ATTO Technology Computer Hardware FC 41ES User Manual

Installation and Operation Manual  
Celerity FC host adapters  
Celerity FC-41EN  
4-Gb FC single channel host adapter  
Celerity FC-42EN  
4-Gb FC dual channel host adapter  
Celerity FC-44ES  
4-Gb FC quad channel host adapter  
Celerity FC-42ES  
4-Gb FC dual channel host adapter  
Celerity FC-41ES  
4-Gb FC single channel host adapter  
Celerity FC-42XS  
4-Gb FC dual channel host adapter  
Celerity FC-41XS  
4-Gb FC single channel host adapter  
Celerity FC-21PS  
2-Gb FC single channel host adapter  
© 2007 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective  
holders. No part of this manual may be reproduced in any form or by any means without the express written  
permission of ATTO Technology, Inc.  
3/2007  
Document Control Number: PRMA-0344-000  
Contents  
3 Installing and updating drivers .........................................................13  
ATTO Technology Inc.Celerity FC Storage Adapters Installation and Operation Manual  
1 ATTO provides Fibre Channel solutions  
The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and  
scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching,  
backup and data management. Specifically designed to enhance the functionality of third party fabric  
hardware and software, Celerity FC products are the industry-leading platform for storage connectivity.  
Celerity FC-41EN Adapter  
The Celerity FC-41EN is a single-channel host  
adapter. With 4-Gb FC speeds of up to 800 MB/sec.,  
the FC-41EN supports the most demanding  
application requirements.  
Environmental & physical specifications  
Conforms to PCIe low profile form factor  
specifications  
Operating temperature: 0 to 45º C (32-113º F)  
Storage temperature: -40 to 70ºC (-40 to 158º F)  
Relative humidity: 10 to 90% non-condensing  
100 lf/m (minimum) airflow recommended  
Conforms to PCI Express low-profile form-factor  
specification  
The FC-41EN takes advantage of the latest in host  
interconnect technology, PCI Express, a serial, high-  
speed connection that supports aggregate throughout  
up to 2 GB/sec.full-duplex. The FC-41EN is software  
compatible with existing PCI and PCI-X products  
using the same device drivers as other Celerity FC  
family products, simplifying user installation and  
support. It is backward compatible with existing 2-Gb  
and 1-Gb FC infrastructures, protecting existing  
technology investments.  
12V @ 0.5A (max)  
Length: 5.600 inches  
Height: 2.712 inches  
RoHS compliant  
External connectivity  
Easy-to-install full and low-profile connection  
plates  
Hardware specifications  
External LEDs for on-line and speed status  
A pluggable optical LC SFP transceiver included  
1 Fibre Channel port  
4-Gigabit data transfer rate  
800 MB/sec. maximum full-duplex throughput  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,  
FC-AL2, FC-PLDA, FC-FLA  
Software specifications  
Windows XP, 2000, Server 2003 and Vista  
Mac® OS X (10.4.x or later)  
Red Hat Linux (2.4 and 2.6 kernels)  
SUSE Linux (2.6 kernel)  
Flash ROM for easy field upgrades  
FC Class 3 support  
Local management and diagnostics  
Buffer credits: 4  
Advanced FC capabilities  
Supports SNIA HBA API  
On-demand automatic negotiation between 4-  
Gb, 2-Gb and 1-Gb Fibre Channel  
Supports initiator and target modes  
Supports Windows® FDMI and WMI  
Supports exclusive ATTO Advanced Data  
Streaming (ADS™) technology  
Host bus specifications  
x4 mechanical and x4 electrical PCI Express  
interconnect  
Conforms to PCI Express Base Spec 1.0a  
Conforms to PCI Express CEM Spec 1.0a  
1 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
   
Celerity FC-42EN Adapter  
Supports initiator and target modes  
Supports Windows FDMI and WMI  
Supports exclusive ATTO Advanced Data  
Streaming (ADS) technology  
The Celerity FC-42EN is a dual-channel host adapter,  
providing port density for Enterprise server and  
workstation applications. With 4-Gb FC speeds of up  
to 800 MB/sec.full-duplex per channel, the FC-42EN  
supports the most demanding application  
requirements.  
Host bus specifications  
x4 mechanical and x4 electrical PCI Express  
interconnect  
Conforms to PCI Express Base Spec 1.0a  
Conforms to PCI Express CEM Spec 1.0a  
The FC-42EN takes advantage of the latest in host  
interconnect technology, PCI Express, a serial, high-  
speed connection that supports aggregate throughout  
up to 2 GB/sec. The FC-42EN is software compatible  
with existing PCI and PCI-X products using the same  
device drivers as other Celerity FC family products,  
simplifying user installation and support. It is  
backward compatible with existing 2-Gb and 1-Gb FC  
infrastructures, protecting existing technology  
investments.  
Environmental & physical specifications  
Operating temperature: 0-45º C (32º to 113º F)  
Storage temperature:-40 to 70ºC (-40º to 158º F)  
Relative humidity: 10 to 90% non-condensing  
100 lf/m (minimum) airflow recommended  
Conforms to PCI Express low-profile form-factor  
specification  
12V @ 0.5A (max)  
Length: 5.600 inches  
Height: 2.712 inches  
RoHS compliant  
Hardware specifications  
2 independent Fibre Channel ports  
4-Gigabit data transfer rates per channel  
800 MB/sec. maximum full-duplex throughput  
per channel  
External connectivity  
Easy-to-install full and low-profile connection  
plates  
External LEDs for on-line and speed status for  
each channel  
2 pluggable optical LC SFP transceivers  
included  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,  
FC-AL2, FC-PLDA, FC-FLA  
Flash ROM for easy field upgrades  
FC Class 3 support  
Local management and diagnostics  
Buffer credits: 4  
Software specifications  
Windows XP, 2000, Server 2003 and Vista  
Mac OS X (10.4.x or later)  
Red Hat Linux (2.4 and 2.6 kernels)  
SUSE Linux (2.6 kernel)  
Advanced FC capabilities  
Supports SNIA HBA API  
On-demand automatic negotiation between 4-  
Gb, 2-Gb and 1-Gb Fibre Channel  
2
 
