Vulcan Hart ML 052211 User Manual

SERVICE MANUAL  
HEAVY DUTY GAS BROILER  
MODELS  
GHCB40  
ML-052211  
ML-052213  
ML-052214  
ML-052202  
ML-052208  
ML-052200  
ML-052201  
ML-052210  
GHCB44  
GHMCB44  
HCB1  
HCB2(B)  
IR1  
IR2(B)  
GHIR44  
GHCB40SHOWN  
– NOTICE –  
ThisManualispreparedfortheuseoftrainedVulcanServiceTechniciansandshouldnotbeusedbythosenotproperly  
qualified.IfyouhaveattendedaVulcanServiceSchoolforthisproduct,youmaybequalifiedtoperformalltheprocedures  
described in this manual.  
This manual is not intended to be all encompassing. If you have not attended a Vulcan Service School for this product,  
you should read, in its entirety, the repair procedure you wish to perform to determine if you have the necessary tools,  
instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools,  
instruments and skills should be performed by a trained Vulcan Service Technician.  
Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.  
For additional information on Vulcan-Hart Company or to locate an authorized  
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791  
FORM 35608 (Aug. 2003)  
Gas Valves, Tubing, Thermostats, Regulators and Solenoids.................................................................... 18  
Burner Manifold Assembly (GHCB40) ................................................................................................. 18  
Burner Manifold Assembly (GHIR44) .................................................................................................. 19  
Oven Pilot Valve (GHCB40) .............................................................................................................. 19  
Oven Burner Valve (GHCB40) ............................................................................................................ 19  
Pilot Outage Protection Valve (GHCB40) ........................................................................................... 20  
Thermostat (GHCB40) ....................................................................................................................... 21  
Oven Burner Nozzle (GHCB40).......................................................................................................... 22  
Burner Valve [(IR2(B) and HCB2(B)].................................................................................................... 22  
Burner Valve (GHIR44) ........................................................................................................................ 23  
Regulator (GHIR44)............................................................................................................................. 23  
Regulator [HCB2(B)] ........................................................................................................................... 24  
Solenoid (GHIR44) .............................................................................................................................. 24  
Lever Arm Assembly (All Models) ............................................................................................................. 25  
Upper .................................................................................................................................................. 25  
Lower .................................................................................................................................................. 25  
Blower and Motor ...................................................................................................................................... 26  
GHIR44............................................................................................................................................... 26  
IR1 and IR2(B) .................................................................................................................................... 27  
Blower Switch (GHIR44) ..................................................................................................................... 27  
Light (GHIR44) .................................................................................................................................... 28  
SERVICE PROCEDURES AND ADJUSTMENTS .................................................................................................. 28  
Gas Supply Checks .................................................................................................................................. 28  
Regulator Adjustment (All Models) ............................................................................................................ 28  
Pilot Adjustment (All Models) .................................................................................................................... 29  
Burner Venturi Air Shutter Adjustment [GHCB40 and HCB2(B)] ................................................................. 29  
Burner Service (All Models)....................................................................................................................... 30  
Burner Orifice Service (All Models) ........................................................................................................... 30  
TROUBLESHOOTING............................................................................................................................................ 31  
– 3 –  
GENERAL  
SPECIFICATIONS  
INTRODUCTION  
Gas Data  
This service manual was specially written for the  
Heavy Duty Gas Broilers.  
Dimensions  
No. of  
Total  
Burners BTU  
Model  
per  
/hr  
Width Depth Height  
INSTALLATION AND OPERATION  
Section  
GHCB40  
GHCB44  
34”  
34”  
391/8  
391/8  
391/8  
383/8  
383/8  
383/8  
383/8  
381/4  
79”  
79”  
4
4
4
4
4
4
4
4
100,000  
100,000  
100,000  
50,000  
Detailed installation and operation instructions are  
included in the Installation and Operation Manual  
which is sent with each Broiler.  
GHMCB44 34”  
57”  
CLEANING  
HCB1  
HCB2(B)  
IR1  
36”  
36”  
36”  
36”  
34”  
68”  
801/2  
69”  
100,000  
80,000  
Detailed cleaning instructions are included in the  
Installation and Operation Manual for the appropriate  
model.  
IR2(B)  
GHIR44  
801/2  
82”  
160,000  
80,000  
LIGHTING PILOT  
Detailed lighting pilot instruction are included in the  
Installation and Operation Manual for the appropriate  
model.  
