Samsung Officeserv 7100 User Manual

Ed. 00  
OfficeServ 7100  
Installation Manual  
OfficeServ 7100 Installation Manual  
INTRODUCTION  
Purpose  
OfficeServ 7100 is the most suitable system for offices using circuit lines with 10 to 25  
subscribers. This manual describes the condition for OfficeServ 7100 system installation  
and how to install, inspect and operate the system.  
Document Content and Organization  
This document consists of eight chapters, and abbreviations as follows:  
CHAPTER 1. Before Installing  
This chapter describes the checklists, such as the installation site and the grounding & the  
power conditions, to be inspected before installing the OfficeServ 7100 system.  
This chapter also describes the items included in the OfficeServ 7100 package and the  
installation procedure.  
CHAPTER 2. Installing Cabinets  
This chapter describes how to install an OfficeServ 7100 cabinet on the ground or inside a  
rack, depending on the installation environment, and how to connect the grounding wire.  
CHAPTER 3. Mounting and Replacing Boards  
This chapter describes how to mount or replace various boards of the OfficeServ 7100  
system.  
CHAPTER 4. Connecting External Batteries  
This chapter describes how to connect an external battery to the OfficeServ 7100 system.  
CHAPTER 5. Connecting the Power  
This chapter describes how to connect the power to the OfficeServ 7100 system.  
CHAPTER 6. Connecting C.O. Lines  
This chapter describes how to connect C.O. lines to the OfficeServ 7100 system.  
© SAMSUNG Electronics Co., Ltd.  
I
Ошибка! Стиль не определен.  
CHAPTER 7. Connecting Stations and Additional Equipment  
This chapter describes how to connect various stations and additional equipment, such as  
analog/digital phones, door phones and door locks, to the OfficeServ 7100 system.  
CHAPTER 8. Starting the System  
This chapter describes items to check before starting the OfficeServ 7100 system, the procedure  
for starting the system, and the procedure for testing whether the system is normally operating  
after startup.  
ABBREVIATION  
Abbreviations frequently used in this document are described.  
Conventions  
The following types of paragraphs contain special information that must be carefully read  
and thoroughly understood. Such information may or may not be enclosed in a rectangular  
box, separating it from the main text, but is always preceded by an icon and/or a bold title.  
WARNING  
Provides information or instructions that the reader should follow in order to avoid  
personal injury or fatality.  
CAUTION  
Provides information or instructions that the reader should follow in order to avoid  
a service failure or damage to the system.  
CHECKPOINT  
Provides the operator with checkpoints for stable system operation.  
NOTE  
Indicates additional information as a reference.  
II  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
Reference  
OfficeServ 7100 System Manual  
This document introduces OfficeServ 7100 and describes the system information, such as  
hard configuration, specification, and functions, necessary for this system.  
OfficeServ 7100 Programming Manual  
This document describes how to use the MMC program to change the OfficeServ 7100  
system setting by using a phone.  
Revision History  
EDITION  
DATE OF ISSUE  
REMARKS  
00  
01  
02  
08. 2006.  
01.2007.  
04.2007.  
Original Draft  
Safety, VM and Router etc.  
DoC, 2BRM Modular Jack Connection  
© SAMSUNG Electronics Co., Ltd.  
III  
Ошибка! Стиль не определен.  
This page is intentionally left blank.  
IV  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
SAFETY CONCERNS  
For product safety and correct operation, the following information must be given to the  
operator/user and shall be read before the installation and operation.  
Symbols  
Caution  
Indication of a general caution  
Restriction  
Indication for prohibiting an action for a product  
Instruction  
Indication for commanding a specifically required action  
© SAMSUNG Electronics Co., Ltd.  
V
Ошибка! Стиль не определен.  
Warning  
WARNING  
Caution for Grounding  
- Do not connect the grounding wire of the OfficeServ 7100 system to a power  
conduit of a building  
- The standards for power and grounding should comply with the country standard  
and the pertinent work should be conducted according to the country standard.  
- External grounding is required to prevent human injuries or system damages  
caused by lightning, static electricity, or voltage surge.  
- Unplug the AC power cord before connecting the grounding wire. Failure to do  
so may cause human injury.  
- The OfficeServ 7100 system should be connected to an outlet with a protective  
ground.  
- The GND in the back panel of the OfficeServ 7100 system should be grounded.  
Use of Double-pole/neutral fusing  
If the system is repaired after removing only one fuse used in the neutral line,  
it may cause electric shock. If the repair is required, repair the system after  
extracting the plug of the power cord.  
Caution for powers when mounting boards  
Check if the cabinet power is off when mounting boards on slots. Inserting or  
ejecting a board while the power is on may damage the board.  
Caution for the connection of the ground cable  
Unplug the AC power cord before connecting the ground cable. If the connection  
work is performed when the power cable is connected, it may cause serious  
bodily damage.  
VI  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
Caution  
CAUTION  
Caution for Installation  
Only a trained service staff can install the OfficeServ 7100 system.  
The equipment intended only for installation in a RESTRICTED ACCESS  
LOCATION  
Caution for the connection of External Batteries  
Do not connect an external AC power until the battery and the system is  
completely disconnected. To do so may cause electric shock to the constructor or  
the system.  
Make sure that the specified polarities(+, -) are correctly connected when  
connecting external batteries.  
To reduce risk of fire and injury to persons, use only a sealed nickel cadmium or  
lead-acid battery supply capable of handling a charge current of 0.25 A, a charge  
voltage of -54 V dc and a discharge rate of 26 Ah.  
Leakage currents due to ringing voltage – Earthing installation instructions  
1. A supplementary equipment earthing conductor is to be installed between the  
product or system and earth, that is, in addition to the equipment earthing conductor  
in the power supply cord.  
2. The supplementary equipment earthing conductor may not be smaller in size than  
the unearthed branch-circuit supply conductors. The supplementary equipment  
earthing conductor is to be connected to the product at the terminal provided, and  
connected to earth in a manner that will retain the earth connection when the power  
supply cord is unplugged. The connection to earth of the supplementary earthing  
conductor shall be in compliance with the appropriate rules for terminating bonding  
jumpers in Part K of Article 250 of the National Electrical Code, ANSI/NFPA 70 and  
Article 10 of Part 1 of the Canadian Electrical Code, Part 1, C22.1. Termination of  
the  
supplementary earthing conductor is permitted to be made to building steel, to a  
metal electrical raceway system, or to any earthed item that is permanently and  
reliably connected to the electrical service equipment earthed.  
3. Bare, covered, or insulated earthing conductors are acceptable. A covered or  
insulated conductor must have a continuous outer finish that is either green, or  
green with one or more yellow stripes.  
© SAMSUNG Electronics Co., Ltd.  
VII  
Ошибка! Стиль не определен.  
Separation of TNV and SELV - Pluggable A  
The separate protective earthing terminal provided on this product shall be  
permanently connected to earth. (Instruction)  
Telephone line cord  
To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG) UL Listed  
or CSA Certified Telecommunication Line Cord.  
Safety Instructions for Rack Mount  
The following or similar rack-mount instructions are included with the installation  
instructions:  
- Elevated Operating Ambient If installed in a closed or multi-unit rack assembly,  
the operating ambient temperature of the rack environment may be greater than  
room ambient. Therefore, consideration should be given to installing the  
equipment in an environment compatible with the maximum ambient temperature  
(Tma) specified by the manufacturer.  
- Reduced Air Flow: Installation of the equipment in a rack should be such that the  
amount of air flow required for safe operation of the equipment is not  
compromised.  
- Mechanical Loading: Mounting of the equipment in the rack should be such that  
a hazardous condition is not achieved due to uneven mechanical loading.  
- Circuit Overloading: Consideration should be given to the connection of the  
equipment to the supply circuit and the effect that overloading of the circuits might  
have on over-current protection and supply wiring. Appropriate consideration of  
equipment nameplate ratings should be used when addressing this concern.  
- Reliable Earthing: Reliable earthing of rack-mounted equipment should be  
maintained. Particular attention should be given to supply connections other than  
direct connections to the branch circuit (e.g. use of power strips)."  
Prohibition of Metal Accessories  
Do not wear metal accessories such as rings and watches to prevent electric  
damages to the system.  
VIII  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
Un-allowed Use of Selector Switch  
The OfficeServ 7100 system only use 230 V. Do not change the input power  
freely by means of the selector switch.  
AC Power Connection Inhibited  
Do not operate other devices with the AC power of the OfficeServ 7100 system or  
with the DC power of external batteries.  
Check of Power-off  
Check if the cabinet power is off when mounting boards on slots. Inserting or  
ejecting a board while the power is on may damage the board.  
Board Reset  
New settings are applied only after the board is reset. The system may  
malfunction if the board is not properly initialized.  
Caution for Installation  
Only a trained service staff can install the OfficeServ 7100 system.  
