Panasonic WV CW244FE User Manual

Colour CCTV Cameras  
Operating Instructions  
Model No.  
WV-CW240S  
WV-CW244FE  
The model shown is WV-CW244FE.  
Before attempting to connect or operate this product,  
please read these instructions carefully and save this manual for future use.  
We declare under our sole responsibility that the product to which this  
declaration relates is in conformity with the standards or other normative  
documents following the provisions of Directives EEC/73/23 and  
EEC/89/336.  
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT  
CAREFULLY.  
WARNING: This apparatus must be earthed.  
IMPORTANT  
Wij verklaren als enige aansprakelijke, dat het product waarop deze  
verklaring betrekking heeft, voldoet aan de volgende normen of andere  
normatieve documenten, overeenkomstig de bepalingen van Richtlijnen  
73/23/EEC en 89/336/EEC.  
The wires in this mains lead are coloured in accordance with the  
following code.  
Green-and-yellow:  
Earth  
Vi erklærer os eneansvarlige for, at dette produkt, som denne deklaration  
omhandler, er i overensstemmelse med standarder eller andre normative  
dokumenter  
89/336/EEC.  
Blue:  
Brown:  
Neutral  
Live  
i
følge bestemmelserne  
i
direktivene 73/23/EEC og  
As the colours of the wire in the mains lead of this appliance  
may not correspond with the coloured markings identifying the ter-  
minals in your plug, proceed as follows.  
The wire which is coloured green-and-yellow must be con-  
nected to the terminal in the plug which is marked with the letter E  
or by the earth symbol I or coloured green or green-and-  
yellow.  
The wire which is coloured blue must be connected to the ter-  
minal in the plug which is marked with the letter N or coloured  
black.  
The wire which is coloured brown must be connected to the ter-  
minal in the plug which is marked with the letter L or coloured red.  
Vi deklarerar härmed värt fulla ansvar för att den produkt till vilken denna  
deklaration hänvisar är i överensstämmelse med standarddokument, eller  
andra normativa dokument som framstölls i EEC-direktiv nr. 73/23 och  
89/336.  
Ilmoitamme yksinomaisella vastuullamme, että tuote, jota tämä ilmoitus  
koskee, noudattaa seuraavia standardeja tai muita ohjeellisia asiakirjoja,  
jotka noudattavat direktiivien 73/23/EEC ja 89/336/EEC säädöksiä.  
Vi erklærer oss alene ansvarlige for at produktet som denne erklæringen  
gjelder for, er  
i
overensstemmelse med følgende normer eller andre  
normgivende dokumenter som følger bestemmelsene i direktivene 73/23/  
EEC og 89/336/EEC.  
-3-  
CONTENTS  
FEATURES .....................................................................................................................................................................  
PREFACE .......................................................................................................................................................................  
PRECAUTIONS ..............................................................................................................................................................  
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ........................................................................................  
5
5
6
7
INSTALLATION .............................................................................................................................................................. 10  
I Installation Plans & Preparations ............................................................................................................................. 10  
I Mounting the Camera .............................................................................................................................................. 12  
I Connections ............................................................................................................................................................ 14  
I Image Adjustment ................................................................................................................................................... 16  
SPECIFICATIONS .......................................................................................................................................................... 18  
STANDARD ACCESSORIES .......................................................................................................................................... 19  
OPTIONAL ACCESSORIES ............................................................................................................................................ 20  
OPTIONAL HEATER UNIT ............................................................................................................................................. 21  
I Optional Heater Unit WV-CW3HE ........................................................................................................................... 21  
-4-  
PREFACE  
The WV-CW240 series is a 1/3” CCD colour camera  
designed for use in a video surveillance system. The  
camera features a high picture quality thanks to the use  
of digital signal processing LSIs, and easy installation.  
FEATURES  
• Mounting method: Flush mounting/WV-CW244FE,  
Surface mounting/WV-CW240S  
• Signal processing: Automatic Light Control (ALC),  
Automatic Gain Control (AGC), Automatic Tracing  
White Balance (ATW), etc.  
• Synchronization: Internal, Line-Lock, (only when  
24 V AC or 220 V - 240 V AC supplied) and  
Multiplexed Vertical Drive (VD2)  
• Minimum illumination: 1.0 lx (0.1 foot-candle) at  
WIDE  
• Signal-to-noise ratio: 50 dB (Equivalent to AGC  
OFF)  
• Horizontal resolution: 480 TV lines  
• Optional heater unit available for the camera used  
at temperatures between –10°C and –30°C (14°F  
and –22°F).  
