Bunn TNTF 3 User Manual

®
BUNN  
TNT-3  
TNTF-3  
OPERATING & SERVICE MANUAL  
BUNN-O-MATIC CORPORATION  
POST OFFICE BOX 3227  
SPRINGFIELD, ILLINOIS 62708-3227  
TELEPHONE: (217) 529-6601 FAX: (217) 529-6644  
28201.0000C 8/00 © 1997 Bunn-O-Matic Corporation  
USER NOTICES  
Carefully read and follow all notices on the equipment and in this manual. They were written for your protection.  
All notices on the equipment should be kept in good condition. Replace any unreadable or damaged labels.  
#00831.0000  
#00656.0000  
#03408.0000  
#03409.0000  
28201 081598  
Page 3  
ELECTRICAL REQUIREMENTS  
CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.  
120V model brewers require 2-wire, grounded service rated 120 volt  
ac, 15 amp, single phase, 60 Hz.  
L2 RED  
120/208V model brewers require 3-wire, grounded service rated 120/  
208 volt, 20 amp, single phase, 60 Hz.  
120V.A.C.  
WHITE  
208V.A.C.  
NEUTRAL  
L1 BLACK  
120V.A.C.  
Electrical Hook-Up  
CAUTION Improper electrical installation will damage electronic components.  
1. An electrician must provide electrical service as specified.  
2. Remove the top lid and rotate the control thermostat knob fully counterclockwise to the "OFF" position.  
3. a) 120V brewers have an attached cordset. Plug in the brewer and proceed to #6.  
b) 120/208V brewers, feed the cord through the strain refief at the rear of the brewer and connect it to the  
terminal block.  
4. Using a voltmeter, check the voltage and color coding of each conductor at the power source.  
5. Connect the brewer to the power source and verify the voltage at the terminal block.  
6. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing  
has been hooked up, the brewer is ready for Initial Set-Up.  
PLUMBING REQUIREMENTS  
These brewers must be connected to a cold water system with operating pressure between 20 (138) and 90  
1
psi (620 kPa) from a 2" or larger supply line. A shut-off valve should be installed in the line before the brewer.  
Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The  
1
water inlet fitting is 4" flare.  
1
3
NOTE - Bunn-O-Matic recommends 4" copper tubing for installations of less than 25 feet and 8" for more than  
1
25 feet from the 2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the  
brewer to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the  
brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.  
This equipment must be installed to comply with the Basic Plumbing Code of the  
Building Officials and Code Administrators International, Inc. (BOCA)  
and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).  
28201 081500  
Page 4  
PLUMBING REQUIREMENTS (cont.)  
P1394  
P1392  
BREWERS W/OUT FAUCET  
BREWERS W/FAUCET  
1. Remove the shipping cap(s) from the bulkhead fitting(s) on the rear of the brewer.  
2. Attach the flare fitting from the short piece of tubing on the strainer/flow control (supplied) to the water inlet  
fitting(s) at the rear of the brewer.  
3. Flush the water line and securely attach it to the flare fitting on the tee or strainer/flow control.  
4. Turn on the water supply.  
5. On Brewers with a faucet place an empty vessel beneath the faucet and lift the handle until water is dis-  
pensed.  
INITIAL SET-UP  
CAUTION The brewer must be unplugged throughout the initial set-up, except when specified in the in-  
structions.  
1. Remove the top lid from the brewer.  
2. Rotate the control thermostat knob fully counterclockwise to the OFFposition and replace the top lid.  
3. Insert the funnel (empty) into the funnel rails.  
4. Place an empty tea dispenser on the brewer base. Be prepared to empty the dispenser a few times.  
5. Plug in the brewer, place the ICED/OFF/HOT switch in the HOTposition, and momentarily press the start  
switch. When the flow of water into the tank stops, press the start switch to initiate a second cycle. Wait until  
the flow of water stops and start a third cycle.. During the third cycle, the tank will fill to its capacity and the  
excess will flow from the funnel into the dispenser. Empty the dispenser when this third cycle stops.  
6. Place the ICED/OFF/HOT switch in the ICEDposition and begin another brew cycle.  
7. Measure the total water volume from the dispenser. It should be approximately (396 ounces.)  
8. If not, adjust the Iced Tea timer as required. See Adjusting Brew Volumes.  
9. Start and measure another cycle.  
10. Repeat steps 7-9 until the recommended total water volume (396 ounces) is achieved.  
11. The concentrate valve is preadjusted to deliver the correct ratio of brew water to dilution water.  
12. Unplug the brewer, remove the top lid, rotate the control thermostat knob fully clockwise to the ONposition  
and replace the top lid.  
28201 081500  
Page 5  
INITIAL SET-UP (cont.)  
13. Empty the dispenser.  
14. Plug in the brewer and wait for the water in the tank to heat to brewing temperature (approximately 20  
minutes). Some water will drip from the funnel during this time; this is due to expansion and should not  
occur thereafter.  
15. Place the ICED/OFF/HOT switch in the HOTposition and begin another brew cycle. Empty the reservoir  
after water has stopped flowing from the funnel.  
16. Allow the water in the tank to heat to the proper temperature and begin another brew cycle.  
17. Measure the total water volume from the dispenser. It should be approximately 64 ounces.  
18. If not, adjust the Hot Tea timer as required. See Adjusting Brew Volumes.  
19. Start and measure another cycle.  
20. Repeat steps 17-19 until the recommended total water volume (64 ounces) is achieved.  
21 The brewer is now ready to brew approximately one-half gallon of hot tea or 3-gallons of freshly brewed  
room temperature tea.  
ADJUSTING BREW VOLUMES  
CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement  
or adjustment of any component.  
NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is  
properly filled, and a funnel and server are in place.  
1. Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the SET”  
position on the circuit board.  
To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release the  
switch (Failure to release the switch within two seconds after the third click causes the volume setting to be  
aborted and previous volume setting will remain in memory) and press it again one or more times. Each time  
the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order  
to verify that the desired volume has been achieved.  
To decrease a batch size. Press and release the START or BREW switch once for every two-second interval  
to be removed from the total brew time period; then immediately press and hold down the START or BREW  
switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after  
the third click causes the volume setting to be aborted and previous volume setting will remain in memory).  
Allow the brew cycle to finish in order to verify that the desired volume has been achieved.  
2. Setting batch sizes. To set a batch volume, first check that the SET/LOCK switch is in the SETposition on  
the circuit board. Press and hold the START or BREW switch until three distinct clicks are heard, and then  
release the switch. (Failure to release the switch within two seconds after the third click causes the volume  
setting to be aborted and previous volume setting will remain in memory). View the level of the liquid being  
dispensed. When the desired level is reached, turn the ON/OFF switch to OFF(lower). The brewer remem-  
bers this volume and will continue to brew batches of this size until the volume setting procedure is repeated.  
NOTE: When brewing coffee, batch volumes will decrease due to absorption by the coffee grounds.  
3. Setting programming disable feature. If it becomes necessary to prevent anyone from changing brew times  
once programmed, you can set the SET/LOCK switch to the LOCKposition. This will prevent any program-  
ming to be done until switch is once again placed in the SETposition.  
28201 081500  
Page 6  
CLEANING  
CAUTION Do not keep brewed tea overnight. Clean and sanitize your iced tea dispenser daily  
1. Remove and thoroughly clean the brew funnel. The funnel tip and screen must be free from any tea particles  
or residue. Reassemble the funnel.  
2. Unplug the brewer. Remove and thoroughly rinse the sprayhead. The holes must be open and clear of any  
mineral deposits. Wipe the sprayhead panel clean with a damp cloth.  