© SAMSUNG Electronics Co., Ltd.  
IX  
Ошибка! Стиль не определен.  
This page is intentionally left blank.  
X
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
TABLE OF CONTENTS  
INTRODUCTION  
I
Purpose ................................................................................................................................................. I  
Document Content and Organization..................................................................................................... I  
Conventions........................................................................................................................................... II  
Reference............................................................................................................................................. III  
Revision History.................................................................................................................................... III  
SAFETY CONCERNS  
IV  
Symbols................................................................................................................................................IV  
Warning.................................................................................................................................................IV  
Caution .................................................................................................................................................IV  
CHAPTER 1. Before Installing  
1-4  
1.1  
Site Information ..................................................................................................................... 1-4  
1.1.1 Safety Conditions..................................................................................................................1-4  
1.1.2 Temperature and Humidity....................................................................................................1-4  
1.2  
1.3  
1.4  
Grounding Conditions .......................................................................................................... 1-4  
Power Conditions.................................................................................................................. 1-4  
Checking the Package .......................................................................................................... 1-4  
CHAPTER 2. Installing Cabinets  
2-4  
2.1  
2.2  
2.3  
Procedure for the System Installation ................................................................................. 2-4  
Selecting Installation Method............................................................................................... 2-4  
Installing in a Rack ................................................................................................................ 2-4  
2.3.1 Cautions for Installation.........................................................................................................2-4  
2.3.2 Tools Required ......................................................................................................................2-4  
2.3.3 Installing in a Rack ................................................................................................................2-4  
2.4  
Installing on a Wall ................................................................................................................ 2-4  
2.4.1 Tools Required ......................................................................................................................2-4  
2.4.2 Installing on a Wall ................................................................................................................2-4  
© SAMSUNG Electronics Co., Ltd.  
XI  
Ошибка! Стиль не определен.  
2.5  
Connecting the Grounding Wire...........................................................................................2-4  
CHAPTER 3. Mounting and Replacing Boards  
3-4  
3.1  
3.2  
Cabinet Configuration ...........................................................................................................3-4  
Mounting Control Boards......................................................................................................3-4  
3.2.1 Setting Switches and Mounting Option Boards....................................................................3-4  
3.2.2 Mounting Control Boards ......................................................................................................3-4  
3.3  
Mounting Interface Boards....................................................................................................3-4  
3.3.1 Setting Switches and Mounting Optional Boards .................................................................3-4  
3.3.2 Mounting Interface Boards to Slots.......................................................................................3-4  
3.4  
3.5  
Connecting Power Fail Transfer ...........................................................................................3-4  
Replacing Boards...................................................................................................................3-4  
CHAPTER 4. Connecting External Batteries  
4-4  
4.1  
4.2  
Cautions for Connecting External Batteries........................................................................4-4  
Connecting External Batteries..............................................................................................4-4  
CHAPTER 5. Connecting the Power  
5-4  
5.1  
5.2  
Cautions when Connecting Power .......................................................................................5-4  
Connecting the Power ...........................................................................................................5-4  
CHAPTER 6. Connecting C.O. Line  
6-4  
6.1  
6.2  
Line Conditions......................................................................................................................6-4  
Connecting the C.O. Line ......................................................................................................6-4  
6.2.1 Cautions to Connect the C.O. Line.......................................................................................6-4  
6.2.2 Connecting Common C.O. Line............................................................................................6-4  
6.2.3 Connecting T1/E1/PRI ..........................................................................................................6-4  
CHAPTER 7. Connecting Stations and Additional Equipment  
7-4  
7.1  
Connecting Stations ..............................................................................................................7-4  
7.1.1 Cautions for Connecting Stations..........................................................................................7-4  
7.1.2 Connecting Analog Phones...................................................................................................7-4  
7.1.3 Connecting Digital Phones....................................................................................................7-4  
7.1.4 Connecting IP Phones ..........................................................................................................7-4  
7.1.5 Connecting to a Door Phone and a Door Lock.....................................................................7-4  
XII  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
7.2  
Connecting Additional Equipment....................................................................................... 7-4  
7.2.1 Connecting MOH/BGM Equipment ......................................................................................7-4  
7.2.2 Connecting External/Additional Page Equipment.................................................................7-4  
7.2.3 Connecting Common Bell.....................................................................................................7-4  
7.2.4 Changing System Setting .....................................................................................................7-4  
7.2.5 Connecting SMDR ................................................................................................................7-4  
7.2.6 Connecting Printers...............................................................................................................7-4  
CHAPTER 8. Starting the System  
8-4  
8.1  
Pre-Check............................................................................................................................... 8-4  
8.1.1 Environment..........................................................................................................................8-4  
8.1.2 Safety Conditions..................................................................................................................8-4  
8.2  
8.3  
8.4  
Starting the System............................................................................................................... 8-4  
Numbering Extensions and C.O. Lines ............................................................................... 8-4  
Checking System Operation................................................................................................. 8-4  
8.4.1 Station Call Function .............................................................................................................8-4  
8.4.2 Station Camp-On Function....................................................................................................8-4  
8.4.3 C.O. Line Call Function.........................................................................................................8-4  
8.4.4 C.O. Line Camp-On Function ...............................................................................................8-4  
ABBREVIATION  
IV  
4 ~ I.......................................................................................................................................................IV  
K ~ W....................................................................................................................................................IV  
© SAMSUNG Electronics Co., Ltd.  
XIII  
Ошибка! Стиль не определен.  
LIST OF FIGURES  
Figure 2.1 Tools for the Installation inside a Rack...................................................................2-4  
Figure 2.2 Rack Installation (1) ...............................................................................................2-4  
Figure 2.3 Rack Installation (2) ...............................................................................................2-4  
Figure 2.4 Rack Installation (3) ...............................................................................................2-4  
Figure 2.5 Required Tools for the installation on a Wall ..........................................................2-4  
Figure 2.6 Installation on a Wall (1).........................................................................................2-4  
Figure 2.7 Installation on a Wall (2).........................................................................................2-4  
Figure 2.8 Installation on a Wall (3).........................................................................................2-4  
Figure 2.9 Installation on a Wall (4).........................................................................................2-4  
Figure 2.10 Installation on a Wall (5).......................................................................................2-4  
Figure 2.11 Installation on a Wall (6).......................................................................................2-4  
Figure 2.12 Installation on a Wall (7)......................................................................................2-4  
Figure 2.13 Grounding............................................................................................................2-4  
Figure 3.1 Front/rear View of OfficeServ 7100 Cabinet...........................................................3-4  
Figure 3.2 Setting Switches of MP10/11 Board.......................................................................3-4  
Figure 3.3 Mounting a Modem Board on the MP10/11 Board .................................................3-4  
Figure 3.4 Mounting 4SWM/4DLM on the MP10/11 Board .....................................................3-4  
Figure 3.5 Mounting the Control Board to Slot 0.....................................................................3-4  
Figure 3.6 Inserting the Control Board to a connector of the Main Board ...............................3-4  
Figure 3.7 Mounting the UNI Board ........................................................................................3-4  
Figure 3.8 Setting the Switch of the TEPRI Board ..................................................................3-4  
Figure 3.9 Setting Switches of the TEPRI2 Board ..................................................................3-4  
Figure 3.10 PLIM Board..........................................................................................................3-4  
Figure 3.11 Mounting an Interface Board on a Slot.................................................................3-4  
Figure 3.12 Inserting a control Board to the Connector of the Main Board .............................3-4  
Figure 3.13 Connecting Power Fail Transfer to a 16SLI2/8SLI Board.....................................3-4  
Figure 3.14 Turning the Cabinet Power Off.............................................................................3-4  
Figure 3.15 Removing a Board ...............................................................................................3-4  
Figure 3.16 Replacing a New Board .......................................................................................3-4  
Figure 4.1 Connecting an External Battery...........................................................................4-4  
Figure 5.1 Connecting the Power (use of a cabinet)...............................................................5-4  
Figure 6.1 RJ-45 Port of 4TRM//8TRK Board .........................................................................6-4  
Figure 6.2 RJ-45 Port(T-Mode only) of 2BRM Board ..............................................................6-4  
XIV  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
Figure 6.3 RJ-45 Port of TEPRI Board................................................................................... 6-4  
Figure 7.1 RJ-45 Port of 4SLM Board .................................................................................... 7-4  
Figure 7.2 RJ-45 Port of 16SLI2 Board .................................................................................. 7-4  
Figure 7.3 RJ-45 Port of 8COMBO Board (for Analog Phone Connection) ............................ 7-4  
Figure 7.4 RJ-45 Port of 4DLM Board.................................................................................... 7-4  
Figure 7.5 RJ-45 Port of a 8DLI (for a digital phone).............................................................. 7-4  
Figure 7.6 RJ-45 Port of 8COMBO Board (for digital phone) ................................................. 7-4  
Figure 7.7 IP Phone Layout.................................................................................................... 7-4  
Figure 7.8 RJ-45 Port of Ethernet Connection Board............................................................. 7-4  
Figure 7.9 RJ-45 Port of 8DLI/16DLI2/8COMBO/4DLM Boards (for Door Phone) ................. 7-4  
Figure 7.10 Connecting MOH/BGM Sources ......................................................................... 7-4  
Figure 7.11 Connecting External/Additional Page Equipment ................................................ 7-4  
Figure 7.12 Connecting Common Bells.................................................................................. 7-4  
Figure 7.13 WebMMC Initial Screen....................................................................................... 7-4  
Figure 7.14 Connecting SMDR............................................................................................... 7-4  
Figure 7.15 Connecting Printers............................................................................................. 7-4  
LIST OF TABLES  
Table 1.1 Power Standards..................................................................................................... 1-4  
Table 1.2 Package Items........................................................................................................ 1-4  
Table 3.1 Mountable Boards on Slots..................................................................................... 3-4  
Table 3.2 Parts on the Rear Panel of the Cabinet .................................................................. 3-4  
Table 3.3 Switches of MP10/11 Board.................................................................................... 3-4  
Table 3.4 Control Board Types ............................................................................................... 3-4  
Table 3.5 Interface Board for Switche/Jumper Setting............................................................ 3-4  
Table 3.6 Interface Boards that can mount option boards ...................................................... 3-4  
Table 3.7 Interface Board Types and Available Slots.............................................................. 3-4  
Table 6.1 Line condition of OfficeServ 7100 ........................................................................... 6-4  
Table 7.1 Distance Between Stations and the System ........................................................... 7-4  
Table 7.2 Specification of the SMDR System ......................................................................... 7-4  
© SAMSUNG Electronics Co., Ltd.  