Celerity FC-44ES Adapter  
Conforms to PCI Express CEM Spec 1.0a  
PCI Express to PCI/PCI-X Bridge spec 1.0  
The Celerity FC-44ES uses PCI Express Interconnect  
and 4-Gigabit Fibre Channel to provide 4-Gb FC  
speeds of up to 800 MB/sec. per channel. The FC-  
44ES supports high-definition video, rich content  
databases and other high bandwidth environments.  
Environmental & physical specifications  
Conforms to PCI standard height, half length  
form-factor specifications  
Length: 6.525 inches  
Height: 3.81 inches  
Operating temperature: 0-45ºC (32-113ºF)  
Storage temperature: -40 to 70ºC (-40 to 158ºF)  
Relative humidity: 5 to 95% non-condensing  
12V@ 2.1A (max.)  
3.3V @ 3.0A (max.)  
100 lf/m (minimum) airflow recommended  
RoHS compliant  
The FC-44ES uses PCI Express, a serial, high-speed  
connection that supports aggregate throughput up to 4  
GB/sec. (x8 PCIe) full-duplex. With software  
compatible with existing PCI and PCI-X products, the  
FC-44ES uses the same device drivers as other  
Celerity FC family products, simplifying installation  
and support.  
Hardware specifications  
4 independent Fibre Channel ports  
4-Gigabit data transfer rates per channel  
800 MB/sec. maximum full-duplex throughput  
per channel  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP,  
FC-AL2, FC-PLDA, FC-FLA  
Flash ROM for easy field upgrades  
FC Class 3 support  
Local management and diagnostics  
Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes  
External connectivity  
Easy-to-install full height connection plate  
External LEDs for on-line and speed status for  
each channel  
4 pluggable optical LC SFP transceivers  
included  
Software specifications  
Windows XP, 2000, Server 2003 and Vista  
Mac OS X (10.4.x or later)  
Red Hat Linux (2.4 and 2.6 kernel)  
SUSE Linux (2.6 kernel)  
Advanced FC capabilities  
Supports SNIA HBA API  
On-demand automatic negotiation among 4-Gb,  
2-Gb and 1-Gb Fibre Channel  
Supports target and initiator modes  
Supports Windows FDMI and WMI  
Supports exclusive ATTO Advanced Data  
Streaming (ADS) Technology  
Host bus specifications  
x8 mechanical and x8 electrical PCI Express  
Interconnect  
Conforms to PCI Express Base Spec 1.0a  
3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
 
Celerity FC-42ES Adapter  
PCI Express to PCI/PCI-X Bridge spec 1.0  
The Celerity FC-42ES is a dual-channel host adapter  
providing port density for Enterprise server and  
workstation applications. With 4-Gb FC speeds of up  
to 800 MB/sec. per channel, the FC-42ES supports the  
most demanding application requirements.  
Environmental & physical specifications  
Operating temperature: 0-45ºC (32º-113ºF)  
Storage temperature: -40º to 70ºC (-40º to  
158ºF)  
Relative humidity: 5 to 95% non-condensing  
100 lf/m (minimum) airflow recommended  
Conforms to PCI half height, half length form-  
factor specifications  
12V@ 04A (max.); 3.3V @ 1.5A (max.)  
Length: 5.6 inches  
Additionally the FC-42ES takes advantage of the latest  
in host interconnect technology, PCI Express, a serial,  
high-speed connection that supports aggregate  
throughput up to 4 GB/sec. (x8 PCIe) full-duplex. The  
FC-42ES is software compatible with existing PCI and  
PCI-X products using the same device drivers as other  
Celerity FC family products, simplifying user  
installation and support. It is backward compatible  
with existing 2-Gb and 1-Gb Fibre Channel  
Height: 2.712 inches  
RoHS compliant  
External connectivity  
Easy-to-install full height connection plate  
External LEDs for on-line and speed status for  
each channel  
2 pluggable optical LC SFP transceivers  
included  
infrastructure, protecting existing technology.  
Hardware specifications  
2 independent Fibre Channel ports  
4-Gigabit data transfer rates per channel  
800 MB/sec. maximum full-duplex throughput  
per channel  
Software specifications  
Windows XP, 2000, Server 2003 and Vista  
Mac OS X (10.4.x or later)  
Red Hat Linux (2.4 and 2.6 kernel)  
SUSE Linux (2.6 kernel)  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
ANSI Fibre Channel: FC-PH, FC-AL, FC-AL2,  
FC-FCP, FC-PLDA, FC-FLA  
Flash ROM for easy field upgrades  
FC Class 3 support  
Local management and diagnostics  
Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes  
Advanced FC capabilities  
Supports SNIA HBA API  
On-demand automatic negotiation among 4-Gb,  
2-Gb and 1-Gb Fibre Channel  
Supports target and initiator modes  
Supports Windows FDMI and WMI  
Supports exclusive ATTO Advanced Data  
Streaming (ADS) Technology  
Host bus specifications  
x4 mechanical and x4 electrical PCI Express  
interconnect (RoHS compliant)  
Conforms to PCI Express Base Spec 1.0a  
Conforms to PCI Express CEM Spec 1.0a  
4
 
Celerity FC-41ES Adapter  
The Celerity FC-41ES is a single-channel host adapter  
providing support for the most demanding application  
requirements. With 4-Gb FC speeds of up to 800  
MB/sec. per channel, the FC-41ES is a cost effective  
connectivity solution for environments requiring  
maximum throughput.  
Environmental & physical specifications  
Conforms to PCIe low profile form factor  
specifications  
Length: 5.600 inches  
Height: 2.712 inches  
Operating temperature: 0-45ºC (32º-113ºF)  
Storage temperature: -40º to 70ºC (-40º to  
158ºF)  
The FC-41ES also takes advantage of the latest in host  
interconnect technology: PCI Express, a serial, high-  
speed connection that supports aggregate throughput  
up to 2 GB/sec. (x4 PCIe) full-duplex. The FC-41ES is  
software compatible with existing PCI and PCI-X  
products using the same device drivers as other  
Celerity FC products, simplifying user installation and  
support. It is backward compatible with existing 2-Gb  
and 1-Gb Fibre Channel infrastructure, protecting  
existing technology investments.  
Relative humidity: 5 to 95% non-condensing  
100 lf/m (minimum) airflow recommended  
Power: 12V@ 0.4A max; [email protected] max.  
RoHS compliant  
External connectivity  
Easy-to-install full height connection bracket  
External LEDs for on-line and speed status  
Pluggable optical LC SFP transceiver included  
Software specifications  
Hardware specifications  
Windows XP, 2000, Server 2003 and Vista  
Red Hat Linux (2.4 and 2.6 kernel)  
SUSE Linux (2.6 kernel)  
1 Fibre Channel port  
4-Gigabit FC data transfer rates  
800 MB/sec. maximum full-duplex throughput  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP,  
FC-AL2, FC-PLDA, FC-FLA  
Mac OS X (10.4.x or later)  
Flash ROM for easy field upgrades  
FC Class 3 support  
Local management and diagnostics  
Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes  
Advanced FC capabilities  
Supports SNIA HBA API  
On-demand automatic negotiation among 4-Gb,  
2-Gb and 1-Gb Fibre Channel  
Supports target and initiator modes  
Supports Windows FDMI and WMI  
Features exclusive Advanced Data Streaming  
(ADS) Technology  
Host bus specifications  
x4 mechanical and x4 electrical PCI Express  
interconnect  
Supports PCI Express Base Spec 1.0a and  
CEM Spec 1.0a  
Supports PCI Express to PCI/PCI-X bridge spec  
1.0  
5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
 