TOOLS  
Standard  
DATA PLATE LOCATION  
GHCB40  
• Hand tools (standard set)  
• Volt-Ohmmeter (VOM) with AC current tester  
(any quality VOM with a sensitivity of at least  
20,000 ohms per volt can be used).  
Behind the oven kick panel riveted to left corner of  
the oven burner box. (Removal of the kick panel is  
necessary to access plate.)  
• Gas test kit  
HCB1/2(B)  
• Temperature tester (thermocouple or digital  
pyrometer)  
Riveted to front right-hand corner of the lower shelf.  
• Temperature tester (thermocouple type).  
• Manometer  
GHIR44  
Riveted to the door liner behind the left hand door  
panel.  
IR1/2(B)  
Riveted to lower cabinet bottom shelf.  
– 4 –  
IMPORTANT  
STOP BOLTS MUST BE IN POSITION FOR SAFE OPERATION OF GRID. IF DAMAGED OR MISSING,  
REPLACE AT ONCE. DO NOT OPERATE GRID WITHOUT BOLTS.  
Two (2) broiler grid 1/4-20 stop bolts and nuts are supplied with each broiler grid to ensure that the grid is not  
accidentally pulled completely from the broil section while hot. One (1) stop bolt and nut are mounted to the grid  
carriage RT. and LT. HD. side member through a 0.281 diameter hole directly in front of the grid stop tab. The  
stop nuts and bolts are screwed tightly against the side members and are properly adjusted extending  
approximately 1/2” below the stop tab as shown in the above photo.  
– 5 –  
REMOVAL AND REPLACEMENT OF PARTS  
5. Lift and remove the burner box cover from the  
broiler.  
COVERS, PANELS AND HANDLES  
6. Reverse the procedure to install.  
Burner Box Cover (GHCB40, GHCB44,  
GHIR44)  
Burner Shield Cover [HCB2(B), IR1,  
IR2(B)]  
WARNING: SHUT OFF THE GAS BEFORE  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
SERVICING.  
NOTE: The models HCB2(B) and IR2(B) have two  
burner shield covers.  
1. Open the augratin oven door.  
2. Remove the oven rack.  
1. Removethetwoscrewsfromtheburnershield  
cover and the broiler.  
2. Lift and remove the burner shield cover from  
the broiler.  
3. Reverse the procedure to install.  
3. Remove the four screws and bushings from  
the oven.  
4. Remove the augratin oven bottom assembly  
asoutlinedinAugratinOvenBottomAssembly.  
– 6 –  
Manifold Cover Assembly  
(GHCB40 & GHIR44)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
1. Remove the grease tray from the broiler  
(GHCB40 only).  
1. Loosen the mounting screw in each burner  
knob.  
NOTE: The GHIR44 manifold cover assembly has  
a chain to protect switch wiring.  
2. Remove the burner knob.  
2. Loosen the mounting screw in each burner  
knob.  
3. Removethetwoburnerknobsfromthebroiler.  
4. Remove the two screws from the manifold  
cover assembly.  
5. Remove the manifold cover assembly from  
the broiler.  
6. Reverse the procedure to install.  
Burner Knob Cover Plate [  
HCB2(B), IR1 and IR2(B)]  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
3. Remove two screws from the burner knob  
cover plate and the broiler.  
4. Slide the burner knob cover plate out and  
remove it from the broiler.  
5. Reverse the procedure to install.  
– 7 –  
4. Remove the bolt and the control panel cover  
from the broiler.  
Control Panel Cover (GHCB40)  
1. Remove the manifold cover assembly as  
outlined in Manifold Cover Assembly.  
5. Reverse the procedure to install.  
Lower Front Panel (GHCB40)  
1. Grasp the bottom of the lower front panel.  
2. Pull the lower front panel out to remove it from  
the broiler.  
2. Loosen the retaining screw and remove the  
burner knob from the broiler.  
3. Reverse the procedure to install.  
3. Pull the thermostat knob to remove it from the  
broiler.  
Oven Burner Cover (GHCB40)  
1. Remove the lower front panel as outlined in  
Covers, Panels and Handles.  
2. Removethescrewfromtheovenburnercover.  
3. Remove the oven burner cover from the  
broiler.  
