York H Rd036 Thru 060 User Manual

254892-YTG-C-0606  
DESCRIPTION  
The 13 SEER Series condensing unit is the outdoor part of a  
versatile system of air conditioning. It is designed to be cus-  
tom-matched with one of UPG’s complete line of evaporator  
sections, with each serving a specific function. Matching Air  
Handlers are available for upflow, downflow, or horizontal  
applications to provide a complete system. Electric Heaters  
are available, if required. Add-On coils are available for use  
with upflow, downflow, or horizontal furnaces and air han-  
dlers.  
TECHNICAL GUIDE  
WARRANTY  
5-year limited parts warranty.  
5-year limited compressor warranty.  
SPLIT-SYSTEM  
AIR CONDITIONERS  
FEATURES  
13 SEER – R-22  
QUALITY CONDENSER COILS - The coil is constructed  
of copper tube and aluminum fins.  
MODELS:  
H*RD018 THRU 060  
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)  
PROTECTED COMPRESSOR - The compressor is inter-  
nally protected against high pressure and temperature.  
This is accomplished by the simultaneous operation of  
high pressure relief valve and a temperature sensor which  
protects the compressor if undesirable operating condi-  
tions occur. A liquid line filter-drier further protects the  
compressor.  
DURABLE FINISH - The cabinet is made of pre-painted  
steel. The pre-treated galvanized steel provides a better  
paint to steel bond, which resists corrosion and rust creep.  
Special primer formulas and matted-textured finish insure  
less fading when exposed to sunlight.  
H*RD036 THRU 060  
(2.5 THRU 5 NOMINAL TONS, 3 PHASE)  
LOWER INSTALLED COST - Installation time and costs  
are reduced by easy power and control wiring connec-  
tions. Discharge line heat exchanger knockouts are pro-  
vided, if required. Available in sweat connect models only.  
The unit contains enough refrigerant for matching indoor  
coils and 15 feet of interconnecting piping. The small base  
dimension means less space is required on the ground or  
roof.  
TOP DISCHARGE - The warm air from the top mounted  
fan is blown up away from the structure and any landscap-  
ing. This allows compact location on multi-unit applica-  
tions.  
LOW OPERATING SOUND LEVEL - The upward air flow  
carries the normal operating noise away from the living  
area. The rigid top panel effectively isolates any motor  
sound. Isolator mounted compressor and the rippled fins  
of the condenser coil muffle the normal fan motor and  
compressor operating sounds.  
R
P
CERTIFICATION APPLIES ONLY  
WHEN THE COMPLETE  
SYSTEM IS LISTED  
WITH ARI.  
LOW MAINTENANCE - Long life permanently lubricated  
motor-bearings need no annual servicing.  
EASY SERVICE ACCESS - Fully exposed refrigerant con-  
nections, a single panel covering the electrical controls,  
and the molex plug in the control box connecting the con-  
denser fan make for easy servicing of the unit.  
SECURED SERVICE VALVES - Secured re-usable ser-  
vice valves are provided on both the liquid and vapor  
sweat connections for ease of evacuating and charging.  
ISO 9001  
Certified Quality  
Management System  
LISTED  
Due to continuous product improvement, specifications  
are subject to change without notice.  
U.L. and C.U.L. listed - approved for outdoor application.  
Certified in accordance with the Unitary Small Equipment cer-  
tification program, which is based on ARI Standard 210/240.  
Additional rating information can be found at  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
254892-YTG-C-0606  
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase  
Outdoor Unit  
H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06  
Required TXV  
1TVM2A1  
4 - 9  
1TVM2(A,B)1  
6 - 3  
1TVM2A1  
5 - 13  
1TVM2A1  
6 - 0  
1TVM2C1  
8 - 13  
1TVM2C1  
8 - 6  
1TVM2C1  
10 - 2  
Factory R-22 Charge, lbs-oz  
Indoor Coil1,2  
TXV KIT3 - Additional Charge, Oz  
FC/MC/PC/UC/UC18A2A  
FC/MC/PC/UC18B2A  
FC/MC/PC/UC24A2A  
FC/MC/PC/UC24B2A  
FC/MC/PC/UC30A2A  
FC/MC/PC/UC30B2A  
FC/MC/PC/UC36A2A  
FC/MC/PC/UC36B2A  
FC/MC/PC/UC36C2A  
FC/MC/PC/UC42B2C  
FC/MC/PC/UC42C2C  
FC/MC/PC/UC48C2C  
FC/MC/PC/UC48D2C  
FC/PC/UC/UC60C2C  
FC/MC/PC/UC60D2C  
MC61D2C  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
HC18A2A  
HC30A2A  
0
HC36B2A  
HC42C2C  
HC60C2C  
HD24A2A  
0
HD36B2A  
HD48C2C  
HD60D2C  
AHP18B2A  
AHP24B2A  
0
AHP30B2A  
0
AHP36C2A  
AHP42C2C  
AHP/SHP48D2C  
AHP/SHP60D2C  
AV24B2A  
0
AV36C2A  
0
0
0
0
AV/SV48D2C  
AV/SV60D2C  
FC/MC/PC/UC18A3X  
FC/MC/PC/UC18B3X  
FC/MC/PC/UC24A3X  
FC/MC/PC/UC24B3X  
FC/MC/PC/UC30A3X  
FC/MC/PC/UC30B3X  
FC/MC/PC/UC36A3X  
FC/MC/PC/UC36B3X  
FC/MC/PC/UC36C3X  
FC/MC/PC/UC42B3X  
FC/MC/PC/UC42X3X  
FC/MC/PC/UC48C3X  
FC/MC/PC/UC48D3X  
FC/PC/UC/UC60C3X  
FC/MC/PC/UC60D3X  
MC61D3X  
2B + 1  
2B + 1  
2A + 0  
2A + 0  
2A + 0  
2A + 0  
For Notes See Page 5.  
Unitary Products Group  
3
254892-YTG-C-0606  
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)  
Outdoor Unit  
H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06  
Required TXV  
1TVM2A1  
4 - 9  
1TVM2(A,B)1  
6 - 3  
1TVM2A1  
5 - 13  
1TVM2A1  
6 - 0  
1TVM2C1  
8 - 13  
1TVM2C1  
8 - 6  
1TVM2C1  
10 - 2  
Factory R-22 Charge, lbs-oz  
Indoor Coil1,2  
HC18A3X  
TXV KIT3 - Additional Charge, Oz  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2B + 1  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
HC30A3X  
2A + 0  
HC36B3X  
HC42C3X  
HC60C3X  
HD24A3X  
2A + 0  
HD36B3X  
HD48C3X  
HD60D3X  
AHP18B3X  
AHP24B3X  
2A + 0  
AHP30B3X  
2A + 0  
AHP36C3X  
AHP42C3X  
AHP/SHP48D3X  
AHP/SHP60D3X  
AV24B3X  
2A + 0  
AV36C3X  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AV/SV48D3X  
AV/SV60D3X  
G2FD024(S,H)14,17  
G2FD030(S,H)17  
G2FD035(S,H)14  
G2FD036(S,H)17  
G2FD036(S,H)21  
G2FD042(S,H)21  
G2FD046(S,H)17  
G2FD048(S,H)21,24  
G2FD060(S,H)24  
G2FD061H24  
G1HA024H14  
G1HA036H14  
G1HA036H17  
G1HA048H21  
G1HA060H24  
G1HD036  
2B + 1  
2B + 1  
2B + 1  
2A + 0  
2B + 1  
2A + 0  
2A + 0  
2A + 0  
G1HD048  
G1HD060  
G1NA030S17K  
G1NA030S21M  
G1NA036S17J  
G1NA036S21C  
G1NA036S17L  
G1NA042S24W  
G1NA048S21D  
G1NA060S24T  
G1FA/G1UA030S14  
G1FA/G1UA036S14  
G1FA/G1UA036S17,21  
G1FA/G1UA048S17  
G1FA/G1UA048S21  
G1FA/G1UA060S21,24  
F2RP/F2FP024  
F2RP/F2FP030  
F2RP/F2FP036  
For Notes See Page 5.  
2B + 1  
2B + 1  
2A + 0  
2A + 0  
2A + 0  
2A + 0  
2B + 1  
2A + 0  
2B + 1  
2B + 1  
2A + 0  
4
Unitary Products Group  
254892-YTG-C-0606  
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)  
Outdoor Unit  
H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06  
Required TXV  
1TVM2A1  
4 - 9  
1TVM2(A,B)1  
6 - 3  
1TVM2A1  
5 - 13  
1TVM2A1  
6 - 0  
1TVM2C1  
8 - 13  
1TVM2C1  
8 - 6  
1TVM2C1  
10 - 2  
Factory R-22 Charge, lbs-oz  
Indoor Coil1,2  
TXV KIT3 - Additional Charge, Oz  
F2RP/F2FP040  
F2FP048  
0
0
0
0
0
0
1
0
1
1
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0*  
0
0
0
0*  
0
0
0
0
0
0
0
F2FP060  
F2FV060  
G4FA030S14T2A  
G4FA030S14T2B  
G4FA036S14T2A  
G4FA036S17T2A  
G4FA036S21T2A  
G4FA036S21T2B  
G4FA048S17T2A  
G4FA048S17T2C  
G4FA048S21T2A  
G4FA048S21T2C  
G4FA060S21T2C  
G4FA060S24T2C  
G4FD024H14T2A  
G4FD024H14T2B  
G4FD024H17T2A  
G4FD024H17T2B  
G4FD030H17T2A  
G4FD035H14T2A  
G4FD036H17T2A  
G4FD036H21T2A  
G4FD042H21T2A  
G4FD042H21T2C  
G4FD046H17T2A  
G4FD046H17T2C  
G4FD048H21T2A  
G4FD048H21T2C  
G4FD048H24T2A  
G4FD048H24T2C  
G4FD060H24T2C  
G4FD061H24T2C  
F4FP024H06T2A  
F4FP024H06T2B  
F4FP030H06T2A  
F4FP036H06T2A  
F4FP040H06T2A  
F4FP042H06T2A  
F2FP048H06T2C  
F2FP060H06T2C  
F2FV060H06T2C  
FOOTNOTES:  
0
0
0
0
0
0
0
0
0
1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.  
2. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.  
3. A TXV kit must be used with these coils to obtain system performance (2A, 2B, and 2C indicate 1TVM series).  
* This loose coil match does not achieve 13 SEER.  
PROCEDURES:  
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of inter-  
connecting  
line tubing.  
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.  
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.  
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for  
evaporator + adder for line set.  
Unitary Products Group  
5
254892-YTG-C-0606  
PHYSICAL AND ELECTRICAL DATA - 3 PHASE  
H1RD  
H1RD  
H1RD  
H1RD  
H1RD  
H1RD  
H1RD  
H1RD  
H1RD  
H1RD  
MODEL  
030S25 036S25 042S25 048S25 060S25 030S46 036S46 042S46 048S46 060S46  
Unit Supply Voltage  
208-230V, 3φ, 60Hz  
460V, 3φ, 60Hz  
Normal Voltage Range 1  
Minimum Circuit Ampacity  
187 to 252  
432 to 504  
14.3  
20  
14.3  
12.4  
20  
21.5  
23.1  
40  
6.9  
15  
15  
9.6  
15  
15  
6.9  
15  
15  
10.3  
15  
11.3  
15  
Max. Overcurrent Device Amps 2  
Min. Overcurrent Device Amps 3  
Compressor Type 4  
20  
15  
35  
25  
15  
15  
25  
15  
15  
Recip  
10.2  
72  
Recip  
10.2  
72  
Recip  
8.8  
ScrollB ScrollB  
Recip  
4.9  
Recip  
13.5  
45  
Recip  
11.8  
45  
ScrollB ScrollB  
Rated Load  
Compressor Amps  
16.0  
115  
No  
17.3  
123  
No  
7.7  
50  
8.4  
70  
Locked Rotor  
72  
45  
Crankcase Heater  
No  
No  
No  
No  
No  
No  
No  
No  
Fan Motor Amps  
Fan Diameter Inches  
Rated HP  
Rated Load  
1.5  
1.5  
1.5  
1.5  
1.5  
0.7  
0.7  
0.7  
0.7  
0.7  
22  
22  
22  
22  
24  
22  
22  
22  
24  
24  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
Fan Motor  
Nominal RPM  
Nominal CFM  
Face Area Sq. Ft.  
