Siemens Spectrodensitometer FD 5 User Manual

Spectrodensitometer  
Main specifications  
Model  
FD-7  
  
FD-5  
45°a: 0°(annular illumination)  
Illumination/viewing system  
Spectral separation device  
Wavelength range  
Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for reflectance measurements.  
Concave grating  
- -  
FD 7/FD 5  
Spectral reflectance: 380 to 730 nm; Spectral irradiance: 360 to 730  
nm  
Spectral reflectance: 380 to 730 nm  
Wavelength pitch  
Half bandwidth  
10 nm  
Approx. 10 nm  
Measurement area  
Light source  
Ø3.5mm  
LED  
Measurement range  
Density: 0.0D to 2.5D; Reflectance: 0 to 150%  
Density: σ0.01D  
Short-term repeatability  
Colorimetric: Within σΔE00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)  
Within ΔE00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard  
conditions)  
Inter-instrument agreement  
Measurement time  
3-in-1 next-generation measurement tool  
Approx. 1.4 s (single-point reflectance measurement)  
Colorimetric values, color-difference values, density values, density-  
difference values, dot area ratio, dot gain, PASS/FAIL judgment  
Colorimetric values, color-difference values, density values,  
density-difference values, dot area ratio, dot gain, PASS/FAIL  
judgment, illuminance, correlated color temperature  
Displayed values  
Color  
Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut  
filter); User-defined illuminant  
Measurement conditions  
Illuminants  
A, C, D50, D65, ID50, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defined illuminant  
2° Standard Observer, 10° Standard Observer  
Observers  
    
Density  
Illumination  
Color spaces  
Color-difference equations  
Indexes  
L a b , L C h, Hunter Lab, Yxy, XYZ and color-difference in these color spaces  
ΔE ab (CIE 1976), ΔE 94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l:c)  
WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index  
ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536  
Density  
Storable data  
Display language  
Colorimetric target data: 30 data; Density target data: 30 data  
English, French, German, Spanish, Japanese, Chinese (Simplified)  
  
Scanning measurements  
Interface  
Scanning measurement of a color chart can be performed.  
USB 2.0  
N/A  
Displayed values; Spectral reflectance data; Spectral irradiance  
data  
  