4. Reverse the procedure to install.  
– 8 –  
Oven Bottom Assembly (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the lower front panel as outlined in  
Covers, Panels and Handles.  
2. Open oven door.  
3. Remove rack if necessary.  
7. Remove the oven bottom baffle from the  
broiler.  
8. Remove the oven insulation sheet.  
4. Remove the two screws and brass bushings  
from the broiler.  
5. Loosen the two bolts on the retainer brackets.  
6. Remove the oven bottom assembly from the  
broiler.  
9. Remove the oven bottom tray.  
10. Reverse the procedure to install.  
– 9 –  
Augratin Oven Bottom Assembly  
(GHCB40)  
WARNING: ALL GAS JOINTS DISTURED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
3. Remove the augratin oven bottom baffle from  
the broiler.  
4. Reverse the procedure to install.  
NOTE: When installing bottom assembly, angle  
metal should be at the rear of the oven.  
Oven Door Handle (GHCB40)  
1. Remove the four screws and brass bushings  
from the broiler.  
1. Remove the caps from the oven door.  
2. Slide the augratin oven bottom assembly from  
the broiler.  
– 10 –  
GRID CARRIAGE ASSEMBLY  
(ALL MODELS)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
WARNING: SPRING AND HOOK BOLT ARE  
UNDER TENSION.  
1. Remove the broiler grid tray as outlined in  
Broiler Grid Tray.  
2. Remove two screws and the oven door handle  
from the oven door.  
2. Remove cover manifold cover assembly as  
outlined in Covers, Panels and Handles.  
3. Reverse the procedure to install.  
BROILER GRID TRAY (ALL MODELS)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
1. Allow the broiler grids to cool.  
3. Carefully remove the two springs from the  
threaded hook bolts and the lower lever arm  
assembly.  
2. Remove the two broiler grids from the broiler  
grid tray.  
3. Remove two stop bolts and nuts from the  
broiler.  
4. Carefullypulloutthebroilergridtraytoremove  
it from the grid carriage.  
5. Reverse the procedure to install.  
– 11 –  
BURNER CERAMICS (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
NOTE: Lower broiler pan for easier access.  
1. Allow the burner ceramics to cool.  
4. Remove the grid handle from the grid arm  
lifting assembly.  
5. Remove two bolts, six washers and two nuts  
from the grid arm lifting assembly and the grid  
carriage assembly.  
6. Remove the grid arm lifting assembly from  
the grid carriage assembly and the broiler.  
2. Carefully push up on the side and center  
ceramics to remove from the broiler.  
3. Reverse the procedure to install.  
7. Remove the four cotter pins and bolts (two  
each side) from the lever arm bracket and  
upper and lower lever arm assemblies.  
NOTE: When installing grid arm lifting assembly,  
install washers between grid arm lifting assembly  
and grid carriage assembly.  
8. Reverse the procedure to install.  
– 12 –  
GHIR44  
BURNER ASSEMBLY  
WARNING: SHUT OFF THE GAS BEFORE  
GHCB40 & HCB2(B)  
SERVICING.  
1. Allow the burner assembly to cool.  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
1. Removetheburnerceramicsasoutlinedunder  
Burner Ceramics.  
2. Remove burner box cover as outlined in  
Controls, Panels and Handles.  
2. Lift the rear of the burner assembly off the  
alignment pins.  
3. Carefully move the burner assembly to the  
rear of the broiler and then remove burner  
from the broiler.  
3. Allow the burner assembly to cool.  
4. Lifttherearoftheburnerassemblyandremove  
it from the broiler.  
CAUTION: Makesurethatyoudonotdamagethe  
pilot burner nozzle when you remove the burner  
assembly.  
CAUTION: Makesurethatyoudonotdamagethe  
pilot nozzle when you remove the burner  
assembly.  
4. Reverse the procedure to install.  
5. Reverse the procedure to install.  
– 13 –  
HEAT SHIELD (GHIR44)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
1. Remove burner assemblies as outlined in  
Burner Assembly.  
4. Remove the pilot elbow nozzle from sub-  
manifold assembly.  
5. Reverse the procedure to install.  
SUB-MANIFOLD ASSEMBLY  
GHCB40  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
2. Remove the cotter pin from the shaft of the  
heat shield.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
3. Remove the heat shield from the broiler.  
4. Reverse the procedure to install.  
PILOT ELBOW NOZZLE  
1. Remove the burner box cover as outlined in  
Covers, Panels and Handles.  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
2. Remove the burner assemblies as outlined in  
Burner Assemblies.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
3. Remove the pilot elbow nozzles as outlined in  
Pilot Elbow Nozzle.  
