Addonics Technologies Computer Drive R14HPCCES User Manual

T E C H N O L O G I E S  
1U RAID Rack with HPM,  
AES 256-bit encryption  
(R14HPCCES)  
v6.1.11  
Technical Support  
If you need any assistance to get your unit functioning properly, please have your  
product information ready and contact Addonics Technical Support at:  
Hours: 8:30 am - 6:00 pm PST  
Phone: 408-453-6212  
Cipher Chain Module  
The Cipher hardware in the R14CCES is activated by either powering up the  
unit or pressing the Cipher Reset button with the Cipher Key inserted. Without  
activating the Cipher hardware, no drives in the Raid Rack will be visible to the  
computer. Once the Cipher hardware is activated, the amber Cipher LED will  
glow and the drives will be available, and the Cipher key may be removed. If  
the Raid Rack is powered down or the Cipher Reset button is pressed, the key  
will need to be reinserted and the Raid Rack powered up or the reset button  
pressed while the key is inserted for the unit to resume normal operation. All  
I/O operations are encrypted so drives must be partitioned and formatted as if  
they were blank once installed in the Raid Rack. Should a drive with encrypted  
data be removed from the Raid Rack and installed elsewhere, it will appear to  
be completely blank with no partition table or file system.  
Port Multiplier Compatibility  
The R14HPCCES unit only supports configuring the drives in RAID configura-  
tion. For JBOD installations, the R14CCES unit is recommended instead.  
When configured as RAID, the controller is not required to support port  
multipliers.  
Using identical drives for all settings other than JBOD or LARGE is strongly  
recommended. Creating a LARGE array using drives that have different  
properties will use all space on all members, and performance will match that  
of the member in use during any particular I/O operation. Creating a RAID  
using drives that are not all the same size will result in all members using only  
as much space as the smallest member. Creating a RAID using drives that  
have different performance will degrade the overall performance of the array.  
Hot Swapping drives  
The R14HPCCES unit supports hot swapping (inserting or removing drives  
while the drives are running and connected to a computer). The eSATA  
controller on the computer must also support hot swapping - be sure to  
confirm this before attempting to insert or remove drives while the system is  
running. Also be sure to practice the appropriate safe removal procedure  
before proceeding. Failure to practice safe removal procedures will result in  
loss or corruption of data.  
Technical Support (M-F 8:30am - 6:00pm PST)  
Phone: 408-453-6212  
Installation (RAID)  
The Cipher hardware prevents the use of software to configure or manage the  
Port Multiplier. Configuring a RAID mode must be done using the dipswitches  
and SET button on the port multiplier itself, located inside the unit at the rear of  
the chassis.  
Dipswitch  
SET Button  
Installation  
1. Use the provided key to unlock the front door if needed and open it.  
2. Insert a drive into each bay as desired, SATA connectors first, label side up  
as shown, then press the drive firmly into place.  
3. Connect the Host eSATA cable to a computer. If desired, connect an exter-  
nal eSATA drive to the Drive eSATA connector.  
4. Make sure the AC input switch is set correctly, then connect the power cord  
to an AC outlet.  
5. Insert the Cipher Key into the Cipher  
Keyhole.  
6. Set the AC power switch on the rear to  
ON, then press the power button  
behind the front door to turn on the unit.  
7. After the unit has been powered up, the  
Cipher Key may be removed.  
To remove a drive, pull the Eject Lever until  
the drive disengages from the internal  
connector then pull the drive out.  
Port Multiplier Modes  
The Port Multiplier supports several types of RAID and some non-RAID drive  
sets. Each configuration has different properties and requirements, as follows:  
Technical Support (M-F 8:30am - 6:00pm PST)  
Phone: 408-453-6212  
JBOD Mode (Individual Drives)  
Number of drives: at least 1  
Unit capacity: N/A (100% of each individual drive)  
Spares: no  
Fault tolerance: none  
JBOD mode offers all connected units to the host adapter, no RAID is defined at  
all.  
NOTE: JBOD mode is not supported on the R14HPCCES.  