Celerity FC-42XS Adapter  
Height: 2.536 inches  
The dual-channel Celerity FC-42XS host adapter  
provides the highest available throughput for Fibre  
Channel applications while protecting technology  
investments via backward compatibility with existing  
infrastructure.  
Operating temperature: 0-45ºC (32º-113ºF)  
Storage temperature: -40º to 70ºC (-40º to  
158ºF)  
Relative humidity: 5 to 95% non-condensing  
3.3V@ 1.5A (max.)  
With speeds of up to 800 MB/sec. per channel, the FC-  
42XS is capable of supporting the most intensive data  
applications.  
100 lf/m (minimum) airflow recommended  
RoHS compliant  
External connectivity  
To ensure a smooth transition path, the FC-42XS  
leverages the existing Celerity FC software hardware  
architecture, allowing ATTO to deliver industry-  
leading quality and stable software architecture.  
Easy-to-install full height connection plate  
External LEDs for on-line and speed status for  
each channel  
2 optical LC SFP transceivers included  
Hardware specifications  
Software specifications  
2 independent Fibre Channel ports  
4-Gigabit data transfer rates per channel  
800 MB/sec. maximum full-duplex throughput  
per channel  
Windows XP, 2000, Server 2003 and Vista  
Red Hat Linux (2.4 and 2.6 kernel)  
SUSE Linux (2.6 kernel)  
Mac OS X  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,  
FC-AL2, FC-PLDA, FC-FLA  
Flash ROM for easy field upgrades  
FC Class 3 support  
Local management and diagnostics  
Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes  
Advanced FC capabilities  
Supports SNIA HBA API  
On-demand automatic negotiation among 4-Gb,  
2-Gb and 1-Gb Fibre Channel  
Supports target and initiator modes  
Supports Windows FDMI and WMI  
Includes exclusive ATTO Advanced Data  
Streaming (ADS) Technology  
PCI bus specifications  
64-bit, 133 MHz PCI-X  
PCI-X 1.0a compliant  
PCI 2.2 compliant  
3.3V PCI signaling only  
Environmental & physical specifications  
Conforms to PCI low profile form factor  
standards  
Length: 6.600 inches  
6
 
Celerity FC-41XS Adapter  
The single-channel Celerity FC-41XS provides speeds  
of up to 800 MB/sec. using full 4-Gigabit Fibre  
Channel performance while being fully backward-  
compatible with existing 2-GB and 1-Gb Fibre  
Channel infrastructure, protecting existing technology  
investments. It is capable of supporting the most data-  
intense applications.  
Environmental & physical specifications  
Conforms to PCI low profile form factor  
standards  
Length: 6.600 inches  
Height: 2.536 inches  
Operating temperature: 0-45ºC (32º-113ºF)  
Storage temperature: -40º to 70ºC (-40º to  
158ºF)  
Hardware specifications  
Relative humidity: 5 to 95% non-condensing  
3.3V@ 1.5A (max.)  
100 lf/m (minimum) airflow recommended  
RoHS compliant  
1 Fibre Channel port  
4-Gigabit data transfer rates  
800 MB/sec. maximum full-duplex throughput  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,  
FC-AL2, FC-PLDA, FC-FLA  
External connectivity  
Easy-to-install full height connection plate  
External LEDs for on-line and speed status  
Optical LC SFP transceiver included  
Flash ROM for easy field upgrades  
FC Class 3 support  
Local management and diagnostics  
Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes  
Software specifications  
Windows XP, 2000, Server 2003 and Vista  
Red Hat Linux (2.4 and 2.6 kernel)  
SUSE Linux (2.6 kernel)  
Advanced FC capabilities  
Mac OS X  
Supports SNIA HBA API  
On-demand automatic  
negotiation among 4-Gb, 2-  
Gb and 1-Gb Fibre Channel  
Supports target and initiator  
modes  
Supports Windows FDMI and  
WMI  
Includes exclusive ATTO  
Advanced Data Streaming  
(ADS) Technology  
PCI bus specifications  
64-bit, 133 MHz PCI-X  
PCI-X 1.0a compliant  
PCI 2.2 compliant  
3.3V PCI signaling only  
7 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
 
Celerity FC-21PS Adapter  
Includes exclusive ATTO Advanced Data  
Streaming (ADS) Technology  
The Celerity FC-21PS Fibre Channel host adapter  
provides a single 2-Gb Fibre Channel connection from  
host devices to the Storage Area Network (SAN)  
fabric.  
PCI bus specifications  
64-bit/32-bit, 66/33 MHz PCI compatible  
PCI 2.3 compliant  
3.3V and 5V PCI signaling with universal  
connector  
The FC-21PS supports the leading operating systems,  
providing a single solution for all connectivity needs.  
As with all Celerity FC products, the FC-21PS is  
designed for high-quality data transmission, ensuring  
that critical information is delivered correctly the first  
time to reduce fabric traffic and improve overall fabric  
efficiency.  
Environmental & physical specifications  
Conforms to PCI low profile form factor  
standards  
Length: 6.600 inches  
Height: 2.536 inches  
Hardware specifications  
Operating temperature: 0-45ºC (32º-113ºF)  
Storage temperature: -40º to 70ºC (-40º to  
158ºF)  
Relative humidity: 5 to 95% non-condensing  
5V@ 1.5A (max.)  
1 Fibre Channel port  
400 MB/sec. throughput full-duplex  
Supports all FC topologies: direct fabric,  
arbitrated loop and point-to-point  
Flash ROM for easy field upgrades  
Simultaneous multi-protocol support  
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,  
FC-AL2, FC-PLDA, FC-FLA, IETF-IPFC  
100 lf/m (minimum) airflow recommended  
External connectivity  
Easy-to-install full height connection plate  
Integrated optical LC SFF fixed transceiver  
External LEDs for on-line and speed status  
Advanced FC capabilities  
Supports SNIA HBA API  
On-demand, automatic negotiation between 2-  
Gb and 1-Gb Fibre Channel  
Software specifications  
Supports target and initiator modes  
Supports Windows FDMI and WMI  
8
 