3. Insert the deliming spring into the sprayhead fitting until no more than one inch is visible and move it in and  
out 5 or 6 times. Insert the spring into the airvent hole in the sprayhead panel and move it in and out 5 or 6  
times. Reattach the sprayhead.  
4. Wash the entire outside surface of the brewer with a clean damp cloth.  
OPERATING CONTROLS  
A. ICED/OFF/HOT Switch  
ICED Placing the switch in the left position allows the start switch to activate a timed brew cycle delivering  
.5 gallon of tea concentrate and 2.5 gallons of dilution water into the dispenser.  
OFF Placing the switch in the center position stops the brew cycle. Stopping a brew cycle after it has  
started will not stop the flow of water into the funnel until the tank syphons down to its level. The switch should  
always be placed in this position after a brew cycle and whenever the brewer is unattended.  
HOT Placing the switch in the right position allows the start switch to activate a timed brew cycle delivering  
.5 gallon of hot tea into an airpot dispenser.  
B. Start Switch  
Starts a brew cycle when the ICED/OFF/HOT switch is in either the ICEDor HOTposition.  
BREWING  
1. Begin brewing with a clean empty brew funnel and dispenser. (Be sure the dispenser is open.)  
2. Insert a BUNN® filter into the funnel.  
3. Pour the fresh loose tea leaves into the filter.  
4. Level the bed of tea leaves by gently shaking.  
5. Slide the funnel into the funnel rails until it stops.  
6. Place the ICED/OFF/HOT switch in the desired position.  
7. Momentarily press the start switch.  
8. Carefully remove the brew funnel and discard its contents after liquid stops flowing from the funnel.  
CAUTION The funnel contains hot liquid. Remove funnel slowly.  
9. Place the ICED/OFF/HOT switch in the OFFposition to prevent a false start.  
28201 081500  
Page 7  
TROUBLESHOOTING  
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems  
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic  
Technical Service Department.  
Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-  
nel.  
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of  
terminals or the application of external voltages may result in board failure.  
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an  
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a  
terminal or crimp.  
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are  
energized for more than ten minutes without a supply of water.  
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will  
help to avoid twists and kinks in the tubing.  
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.  
This brewer is heated at all times. Keep away from combustibles.  
WARNING –  
Exercise extreme caution when servicing electrical equipment.  
Unplug the brewer when servicing, except when electrical tests are specified.  
Follow recommended service procedures  
Replace all protective shields or safety notices  
Remedy  
Problem  
Probable Cause  
Water lines and valves to the brewer  
must be open.  
Brew cycle(s) will not start  
1. No water  
Check circuit breakers or fuses.  
2. No power or incorrect voltage to  
the brewer  
(A) Direction of flow arrow must be  
pointing towards the brewer.  
3.External Strainer/ Flow Control  
(.750 GPM)  
(B) Remove the strainer/flow con-  
trol and check for obstructions.  
Clear or replace.  
Refer to Service - ICED/OFF/HOT  
Switch for testing. See page 26  
4. ICED/OFF/HOT Switch  
5. Start Switch  
Refer to Service - Start Switch for  
testing procedures. See page 27  
28201 081500  
Page 8  
TROUBLESHOOTING (cont.)  
PROBLEM  
PROBABLE CAUSE  
REMEDY  
6. Brew Timer  
A) Iced Tea  
Brew cycle(s) will not start (cont.)  
Refer to Service - Brew Timer (Iced  
Tea) for testing procedures. See  
page 20 or 21  
B) Hot Tea  
Refer to Service - Brew Timer (Hot  
Tea) for testing procedures. See  
page 17 or 18  
7. Brew Solenoid Valve  
A) Iced Tea  
Refer to Service - Brew Solenoid  
Valve (Iced Tea) for testing proce-  
dures. See page 16  
B) Hot Tea  
Refer to Service- Brew Solenoid  
Valve (Hot Tea) for testing proce-  
dures. See page 15  
8. Internal Flow control (.222 GPM)  
(Hot Tea Only)  
(A) Direction of flow arrow must be  
pointing towards brewer.  
(B) Remove the flow control and  
check for obstructions. Clear or re-  
place.  
1. Limit Thermostat  
CAUTION - Do not eliminate or by-  
pass limit thermostat. Use only  
Brew water is not hot  
Refer to Service - Limit Thermostat  
for testing procedures. See page 25  
BOM  
replacement  
part  
#29329.1000  
2. Thermal Fuse  
CAUTION - Do not eleminate or by-  
pass thermal fuse.  
Refer to Service - Thermal fuse for  
testing procedures. See page 29  
3. Control Thermostat  
Refer to Service - Control Thermo-  
stat for testing procedures. See  
page 23  
4. Tank Heater  
Refer to Service - Tank Heater for  
testing procedures. See page 28  
1. ICED/OFF/HOT Switch  
Dilution (Iced Tea) cycle will not  
start  
Refer to Service - ICED/OFF/HOT  
Switch for testing procedures. See  
page 26  
28201 081500  
Page 9  
TROUBLESHOOTING (cont.)  
PROBLEM  
PROBABLE CAUSE  
REMEDY  
Dilution (Iced Tea) cycle will not 2. Start Switch  
start (cont.)  
Refer to Service - Start Switch for  
testing procedures. See page 27  
3. Brew Timer (Iced Tea)  
Refer to Service- Brew Timer (Iced  
Tea) for testing procedures. See  
page 20 or 21  
4. Brew Solenoid Valve (Iced Tea)  
5. Dilution Solenoid Valve  
Refer to Service - Brew Solenoid  
Valve (Iced Tea) for testing proce-  
dures. See page 16  
Refer to Service - Dilution Solenoid  
Valve for testing procedures. See  
page 24  
Inconsistent beverage level in  
dispenser (Hot Tea)  
1. Internal Flow Control (.222 GPM) (A) Direction of flow arrow must be  
pointing towards the brewer.  
(B) Remove the flow control and  
check for obstruction. Clear or re-  
place.  
2. Syphon System  
3. Lime Build-up  
The brewer must be level or slightly  
lower in front to syphon properly.  
Inspect the tank assembly for ex-  
CAUTION - Tank and tank compo- cessive lime deposits. Delime as  
nents should be delimed regularly required.  
depending on local water condi-  
tions. Excessive mineral build-up  
on stainless steel surfaces can ini-  
tiate corrosive reactions resulting  
in serious leaks.  
4. Water Pressure  
The water pressure to the brewer  
must be at least 20 psi.  
Consistently high or low beverage  
level in the dispenser  
1. Brew Timer  
With the ICED/OFF/HOT switch in  
the "ICED" position adjust the needle  
valve to achieve the recommended  
76 oz of concentrate then the timer  
to achieve a total of 396 oz for each  
three-gallon brew cycle.  
28201 081500  
Page 10  
TROUBLESHOOTING (cont.)  
PROBLEM  
REMEDY  
PROBABLE CAUSE  
Consistently high or low beverage  
level in the dispenser. (cont.)  
(A) Direction of flow arrow must be  
pointing towards brewer.  
2. External Strainer/Flow Control  
(.750 GPM)  
(B) Remove the strainer/flow con-  
trol and check for obstructions.  
Clear or replace.  
Spitting or excessive steaming  
Inspect tank assembly for excessive  
lime deposits. Delime as required.  
1. Lime Build-up  
CAUTION - Tank and tank compo-  
nents should be delimed regularly  
depending on local water condi-  
tions. Excessive mineral build-up  
on stainless steel surfaces can ini-  
tiate corrosive reactions resulting  
in serious leaks.  
