ABB JPC 01 User Manual

Options for ABB drives, converters and inverters  
User’s manual  
JPC-01 network communication adapter  
English . . . . . . . . . . . . . . . . . . . . 3  
3AUA0000072233 Rev A  
Effective: 2012-06-26  
2012 ABB Oy. All rights reserved.  
JPC-01 User’s manual 3  
JPC-01 User’s manual  
About this manual  
This manual introduces the installation and start-up of the JPC-01  
network communication adapter module. This manual is intended  
for the people who are responsible for installing, commissioning  
and using a JPC-01 module with an ABB drive. The reader is  
expected to have a basic knowledge of electrical fundamentals,  
electrical wiring practices, the drive, and the use of the drive  
control panel.  
Safety instructions  
WARNING! All electrical installation and maintenance  
work on the drive should be carried out by qualified  
electricians only.  
The drive and adjoining equipment must be properly earthed.  
Do not attempt any work on a powered drive. After switching off the  
supply voltage, always allow the intermediate circuit capacitors to  
discharge for 5 minutes before working on the drive, the motor or  
the motor cable. It is good practice to check (with a voltage  
indicating instrument) that the drive is in fact discharged before  
beginning work.  
These warnings are intended for all who work on the drive.  
Ignoring the instructions can cause physical injury or death, or  
damage the equipment.  
For complete safety instructions see the drive manuals.  
 