Celerity selection guide  
Celerity  
FC-42ES  
FC-42EN  
Celerity  
FC-41ES  
FC-41EN  
Celerity  
FC-44ES  
Celerity  
FC-42XS  
Celerity  
FC-41XS  
Celerity  
FC-21PS  
Product Features  
4
2
1
2
1
1
Fibre Channel Ports  
FC protocol  
4-Gb  
4-Gb  
4-Gb  
4-Gb  
4-Gb  
2-Gb  
Maximum Transfer Rate (half  
duplex)  
1.6 GB/sec  
2 GB/sec  
800 MB/sec  
400 MB/sec  
800 MB/sec  
800 MB/sec  
400 MB/sec  
800 MB/sec  
200 MB/sec  
400 MB/sec  
Maximum Transfer Rate (full-  
duplex)  
1 GB/sec (ES)  
1.6 GB/sec (EN)  
1
1 GB/sec  
PCIe  
8 lane  
PCIe  
4 lane  
PCIe  
4 lane  
PCI-X  
64-bit  
PCI-X  
64-bit  
PCI-X  
64-bit  
Bus Type  
3
Bus Characteristics  
2
2
2
133 MHz  
133 MHz  
133 MHz  
SFP LC  
SFP LC  
SFP LC  
SFP LC  
SFP LC  
SFF LC  
Optical Interface  
300m@2-Gb  
150m@4-Gb  
300m@2-Gb  
150m@4-Gb  
300m@2-Gb  
150m@4-Gb  
300m@2-Gb  
150m@4-Gb  
300m@2-Gb  
150m@4-Gb  
500m@1-Gb  
300m@2-Gb  
Maximum Cable Length  
Low Profile form factor  
ATTO Advanced Data Streaming  
(ADS) Technology  
3
Software RAID support  
Developer's Kit (Target Mode &  
API)  
Windows XP, 2000, Server 2003  
and Vista support  
Linux (Red Hat, SUSE) driver  
Macintosh OS X driver  
Novell Netware support  
Solaris support  
Free BSD  
RoHS compliant  
1
2
3
Performance ceiling is constrained by 133 MHz PCI-X bus transfer speed  
Backward compatible to 32-bit and 33 MHz PCI; FC-21PS is 3.3V/5V Universal  
ATTO ExpressStripe for OS X available; Express Power Center and other software RAID supported for Windows  
9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
 
10  
2 Fibre Channel is a key technology for storage  
Fibre Channel is a serial communications technology designed to transfer large amounts of data among  
a variety of hardware systems over long distances. It is a key technology for applications that require  
shared, high bandwidth access to storage.  
Fibre Channel provides a logical, point-to-point,  
serial channel for the transfer of data between a  
buffer at a source device and a buffer at a  
destination device. It moves buffer contents from  
one port to another, without regard to the format  
or meaning of the data so different upper level  
protocols are able to run over Fibre Channel  
hardware.  
The Fibre Channel architecture is structured as a  
hierarchical set of protocol layers. Defined within  
these layers are rules for signal interfaces, serial  
encoding and decoding, error control, frame  
format and communications protocols.  
Glossary  
Some terms used in the Fibre Channel industry are defined below. More information is available through  
the ATTO Technology website (www.attotech.com), the Fibre Channel Industry Association  
(www.fibrechannel.com), Cern (www.cern.ch), the Storage Area Networking Industry Association  
(www.snia.org), and the Fibre Channel Consortium (www.iol.unh.edu/consortiums, click on FC)  
.
Term  
Definition  
ANSI  
American National Standards Institute  
arbitrate  
process of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop  
at the same time  
arbitrated loop  
a loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can  
communicate at one time; low-cost solution which may or may not use hubs and switches  
auto negotiation  
hardware senses and automatically responds depending on configuration  
BER  
bit  
Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent  
smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1  
bus  
a collection of unbroken signal lines used to transmit information from one part of a computer  
system to another; taps on the lines connect devices to the bus  
byte  
an ordered set of 8 bits  
channel  
CPU  
a point-to-point link which transports data from one point to another  
Central Processing Unit: the portion of the computer that actually performs computations  
CRC  
Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received  
and transmitted data; if no error has occurred during transmission, the CRC for both received and  
transmitted data should be the same  
destination  
address  
a value in the frame header of each frame which identifies the port in the node where the frame is  
being sent  
device driver  
DMA  
a program that allows a microprocessor to direct the operation of a peripheral device  
Direct Memory Access: a way to move data from a storage device directly to RAM without using  
the CPU’s resources  
DMA bus master allows a peripheral to control the flow of data to and from system memory by block as opposed to  
allowing the processor to control the data by bytes (PIO or programmed I/O)  
11 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
   
