| PrecisionCell II M and MSH   Extended Surface Mini Pleat Filters   in "C" Channel Metal Frame   Extended Surface Mini Pleat Filters   in Metal Frame with Single 13/16" Header   Bulletin PB1006-1106   PrecisionCell II 4 inch deep in M and MSH designs   are designed to be operated at 500 FPM. Both M   and MSH Model PrecisionCell II's are offered in all   standard sizes. Special sizes are not available.   All PrecisionCell II models utilize state of the art   minipleat technology which uses media separators   made from thermoplastic glue beads to allow preci-   sion spacing between the moisture-resistant   microfine fiberglass media. The adjacent polymer   bead separators cure into durable, hard strips sep-   arating the media folds thereby creating a rigid   pack assembly which maintains excellent pleat   spacing continuity over the life of the filter.   Both PrecisionCell II metal-framed models are   bonded and sealed into a corrosion-resistant, metal   frame with an expanded metal face grille on the   downstream side to prevent media pack oscillation   or blowout. Both metal framed models are the ideal   choice where HVAC Systems pull in 100% humid   outside air such as Hospitals.   General:   PrecisionCell II extended surface minipleat filters   now offer the end user high efficiency filtration per-   formance in minimal media pack depths of 4 inch-   es deep in 60-65% (MERV 11), 80-85% (MERV   13), and 90-95% (MERV 14-15), and are available   in a corrosion resistant metal frame (M) for box   style or optional metal frame with a single 13/16"   header (MSH).   Due to the rigid minipleat technology in combina-   tion with the metal frame design, PrecisionCell II's   are the ideal choice for use in existing and new   installations where space is limited or where   upgrading filter efficiency levels are required in   existing units. Variable air volume systems, turbu-   lent airflow, or high humidity applications where   conventional filters fail, are good choices for   upgrading to PrecisionCell II's in metal frame con-   figurations.   Important Features   • High Efficiency Filtration in minimal, space-saving   design.   • This unique shallow-depth pack compacts up to 2   times the media area found in conventional 12   inch deep filters.   • 3-to-1 ratio in shipping, storage, handling and dis-   posal costs over conventional 12" deep cells   • Excellent choice for upgrading older systems at a   fraction of the cost.   Flanders PrecisionAire - Foremost in Air Filtration   Toll Free: 1-800-637-2803   1 Standard Box Style   Nominal Size   WxHxD (inches)   Nominal   Capacity (CFM)   Pressure Drop   80-85%   Approx. Media   Area (Sq. Ft.)   90-95%   60-65%   12x24x4   16x20x4   16x25x4   18x24x4   20x20x4   20x24x4   20x25x4   24x24x4   1000   1111   1389   1500   1388   1666   1736   2000   .75   .75   .75   .75   .75   .75   .75   .75   .70   .70   .70   .70   .70   .70   .70   .70   .55   .55   .55   .55   .55   .55   .55   .55   58   64   80   86   80   96   100   115   With Header   Nominal Size   WxHxD (inches)   Nominal   Capacity (CFM)   Pressure Drop   80-85%   Approx. Media   Area (Sq. Ft.)   90-95%   60-65%   12x24x4   16x20x4   16x25x4   18x24x4   20x20x4   20x24x4   20x25x4   24x24x4   1000   1111   1389   1500   1388   1666   1736   2000   .85   .85   .75   .75   .75   .75   .75   .75   .80   .80   .70   .70   .70   .70   .70   .70   .65   .65   .55   .55   .55   .55   .55   .55   48   53   66   71   66   79   82   95   Notes   1. PD represents clean pressure drop in inches w.g. Recommended final pressure drop for all models   is 1.5 inch w.g.   2. Actual filter face size of 24” x 24” and 24” x 12” is 5/8” undercut on height and width. All other sizes   are 1/2” undercut on height and width. Actual filter depth is 3-3/4”   3. Efficiency is average and is based on ASHRAE Standard 52.1 and 52.2 test methods.   4. Performance tolerances conform to Section 7.4 of ARI Standard 850.   5. Perfmormance values shown in this publication may be averages or estimates intended to generally represent product   styles. Always contact factory for latest actual test data on specific Flanders Precisionaire models.   