1. Remove the burner box cover as outlined in  
Covers, Panels and Handles.  
2. Remove the burner assemblies as outlined in  
Burner Assemblies.  
3. Allow the pilot elbow nozzles to cool.  
– 14 –  
3. Remove the two nuts and washers from the  
sub-manifold and the bracket.  
4. Disconnect the sub-manifold from the elbow.  
5. Remove the sub-manifold from the broiler.  
6. Reverse the procedures to install.  
BURNER SUB-MANIFOLD (GHIR44)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
NOTE: These procedures apply to the left and right  
side burner subassemblies.  
4. Disconnect the burner tubing fitting from the  
sub-manifold assembly.  
1. Remove the burner box cover as outlined in  
Covers, Panels and Handles.  
5. Loosen the two nuts on the sub-manifold  
assembly and the brackets.  
2. Remove the burner assemblies as outlined in  
Burner Assemblies.  
6. Remove the sub-manifold assembly from the  
broiler.  
3. Remove the elbow pilot nozzles as outlined in  
Pilot & Elbow Nozzle.  
7. Reverse the procedure to install.  
GHIR44  
1. Remove the manifold cover assembly as  
outlined in Covers, Panels and Handles.  
2. Disconnect the burner valves from the sub-  
manifold as outlined in Burner Valves  
(GHIR44).  
4. Disconnect the burner tubing fitting from the  
burner sub-manifold.  
– 15 –  
5. Loosen the two nuts on the burner sub-  
manifold.  
6. Remove the burner sub-manifold from the  
broiler.  
3. Disconnect the four pilot burner nozzles from  
the pilot manifold.  
7. Reverse the procedure to install.  
PILOT MANIFOLD (GHIR44)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the burner box cover as outlined in  
Covers, Panels and Handles.  
4. Remove the two washers and nuts from the  
pilot manifold.  
5. Remove the pilot manifold from the broiler.  
6. Reverse the procedure to install.  
2. Disconnect the pilot tube from the pilot  
manifold.  
– 16 –  
OVEN BURNER ASSEMBLY (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Removetheovenbottomassemblyasoutlined  
in Covers, Panels and Handles.  
3. Remove the two screws and plate from the  
broiler.  
2. Lift and remove the oven burner assembly  
from the broiler.  
3. Reverse the procedure to install.  
4. Remove the two screws and the pilot burner  
nozzle from the pilot support housing.  
PILOT BURNER NOZZLES (GHIR44)  
5. Remove the pilot burner nozzle from the  
broiler.  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
6. Reverse the procedure to install.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the burner box cover as outlined in  
Covers, Panels and Handles.  
2. Remove the pilot manifold as outlined in Pilot  
Manifold.  
– 17 –  
GAS VALVES, TUBING,  
THERMOSTATS, REGULATORS  
AND SOLENOIDS  
Burner Manifold Assembly (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the manifold cover assembly as  
outlined in Covers, Panels and Handles.  
6. Disconnect the oven gas supply tube from the  
burner manifold assembly.  
NOTE: For proper alignment of the gas tubing,  
make sure you do not change the position of the stop  
nuts.  
2. Disconnect the burner tubing from the burner  
valves.  
3. Disconnect the pilot supply tubing from the  
pilot valve.  
4. Removethetwoburnervalvesfromtheburner  
manifold assembly.  
7. Remove the two nuts and two washers from  
the threaded rod.  
5. Remove the pilot valve from the burner  
manifold assembly.  
8. Hold the burner manifold assembly and  
removethetwobolts, manifoldholdingbracket  
and two washers from the broiler.  
9. Reverse the procedure to install.  
– 18 –  
Burner Manifold Assembly (GHIR44)  
Oven Pilot Valve (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the manifold cover assembly as  
outlined in Covers, Panels and Handles.  
1. Remove the control panel cover as outlined in  
Covers, Panels and Handles.  
2. Disconnect the drop pipe from the burner  
manifold assembly  
NOTE: For proper alignment of the gas tubing,  
make sure you do not change the position of the stop  
nuts.  