-5-  
PRECAUTIONS  
1. This product should be installed and connected by  
qualified service personnel or system installers in  
conformity with local codes.  
7. Clean the lens faceplate with care.  
Do not clean the lens with strong or abrasive deter-  
gents. Use lens tissue or a cotton tipped applicator  
and ethanol.  
2. Use a class 2 power source supplying 12 V DC or  
24 V AC.  
8. Never face the camera towards the sun.  
Do not aim the camera at bright objects. Whether  
the camera is in use or not, never aim it at the sun  
or other extremely bright objects. Otherwise,  
blooming or smear may be caused.  
3. To prevent fire or electric shock hazard, use a UL  
listed cable (VW-1, style 1007) to connect the  
power supply to the camera. (WV-CW244FE)  
4. Be sure to use a ceiling board/wall having enough  
9. Do not operate the camera beyond its specifica-  
tions.  
strength to support this camera.  
Use the camera under conditions where tempera-  
ture is between –10°C to +50°C (14°F to 122°F),  
and humidity is below 90 %. The input power  
source for WV-CW240S is 220 V - 240 V 50 Hz, and  
for WV-CW244FE is 24 V AC 50 Hz or 12 V DC.  
5. Handle the camera with care.  
Do not abuse the camera. Avoid striking, shaking,  
etc. The camera could be damaged by improper  
handling or storage.  
6. Do not use strong or abrasive detergents.  
Use a dry cloth to clean the camera body when  
dirty.  
10. Use a monitor whose resolution is at least equal to  
that of the camera.  
In case the dirt is hard to remove, use a mild deter-  
gent and wipe gently. Afterwards, wipe off the  
remaining detergent with a dry cloth.  
-6-  
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS  
q w  
2nd transport protection screw (Red)  
Space for heater unit  
!
OFF  
ON  
e
r
t
SYNC LL  
INT*  
ON  
BLC  
AP  
OFF*  
SOFT SHARP*  
* Default setting  
!
o
i
u y  
q Focus lock lever  
e Zoom lock lever  
Fixes the focus position after adjusting.  
Fixes the zoom position after adjusting.  
w Tilting lock screw  
r Panning table  
Fixes the tilting position after adjusting.  
Adjusts the panning angle of the camera.  
-7-  
t Azimuth adjuster  
! Heater power connector  
Adjusts the azimuth angle to obtain a level image.  
Supplies power to the optional heater unit when it is  
built in the camera. Connect here a harness stick-  
ing out from the heater unit.  
y Pan lock screw  
Fixes the panning position after adjusting.  
u Video jack (3.5-diam. mini jack)  
For connecting an LCD monitor to adjust the cam-  
era images. Use an L-type plug to save space.  
i Aperture Level Selector  
SHARP: Sharpens the image outline.  
SOFT: Softens the image outline.  
The default setting is SHARP.  
o Back Light Compensation Selector  
ON: Compensates the background if it is brighter  
than the object.  
OFF: Does not compensate.  
The default setting is OFF.  
! Synchronization Mode Selector  
Specifies a source for synchronization.  
INT: Internal 2:1 interlace.  
LL: Line-lock mode driven by 24 V AC or 220 V-240  
V AC.  
The default setting is INT.  
Note: Do not set the switch to LL (Line-Lock) posi-  
tion when supplying 12 V DC to avoid synchro-  
nization error.  
-8-  
!
!
2
3
Dome cover  
Video output cable with BNC connector  
Connects with the video connector of the monitor.  
!2  
!
4
Camera power cable  
For WV-CW240S: Supplies 220 V - 240 V AC 50 Hz  
to the camera. The camera will supply the  
optional heater unit with 24 V AC power that is  
transformed from the supplied 220 V - 240 V  
AC.  
!3  
For WV-CW244FE: Supplies 24 V AC 50 Hz or 12  
V DC to the camera. The black and grey cords  
will supply 24 V AC to the optional heater unit  
from an external power source.  
!4  
!
!
5
Camera attachment  
!5  
6
Camera mounting bracket  
Only WV-CW240S (surface mount type) is supplied  
with a mounting bracket for ceiling installation.  
!8  
!
!
7
8
Cable access hole  
Sideway cable exit  
!6  
!7  
-9-  
INSTALLATION  
1. Space  
Prepare a space larger than ø160 mm.  
I Installation Plans & Preparations  
G WV-CW244FE  
2. Flush-mount hole  
“F” stands for flush mounting. This model can be  
installed on the wall or ceiling prepared with a 95 mm  
diameter hole.  