Term  
Definition  
fabric  
a Fibre Channel switch of two or more Fibre Channel switches interconnected to physically  
transmit data between any two N_Ports on the switch or switches  
FC  
Fibre Channel  
F_port  
a port in the Fibre Channel fabric where a N_port may attach  
a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop  
an indivisible unit for transfer of information in Fibre Channel  
FL_port  
frame  
frame header  
full-duplex  
half duplex  
the first field in the frame containing the address and other control information about the frame  
a communication protocol which allows transmission in both directions at the same time  
a communication protocol which allows transmission in both directions, but only one direction at a  
time  
host  
a processor, usually a CPU and memory, which communicates with devices over an interface  
a component which originates a command  
initiator device  
L_port  
a port in an arbitrated loop, either a NL_port or a FL_port  
LED  
Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs  
are used as indicator lights on all sorts of electronic devices  
LUN  
Logical Unit Number: an identifier for a logical unit (0-7)  
multi-mode fiber an optical fiber which can carry several beams of light at once  
N_port  
a port attached to a node used with point to point or fabric configurations  
a port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration  
an initiating device; a component which originates a command  
NL_ port  
originator  
parity checking  
a method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in  
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error  
message occurs if the sum is not correct  
PCI  
Peripheral Component Interconnect. Allows peripherals to be connected directly to computer  
memory, bypassing the slower ISA and EISA busses  
point-to-point  
port  
a topology where two ports communicate  
an access point in a device: see N_port, NL_port, etc.  
port address  
also port number; the address, assigned by the PCI bus, through which commands are sent to a  
host adapter board  
port number  
receiver  
see port address  
the ultimate destination of data transmission; a terminal device  
scatter/gather  
a device driver feature which allows the host adapter to modify a transfer data pointer so that a  
single host adapter can access many segments of memory, minimizing interrupts and transfer  
overhead  
SCSI  
Small Computer Systems Interface: a processor-independent standard for system-level interface  
between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers,  
scanners, etc.  
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is  
nearly equal to the wavelength of the source  
topology  
logical layout of the parts of a computer system or network and their interconnections  
a transmitter/receiver module  
transceiver  
transfer rate  
the rate at which bytes or bits are transferred, as in megabytes or gigabits per second  
12  
3 Installing and updating drivers  
Before installing your Celerity adapter, you must configure your system to recognize and use it by  
installing drivers for your operating system.  
Configure your system to recognize and use your  
Celerity adapter by  
ATTO Celerity adapters ship with the latest  
firmware installed.  
installing drivers for your operating system  
updating the adapter firmware if necessary (refer  
The Celerity FC Installation CD shipped with  
your adapter contains the latest driver.  
The Installation CD automatically starts when  
inserted in the system CD-ROM drive. Navigate  
the easy-to-use HTML-based menu to find the  
driver that you want to install.  
Note  
If you already have one or more Celerity  
adapters installed and you are installing  
additional adapter(s), you do not need to  
perform any of these procedures unless you  
are updating a previously installed driver.  
If the CD does not automatically start, open the  
CD and click on autorun.bat  
.
Specialized configurations  
Some specialized applications may benefit from  
modification of adapter settings. The ATTO  
Utilities Installation and Operation Manual  
provides detailed information on using ATTO  
Technology configuration utilities found on the  
ATTO Utilities CD or downloaded from the  
ATTO website. For best performance, use the  
most recent device driver and flash version.  
Note  
Windows NT is only supported with Celerity  
driver version 1.31 or earlier. If you are using  
Windows NT, contact your service  
representative.  
Mac OS X: Use the ATTO Configuration Tool on  
the ATTO Utilities CD, or download it from  
www.attotech.com, or use the Apple System  
Profiler.  
Verify the version based on your operating  
system.  
Linux: Use the ATTO Configuration Tool on the  
ATTO Utilities CD, or download it from  
www.attotech.com, or to find the driver version,  
examine /proc/scsi/celerityfc/X, where  
adapter’s host number.  
Windows: Use the ATTO Configuration Tool  
from the ATTO Utilities CD, or download it from  
www.attotech.com, or view the adapter boot  
string during system boot or look in the Device  
X
is the  
Manager  
.
Windows 2000/XP/Server 2003/Vista  
Five procedures are described below. Review  
each thoroughly to ensure that you are using the  
one that best fits your needs. If you have one or  
more Celerity FC adapters installed in your  
system and you are installing additional  
these procedures unless you are updating a  
previously installed driver.  
The Celerity FC Installation Disk can be the  
Installation CD shipped with your adapter, a  
folder containing the latest downloaded and  
expanded driver, or a Celerity FC installation  
floppy disk.  
adapter(s), you do not need to perform any of  
13 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
       
the wizard default settings to complete the  
installation.  
Upgrading an existing Celerity FC driver  
1
2
3
4
Log on to Windows as the System  
Administrator.  
Creating a boot disk  
Insert your Celerity FC Installation Disk and run  
autorun.bat  
Note  
In Windows Drivers, select your operating  
system version.  
The procedure described below does not  
apply to Windows Server 2003 for Itanium  
systems because the Celerity FC driver does  
not support boot functionality on Itanium  
systems.  
Click on Install Driver.  
Adding a Celerity FC adapter to an  
existing installation  
1
2
Start Windows text mode setup as found in the  
instructions provided with Windows.  
Note  
Press F6 when Windows Setup, displays. The  
setup program displays a prompt in the status  
window on the bottom left of the monitor. Setup  
continues to load files after you press F6.  
Complete this installation procedure before  
attaching any devices to the adapter.  
1
2
3
Complete the steps in Updating hardware flash  
on page 24 to pre-install the driver.  
3
A new window displays instructions to specify  
additional mass storage devices. Press S to  
install the ATTO Celerity as a storage device.  
Close Windows and turn off power to your PC  
when Setup prompts you to do so.  
4
5
6
Insert the Celerity FC installation diskette in  
drive A and press Enter.  
Install your new Celerity FC adapter into an  
available PCI expansion slot.  
a. If the Celerity FC adapter is replacing  
another adapter in the system, disconnect  
the FC cables from the adapter and  
remove the adapter from the system, or  
move the Celerity FC adapter to the PCI  
slot that the previous adapter occupied.  
b. Attach the appropriate FC cables to the  
Celerity FC adapter.  
A screen displays a list of Celerity FC adapters.  
Select your adapter and press Enter.  
Windows Setup loads the files from the floppy  
and then displays the screen described in Step  
2. The ATTO Celerity FC device should now be  
listed as detected.  
7
8
Repeat steps 2 to 6 for any other vendor-  
supplied driver installation disks.  
4
5
6
Close the computer chassis  
After all other drivers have been processed,  
press Enter and proceed with the rest of the  
Windows installation procedure.  
Turn on the power and restart Windows.  
During the boot process, Windows detects your  
Celerity FC adapter and the Found New  
Hardware Wizard is displayed.  
Note  
When Windows begins copying files to your  
hard disk, a display prompts you to insert the  
Celerity FC installation disk and any other  
vendor-supplied disks you used during  
custom installation. This is normal. The first  
time you inserted the disks, Windows loads  
the drivers into memory; the second time you  
insert the disk(s), Windows copies the driver  
to your hard disk.  
Follow the directions in the Found New  
Hardware Wizard, selecting the default  
settings for each adapter channel.  
7
8
Insert the Celerity FC Installation disk when  
asked to do so.  
When adapter installation is complete, the  
Found New Hardware Wizard displays an  
ATTO Phantom Device for each channel. Use  
14  
   