Refer to Service - Control Thermo-  
stat for testing procedures. See  
page 23  
2. Control Thermostat  
Drip-out time too long  
The brew funnel should be cleaned  
thoroughly before each brew cycle  
to lessen the chance of tea leaf par-  
ticles clogging the drip-out tip.  
1. Funnel Tip  
Dripping from sprayhead  
The brewer must be level or slightly  
lower in front to syphon properly.  
1. Syphon System  
Inspect the tank assembly for ex-  
cessive lime deposits. Delime as  
required.  
2. Lime Build-up  
CAUTION - Tank and tank compo-  
nents should be delimed regularly  
depending on local water condi-  
tions. Excessive mineral build-up  
on stainless steel surfaces can ini-  
tiate corrosive reactions resulting  
in serious leaks.  
Refer to Service - Brew Solenoid  
Valve (Iced Tea) for testing proce-  
dures. See page 16  
3. Brew Solenoid Valve  
A) Iced Tea  
Refer to Service- Brew Solenoid  
Valve (Hot Tea) for testing proce-  
dures. See Page 15  
B) Hot Tea  
28201 081500  
Page 11  
TROUBLESHOOTING (cont.)  
PROBLEM  
REMEDY  
PROBABLE CAUSE  
Water flows into tank continuously 1. Brew Timer  
Refer to Service - Brew Timer (Iced  
Tea) for testing procedures. See  
page 20  
(ICED/OFF/HOT Switch in the "ICED  
or "HOT" position)  
A) Iced Tea  
Refer to Service- Brew Timer (Hot  
Tea) for testing procedures. See  
page 17  
B) Hot Tea  
Water flows into tank continuously 1. Brew Solenoid Valve  
Refer to Service - Brew Solenoid  
Valve (Iced Tea) for testing proce-  
dures. See page 16  
(ICED/OFF/HOT Switch in the "OFF"  
position)  
A) Iced Tea  
Refer to Service- Brew Solenoid  
Valve (Hot Tea) for testing proce-  
dures. See page 15  
B) Hot Tea  
The dispenser must be completely  
empty before starting a brew cycle.  
Beverage overflows dispenser  
1.Dispenser  
2. Brew Timer  
A) Iced Tea  
Refer to Service - Brew Timer (Iced  
Tea) for testing procedures. See  
page 20 or 21  
Refer to Service- Brew Timer (Hot  
Tea) for testing procedures. See  
page 17 or 18  
B) Hot Tea  
3. Brew Solenoid Valve  
A) Iced Tea  
Remove the Iced Tea Brew Solenoid  
Valve and clean any obstruction.  
Rebuild or replace the valve if nec-  
essary. See page 16  
Remove the Hot Tea Brew Solenoid  
Valve and clean any obstruction.  
Rebuild or replace the valve if nec-  
essary. See page 15  
B) Hot Tea  
4. Dilution Solenoid Valve  
Page 12  
Refer to Service - Dilution Solenoid  
Valve for testing procedures. See  
page 24  
28201 081500  
TROUBLESHOOTING (cont.)  
REMEDY  
PROBLEM  
Weak beverage  
PROBABLE CAUSE  
1. Filter Type  
BUNN® paper filters must be used  
for proper extraction.  
A sufficient quantity of fresh, loose  
tea leaves should be used for proper  
extraction.  
2. Tea  
A six-hole stainless steel spray-  
head must be used for proper ex-  
traction.  
3. Sprayhead  
The BUNN® paper filter must be cen-  
tered in the funnel and the bed of tea  
leaves leveled by gentle shaking.  
4. Funnel Loading  
5. Water Temperature  
Place an empty funnel on an empty  
dispenser beneath the sprayhead. Ini-  
tiate a brew cycle and check the wa-  
ter temperature immediately below  
the sprayhead with a thermometer.  
The reading should not be less than  
200°F (93°C). Adjust the control ther-  
mostat to increase the water tempera-  
ture. Replace if necessary.  
The BUNN® paper filter must be cen-  
tered in the funnel and the bed of  
grounds leveled by gently shaking.  
Dry tea leaves remain in the  
funnel  
1. Funnel Loading  
1. Solenoid(s)  
The nut on the solenoid(s) must be  
tight or it will vibrate during opera-  
tion.  
Brewer is making unusal noises  
Plumbing lines should not be rest-  
ing on the counter top.  
2. Plumbing Lines  
3. Water Supply  
(A) The brewer must be connected  
to a cold water line.  
(B) Water pressure to the brewer  
must not exceed 90 psi (620 kPa).  
Install a regulator if necessary to  
lower the working pressure to ap-  
proximately 50 psi (345 kPa).  
Remove and clean lime off the tank  
4. Tank Heater  
Page 13  
heater. See page 28  
28201 081500  
SERVICE  
This section provides procedures for testing and  
replacing various major components used in this  
brewer should service become necessary. Refer to  
Troubleshooting for assistance in determining the  
cause of any problem.  
WARNING - Inspection, testing, and repair of electri-  
cal equipment should be performed only by qualified  
service personnel. The brewer should be disconnected  
from the power source when servicing, except when  
electrical tests are required and the test procedure spe-  
cifically states to plug in the brewer.  
COMPONENT ACCESS  
WARNING - Disconnect the brewer from the power  
source before the removal of any panel or the replace-  
ment of any component.  
All components are accessible by the removal of  
the top cover and rear inspection panel.  
The top cover is attached with four #6-32 screws.  
Removal of the top cover will allow access to ICED/  
OFF/HOT switch, start switch, brew timers, control  
thermostat, limit thermostat, thermal fuse and tank  
heater.  
P1370.40  
The rear inspection panel is attached with six #8-  
32 screws. Removal of the rear panel will allow access  
to the brew solenoid valves and the dilution solenoid  
valve .222 GPM flow control and check valve.  
FIG. 1 COMPONENT ACCESS  
Contents  
Brew Solenoid Valve (Hot Tea)............................ 15  
Brew Solenoid Valve (Iced Tea) .......................... 16  
Brew Timer (Hot Tea) (Early Models).................. 17  
Digital Brew Timer (Hot Tea )(Late Models)........ 18  
Brew Timer (Iced Tea) (Early Models)................. 20  
Digital Brew Timer (Iced Tea)(Late Models ......... 21  
Control Thermostat............................................. 23  
Dilution Solenoid Valve ....................................... 24  
Limit Thermostat ................................................ 25  
ICED/OFF/HOT Switch......................................... 26  
Start Switch ........................................................ 27  
Tank Heater......................................................... 28  
Thermal Fuse ...................................................... 29  
Wiring Diagrams................................................. 30  
28201 081500  
Page 14  
SERVICE (cont.)  
If continuity is not present as described, replace the  
solenoid valve.  
BREW SOLENOID VALVE (HOT TEA)  
6. Check the hot tea solenoid valve for coil action.  
Connect the brewer to the power source. With  
ICED/OFF/HOT switch in the "HOT" position press  
the start switch and listen carefully in the vicinity  
of the solenoid valve for a "clicking" sound as the  
coil magnet attracts.  
7. Disconnect the brewer from the power source.  
If the sound is heard as described and water will not  
pass through the solenoid valve, there may be a block-  
age in the water line before the solenoid valve or, the  
solenoid valve may require inspection for wear, and  
removal of waterborne particles.  
If the sound is not heard as described, replace the  
solenoid valve.  