Rows Deep  
850  
3100  
15.72  
1
850  
3150  
15.72  
1
850  
3550  
23.60  
1
850  
3550  
24.00  
1
850  
3600  
27.00  
1
850  
3100  
15.72  
1
850  
3150  
15.72  
1
850  
3550  
23.60  
1
850  
3550  
24.00  
2
850  
3600  
27.00  
2
Coil  
Fin / Inches  
22  
22  
22  
22  
22  
22  
22  
22  
18  
18  
Liquid Line Set OD (Field Installed)  
Vapor Line Set OD (Field Installed)  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/4  
7/8  
7/8  
7/8  
1-1/8  
10 - 2  
0.76  
294  
3/4  
7/8  
7/8  
7/8  
1-1/8  
10 - 2  
0.76  
294  
Unit Charge (Lbs. - Oz.) 5  
Charge Per Foot, Oz.  
Operating Weight Lbs.  
5 - 13  
0.68  
208  
6 - 0  
0.70  
208  
8 - 13  
0.70  
208  
8 - 6  
0.70  
215  
5 - 13  
0.68  
208  
6 - 0  
0.70  
208  
8 - 13  
0.70  
215  
8 - 6  
0.70  
250  
1. Rated in accordance with ARI Standard 110, utilization range “A”.  
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.  
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.  
4. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.  
5. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than  
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.  
All dimensions are in inches. They are subject to change  
without notice. Certified dimensions will be provided upon  
request.  
DIMENSIONS  
C
Unit  
Model  
Dimensions  
(Inches)  
Refrigerant Connection  
Service Valve Size  
A1  
27  
27  
39  
34  
38  
B
C
Liquid  
Vapor  
3/4”  
030  
036  
042  
048  
060  
37  
37  
37  
43  
43  
27  
27  
27  
32  
32  
A
3/8”  
7/8”  
7/8”*  
1. Including Fan Guard.  
* Adapter fitting required for 1-1/8” line set.  
B
6
Unitary Products Group  
254892-YTG-C-0606  
Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase  
Outdoor Unit  
H1RD030S(25,46)  
H1RD036S(25,46)  
H1RD042S(25,46)  
H1RD048S(25,46)  
H1RD060S(25,46)  
Required TXV  
1TVM2A1  
1TVM2A1  
1TVM2C1  
1TVM2C1  
1TVM2C1  
Factory R-22 Charge, lbs-oz  
5 - 13  
6 - 0  
8 - 13  
8 - 6  
10 - 2  
Indoor Coil1  
Additional Charge, Oz  
FC/MC/PC/UC30A2A  
FC/MC/PC/UC30B2A  
FC/MC/PC/UC36A2A  
FC/MC/PC/UC36B2A  
FC/MC/PC/UC36C2A  
FC/MC/PC/UC42B2C  
FC/MC/PC/UC42C2C  
FC/MC/PC/UC48C2C  
FC/MC/PC/UC48D2C  
FC/PC/UC/UC60C2C  
FC/MC/PC/UC60D2C  
MC61D2C  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
HC30A2A  
HC36B2A  
HC42C2C  
HC60C2C  
HD36B2A  
HD48C2C  
0
HD60D2C  
AHP30B2A  
AHP36C2A  
AHP42C2C  
0
0
0
0
0
0
0
0
0
0
0
0
AHP/SHP48D2C  
AHP/SHP60D2C  
FC/MC/PC/UC30A3X  
FC/MC/PC/UC30B3X  
FC/MC/PC/UC36A3X  
FC/MC/PC/UC36B3X  
FC/MC/PC/UC36C3X  
FC/MC/PC/UC42B3X  
FC/MC/PC/UC43X3X  
FC/MC/PC/UC48C3X  
FC/MC/PC/UC48D3X  
FC/PC/UC/UC60C3X  
FC/MC/PC/UC60D3X  
MC61D3X  
HC30A3X  
HC36B3X  
HC42C3X  
HC60C3X  
HD36B3X  
HD48C3X  
HD60D3X  
AHP30B3X  
AHP36C3X  
AHP42C3X  
AHP/SHP48D3X  
AHP/SHP60D3X  
For Notes See Page 8.  
Unitary Products Group  
7
254892-YTG-C-0606  
Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase (Continued)  
Outdoor Unit  
H1RD030S(25,46)  
H1RD036S(25,46)  
H1RD042S(25,46)  
H1RD048S(25,46)  
H1RD060S(25,46)  
Required TXV  
1TVM2A1  
1TVM2A1  
1TVM2C1  
1TVM2C1  
1TVM2C1  
Factory R-22 Charge, lbs-oz  
5 - 13  
6 - 0  
8 - 13  
8 - 6  
10 - 2  
Indoor Coil1  
Additional Charge, Oz  
G4FA036S14T2A  
G4FA048S17T2A  
G4FA048S17T2C  
G4FA048S21T2A  
G4FA048S21T2C  
G4FA060S21T2C  
G4FA060S24T2C  
G4FD036H17T2A  
G4FD036H21T2A  
G4FD042H21T2A  
G4FD042H21T2C  
G4FD046H17T2A  
G4FD046H17T2C  
G4FD048H21T2C  
G4FD048H24T2C  
G4FD060H24T2C  
G4FD061H24T2C  
F4FP040H06T2A  
F4FP042H06T2A  
F2FP048H06T2C  
FOOTNOTES:  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.  
PROCEDURES:  
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of inter-  
connecting  
line tubing.  
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.  
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.  
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for  
evaporator + adder for line set.  
8
Unitary Products Group  
254892-YTG-C-0606  
COOLING CAPACITY - With Air Handler Coils  
AIR HANDLER  
COOLING  
NET MBH  
UNIT  
MODEL  
COIL MODEL1  
ELECTRIC  
RATED  
CFM  
MODEL  
W
SEER EER  
HEAT KW2  
TOTAL  
SENS.  
1 & 3 PH 13 SEER AC WITH MA  
MA08B  
MA08B  
MA08B  
MA08B  
MA12B  
MA12B  
MA12B  
MA12B  
MA12B  
MA12B  
MA12B  
MA12B  
MA12B  
MA12B  
MA16C  
MA16C  
MA14D  
MA16C  
MA16C  
MA14D  
MA16C  
MA16C  
MA14D  
MA16C  
MA16C  
MA14D  
MA16C  
MA16C  
MA20D  
MA20D  
MA16C  
MA16C  
MA20D  
MA20D  
MA20D  
MA20D  
MA20D  
MA20D  
MA20D  
MA20D  
MA20D  
MA20D  
2,5,8  
2,5,8  
2,5,8  
2,5,8  
5,8,10  
5,8,10  
5,8,10  
10  
10  
10  
5,8,10  
5,8,10  
10  
17  
17  
17  
17  
17  
17  
17  
17  
17  
17  
17  
17  
17  
17  
21  
21  
24  
21  
21  
24  
21  
21  
24  
21  
21  
24  
21  
21  
24  
24  
21  
21  
24  
24  
24  
24  
24  
24  
24  
24  
24  
24  
FC/MC18B  
G*FD024H17  
FC/MC24B  
G*FD024H17  
FC/MC30B  
FC/MC36B  
G*FD036H17  
FC/MC30B  
FC/MC36B  
G*FD036H17  
FC/MC36B  
G*FD036H17  
FC/MC36B  
G*FD036H17  
FC/MC42C  
FC/MC48C  
FC/MC48D  
G*FD042H21  
G*FD048H21  
G*FD048H24  
FC/MC42C  
FC/MC48C  
FC/MC48D  
G*FD042H21  
G*FD048H21  
G*FD048H24  
FC/MC48C  
G*FD048H21  
FC/MC48D  
G*FD048H24  
FC/MC48C  
G*FD048H21  
FC/MC48D  
G*FD048H24  
FC/MC60D  
G*FD060H24  
G*FD061H24  
MC61D  
600  
600  
800  
800  
17.5  
17.5  
23.0  
23.0  
29.6  
29.6  
29.6  
29.0  
29.0  
29.0  
34.8  
34.8  
34.5  
34.5  
40.5  
41.0  
41.0  
40.5  
41.0  
41.0  
39.5  
40.0  
40.0  
39.5  
40.0  
40.0  
47.0  
47.0  
47.0  
47.0  
46.0  
46.0  
46.0  
46.0  
55.0  
55.0  
55.5  
55.5  
54.5  
55.0  
54.5  
55.0  
11.7  
11.7  
16.6  
16.6  
21.0  
21.3  
21.3  
20.9  
20.9  
20.9  
25.4  
25.4  
25.2  
25.2  
29.6  
30.2  
30.2  
29.6  
30.2  
30.2  
29.6  
30.2  
30.2  
29.6  
30.2  
30.2  
35.7  
35.7  
35.1  
35.1  
34.4  
34.4  
34.4  
34.4  
39.6  
39.6  
40.0  
40.0  
39.3  
39.3  
39.3  
39.3  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
H2RD018S06  
H2RD024S06  
1000  
1000  
1000  
1000  
1000  
1000  
1200  
1200  
1200  
1200  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1600  
1600  
1600  
1600  
1600  
1600  
1600  
1600  
1600  
1600  
1800  
1800  
1600  
1600  
1800  
1800  
H2RD030S06  
H1RD030S(25,46)  
H2RD036S06  
H1RD036S(25,46)  
10  
5,8,10,15,18  
5,8,10,15,18  
5,8,10,15,18  
5,8,10,15,18  
5,8,10,15,18  
5,8,10,15,18  
10,15,18  
10,15,18  
10,15,18  
10,15,18  
10,15,18  
10,15,18  
5,8,10,15,18  
5,8,10,15,18  
8,10,15,20,25  
8,10,15,20,25  
10,15,18  
10,15,18  
10,15,18,20  
10,15,18,20  
5,8,10,15,20,25  
5,8,10,15,20,25  
5,8,10,15,20,25  
5,8,10,15,20,25  
10,15,18,20  
10,15,18,20  
10,15,18,20  
10,15,18,20  
H2RD042S06  
H1RD042S(25,46)  
H2RD048S06  
H1RD048S(25,46)  
H2RD060S06  
FC/MC60D  
G*FD060H24  
G*FD061H24  
MC61D  
H1RD060S(25,46)  
1 PH 13 SEER AC WITH MV - VARIABLE SPEED  
MV12B  
MV12B  
MV12B  
MV12B  
MV12B  
MV12B  
MV16C  
MV12B  
MV16C  
MV16C  
MV16C  
MV20D  
MV16C  
MV20D  
MV20D  
MV20D  
5,8,10,15  
5,8,10,15  
5,8,10,15  
5,8,10,15  
5,8,10,15  
17  
17  
17  
17  
17  
17  
21  
17  
21  
21  
21  
24  
21  
24  
24  
24  
FC/MC18B  
FC/MC24B  
FC/MC24B  
FC/MC30B  
FC/MC30B  
FC/MC36B  
FC/MC36C  
FC/MC36B  
FC/MC36C  
FC/MC42C  
FC/MC48C  
FC/MC48D  
FC/MC48C  
FC/MC48D  
FC/MC60D  
MC61D  
600  
600  
800  
17.7  
18.0  
23.4  
23.4  
30.0  
30.0  
30.0  
35.0  
35.2  
40.5  
41.5  
41.5  
47.0  
47.0  
54.0  
55.5  
11.7  
11.8  
16.5  
16.6  
21.0  
21.2  
21.2  
25.0  
25.2  
29.1  
29.7  
29.8  
34.7  
34.6  
38.6  
39.1  
14.00 11.50  
14.00 11.50  
14.00 11.50  
14.00 11.50  
14.00 11.50  
14.00 11.50  
14.00 11.50  
13.50 11.00  
14.00 11.50  
13.75 11.00  
14.00 11.50  
14.00 11.50  
13.50 11.00  
13.50 11.00  
13.00 11.00  
13.25 11.00  
H2RD018S06  
H2RD024S06  
800  
1000  
1000  
1000  
1200  
1200  
1400  
1400  
1400  
1600  
1600  
1800  
1800  
H2RD030S06  
H2RD036S06  
H2RD042S06  
H2RD048S06  
5,8,10,15  
5,8,10,15,18,20  
5,8,10,15  
5,8,10,15,18,20  
5,8,10,15,18,20  
5,8,10,15,18,20  
8,10,15,18,20,25  
5,8,10,15,18,20  
8,10,15,18,20,25  
8,10,15,18,20,25  
8,10,15,18,20,25  
H2RD060S06  
For Notes See Page 10.  