XV  
Ошибка! Стиль не определен.  
This page is intentionally left blank.  
XVI  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
CHAPTER 1. Before Installing  
This chapter describes items to check when inspecting the installation site and the  
grounding and power conditions before installing the OfficeServ 7100 system. This chapter  
also describes the items included in the OfficeServ 7100 package and the installation  
procedure.  
1.1 Site Information  
Select a site that satisfies the following conditions for safety, temperature and humidity:  
1.1.1 Safety Conditions  
y
y
y
The OfficeServ 7100 system should not be installed near materials that can cause a fire,  
such as explosive gas and inflammables.  
The OfficeServ 7100 system should not be near equipments that generate  
electromagnetic waves, such as monitors or copying machines.  
The installation location should be convenient for distributing trunk lines and  
extension lines, for connecting power and grounding wires, and for maintenance and  
repair.  
y
y
y
The OfficeServ 7100 system should not be installed in aisles or passageways that are  
populated or used for moving equipment.  
Always maintain cleanliness to prevent dust from damaging the board-connecting part  
of the cabinet.  
Before installing the OfficeServ 7100 system, check items such as the electric wiring  
status, grounding status, voltage and frequency.  
1.1.2 Temperature and Humidity  
y
The conditions for temperature and humidity are as follows:  
Operation Temperature: 0~40°C  
Storage temperature: -10~50°C  
Humidity: 10~90%  
y
y
Cool area without direct sunlight  
Ventilators should be installed to remove dust.  
© SAMSUNG Electronics Co., Ltd.  
1-1  
CHAPTER 1. Ошибка! Стиль не определен.  
1.2 Grounding Conditions  
y
y
The following cautions should be taken when grounding the OfficeServ 7100 system:  
The grounding wire of the OfficeServ 7100 system should be grounded to the earth  
using a proper material.  
y
y
The flow of electric current between the grounding wire of the power plug and the  
exposed metal surface of the system should be satisfactory.  
When connecting grounding of external additional equipments to the grounding of the  
system, the groundings should be connected through a single connection point.  
Cautions for Grounding  
- Do not connect the grounding wire of the OfficeServ 7100 system to a power  
conduit of a building.  
- The standards for power and grounding should comply with the country  
standard and the pertinent work should be conducted according to the country  
standard.  
- External grounding is required to prevent human injuries or system damages  
caused by lightning, static electricity, or voltage surge.  
- Unplug the AC power code before connecting the ground line. Failure to do so  
may cause bodily damage.  
- OfficeServ 7100 System should be connected to an outlet with a protective  
ground.  
- The GND in the back of the OfficeServ 7100 system should be grounded.  
1.3 Power Conditions  
The power supply board of the OfficeServ 7100 system receives AC input power or battery  
power, and supplies -54 V, -5 V, +5 V, +3.3 V, +12 V, and -54 V(Battery) to the system  
cabinet.  
The power condition is as follows:  
y
AC 220-240V, 1.5 A, 50/60 Hz, or DC 48 V, 3 A  
Table 1.1 Power Standards  
Power Supply  
Power Supply Input Power AC 230 V  
Unit(PSU)  
Standards  
Output  
Power  
- DC -54 V, 1.1 A  
- DC +5 V, 5 A  
- DC -5.3 V, 0.3 A  
- DC +3.3 V, 5 A  
- DC +12 V, 0.4 A  
- DC -54 V, 0.25 A(for backup)  
1-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
1.4 Checking the Package  
The list of items included in the OfficeServ 7100 package is as follows:  
Table 1.2 Package Items  
Category  
Name  
Basic Cabinet  
Quantity  
Remark  
Cabinet  
Cable  
1
1
1
1
3
2
1
-
-
-
Power Cable  
Battery Cable  
Items for  
19” Rack  
Installation  
Bracket for attaching Cabinet  
Screws for attaching Cabinet  
Other Screws  
Others  
Blank stiffener  
UTP Cable Types  
Available UTP cables are Straight-through UTP cable and Crossover UTP cable.  
The Straight-through UTP cable is used for connecting LIM module of the  
OfficeServ 7100 system to other modules such as MP10/11 and MGI.  
The Crossover UTP cable is only used for the connection between the LIM  
modules.  
© SAMSUNG Electronics Co., Ltd.  
1-3  
CHAPTER 1. Ошибка! Стиль не определен.  
This page is intentionally left blank.  
1-4  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
CHAPTER 2. Installing Cabinets  
This chapter describes how to install an OfficeServ 7100 cabinet on the ground, inside rack  
or on a wall depending on the installation environment.  
2.1 Procedure for the System Installation  
The procedure of system installation is as follows:  
1) Install the cabinet on the ground, inside rack or on a wall depending on the installation  
environment.  
2) Ground to the ground lug behind the basic cabinet.  
3) Insert the MP10/11 board into the slot 0 of the basic cabinet.  
4) Insert various interface boards into the universal slots(slot 1 and slot 2).  
5) Connect an external battery.  
6) Connect input power of AC 230 V..  
2.2 Selecting Installation Method  
The OfficeServ 7100 cabinet can be installed on the ground, inside a 19-inch rack or on a  
wall depending on the number of cabinets and environment of the installation area.  
© SAMSUNG Electronics Co., Ltd.  
2-1  
CHAPTER 2. Ошибка! Стиль не определен.  
2.3 Installing in a Rack  
This section describes how to install the OfficeServ 7100 cabinet inside a 19-inch rack.  
2.3.1 Cautions for Installation  
Take the following cautions when installing the OfficeServ 7100 cabinet inside a rack:  
y
y
The 19” rack should be a standard electric equipment rack.  
When using an enclosed-type rack, check if the rack is properly ventilated. Vents  
should be equipped on the side of the rack and fans should be attached to ventilate  
cool air into the rack.  
y
y
For the enclosed-type rack that the fan is attached on the top, beware that the hot-air  
generated in the system on the bottom part can go up and enters to the inlet port of the  
installed system.  
When using an open rack, do not block the entrance of a port or fan of the OfficeServ  
7100 system.  
2.3.2 Tools Required  
y
y
A middle-sized Phillips screwdriver  
Two brackets and six screws for  
attaching rack  
y
Two clamp screws  
Figure 2.1 Tools for the Installation inside a Rack  
2.3.3 Installing in a Rack  
The procedure for installing the OfficeServ 7100 cabinet inside a 19-inch rack is as  
follows:  
1) Attach the cabinet bracket to the bottom surface of the OfficeServ 7100 cabinet and  
fasten the bracket firmly with the two screws.  
Figure 2.2 Rack Installation (1)  
2-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
2) Slide the cabinet attaching the bracket in Step 1.  
Figure 2.3 Rack Installation (2)  
3) Align the two holes of the cabinet bracket and the holes of the rack brackets, and  
fasten the cabinet to the rack with the two screws.  
Figure 2.4 Rack Installation (3)  
© SAMSUNG Electronics Co., Ltd.  
2-3  
CHAPTER 2. Ошибка! Стиль не определен.  
2.4 Installing on a Wall  
This section describes how to install the OfficeServ 7100 cabinet on a wall.  