P1391.60  
Removal and Replacement:  
FIG. 2 HOT TEA BREW SOLENOID VALVE  
Location:  
Viewing the brewer from the rear, the hot tea brew  
solenoid valve is mounted on the left side of the  
mounting bracket.  
1. Remove all wires from solenoid valves.  
2. Turn off the water supply to the brewer.  
3. Disconnect the water lines to and from the sole-  
noid valves.  
4. Remove the two #8-32 keps nuts holding the  
mounting bracket to the brewer base.  
5. Lift out the bracket.  
6. Remove the two #10-32 slotted-head screws hold-  
ing the hot tea solenoid valve to the mounting  
bracket.  
7. Securely install the new hot tea solenoid valve to  
the mounting bracket.  
Test Procedures:  
1. Disconnect the brewer from the power source.  
2. Disconnect the white/red and white/green wires  
from the hot tea solenoid valve. With the ICED/  
OFF/HOT switch in the "HOT" position press the  
start switch.  
3. With a voltmeter, check the voltage across the  
white/red and white/green wires. Connect the  
brewer to the power source. The indication must  
be 120 volts ac for two wire 120 volt models and  
three wire 120/208 volt models.  
8. Attach the mounting bracket to the brewer base.  
9. Securely fasten the water lines to and from the  
solenoid valves.  
10. Refer to Fig.3 when reconnecting the wires.  
WHI/GRN to Hot Tea  
Timer TL 4  
WHI/RED to Hot Tea Timer TL 1  
4. Disconnect the brewer from the power source.  
WHI/VIO to Dilution Solenoid  
WHI/VIO to Iced Tea Brew Timer TL 1  
WHI/BLU to Iced Tea Timer TL 4  
If voltage is present as described, proceed to #5  
If voltage is not present as described, refer to Wiring  
Diagram and check brewer wiring harness.  
WHI/VIO to Iced Tea  
Brew Timer TL 1  
HOT TEA BREW  
SOLENOID  
5. Check for continuity across the hot tea solenoid  
valve coil terminals.  
ICED TEA BREW  
SOLENOID  
WHI/BLU to Iced  
Tea Timer TL 4  
If continuity is present as described, reconnect the  
white/red and white/green wires from the hot tea brew  
timer.  
DILUTION  
SOLENOID  
P1364  
FIG.3 SOLENOID VALVE TERMINALS  
28201 081598  
Page 15  
SERVICE (cont.)  
If continuity is not present as described, replace the  
solenoid valve.  
BREW SOLENOID VALVE (ICED TEA)  
6. Check the iced tea solenoid valve for coil action.  
Connect the brewer to the power source. With  
ICED/OFF/HOT switch in the "ICED" position press  
the start switch and listen carefully in the vicinity  
of the solenoid valve for a "clicking" sound as the  
coil magnet attracts.  
7. Disconnect the brewer from the power source.  
If the sound is heard as described and water will not  
pass through the solenoid valve, there may be a block-  
age in the water line before the solenoid valve, or the  
solenoid valve may require inspection for wear, and  
removal of waterborne particles.  
If the sound is not heard as described, replace the  
solenoid valve.  
Removal and Replacement:  
P1391.60  
FIG. 4 ICED TEA BREW SOLENOID VALVE  
Location:  
1. Remove all wires from solenoid valves.  
2. Turn off the water supply to the brewer.  
3. Disconnect the water lines to and from the sole-  
noid valves.  
4. Remove the two #8-32 keps nuts holding the  
mounting bracket to the brewer base.  
5. Lift out the bracket.  
6. Remove the two #10-32 slotted-head screws hold-  
ing the iced tea brew solenoid valve to the mount-  
ing bracket.  
7. Securely install the new iced tea brew solenoid  
valve to the mounting bracket.  
Viewingthebrewerfromtherear,theicedteabrew  
solenoid valve is mounted in the center of the mount-  
ing bracket.  
Test Procedures:  
1. Disconnect the brewer from the power source.  
2. Disconnect the white/violet and white/blue wires  
from the iced tea brew solenoid valve. With the  
ICED/OFF/HOT switch in the "ICED" position press  
the start switch.  
3. With a voltmeter, check the voltage across the  
white/violet and white/blue wires. Connect the  
brewer to the power source. The indication must  
be 120 volts ac for two wire 120 volt models and  
three wire 120/208 volt models.  
8. Attach the mounting bracket to the brewer base.  
9. Securely fasten the water lines to and from the  
solenoid valves.  
10. Refer to Fig. 5 when reconnecting the wires.  
WHI/GRN to Hot Tea  
Timer TL 4  
WHI/RED to Hot Tea Timer TL 1  
4. Disconnect the brewer from the power source.  
WHI/VIO to Dilution Solenoid  
WHI/VIO to Iced Tea Brew Timer TL 1  
WHI/BLU to Iced Tea Timer TL 4  
If voltage is present as described, proceed to #5  
If voltage is not present as described, refer to Wiring  
Diagram and check brewer wiring harness.  
WHI/VIO to Iced Tea  
Brew Timer TL 1  
HOT TEA BREW  
SOLENOID  
5. Check for continuity across the iced tea brew so-  
lenoid valve coil terminals.  
ICED TEA BREW  
SOLENOID  
WHI/BLU to Iced  
Tea Timer TL 4  
If continuity is present as described, reconnect the  
white/violet and white/blue wires from the iced tea  
brew timer.  
DILUTION  
SOLENOID  
P1364  
FIG.5 SOLENOID VALVE TERMINALS  
28201 081598  
Page 16  
SERVICE (cont.)  
If continuity is not present as described, refer to the  
Wiring Diagram and check the wiring harness.  
BREW TIMER (HOT TEA - EARLY MODELS)  
5. Check the voltage across terminals TL1 and TL4  
with a voltmeter when the ICED/OFF/HOT switch  
is in the HOTposition and the start switch is  
momentarily placed in the lower position. Con-  
nect the brewer to the power source. The indica-  
tion must be 120 volts ac for two wire 120 volt  
models and three wire 120/208 volt models for  
approximately twenty seconds and then return to  
its previous indication.  
6. Disconnect the brewer from the power source.  
If voltage is present as described, the timer is operat-  
ing properly. Adjust the timer dial as required.  
If voltage is not present as described, replace the timer.  
Removal and Replacement:  
OLD STYLE  
1. Remove all wires from the timer.  
2. Remove the circuit board and dial plate from the  
brackets.  
3. Install the new timer circuit board as described in  
Late Model Timer section on the following pages.  
4. Refer to Fig.9 when reconnecting the wires.  
5. Install the Timer Setting Decal, provided with the  
timer replacement kit, on the bottom of the hood  
cover.  
P1391.60  
FIG. 6 HOT TEA BREW TIMER  
Location:  
Thehotteabrewtimerislocatedinthehoodonthe  
left side. It consists of a dial plate and circuit board.  
Test Procedure:  
1. Disconnect the brewer from the power source.  
2. Remove the wires from terminals TL3, TL4, & TL5  
of the timer and rotate the dial fully counterclock-  
wise.  
2. With a voltmeter, check the voltage across termi-  
nals TL1 and TL2 when the ICED/OFF/HOT switch  
is in the HOTposition. Connect the brewer to  
the power source. The indication must be 120  
volts ac for two wire 120 volt models and three  
wire 120/208 volt models.  
6. Adjust the timer as required. See Late Model Timer  
Section on the following pages.  
