAUTION: Do not mount the sensor above or touching  
the lamps.Keep regular PAR-38 lamps at least 1" (25 mm)  
from the sensor. Halogen lamps should be kept at least  
2" (51 mm) from the sensor.The sensor bottom must be  
facingdownforbestcoverageandtoavoidwaterdamage  
and electrical shock.  
®
DUALBRITE ....................................Off, 3, 6 hours, Dusk-to-Dawn  
CAUTION:This product is to be used with a U.L.listed rain  
tightorwetlocationsuitableoutletbox.Dependingonthe  
installation, additional hardware may be required.  
Note: For under-eave installation, rotate the sensor head 180° by  
bending the sensor towards the clamp bracket. Rotate the sensor  
bottom clockwise away from the bracket.  
© 2005  
598-1231-00  

GE JGP636 User Manual
GE JGP336 User Manual
Ericsson DT360 User Manual
Electrolux EKM 70150 User Manual
Electrolux EHG 672 User Manual
Dell IN1720 User Manual
Cypress Perform CY7C1062DV33 User Manual
Cypress CY7C1177V18 User Manual
Cannon C50GCX User Manual
Black Box IC147A R2 User Manual