Fujitsu ETERNUS DX80 User Manual

Disk storage system  
P3AM-3102-04EN  
Setup Guide (SAS model)  
Read this Setup Guide first  
This guide describes the workflow required to proceed from installation to  
operation of the  
(SAS model).  
Workflow  
Preparation  
Basic Setup  
1
5
6
7
8
Read and understand the "Safety Precautions"  
before use.  
Installation  
Monitoring Setup  
2
3
4
Cable Connection  
Startup  
Server Connection  
Operation and Maintenance  
"Safety Precautions"  
The company names, product names and service names mentioned in this document are registered trademarks or trademarks of their respective companies.  
Copyright 2010 FUJITSU LIMITED  
The latest version of this document and the latest information about the ETERNUS DX60/DX80 is released in the following web-site. Access the following address if needed.  
S T E P  
Preparation  
Package Contents Check  
Refer to the "Package Contents" and check that there are no missing items.  
Misc. documents  
ETERNUS DX60/DX80  
Prepare the following manuals:  
n
n
n
n
Documentation CD  
"Safety Precautions"  
"Package Contents"  
Other related manuals, for example, for a server or  
networking equipment.  
Misc. cables  
Rack mount kit  
When ETERNUS SF Express is used, prepare the following  
software and User's Guide:  
n
n
ETERNUS SF Express Media Pack  
"ETERNUS SF Express User's Guide"  
"Package Contents"  
Installation and Connection Preparation  
Setup Preparation  
Installation space  
Completing and attaching the Network Settings label  
Check that the installation area meets the space requirements  
Complete the following information in the Network Settings  
label and attach it on the ETERNUS DX60/DX80.  
of the rack in which the ETERNUS DX60/DX80 is to be installed.  
n
IP address and subnet mask for the ETERNUS DX60/  
DX80  
Installation requirements  
Check that the installation area satisfies all the requirements  
described in the "Instructions for installation" section of the  
"Safety Precautions".  
n
IP address for maintenance work  
Settings for the PC  
n
Setup Network Environment  
Environmental conditions  
IP address:  
192.168.1.2  
Temperature: 5 – 40 C, Humidity: 20 – 80%RH  
°
Subnet mask: 255.255.255.0  
Power outlets  
n
Set the Web browser  
Check that a sufficient number of suitable wall outlets are  
available.  
Proxy server and Cache : Disable  
Java Script, style sheets, and cookies : Enable  
"7.1 Setup Preparation" in the "User Guide"  
n
n
n
"5.1 Installation Preparation" in the "User Guide"  
"6.1 Connection Preparation" in the "User Guide"  
"Safety Precautions"  
Proceed to  
next step  
S T E P  
Startup  
Connect the PC to the ETERNUS DX60/DX80 with a LAN cable (for operation management), and turn on the ETERNUS DX60/  
DX80.  
n
n
"7.1 Setup Preparation" in the "User Guide"  
"7.2 Basic Setup" in the "User Guide"  
Power switch  
The first time the power is turned on, volume  
IMPORTANT  
formatting may start according to the factory  
default settings. This does not affect the setup  
operation, which may be started immediately.  
Controller  
Enclosure  
S T E P  
Basic Setup  
Basic ETERNUS DX60/DX80 setup is performed by accessing  
the "Initial Setup" and "Configuration Wizard" functions with a  
Web browser.  
After completing these settings with the Finish step, close  
the web browser to end the setup session, then detach the  
direct connection LAN cable (for operation management)  
from the PC and connect it to the normal network. Then  
try logging on again via the normal network, using the IP  
address that has just been set.  
1. Start the Web browser on the PC and enter either of the  
following URLs in the address bar of the Web browser.  
"7.2.1 Initial Setup" in the "User Guide"  
2. Enter the following user name and password, and click the  
[Logon] button to logon to the ETERNUS DX60/DX80.  
User name: root  
Configuration Wizard  
Password: root (Default)  
Perform the necessary settings to operate the ETERNUS  
DX60/DX80 using the Configuration Wizard.  
3. After logging on, the Storage System Status screen  
appears.  
The [Configuration Wizard] screen appears by clicking the  
[Configuration Wizard] button on the [Easy Setup] tab.  
When ETERNUS SF Express is used, perform  
the following setup, and then refer to the  
"ETERNUS SF Express User's Guide" to install  
the ETERNUS DX Disk storage system.  
