LG LW1019IVSM User Manual

OWNER’S MANUAL  
AIR CONDITIONER  
Read this owner’s manual thoroughly before operating the  
appliance and keep it handy for reference at all times.  
TYPE : WINDOW (INVERTER)  
EN ENGLISH  
LW1019IVSM  
*MFL71143116*  
Copyright © 2020 LG Electronics Inc. All Rights Reserved.  
MFL71143116  
Rev.02_100820  
SAFETY INSTRUCTIONS  
3
EN  
SAFETY INSTRUCTIONS  
READ ALL INSTRUCTIONS BEFORE USE  
Your safety and the safety of others are very important.  
We have provided many important safety messages in this manual and on your appliance. Always  
read and follow all safety messages.  
This is the safety alert symbol.  
This symbol alerts you to potential hazards that can kill or injure you and others.  
All safety messages will follow the safety alert symbol and either the word WARNING or  
CAUTION.  
These words mean:  
WARNING  
You may be killed or seriously injured if you do not follow instructions.  
CAUTION  
You may be injured or cause damage to the product if you do not follow instructions.  
All safety messages will tell you what the potential hazard is, tell you how to reduce  
the chance of injury, and tell you what may happen if the instructions are not followed.  
The following symbols are displayed on units.  
This symbol indicates that this appliance uses a flammable refrigerant. If the refrigerant is  
is leaked and exposure to an external ignition source, there is a risk of fire.  
This symbol indicates that the Operation Manual should be read carefully.  
This symbol indicates that a service personnel should be handling this equipment with  
reference to the Installation Manual.  
This symbol indicates that information is available such as the Operating Manual or  
Installation Manual.  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING  
injury to persons when using this product, follow basic precautions,  
including the following:  
INSTALLATION  
Before use, the appliance must be properly installed as described in this manual.  
Contact the authorized service technician for repair or maintenance of this unit.  
Contact the installer for installation of this unit.  
The air conditioner is not intended for use by young children or invalids without supervision.  
Young children should be supervised to ensure that they do not play with the air conditioner.  
4
SAFETY INSTRUCTIONS  
When the power cord is to be replaced, replacement work shall be performed by authorized  
personnel only using only genuine replacement parts.  
Installation work must be performed in accordance with the National Electric Code by qualified  
and authorized personnel only.  
Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.  
Always plug into a grounded outlet.  
Do not under any circumstances, cut or remove the third (ground) prong from the power cord.  
When installing or moving the appliance, be careful not to pinch, crush, or damage the power  
cord.  
Plug in the power plug properly.  
Do not modify or extend the power cord.  
Do not start/stop operation by plugging/unplugging the power cord.  
If the cord/plug is damaged, have it replaced by an authorized service person using authorized  
replacement parts.  
Use a dedicated circuit.  
Do not disassemble or modify the product.  
Adhere to all industry recommended safety procedures including the use of long-sleeved gloves  
and safety glasses.  
Use care when unpacking and installing. The edges of the product may be sharp.  
Disconnect the power cord or circuit breaker before installing or servicing the appliance.  
Keep packaging materials out of the reach of children. These materials can pose a suffocation  
risk to children.  
Store and install the product where it will not be exposed to temperatures below freezing or  
exposed to outdoor weather conditions.  
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any  
other appliance.  
OPERATION  
Use this appliance only for its intended purpose.  
Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled,  
or has missing or broken parts, including a damaged cord or plug.  
Repair or immediately replace all power cords that have become frayed or otherwise damaged.  
Do not use a cord that shows cracks or abrasion damage along its length or at either end.  
Do not run cord under carpets or mats where it could be stepped on and damaged.  
Keep the cord out from under heavy objects like tables or chairs.  
Do not place the power cord near a heat source.  
Do not use an adaptor or plug the product into a shared outlet.  
Do not tamper with controls.  
If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance,  
unplug it immediately, and contact an LG Electronics Customer Information Center.  
Never unplug the appliance by pulling on the power cord. Always grip the plug firmly and pull  
straight out from the outlet.  
Do not grasp the power cord or touch the appliance controls with wet hands.  
SAFETY INSTRUCTIONS  
5
EN  
If water enters the product, turn off the power at the main circuit, then unplug the product and call  
for service.  
If the product has been submerged, contact an LG Electronics Customer Information Center for  
instructions before resuming use.  
Unplug the product when unused for long periods.  
Unplug the product before cleaning.  
In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a  
window or door to ventilate the area immediately.  