2. Disconnect the pilot tubing from the oven pilot  
valve.  
3. Remove the oven pilot valve from the gas  
supply tube.  
4. Reverse the procedure to install.  
Oven Burner Valve (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
3. Remove the two nuts and two washers from  
the threaded rod.  
1. Remove the control panel cover as outlined in  
Covers, Panels and Handles.  
4. Hold the burner manifold assembly and  
removethetwobolts, manifoldholdingbracket  
and two washers from the broiler.  
5. Reverse the procedure to install.  
– 19 –  
2. Disconnect the oven burner valve from the  
oven gas supply tube and the union.  
3. Disconnect the pilot valve tubing from the pilot  
outage protection valve.  
3. Reverse the procedure to install.  
4. Removetheovenbottomassemblyasoutlined  
in Covers, Panels and Handles.  
Pilot Outage Protection Valve (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the control panel cover as outlined in  
Covers, Panels and Handles.  
2. Remove the lower front panel as outlined in  
Covers, Panels and Handles.  
5. Loosen the b-nut and remove the ignitor wire  
from the bracket.  
– 20 –  
6. Remove the two bolts from the pilot outage  
protection valve and the bracket.  
3. Disconnect the thermostat from the pilot  
outage protection valve and from the oven  
burner tubing.  
7. Disconnect the pilot outage protection valve  
from the union and the thermostat.  
8. Remove the pilot outage protection valve and  
the ignitor wire from the broiler.  
9. Reverse the procedure to install.  
Thermostat (GHCB40)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
4. Removethetemperatureprobefromtheoven.  
1. Remove the control panel cover as outlined in  
Covers, Panels and Handles.  
5. Remove the thermostat with the temperature  
probe from the broiler.  
2. Note the location and position of the  
temperature probe in the oven.  
6. Reverse the procedure to install.  
– 21 –  
Oven Burner Nozzle (GHCB40)  
Burner Valve [(IR2(B) and HCB2(B)]  
WARNING: SHUT OFF THE GAS BEFORE  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the oven burner cover as outlined in  
Covers, Panels and Handles.  
1. Remove the burner knob cover plate as  
outlined in Covers, Panels and Handles.  
2. Disconnect the oven burner tubing from the  
oven burner nozzle.  
3. Remove the oven burner nozzle from the  
bracket.  
2. Disconnect the burner valve from the elbow  
and the burner tubing.  
4. Remove the oven burner nozzle from the  
broiler.  
3. Reverse the procedure to install.  
5. Reverse procedure to install.  
– 22 –  
Burner Valve (GHIR44)  
Regulator (GHIR44)  
WARNING: DISCONNECT THE ELECTRICAL  
POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
WARNING: DISCONNECT THE ELECTRICAL  
POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
WARNING: SHUT OFF THE GAS BEFORE  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the manifold cover assembly as  
outlined in Covers, Panels and Handles.  
1. Open the lower doors to gain access to the  
regulator.  
2. Disconnect the regulator from the pipe elbow  
and the solenoid.  
2. Disconnect the burner tubing from the burner  
valve.  
3. Remove the regulator from the broiler.  
4. Reverse the procedure to install.  
3. Disconnect the burner valve from the sub-  
manifold.  
4. Remove the burner valve from the broiler.  
5. Reverse the procedure to install.  
– 23 –  
Regulator [HCB2(B)]  
Solenoid (GHIR44)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: DISCONNECT THE ELECTRICAL  
POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Open the lower doors to get access to the  
solenoid.  
1. Disconnectthegassupplytubeandtheburner  
tube.  
2. Remove the regulator from the broiler.  
3. Reverse the procedure to install.  
2. Note the location and connection of the  
electrical wires.  
3. Disconnect the electrical wires.  
4. Disconnect the solenoid from the burner pipe  
and the regulator.  
5. Remove the solenoid from the broiler.  
6. Reverse the procedure to install.  
– 24 –  
Lower  
LEVER ARM ASSEMBLY  
(ALL MODELS)  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
Upper  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: ALL GAS JOINTS DISTURBED  
DURING SERVICING MUST BE CHECKED FOR  
LEAKS. CHECK WITH SOAP AND WATER  
SOLUTION (BUBBLES). DO NOT USE AN OPEN  
FLAME.  
1. Remove the grid carriage assembly as  
outlined in Grid Carriage Assembly.  