Creating a Celerity FC installation floppy  
Creating a floppy disk from a download  
1
Download the latest driver software from the  
ATTO website, www.attotech.com.  
The download is a self-extracting executable  
that expands the driver software package. Run  
the self-extracting executable and select a  
folder to place the expanded software package.  
Note  
You must have a floppy disk with the Celerity  
FC driver software to install a fresh copy of  
the Windows OS onto a disk attached to a  
Celerity FC adapter.  
2
1
Insert the Installation CD into a CD-ROM. The  
installation starts automatically.  
3
Navigate to the folder with the desired Celerity  
FC driver.  
If the Celerity FC installation does not start,  
navigate to the root of the CD and run  
autorun.bat  
Note  
The expanded software package contains a  
Miniport driver and may contain a StorPort  
driver. The Celerity FC Windows Miniport  
driver is in the base directory of the  
expanded software package. The Celerity  
FC Windows StorPort driver is in the  
StorPort subdirectory.  
2
3
4
Select Windows Drivers from the items on the  
left side of the screen.  
Select the appropriate CPU-based operating  
system from operating system choices.  
Select Create Miniport Driver Diskette or  
Create StorPort Driver Diskette for the  
desired operating system.  
4
Run makedisk.bat and follow the instructions  
for creating the floppy disk.  
5
Follow the instructions for creating the floppy  
disk.  
Mac OS X driver installation, update  
1
Extract the latest version of the device driver file  
to your desktop.  
3
Reboot your system for the changes to take  
effect.  
2
Double click the installer icon and follow the on  
screen prompts.  
Linux driver installation, update  
2
3
4
Download the appropriate version of the device  
driver from the ATTO website.  
Note  
You must have kernel header files for the  
appropriate kernel installed.  
At the command prompt, extract the file using  
the command tar -xfz <filename.tgz>  
You must be logged in as root  
.
Enter the directory created in the above step  
and type make install to overwrite any  
previously-installed driver.  
1
At the command prompt type rmmod  
celerityfc  
5
Start the driver by typing modprobe celerityfc  
15 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
   
16  
4 Hardware installation  
You need a basic understanding of Fibre Channel before installing the Celerity FC host adapter. Please  
refer to Fibre Channel is a key technology for storage on page 11 for a list of related websites.  
WWN 0 all adapters  
CAUTION  
WWN 1: 44ES, 42ES, 42XS, 42EN  
Back up your system data before changing  
or installing any hardware.  
WWN 2 44ES  
WWN 3 44ES  
System requirements  
Installation  
The Celerity FC host adapter package contains the  
host adapter, the ATTO Utilities CD and a  
CAUTION  
Celerity FC host adapters contain  
components that are sensitive to  
electrostatic discharge (ESD). ESD can  
cause damage to the Celerity FC host  
adapter. Please follow standard methods to  
avoid ESD.  
warranty and registration card. If any of these  
items are missing, contact your ATTO authorized  
sales representative.  
To install and use the Celerity Fibre Channel host  
adapter you need  
A computer with an available PCI, PCI-X or PCI  
Express expansion slot  
1
2
Install the latest drivers. Refer to Installing and  
The complete Celerity FC host adapter package  
Power down the computer and unplug the  
computer from all power sources.  
Fibre Channel address  
3
4
Open the case.  
Install the Celerity FC host adapter in any open  
PCI, PCI-X or PCI Express expansion slot. If  
you have questions about how to install an  
expansion card in your system, consult your  
computer’s documentation.  
Celerity FC adapters are configured with a unique  
address designated by the Institute of Electrical  
and Electronic Engineers. The WorldWide Port  
Name (WWN) and Node Name are the two  
components of the address assigned to Fibre  
Channel products. This address, stored in flash  
memory, allows the system to recognize the  
Celerity host adapter as a unique part of your  
configuration. The address is clearly marked on  
the back of the board for easy identification.  
Please keep a reference copy of the number in a  
safe place or write in the space provided on this  
page.  
Drawings of Celerity brackets begin on page 18  
and drawings of boards begin on page 20.  
Note  
The Celerity FC-41XS, and FC-42XS host  
adapters only fit in 3.3V slots.  
The Celerity FC-42ES, FC-41ES, FC-41EN  
and FC-42EN fit into x4, x8, or x16 mechanical  
PCI Express slots.  
If you have trouble seating your adapter in a 32-  
bit PCI bus computer, check to make sure the  
connector can accommodate 64-bit host  
adapters.  
Celerity FC host adapter WWNs are assigned for  
each channel. The WWN listed on your host  
adapter is assigned to the first channel (0).  
Sequential WWNs apply for additional channels.  
5
6
Connect Fibre Channel devices by inserting a  
Fibre Channel cable from the devices to the  
connectors on the Celerity FC host adapter until  
you hear a click.  
Close the case on the computer and power it  
up.  
17 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
 
Bracket details  
Exhibit 4-1 FC-41EN low profile and full height  
adapters  
Exhibit 4-3 FC-44ES Adapter  
Exhibit 4-4 FC-42ES low profile and full height  
adapters  
Exhibit 4-2 FC-42EN low profile and full height  
adapters  
18  
   
Exhibit 4-5 FC-41ES low profile and full height  
adapters  
Exhibit 4-7 FC-41XS low profile and full height  
adapters  
Exhibit 4-8 FC-21PS Adapter  
Exhibit 4-6 FC-42XS low profile and full height  
adapters  
19 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
Adapter board details  
Exhibit 4-9 FC-41EN  
Exhibit 4-10 FC-42EN  
20  
   