Unitary Products Group  
9
254892-YTG-C-0606  
COOLING CAPACITY - With Air Handler Coils (Continued)  
AIR HANDLER  
COOLING  
NET MBH  
UNIT  
MODEL  
COIL MODEL1  
ELECTRIC  
RATED  
CFM  
MODEL  
W
SEER EER  
HEAT KW2  
TOTAL  
SENS.  
1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED  
H2RD018S06  
H2RD024S06  
H2RD030S06  
AV24  
AV24  
AV36  
2,5,8,10,15  
2,5,8,10,15  
5,8,10,15,18  
17  
17  
21  
21  
24  
24  
24  
24  
600  
800  
18.0  
23.2  
30.0  
35.2  
35.8  
40.5  
47.0  
55.0  
11.7  
16.5  
21.2  
25.0  
25.0  
29.1  
34.7  
39.1  
14.00 11.50  
14.00 11.50  
14.00 11.50  
14.00 11.50  
13.75 11.00  
14.00 11.50  
13.50 11.00  
13.15 11.00  
1000  
1200  
1200  
1400  
1600  
1800  
AV36  
5,8,10,15,18  
H2RD036S06  
AV/SV48  
AV/SV48  
AV/SV48  
AV/SV60  
5,8,10,15,18,20,25  
5,8,10,15,18,20,25  
5,8,10,15,18,20,25  
5,8,10,15,18,20,25  
H2RD042S06  
H2RD048S06  
H2RD060S06  
1 & 3 PH 13 SEER AC WITH AHP / F*FP / F*FV  
AHP18  
AHP24  
F*FP024  
AHP24  
2,5,8  
2,5,8,10  
5,8,10  
2,5,8,10  
5,8,10  
5,8,10  
5,8,10,15  
5,8,10  
17  
17  
17  
17  
17  
17  
17  
17  
17  
21  
17  
17  
21  
17  
21  
24  
21  
17  
21  
24  
24  
21  
24  
24  
24  
21  
24  
24  
24  
24  
24  
24  
24  
24  
24  
24  
24  
650  
655  
650  
830  
795  
17.7  
17.9  
17.5  
23.0  
23.6  
23.0  
23.0  
30.0  
30.0  
29.6  
29.7  
29.7  
29.3  
35.0  
35.0  
36.0  
34.8  
34.7  
34.7  
35.7  
34.5  
41.0  
42.0  
40.5  
41.0  
40.0  
41.0  
39.5  
40.0  
47.5  
47.0  
47.0  
46.0  
46.0  
55.0  
55.0  
54.0  
12.3  
12.5  
12.2  
16.8  
17.0  
16.8  
16.8  
21.9  
22.6  
21.3  
21.7  
22.4  
21.1  
27.2  
27.5  
26.7  
25.4  
27.0  
27.3  
26.5  
25.2  
31.0  
30.7  
33.2  
31.0  
30.3  
30.0  
32.5  
30.3  
36.9  
36.8  
36.2  
36.1  
35.5  
40.3  
40.3  
39.6  
13.00 11.00  
13.50 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.00 11.00  
13.50 11.00  
13.00 11.00  
13.00 11.00  
13.50 11.00  
13.00 11.00  
13.50 11.00  
13.50 11.00  
14.00 11.50  
13.00 11.00  
13.50 11.00  
13.50 11.00  
14.00 11.50  
13.00 11.00  
13.00 11.00  
13.50 11.00  
14.00 11.50  
13.00 11.00  
13.00 11.00  
13.50 11.00  
14.00 11.50  
13.00 11.00  
13.50 11.00  
13.00 11.00  
13.75 11.00  
13.00 11.00  
13.75 11.00  
13.20 11.00  
13.00 11.00  
13.00 11.00  
H2RD018S06  
H2RD024S06  
AHP30  
F*FP024  
F*FP030  
AHP30  
AHP36  
F*FP036  
AHP30  
AHP36  
F4FP036  
AHP36  
800  
800  
1015  
1040  
1000  
1015  
1040  
1000  
1235  
1255  
1200  
1200  
1235  
1255  
1200  
1200  
1485  
1400  
1400  
1400  
1485  
1400  
1400  
1400  
1600  
1675  
1600  
1675  
1600  
1850  
1850  
1850  
H2RD030S06  
5,8,10,15,18  
5,8,10,15,19  
5,8,10  
5,8,10,15,18  
5,8,10,15,19  
5,8,10,15,18  
5,8,10,15,18  
5,8,10,15,20,25  
5,8,10,15  
5,8,10,15,18  
5,8,10,15,18  
5,8,10,15,20,25  
5,8,10,15  
5,8,10,15,18  
5,8,10,15,20  
5,8,10,15,20,25  
5,8,10,15  
5,8,10,15,18  
5,8,10,15,20  
5,8,10,15,20,25  
5,8,10,15  
5,8,10,15,20,25  
5,8,10,15,20  
5,8,10,15,20,25  
5,8,10,15,20  
5,8,10,15,20,25  
5,8,10,15,20,25  
5,8,10,15,20,25  
5,8,10,15,20,25  
H1RD030S(25,46)  
AHP42  
H2RD036S06  
H1RD036S(25,46)  
H2RD042S06  
AHP/SHP60  
F*FP040  
AHP36  
AHP42  
AHP/SHP60  
F*FP040  
AHP42  
AHP/SHP48  
AHP/SHP60  
F*FP048  
AHP42  
AHP/SHP48  
AHP/SHP60  
F4FP048  
F*FV060  
AHP/SHP48  
AHP/SHP60  
AHP/SHP48  
AHP/SHP60  
F*FV060  
AHP/SHP60  
AHP/SHP60  
H1RD042S(25,46)  
H2RD048S06  
H1RD048S(25,46)  
H2RD060S06  
H1RD060S(25,46)  
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.  
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.  
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.  
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power  
input in watt-hours during the same period.  
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.  
2. Single phase units require single phase 2HK heaters.  
— = Not applicable.  
10  
Unitary Products Group  
254892-YTG-C-0606  
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils  
FURNACE**  
COOLING  
COIL  
MODEL  
NET MBH  
UNIT MODEL  
CFM RANGE  
(MIN.-MAX.)  
RATED  
CFM  
W
SEER1  
EER  
TOTAL  
17.5  
17.7  
17.7  
17.5  
17.5  
17.5  
17.5  
18.0  
23.0  
23.0  
23.0  
23.0  
23.0  
23.0  
23.0  
23.4  
23.4  
23.4  
29.6  
29.6  
29.6  
29.6  
29.6  
29.6  
30.0  
30.0  
29.0  
29.0  
29.0  
29.0  
29.0  
29.0  
29.0  
29.0  
34.8  
34.8  
34.8  
34.8  
35.0  
34.8  
35.0  
36.0  
34.5  
34.5  
34.5  
34.5  
34.7  
34.5  
34.7  
35.7  
SENS.  
11.7  
11.9  
11.9  
11.7  
11.7  
11.7  
11.7  
12.1  
16.6  
16.6  
16.6  
16.6  
16.6  
16.6  
16.6  
16.9  
16.9  
17.2  
21.0  
21.3  
21.0  
21.3  
21.3  
21.6  
21.9  
22.0  
20.9  
20.9  
20.9  
20.9  
20.9  
20.9  
20.9  
20.9  
25.4  
25.4  
25.4  
25.4  
25.4  
25.4  
25.6  
26.6  
25.2  
25.2  
25.2  
25.2  
25.2  
25.2  
25.4  
26.4  
14,17  
14,17  
14  
FC/MC/PC/UC18  
FC/MC/PC/UC24  
G*FA030S14  
G*FD024H14,17  
G*FD030H17  
G*FD035H14  
HC24  
600  
600  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.50  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.50  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
600  
14,17  
17  
600  
450  
750  
H2RD018S06  
600  
14  
600  
14  
600  
HD24  
600  
14,17  
14,17  
17,21  
14  
FC/MC/PC/UC24  
FC/MC/PC/UC30  
G*FA030S14  
G*FA036S17  
G*FD024H14,17  
G*FD030H17  
G*FD035H14  
G*FD036H17  
HC30  
800  
800  
800  
800  
14,17  
17  
800  
600  
1000  
H2RD024S06  
800  
14  
800  
17  
800  
14  
800  
HD24  
800  
14,17  
14,17,21  
14  
FC/MC/PC/UC30  
FC/MC/PC/UC36  
G*FA036S14  
G*FD036H17  
G*FD036H21  
HC30  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
17  
800  
1200  
H2RD030S06  
21  
14  
17  
HC36  
-
HD36  
14,17  
14,17,21  
14  
FC/MC/PC/UC30  
FC/MC/PC/UC36  
G*FA030S14  
G*FD036H17  
G*FD036H21  
HC30  
17  
800  
1200  
H1RD030S(25,46)  
21  
14  
17  
HC36  
-
HD36  
14,17,21  
17  
FC/MC/PC/UC36  
G*FA042S17  
G*FD036H17  
G*FD036H21  
G*FD042H21  
G*FD046H17  
HC36  
17  
21  
1000  
1400  
H2RD036S06  
21  
17  
17  
HD36  
14,17,21  
17  
FC/MC/PC/UC36  
G*FA042S17  
G*FD036H17  
G*FD036H21  
G*FD042H21  
G*FD046H17  
HC36  
17  
21  
1000  
1400  
H1RD036S(25,46)  
21  
17  
17  
HD36  
For Notes See Page12.  
Unitary Products Group  
11  
254892-YTG-C-0606  
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued)  
FURNACE**  
COOLING  
COIL  
MODEL  
NET MBH  
UNIT MODEL  
CFM RANGE  
(MIN.-MAX.)  
RATED  
CFM  
W
SEER1  
EER  
TOTAL  
40.5  
41.0  
40.5  
41.0  
40.5  
40.5  
41.0  
41.0  
41.5  
39.5  
40.0  
39.5  
40.0  
39.5  
39.5  
40.0  
40.0  
40.5  
47.0  
47.0  
46.5  
47.0  
46.0  
46.0  
46.0  
45.5  
46.0  
55.0  
55.0  
55.0  
55.5  
55.5  
55.0  
55.0  
54.5  
54.5  
54.5  
54.5  
55.0  
54.5  
54.5  
SENS.  