Output data  
Displayed values  
Power  
Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power  
70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached)  
Dimensions (W × D × H)  
Weight  
Approx. 350g (Body only); Approx. 430g (With target mask attached)  
Operating temperature/  
humidity range  
10 to 35°C, 30 to 85% relative humidity with no condensation  
0 to 45°C, 0 to 85% relative humidity with no condensation  
Storage temperature/humidity  
range  
1 Illumination for wavelengths under 400nm is unidirectional. 2 Available when using PC software.  
• Displays shown are for illustration purpose only.  
(Units: mm)  
• The specifications and drawings given here are subject to change without prior notice.  
• KONICA MINOLTA and the Konica Minolta logo and the symbol mark, and "Giving Shape to  
Ideas" are registered trademarks or trademarks of KONICA MINOLTA HOLDINGS, INC.  
• The basICColor logo is a registered trademark of basICColor GmbH.  
• Other company names and product names used herein are trademarks or registered trademarks  
of their respective companies.  
DIMENSIONS  
With removable target mask attached  
90  
70  
171.5  
165  
SAFETY PRECAUTIONS  
For correct use and for your safety, be sure to read the instruction  
manual before using the instrument.  
Always connect the instrument to the specified power supply  
s
voltage. Improper connection may cause a fire or electric shock.  
25  
φ6.2  
Certificate No : LRQ 0960094/A  
Registration Date : March 3, 1995  
Certificate No : JQA-E-80027  
Registration Date : March 12, 1997  
Streamlines color adjustment  
in printing, even on substrates  
with fluorescent whitening agents  
©2010 KONICA MINOLTA OPTICS, INC.  
9242-4897-10 BCJEPK 5  
NEW  
XY Automatic Color-Measurement Stage  
Color Management Software  
(Optional accessory)  
+
ColorScoutA3  
(Optional accessory)  
basICColor catch all  
The ColorScoutA3+ enables accurate, high-efficiency  
measurements of color charts with the Spectrodensitometer  
FD-7 and FD-5. It enables  
automatic positioning and  
measurement of the instrument,  
For major efficiency increases in daily color control work.  
Enables color reproduction closer to visual evaluation with simple operation.  
With basICColor catch all, commonly used templates and jobs are already included, so there is no need for measurement preparations such as  
setting target values, tolerances, etc.  
When the software is started, just select the required measurement conditions in the Job Management screen. You can then connect  
immediately to the Spectrodensitometer FD-7 or FD-5, and PDF reports can be created and output automatically.  
providing higher repeatability  
and reducing labor compared  
Data is stored in ISO format (ISO 12642-2), so they can be fed back to profile creation software. Since the FD-7 and FD-5 are the industry's first  
spectrodensitometers to offer M1 measurement condition, color reproduction closer to visual evaluation becomes possible.  
to manual measurements.  
Measure various types of standard color charts to easily check  
whether proof and printed colors are within offset printing standards.  
When the FD-7 is used, scan measurements (which were impossible with conventional  
spectrodensitometers) can be taken, so data from multiple color patches can be obtained in one  
operation.  
XY automatic color-measurement stage.  
Table available with either white surface or black  
surface.  
Pass/Fail judgement results can be seen at a glance.  
Using the ColorScoutA3+ with the FD-7 or FD-5 makes it easier to measure colorimetric data of color  
charts under ISO 13655 Measurement Condition M1. Measurement Condition M1 colorimetric data  
can be used to create color profiles that more closely match visual evaluation.  
Stricter in-house company tolerances or standard tolerance values specified by customers can  
be set and the results of pass/fail judgements based on those tolerances can be easily seen.  
Three-dimensional color solid display enables easy checking of color shifts.  
Target colors can also be created from ICC profiles.  
Maximum measurable chart size of 320 x 460 mm improves measurement efficiency by allowing even  
large color charts to be measured in a single procedure without the need to cut up or tile the charts.  
Measurement of user-designed charts is also possible. The included ColorChart software makes it  
easy to create a definition file for measuring the user-designed chart.  
For ISO 12647-2 printing certification  
checks and print process quality  
management.  
Enables measurement of Fogra and IDEAlliance  
standards and certification checking.  
In addition to CIELAB for color, evaluation results  
for CMYK dot gain and mid-tone spread as  
required for the above certification checking can  
also be easily obtained. This can help discover  
and resolve problems in the printing process at  
an early stage.  
Templates/targets for use with Spectrodensitometer FD-7/FD-5  
Features  
For proof checking Various types of Ugra/Fogra MediaWedge  
Color notations  
CIELAB; CIEXYZ; Density (ISO Status T, ISO Status E, ISO Status A); Dot gain  
Eab (CIE 1976); E94 (CIE 1994; graphics); E94 (CIE 1994; textile); E00  
(CIEDE2000); CMC (l:c); DIN99  
and QA  
CMYK; Various types of IDEAlliance Digital  
Control Strip 2009  
Color-difference  
equations  
Observer  
M
easuremen
t d
a
t
a  
Chart design screen  
For printing  
Various types of FOGRA Stepwedge;  
2°; 10°  
certification and QC IDEAlliance P2P25X  
Main specifications XY Automatic Color-Measurement Stage ColorScoutA3+  
Observation  
illuminants  
Measurement  
conditions  
A; B; C; D50; D55; D65; D75; ID50; ID65; E; F1 to F12  
For CMYK printer  
profile creation  
For RGB printer  
profile creation  
ECI 2002 random; IT8/7-4 random; IT8/7-3  
Measurement range  
(maximum chart size)  
320 x 460 mm  
random; basICColor CMYKick-Target7  
A (ISO 13655 Measurement Condition M0); C; D50 (ISO 13655 Measurement  
Condition M1); D65; ID50; ID65; F2; F6; F7; F8; F9; F10; F11; F12; A+UV cut  
(ISO 13655 Measurement Condition M2); User-defined illuminant  
Calibration; Spot measurement; Scan measurement (With FD-7 only);  
Illumination measurement (With FD-7 only); Job creation/management; Target  
value setting (reference file, ICC profile); Averaging of multiple measurements;  
Graph display; Report output (Pass/Fail message setting)  
Sample ID; CMYK or RGB; CIEXYZ: CIELAB: Density (ISO Status T, ISO  
Status E, ISO Status A); Spectral data (With FD-7 only); Dot gain  
Color tolerance range control; Primary color control; Dot gain control; Mid-tone  
spread control  
TC9.18; Various types of basICColor dropRGB  
Target  
Measuring instrument  
Spectrodensitometer FD-7, FD-5  
6 x 6 mm  
Minimum computing requirements  
Minimum chart patch size  
OS  
Windows® XP SP3 (32-bit); Windows® Vista (32-  
Basic functions  
Maximum sample thickness 1.5 mm  
bit); Windows® 7 (32-bit)  
Intel® Pentium® 4 Processor  
512MB  
Operating temperature/  
humidity range  
10 to 35°C, relative humidity 30 to 85% with no condensation  
CPU  
Memory  
Hard disk  
Display  
Storage temperature/  
humidity range  
-20 to 60°C, relative humidity 0 to 90% with no condensation  
Output items  
At least 100MB of available disk space  
Display unit capable showing at least 1024 x 768  
dots/24-bit color (16 million colors)  
DVD-ROM drive (for installation)  
USB 2.0 port (for instrument connection)  
Microsoft Internet Explorer Ver. 7 or later (to  
obtain license)  
Standard accessories  
Mounting bracket for FD-7, Height adjustment plate, ColorChart software, RS-232C  
cable, USB to RS-232C serial converter, USB cable AC power cord, White calibration  
plate for ColorScoutA3+  
Printing control  
items  
Printing  
standards  
Import/export  
Other  
ISO 12647; FOGRA39, FOGRA27; SWOP; GRACoL  
ColorChart minimum computing requirements  
OS; CPU  
Windows® XP(32-bit), Windows® Vista(32-bit); 300MHz or faster  
Data files: ISO format (ISO 12642-2); PDF report output; Label printing  
English; German; French; Spanish; Italian; Japanese; Chinese (Simplified)  
Hard disk; Memory  
Display  
30MB or more available disk space; 64MB or more  
1024 x 800 pixels or more  
Compatible instruments  
Spectrodensitometer FD-7 and FD-5  
Display  
languages  

Tokina Monofocal Lens TC0812DC User Manual
Sony XS A823 User Manual
Sony WM FX281 User Manual
Sony MEX DV900 User Manual
Sony LCM TRV9 User Manual
Sony HANDYCAM HDR XR500VE User Manual
Sony DVD602 User Manual
Sony DT 55300mm F4556 SAM User Manual
Smith Cast Iron Boilers Series 28A User Manual
Samsung GH68 12948A User Manual