Exhibit 4-11 FC-44ES  
Exhibit 4-12 FC-42ES  
21 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
Exhibit 4-13 FC-41ES  
Exhibit 4-14 FC-42XS  
22  
Exhibit 4-15 FC-41XS  
Exhibit 4-16 FC-21PS  
23 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
5 Updating hardware flash  
Your Celerity FC host adapter was flashed before shipment, but the flash memory may need to be  
updated as new versions become available or if the factory-installed version becomes corrupt. Visit the  
ATTO website, www.attotech.com, to download the latest drivers and flash bundle.  
2
The download is a self-extracting executable  
that expands the driver software package. Run  
the self-extracting executable and select a  
folder in which to place the expanded software  
package.  
Hardware flash memory may need to be updated  
as new versions become available or if the  
factory-installed version becomes corrupt.  
Updating flash in all operating systems  
The expanded software package contains a  
Miniport driver and may contain a StorPort  
driver. The Celerity FC Windows Miniport driver  
is in the base directory of the expanded  
software package. The Celerity FC Windows  
StorPort driver is in the StorPort subdirectory.  
1
Download the most recent version of the  
Configuration Tool from the ATTO website.  
Refer to the ATTO Utilities Installation and  
Operation Manual for additional information on  
downloading and using the Configuration Tool.  
2
Download the proper flash bundle (adapter  
specific) from the ATTO website.  
3
4
Navigate to the folder with the desired Celerity  
FC driver.  
3
4
5
6
Extract these files to your desktop.  
Run makedisk.bat and follow the instructions  
for creating the floppy disk.  
Install the Configuration Tool on your system.  
Launch the Configuration Tool.  
Note  
In the Device window, select the adapter that  
needs to be updated.  
The flash update must be loaded from a  
floppy because CD-ROM drivers are not  
loaded at this point in the system boot  
process.  
7
In the Flash window, click on the Browse  
button to find the flash bundle that you  
previously downloaded to your desktop.  
5
6
Reboot the PC.  
8
9
Click Update to update your flash ROM.  
During the reboot, an ATTO Technology  
banner displays that the host adapter was  
detected.  
Reboot your system for the changes to take  
effect.  
7
Enter Control-F when prompted to begin the  
set-up utility within a few seconds after the  
banner appears.  
Updating flash on a PC  
You may update hardware flash on a PC using  
BIOS utilities.  
If you do not enter Control-F soon enough after  
the banner appears, repeat steps 5 and 6.  
Note  
8
9
In the utility, select the Upgrade Flash ROM  
option.  
BIOS utilities do not work on Itanium  
systems. Use the ATTO Configuration Tool  
to update flash on Itanium systems.  
Insert the disk into the drive slot.  
10 Follow the on-screen instructions.  
1
Download the latest driver software from the  
ATTO Technology website.  
11 Remove the disk and reboot your system for  
the flash ROM changes to take effect  
24  
   
6 Troubleshooting  
This chapter contains solutions for the most common problems you might encounter. If you need  
additional assistance, please refer to the ATTO Technology website, www.attotech.com, or contact an  
authorized ATTO Technology representative.  
Check that Fibre Channel devices are plugged  
into an AC outlet and are turned on before you  
add power to your computer.  
General suggestions  
Check each cable connection on every device.  
Verify all cables are in proper working condition.  
Loose or broken cables are often the cause of  
errors or problems.  
Mac OS X  
3
Verify the driver is loaded.  
Note  
a. Click on the adapter name in the  
Device Listing to view the Basic Info  
screen.  
The Celerity FC supports Mac OS X versions  
10.3 and later.  
b. If the Driver Information section  
indicates Unknown: driver not  
loaded, reinstall the driver. Refer to  
13.  
c. If reinstalling the driver does not fix the  
problem, contact an authorized ATTO  
representative.  
1
2
Open the ATTO Configuration Tool from the  
ATTO Utilities CD or download from the ATTO  
website. Refer to the ATTO Utilities Installation  
and Operation Manual for additional  
information.  
If the adapter does not appear in the Device  
Listing, make sure it is properly seated in the  
PCI slot.  
4
Reset the NVRAM for all channels to defaults  
and reboot. If the problem persists, contact an  
authorized ATTO representative.  
a. Remove power from the PC.  
b. Remove the case.  
c. Check the PCI slot.  
d. Replace the case.  
e. Apply power.  
Note  
When calling ATTO Technical Support,  
please have a printout of the IOreg listing  
and output from the Apple System Profiler  
available.  
Note  
If the Celerity adapter is properly seated and  
devices are still not accessible, contact an  
authorized ATTO representative.  
Windows 2000/XP/Server 2003/Vista  
If the card has been recently re-flashed, the new  
Windows driver must be installed. Follow the  
Procedures vary greatly: refer to the manual  
supplied with your system or call the computer  
supplier for configuration assistance.  
Windows 2000/XP/Server 2003/Vista are Plug-  
n-Play operating systems: be sure your  
computer’s BIOS is set accordingly.  
All of the external devices connected to the host  
adapter should be identified. If they do not  
appear in the Device Manager, the external  
devices or connection may not be working  
properly.  
If these do not solve the problem, re-flash the  
host adapter and re-install the Windows  
2000/XP/Server 2003/Vista driver. See  
For Intel-based PCs, check the computer CMOS  
setup and verify that the PCI slots are configured  
correctly.  
25 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
     
If the adapter has been identified but there is an  
exclamation point (!) on the listing, right click on  
the listing and select Uninstall.  
If the devices connected to the Celerity FC host  
adapter are not accessible  
1
2
3
4
Right-click My Computer.  
Select Properties.  
5
6
7
Reload the driver (see Installing and updating  
Select the Hardware tab.  
Select Device Manager.  
Reboot the system and repeat the installation  
process.  
If the Celerity FC host adapter does not appear  
under the SCSI and RAID controllers, remove  
power from the PC, open the case, and check  
that the Celerity FC adapter is properly seated in  
the PCI slot. Replace the case and apply power.  
If problems persist, contact your authorized  
ATTO Technology representative.  
Linux  
1
Verify the celerityfc driver is loaded with the  
3
Examine the contents of the file(s)  
/proc/scsi/celerityfc/X, where X is the  
adapter’s host number. This file contains details  
such as link status, connection speed and  
discovered devices.  
lsmod command. If lsmod does not show the  
driver, refer to the installation instructions to  
install and load the driver in Installing and  
2
Check the system log with the command  
dmesg. The celerityfc driver creates status  
messages during initialization. Make sure that  
all installed cards are properly detected and  
initialized.  
Note  
Advanced users only. Modify the driver  
makefile to enable debugging information.  
Upon loading, the celerityfc driverdisplays  
detailed debugging information which may  
help troubleshoot the problem.  
26  
 