29.6  
30.2  
29.6  
29.6  
29.6  
29.6  
30.2  
29.9  
29.5  
28.9  
29.5  
28.9  
28.9  
28.9  
28.9  
29.5  
29.2  
28.8  
35.1  
35.1  
35.0  
34.8  
34.4  
34.4  
34.4  
34.3  
34.1  
39.6  
39.6  
39.6  
39.6  
40.0  
39.6  
39.9  
39.3  
39.3  
39.3  
39.3  
39.7  
39.3  
39.6  
17,21  
21,24  
17  
FC/MC/PC/UC42  
FC/MC/PC/UC48  
G*FA042S17  
G*FA048S21  
G*FD042H21  
G*FD046H17  
G*FD048H21,24  
HC48  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1600  
1600  
1600  
1600  
1600  
1600  
1600  
1600  
1600  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
1800  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
21  
21  
1200  
1600  
H2RD042S06  
17  
21,24  
21  
HD48  
17,21  
21,24  
17  
FC/MC/PC/UC42  
FC/MC/PC/UC48  
G*FA042S17  
G*FA048S21  
G*FD042H21  
G*FD046H17  
G*FD048H21,24  
HC48  
21  
1200  
1600  
H1RD042S(25,46)  
21  
17  
21,24  
21  
-
HD48  
21,24  
21,24  
21  
FC/MC/PC/UC48  
G*FD048H21,24  
HC48  
1400  
1800  
H2RD048S06  
HD48  
21,24  
21,24  
21,24  
21  
FC/MC/PC/UC48  
G*FA048S21  
G*FD048H21,24  
HC48  
1400  
1800  
H1RD048S(25,46)  
HD48  
21,24  
21,24  
24  
FC/MC/PC/UC60  
G*FA060S21,24  
G*FD060H24  
G*FD061H24  
MC61  
1600  
2000  
H2RD060S06  
24  
24  
24  
HC60  
HD60  
21,24  
21,24  
24  
FC/MC/PC/UC60  
G*FA060S21,24  
G*FD060H24  
G*FD061H24  
MC61  
1600  
2000  
H1RD060S(25,46)  
24  
24  
24  
HC60  
HD60  
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.  
** Refer to Quick Selection Chart for specific furnace match-up.  
12  
Unitary Products Group  
254892-YTG-C-0606  
COOLING CAPACITY - With Variable Speed Furnaces  
COOLING  
NET MBH  
TOTAL SENS.  
VARIABLE SPEED  
FURNACE MODEL  
COIL  
UNIT MODEL  
W
MODEL1  
RATED  
CFM  
SEER  
EER  
1 PH 13 SEER AC WITH VARIABLE SPEED FURNACES2  
PV8*A12  
PV9*A12  
FC/MC/PC18A  
FC/MC/PC18A  
FC/MC/PC18B  
FC/MC/PC24A  
FC/MC/PC24A  
FC/MC/PC24B  
HC24  
14  
14  
17  
14  
14  
17  
14  
14  
600  
600  
17.8  
17.8  
17.8  
18.0  
18.0  
18.0  
17.8  
17.8  
18.0  
18.0  
23.2  
23.4  
23.2  
23.2  
23.2  
23.4  
23.2  
23.2  
23.6  
23.6  
23.8  
23.8  
30.0  
30.0  
29.8  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
11.9  
11.8  
11.8  
12.1  
12.0  
12.0  
11.9  
11.8  
12.2  
12.2  
16.7  
16.8  
16.7  
16.7  
16.8  
16.8  
16.8  
16.8  
17.1  
17.0  
17.3  
17.3  
21.1  
21.4  
21.1  
21.1  
21.5  
21.6  
21.6  
21.6  
21.5  
21.5  
21.5  
21.5  
21.7  
21.7  
22.1  
22.0  
22.1  
22.2  
22.3  
22.3  
22.1  
22.2  
22.2  
22.2  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
13.50  
14.00  
13.50  
13.50  
13.50  
14.00  
14.00  
14.00  
13.50  
13.75  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
14.00  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.00  
11.50  
11.00  
11.00  
11.00  
11.50  
11.50  
11.50  
11.00  
11.00  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
11.50  
P(C,V)9*B12  
PV8*A12  
600  
600  
PV9*A12  
600  
H2RD018S06  
P(C,V)9*B12  
PV8*A12  
600  
600  
PV9*A12  
HC24  
600  
PV8*A12  
HD24  
600  
PV9*A12  
HD24  
600  
PV8*A12  
FC/MC/PC24A  
FC/MC/PC24B  
FC/MC/PC24A  
FC/MC/PC24B  
FC/MC/PC30A  
FC/MC/PC30B  
FC/MC/PC30A  
FC/MC/PC30B  
HC30  
14  
17  
14  
17  
14  
17  
14  
17  
14  
14  
800  
PV8*B16  
800  
PV9*A12  
800  
P(C,V)9*B12  
PV8*A12  
800  
800  
PV8*B16  
800  
H2RD024S06  
PV9*A12  
800  
P(C,V)9*B12  
PV8*A12  
800  
800  
PV9*A12  
HC30  
800  
PV8*A12  
HD24  
800  
PV9*A12  
HD24  
800  
PV8*A12  
FC/MC/PC30A  
FC/MC/PC30B  
FC/MC/PC30A  
FC/MC/PC30B  
FC/MC/PC36A  
FC/MC/PC36B  
FC/MC/PC36C  
FC/MC/PC36C  
FC/MC/PC36A  
FC/MC/PC36B  
FC/MC/PC36C  
FC/MC/PC36C  
HC30  
14  
17  
14  
17  
14  
17  
21  
21  
14  
17  
21  
21  
14  
14  
17  
17  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
PV8*B16  
PV9*A12  
P(C,V)9*B12  
PV8*A12  
PV8*B16  
PV8*C16  
PV8*C20  
PV9*A12  
P(C,V)9*B12  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*A12  
H2RD030S06  
PV9*A12  
HC30  
PV8*B16  
HC36  
P(C,V)9*B12  
PV8*A12  
HC36  
HD36  
PV8*B16  
HD36  
PV8*C16  
PV8*C20  
PV9*A12  
HD36  
HD36  
HD36  
P(C,V)9*B12  
P(C,V)9*C16  
P(C,V)9*C20  
HD36  
HD36  
HD36  
For Notes See Page15.  
Unitary Products Group  
13  
254892-YTG-C-0606  
COOLING CAPACITY - With Variable Speed Furnaces (Continued)  
COOLING  
NET MBH  
TOTAL SENS.  
VARIABLE SPEED  
FURNACE MODEL  
COIL  
UNIT MODEL  
W
MODEL1  
RATED  
CFM  
SEER  
EER  
1 PH 13 SEER AC WITH VARIABLE SPEED FURNACES2  
PV8*A12  
PV8*B16  
FC/MC/PC36A  
FC/MC/PC36B  
FC/MC/PC36C  
FC/MC/PC36C  
FC/MC/PC36A  
FC/MC/PC36B  
FC/MC/PC36C  
FC/MC/PC36C  
G1FA048S17  
G2FD036(S,H)17  
G2FD036(S,H)17  
G2FD036(S,H)21  
G2FD036(S,H)21  
G2FD036(S,H)21  
G2FD036(S,H)21  
G2FD046(S,H)17  
HC36  
14  
17  
21  
21  
14  
17  
21  
21  
17  
17  
17  
21  
21  
21  
21  
17  
17  
17  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1200  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
1400  
35.0  
35.2  
35.2  
35.2  
34.8  
35.0  
35.2  
35.2  
34.6  
34.6  
34.6  
34.6  
34.6  
34.6  
34.6  
34.6  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
36.0  
40.5  
40.5  
40.5  
41.5  
41.5  
41.5  
41.5  
41.5  
41.0  
41.5  
41.0  
41.0  
42.0  
42.0  
42.0  
42.0  
42.0  
25.4  
25.6  
25.6  
25.6  
25.4  
25.5  
25.6  
25.6  
25.1  
25.1  
25.1  
25.1  
25.1  
25.1  
25.1  
25.1  
26.6  
26.5  
26.7  
26.8  
26.8  
26.8  
26.7  
26.7  
26.8  
26.8  
29.7  
29.7  
29.7  
30.1  
30.1  
30.1  
30.1  
30.1  
30.0  
30.1  
30.0  
30.1  
30.6  
30.6  
30.5  
30.6  
30.5  
13.00  
13.75  
14.00  
14.00  
13.00  
13.25  
13.75  
14.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
13.00  
14.00  
13.75  
13.50  
14.00  
14.00  
14.00  
13.50  
14.00  
14.00  
14.00  
13.50  
13.50  
13.50  
13.75  
14.00  
13.50  
13.75  
13.50  
13.50  
13.75  
13.50  
13.75  
14.00  
14.00  
13.75  
14.00  
14.00  
11.00  
11.00  
11.50  
11.50  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.50  
11.50  
11.50  
11.00  
11.50  
11.50  
11.50  
11.00  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.50  
11.50  
11.00  
11.50  
11.50  
PV8*C16  
PV8*C20  
PV9*A12  
P(C,V)9*B12  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*B16  
PV8*B16  
P(C,V)9*B12  
PV8*C16  
PV8*C20  
H2RD036S06  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*B16  
PV8*B16  
P(C,V)9*B12  
PV8*A12  
HC36  
HD36  
PV8*B16  
HD36  
PV8*C16  
HD36  
PV8*C20  
HD36  
PV9*A12  
HD36  
P(C,V)9*B12  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*B16  
HD36  
HD36  
HD36  
FC/MC/PC42B  
FC/MC/PC42C  
FC/MC/PC42C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48D  
HC48  
17  
21  
21  
21  
21  
21  
21  
24  
21  
21  
21  
21  
PV8*C16  
PV8*C20  
PV8*C16  
PV8*C20  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C16  
H2RD042S06  
PV8*C20  
HC48  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*C16  
HC48  
HC48  
HD48  
PV8*C20  
HD48  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
HD48  
HD48  
HD48  
For Notes See Page15.  
14  
Unitary Products Group  
254892-YTG-C-0606  
COOLING CAPACITY - With Variable Speed Furnaces (Continued)  
COOLING  
NET MBH  
TOTAL SENS.  
VARIABLE SPEED  
FURNACE MODEL  
COIL  
UNIT MODEL  
W
MODEL1  
RATED  
CFM  
SEER  
EER  
1 PH 13 SEER AC WITH VARIABLE SPEED FURNACES2  
PV8*C16  
PV8*C20  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48D  
HC48  
21  
21  
21  
21  
24  
21  
21  
21  
21  
1500  
1600  
1600  
1600  
1600  
1500  
1600  
1600  
1600  
1500  
1600  
1600  
1600  
1600  
1730  
1620  
1620  
1730  
1620  
1620  
1730  
1620  
1730  
1620  
1620  
46.5  
47.0  
47.0  
47.0  
47.0  
46.5  
47.0  
46.5  
46.5  
47.0  
47.0  
47.0  
47.0  
47.0  
54.0  
54.5  
54.5  
55.0  
54.0  
55.0  
54.0  
54.5  
55.0  
54.5  
54.0  
34.2  
35.2  
35.2  
35.2  
35.2  
33.9  
35.0  
35.0  
35.0  
34.6  
35.8  
35.7  
35.7  
35.8  
38.9  
37.9  
37.9  
39.3  
38.0  
38.1  
38.9  
37.9  
39.1  
38.0  
38.1  
13.00  
13.00  
13.00  
13.00  
13.25  
13.00  
13.00  
13.00  
13.00  
13.25  
13.50  
13.00  
13.25  
13.50  
13.00  
13.00  
13.25  
13.00  
13.00  
13.25  
13.00  
13.25  
13.00  
13.00  
13.25  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C16  
PV8*C20  
HC48  
H2RD048S06  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*C16  
HC48  
HC48  
HD48  
PV8*C20  
HD48  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C20  
HD48  
HD48  
HD48  
FC/PC60C  
FC/PC60C  
FC/MC/PC60D  
MC61  
21  
21  
24  
24  
24  
24  
24  
24  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C20  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C20  
MC61  
H2RD060S06  
MC61  
HC60  
P(C,V)9*D20  
PV8*C20  
HC60  
HD60  
P(C,V)9*C20  
P(C,V)9*D20  
HD60  
HD60  
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.  