Drill a hole having a 95 mm diameter on the wall or  
ceiling.  
3. Attachment fixing screws  
74 mm  
(2-15/16")  
Locally procure four screws (M4) that are suitable  
for the installation surface to fix the attachment on  
the surface.  
4. Cable route  
Cables will go behind the wall or ceiling.  
5. Waterproof Process  
When necessary, apply waterproof process to the  
camera and relevant portions.  
Camera lock screw  
Attachment fixing screw x4  
(procured locally)  
-10-  
G WV-CW240S  
“S” stands for surface mounting. This model can be installed on the surface of the wall or ceiling using the supplied  
bracket.  
Cable access hole  
for 3/4" pipe  
Bracket center  
Bracket fixing screw x4 (procured locally)  
Camera lock screw  
Attachment fixing screw x4 (supplied)  
-11-  
1. Space  
Prepare a space larger than ø160 mm.  
I Mounting the Camera  
G Disassembling of the camera  
2. Bracket Fixing Screws  
To fix the bracket, procure four M4 screws suitable  
for the surface and structure of the wall/ceiling.  
1. Remove the dome cover by loosening three tamp-  
er-proof screws using the supplied bit.  
3. Attachment Fixing Screws  
Four screws are supplied as standard accessories.  
4. Cable route  
• When routing cables through the wall/ceiling, drill a  
hole as shown in the figure.  
• When routing cables sideway, open the sideway  
cable exit unscrewing the lid by use of a hexagon  
wrench. Screw the detached lid to the cable  
access hole on the bottom of the bracket.  
5. Waterproof Process  
When necessary, apply waterproof process to the  
camera and relevant portions.  
-12-  
2. Remove the two red-coloured screws provided for  
transport protection using a Philips screwdriver.  
G Mounting the camera  
1. Fix the camera to the installation surface.  
WV-CW244FE  
• Fix the attachment on the surface using four  
screws (locally procured).  
2nd transport  
protection screw (Red)  
• Place the camera on the attachment and rotate  
it clockwise.  
• Fasten the camera lock screw.  
WV-CW240S  
• Fix the bracket on the surface using four  
screws (locally procured).  
• Fix the attachment on the bracket using four  
screws (supplied).  
• Place the camera on the attachment and rotate  
it clockwise.  
• Fasten the camera lock screw.  
G Heater unit installation  
See OPTIONAL HEATER UNIT for details.  
2. Perform connections referring to I Connections.  
Adhesive tape  
Fold  
Supplied screw  
Harness  
3. Reinstall the camera to the bracket or attachment  
referring to step 1 above.  
4. Adjust the image referring to I Image Adjustment.  
5. Apply waterproof means referring to G Waterproof  
Process.  
Point A”  
(inside the wall)  
-13-  
Caution: Be sure to connect the GND (grounding) lead  
of the camera and grounding terminal of the power  
supply when using a 24 V AC power source.  
I Connections  
G Video Output Connection  
Connect the video output connector to the monitor or  
other system device with the procured coaxial cable.  
The maximum extensible length is shown in the table.  
12 V DC (WV-CW244FE)  
Wire colour  
Brown  
Function  
Note  
Type of coaxial  
cable  
RG-59/U  
(3C-2V)  
RG-6/U  
(5C-2V)  
RG-11/U RG-15/U  
12 V DC Positive  
For camera  
(7C-2V)  
(10C-2V)  
Blue  
12 V DC Negativee 265 mA  
(m)  
(ft)  
250  
825  
500  
600  
800  
Recommended  
maximum  
cable length  
Green/Yellow Not used  
1 650  
1 980  
2 640  
Black  
Grey  
24 V AC Live  
24 V AC Neutral  
For optional heater  
12.1 W  
G
Wire colours & functions  
24 V AC (WV-CW244FE)  
220 - 240 V (WV-CW240S)  
Wire colour  
Brown  
Function  
Note  
For camera  
Wire colour  
Brown  
Function  
Note  
24 V AC Live  
220-240 V AC Live 4.1 W (camera)  
220-240 V AC Neutral 13 W (with heater)  
Blue  
24 V AC Neutral 3.0 W  
Blue  
Green/Yellow GND  
Green/Yellow GND  
Black  
Grey  
24 V AC Live  
For optional heater  
24 V AC Neutral 12.1 W  
Caution: See page 3 for mains lead connection.  