Appendix A Standards and compliances  
The equipment described in this manual generates and uses radio frequency energy. The Technical  
Specification sheet for a particular Celerity FC host adapter list certifications for that model.  
FCC standards: radio and television interference  
This equipment has been tested and found to comply with the limits for a  
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are  
designed to provide reasonable protection against harmful interference in a residential installation. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause interference to radio communications. However,  
there is no guarantee that interference will not occur in a particular installation. If this equipment does  
cause interference to radio or television reception, which can be determined by turning the equipment  
off and on, the user is encouraged to try to correct the interference by one or more of the following  
measures:  
Reorient or relocate the receiving antenna  
Increase the separation between the equipment and receiver  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected  
Consult the dealer or an experienced radio/TV technician for help  
Canadian standards  
This Class B digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  
European standards  
Declaration of Conformity  
This following statement applies to the Celerity FC host adapter.  
This device has been tested in the basic operating configuration and found to be compliant with the  
following European Union standards: Application of Council Directive: 89/336/EEC  
Standard(s) to which conformity is declared: EN55024:2002; EN55022:2002 CLASS B  
This Declaration will only be valid when this product is used in conjunction with other CE approved  
devices and when the entire system is tested to the applicable CE standards and found to be compliant.  
Some ATTO Celerity cards comply with Directive 2002/95/EC on the Restriction of  
the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS).  
Contact your ATTO representative regarding RoHS compliant products.  
i ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
       
Usage restrictions  
The use of optical instruments with this product will increase eye hazard.  
The multimode transceiver is a Class 1 laser product complying with IEC 825-1 and FDA-21 CFR  
1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum  
ratings. The laser is non-OFC compliant as it is a Class 1 device.  
The optical ports of the modules must be terminated with an optical connector or with a dust plug.  
CAUTION  
Failure to adhere to the above restrictions could result in a modification that is considered an act of  
“manufacturing” and will require, under law, recertification of the modified product with the U.S. Food  
and Drug Administration (ref. 21 CFR 1040.10(i)).  
The following apply to the Celerity FC-42XS host adapter only  
This is a Class B product based on the standard of the Voluntary Control Council for Interference from  
Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a  
domestic environment, it may cause radio interference. Install and use the equipment according to the  
instruction manual.  
ii  
   
Appendix B Accessories  
The following Fibre Channel accessories are available through ATTO Technology and authorized  
resellers. Contact an ATTO Technology authorized sales representative to order.  
Optical Cables  
CBL-FCFI-05x  
CBL-LCSC-003  
CBL-LCSC-010  
5 m. cable– Duplex 50 Micron Multi-mode FC/Optical  
3 m. 50/125 optical cable (LC to SC)  
10 m. 50/125 optical cable (LC to SC)  
A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology.  
Please contact your ATTO sales representative for product descriptions and part number information.  
Fibre Channel and iSCSI solutions  
TM  
ATTO FibreBridge  
ATTO iPBridge  
Fibre Channel-to-SCSI bridge  
iSCSI to SCSI, iSCSI to Fibre Channel bridges  
SCSI solutions  
ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix C)  
SAS/SATA Solutions  
ATTO ExpressSAS family of SAS Adapters (see Appendix D)  
Software  
ATTO Utilities  
ATTO ExpressStripe  
Configuration and management software  
Mac OS X RAID and benchmark software  
ATTO Express Power CenterWindows-based striping utility  
iii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
 
Appendix C SCSI adapter selection guide  
Ultra 320 SCSI  
Product Features  
UL5D  
640  
UL5D LP  
640  
UL4D  
640  
UL4S  
320  
Max. transfer rate (MB/sec.)  
Low Voltage Differential  
Single-ended SCSI  
0/2  
30  
Number of SCSI Channels  
Number of SCSI IDs supported  
Low profile  
2/2  
30  
2/2  
30  
1/1  
30  
Large file transfers  
Cable distances (m)  
32-bit PCI compatible  
12.5  
12.5  
12.5  
12.5  
64-bit PCI compatible  
33 MHZ PCI  
133 MHZ PCI-X  
66 MHz PCI  
x4 PCI Express  
Windows 2000/XP, Server 2003/Vista support  
Linux support  
Mac OS X support  
Novell Netware support  
RoHS compliant  
iv  
 
Appendix D SAS adapter selection guide  
ATTO ExpressSAS RAID Adapters  
Product Features  
R348  
R380  
1
Max.transfer rate (full duplex)  
4 GB/sec.  
4 GB/sec.  
x8 PCI Express  
Number of ports  
8
8
Port configuration  
external/internal  
4/8  
8/0  
user selectable 4/4 or 0/8  
Connector type  
1 mini SAS (x4) SFF-8088 external 2 mini SAS (x4) SFF-8088 external  
2 mini SAS (x4) SFF-8087 internal  
Number of devices supported  
64 SAS/SATA targets  
128 virtual devices  
64 SAS/SATA targets  
128 virtual devices  
1.5 Gb SATA support  
3 Gb SATA II support  
3 Gb SAS support  
Cable distances  
Integrated RAID  
up to 8m  
up to 8m  
2
2
2
2
0, 1, 4, 5, 6 , 10, 50, 60 , JBOD,  
DVRAID  
0, 1, 4, 5, 6 , 10, 50, 60 , JBOD,  
DVRAID  
RAID Management Utility  
Global Hot Spares  
Event notification  
Memory (ECC)  
E-mail, pop-up, log file  
E-mail, pop-up, log file  
258 MB standard  
258 MB standard  
512 upgradeable (OEM)  
512 upgradeable (OEM)  
Advanced Data Streaming™  
Battery backup  
32-bit support  
optional  
optional  
64-bit support  
Windows 2000/CP, Server  
2003/Vista support  
Linux (Red Hat, SUSE) support  
Mac OS X support  
RoHS compliant  
Low profile  
1
Performance ceiling constrained by PCIe bus transfer speed  
Future support  
2
v ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual  
 
Appendix E Contact ATTO Technology, Inc.  
Customer service, sales information and technical support are available by phone Monday through Friday,  
Eastern Standard Time 8:00 a.m. to 8:00 p.m., or by e-mail and website 24-hours a day.  
ATTO Technology, Inc.  
155 CrossPoint Parkway  
Amherst, New York 14068  
(716) 691-1999 • voice  
(716) 691-9353 • fax  
ATTO Technology can also be reached via e-mail at the following addresses:  
Sales Support:  
Technical Support:  
vi  
 

HP Hewlett Packard HP Pavilion 23xi 23 C3Z94AA#ABA User Manual
Fisher Paykel CP 486GL User Manual
Electrolux SG 414 User Manual
Electrolux 726375 User Manual
Dell Computer Monitor ST2420L User Manual
Dacor Cooktop RR30NIFS[ C] User Manual
AT T E1112B User Manual
Asus Computer Monitor VW202XL User Manual
Aluratek Micro SD User Manual
Abit USA Corporation Computer Hardware AV8 User Manual