2.4.1 Tools Required  
y
y
y
y
y
y
y
Mid-sized Phillips screw driver  
Electric drill  
Hammer  
Wall-type bracket  
Four plastic anchors  
Four cross-type screws  
Four Mount locking screws  
Figure 2.5 Required Tools for the installation on a Wall  
2.4.2 Installing on a Wall  
The way to install the OfficeServ 7100 cabinet by using a wall-type bracket is as follows:  
1) There are four holes for the screws on the top/bottom of the bracket(A positions of the  
figure below). Mark four holes on a desired wall by using the bracket.  
A
A
Figure 2.6 Installation on a Wall (1)  
2-4  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
2) Make holes on the marked position of the wall-type bracket. Make the depths and the  
diameters of the holes more than 35 mm and around 5.5 mm to enable to insert the  
plastic anchors easily, respectively.  
Figure 2.7 Installation on a Wall (2)  
3) With a hammer, drive plastic anchors into the drilled holes.  
Figure 2.8 Installation on a Wall (3)  
4) Align the screw holes of the wall-type bracket to the position that the plastic anchors are  
driven. Insert screws to each hole and tighten the screws with a philips screw driver.  
Figure 2.9 Installation on a Wall (4)  
© SAMSUNG Electronics Co., Ltd.  
2-5  
CHAPTER 2. Ошибка! Стиль не определен.  
5) Two screws exists into the two screw holes among the four screw holes on the bottom side  
of the OfficeServ 7100 cabinet. Unscrew two screws with a screw driver about 2 mm.  
2 mm  
Figure 2.10 Installation on a Wall (5)  
6) Tighten the mount locking screws into the remained two holes among the four screw  
holes on the bottom of the OfficeServ 7100 cabinet. At this point, do not tighten  
completely, but remain the untightened part about 2 mm.  
Figure 2.11 Installation on a Wall (6)  
2-6  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
7) Align the screws on the bottom of the OfficeServ 7100 cabinet to the bracket holes,  
then pull down the cabinet to fix the cabinet completely.  
2 mm  
Figure 2.12 Installation on a Wall (7)  
© SAMSUNG Electronics Co., Ltd.  
2-7  
CHAPTER 2. Ошибка! Стиль не определен.  
2.5 Connecting the Grounding Wire  
This section describes how to connect an external grounding wire to the OfficeServ 7100  
system.  
External Grounding  
External grounding is required to prevent human injuries or system damages  
caused by lightning, static electricity, or voltage surge.  
The OiiceServ 7100 system has to be grounded by big electric wire more  
than a cross-sectional area is 4.0mm2. The Screw should be minimum 3.5  
mm nominal thread diameter and Ring Terminal should be UL Listed Lug  
Terminal used.  
As shown in the figure below, ground to the ground lug behind the OfficeServ 7100.  
Figure 2.13 Grounding  
Checking external grounding  
After installing the OfficeServ 7100 system, make sure that the GND in the back  
side of the system cabinet is connected to the external ground for communication  
before the operation.  
2-8  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
CHAPTER 3. Mounting and Replacing  
Boards  
This chapter describes how to mount and replace various boards of the OfficeServ 7100  
system.  
3.1 Cabinet Configuration  
The cabinet of the OfficeServ 7100 System has three slots that can install boards.  
Front  
Slot 0  
Slot 1  
Slot 2  
Rear  
Figure 3.1 Front/rear View of OfficeServ 7100 Cabinet  
© SAMSUNG Electronics Co., Ltd.  
3-1  
CHAPTER 3. Ошибка! Стиль не определен.  
Following boards are mounted on the slots according to the configuration of the OfficeServ  
7100.  
Table 3.1 Mountable Boards on Slots  
Cabinet  
Slot  
Mountable Board  
Control Part  
Slot 0  
Slot 1 and Slot 2  
MP10, MP11  
Subscriber  
Part  
- OS 7100 Card: UNI board  
- OS 7200 Card: 8/16DLI2, 8/16SLI2, 8COMBO, 8TRK,  
TEPRI, LIM, MGI,  
(UNI)  
- OS7400 Card: TEPRI2, MGI64  
The descriptions about each part on the rear of the cabinet are listed in the table below.  
Table 3.2 Parts on the Rear Panel of the Cabinet  
Part  
Power Switch  
Function  
Power on/off the OfficeServ 7100 system.  
Connector for the power cable connection  
The LED indicates the input of AC power.  
The LED indicates the normal output of DC power.  
Socket to connect an external battery  
Power I/O Switch  
AC LED  
DC LED  
Battery Socket  
Ground Lug  
Lug for the ground of the system communication  
3-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
3.2 Mounting Control Boards  
This section describes how to set the switches of MP10/11 control board, mount the option  
boards, insert to the slots and connect MP10/11 board.  
3.2.1 Setting Switches and Mounting Option Boards.  
MP10/11 has the switches to set the board operation for the user’s purpose and fitting with  
the system configuration. The way to set the switches and mount the boards are as follows:  
1) Set S1 switch of the MP10/11 board as On and Pin 1 to Pin 4 of S2 switch as Off.  
Pin 6 to Pin 8 are set depending on the user’s purpose.  
S2  
On  
Off  
S1  
Off  
On  
Figure 3.2 Setting Switches of MP10/11 Board  
Table 3.3 Switches of MP10/11 Board  
Switch  
S1  
Description  
Set S1 as On before mounting on the slot for memory backup.  
If switched On when the switch is Off. all data in the database are automatically  
initialized. To store the data in the database, operate the system after turning on the  
S1 switch.  
S2  
SW1~SW4  
SW6~SW8  
the pins are set the country code that the system will be used.  
Sets the number of digits for C.O./extension lines and extension.  
[ Not-used : Always default 3 digits ]  
SW6-On: 4 digits for C.O. line  
Off: 3 digits for C.O. line  
SW7-On: 4 digits for an extension group  
Off: 3 digits for an extension group  
SW8-On: 4 digits for an extension number  
Off: 3 digits for an extension number  
© SAMSUNG Electronics Co., Ltd.  
3-3  
CHAPTER 3. Ошибка! Стиль не определен.  
2) A modem board is mounted to connector P7/P8 of the MP10/11 board.  
When mounting a modem board, the holes on the corners of the modem should be  
aligned fitting with the spacer.  
MODEM  
Figure 3.3 Mounting a Modem Board on the MP10/11 Board  
4SWM or 4DLM can be mounted to connector P11, P12 and P13 of the MP10/11  
board. Screws are basically locked to the support beside P13. Unscrew and position the  
screws to the connector direction of 4SWM/4DLM before mounting 4SWM/4DLM.  
After that, tighten the screws fitting with the grooves of 4SWM/4DLM.  
4SWM  
Figure 3.4 Mounting 4SWM/4DLM on the MP10/11 Board  
3-4  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
3.2.2 Mounting Control Boards  
Mount a control board to the slot 0 of the OfficeServ 7100 cabinet. For the locations of slot  
0 to slot 2, refer to ‘3.1. Cabinet Configuration’.  
Table 3.4 Control Board Types  
Control Board  
Mountable Slot  
MP10/11  
Slot 0 of the Basic Cabinet  
Mount the MP10/11 board as follows:  
1) Check if the MP10/11 board to be mounted is damaged.  
Caution for the power when mounting boards  
Check if the cabinet power is off when mounting boards on slots. Inserting or  
ejecting a board while the power is on may damage the board or cause fire.  
2) Align the MP10/11 board to the guardrail of slot 0 of the basic cabinet, and slide the  
board into the slot with care.  
Figure 3.5 Mounting the Control Board to Slot 0  
3) Press and lock the lever on the front panel of the MP10/11 board to fully insert to the  
connector of the OfficeServ 7100 connector.  
Figure 3.6 Inserting the Control Board to a connector of the Main Board  
© SAMSUNG Electronics Co., Ltd.  
3-5  
CHAPTER 3. Ошибка! Стиль не определен.  
3.3 Mounting Interface Boards  
This section describes how to set jumpers and switches of an interface board, how to mount  
optional boards to an interface board, and how to mount interface boards into slots.  
3.3.1 Setting Switches and Mounting Optional Boards  
These interface boards are divided into the boards to set switches or jumpers and the boards  
to mount option boards.  
Table 3.5 Interface Board for Switches/Jumper Setting  
Interface Board  
TEPRI  
Jumper/Switch Setting  
Jumper/Switch Function  
S1(SW1~SW8)  
Setting E1, T1/E1/PRI, 24B+D/24B,  
User/Network and 17H/13H  
TEPRI2  
S2(1~4)  
S3(1~4)  
Setting T1, E1, T1/E1,PRI, 24B+D/24B,  
User/Network and 1AH  
TEPRI(a/2) Cards is only support E1(1) PRI function, but not supports for  
E1(T1) Digital Trunk function.  