-14-  
G
10.5 V DC VA 2(R x I x L) 16 V DC  
L : Cable length (m) (ft)  
R : Resistance of copper wire (/m) (/ft)  
VA : DC output voltage of power supply unit  
Cable Length and Wire Gauge  
24 V AC  
The recommended cable length and thickness are  
shown in the table for reference. The voltage sup-  
plied to the power terminals of the camera should  
be within 19.5 V AC and 28 V AC.  
I
: DC current consumption (A). See specifica-  
tions.  
Recommended wire gauge for 24 V AC line.  
Copper wire size  
(AWG)  
#24  
#22  
#20  
#18  
2
2
2
2
(0.22 mm ) (0.33 mm ) (0.52 mm ) (0.83 mm )  
(m)  
(ft)  
95  
150  
495  
255  
842  
425  
Length of  
Cable  
(Approx.)  
314  
1 403  
12 V DC  
Use the formula below to calculate the power cable  
and power supply. The voltage supplied to the  
power terminals of the camera should be within  
10.5 V DC and 16 V DC.  
Resistance of copper wire [at 20 °C (68 °F)]  
Copper wire size  
(AWG)  
#24  
#22  
#20  
#18  
2
2
2
2
(0.22 mm ) (0.33 mm ) (0.52 mm ) (0.83 mm )  
Resistance /m  
0.078  
0.026  
0.050  
0.017  
0.03  
0.018  
0.006  
Resistance /ft  
0.010  
-15-  
1. Connect an LCD monitor to the video jack.  
I Image Adjustment  
You can manually adjust the pan/tilt/azimuth angles,  
focus, and zoom while observing the connected moni-  
tor.  
2. Pan/tilt/azimuth adjustment  
• Loosen the two screws locking the pan and tilt  
tables.  
• Pan and tilt the table to aim the camera at what you  
need to watch.  
• Turn the azimuth adjuster to obtain a level image.  
• Tighten the two screws after adjusting.  
Variable angles  
plus or minus 75 °  
(max.)  
Pan lock screw  
(stainless)  
Tilting lock screw  
(stainless)  
Panning table  
Azimuth adjuster  
Notes:  
• Do not hold the camera by lens unit to adjust pan-  
ning, tilting, or azimuth.  
• The video output to the BNC will be interrupted  
while an LCD monitor is connected to the video  
jack.  
-16-  
3. Zoom  
G Waterproof Process  
When necessary, apply waterproof process to protect  
the camera from water soak.  
Using butyl rubber tapes is recommended, not using  
ordinary vinyl tapes.  
• Unlock the zoom lever.  
• Move the lever to adjust the zoom.  
• Lock the lever.  
1. Power cord  
First, tape the individual wires, finally all of them as  
a whole.  
FAR  
TELE  
NEAR  
WIDE  
Power cord  
Zoom lock lever  
Focus lock lever  
2. Connector junctions  
Tape the BNC-BNC junction point.  
4. Focus  
Video output cable  
• Unlock the focus lever.  
• Move the lever to adjust the focus.  
• Lock the lever.  
5. Reinstalling the dome cover  
• Attach the dome cover to the camera.  
• Tighten the three tamper-proof screws.  
-17-  
SPECIFICATIONS  
Pick-up device:  
Scanning area:  
Scanning:  
752 (H) x 582 (V) pixels, Interline transfer CCD  
4.8 (H) x 3.6 (V) mm (Equivalent to 1/3” pick-up tube)  
625 lines/50 fields/25 frames  
15.625 kHz  
Horizontal:  
Vertical:  
Synchronization:  
50 Hz  
Internal, Line-lock (only 24 V AC or 220-240 V AC), or Multiplexed vertical drive  
(VD2)  
Video output:  
1.0 V [P-P] PAL composite 75 /BNC connector  
480 lines  
50 dB (Equivalent to AGC Off, weight On)  
1.0 lx (0.1 footcandle) (WIDE),  
SHARP or SOFT, selectable  
ATW  
Horizontal resolution:  
Signal-to-noise ratio:  
Minimum illumination:  
Detail:  
White balance:  
Lens Mount:  
CS-mount  
Lens  
Focal length:  
3.8 mm - 8 mm  
Maximum aperture ratio:  
Angular field of view:  
1:1.4 (Wide), 1:1.8 (Tele)  
Horizontal: 35.6° - 73.6°  
Vertical:  
26.6° - 53.4°  
Focusing range:  
Ambient operating temperature:  
1.2 m - (3.9 ft - )  
–10°C - +50°C (14°F - 122°F)  
–30°C - +50°C (–22°F - 122°F)  
(When the optional heater unit built in)  
Less than 90 %  
Ambient operating humidity:  
Power source and  
Power consumption:  
WV-CW244FE: 12 V DC, 265 mA (Camera)  
24 V AC 50 Hz, 3.0 W (Camera)  
24 V AC 50 Hz, 12.1 W (Heater unit)  
-18-  
WV-CW240S: 220 V - 240 V AC 50 Hz  
4.1 W (Camera)  
13 W (with heater)  
WV-CW244FE: 160.5 mm (H) 154 mm (D)  
6-5/16" (H) 6-1/16" (D)  
WV-CW240S: 161 mm (H) 160 mm (D)  
6-3/8" (H) 6-5/16" (D)  
WV-CW244FE: 1.4 kg (3.1 lbs.)  