4 JPC-01 User’s manual  
Overview  
The JPC-01 module is an RS232-to-RS485 converter with galvanic  
isolation. It enables the use of a PC in a network configuration  
(RS485) to communicate with ACSM1 drives.  
The RS-232 side of the JPC-01 module acts as an interface  
towards the JCU control unit via the RJ45 panel connector. The  
RS-232 side also supplies power to the JPC-01 module.  
The RS-485 side of the JPC-01 module acts as an interface  
towards the PC tool network. It consists of a 4-pin removable  
screw type connector and a termination switch for active  
termination of the RS485 bus. Termination is required only at bus  
ends.  
The JPC-01 supports:  
daisy chained connection of the network cable,  
transmission speeds from 9.6 kbit/s in multiples up to  
57.6 kbit/s,  
a maximum network length of 100 m, and maximum node-to-  
node length of 30 m,  
a maximum of 31 drives in one network.  
The recommended PC adapter is MOXA UPort 1150i USB to 1 port  
RS-232/422/485 adapter with isolation.  
JPC-01 User’s manual 5  
Layout  
Drive status indication LEDs (see section  
LED indications on page 11).  
RS-485 network status indication LEDs  
(see section LED indications on page 11).  
Bus termination selection switch  
ON – Bus termination on  
OFF – Bus termination off  
6 JPC-01 User’s manual  
Installation  
1. Insert the JPC-01 module to the panel port of the JCU control  
unit.  
2. Fasten the screw.  
1
2
JPC-01 User’s manual 7  
RS-485 cabling is done in the bottom direction (parallel with the I/O  
cabling). For details, see appropriate ACSM1 hardware manual.  
The connection terminals are DATA-, DATA+, BGND, SH.  
PC  
RS-232  
RS-485  
max. 31 nodes  
JPC-01 #1  
1 2 3 4  
JPC-01 #2  
1 2 3 4  
JPC-01 #n  
1 2 3 4  
8 JPC-01 User’s manual  
Quick start-up with DriveStudio v1.6  
In DriveStudio v1.6, parameter group 55 COMMUNICATION TOOL  
is used for configuring the network. DriveStudio can be used for  
setting the parameters of one drive at a time and for monitoring the  
signals of several drives simultaneously.  
With parameter 55.01 MDB STATION ID, the node number is set in  
the range of 1…247. With parameter 55.02 MDB BAUD RATE, the  
communication speed is defined. With the default setting, (0) Auto,  
the initial speed at power-up or after communication loss is  
9600 bit/s. Note: Parameter 55.02 must be set to (0) Auto when  
using a control panel.  
1. Ensure that your PC is connected to one of the drives at a time  
when configuring the RS-485 network. There are three ways to  
do the connection:  
Point-to-point connection from the PC directly to one of the  
JCUs  
Each JPC-01 connected to its JCU but only one JCU  
powered (network connection)  
Only one JPC-01 in the RS-485 chain connected to a JCU  
(remaining JPC-01s detached from the JCU).  
2. Set parameter 55.01 MDB STATION ID to a value between 1  
and 31.  
JPC-01 User’s manual 9  
3. Set parameter 55.02 MDB BAUD RATE to the value of  
57600 bit/s.  
4. Repeat the procedure (steps 1…3) for the remaining drives;  
connect the drives to the PC tool network one by one.  
Note: The new settings for parameters 55.01 and 55.02 become  
valid when the communication is interrupted either by restarting  
DriveStudio, removing the communication cable or restarting the  
JCU.  
5. After having configured group 55 for each drive, select OPC  
Server Settings from the Edit menu.  
6. Launch the ABBCOMSAP server configuration window from  
the taskbar.  
COM Port shows all currently available COM ports.  
Default (247) defines the node number that DriveStudio  
uses when it communicates with the drives. With the box  
ticked, the node number used is 247 which represents a  
broadcast message to each drive (no response). With the  
box unticked, the node number range during the scan  
10 JPC-01 User’s manual  
cycle is defined by the Start node and End node fields. By  
limiting the range the scan takes less time to finish.  
Default Speeds defines the baud rate used during the  
node scan cycle and normal communication. With the box  
ticked, the node scan is performed at 9600 bit/s; the speed  
is then increased to the maximum. With the box unticked,  
the speeds are defined by the Scan Speed and Comm  
Speed fields respectively.  
Leave the Default (247) and Default Speeds boxes ticked  
(default) during the point-to-point connection (steps 1…3).  
7. Check the COM port used from DriveStudio.  
8. Untick the boxes Default (247) and Default Speeds in the  
COM port used.  
9. Change the setting of End node according to the maximum  
number of nodes.  
10. Change the setting of Scan Speed to 57600 bit/s.  
11. Leave the setting of Comm Speed on 57600 bit/s.  
8
9
8
10  
11  
12. Click OK.  
13. Connect all drives to the RS-485 network.  
14. Scan the network by selecting View Refresh or restarting  
DriveStudio.  
15. DriveStudio will show all drives connected to the network.  
JPC-01 User’s manual 11  
Fault tracing  
LED indications  
Indication of drive status  
Name  
POWER  
FAULT  
Color  
Green  
Red  
Meaning  
Drive powered  
Drive faulted  
Indication of network (RS-485) status  
Name  
RXD  
TXD  
Color  
Green  
Green  
Meaning  
Receive data  
Transmit data  
Technical data  
Operating voltage: 24 V DC ± 10% (supplied by the drive)  
Power consumption: max 1.2 W  
Ambient conditions  
Operating temperature: 0…60 °C  
Storage temperature: -40…+70 °C  
Max. relative humidity: 95% (non-condensing)  
Lifetime: 100 000 h  
Standards  
Complies with EMC standard EN 61800-3:2004.  
PCB materials are UL recognized.  
All materials must be RoHS compatible.  
 
12 JPC-01 User’s manual  
Dimensions  
Further information  
Product and service inquiries  
Address any inquiries about the product to your local ABB  
representative, quoting the type designation and serial number of  
the unit in question. A listing of ABB sales, support and service  
contacts can be found by navigating to www.abb.com/drives and  
selecting Sales, Support and Service network.  
Product training  
For information on ABB product training, navigate to  
www.abb.com/drives and select Training courses.  
Providing feedback on ABB Drives manuals  
Your comments on our manuals are welcome. Go to  
www.abb.com/drives and select Document Library Manuals  
feedback form (LV AC drives).  
Document library on the Internet  
You can find manuals and other product documents in PDF format  
on the Internet. Go to www.abb.com/drives and select Document  
Library. You can browse the library or enter selection criteria, for  
example a document code, in the search field.  

MTD 462 thru 465 User Manual
Memorex MPD8507 User Manual
Maxtor DIAMONDMAX 22 STM3320614AS User Manual
LG Electronics 357 User Manual
JVC CA MXKC2 User Manual
Hitachi Travelstar HTS725050A9A364 User Manual
Hitachi Travelstar HTS725025A7E635 User Manual
FieldServer Gamewell FCI E3 Series User Manual
Echo Bear Cat 70554 User Manual
Curtis CD266 User Manual