JVC SA K51U User Manual

OPTION HDD KIT  
SA-K51U  
INSTRUCTIONS  
R
For Customer Use:  
VICTOR COMPANY OF JAPAN, LIMITED  
Enter below the Serial No. which is  
located on the body. Retain this  
information for future reference.  
This instruction book is made from  
100% recycled paper.  
Model No.  
Serial No.  
SA-K51U  
is a registered trademark owned by VICTOR COMPANY OF JAPAN, LTD.  
is a registered trademark in Japan, the U.S.A., the U.K. and many other countries.  
© 2002 VICTOR COMPANY OF JAPAN, LIMITED  
Printed in Japan  
LLT0020-001A  
LLT0020-001A  
Safety Precautions  
Thank you for purchasing this product.  
(These instrustions are for SA-K51U)  
Features  
Before beginning to operate this unit, please read the instruction manual carefully in  
order to make sure that the best possible performance is obtained.  
Attaching the expansion hard disk SA-K51U to the VR-510U increases the memory capacity  
to 160 GB and makes long-time recording possible.  
Due to design modifications, data given in this  
instruction book are subject to possible change  
FOR USA AND CANADA  
without prior notice.  
CAUTION  
Precautions  
Ensure that the power to the VR-510U is off and the plug is removed from the power  
RISK OF ELECTRIC SHOCK  
WARNING:  
TO REDUCE THE RISK OF FIRE OR  
DO NOT OPEN  
socket before attaching the SA-K51U. Not doing so may result in a fire or electric shock.  
CAUTION:TO REDUCE THE RISK OF ELECTRIC  
SHOCK. DO NOT REMOVE COVER (OR  
BACK). NO USER-SERVICEABLE PARTS  
ELECTRIC SHOCK, DO NOT EXPOSE  
THIS APPLIANCE TO RAIN OR  
MOISTURE.  
Do not touch the edge of the metal frame, as there is the risk of injury.  
Users must not attach the SA-K51U themselves because there is the risk of a burn from  
an electric shock. Request your nearest JVC Service Center to perform the work. There  
will be a charge for the work.  
INSIDE.REFER  
SERVICING  
TO  
QUALIFIED SERVICE PERSONNEL.  
AVERTISSEMENT:  
POUR EVITER LES RISQUES  
D’INCENDIE OU D’ELECTRO-CUTION,  
NE PAS EXPOSER LAPPAREIL A  
LHUMIDITE OU A LA PLUIE.  
The lightning flash wish arrowhead  
symbol, within an equilateral triangle is  
intended to alert the user to the presence  
of uninsulated “dangerous voltage” within  
the product’s enclosure that may be of  
sufficient magnitude to constitute a risk  
of electric shock to persons.  
Any data recorded on the original hard disk will be lost when the SA-K51U is attached.  
INFORMATION (FOR CANADA)  
This Class B digital apparatus complies with  
Canadian ICES-003.  
The exclamation point within an  
equilateral triangle is intended to alert  
the user to the presence of important  
operating and maintenance (servicing)  
RENSEIGNEMENT (POUR CANADA)  
Cet appareil numérique de la Class B est conforme  
á la norme NMB-003 du Canada.  
instructions  
in  
the  
literature  
accompanying the appliance.  
Information for USA  
This device complies with part 15 of the FCC Rules.  
Changes or modifications not approved by JVC could  
void the user’s authority to operate the equipment.  
2
3
3. Fix the SA-K51U in place by inserting the screws (black) into the four screw holes of the  
stand and tightening them while the connector part of the SA-K51U is positioned so that  
it is faces the rear panel of the VR-510U.  
How to Attach  
First, set the ID of the hard disk drive to SLAVE.Refer to the instructions on how to set the  
ID shown on the top (side with the model-name label affixed) of the hard disk drive.  
* Keep the screws straight and steady when tightening them because the stand has  
non-threaded screw holes.  
1. Fix the SA-K51U in place by inserting the screws (silver) into the four screw holes of the  
stand and tightening them.  
Stand  
Fix in place so as the  
flap and the hard disk  
drives connectors are  
on opposite sides.  
Connector part  
4. Connect the hard disk power cable and flat cable to the connectors on the SA-K51U.  
Hard disk power cable  
SA-K51U  
2. Open the cover of the VR-510U and remove the clamp from the power cable for the hard  
disk.  
Flat cable  
Clamp  
Hard disk power cable  
4
5
4. Select 2.HDD MOUNT by turning the jog dial and then return the shuttle dial to the  
How to Mount  
SELECT position by turning it either clockwise or anticlockwise.  
The following describes how to operate the front panel of the VR-510U to mount the SA-  
K51U.  
The jog operation switches from J.DIR ↑ ↓ to J.DIR +.  
[
F U N C T I O N -  
F A C T O R Y S E T T I N G  
. H D D MO U N T  
1
]
J
. D I R –  
+
1
2
3
4
5
6
7
8
9
.
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
[
-
-
-
-
]
. D I  
. D I  
. D I  
. D I  
. D I  
. D I  
. D I  
P
P
P
P
P
P
P
P
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
0
1
2
3
4
5
6
7
1. Insert the plug into the plug socket and switch on the power switch of the VR-510U.  
The MOUNT ERROR message is displayed on the monitor.  