WHI to Power Cord (120V Models)  
or WHI to Terminal Block 120/208V  
Models)  
WHI/RED to Hot Tea Brew Solenoid  
WHI/RED to ICED/OFF/HOT Switch  
3. Disconnect the brewer from the power source.  
WHI/ORN to Start Switch  
WHI/GRN to Hot Tea Brew  
Solenoid  
If voltage is present as described, proceed to #4.  
If voltage is not present as described, refer to the Wir-  
ing Diagram and check the wiring harness.  
WHI/YEL to Start Switch  
4. Check for continuity across the white/orange and  
white/yellow wires when the start switch is held  
in the lower position.  
OLD STYLE  
P1365.85  
FIG. 7 HOT TEA BREW TIMER TERMINALS  
If continuity is present as described, reconnect the  
wires to terminals TL3, TL4, & TL5 of the timer board  
and proceed to #5.  
28201 081500  
Page 17  
SERVICE (cont.)  
BREW TIMER (HOT TEA - LATE MODELS)  
6. With a voltmeter, check the voltage across termi-  
nals TL1 and TL4 when the "ON/OFF" switch is in  
the "ON" position and the ICED/OFF/HOT switch is  
in the "HOT" position. Connect the brewer to the  
power source. The indication must be 0 volts.  
If voltage is as described, proceed to #7.  
If voltage is not as described, disconnect the brewer  
from the power source and replace the timer.  
7. With a voltmeter, check the voltage across termi-  
nals TL1 and TL4 when the "ON/OFF" switch is in  
the "ON" position and the ICED/OFF/HOT switch is  
in the "HOT" position. Connect the brewer to the  
power source and press the "START" switch. The  
indication must be 120 volts ac for two wire 120  
volt models and three wire 120/208 volt models.  
NEW STYLE  
If voltage is present as described, the brew timer is  
operating properly. Reset the timer as required, to  
obtain the desired brew volume.  
If voltage is not present as described, disconnect the  
brewer from the power source and replace the timer.  
P2213.60  
FIG. 8 DIGITAL HOT TEA BREW TIMER  
Location:  
The hot tea brew timer is located in the hood, on  
the left side.  
Removal and Replacement:  
1. Remove the two #8-32 screws securing circuit  
board to the mounting bracket.  
2. Remove circuit board and spacers (as required).  
3. Remove all wires from the timer.  
4. Attach all wires to the replacement timer board  
prior to installation to the component mounting  
bracket. Refer to FIG. 9 when reconnecting the  
wires.  
Test Procedure.  
NOTE:Donotremoveorinstallwireswhiletimerboard  
is installed. Pressure applied to one side may cause  
damage to the board.  
1. Disconnect the brewer from the power source and  
remove hood cover.  
2. Remove the two #8-32 screws securing circuit  
board to the mounting bracket.  
3. Remove circuit board and spacers (as required).  
4. With a voltmeter, check the voltage across termi-  
nals TL1 and TL2 when the "ON/OFF" switch is in  
the "ON" position and the ICED/OFF/HOT switch is  
in the "HOT" position. Connect the brewer to the  
power source. The indication must be 120 volts ac  
for two wire 120 volt models and three wire 120/  
208 volt models.  
5. Install new circuit board with spacers (as re-  
quired) to the component mounting bracket.  
6. Adjust the timer as described below.  
Timer Setting:  
NOTE: Prior to setting or modifying volumes, check  
that the brewer is connected to water supply, the tank  
is properly filled, and a funnel and server are in place.  
NOTE: All volume settings must be done with the  
sprayhead installed.  
5. Disconnect the brewer from the power source.  
If voltage is present as described, proceed to #6.  
If voltage is not present as described, refer to the  
Wiring Diagram and check the brewer wiring harness.  
28201 081500  
Page 18  
SERVICE (cont.)  
procedure is repeated.  
BREW TIMER (HOT TEA - LATE MODELS)(cont.)  
NOTE: When brewing coffee, volume will decrease due  
to absorption by the coffee grounds.  
1. Modifying brew volumes. To modify a brew vol-  
ume, first check that the SET/LOCK switch is in the  
SETposition on the circuit board.  
3. Setting programming disable feature. If it be-  
comes necessary to prevent anyone from changing  
brew time once programmed, you can set the SET/  
LOCK switch to the LOCKposition. This will pre-  
vent any further programming until switch is once  
again put into the SETposition.  
To increase a brew volume, place the ON/OFF  
switch in the ONposition, press and hold the START  
switch until three clicks are heard. Release the switch  
and press it again one or more times. (Failure to re-  
lease the switch within two seconds after the third  
click causes the volume setting to be aborted and pre-  
vious volume setting will remain in memory.) Each  
time the switch is pressed, two seconds are added to  
the brew time period. Allow the brew cycle to finish in  
order to verify that the desired volume has been  
achieved.  
To decrease a brew volume, place the ON/OFF  
switch in the ONposition, press and release the  
START switch once for every two-second interval to  
be removed from the total brew time period; then im-  
mediately press and hold down the START switch until  
three clicks are heard. Release the switch. (Failure to  
release the switch within two seconds after the third  
click causes the volume setting to be aborted and pre-  
vious volume setting will remain in memory). Allow  
the brew cycle to finish in order to verify that the de-  
sired volume has been achieved.  
2. Setting brew volumes. To set a brew volume,  
first check that the SET/LOCK switch is in the SET”  
position on the circuit board. Place the ON/OFF switch  
in the ONposition, press and hold the START switch  
until three distinct clicks are heard and then release  
the switch. (Failure to release the switch within two  
seconds after the third click causes the volume set-  
ting to be aborted and previous volume setting will  
remain in memory.)  
TL1 - WHI/RED to Hot Tea Brew Solenoid and  
WHI/RED to ICED/OFF/HOT Switch  
TL2 - WHI to Power Cord (120V Models) or  
WHI to Terminal Block (120/208V Models)  
TL3 - WHI/ORN to Start Switch  
TL4 - WHI/GRN to Hot Tea Brew Solenoid  
TL5 - WHI/YEL to Start Switch  
P2037  
View the level of the liquid being dispensed. When  
the desired level is reached, turn the ON/OFF switch  
to OFF.  
FIG. 9 DIGITAL TIMER WIRING  
NOTE: Several ounces of water will continue to sy-  
phon from the tank after turning the switch OFF.  
The brewer remembers this volume and will continue  
to brew batches of this size until the volume setting  
28201 081500  
Page 19  
SERVICE (cont.)  
If continuity is present as described, reconnect the  
wires to terminals TL3, TL4, & TL5 of the timer board  
and proceed to #5.  
BREW TIMER (ICED TEA - EARLY MODELS)  
If continuity is not present as described, refer to the  
Wiring Diagram and check the wiring harness.  
5. With a voltmeter, check the voltage across termi-  
nals TL1 and TL4 when the ICED/OFF/HOT switch  
is in the ICEDposition and the start switch is  
momentarily placed in the lower position. Con-  
nect the brewer to the power source. The indica-  
tion must be 120 volts ac for two wire 120 volt  
models and three wire 120/208 volt models for  
approximately twenty seconds and then return to  
its previous indication.  
6. Disconnect the brewer from the power source.  
If voltage is present as described, the timer is operat-  
ing properly. Adjust the timer dial as required.  
If voltage is not present as described, replace the timer.  
OLD STYLE  
P1391.60  
FIG. 10 ICED TEA BREW TIMER  
Location:  
Removal and Replacement:  
1. Remove all wires from the iced tea brew timer.  
2. Remove the circuit board and dial plate from the  
brackets.  
3. Install the new timer circuit board as described in  
Late Model Timer section on the following pages.  