1. Remove the grid carriage assembly as  
outlined in Grid Carriage Assembly.  
2. Remove two screws and the lower lever cover  
from the broiler.  
2. Remove the two cotter pins and washers from  
the upper lever arm assembly.  
3. Remove the upper lever arm assembly from  
the two brackets.  
4. Reverse the procedure to install.  
– 25 –  
2. Remove the four screws from the bracket and  
blower and motor.  
3. Move the bracket away from the blower and  
motor.  
3. Remove the two cotter pins and washers from  
the lower lever arm assembly.  
4. Remove the lower lever arm assembly from  
the two brackets.  
5. Reverse the procedure to install.  
BLOWER AND MOTOR  
GHIR44  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
WARNING: DISCONNECT THE ELECTRICAL  
POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
4. Remove the four screws and nuts from the air  
duct and the blower and motor.  
1. Open the lower doors to get access to the  
blower and motor.  
5. Carefully remove the six screws from the  
blower and motor and the brackets.  
6. Remove the air duct from the broiler.  
7. Note the location and connection of the  
electrical wires.  
– 26 –  
Blower Switch (GHIR44)  
WARNING: DISCONNECT THE ELECTRICAL  
POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
1. Remove the manifold cover assembly as  
outlined in Covers, Panels and Handles.  
8. Disconnect the electrical wires.  
9. Removetheblowerandmotorfromthebroiler.  
10. Reverse the procedure to install.  
IR1 and IR2(B)  
WARNING: DISCONNECT THE ELECTRICAL  
POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
2. Remove the nut from the manifold cover  
assembly and the switch.  
WARNING: SHUT OFF THE GAS BEFORE  
3. Note the location and connection of the  
electrical wires.  
SERVICING.  
1. Remove the screws and the bracket and the  
blower and motor.  
2. Remove the screws and nuts from the air duct  
and the blower and motor.  
3. Carefully remove the screws from the blower  
and motor and the brackets.  
4. Carefully remove the air duct from the blower  
and motor.  
5. Note the location and connection of the  
electrical wires.  
6. Disconnecttheelectricalwiresfromtheblower  
and motor.  
4. Disconnect the electrical wires.  
5. Reverse the procedures to install.  
7. Removetheblowerandmotorfromthebroiler.  
8. Reverse the procedure to install.  
– 27 –  
Light (GHIR44)  
WARNING: DISCONNECT THE ELECTRICAL  
POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
WARNING: SHUT OFF THE GAS BEFORE  
SERVICING.  
1. Remove the manifold cover assembly as  
outlined in Covers, Panels and Handles.  
2. Note the location and connection of the  
electrical wires.  
3. Disconnect the electrical wires from the light.  
4. Reverse the procedure to install.  
SERVICE PROCEDURES AND ADJUSTMENTS  
GAS SUPPLY CHECKS  
If the gas supply piping is to be tested at a test pressure in excess of 1/2 psi (3.45 kPa), the appliance and its  
individual shutoff valve must be disconnected from the supply line. If the gas supply piping is to be tested at a  
pressure equal to or less than 1/2 psi (3.45 kPa), the individual shutoff valve must be closed during testing.  
3. Light all burners and take a reading.  
REGULATOR ADJUSTMENT  
(ALL MODELS)  
4. Light all the gas appliances on the same  
supply line and take a reading.  
WARNING: SHUT OFF THE GAS BEFORE  
A. At no time should the pressure drop more  
than 1/2” W.C. A large pressure drop  
could be an indication that the gas supply  
line is too small or a blockage. Check  
supply line pressure to ensure that it is at  
least 1.0” greater than the specified  
operating pressure of the broiler. Check  
with the gas provider for the proper size  
gas line.  
SERVICING.  
Accurate gas pressure adjustment can only be made  
with the gas on and the burner lit. In addition the  
supply line pressure to the broiler must be at least  
1.0” W.C. greater than what is stated on the broiler  
unit rating plate.  
Regulatorsarepreadjustedfornaturalorpropanegas  
as specified on the broiler rating plate.  
1. Connect the manometer to the main gas  
manifold pipe of the broiler. Turn on gas.  
2. Light one burner and take a reading.  
– 28 –  
PILOT ADJUSTMENT  
(ALL MODELS)  
1. Light the pilot as outlined under Lighting Pilot  
in the Installation and Operation manual for  
the appropriate model.  