Initial Setup  
Point  
Set Date and Time  
Set Storage System Name  
Change Password  
n
n
n
n
Create RAID Group  
Create Volume  
Configure Affinity Group  
Define LUN Mapping  
Setup Network Environment  
n
Define Host  
"7.2.2 Configuration Wizard" in the "User Guide"  
Initial Setup  
Set the necessary environment for operating the ETERNUS  
DX60/DX80 with its initial setup.  
Default RAID groups, volumes and affinity  
groups are preset in the factory. Refer to "Web  
GUI User Guide" if the preset values are to be  
changed.  
Point  
The [Initial Setup] screen appears by clicking the [Initial  
Setup] menu on the [Easy Setup] tab.  
This screen is used to set the following items:  
n
n
n
n
n
Set Date and Time  
Set Storage System Name  
Change Password  
Assigning Hot Spares  
Register hot spares for use in case the regular disks fail.  
The [Assign Hot Spare] screen appears by clicking [Assign  
Hot Spare] under the [RAID Group Management] menu on the  
[Volume Settings] tab.  
Set SAS Port Parameters  
Setup Network Environment  
"7.2.3 Hot Spare Registration" in the "User Guide"  
Check the factory settings and register a hot  
Point  
spare as required.  
S T E P  
Monitoring Setup  
Perform the ETERNUS DX60/DX80 monitoring setup if required.  
n
Notification of ETERNUS DX60/DX80 problems as they occur is possible if the event notification method and level have  
been set.  
n
n
n
For e-mail notification of ETERNUS DX60/DX80 problems, a destination e-mail address must be set.  
If "ServerView" is used to monitor the server, the ETERNUS DX60/DX80 must be set to send an SNMP Trap to the server.  
If remote support is required, the ETERNUS DX60/DX80 must be set to notify the remote support center of failures.  
Remote support allows prompt detection and resolution of trouble.  
Point  
"7.4 Monitoring Setup" in the "User Guide"  
S T E P  
Server Connection  
Various tasks need to be performed before the ETERNUS DX60/DX80 can be connected to the server. These include the  
installation of the appropriate drivers.  
Check which server OS, and/or SAS card are to be connected to before starting this step.  
For details on the setting, refer to "ETERNUS DX Disk storage systems Server Connection Guide (SAS)"(*).  
* :  
Download from the specified web-site in the Documentation CD.  
n
n
"7.5 Server Connection Setup" in the "User Guide"  
"ETERNUS DX Disk storage systems Server Connection Guide (SAS)"  
- for Windows®  
- for Linux  
- for Solaris™ Operating System  
- ETERNUS DX Disk Storage System Settings for ETERNUS DX60/DX80  
- for VMware® ESX  
All necessary settings are complete, and the ETERNUS DX60/DX80 is now ready for normal operation.  
S T E P  
Operation and Maintenance  
Status check  
The status of the ETERNUS DX60/DX80 should be regularly monitored by checking the LEDs and using the Web browser.  
Data backup  
Important data should be regularly backed up to a tape drive or similar device as a precaution against system failures.  
Maintenance support period  
The maintenance support period for the ETERNUS DX60/DX80 is 5 years from the date of purchase.  
ETERNUS DX60/DX80 Disk storage system Setup Guide  
(SAS model)  
P3AM-3102-04EN  
Date of issuance: July 2010  
Issuance responsibility: FUJITSU LIMITED  
Printed in Japan  
The contents of this manual may be updated without notice.  
While the contents of this manual are the product of all due care and  
diligence, no responsibility can be accepted for operational problems  
arising from any errors or missing information, or other use of the  
information contained in this manual.  
Fujitsu assumes no liability for damages to third party copyrights or  
other rights arising from the use of any information in this manual.  
Contents of this manual are not to be reproduced without permission  
from Fujitsu.  
Manuals with missing or wrongly collated pages will be replaced free of  
charge.  
This manual uses recycled paper.  

Maxtor OneTouch 1TB User Manual
Marantz CC4001 User Manual
Kyocera KX444 User Manual
HTC KII0160 User Manual
Hamilton Beach 840154301 User Manual
DeLonghi Coffeemaker EC9 User Manual
Centon electronic DataStick Bolt 2GBDSB RED User Manual
Bunn RWS1A User Manual
Black Box Computer Accessories JPM614A R7 User Manual
Apple Boxlight Projector 9000 User Manual