4. Refer to Fig. 13 when reconnecting the wires.  
5. Install the Timer Setting Decal, provided with the  
timer replacement kit, on the bottom of the hood  
cover.  
The iced tea brew timer is located in the hood on  
the right side. It consists of the dial plate and circuit  
board.  
Test Procedure:  
1. Disconnect the brewer from the power source.  
2. Remove the wires from terminals TL3, TL4, & TL5  
of the iced tea timer and rotate the dial fully coun-  
terclockwise.  
2. With a voltmeter, check the voltage across termi-  
nals TL1 and TL2 when the ICED/OFF/HOT switch  
is in the ICEDposition. Connect the brewer to  
the power source. The indication must be 120  
volts ac for two wire 120 volt models and three  
wire 120/208 volt models.  
6. Adjust the timer as required. See Late Model Timer  
Section on the following pages.  
WHI to Power Cord (120V Models)  
or WHI to Terminal Block 120/208V  
Models)  
WHI/RED to Hot Tea Brew Solenoid  
WHI/RED to ICED/OFF/HOT Switch  
3. Disconnect the brewer from the power source.  
If voltage is present as described, proceed to #4.  
If voltage is not present as described, refer to the Wir-  
ing Diagram and check the wiring harness.  
ORN to Start Switch  
WHI/BLU to Iced Tea  
Brew Solenoid  
YEL to Start Switch  
4. Check for continuity across the orange and yel-  
low wires when the start switch is held in the lower  
position.  
OLD STYLE  
P1365.85  
FIG. 11 ICED TEA BREW TIMER TERMINALS  
28201 081500  
Page 20  
SERVICE (cont.)  
BREW TIMER (ICED TEA - LATE MODELS)  
6. With a voltmeter, check the voltage across termi-  
nals TL1 and TL4 when the "ON/OFF" switch is in  
the "ON" position and the ICED/OFF/HOT switch is  
in the "ICED" position. Connect the brewer to the  
power source. The indication must be 0 volts.  
If voltage is as described, proceed to #7.  
If voltage is not as described, disconnect the brewer  
from the power source and replace the timer.  
7. With a voltmeter, check the voltage across termi-  
nals TL1 and TL4 when the "ON/OFF" switch is in  
the "ON" position and the ICED/OFF/HOT switch is  
in the "ICED" position. Connect the brewer to the  
power source and press the "START" switch. The  
indication must be as follows 120 volts ac for two  
wire 120 volt models and three wire 120/208 volt  
models.  
NEW STYLE  
P2213.60  
FIG. 12 ICED TEA BREW TIMER  
Location:  
If voltage is present as described, the brew timer is  
operating properly. Reset the timer as required, to  
obtain the desired brew volume.  
The timer is located in the hood on the right side.  
If voltage is not present as described, disconnect the  
brewer from the power source and replace the timer.  
Test Procedure.  
NOTE: Do not remove or install wires while timer  
board is installed. Pressure applied to one side may  
cause damage to the board.  
1. Disconnectthebrewerfromthepowersourceand  
remove the front access panel.  
2. Remove the two #8-32 screws securing circuit  
board to the mounting bracket.  
3. Remove circuit board and spacers (as required).  
4. With a voltmeter, check the voltage across termi-  
nals TL1 and TL2 when the "ON/OFF" switch is in  
the "ON" position and the ICED/OFF/HOT switch is  
in the "ICED" position. Connect the brewer to the  
powersource. Theindicationmustbe120voltsac  
for two wire 120 volt models and three wire 120/  
208 volt models.  
Removal and Replacement:  
1. Remove the two #8-32 screws securing circuit  
board to the mounting bracket.  
2. Remove circuit board and spacers (as required).  
3. Remove all wires from the timer.  
4. Attach all wires to the replacement timer board  
prior to installation to the component mounting  
bracket. Refer to FIG. 13 when reconnecting the  
wires.  
5. Install new circuit board with spacers (as re-  
quired) to the component mounting bracket.  
6. Adjust the timer as described below.  
Timer Setting:  
5. Disconnect the brewer from the power source.  
NOTE: Prior to setting or modifying volumes, check  
that the brewer is connected to water supply, the tank  
is properly filled, and a funnel and server are in place.  
NOTE: All volume settings must be done with the  
sprayhead installed.  
If voltage is present as described, proceed to #6.  
If voltage is not present as described, refer to the  
Wiring Diagrams and check the brewer wiring har-  
ness.  
28201 081500  
Page 21  
SERVICE (cont.)  
BREW TIMER (ICED TEA - LATE MODELS)(cont.)  
1. Modifying brew volumes. To modify a brew vol-  
ume, first check that the SET/LOCK switch is in the  
SETposition on the circuit board.  
NOTE: When brewing coffee, volume will decrease due  
to absorption by the coffee grounds.  
3. Setting programming disable feature. If it be-  
comes necessary to prevent anyone from changing  
brew time once programmed, you can set the SET/  
LOCK switch to the LOCKposition. This will pre-  
vent any further programming until switch is once  
again put into the SETposition.  
To increase a brew volume, place the ON/OFF  
switch in the ONposition, press and hold the START  
switch until three clicks are heard. Release the switch  
and press it again one or more times. (Failure to re-  
lease the switch within two seconds after the third  
click causes the volume setting to be aborted and pre-  
vious volume setting will remain in memory.) Each  
time the switch is pressed, two seconds are added to  
the brew time period. Allow the brew cycle to finish in  
order to verify that the desired volume has been  
achieved.  
To decrease a brew volume, place the ON/OFF  
switch in the ONposition, press and release the  
START switch once for every two-second interval to  
be removed from the total brew time period; then im-  
mediately press and hold down the START switch until  
three clicks are heard. Release the switch. (Failure to  
release the switch within two seconds after the third  
click causes the volume setting to be aborted and pre-  
vious volume setting will remain in memory). Allow  
the brew cycle to finish in order to verify that the de-  
sired volume has been achieved.  
2. Setting brew volumes. To set a brew volume,  
first check that the SET/LOCK switch is in the SET”  
position on the circuit board. Place the ON/OFF switch  
in the ONposition, press and hold the START switch  
until three distinct clicks are heard and then release  
the switch. (Failure to release the switch within two  
seconds after the third click causes the volume set-  
ting to be aborted and previous volume setting will  
remain in memory.)  
TL1 - WHI/VIO to Iced Tea Brew Solennoid and  
WHI/VIO to ICED/OFF/HOT Switch  
TL2 - WHI to Power Cord (120V Models) or  
WHI to Terminal Block (120/208V Models)  
TL3 - ORN to Start Switch  
TL4 - WHI/BLU to Iced Tea Brew Solenoid  
TL5 - YEL to Start Switch  
View the level of the liquid being dispensed. When  
the desired level is reached, turn the ON/OFF switch  
to OFF.  
NOTE: Several ounces of water will continue to sy-  
phon from the tank after turning the switch OFF.  
The brewer remembers this volume and will continue  
to brew batches of this size until the volume setting  
procedure is repeated.  
P2037  
FIG. 13 DIGITAL TIMER WIRING  
28201 081500  
Page 22  
SERVICE (cont.)  
b) 208 volts ac for three wire 120/208 volt mod-  
els  
8. Disconnect the brewer from the power source.  
CONTROL THERMOSTAT  
If voltage is present as described, reinstall the capil-  
lary tube into the tank to the line 4.5" above the bulb,  
the control thermostat is operating properly.  
If voltage is not present as described, replace the ther-  
mostat.  
Removal and Replacement:  
1. Remove both wires from the control thermostat  
terminals.  