Table 3.6 Interface Boards that can mount option boards  
Interface Board  
Option Board  
MP10(MP11)  
UNI  
4DLM or 4SWM, MODEM  
4TRM, 2BRM, 4DLM, 4SLM  
4SWM Module board supports not 10M LAN interface but 100M LAN interface.  
4TRM Module board supports not Dial Pulse dialing but DTMF dialing. 8TRK  
Card supports DTMF and Dial Pulse dialing  
3-6  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
3.3.1.1 Mounting UNI Board  
The UNI board has three connectors to mount option boards and the mountable modules  
are 4TRM, 2BRM, 4DLM and 4SLM. For user’s purpose, up to three modules can be  
mounted regardless of the type of the option module. Module1, Module2 and Module3 are  
positioned on the basis of the front panel of the UNI board, and the interface of the  
corresponding module is marked on the front panel of the UNI board.  
Align the module to be mounted to the top connector(16-pin connector). After that, match  
the bottom connector(100-pin connector). Mount two connectors grasping both connectors.  
Lock the supporter between the grooves and the top of each option board with screws.  
4SLM  
4TRM  
Figure 3.7 Mounting the UNI Board  
© SAMSUNG Electronics Co., Ltd.  
3-7  
CHAPTER 3. Ошибка! Стиль не определен.  
3.3.1.2 TEPRI Boards  
Set the S1 switch of the TEPRI board as follows:  
S1  
S1  
OFF  
ON  
SW1  
On  
SW 1  
E1  
T1  
SW8  
SW 2  
T1/E1  
PRI  
24B  
Off  
SW 3  
24B + D  
User  
SW 4  
SW 5  
Network  
Not-used  
AFT(Automatic  
Function Test)  
Not-used  
Not-used  
13H  
SW 6  
SW 7  
SW 8  
Not-used  
Not-used  
17H  
Figure 3.8 Setting the Switch of the TEPRI Board  
3-8  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
3.3.1.3 TEPRI2 Board  
T1E1PRI2(TEPRI2) board, which provides a digital C.O. line, supports two ports for each  
E1, T1 and ISDN PRI and provides the Q-SIG function.  
Set S2 and S3 switches and jumpers of the TEPRI2 board as follows:  
Setting Switches  
1
1
J2  
1
J1  
1
J4  
J3  
ON  
4
1
OFF  
S2  
4
1
S3  
S2  
1
OFF  
ON  
E1  
T1  
2
T1/E1  
24B + D  
User  
PRI  
3
24B  
4
Network  
ON  
S3  
1
OFF  
Not-used  
T1/E1  
Not-used  
PRI  
2
3
24B + D  
User  
24B  
4
Network  
Figure 3.9 Setting Switches of the TEPRI2 Board  
Setting Jumpers  
J1, J2, J3 and J4: Connect #1 and #2 for E1 cable, #2 and #3 for T1 cable  
© SAMSUNG Electronics Co., Ltd.  
3-9  
CHAPTER 3. Ошибка! Стиль не определен.  
3.3.1.5 PLIM Board  
The OfficeServ 7100 system does not support the power to the PLM board. Therefore, the  
PLIM board does not support PoE and only performs the same function as that of the LIM  
board.  
When the PLIM board is used, the board should be mounted after removing Shunt pin J1,  
J2 and J3 supplying the PoE Power.  
1
1
1
J3  
J2  
J1  
Figure 3.10 PLIM Board  
3-10  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
3.3.2 Mounting Interface Boards to Slots  
The interface boards are mounted to Slot 1 and Slot 2 of the cabinet. The available slot  
positions ‘3.1 Cabinet Configuration’.  
Table 3.7 Interface Board Types and Available Slots  
Category  
Interface Board  
TEPRI, TEPRI2  
Slots Available  
Voice C.O. line  
Slot 1 and Slot 2 of the cabinet  
Slot 1 and Slot 2 of the cabinet  
Slot 1 and Slot 2 of the cabinet  
Slot 1 and Slot 2 of the cabinet  
Slot 1 and Slot 2 of the cabinet  
8TRK, UNI  
Voice extension  
16DLI2, 8DLI, 16SLI2, 8SLI, 8Combo, UNI  
Data voice  
application  
MGI, MGI64  
LIM  
References  
For the detailed features and functions for each interface board, refer to ‘OfficeServ  
7200 System manual’.  
The Procedure for mounting the interface board to each slot is as follows:  
1) Check the exterior of the interface board for any damages.  
2) Align each Interface board to the guardrail of the universal slot of the OfficeServ 7100  
basic cabinet or expansion cabinet, and slide the Interface board into the slot.  
Figure 3.11 Mounting an Interface Board on a Slot  
© SAMSUNG Electronics Co., Ltd.  
3-11  
CHAPTER 3. Ошибка! Стиль не определен.  
3) Press and lock the lever on the front panel of the interface board to fully insert to the  
connector of the OfficeServ 7100 main board.  
Figure 3.12 Inserting a control Board to the Connector of the Main Board  
3-12  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
3.4 Connecting Power Fail Transfer  
4TRM and 4SLM option boards do not support Power Fail Transfer function.  
If AC power is fails while battery is not connected, connect a power fail transfer circuit by  
connecting C.O. lines to extensions. If a pair of trunk lines(8TRK) is connected to pin1 and  
pin2 of the first port in 16SLI2 or 8SLI, the lines are connected to a typical phone through  
Pin 4 and 5 in 8TRK. In power failure, emergency calls can be available since the C.O. line  
is directly connected to the phone by the internal relay operation.  
Figure 3.13 Connecting Power Fail Transfer to a 16SLI2/8SLI Board  
© SAMSUNG Electronics Co., Ltd.  
3-13  
CHAPTER 3. Ошибка! Стиль не определен.  
3.5 Replacing Boards  
If the OfficeServ 7100 system fails to operate normally due to an error on the power supply  
board, control board, or interface board, replace the board to a new one.  
Removing Cables  
Replace a board after removing all cables connected to the board.  
The procedure for replacing a board mounted in a slot of a cabinet is as follows:  
1) Turn off the power of the cabinet equipped with the board to be removed.  
Figure 3.14 Turning the Cabinet Power Off  
2) Extract the board by pulling the lever of the board carefully.  
Figure 3.15 Removing a Board  
3-14  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
3) Align the new board to the guardrail of the slot, and slide the new board into the slot.  
After then, lock the lever in the front panel of the board to fully insert into the  
connector of the OfficeServ 7100 main board.  
Figure 3.16 Replacing a New Board  
© SAMSUNG Electronics Co., Ltd.  
3-15  
CHAPTER 3. Ошибка! Стиль не определен.  
This page is intentionally left blank.  
3-16  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
CHAPTER 4. Connecting External  
Batteries  
This chapter describes how to connect external batteries.  
4.1 Cautions for Connecting External Batteries  
y
External batteries are required to ensure stable operation of the OfficeServ 7100  
system in case a power failure occurs. The rated capacity of an external battery is DC  
48V per cabinet. Batteries should be connected to each cabinet to guarantee safety and  
a fuse(125 VAC, 5 A) should be positioned between the output terminal of the battery  
and the battery connector of the cabinet  
Cautions for connecting an external battery  
Do not connect external AC power to the system before connecting an external  
battery to the system. To do so, may cause electric shock for the system or the  
constructor.  
Make sure that the polarities(+/-) between the external battery ant the system are  
equal.  
To reduce risk of fire and injury to persons, use only a sealed nickel cadmium or  
lead-acid battery supply capable of handling a charge current of 0.25 A, a charge  
voltage of -54 V dc and a discharge rate of 26 Ah.  
y
© SAMSUNG Electronics Co., Ltd.  
4-1  
CHAPTER 4. Ошибка! Стиль не определен.  
4.2 Connecting External Batteries  
The procedure for using a battery cable to connect an external battery to the OfficeServ  
7100 system is as follows:  
1) Prepare the battery cable that was provided with the OfficeServ 7100 system. An end  
of this battery cable consists of a white line and a black line.  
2) Connect the white line of the battery cable to the (+) terminal, and the black line to the  
(-) terminal of the battery. Then, connect the other end of the battery cable to the  
external battery socket on the rear panel of the OfficeServ 7100 cabinet. When using  
two or more OfficeServ cabinets, prepare as much external batteries as the number of  
cabinets and connect the batteries to each cabinet.  
Figure 4.1 Connecting an External Battery  
4-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
CHAPTER 5. Connecting the Power  
This chapter describes how to connect power to the OfficeServ 7100 system.  
5.1 Cautions when Connecting Power  
When input power is normally supplied, the AC power is supplied to the Power Supply  
Unit(PSU), which charges the external battery. If the input power is interrupted, the system  
can be operated using the charged power of the external battery.  
Cautions to be taken when connecting power to the OfficeServ 7100 system are as follows:  
y
y
AC power of the system only supports 230V.  