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.  
Unitary Products Group  
15  
254892-YTG-C-0606  
1H/1C, auto/manual changeover, electronic programmable,  
deluxe 7-day, thermostat.  
ACCESSORIES  
Refer to Price Manual for specific model numbers.  
1H/1C, auto/manual changeover, electronic programmable.  
HARD START KIT - Provides increased starting torque for  
areas with low voltage.  
* For the most current accessory information, refer to the  
price book or consult factory.  
COMPRESSOR BLANKET - Designed to further reduce the  
normal compressor operating sound. Refer to price pages for  
specific match-ups.  
SOUND POWER RATINGS*  
UNIT MODEL  
(dBA)  
75  
018  
024  
030  
036  
042  
048  
060  
OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle  
to prevent rapid recycling of the compressor.  
74  
75  
ROOM THERMOSTATS - A wide selection of compatible  
thermosets are available to provide optimum performance  
and features for any installation.  
75  
76  
76  
1H/1C, manual change-over electronic non-programmable  
thermostat.  
76  
* Rated in accordance with ARI 270-95 Standards.  
TYPICAL INSTALLATION  
MINIMUM 24” SERVICE ACCESS  
CLEARANCE ON ONE SIDE  
THERMOSTAT  
TO FURNACE OR  
AIR HANDLER  
TERMINAL BLOCK  
60” OVERHEAD  
CLEARANCE  
WEATHERPROOF  
DISCONNECT  
SWITCH  
NEC CLASS 1 WIRING  
NEC CLASS 2 WIRING  
10” CLEARANCE  
COIL AREA  
TO INDOOR COIL  
SEAL OPENING(S) WITH  
PERMAGUM OR EQUIVALENT  
NOTE: ALL OUTDOOR WIRING  
MUST BE WEATHERPROOF.  
CONTROL ACCESS PANEL  
TYPICAL FIELD WIRING - 1 Phase Application  
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES  
POWER WIRING  
CONTROL WIRING  
FACTORY WIRING  
POWER WIRING  
208/230-1-60  
24 VOLT CONTROL WIRING  
MINIMUM 18 GA. WIRE  
(NEC CLASS 2)  
FURNACE OR AIR HANDLER TERMINAL BLOCK  
Y R G W  
C
*
TERMINAL W IS ONLY  
REQUIRED ON SYSTEMS  
WITH HEAT.  
CONTACTOR  
TERMINALS  
GND.  
LUG  
*
COIL  
R
Y
G
W
ROOM THERMOSTAT  
CONDENSING UNIT  
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.  
16  
Unitary Products Group  
254892-YTG-C-0606  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
H2RD018S06  
INDOOR COIL MODEL NO.  
FC/MC/PC/UC18  
IDCFM  
450  
600  
75  
750  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F) 80  
ID WB (°F) 57  
80  
62  
75  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
T.C.  
S.C.  
KW  
15.4 17.8 18.0 21.0 22.6 17.3 18.9 18.8 21.1 22.6 19.2 19.9 19.5 21.2 22.7  
15.1 13.5 11.8 12.2 9.6 17.0 15.8 13.2 13.3 10.0 18.9 18.2 14.5 14.4 10.5  
65  
75  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
T.C.  
S.C.  
KW  
14.6 16.8 16.8 19.4 21.2 16.3 17.6 17.4 19.6 21.3 17.9 18.4 18.0 19.8 21.4  
14.4 13.0 11.1 11.5 9.1 16.0 15.1 12.5 12.6 9.5 17.6 17.2 13.8 13.6 10.0  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
1.1  
T.C.  
S.C.  
KW  
13.9 15.8 15.5 17.9 19.9 15.3 16.4 16.0 18.1 19.9 16.6 17.0 16.6 18.3 20.0  
13.7 12.5 10.5 10.7 8.6 15.0 14.3 11.7 11.8 9.0 16.4 16.1 13.0 12.9 9.4  
85  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
1.2  
T.C.  
S.C.  
KW  
13.2 14.7 14.2 16.4 18.5 14.3 15.1 14.7 17.5 18.6 15.3 15.5 15.1 16.8 18.7  
95  
13.0 12.0 9.8  
1.2 1.3 1.3  
9.9  
1.3  
8.1 14.1 13.6 11.0 11.7 8.5 15.1 15.1 12.3 12.1 8.9  
1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3  
T.C.  
S.C.  
KW  
12.3 13.5 13.1 15.2 17.1 13.2 13.9 13.4 15.3 17.1 14.1 14.2 13.8 15.4 17.1  
105  
115  
125  
12.1 11.5 9.3  
1.3 1.3 1.3  
9.5  
1.4  
7.5 13.0 12.7 10.5 10.5 8.0 13.9 13.9 11.7 11.6 8.4  
1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4  
T.C.  
S.C.  
KW  
11.4 12.3 12.0 14.0 15.7 12.1 12.7 12.2 14.0 15.6 12.8 13.0 12.5 13.9 15.5  
11.2 11.0 8.8  
1.4 1.4 1.4  
9.1  
1.4  
7.0 11.9 11.9 10.0 10.1 7.4 12.6 12.7 11.2 11.1 7.8  
1.5 1.4 1.4 1.4 1.5 1.5 1.5 1.5 1.4 1.5 1.5  
T.C.  
S.C.  
KW  
10.5 11.1 10.9 12.8 14.3 11.0 11.4 11.0 12.6 14.1 11.6 11.7 11.2 12.5 13.9  
10.3 10.5 8.4  
1.5 1.5 1.5  
8.6  
1.5  
6.5 10.9 11.1 9.5  
1.6 1.5 1.5 1.5  
9.6  
1.5  
6.9 11.4 11.6 10.7 10.6 7.3  
1.6 1.6 1.6 1.5 1.6 1.6  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
Coil  
T.C.  
1.00  
1.01  
1.00  
1.01  
1.01  
1.02  
1.00  
1.01  
1.03  
1.03  
1.01  
1.00  
1.03  
1.00  
1.01  
1.00  
1.00  
1.00  
1.00  
S.C.  
1.00  
1.02  
1.00  
1.02  
1.05  
1.07  
1.04  
1.00  
1.01  
1.01  
1.02  
1.00  
1.03  
1.00  
1.02  
1.00  
1.00  
1.00  
1.00  
KW  
1.00  
1.01  
1.00  
1.01  
1.01  
1.02  
1.00  
0.97  
0.98  
0.98  
1.01  
1.00  
1.03  
1.00  
1.01  
1.00  
1.00  
1.00  
1.00  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
MA08B  
MC18B  
PV8*A12  
PV9*A12  
P(C,V)9*B12  
PV8*A12  
PV9*A12  
P(C,V)9*B12  
PV8*A12  
PV9*A12  
PV8*A12  
PV9*A12  
FC/MC/PC18A  
FC/MC/PC18A  
FC/MC/PC18B  
FC/MC/PC24A  
FC/MC/PC24A  
FC/MC/PC24B  
HC24  
1.02  
1.02  
1.02  
1.03  
1.03  
1.03  
1.02  
1.02  
1.03  
1.03  
1.02  
1.01  
1.01  
1.03  
1.03  
1.03  
1.02  
1.01  
1.04  
1.04  
0.97  
0.97  
0.97  
0.98  
0.98  
0.98  
0.97  
0.97  
0.98  
0.98  
MA08B  
MC24B  
MA08B  
G*FD024H17  
G*FD030H17  
MA08B  
AHP18  
AHP24  
F*FP024  
MV12B  
FC/MC18B  
FC/MC24B  
HC24  
MV12B  
HD24  
AV24  
HD24  
FC/MC/PC/UC24  
HC24  
HD24  
G*FA030S14  
G*FA036S14  
G*FA036S17,21  
G*FD024H14,17  
G*FD030H17  
G*FD035H14  
Unitary Products Group  
17  
254892-YTG-C-0606  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
H2RD024S06  
INDOOR COIL MODEL NO.  
FC/MC/PC/UC24  
IDCFM  
600  
800  
75  
1000  
75  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F) 80  
ID WB (°F) 57  
80  
62  
75  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
62  
62  
T.C.  
S.C.  
KW  
21.8 23.8 23.8 25.7 28.3 24.1 25.1 25.1 26.8 29.8 21.8 26.5 26.5 28.0 31.3  
21.8 19.5 15.2 16.6 13.6 24.1 23.0 17.6 19.1 15.6 20.4 26.4 19.9 21.6 17.5  
1.60 1.62 1.62 1.65 1.67 1.70 1.71 1.71 1.73 1.75 1.60 1.79 1.79 1.81 1.84  
20.4 21.9 21.9 24.2 26.4 21.4 23.6 23.6 25.3 27.7 22.5 25.3 25.3 26.3 29.0  
20.4 18.6 14.2 16.1 13.0 21.4 21.8 16.4 18.7 14.9 22.1 25.0 18.5 21.3 16.8  
1.71 1.72 1.72 1.77 1.79 1.77 1.82 1.82 1.85 1.88 1.83 1.91 1.91 1.94 1.97  
19.0 20.0 20.0 22.7 24.5 21.6 22.1 22.1 23.8 25.7 23.2 24.1 24.1 24.7 26.8  
18.7 17.6 13.3 15.5 12.3 21.2 20.6 15.2 16.6 14.2 23.2 23.6 17.1 21.0 16.0  
1.81 1.82 1.82 1.88 1.92 1.93 1.93 1.93 1.98 2.01 2.05 2.04 2.04 2.06 2.11  
17.6 18.1 18.1 21.2 22.6 20.8 20.5 20.5 22.1 23.6 23.9 22.9 22.9 23.1 24.6  
17.6 16.7 12.3 15.0 11.7 20.3 19.4 14.0 17.8 13.5 23.9 22.2 15.7 20.7 15.3  
1.92 1.92 1.92 2.00 2.04 2.09 2.04 2.04 2.09 2.14 2.27 2.16 2.16 2.19 2.25  
19.3 17.0 17.0 19.3 21.1 20.3 18.8 18.8 20.2 22.0 21.2 20.7 20.7 21.1 22.9  
19.3 16.0 11.7 14.2 11.2 20.3 18.2 12.8 16.8 13.1 21.2 20.5 14.0 19.4 14.9  
2.10 2.01 2.01 2.10 2.16 2.21 2.14 2.14 2.20 2.26 2.32 2.28 2.28 2.30 2.37  
15.4 15.8 15.8 17.4 19.6 17.0 17.2 17.2 18.3 20.4 18.5 18.5 18.5 19.2 21.2  
15.4 15.4 11.1 13.5 10.7 17.0 17.1 11.7 15.8 12.7 18.5 18.5 12.2 18.0 14.6  
2.09 2.09 2.09 2.19 2.28 2.24 2.24 2.24 2.30 2.39 2.37 2.39 2.39 2.41 2.49  
75  
85  
T.C.  