Dimensions:  
Weights:  
WV-CW240S: 2.1 kg (6.4 lbs.)  
Weights and dimensions indicated are approximate.  
Specifications are subject to change without notice.  
STANDARD ACCESSORIES  
Operating Instructions (this document) ............................................. 1 pc.  
The following are for installation.  
Attachment ........................................................................................ 1 pc.  
Tamperproof screw bit ...................................................................... 1 pc.  
Camera mounting bracket (supplied only to WV-CW240S)............... 1 pc.  
Attachment fixing screw (supplied only to WV-CW240S) ................. 4 pcs.  
-19-  
OPTIONAL ACCESSORIES  
Heater unit ......................................................................................... WV-CW3HE  
-20-  
OPTIONAL HEATER UNIT  
I Optional Heater Unit WV-CW3HE  
G Introduction  
Installing this heater unit enables the camera to operate under in a low-temperature environment of –30°C (–22°F).  
The heater turns on automatically when the temperature inside the camera drops below +10°C (50°F) and turns off  
when it rises.  
A small fan inside the unit will minimize condensation on the surface of the dome cover caused by changes in ambi-  
ent temperature unless temperatures change too rapidly. The fan will stop when there is no possibility of condensa-  
tion.  
G Precautions  
• This product should be installed and connected by qualified service personnel or system installers.  
• Do not use the same 24 V AC power source supplying the power to the camera for the heater unit. Connect  
another 24 V AC power source to the heater unit. If the same power source is used, turning the heater on and off  
may disturb the camera images.  
• When servicing, pay attention to high temperature on the surface of the unit. Disconnect the harness and wait  
until it cools.  
• When you install the camera in a low-temperature location and start operating it, it may take time (around 30 min-  
utes) for the inside of the camera to warm up. Cut power once then supply power again.  
-21-  
G Installation  
Adhesive tape  
Fold  
Supplied screw  
Harness  
1. Open the dome cover. (See Disassembling the  
camera.)  
2. Place the heater unit in the camera and fix it with  
the supplied screw.  
3. Insert the harness into the heater unit connector of  
the camera.  
4. Fold the desiccant pack in half, and attach it with  
adhesive tape to point "A" shown in the figure.  
Note: Attach the desiccant pack so that it does not  
block ventilation holes or hang over the top of  
the wall.  
5. Attach the dome cover while paying attention not to  
pinch the harness cable.  
Point A”  
(inside the wall)  
6. Connect the heater power cable of the camera. (See Connection.)  
G Specifications  
Required power:  
Power consumption:  
Dimensions:  
24 V AC, 50 Hz  
12.1 W maximum  
29 mm (H) x 83 mm (W) x 89.5 mm (D)  
[1-1/8" (H) x 3-1/4" (W) x 3-1/2" (D)]  
45 g (0.1 lbs.)  
Weights:  
G Accessories  
Fixing screw (M3 x 12) ...................................1 pc.  
Desiccant pack .............................................1.pc.  
-22-  
Printed in China  
Gedruckt in China  
Imprimé en Chine  
Impreso en China  
Stampato in Cina  
2003 © Matsushita Electric Industrial Co., Ltd. All rights reserved.  
Ns1103-0 3TR002014AAA  

Radio Shack PLWV104 2R User Manual
Philips SA6085 User Manual
Pentax TS4V214ED (C70223) User Manual
Pelco Camera Accessories EH4014 User Manual
Panasonic CQ DFX883U User Manual
Panasonic CQ C3301N User Manual
Panasonic AJ YA350G User Manual
Kenwood EZ500 User Manual
JVC LYT0002 073A User Manual
JVC KS FX555 User Manual