A single AC outlet should be used solely for the system’s AC power. Sharing the AC  
power with other devices can cause noise or a voltage drop, resulting in a system  
malfunction or fire.  
y
Use a stable power source that can always supply AC power since instantaneous  
power failures can cause malfunctions or battery failures. Procedure for Connecting  
Power.  
© SAMSUNG Electronics Co., Ltd.  
5-1  
CHAPTER 5. Ошибка! Стиль не определен.  
5.2 Connecting the Power  
Single cabinet configuration  
Use the power cable provided with the OfficeServ 7100 system to connect the input power  
terminal on the back panel of the basic cabinet to a grounded outlet.  
Figure 5.1 Connecting the Power (use of a cabinet)  
5-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
CHAPTER 6. Connecting C.O. Line  
This chapter describes how to connect the C.O. line to the OfficeServ 7100 system after  
installation.  
6.1 Line Conditions  
Cautions for connecting C.O. lines are as follows:  
y
y
y
y
y
Us the cables with AWG #24 or AWG #26 thickness.  
When wiring cables in high-humidity areas, remove moisture before wiring.  
Cables should be handled carefully to prevent any distortions or damages.  
Subscriber lines should be kept indoors if at all possible.  
Do not cable subscriber lines around any high-voltage power line.  
Leak resistance for the C.O. line connected to the OfficeServ 7100 system is as follows:.  
Table 6.1 Line condition of OfficeServ 7100  
Line Condition  
Leak Resistance  
20 kΩ or higher  
20 kΩ or higher  
Leak Resistance between Lines  
Leak Resistance Between Grounds  
© SAMSUNG Electronics Co., Ltd.  
6-1  
CHAPTER 6. Ошибка! Стиль не определен.  
6.2 Connecting the C.O. Line  
This section describes how to connect a common C.O. line(4TRM/2BRM of the UNI and  
8TRK board) and PRI C.O. lines(TEPRI/TEPRI2 board).  
6.2.1 Cautions to Connect the C.O. Line  
Cautions to prevent bodily injuries and system damages when connecting the C.O. line are  
as follows:  
y
Do not connect the C.O. line in extreme weather conditions such as storm and  
lightning.  
y
Do not connect the C.O. line in areas with moisture.  
6.2.2 Connecting Common C.O. Line  
Use a pair of AWG #24(or AWG #26) cable to connect a common C.O. line to the terminal  
pin of a terminal box connected to the OfficeServ 7100 system equipped with a 4TRM or  
2BRM board.  
P1-P4 Ports  
(RJ-45)  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
-
-
C.O TIP  
C.O RING  
-
-
-
Figure 6.1 RJ-45 Port of 4TRM//8TRK Board  
P1, P2 Ports  
(RJ-45)  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
-
TX +  
RX +  
RX -  
TX -  
-
-
Figure 6.2 RJ-45 Port(T-Mode only) of 2BRM Board  
6-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
6.2.3 Connecting T1/E1/PRI  
TEPRI boards can be connected to a T1/E1 C.O. line through a RJ-45 port.  
As shown below, connect a T1 type C.O. line or an E1 type PRI C.O. line to the T1/E1/PRI  
port of the TEPRI/TEPRI2 built in the OfficeServ 7100 system.  
T1/E1/PRI Port  
(RJ-45)  
Pin No.  
1
2
3
4
5
6
7
8
E1 Mode  
Function  
-
-
-
Tx+  
Tx-  
-
Rx-  
Rx+  
Figure 6.3 RJ-45 Port of TEPRI Board  
© SAMSUNG Electronics Co., Ltd.  
6-3  
OfficeServ 7100 Installation Manual  
CHAPTER 7. Connecting Stations and  
Additional Equipment  
This chapter describes how to connect various stations and additional equipment, such as  
analog/digital phones, door phones and door locks.  
7.1 Connecting Stations  
7.1.1 Cautions for Connecting Stations  
Take the following cautions when connecting stations:  
y
y
y
Do not connect stations in weather conditions such as storm and lightning.  
Do not connect stations in a humid area.  
Comply with the manual of the station and with this document when reconnecting  
stations or changing connections.  
y
Connect stations to a pair of #24 AWG or #26 AWG cables.  
The distances between stations and the OfficeServ 7100 system are as follows:  
Table 7.1 Distance Between Stations and the System  
Installation Distance  
Digital Phone  
Standards  
Maximum 400 m(for AWG #24)  
Maximum 1 km(for AWG #24)  
Maximum 400 m(for AWG #24)  
Maximum 400 m(for AWG #24)  
Analog Phone  
Door Phone  
AOM  
© SAMSUNG Electronics Co., Ltd.  
7-1  
CHAPTER 7. Ошибка! Стиль не определен.  
7.1.2 Connecting Analog Phones  
Connect an analog phone to the 4SLM of the UNI board, 8SLI/16SLI2, 8COMBO or UNI  
board mounted on the OfficeServ 7100 system.  
Connecting to the 4SLM of a UNI Board  
Connect an analog phone to the ports of a 4SLM of the UNI board by using a pair of AWG  
#24 or AWG #26 cables.  
P1-P4 Ports  
(RJ-45)  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
SLI  
TIP  
SLI  
-
-
-
RING  
Figure 7.1 RJ-45 Port of 4SLM Board  
Connecting to a 8SLI/16SLI2 Board  
Connect an analog phone to the port of a 16SLI board by using a pair of AWG #24 or AWG  
#26 cables.  
P1-P8 Ports  
(RJ-45)  
P1 Port  
Pin No.  
1
2
3
4
5
6
7
8
Function  
PFT  
TIP  
PFT  
TIP  
-
SLI 1  
TIP  
SLI 1  
RING  
-
PFT  
TIP  
PFT  
TIP  
(8SLI)  
(8SLI)  
(16SLI2) (16SLI2)  
P2-P16 Ports  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
-
-
SLI  
TIP  
SLI  
-
RING  
Figure 7.2 RJ-45 Port of 16SLI2 Board  
7-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
Connecting to a 8COMBO Board  
Connect an analog phone to the ports of a 8COMBO board by using a pair of AWG #24 or  
AWG #26 cables.  
P1-P8 Ports  
(RJ-45)  
P1-P8 Ports  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
-
-
SLI TIP  
SLI  
-
RING  
Figure 7.3 RJ-45 Port of 8COMBO Board (for Analog Phone Connection)  
© SAMSUNG Electronics Co., Ltd.  
7-3  
CHAPTER 7. Ошибка! Стиль не определен.  
7.1.3 Connecting Digital Phones  
Connect a digital phone to the 4DLM of the UNI board, 8DLI, 16DLI2 and 8COMBO  
board.  
Connecting to the 4DLM of a UNI Board  
Connect an analog phone to the ports of a 4DLM of the UNI board by using a pair of AWG  
#24 or AWG #26 cables.  
P1-P4 Ports  
(RJ-45)  
P1-P4 Ports  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
DLI  
TIP  
DLI  
-
-
-
RING  
Figure 7.4 RJ-45 Port of 4DLM Board  
Connecting to a 8DLI/16DLI2 Board  
Connect a digital phone to the ports of a 8DLI board by using a pair AWG #24 or AWG  
#26 cables.  
P1-P8(P16)  
Ports  
(RJ-45)  
P1-P16 Ports  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
-
-
DLI  
TIP  
DLI  
-
-
-
RING  
Figure 7.5 RJ-45 Port of a 8DLI (for a digital phone)  
7-4  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
Connecting to a 8COMBO Board  
Connect a digital phone to the ports of the 8COMBO board by using a pair AWG #24 or  
AWG #26 cables.  
P1-P8 Ports  
(RJ-45)  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
-
-
DLI TIP  
DLI  
-
RING  
Figure 7.6 RJ-45 Port of 8COMBO Board (for digital phone)  
Maximum number of DS-5012L phones connectable  
Up to eight DS-5012L phones can be connected to each DLI board(8DLI/16DLI2)  
of the OfficeServ 7100 system. If more than eight DS-5012L phones are  
connected to the DLI board, the power for all digital phones connected to the  
same board is blocked automatically. Up to 24 DS-5012L phones can be  
connected to the basic cabinet or the expansion cabinet.  
© SAMSUNG Electronics Co., Ltd.  
7-5  
CHAPTER 7. Ошибка! Стиль не определен.  
7.1.4 Connecting IP Phones  
IP phone is a phone that provides calls through Ethernet LAN. The interface between a  
digital phone connected to the OfficeServ 7100 system and an IP phone connected to LAN  
is as follows. In default, the MP10/11 board supports eight MGI channels. Therefore, IP  
phones are available even if additional MGI16/MGI64 boards are not mounted.  
1) The connection between a digital phone and an IP phone is established or released  
using the IP address of the LAN connected to the OfficeServ 7100 system.  