S.C.  
KW  
T.C.  
S.C.  
KW  
95  
T.C.  
S.C.  
KW  
105  
115  
125  
T.C.  
S.C.  
KW  
T.C.  
S.C.  
KW  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
Coil  
T.C.  
1.00  
1.00  
1.00  
1.00  
1.02  
1.02  
1.02  
1.02  
1.02  
1.02  
1.02  
1.00  
1.02  
1.03  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
S.C.  
1.00  
1.00  
1.00  
1.00  
1.01  
1.02  
1.01  
1.01  
0.99  
0.99  
0.99  
1.00  
1.02  
1.04  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
KW  
1.00  
1.00  
1.00  
1.00  
1.00  
1.03  
1.00  
1.00  
0.97  
0.97  
0.97  
1.00  
1.02  
1.02  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
MA08B  
MC24B  
PV8*A12  
PV9*A12  
PV8*B16  
P(C,V)9*B12  
PV8*A12  
PV9*A12  
PV8*B16  
P(C,V)9*B12  
PV8*A12  
PV9*A12  
PV8*A12  
PV9*A12  
FC/MC/PC24A  
FC/MC/PC/24A  
FC/MC/PC/24B  
FC/MC/PC24B  
FC/MC/PC30A  
FC/MC/PC30A  
FC/MC/PC30B  
FC/MC/PC30B  
HC30  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.02  
1.02  
1.04  
1.04  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.03  
1.02  
1.04  
1.04  
0.96  
0.97  
0.96  
0.96  
0.96  
0.97  
0.96  
0.96  
0.98  
0.98  
0.99  
0.99  
MA08B  
MC30B  
MA08B  
G*FD024H17  
G*FD030H17  
MA08B  
AHP24  
AHP30  
F*FP024  
F*FP030  
MV12B  
FC/MC24B  
FC/MC30B  
MV12B  
HC30  
AV24  
HD24  
FC/MC/PC/UC30  
HC30  
HD24  
HD24  
G*FA030S14  
G*FA036S14  
G*FA036S17,21  
G*FD024H14,17  
G*FD030H17  
G*FD035H14  
G*FD036H17  
18  
Unitary Products Group  
254892-YTG-C-0606  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H2RD030S06 , H1RD030S(25,46) **  
FC/MC/PC/UC30  
IDCFM  
800  
1000  
75  
1200  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F) 80  
ID WB (°F) 57  
80  
62  
75  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
T.C.  
S.C.  
KW  
27.0 31.8 30.1 33.7 35.6 29.0 33.4 31.3 35.1 36.7 31.1 35.0 32.6 36.5 37.7  
26.9 24.7 20.6 21.2 16.0 29.0 27.7 22.9 23.4 17.7 31.1 30.7 25.2 25.6 19.5  
65  
75  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
1.8  
T.C.  
S.C.  
KW  
25.9 30.3 28.7 32.1 33.6 27.9 31.9 29.9 33.4 34.5 29.8 33.5 31.1 34.7 35.4  
25.9 24.2 20.0 20.5 15.6 27.8 27.0 22.3 22.7 17.2 29.8 29.8 24.5 24.9 18.8  
1.9  
1.9  
1.9  
2.0  
2.0  
1.9  
1.9  
1.9  
2.0  
2.0  
2.0  
1.9  
2.0  
2.0  
2.0  
T.C.  
S.C.  
KW  
24.9 28.8 27.2 30.4 31.7 26.7 30.4 28.4 31.7 32.4 28.6 32.0 29.6 32.9 33.1  
24.9 23.7 19.5 19.7 15.2 26.7 26.3 21.7 21.9 16.7 28.5 28.9 23.9 24.1 18.1  
85  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.2  
2.1  
2.1  
2.1  
2.1  
2.2  
T.C.  
S.C.  
KW  
23.8 27.4 25.8 28.7 29.7 25.6 28.9 26.9 30.0 30.2 27.3 30.5 28.1 31.2 30.7  
23.8 23.2 18.9 18.9 14.8 25.5 25.6 21.1 21.2 16.2 27.3 28.1 23.3 23.4 17.5  
95  
2.2  
2.2  
2.2  
2.3  
2.3  
2.2  
2.2  
2.2  
2.3  
2.3  
2.3  
2.3  
2.2  
2.3  
2.3  
T.C.  
S.C.  
KW  
22.8 25.9 24.3 27.1 27.8 24.4 27.5 25.3 28.2 28.2 26.0 29.1 26.4 29.3 28.5  
22.7 22.4 18.3 18.3 14.1 24.3 24.5 20.4 20.5 15.4 25.9 26.5 22.6 22.6 16.6  
105  
115  
125  
2.4  
2.4  
2.4  
2.4  
2.5  
2.4  
2.4  
2.4  
2.4  
2.5  
2.4  
2.4  
2.4  
2.5  
2.5  
T.C.  
S.C.  
KW  
21.8 24.5 22.8 25.5 25.9 23.2 26.1 23.7 26.5 26.1 24.7 27.8 24.7 27.4 26.4  
21.7 21.6 17.6 17.7 13.5 23.2 23.3 19.7 19.8 14.6 24.7 25.0 21.8 21.9 15.8  
2.5  
2.5  
2.5  
2.6  
2.6  
2.6  
2.5  
2.5  
2.6  
2.7  
2.6  
2.6  
2.5  
2.6  
2.7  
T.C.  
S.C.  
KW  
20.8 23.0 21.3 23.9 24.0 22.1 24.8 22.2 24.7 24.1 23.4 26.5 23.0 25.6 24.3  
20.6 20.9 17.0 17.1 12.8 22.0 22.2 19.0 19.1 13.9 23.4 23.5 21.1 21.1 15.1  
2.7  
2.7  
2.6  
2.7  
2.8  
2.7  
2.7  
2.7  
2.7  
2.8  
2.8  
2.7  
2.7  
2.8  
2.8  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
** For three-phase, decrease T.C. by 0.6 and S.C. by 0.3.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
MA12B  
MA12B  
MA12B  
AHP30  
AHP36  
F*FP036  
MV12B*  
MV12B*  
MV16C*  
AV36*  
Coil  
T.C.  
1.00  
1.00  
1.00  
1.01  
1.01  
1.00  
1.01  
1.01  
1.01  
1.01  
1.00  
1.00  
1.01  
1.01  
1.00  
1.00  
1.00  
S.C.  
1.00  
1.01  
1.01  
1.04  
1.08  
1.01  
1.00  
1.01  
1.01  
1.01  
1.01  
1.03  
1.04  
1.05  
1.00  
1.00  
1.00  
KW  
1.00  
1.00  
1.00  
1.01  
1.01  
1.00  
0.97  
0.97  
0.97  
0.97  
1.00  
1.00  
1.01  
1.01  
1.00  
1.00  
1.00  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
MC30B  
MC36B  
G*FD036H17  
PV8*A12  
FC/MC/PC30A  
FC/MC/PC30A  
FC/MC/PC30B  
FC/MC/PC30B  
FC/MC/PC36A  
FC/MC/PC36A  
FC/MC/PC36B  
FC/MC/PC36B  
FC/MC/PC36C  
FC/MC/PC36C  
FC/MC/PC36C  
FC/MC/PC36C  
HC30  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.00  
1.02  
1.00  
1.00  
1.02  
1.03  
1.03  
1.03  
1.02  
1.02  
1.02  
1.02  
1.03  
1.03  
1.05  
1.05  
1.05  
1.06  
1.06  
1.06  
1.05  
1.06  
1.06  
1.06  
1.01  
0.97  
1.01  
1.01  
1.01  
0.97  
0.97  
0.97  
1.01  
1.01  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
PV9*A12  
PV8*B16  
P(C,V)9*B12  
PV8*A12  
PV9*A12  
FC/MC30B  
FC/MC36B  
FC/MC36C  
PV8*B16  
P(C,V)9*B12  
PV8*C16  
PV8*C20  
FC/MC/PC/UC36  
HC30  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*A12  
HC36  
HD36  
PV9*A12  
HC30  
G*FA036S14  
G*FD036H17  
G*FD036H21  
PV8*B16  
HC36  
P(C,V)9*B12  
PV8*A12  
HC36  
HD36  
*
= Single-phase outdoor units only.  
PV8*B16  
HD36  
PV8*C16  
HD36  
PV8*C20  
HD36  
PV9*A12  
HD36  
P(C,V)9*B12  
P(C,V)9*C16  
P(C,V)9*C20  
HD36  
HD36  
HD36  
*
= Single-phase outdoor units only.  
Unitary Products Group  
19  
254892-YTG-C-0606  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H2RD036S06 , H1RD036S(25,46) **  
FC/MC/PC/UC36  
IDCFM  
1000  
1200  
75  
1400  
75  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F) 80  
ID WB (°F) 57  
80  
62  
75  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
62  
62  
T.C.  
S.C.  
KW  
35.0 35.7 34.7 38.9 40.5 37.2 37.2 35.8 40.0 41.4 39.3 38.8 36.9 41.1 42.3  
32.1 30.0 25.0 25.8 19.7 33.8 32.8 27.5 28.1 21.3 35.6 35.7 29.9 30.4 22.9  
65  
75  
2.0  
2.0  
2.0  
2.0  
2.1  
2.0  
2.0  
2.0  
2.0  
2.1  
2.0  
2.0  
2.0  
2.0  
2.1  
T.C.  
S.C.  
KW  
33.3 34.2 33.1 37.0 38.7 35.6 35.9 34.3 38.1 39.5 38.0 37.6 35.4 39.1 40.4  
30.5 29.0 24.3 24.9 19.2 32.3 31.7 26.7 27.2 20.7 34.2 34.4 29.1 29.5 22.3  
2.2  
2.2  
2.2  
2.2  
2.3  
2.2  
2.2  
2.2  
2.2  
2.3  
2.2  
2.2  
2.2  
2.2  
2.3  
T.C.  
S.C.  
KW  
31.6 32.6 31.6 35.1 36.8 34.1 34.5 32.8 36.1 37.7 36.6 36.3 34.0 37.1 38.5  
28.8 28.0 23.5 24.0 18.6 30.8 30.6 25.9 26.4 20.2 32.9 33.2 28.4 28.7 21.8  
85  
2.3  
2.4  
2.4  
2.4  
2.5  
2.4  
2.4  
2.4  
2.4  
2.5  
2.4  
2.4  
2.4  
2.4  
2.5  
T.C.  
S.C.  
KW  
29.9 31.1 30.0 33.2 35.0 32.5 33.1 31.3 34.8 35.8 35.2 35.1 32.5 35.1 36.6  
27.2 27.0 22.7 23.1 18.0 29.3 29.5 25.2 25.4 19.6 31.5 31.9 27.6 27.9 21.2  
95  
2.5  
2.5  
2.5  
2.6  
2.7  
2.5  
2.6  
2.6  
2.6  
2.7  
2.6  
2.6  
2.6  
2.6  
2.7  
T.C.  
S.C.  
KW  
28.8 29.5 28.1 31.1 32.6 31.0 31.3 29.2 32.0 33.3 33.3 33.2 30.3 33.0 34.0  
26.1 25.9 21.7 22.2 17.3 27.9 28.0 24.0 24.5 18.8 29.7 30.1 26.3 26.9 20.4  
105  
115  
125  
2.7  
2.7  
2.7  
2.8  
2.9  
2.7  
2.8  
2.7  
2.8  
2.9  
2.8  
2.8  
2.8  
2.8  
2.9  
T.C.  
S.C.  