RAID 0 (Stripe set)  
Number of drives: at least 2  
Unit capacity: size of each member times number of members.  
Spares: no  
Fault tolerance: none - if any member is lost all data is lost.  
RAID 0 “stripes” the file system across the array by placing “chunks” of data  
sequentially between drives in a specific order.  
RAID 1 or 10 (Mirror set, Stripe of mirror sets)  
Number of drives: 2 (RAID 1) or 4 (RAID 10).  
Unit capacity: size of one member (RAID 1) or size of two members (RAID 10).  
Spares: yes – if EZ mode is not disabled and 3 (RAID 1) or 5 (RAID 10) drives  
are present, the array will be initialized with a spare.  
Fault tolerance: RAID 1 can withstand the loss of one drive without losing data.  
RAID 10 can withstand the loss of one drive from each mirror set without losing  
data.  
RAID 1 works by duplicating the exact same data on two drives.  
RAID 10 works by using two RAID 1 sets configured as members of a RAID 0.  
Disks 1 and 2 are mirrored, disks 3 and 4 are mirrored, and the two mirror sets  
are striped together.  
RAID 3 (Stripe set with dedicated parity)  
Number of drives: at least 3  
Unit capacity: size of one member times number of members minus one.  
Spares: yes  
Fault tolerance: can withstand the loss of one drive without losing data.  
RAID 3 works by striping data for individual I/O blocks across all members  
except one, which contains parity data for the stripe set computed internally by  
the Port Multiplier. In the event of failure, the missing information can be calcu-  
lated using the parity information.  
Technical Support (M-F 8:30am - 6:00pm PST)  
Phone: 408-453-6212  
RAID 5 (Stripe set with striped parity)  
Number of drives: at least 3  
Unit capacity: size of one member times number of members minus one.  
Spares: yes  
Fault tolerance: can withstand the loss of one drive without losing data.  
RAID 5 works by striping entire I/O blocks across all members of the set, with  
each member taking turns carrying parity data computed by the Port Multi-  
plier. In the event of failure, the missing information can be calculated using  
the parity information.  
CLONE (Mirror set)  
Number of drives: at least 2  
Unit capacity: size of one member.  
Spares: yes  
Fault tolerance: can withstand the loss of any number of drives without losing  
data as long as at least one complete member remains online. CLONE mode  
works the same way as RAID 1, by maintaining a complete copy of the entire  
set of data on each drive.  
LARGE (Spanned set)  
Number of drives: at least 2  
Unit capacity: 100% of all drives together regardless of differences in size  
Spares: no  
Fault tolerance: cannot withstand the loss of any drives without losing data.  
However, some data may be recovered as long as the drive(s) carrying the  
file system data (boot record, directory, etc.) remain online. LARGE mode is  
neither a RAID nor is it a JBOD. It works by declaring the sum of all available  
space of the member drives as a single unit, without striping the data. As  
each member is filled, new data is stored on the next.  
Notes about Spare Drives  
If EZ mode is disabled (SW1:2 ON), all individual drives not configured as  
array members will be offered to the host adapter as separate units.  
To create an array with one or more spares, set or modify the RAID mode  
while the spares are disconnected from the Port Multiplier. When EZ mode is  
enabled (SW1:2 OFF), individual drives connected when an array is present  
are considered spare. Spare drives must be equal to or larger in size than the  
smallest member. When any type of array is defined, individual units will be  
considered spare.  
RAID 0 and LARGE arrays are not fault-tolerant and spare drives will not be  
useful; therefore, disabling EZ for these arrays is recommended. When a  
spare drive is present and a fault-tolerant RAID (1, 10, 3, or 5) is defined, EZ  
mode will automatically rebuild any available spares into the array to replace  
a failed member.  
Technical Support (M-F 8:30am - 6:00pm PST)  
Phone: 408-453-6212  
Configuring the Port Multiplier Using Dipswitches  
Resetting the RAID  
NOTE: This procedure destroys all RAID data. It should not harm individual  
drives or their contents; however, creating backups of all data is strongly recom-  
mended before proceeding.  