2. Remove the thermostat capillary bulb by firmly  
pulling up on the capillary tube at the tank lid. This  
will disengage the grommet from the tank lid.  
3. Remove the #8-32 screw holding the control ther-  
mostat to its bracket.  
4. Slide the grommet to the line 4.5" above the bulb  
on the new capillary tube.  
P2213.60  
FIG. 14 CONTROL THERMOSTAT  
Location:  
The control thermostat is located inside hood on  
the right side just behind the iced tea brew timer.  
5. Insert the capillary bulb through the hole in the  
tank lid and press the grommet firmly and evenly  
so that the groove in the grommet fits into the  
tank lid.  
6. Carefully bend the capillary tube so that the tube  
and bulb inside the tank are in a vertical position.  
Test Procedures:  
1. Disconnect the brewer from the power source.  
2. With a voltmeter, check the voltage across the blue  
wire on the control thermostat and the white wire  
on the tank heater for 120 volt two wire models or  
red wire on the tank heater for 120/208 volt three  
wire models. Connect the brewer to the power  
source. The indication must be:  
NOTE The capillary tube must be clear of any elec-  
trical termination and not kinked.  
7. Fasten the new control thermostat to its bracket.  
8. Refer to Fig. 15 when reconnecting the wires.  
9. Adjust the control thermostat as required.  
a) 120 volts ac for two wire 120 volt models.  
b) 208 volts ac for three wire 120/208 volt mod-  
els.  
3. Disconnect the brewer from the power source.  
If voltage is present as described, proceed to #4.  
If voltage is not present as described, refer to the  
Wiring Diagram and check the brewer wiring harness.  
I
H
O F F  
N
N
HI  
U
B
O F F  
B U N N  
4. Locate the black wire on the control thermostat.  
5. Gently remove the capillary bulb and grommet  
from the tank.  
6. With a voltmeter, check the voltage across the  
black wire of the control thermostat and the white  
wire on the tank heater for 120 volt two wire mod-  
els or red wire on the tank heater for 120/208 volt  
three wire models when the control thermostat is  
turned fully clockwise. Connect the brewer to the  
power source. The indication must be:  
BLK to Tank Heater or  
Thermal Fuse on Models  
W/Faucet  
BLU to Limit Thermostat  
P1390  
FIG. 15 CONTROL THERMOSTAT TERMINALS  
a) 120 volts ac for two wire 120 volt models.  
28201 081598  
Page 23  
SERVICE (cont.)  
5. Check the solenoid valve for coil action. Connect  
the brewer to the power source, place the ICED/  
OFF/HOT switch in the ICEDposition and mo-  
mentarily place the start switch in the lower posi-  
tion and release. Listen carefully in the vicinity of  
the solenoid valve for a clickingsound as the  
coil magnet attracts.  
DILUTION SOLENOID VALVE  
6. Disconnect the brewer from the power source.  
If the sound is heard as described and water will not  
pass through the solenoid valve, there may be a block-  
age in the water line before or after the solenoid valve  
or, the solenoid valve may require inspection for wear,  
and removal of waterborne particles.  
If the sound is not heard as described, replace the  
solenoid valve.  
Removal and Replacement:  
1. Remove all wires from the solenoid valves.  
2. Turn off the water supply to the brewer.  
3. Disconnect the water lines to and from the sole-  
noid valves.  
4. Remove the two #8-32 keps nuts holding the  
mounting bracket to the trunk base.  
P1391.60  
FIG. 16 DILUTION SOLENOID VALVE  
Location:  
Viewing the brewer from the rear the dilution so-  
lenoid is mounted on the right side of the solenoid  
mounting bracket which is secured to the trunk base.  
5. Lift out the bracket.  
6. Remove the two #10-32 slotted-head screws hold-  
ing the solenoid valve to the mounting bracket.  
7. Securely install the new solenoid valve to the  
mounting bracket.  
8. Attach the mounting bracket to the trunk base.  
9. Securely fasten the water lines to and from the  
solenoid valves.  
Test Procedure:  
1. Disconnect the brewer from the power source.  
2. With a voltmeter, check the voltage across the  
white/blue and white/violet wires on the dilution  
solenoid terminals when the ICED/OFF/HOT switch  
is in the ICEDposition and the start switch is  
momentarily placed in the lower position. Con-  
nect the brewer to the power source. The indica-  
tion must be 120 volts ac for two wire 120 volt  
models and three wire 120/208 volt models.  
3. Disconnect the brewer from the power supply.  
10. Refer to Fig. 17 when reconnecting the wires.  
WHI/GRN to Hot Tea  
Timer TL 4  
WHI/RED to Hot Tea Timer TL 1  
WHI/VIO to Dilution Solenoid  
If voltage is present as described, proceed to #4.  
If voltage is not present as described, refer to the Wir-  
ing Diagram and check the wiring harness.  
WHI/VIO to Iced Tea Brew Timer TL 1  
WHI/BLU to Iced Tea Timer TL 4  
WHI/VIO to Iced Tea  
Brew Timer TL 1  
4. Remove both wires from the coil and check for  
continuity across the coil terminals.  
HOT TEA BREW  
SOLENOID  
ICED TEA BREW  
SOLENOID  
If continuity is present as described, reconnect the  
white/blue and white/violet wires and proceed to #5.  
If continuity is not present as described, replace the  
solenoid valve.  
WHI/BLU to Iced  
Tea Timer TL 4  
DILUTION  
SOLENOID  
P1364  
FIG.17 SOLENOID VALVE TERMINALS  
28201 081598  
Page 24  
SERVICE (cont.)  
5. With a voltmeter, check the voltage across the ex-  
posed terminal of the limit thermostat and the  
white wire from the power cord or the red wire  
from the terminal block. Connect the brewer to  
the power source. The indication must be:  
a) 120 volts ac for two wire 120 volt models.  
b) 208 volts ac for three wire 120/208 volt mod-  
els.  
LIMIT THERMOSTAT  
6. Disconnect the brewer from the power source.  
If voltage is present as described, reconnect the blue  
wire to the limit thermostat. The limit thermostat is  
operating properly.  
If voltage is not present as described, replace the limit  
thermostat.  
Removal and Replacement  
1. Remove both wires from the limit thermostat ter-  
minals.  
2. Carefully slide the limit thermostat out from un-  
der the retaining clip.  
3. Carefully slide the new limit thermostat into the  
retaining clip.  
P2213.60  
FIG. 18 LIMIT THERMOSTAT  
Location:  
The limit thermostat is located inside the hood on  
the tank lid.  
4. Refer to Fig. 19 when reconnecting the wires.  
Test Procedure:  
BLU to  
1. Disconnect the brewer from the power source and  
remove the black wire from the limit thermostat.  
2. With a voltmeter, check the voltage across the  
black wire removed from the limit thermostat and  
the white wire or red wire on the tank heater ter-  
minal. Connect the brewer to the power source.  
The indication must be:  
Control  
Thermostat  
a) 120 volts ac for two wire 120 volt models.  
b) 208 volts ac for three wire 120/208 volt mod-  
els.  
BLK to Power Cord  
or Terminal Block  
3. Disconnect the brewer to from the power source.  
P1800  
FIG. 19 LIMIT THERMOSTAT TERMINALS  
If voltage is present as described, reconnect the black  
wire and proceed to #4.  
If voltage is not present as described, refer to the Wir-  
ing Diagram and check the wiring harness.  
4. Remove the blue wire from the limit thermostat.  
28201 081598  
Page 25  
SERVICE (cont.)  