2) The digital phone connected to the OfficeServ 7100 system converts the analog voice  
data to PCM voice data and transmits the data to the MP10/MP11 or MGI boards via  
through 16 DLI2 board  
3) PCM voice data is converted to packet data by the MP10/MP11 board and transferred  
to the IP phone.  
4) The IP phone converts packet voice data to analog voice signals and displays the  
signals through a handset or a speaker.  
5) Voice signals coming from the IP phone is converted to packet data and transmitted to  
the MP10/MP11 or MGI board in the same way. The MP10/MP11 or MGI board  
converts the packet voice data to PCM voice data and transmits the data to the digital  
phone through the 16DLI2 board. The digital phone converts and sends the PCM voice  
data to analog data.  
Use after the MMC setting suitable for the system.  
OfficeServ 7100  
MP10  
16DLI  
IP Telephone  
Digital Telephone  
Figure 7.7 IP Phone Layout  
7-6  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
7.1.4.1 Connecting Boards to Ethernet  
LIM/MGI/MGI64/MP10/MP11/4SWM board can be connected to Ethernet by using an  
Ethernet cable  
RJ-45 Port  
y
y
y
LIM Board-All ports(P1~P16)  
4SWM Board-Line Ports(P1~P4)  
MP10/11, MGI16/MGI64 Board-LAN Port  
Pin No.  
1
2
3
4
5
6
7
8
Function  
Tx+  
Tx-  
Rx+  
-
-
Rx-  
-
-
Figure 7.8 RJ-45 Port of Ethernet Connection Board  
7.1.5 Connecting to a Door Phone and a Door Lock  
Connect a door phone and a door lock to the OfficeServ 7100 system by using a Door  
Phone Interface Module(DPIM). Connect a pair of #24 AWG or #26 AWG cables to the  
LINE port of DPIM and the ports of 8DLI/16DLI2/8COMBO/4DLM board of the  
OfficeServ 7100 system.  
Connecting to 8DLI/16DLI2/4DLM Boards  
Pin No.  
1
2
3
4
5
6
7
8
Function  
-
-
-
DLI TIP  
DLI  
-
-
-
RING  
Figure 7.9 RJ-45 Port of 8DLI/16DLI2/8COMBO/4DLM Boards (for Door Phone)  
1) Connect the Door port of DPIM and the line port of DOOR BOX port.  
2) When using an automatic door lock, connect the Lock port of the DPIM and the door  
phone contact point to the door lock.  
The door lock contact point is designed to control low-voltage relay and uses 24 VDC and  
100 mA.  
MMC Related  
MMC 211 is used to assign call numbers to door phones.  
© SAMSUNG Electronics Co., Ltd.  
7-7  
CHAPTER 7. Ошибка! Стиль не определен.  
7.2 Connecting Additional Equipment  
This section describes how to connect optional equipment, such as Music on  
Hold(MOH)/Background Music(BGM) sources, external page devices and common bells,  
to the OfficeServ 7100 system.  
7.2.1 Connecting MOH/BGM Equipment  
The OfficeServ 7100 system offers music when while on hold.  
The system provides internal tone/music and external music sources per C.O. or extension  
lines as the music source. The selection of internal/external music sources is performed  
through MMC 861. One external music source is provided while on hold, and the external  
music source is connected to the MISC port.  
If a pair of MOH/BGM Source lines is connected to pin4 and pin5 of the MISC port in  
MP10(MP11).  
MOH/BGM source of a user  
Figure 7.10 Connecting MOH/BGM Sources  
MMC Related  
Select music sources for C.O. lines through MMC 408 and music sources for  
extensions through MMC 308. If external music source will be used, select this  
option through MMC 861 (default is internal).  
7-8  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
7.2.2 Connecting External/Additional Page Equipment  
Instead of an internal speaker, external broadcasting equipment, such as amps or speakers,  
and additional equipment that can broadcast page(ring) signals outside a building can be  
connected to the OfficeServ 7100 system. Connect external/additional page equipment to  
the MISC port of the MP10/MP11 board mounted on the OfficeServ 7100 system. The  
power of the external/additional page equipment should be separately connected.  
The OfficeServ 7100 system supports the channels for external broadcasting and one dry  
contact. If a pair of External Page Equipment lines is connected to pin3 and pin6, Dry  
Contact 1 lines is connected to pin1 and pin2, Dry Contact 2 lines is connected to pin7  
and pin8 of the MISC port in MP10(MP11).  
Dry Contact  
(for Common bell)  
External Page Equipment  
Figure 7.11 Connecting External/Additional Page Equipment  
Dry Contact  
Dry Contact is a switch that can connect or cut the power or line to external  
equipment.  
7.2.3 Connecting Common Bell  
Common Bell is the ring type. So, when a ring is received through an extension of a group,  
all extensions of the group also receive the ring.  
To use common bell, connect the common bell to the MISC port mounted on the  
OfficeServ system. The OfficeServ 7100 system supports only one dry contact for the  
common bell.  
Dry contact  
(For common bell)  
Figure 7.12 Connecting Common Bells  
© SAMSUNG Electronics Co., Ltd.  
7-9  
CHAPTER 7. Ошибка! Стиль не определен.  
7.2.4 Changing System Setting  
Since the OfficeServ 7100 system is equipped with the web server of WebMMC, it  
supports the remote access through the network. The system administrator can change the  
system setting after getting access to WebMMC by using a browser.  
This section describes how to access the OfficeServ 7100 system.  
If the in-housing network is established, connect LAN to the LAN port of the MCP board  
and attempt the access in a client PC.  
Setting Network parameter by using the MMC830 program  
Set the network parameter of the OfficeServ 7100 system. For the setting value of the  
network parameter, contact the network administrator.  
1) Set the IP address of the OfficeServ 7100 system.  
2) Set the subnet mask of the OfficeServ 7100 system.  
3) Set the gateway address of the OfficeServ 7100 system.  
4) Reset the board.  
About the board reset  
To apply new setting, the board should be reset.  
7-10  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
Getting access to WebMMC from a client PC  
1) Execute your browser.(Internet Explorer 5.0 or higher)  
2) Access WebMMC by using the LAN IP address.  
Access address: http://[System LAN IP Address]  
Figure 7.13 WebMMC Initial Screen  
3) Enter your ID and password on the WebMMC initial screen, and click the [OK] button  
for login.  
7.2.5 Connecting SMDR  
The Station Message Detail Recording(SMDR) computer is used for recording call  
information and for calculating phone bills or displaying various analysis data based on the  
call data provided by the system.  
The SMDR computer can be connected via the LAN port of the 4SWM board or the  
MP10/11 board built in the OfficeServ 7100 system.  
SMDR system specification is as follows:  
Table 7.2 Specification of the SMDR System  
Category  
Specification  
Platform  
IBM PC  
CPU  
Pentium 586 or higher  
Windows 95/98 r later  
32 MB or more  
Operating System  
Main Memory  
© SAMSUNG Electronics Co., Ltd.  
7-11  
CHAPTER 7. Ошибка! Стиль не определен.  
If LAN is established within the company, connect LAN to the LAN port of the MP10/11  
board and a SMDR computer to the LAN.  
MCP  
LAN  
OfficeServ 7100  
SMDR  
Figure 7.14 Connecting SMDR  
7.2.6 Connecting Printers  
The OfficeServ 7100 system can connect to printers. The system can print various call  
information or event information created by the system in real time whenever an event  
occurs.  
If LAN is established within the company, connect LAN to the LAN port of the MP10/11  
board and a printer to the LAN. If the 4SWM is built in the MP10/11, a printer can be  
connected to the LAN port of the 4SWM.  
MCP  
LAN  
OfficeServ 7100  
Printer  
Figure 7.15 Connecting Printers  
MMC Related  
After connecting a printer, execute MMC 804 and enter the I/O port through which  
the printer is connected.  
7-12  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
CHAPTER 8. Starting the System  
This chapter describes items to check before starting the OfficeServ 7100 system, the procedure  
for starting the system, and the procedure to test the operation of the system.  
8.1 Pre-Check  
This section describes items to check before starting the OfficeServ 7100 system.  
8.1.1 Environment  
y
y
y
Temperature  
Check if the room temperature is between 0°C and 40oC. If the room temperature is  
out of range from the normal operation temperature, install a heating/cooling device to  
maintain the normal operation temperature.  
Humidity  
Check if the humidity of the room where the system is installed is between 10% and  
90%. Take special caution since humidity affects the electric components and  
connectors of the system.  
Direct Sunlight and Dust  
The room where the OfficeServ 7100 system is installed should be protected from  
direct sunlight and should have ventilation systems to prevent the system from  
malfunctioning due to dusts.  
© SAMSUNG Electronics Co., Ltd.  
8-1  
CHAPTER 8. Ошибка! Стиль не определен.  
8.1.2 Safety Conditions  
The building where the OfficeServ 7100 system is installed should have lightning rods and  
grounding to protect the system against lightning and electric leakage.  
y
y
y
Check if the OfficeServ 7100 system is not inclined and is maintained horizontally.  