Prefilters   VAV Systems   Prefilters are always a wise choice for the protec-   tion of minipleat filters no matter what the efficiency   or brand. The closely-spaced pleats are subject to   face-loading (bridging) by lint and coarse particles,   thus reducing their usual long life. A minimum 25-   30% ASHRAE efficiency pleated panel filter such   as the Flanders Precisionaire Prepleat 40 is recom-   mended.   Filter banks should be sized so that the face veloc-   ity at maximum design conditions is 625 fpm or   less. PrecisionCell II filters may be applied at any   capacity between 0 and 625 fpm. Operating a filter   bank at reduced flow will greatly increase expected   filter life.   Save Storage Space and Shipping Costs   Using the 24” x 24” size as an example, a carton of   four PrecisionCell II 4” filters has a volume of 5.3   cubic feet and a weight of 26 lbs. Compare this to   four 12” deep rigid separator-type filters packed in   four cartons with a total volume of 16 cubic feet and   total weight of 80 lbs.   Save In-Line Space   Compare the airway lengths of 22” PrecisionPak   bag filters and 12” Rigid-Air filter to a 4”   PrecisionCell filter when they are installed with 2”   prefilters.   Flanders PrecisionAire - Foremost in Air Filtration   Toll Free: 1-800-637-2803   3 Application Guidelines   PrecisionCell II filters should be selected for   new installations with 24” H x 24” W and 24”   H x 12” W face sizes. These are the most   widely used and stocked sizes. This allows   for 12” increments in height and width of the   filter bank and insures that replacement car-   tridges will be readily available.   PrecisionCell II filters should be installed with   the pleats vertical wherever possible. It is   permissible to install 24” H x 12” W face size   filters with pleats horizontal if necessary to   meet the size requirements of the filter bank.   PrecisionCell II M and MSH   Component Chart   88655. 04 20 24 MSH D   Efficiency Series   Frame Style   MSH - Metal   w-13/16”   89655. - 90-95%   88655. - 80-85%   86655. - 60-65%   Single Header   Nominal Depth   04 - 3.75” Deep   Gasket Location   D - Downstream   U - Upstream   Nominal Width   20 - (19-3/8”) wide   HEPA Prefilters   Nominal Height   V - One Vertical Side   PrecisionCell II filters are ideal as prefilters   for Alpha Cell HEPA filters. Their light weight   and 4” depth make them an excellent choice   24 - (23-3/8”) tall   for installation in the optional Prefilter Frame Assembly for the Alpha Cell HEPA Filter Holding Frame or in   Surelock Side Access HEPA Housings.   Specify the Surelock housing with an optional 4” wide prefilter track for the PrecisionCell II filters, in lieu of   the 2” wide prefilter track for pleated panel filters. We recommend the selection of 80-85% PrecisionCell II   filters as HEPA prefilters.   Guide Specifications   1.0 General   2.3 The filter pack shall be enclosed and sealed with-   in a corrosion-resistant metal frame.   1.1 Medium and high efficiency extended surface   filters shall be PrecisionCell II (M) (MHS) mini-   pleat panel filters as manufactured by Flanders   Precisionaire.   2.4 PrecisionCell II MSH filters shall have a single   13/16” diameter header on the air entering side.   3.0 Performance   1.2 Filter sizes, efficiencies and capacities shall be   3.1 Initial and final resistances shall not exceed the   scheduled values.   as scheduled on the drawings.   1.3 Filters shall be UL 900 Class 2 listed.   3.2 Media area must equal or exceed that of the   specified filter   2.0 Filter Construction   3.3 The average efficiency shall be as determined   by ASHRAE Standard 52.1 and 52.2 test   methods.   3.4 The manufacturer shall guarantee performance   as stated in the literature within tolerances as   outlined in Section 7.4 of ARI Standard 850.   2.1 The filter pack shall be constructed of water-laid   microfine fiberglass media containing a water   repellent binder formed into closely spaced pleats   held in position by adhesive bead separators.   REPRESENTED BY:   Flanders PrecisionAire   Foremost in Air Filtration   Toll Free 1-800-637-2803   4 |