KW  
27.7 27.9 26.3 29.1 30.4 29.6 29.6 27.2 30.0 30.9 31.5 31.3 28.2 30.9 31.4  
25.0 24.9 20.7 21.3 16.6 26.5 26.6 22.9 23.6 18.1 28.0 28.4 25.0 25.9 19.6  
2.9  
2.9  
2.9  
3.0  
3.1  
2.9  
2.9  
2.9  
3.0  
3.1  
3.0  
3.0  
2.9  
3.0  
3.1  
T.C.  
S.C.  
KW  
26.6 26.3 24.4 27.0 28.1 28.2 27.9 25.3 27.9 28.4 29.7 29.5 26.1 28.8 28.8  
24.0 23.8 19.8 20.4 15.9 25.1 25.3 21.7 22.7 17.3 26.2 26.7 23.7 25.0 18.8  
3.1  
3.1  
3.0  
3.1  
3.3  
3.1  
3.1  
3.1  
3.2  
3.3  
3.2  
3.2  
3.1  
3.2  
3.3  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
** For three-phase, decrease T.C. by 0.3 and S.C. by 0.2.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
Coil  
T.C.  
1.00  
1.00  
1.01  
1.01  
1.03  
1.00  
1.01  
1.01  
1.01  
1.03  
1.01  
1.03  
1.00  
1.00  
1.00  
1.00  
1.03  
1.00  
S.C.  
1.00  
1.00  
1.07  
1.08  
1.05  
1.00  
0.98  
0.99  
0.99  
0.99  
1.01  
1.05  
1.00  
1.00  
1.00  
1.00  
1.05  
1.00  
KW  
1.00  
1.00  
1.01  
1.01  
0.99  
1.00  
1.01  
0.97  
0.97  
1.00  
1.01  
1.03  
1.00  
1.00  
1.00  
1.00  
1.03  
1.00  
Variable Speed  
Furnace *  
Coil  
T.C.  
S.C.  
KW  
MA12B  
FC/MC36B  
PV8*A12  
FC/MC/PC36A  
FC/MC/PC36A  
FC/MC/PC36B  
FC/MC/PC36B  
FC/MC/PC36C  
FC/MC/PC36C  
FC/MC/PC36C  
FC/MC/PC36C  
HC36  
1.01  
1.00  
1.01  
1.01  
1.01  
1.01  
1.01  
1.01  
1.03  
1.03  
1.03  
1.03  
1.03  
1.03  
1.03  
1.03  
1.03  
1.03  
1.00  
1.00  
1.01  
1.00  
1.01  
1.01  
1.01  
1.01  
1.05  
1.04  
1.05  
1.06  
1.06  
1.06  
1.05  
1.05  
1.06  
1.06  
1.01  
1.00  
1.01  
1.01  
0.97  
0.97  
1.01  
0.97  
0.99  
1.03  
1.03  
0.99  
0.99  
0.99  
1.03  
0.99  
0.99  
0.99  
MA12B  
G*FD036H17  
PV9*A12  
AHP36  
PV8*B16  
AHP42  
P(C,V)9*B12  
PV8*C16  
AHP/SHP60  
F*FP040  
PV8*C20  
MV12B*  
FC/MC36B  
FC/MC36C  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*B16  
MV16C*  
AV36*  
AV/SV48*  
P(C,V)9*B12  
PV8*A12  
HC36  
HC36  
HD36  
HD36  
PV8*B16  
HD36  
G*FA048S17  
G*FA048S21  
G*FD036H17  
G*FD036H21  
G*FD042H21  
G*FD046H17  
PV8*C16  
HD36  
PV8*C20  
HD36  
PV9*A12  
HD36  
P(C,V)9*B12  
P(C,V)9*C16  
P(C,V)9*C20  
HD36  
HD36  
HD36  
*
= Single-phase outdoor units only.  
*
= Single-phase outdoor units only.  
20  
Unitary Products Group  
254892-YTG-C-0606  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H2RD042S06 , H1RD042S(25,46) **  
FC/MC/PC/UC42  
IDCFM  
1200  
1400  
75  
1600  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F) 80  
ID WB (°F) 57  
80  
62  
75  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
T.C.  
S.C.  
KW  
39.6 44.0 42.6 46.7 50.0 41.5 45.0 43.4 47.6 50.4 43.4 46.0 44.3 48.5 50.8  
39.3 37.3 30.7 31.1 23.6 41.0 39.7 33.1 33.3 24.7 42.7 42.2 35.5 35.5 25.7  
65  
75  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
2.3  
T.C.  
S.C.  
KW  
38.0 41.8 40.3 44.4 47.2 40.0 42.9 41.1 45.2 47.7 41.9 43.9 41.9 46.0 48.1  
37.6 36.1 29.8 30.0 22.7 39.3 38.5 32.0 32.2 23.8 40.9 40.8 34.2 34.4 24.8  
2.5  
2.5  
2.5  
2.5  
2.6  
2.5  
2.5  
2.5  
2.5  
2.6  
2.5  
2.5  
2.5  
2.5  
2.6  
T.C.  
S.C.  
KW  
36.4 39.6 38.0 42.1 44.4 38.4 40.7 38.7 42.8 44.9 40.4 41.9 39.4 43.4 45.4  
36.0 34.9 28.8 28.9 21.8 37.6 37.2 30.9 31.1 22.9 39.2 39.5 33.0 33.4 24.0  
85  
2.7  
2.7  
2.7  
2.7  
2.8  
2.7  
2.7  
2.7  
2.7  
2.8  
2.7  
2.7  
2.7  
2.8  
2.8  
T.C.  
S.C.  
KW  
34.7 37.4 35.7 39.8 41.6 36.9 38.6 36.3 40.5 42.2 39.0 39.8 36.9 40.9 42.8  
34.3 33.8 27.8 27.8 20.8 35.9 36.0 29.8 29.6 22.0 37.4 38.2 31.7 32.3 23.1  
95  
2.9  
2.9  
2.9  
3.0  
3.1  
2.9  
2.9  
2.9  
3.0  
3.1  
2.9  
2.9  
2.9  
3.0  
3.1  
T.C.  
S.C.  
KW  
33.3 35.6 33.5 37.4 39.0 35.2 36.7 34.1 37.9 39.4 37.2 37.7 34.7 38.4 39.8  
32.1 32.6 26.9 26.9 19.8 33.8 34.5 28.8 29.0 21.0 35.6 36.3 30.8 31.2 22.2  
105  
115  
125  
3.1  
3.1  
3.1  
3.2  
3.3  
3.1  
3.1  
3.1  
3.2  
3.3  
3.2  
3.2  
3.1  
3.2  
3.3  
T.C.  
S.C.  
KW  
31.9 33.8 31.4 35.1 36.4 33.6 34.7 31.9 35.6 36.6 35.4 35.7 32.5 36.0 36.8  
31.4 31.5 26.0 26.0 18.9 32.6 33.0 27.9 28.0 20.1 33.8 34.5 29.8 30.1 21.3  
3.3  
3.3  
3.3  
3.4  
3.5  
3.4  
3.4  
3.3  
3.4  
3.5  
3.4  
3.4  
3.4  
3.4  
3.6  
T.C.  
S.C.  
KW  
30.5 32.0 29.2 32.8 33.9 32.1 32.8 29.8 33.2 33.9 33.6 33.7 30.3 33.6 33.9  
30.0 30.4 25.2 25.1 17.9 31.0 31.5 27.0 27.0 19.1 32.1 32.6 28.8 28.9 20.4  
3.5  
3.5  
3.5  
3.6  
3.8  
3.6  
3.6  
3.5  
3.6  
3.8  
3.6  
3.6  
3.6  
3.7  
3.8  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
** For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
MA12C  
MA14D  
MA12C  
MA14D  
MA12C  
MA12C  
AHP42  
AHP/SHP48  
AHP/SHP60  
F*FP048  
MV16C*  
MV16C*  
MV20D*  
AV/SV48*  
Coil  
T.C.  
1.00  
1.00  
1.01  
1.01  
1.00  
1.01  
1.01  
1.04  
1.00  
1.01  
1.00  
1.02  
1.02  
1.00  
1.01  
1.01  
1.02  
1.00  
1.01  
1.00  
1.00  
1.01  
S.C.  
1.00  
1.00  
1.02  
1.02  
1.00  
1.02  
1.05  
1.04  
1.12  
1.05  
0.98  
1.00  
1.01  
0.98  
1.02  
1.01  
1.00  
1.00  
1.02  
1.00  
1.00  
1.02  
KW  
1.00  
1.00  
1.01  
1.01  
1.00  
1.01  
1.01  
1.04  
0.96  
1.01  
1.00  
0.98  
0.98  
1.00  
1.01  
1.01  
1.02  
1.00  
1.01  
1.00  
1.00  
1.01  
Variable Speed  
Furnace  
Coil  
T.C.  
S.C.  
KW  
MC42C  
PV8*B16  
FC/MC/PC42B  
FC/MC/PC42C  
FC/MC/PC42C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48D  
HC48  
1.00  
1.00  
1.00  
1.02  
1.02  
1.02  
1.02  
1.02  
1.01  
1.02  
1.01  
1.01  
1.04  
1.04  
1.04  
1.04  
1.04  
1.00  
1.00  
1.00  
1.02  
1.02  
1.02  
1.02  
1.02  
1.01  
1.02  
1.01  
1.02  
1.03  
1.03  
1.03  
1.03  
1.03  
1.00  
1.00  
1.00  
1.02  
0.98  
1.02  
1.02  
1.02  
1.01  
1.02  
1.01  
1.01  
0.99  
0.99  
1.04  
0.99  
0.99  
MC42D  
PV8*C16  
MC48C  
PV8*C20  
MC48D  
PV8*C16  
G*FD042H21  
G*FD048H21  
PV8*C20  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C16  
PV8*C20  
HC48  
FC/MC42C  
FC/MC48C  
FC/MC48D  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*C16  
HC48  
HC48  
HD48  
PV8*C20  
HD48  
FC/MC/PC/UC48  
HC48  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
HD48  
HD48  
HD48  
HD48  
G*FA048S17  
G*FA048S21  
G*FD042H21  
G*FD046H17  
G*FD048H21,24  
*
= Single-phase outdoor units only.  
*
= Single-phase outdoor units only.  
Unitary Products Group  
21  
254892-YTG-C-0606  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H2RD048S06, H1RD048S(25,46) **  
FC/MC/PC/UC48  
IDCFM  
1400  
1600  
75  
1800  
75  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F) 80  
ID WB (°F) 57  
80  
62  
75  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
62  
62  
T.C.  
S.C.  
KW  
45.9 49.0 47.2 51.9 54.5 48.7 50.8 48.2 52.9 54.7 51.5 52.5 49.2 53.9 54.9  
44.2 41.8 34.6 34.7 27.5 45.8 44.4 36.9 36.9 28.2 47.5 47.0 39.2 39.0 29.0  
65  
75  
2.6  
2.6  
2.6  
2.7  
2.7  
2.6  
2.6  
2.6  
2.7  
2.7  
2.6  
2.6  
2.6  
2.7  
2.7  
T.C.  
S.C.  
KW  
44.6 47.5 45.7 50.3 52.8 47.4 48.9 46.5 51.0 53.0 50.1 50.4 47.4 51.7 53.2  
42.9 41.2 34.0 34.2 26.9 44.5 43.7 36.2 36.3 28.0 46.1 46.1 38.5 38.4 29.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
T.C.  
S.C.  