Do not place devices that may cause electromagnetic interference near the system.  
Place a fire extinguisher near the system. Since spring coolers can seriously damage  
the system, use extinguishers such as Halor 1301 and Carbon Dioxide.  
y
y
y
Make sure that the input power of the OfficeServ 7100 system should be AC 230 V  
and do not use together with other electric devices, such as motors and compressors.  
Check if the AC voltage switch of the PSU is properly set according to the voltage of  
the input power, 230 VAC.  
Check if the grounding terminal on the rear panel of the system is properly connected  
to the external grounding.  
8-2  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
8.2 Starting the System  
The procedure for starting the OfficeServ 7100 system is as follows:  
1) Check if the boards and cables are properly mounted and connected to the OfficeServ  
7100 cabinet.  
2) Turn on the power of the OfficeServ 7100 basic cabinet, and turn on the power of the  
expansion cabinet.  
3) Check the LEDs for the MP10/11 boards mounted on the OfficeServ 7100 cabinet.  
y The RUN LED of the MP10/11 board turns green and the MC LED flashes when  
the system normally starts the booting process.  
y Once the booting is complete, the RUN LED of the MP10/11 board flashes green,  
and the SM LED stops flashing and remains lighted.  
y The RUN LED of the LCP board flashes when the power supply and processor  
status of the expansion rack is normal.  
If the Multi Media(MMC Card) is not detected  
If the system cannot detect the multi media, the MC LED of the MP10/11 board flash  
in red. In such cases, remove MMC card from MP10/11 boards and insert it again.  
4) Check if the LED statuses of other interface boards are normal.  
5) If the LED status of a MP10/11 or interface board is abnormal, turn off the power of  
the cabinet and turn the power on again.  
Board LED Status & Shut-down  
- Refer to the ‘OfficeServ 7100 System Manual’ for LED statuses of each board.  
- Shut-down is hardly required while operating the OfficeServ 7100 system.  
However, when shutting down the system due to reasons such as moving the  
system, turn off the power of the expansion cabinet, and turn off the power of  
the basic cabinet.  
© SAMSUNG Electronics Co., Ltd.  
8-3  
CHAPTER 8. Ошибка! Стиль не определен.  
8.3 Numbering Extensions and C.O. Lines  
Once the OfficeServ 7100 system is booted, the MP10/11 board verifies the boards  
mounted on each slot and saves this information as the default configuration of the system.  
C.O. line numbers from 701 are sequentially assigned to the C.O. line board mounted on  
Slot 1 of the basic cabinet, and following numbers are continuously assigned to the next  
board of the next slot. This numbering process continues until the C.O. line numbers are  
assigned to all C.O. lines. However, only the numbers from 701 to 799 are assigned when using  
3 digits  
Extension numbers from 201 are sequentially assigned to the extension board mounted on  
Slot 1 of the basic cabinet, and following numbers are continuously assigned to the next  
extension board of the next slot. This numbering process continues until the extension  
numbers are assigned to all extensions. However, only the numbers from 201 to 349 are  
assigned when using 3 digits.  
The last port of the first 8DLI or 16DLI2 board is assigned to the attendant group as default.  
All C.O. lines ring this attendant extension unless the default value is changed. Thus, a  
phone with an LCD panel should be connected to the last port of the first 8DLI board.  
Numbers between 500-549 are assigned to an extension group.  
The numbers of C.O. lines, extensions, or extension groups can be changed using the MMC  
724 program.  
8-4  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
8.4 Checking System Operation  
After starting the OfficeServ 7100 system, check if the system is operating normally.  
Check if the basic functions of the OfficeServ 7100 system, such as Station Call, Station  
Camp-On, C.O. Line Call, and C.O. Line Camp-On are properly executed.  
8.4.1 Station Call Function  
First, follow the procedure below and check if calls between stations are enabled:  
1) Lift the handset of a station.  
Verify the intercom dial tone.  
2) Press an extension number.  
Check if the dial tone stops.  
3) Press all extension numbers.  
Verify the ring back tone.  
4) Once the recipient answers the call, check the call status.  
5) Hang up the phone and call a busy station.  
Verify the busy tone.  
8.4.2 Station Camp-On Function  
If a caller dials a number and the recipient is busy, this function automatically connects the  
recipient and the caller right after the recipient hangs up the call.  
Follow the procedure below and check the Station Camp-On function:  
1) Lift the handset of the test phone and dial a busy station.  
Verify the busy tone.  
2) Upon verifying the busy tone, press the hook flash button.  
Check if the busy tone stops.  
3) Press the reservation code.  
Verify the confirmation tone.  
4) Lift the handset of the test phone and dial a busy station.  
Check if the test phone rings.  
5) Lift the handset of the test phone.  
Check if the ring stops and confirm the ring-back tone.  
Check if the other phone rings.  
6) Lift the handset of the other phone.  
Check if the other phone stops to ring, if the ring-back tone of the test phone stops,  
and if the parties are normally connected.  
© SAMSUNG Electronics Co., Ltd.  
8-5  
CHAPTER 8. Ошибка! Стиль не определен.  
8.4.3 C.O. Line Call Function  
Follow the procedure below and check if outside calls are normally connected.  
1) Lift the handset of the test phone.  
Verify the intercom dial tone.  
2) Press the C.O. line call code.  
Verify the C.O. line dial tone.  
3) Check if an error tone is activated for phones that do not support C.O. line calls.  
4) Press an external number.  
Verify the ring back tone.  
5) Once the call is connected, check the call status.  
8.4.4 C.O. Line Camp-On Function  
If a caller presses a C.O. line code to make an outside call and all C.O. lines are busy, this  
function reserves a C.O. line and notifies the caller if the C.O. line becomes available.  
Follow the procedure below and check the C.O. Line Camp-On function.  
1) Lift the handset of the test phone and press a C.O. line code.  
Verify the C.O. line dial tone.  
2) Check if a busy tone rings when all C.O. lines are busy.  
3) Upon verifying the busy tone, press the hook flash switch of the test phone.  
Check if the busy tone stops.  
4) Press the code number of the C.O. line Camp-On function.  
Verify the confirmation tone.  
5) Replace the handset of the test phone and make the C.O. line idle.  
Check if the test phone rings and if the C.O. line becomes busy.  
6) Lift the handset of the test phone.  
Check if the test phone stops to ring and verify the intercom dial tone and the C.O. line  
dial tone.  
8-6  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100 Installation Manual  
ABBREVIATION  
4
4SWM  
4TRM  
4DLM  
4SLM  
4 port Switch Module  
4 port Trunk Module  
4 port DLI Module  
4 port SLI Module  
A
AC  
Alternating Current  
Automatic Function Test  
Add On Module  
AFT  
AOM  
AP  
Access Point  
AWG  
American Wire Gauge  
C
D
CTI  
Computer Telephony Integration  
DC  
Direct Current  
DLI  
Digital Line Interface  
Door Phone Interface Module  
Digital Subscriber Line  
DPIM  
DSL  
G
H
I
GND  
HYB  
IP  
Ground  
Hybrid  
Internet Protocol  
© SAMSUNG Electronics Co., Ltd.  
I
Ошибка! Стиль не определен.  
K
KDB  
Keyset Daughter Board  
L
LAN  
LCD  
LED  
LIM  
Local Area Network  
Liquid Crystal Display  
Light Emitting Diode  
LAN Interface Module  
PLIM  
LAN Interface Module with PoE feature  
M
MP10  
MP11  
MGI16  
MGI64  
MMC  
MIS  
Main Control Processor for OfficeServ 7100  
Main Control Processor with Router for OfficeServ 7100  
16Channel Media Gateway Interface  
64Channel Media Gateway Interface  
Man Machine Command  
Miscellaneous  
P
PC  
Personal Computer  
Pulse Code Modulation  
Primary Rate Interface  
Power Supply Unit  
PCM  
PRI  
PSU  
S
SLI  
Single Line Interface  
SMDR  
Station Message Detail Recording  
T
TEPRI2  
TRK  
T1E1PRI  
Trunk  
UTP  
Unshielded Twisted Pair  
W
WAN  
WBS  
WIM  
WIMD  
WIP  
Wide Area Network  
Wireless Base Station  
Wide Area Network Interface Module  
WAN Interface Module Daughter board  
Wireless Local Area Network IP  
Wireless Local Area Network Interface  
WLI  
II  
© SAMSUNG Electronics Co., Ltd.  
OfficeServ 7100  
Installation Manual  
©2006 Samsung Electronics Co., Ltd.  
All rights reserved.  
Information in this manual is proprietary to SAMSUNG  
Electronics Co., Ltd.  
No information contained here may be copied, translated,  
transcribed or duplicated by any form without the prior written  
consent of SAMSUNG.  
Information in this manual is subject to change without notice.  