If voltage is present as described, proceed to #6.  
If voltage is not present as described, refer to the Wir-  
ing Diagram and check the wiring harness.  
ICED/OFF/HOT SWITCH  
6. Check for continuity across the center and left ter-  
minals of the top row when switch is in the "ICED"  
position and the center and right terminals of the  
top row when the switch is in the "HOTposition.  
If continuity is present as described, replace the wires,  
the switch is operating properly.  
If continuity is not present as described, replace the  
switch.  
Removal and Replacement:  
1. Remove the wires from the switch terminals.  
2. Compress the clips inside the hood and gently  
push the switch through the opening.  
3. Push the new switch into the opening and spread  
the clips to hold the switch captive in the hood.  
4. Refer to FIG. 21 when reconnecting the wires.  
BLK to Limit Thermostat (120V  
or 120/208V Models)  
WHI/VIO to Iced Tea  
Brew Timer TL1  
WHI/RED to Hot Tea  
Brew Timer TL1  
P1370.40  
FIG. 20 ICED/OFF/HOT SWITCH  
Location:  
The ICED/OFF/HOT switch is located in the front  
of the hood, above and to the left of the brew funnel.  
WHI to Iced Tea Brew Timer TL2  
(120V or 120/208V Models)  
Test Procedure:  
P1367  
1. Disconnect the brewer from the power source.  
2. Remove the black and white/violet wires from the  
switch terminals.  
FIG.21 ICED/OFF/HOT SWITCH TERMINALS  
3. With a voltmeter, check the voltage across the  
black wire removed from the ICED/OFF/HOT switch  
and the white wire remaining on the switch termi-  
nal.  
4. Connect the brewer to the power source.The indi-  
cation must be 120 volts ac for two wire 120 volt  
models and three wire 120/208 volt models,  
5. Disconnect the brewer from the power source.  
28201 081598  
Page 26  
SERVICE (cont.)  
START SWITCH  
4. Check for continuity across the two terminals on  
the left side of the switch when it is held in the  
lower position. Continuity must not be present  
across these terminals in the upper position.  
If continuity is present as described, reconnect the  
wires, the switch is operating properly.  
If continuity is not present as described, replace the  
switch.  
Removal and Replacement:  
1. Remove the wires from the switch terminals.  
2. Compress the clips inside the hood and gently  
push the switch through the opening.  
3. Push the new switch into the opening and spread  
the clips to hold the switch captive in the hood.  
4. Refer to Fig. 23 when reconnecting the wires.  
WHI/ORN to Hot  
Tea Brew Timer TL3  
ORN to Iced Tea  
Brew Timer TL3  
WHI/YEL to  
Hot Tea Brew  
Timer TL5  
YEL to Iced Tea  
Brew Timer TL5  
P1370.40  
P1368  
FIG. 22 START SWITCH  
FIG. 23 START SWITCH TERMINALS  
Location:  
The start switch is located in the front of the hood,  
above and to the right of the brew funnel.  
Test Procedure:  
1. Disconnect the brewer from the power source.  
2. Remove the wires from all four terminals.  
3. Check for continuity across the two terminals on  
the right side of the switch when it is held in the  
lower position. Continuity must not be present  
across these terminals in the upper position.  
If continuity is present as described, proceed to #4.  
If continuity is not present as described, replace the  
switch.  
28201 081598  
Page 27  
SERVICE (cont.)  
TANK HEATER  
Removal and Replacement:  
1. Disconnect the black wire and the white or red  
wire from the tank heater terminals.  
2. Remove sprayhead and the hex nut securing the  
sprayhead tube to the hood. Set aside for reas-  
sembly.  
3. Disconnect vent tube.  
4. Remove the six #10 thread cutting screws secur-  
ing the tank lid to the tank.  
5. Remove the tank lid with limit thermostat, spray-  
head tube, tank heater and vent tube.  
6. Remove the two hex nuts securing the tank heater  
to the tank lid. Remove tank heater with gaskets  
and discard.  
7. Install new tank heater with gaskets on the tank  
lid and secure with two hex nuts.  
P2213.60  
8. Install tank lid with limit thermostat, sprayhead  
tube, tank heater and vent tube using six #10  
thread cutting screws.  
9. Secure sprayhead tube to hood using a hex nut.  
10. Install sprayhead.  
FIG. 24 TANK HEATER  
Location:  
The tank heater is located inside the tank and se-  
cured to the tank lid.  
11. Connect vent tube to fitting.  
Test Procedures:  
12. Reconnect the wires to the limit thermostat and  
tank heater. See limit thermostat section in this  
manual when reconnecting wires.  
13. Refer to Fig.25 when reconnecting the tank heater  
wires.  
1. Disconnect the brewer from the power supply.  
2. With a voltmeter, check the voltage across the  
black and white wires on 120 volt models or the  
black and red wires for 120/208 volt models with  
a voltmeter. Connect the brew to the power source.  
The indication must be:  
WHI to Power Cord (120V Models)  
a) 120 volts ac for two wire 120 volt models .  
b) 208 volts ac for three wire120/208 volt mod-  
els.  
RED to Terminal Block (120/208V  
BLK to Control  
Models)  
Thermostat or  
Thermal Fuse  
3. Disconnect the brewer from the power source.  
If voltage is present as described, proceed to #4  
If voltage is not present as described, refer to the Wir-  
ing Diagrams and check wiring harness.  
4. Disconnect the black wire and the white wire or  
red wire from the tank heater terminals.  
5. Check for continuity across the tank heater termi-  
nals.  
If continuity is present as described, reconnect the  
wires, the tank heater is operating properly.  
If continuity is not present as described, replace the  
tank heater.  
P1369  
FIG. 25 TANK HEATER TERMINALS  
NOTE- If the tank heater remains unable to heat, re-  
move and inspect heater for cracks in the sheath.  
28201 081598  
Page 28  
SERVICE (cont.)  
THERMAL FUSE (Models W/Faucet Only)  
Removal and Replacement:  
1. Disconnect the thermal fuse from the right tank  
heater terminal and the black lead from the con-  
trol thermostat.  
2. Remove thermal fuse and discard.  
3. Connect new thermal fuse to the right tank heater  
terminal and the blaclead from the control ther-  
mostat  
4. Refer to Fig. 27 when reconnecting wires.  
BLK Lead from  
Control Thermostat  
Thermal Fuse  
P2213.60  
FIG. 26 THERMAL FUSE  
Location:  
I
F
H
F
O
N
N
U
B
The thermal fuse is located inside the hood con-  
nected to the right tank heater terminal.  
Tank Heater  
Terminals  
Test Procedures:  
1. Disconnect the brewer from the power source.  
2. Disconnect the thermal fuse from the right tank  
heater terminal and the black lead from the con-  
trol thermostat.  
FIG. 27 THERMAL FUSE THERMINALS P1393.70  
3. With an ohmmeter, check for continuity across  
the thermal fuse terminals.  
If continuity is present as described, the thermal fuse  
is operating properly.  
If continuity is not present as described, replace the  
thermal fuse.  
28201 081598  
Page 29  
28201 081598  
Page 30  

Nokia 1209 User Manual
Mr Coffee ES10 User Manual
Microsoft Software Office Home And Student 2013 79G03550 User Manual
Manhattan Computer Products 451109 User Manual
JVC KD SX838R User Manual
Grindmaster SHUTTLE BREWER APB 430V2E230 User Manual
Clarion DB255 User Manual
American Audio DCD PRO 250 User Manual
Aiwa XR M35 User Manual
Addonics Technologies AD25CFD User Manual