2. Locate the pilot adjustment screw on the  
supply end of pilot manifold pipe.  
3. With a flat blade screwdriver, turn the pilot  
adjustment screw counterclockwise to  
increase or clockwise to decrease gas flow.  
The flame should only be high enough to  
ignite the burner in less than 4 seconds.  
4. Turn the burner on . If the flame is soft, lazy or  
yellow, there is not enough primary air and  
the air shutter needs to be opened up. If the  
flame is lifting off the burner, there is too  
much primary air and the air shutter needs to  
be closed down.  
BURNER VENTURI AIR SHUTTER  
ADJUSTMENT  
[GHCB40 AND HCB2(B)]  
The gas burners have a disk type air shutter. The disk  
type is used on cast iron burners. All burners are  
tested and the air shutters are set at the factory prior  
to shipment. However, fine tuning adjustments may  
be necessary.  
5. Rotate the air shutter so that a blue flame  
without any yellow tipping is seen across the  
burner.  
6. Oncetheproper adjustment is made, carefully  
tighten the adjustment screw without moving  
the air adjuster.  
When using natural gas, the air shutter will be  
approximately 50% open. On propane (LP), the air  
shutter will be approximately 90% open.  
7. Install front covers when complete.  
1. For GHCB40 remove the burner box cover as  
outlined under Covers, Panels and Handles  
in Removal and Replacement of Parts Section  
of this manual.  
2. For HCB2(B) remove the burner box cover as  
outlined under Covers, Panels and Handles in  
RemovalandReplacementofPartsSectionof  
this manual.  
3. Loosen the air shutter adjustment screw.  
– 29 –  
BURNER SERVICE (ALL MODELS)  
WARNING: SHUT OFF THE GAS BEFORE SERVICING THE OVEN.  
If the burner ports become obstructed or the burner cracks, the burner will not operate properly.  
1. Remove burner(s) as outlined under Burner Assemblies Section of this manual.  
2. Check burner(s) for:  
A. Obstruction in port holes.  
1) Soak the burner(s) in warm, soapy water. If this does not solve the problem, the obstruction may  
be removed by carefully inserting, by hand, the proper size drill bit. If severe clogging or damage  
is evident, replace the burner(s).  
B. Cracks in burner body.  
1) Burner must be replaced.  
BURNER ORIFICE SERVICE (ALL MODELS)  
WARNING: SHUT OFF THE GAS BEFORE SERVICING.  
1. Remove the burner associated with the orifice to be serviced as outlined under Burner Assemblies.  
2. Remove the orifice tip and check for obstructions or damage.  
3. Soak the orifice(s) in warm, soapy water. If this does not solve the problem, the obstructions may be  
removed by carefully inserting, by hand, the proper size drill bit. If severe clogging or damage is evident,  
replace the orifice(s).  
4. Reverse the procedure to install.  
– 30 –  
TROUBLESHOOTING  
SYMPTOMS  
POSSIBLE CAUSES  
Uneven heating, sides burning.  
A) Temperature too low.  
B) Improper operation of broiler.  
C) Fluctuating gas pressure.  
Too much top heat.  
A) Temperature too high.  
B) Faulty ventilation.  
C) Excessive heat input.  
D) Gas pressure too high or orifice too large.  
Uneven heat front to back.  
Dried out products.  
A) Appliance not level front to back.  
A) Broiling time too long or product too close to the burner.  
B) Gas pressure too high or orifice too large.  
Pilot outage.  
A) Pilot flame too low.  
B) Restriction in pilot orifice.  
Pilot will not light.  
A) Insufficient gas input.  
B) Poor air to gas adjustment.  
C) Restriction in pilot orifice.  
D) Restriction in main burner port.  
E) Pilot adjustment incorrect.  
– 31 –  
FORM 35608 (Aug. 2003)  
PRINTED IN U.S.A.  
– 32 –  

Yorkville Sound Car Amplifier AP4020 User Manual
Viking TMC 148 User Manual
Universal Electronics UNV 35809 User Manual
Sony Handycam DCRDVD308 User Manual
Sony DCR HC33E User Manual
Sony CX700E User Manual
Sirius Satellite Radio 051707a User Manual
Sharp SCL901 User Manual
Sanyo Xacti VPC GH2 User Manual
Samsung SCD87 User Manual