3
A L  
-
-
1 0  
-
-
0 2 S U N 1 8  
:
0 3  
:
3 8  
-
-
-
-
-
-
-
-
%
* It takes 10 to 20 seconds for the message to be displayed  
after the power has been switched on.  
* When the VR-510U is not receiving video input signals,  
INPUT SIG ERROR and MOUNT ERROR messages are  
displayed on the monitor alternatively.  
1 0 . D I  
MO U N T E R R O R  
5. Set to standard format (STD) or extended format (EXTN) by turning the jog dial.  
Turning the jog dial switches between OFF STD EXTN  
OFF in order.  
Selects whether the hard disk is formatted with standard  
or extended mode.  
When the disk is formatted, all existing data on the hard  
disk will be erased.  
[
F U N C T I O N -  
F A C T O R Y S E T T I N G  
. H D D MO U N T  
1
]
J
. D I R –  
+
1
2
3
4
5
6
7
8
9
.
O F F  
S T D  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
[
-
-
-
-
]
. D I  
. D I  
. D I  
. D I  
. D I  
. D I  
. D I  
P
P
P
P
P
P
P
P
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
0
1
2
3
4
5
6
7
2. Simultaneously press the MENU button and the 4 button while holding down the STOP  
button.  
STD: Normally, use this position. Up to 13,000 alarm/  
sensor events can be recorded.  
The MENU screen is displayed.  
[ M E N U ]  
F U N C T I O N -  
F U N C T I O N -  
J
. D I R  
1 0 . D I  
1
2
EXTN: Set to this position if you want to be able to record  
more than 13,000 alarm/sensor events (up to about  
100,000 events).  
H O U R M E T E R  
E M E R G E N C Y H I S T O R Y  
O P E R A T I O N C H E C K MO D E  
O P E  
H D R  
B O O T  
S C S  
V E R .  
V E R .  
V E R .  
V E R .  
x x  
x x  
x x  
x x  
x x  
.
.
.
.
.
x x  
x x  
x x  
x x  
x x  
* Extended formatting takes about 5 minutes to complete.  
Recording time is shorter than with the standard format.  
I
E X T . M V E R .  
6. Press the ¢ to start mounting.  
3. Make sure FUNCTION-1 is selected and then return the shuttle dial to the SELECT  
During mounting MOUNT XX% is displayed on the monitor.  
Numbers are displayed instead of XX to show the progress.  
When mounting has finished the INPUT SIG ERROR and  
MOUNT ERROR messages are displayed on the monitor  
alternately. After approximately 10 to 20 seconds the  
MOUNT ERROR message disappears and mounting is  
complete.  
3
-
-
1 0  
-
-
0 2 S U N 1 8  
:
0 5  
:
2 1  
position by turning it either clockwise or anticlockwise.  
A L  
-
-
-
-
-
-
-
-
%
The FUNCTION-1 screen is displayed.  
[
F U N C T I O N -  
F A C T O R Y S E T T I N G  
. H D D MO U N T  
1
]
J
. D I R  
1
2
3
4
5
6
7
8
9
.
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
O F F  
MO U N T  
I N P U T  
x x %  
I G E R R O R  
[
-
-
-
-
]
S
. D I  
. D I  
. D I  
. D I  
. D I  
. D I  
. D I  
P
P
P
P
P
P
P
P
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
SW -  
0
1
2
3
4
5
6
7
1 0 . D I  
6
7
How to Verify Mounting  
Specifications  
Mass:  
Approx. 750 g (including stand)  
9 W or less  
The following describes how to operate the front panel of the VR-510U to verify that the SA-  
K51U is mounted.  
Power Consumption:  
Allowable operating temperature:  
Allowable storage temperature:  
Allowable operating humidity:  
Accessories:  
5°C to 40°C  
1. Press the MENU button.  
20°C to 60°C  
The MENU screen is displayed.  
[ M E N U ]  
C L O C K S E T  
J
. D I R  
·
30% to 80% RH  
O N S C R E E N /  
H D R MO D E  
E X T MO D E  
F
. D I S P MO D E  
Stand × 1  
Screw (silver) × 4  
Screw (black) × 4  
A L A R M / S E N S O R MO D E  
B U Z Z E R  
P R O G R A M  
H O R I D A Y S E T  
S Y S T E M / S T  
T
I M E R  
L
I
2. Select SYSTEM/LIST by turning the jog dial and then return the shuttle dial to the SELECT  
position by turning it either clockwise or anticlockwise.  
The SYSTEM/LIST screen is displayed.Verify that 160 GB  
is displayed for the UTILITY item.  
[ S Y S T E M ]  
J O G  
1 6 0 G B ]  
·
U T  
I
L
I
T Y  
[
[
L
I
S T  
]
H O U R M E T E R  
P OWE R L O S S  
/
L
I
S T  
8
9

Motorola m500 User Manual
Hamilton Beach Coffeemaker 48463C User Manual
Hamilton Beach 840049600 User Manual
Hamilton Beach 6 Cup BrewStation 48274 User Manual
GE 840146700 User Manual
FujiFilm DVCPRO DP121 User Manual
Evolution Technologies Coffeemaker PR10908000 User Manual
Emerson Barbie BAR504 User Manual
Cuisinart DTC 850 User Manual
Atlantis Land DISKMASTER NASF101 User Manual