Be sure the port multiplier is connected to an active host before proceeding. The  
port multiplier will not complete the process if it has no host connection.  
1. Power down the unit using the AC power switch on the rear, then set the dip  
switch to the desired RAID Mode.  
2. While holding the SET button, turn the unit on. A long beep will sound from the  
Port Multiplier. The SET button may be released once the long beep starts.  
After releasing the SET button, turn on the drives by pressing the power button on  
the front of the unit. Once the drives are ready, the port multiplier should “chirp” to  
indicate the process is complete. If instead of a chirp the Port Multiplier sounds a  
series of short beeps, an error has occurred during the process.  
Setting or Modifying the RAID Mode  
NOTE: Setting or modifying the RAID mode destroys all data.  
Be sure the port multiplier is connected to an active host before proceeding. The  
port multiplier will not complete the process if it has no host connection.  
1. Follow the procedure for resetting the RAID Mode.  
2. Power down the unit using the AC power switch on the rear, then set the dip  
switch to the desired RAID Mode.  
3. While holding the SET button, turn the unit on. A long beep will sound from the  
Port Multiplier. The SET button may be released once the long beep starts.  
After releasing the SET button, turn on the drives by pressing the power button on  
the front of the unit. Once the drives are ready,, the port multiplier should “chirp”  
to indicate the process is complete. If instead of a chirp the Port Multiplier sounds  
a series of short beeps, an error has occurred during configuration of the array.  
BZS Switch (SW1:1):  
The BZS switch is used to silence the audible alarm buzzer. The OFF position  
permits the audible alarm, and the ON position silences the audible alarm. The  
BZS switch has immediate effect.  
EZ Switch (SW1:2):  
The EZ (spare) switch inhibits spares when ON. When in the OFF position, all  
individual drives (not defined as members of an array) are considered spare and  
are not offered to the operating system. Should a RAID become degraded, when  
the EZ switch is in the OFF position a spare drive will be used automatically to  
rebuild the RAID, if present. EZ mode is determined when the unit is powered up.  
Changing the switch will have no effect until the unit has been re-powered.  
Warning: turning off the EZ switch to rebuild an array will consider any drives not  
declared array members to be eligible for rebuild as a spare. Rebuilding will  
destroy all existing data on that drive and the drive chosen is not predictable.  
Disconnect any individual drives with valuable data on them before enabling EZ  
Mode.  
Technical Support (M-F 8:30am - 6:00pm PST)  
Phone: 408-453-6212  
RAID Mode Switches M2, M1, M0 (SW1:3 – SW1-5)  
The RAID Mode switches define what type of RAID will be initialized when the  
unit is powered up while the RAID Mode button is held down, as follows:  
Dipswitch Position  
JBOD (Individual  
Drives)  
1 (BZS)1  
2 (EZ)  
3 (M2)  
OFF  
4 (M1)  
OFF  
5 (M0)  
OFF  
OFF  
OFF2  
* FACTORY  
DEFAULT SETTING  
RAID 0  
RAID 1 OR 10  
RAID 3  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON3  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
ON  
RAID 5  
OFF  
OFF  
ON  
CLONE  
ON  
LARGE  
OFF  
ON  
NOTES:  
1. Audible Alarm is recommended at all times.  
2. EZ mode has no effect when no array is defined.  
3. Disabling EZ for RAID 0 and LARGE is strongly recommended.  
CONTACT US  
Phone:  
Fax:  
408-573-8580  
408-573-8588  
Email:  

Nikon MOTO VE240 User Manual
Kenwood KDC X7006 User Manual
Juniper Networks T1600 User Manual
Jabra DIAL 520 OC User Manual
HP Hewlett Packard HP Drive Enclosure AP844B User Manual
Grindmaster SHUTTLE BREWER APBVSA 330V2E230 User Manual
Emerson Computer Accessories PMPPC7448 User Manual
Continental Electric CM43655 User Manual
Bloomfield 9220 9221 User Manual
Addonics Technologies AE25SN35SA User Manual