KW  
43.3 45.9 44.1 48.7 51.1 46.0 47.1 44.9 49.1 51.3 48.8 48.2 45.6 49.6 51.6  
41.6 40.6 33.4 33.7 26.4 43.1 42.9 35.6 35.7 27.7 44.6 45.2 37.7 37.8 28.9  
85  
3.3  
3.3  
3.3  
3.4  
3.4  
3.3  
3.3  
3.3  
3.4  
3.4  
3.3  
3.3  
3.3  
3.4  
3.4  
T.C.  
S.C.  
KW  
42.0 44.4 42.6 47.1 49.3 44.7 45.2 43.2 47.0 49.7 47.4 46.1 43.8 47.5 50.0  
40.4 39.9 32.8 33.1 25.9 41.8 42.1 34.9 35.1 27.4 43.1 44.3 37.0 37.2 28.9  
95  
3.7  
3.7  
3.6  
3.7  
3.7  
3.7  
3.7  
3.7  
3.7  
3.7  
3.7  
3.7  
3.7  
3.7  
3.7  
T.C.  
S.C.  
KW  
40.5 42.5 40.5 44.7 46.4 43.1 43.5 41.1 44.8 46.7 45.6 44.4 41.7 45.0 47.0  
38.7 38.5 31.8 32.2 24.9 40.0 40.4 33.9 34.2 26.4 41.4 42.3 36.0 36.3 27.8  
105  
115  
125  
4.2  
4.2  
4.1  
4.2  
4.2  
4.2  
4.2  
4.2  
4.2  
4.2  
4.2  
4.2  
4.2  
4.2  
4.2  
T.C.  
S.C.  
KW  
39.1 40.7 38.4 42.3 43.5 41.5 41.7 39.0 42.5 43.8 43.9 42.8 39.7 42.6 44.1  
37.2 37.2 30.8 31.2 24.0 38.4 38.7 32.9 33.3 25.4 39.6 40.3 35.0 35.4 26.8  
4.7  
4.6  
4.6  
4.7  
4.7  
4.7  
4.7  
4.6  
4.7  
4.7  
4.7  
4.7  
4.6  
4.7  
4.7  
T.C.  
S.C.  
KW  
37.7 38.8 36.3 40.0 40.7 39.9 40.0 37.0 40.1 40.9 42.1 41.2 37.6 40.3 41.2  
35.6 35.8 29.9 30.3 23.1 36.7 37.0 32.0 32.4 24.4 37.9 38.3 34.0 34.5 25.8  
5.2  
5.1  
5.1  
5.2  
5.2  
5.2  
5.1  
5.1  
5.2  
5.2  
5.2  
5.2  
5.1  
5.2  
5.2  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
** For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
MA12C  
MA20D  
MA12C  
MA20D  
AHP/SHP48  
F*FV060*  
AHP/SHP60  
MV16C*  
MV20D*  
AV/SV48*  
Coil  
T.C.  
1.01  
1.00  
1.01  
1.00  
1.00  
1.01  
1.01  
1.00  
1.00  
1.00  
0.99  
1.00  
1.00  
S.C.  
1.02  
1.00  
1.02  
1.00  
1.05  
1.05  
1.03  
0.99  
0.99  
0.99  
1.00  
0.99  
1.00  
KW  
1.01  
1.00  
1.01  
1.00  
1.00  
1.01  
1.01  
1.00  
1.00  
1.00  
0.99  
1.00  
1.00  
Variable Speed  
Furnace *  
Coil  
T.C.  
S.C.  
KW  
MC48C  
PV8*C16  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48C  
FC/MC/PC48D  
HC48  
0.99  
1.00  
1.00  
1.00  
1.00  
0.99  
1.00  
0.99  
0.99  
1.01  
1.01  
1.01  
1.01  
1.01  
0.97  
1.00  
1.00  
1.00  
1.00  
0.97  
1.00  
1.00  
1.00  
0.99  
1.02  
1.02  
1.02  
1.02  
0.99  
1.00  
1.00  
1.00  
1.00  
0.99  
1.00  
0.99  
0.99  
1.01  
1.01  
1.01  
1.01  
1.01  
MC48D  
PV8*C20  
G*FD048H21  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C16  
G*FD048H24  
PV8*C20  
HC48  
FC/MC48C  
FC/MC48D  
P(C,V)9*C16  
P(C,V)9*C20  
PV8*C16  
HC48  
HC48  
HD48  
HC48  
PV8*C20  
HD48  
HD48  
P(C,V)9*C16  
P(C,V)9*C20  
P(C,V)9*D20  
HD48  
G*FD048H21,24  
HD48  
*
= Single-phase outdoor units only.  
HD48  
*
= Single-phase outdoor units only.  
22  
Unitary Products Group  
254892-YTG-C-0606  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H2RD060S06, H1RD060S(25,46)**  
FC/MC/PC/UC60  
IDCFM  
1650  
1900  
75  
2150  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F) 80  
ID WB (°F) 57  
80  
62  
75  
62  
80  
67  
80  
72  
80  
57  
80  
62  
80  
67  
80  
72  
80  
57  
80  
62  
75  
62  
80  
67  
80  
72  
62  
T.C.  
S.C.  
KW  
57.2 57.4 54.0 59.6 59.1 58.9 59.1 55.2 60.4 61.1 60.6 60.8 56.3 61.2 63.1  
52.1 48.7 39.6 38.8 28.1 54.1 51.9 42.7 42.0 31.1 56.1 55.2 45.7 45.3 34.1  
65  
75  
3.0  
3.1  
3.1  
3.1  
3.1  
3.0  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
T.C.  
S.C.  
KW  
54.9 55.1 51.6 57.2 57.0 56.9 56.8 52.7 58.1 58.2 59.0 58.5 53.8 59.0 59.5  
50.0 47.4 38.6 38.0 27.7 52.1 50.5 41.6 41.1 30.0 54.2 53.6 44.7 44.2 32.3  
3.5  
3.5  
3.5  
3.6  
3.6  
3.5  
3.5  
3.5  
3.6  
3.6  
3.5  
3.5  
3.5  
3.6  
3.6  
T.C.  
S.C.  
KW  
52.6 52.9 49.3 54.8 54.8 54.9 54.5 50.3 55.8 55.4 57.3 56.1 51.2 56.9 55.9  
48.0 46.1 37.6 37.3 27.3 50.1 49.0 40.6 40.2 28.8 52.3 52.0 43.6 43.2 30.4  
85  
4.0  
4.0  
4.0  
4.0  
4.1  
4.0  
4.0  
4.0  
4.0  
4.1  
4.0  
4.0  
4.0  
4.0  
4.1  
T.C.  
S.C.  
KW  
50.2 50.7 46.9 52.4 52.7 52.9 52.2 47.8 55.0 52.5 55.6 53.7 48.7 54.7 52.3  
45.9 44.8 36.5 36.5 26.9 48.1 47.6 39.5 39.6 27.7 50.4 50.4 42.5 42.1 28.5  
95  
4.4  
4.4  
4.4  
4.4  
4.6  
4.5  
4.4  
4.4  
4.5  
4.6  
4.5  
4.4  
4.4  
4.5  
4.6  
T.C.  
S.C.  
KW  
48.3 48.2 44.9 49.9 49.4 50.5 49.9 45.3 50.8 49.2 52.8 51.6 45.6 51.6 49.0  
43.9 43.2 35.6 35.4 25.7 46.0 45.6 38.4 38.1 26.8 48.0 47.9 41.1 40.8 28.0  
105  
115  
125  
5.1  
5.0  
5.1  
5.1  
5.2  
5.1  
5.1  
5.1  
5.1  
5.2  
5.1  
5.1  
5.1  
5.1  
5.2  
T.C.  
S.C.  
KW  
46.4 45.9 43.0 47.5 46.1 48.2 47.7 42.8 48.1 46.0 50.0 49.6 42.5 48.6 45.9  
42.0 41.7 34.7 34.4 24.6 43.9 43.6 37.2 37.0 26.0 45.7 45.5 39.8 39.5 27.5  
5.7  
5.7  
5.7  
5.7  
5.8  
5.7  
5.7  
5.7  
5.7  
5.8  
5.7  
5.7  
5.7  
5.7  
5.8  
T.C.  
S.C.  
KW  
44.5 43.5 41.1 45.1 42.9 45.8 45.5 40.3 45.3 42.8 47.2 47.6 39.5 45.6 42.7  
40.1 40.2 33.7 33.4 23.5 41.8 41.6 36.1 35.8 25.2 43.4 43.1 38.4 38.3 26.9  
6.3  
6.3  
6.3  
6.3  
6.4  
6.3  
6.3  
6.3  
6.3  
6.5  
6.3  
6.4  
6.3  
6.3  
6.5  
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.  
** For three-phase, decrease T.C. by 0.5 and S.C. by 0.3.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Air Handler  
MA20D  
MA20D  
MA20D  
MA20D  
AHP/SHP60  
F*FV060*  
MV20D*  
MV20D*  
AV/SV60*  
Coil  
T.C.  
1.00  
1.01  
1.00  
1.01  
1.00  
1.00  
0.98  
1.01  
1.00  
1.01  
1.00  
1.00  
1.00  
1.00  
1.01  
1.00  
S.C.  
1.00  
1.01  
1.00  
1.01  
1.02  
1.02  
0.97  
0.99  
1.02  
1.01  
1.00  
1.01  
1.00  
1.00  
1.01  
1.00  
KW  
1.00  
1.01  
1.00  
1.01  
1.00  
1.00  
0.98  
1.01  
1.00  
1.01  
1.00  
1.00  
1.00  
1.00  
1.01  
1.00  
Variable Speed  
Furnace*  
Coil  
T.C.  
S.C.  
KW  
MC60D  
MC61D  
G*FD060H24  
G*FD061H24  
P(C,V)9*D20  
PV8*C20  
FC/MC/PC60D  
FC/PC60C  
FC/PC60C  
HC60  
0.99  
0.98  
0.99  
0.98  
0.99  
1.00  
0.99  
0.98  
1.00  
0.98  
1.00  
0.96  
0.98  
0.96  
0.98  
0.96  
0.99  
0.96  
0.96  
0.99  
0.96  
0.96  
0.99  
0.98  
0.99  
0.98  
0.99  
1.00  
0.99  
0.98  
1.00  
0.98  
1.00  
P(C,V)9*C20  
PV8*C20  
P(C,V)9*D20  
PV8*C20  
HC60  
HD60  
FC/MC60D  
MC61D  
P(C,V)9*C20  
P(C,V)9*D20  
PV8*C20  
HD60  
HD60  
MC61D  
MC61D  
MC61D  
MC61  
P(C,V)9*C20  
P(C,V)9*D20  
HC60  
HD60  
G*FA060S21,24  
G*FD060H24  
G*FD061H24  
MC60D  
*
= Single-phase outdoor units only.  
MA20D  
*
= Single-phase outdoor units only.  
Unitary Products Group  
23  
NOTES  
Subject to change without notice. Printed in U.S.A.  
Copyright © by York International Corp. 2006. All rights reserved.  
254892-YTG-C-0606  
Supersedes: 254892 / 036-21339-002 Rev. B (0206)  
Unitary  
Products  
Group  
5005  
York  
Drive  
Norman  
OK  
73069  

Subaru Robin Power Products Automobile Parts Eh12 2d User Manual
Schumacher Ps 2352 User Manual
Sanyo 36kh72r User Manual
Saft Batteries Automobile Parts Lst User Manual
Mitsubishi Electronics Mitsubishi Digital Electronics Air Conditioner Msz Fdna User Manual
Lexmark 4564 User Manual
JVC DR MV1 User Manual
GE APWA14 User Manual
Cub Cadet 221 Lhp Engine User Manual
ASUS VG27V 02 User Manual