This appliance is not intended for use by persons (including children) with reduced physical,  
sensory or mental capabilities, or lack of experience and knowledge, unless they have been  
given supervision or instruction concerning the use of the appliance by a person responsible for  
their safety.  
The interior of the product must only be cleaned by an authorized service center or a dealer.  
Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,  
GROUNDING INSTRUCTIONS  
The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with  
a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The  
sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND)  
PRONG FROM THE POWER PLUG.  
- Situations when the appliance will be disconnected occasionally; Because of potential safety  
hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an  
adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from  
most local hardware stores.  
The large slot in the adapter must be aligned with the large slot in the receptacle to assure a  
proper polarity connection.  
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the  
appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded  
to make sure the receptacle is properly grounded.  
Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter  
ground terminal might break. Do not use the appliance with a broken adapter plug.  
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these  
situations. Unplugging the power cord frequently can lead to an eventual breakage of the  
ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet  
instead.  
6
SAFETY INSTRUCTIONS  
CAUTION  
To reduce the risk of minor or moderate injury to persons, malfunction, or  
damage to the product or property when using this product, follow basic  
precautions, including the following:  
INSTALLATION  
Take care when installing the product that exhaust or condensation does not damage nearby  
property.  
Follow installation instructions exactly to avoid excessive vibration or water leakage.  
OPERATION  
This appliance is not intended for use as a precision refrigeration system. Do not use it for special  
purposes such as maintaining pets, food, precision machinery, or art objects.  
When installing or moving the appliance, be careful not to pinch, crush, or damage the power  
cord.  
Make sure the air inlet and outlet are free from obstructions.  
Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.  
Do not step on or place heavy objects on top of the appliance.  
Do not drink water drained from the appliance.  
are used simultaneously.  
Do not expose people, animals, or plants to the cold or hot wind from the air conditioner for  
extended periods of time.  
Remove the batteries if the remote control is not to be used for an extended period of time.  
Never mix different types of batteries, or old and new batteries for the remote control.  
f with clean water.  
consult a doctor.  
Do not recharge or disassemble the batteries.  
MAINTENANCE  
Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water.  
Use a smooth cloth.  
SAFETY INSTRUCTIONS  
7
EN  
REFRIGERANT (FOR R32 ONLY)  
WARNING  
Do not use means to accelerate the defrosting process or to clean, other than those  
recommended by the manufacturer.  
The appliance shall be stored in a room without continuously operating ignition sources (for  
CAUTION  
associated with older units. Please follow all precautions and advisories.  
- Use caution while handling and prevent damage to unit. Do not put any holes into product for  
any reason. This can cause damage to product and prevent unit from cooling.  
- Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly  
clean unit can result in damage to the refrigeration system and or the electrical system.  
- Make certain that all the air circulation/ventilation openings are free from obstruction.  
-
warranties.  
-
water heaters or furnaces. Also keep away from electric heaters. Damaged units should be  
repaired before storage.  
SAVE THESE INSTRUCTIONS  
8
PRODUCT OVERVIEW  
PRODUCT OVERVIEW  
Exterior Parts  
Interior Parts  
9
3
1
2
1
4
5
8
7
6
7
6
5
4
3
2
Control Panel  
Remote Control  
Air Filter  
Evaporator  
Air Guide  
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
Control Box  
Condenser  
Compressor  
Base Pan  
Air Inlet  
Front Grille  
Cabinet  
Power Cord  
Air Outlet  
INSTALLATION  
9
EN  
INSTALLATION  
WARNING  
Electrical Data  
This appliance should be installed in  
accordance with the National Electrical  
Code.  
Power cord may include a current interrupter  
device. TEST and RESET buttons are provided  
on the plug case. The device should be tested on  
TEST button  
Use of extension cords could cause serious  
injury or death.  
and then the RESET button. If the TEST button  
does not trip or if the RESET button will not stay  
engaged, discontinue use of the air conditioner  
- Do not use an extension cord with this  
window air conditioner.  
- Do not use surge protectors or multi-outlet  
adapters with this window air conditioner.  
Never push the TEST button during  
operation. Doing so can damage the plug.  
for 120 V  
- Do not remove, modify, or immerse this  
plug. If this device trips, the cause should  
be corrected before further use.  
CAUTION  
Use Wall Receptacle  
Power Supply  
The conductors inside this cord are  
surrounded by shields, which monitor  
leakage current. These shields are not  
grounded. Periodically examine the cord  
for any damage. Do not use this product  
in the event the shields become exposed.  
Avoid shock hazard. This unit cannot be  
user-serviced. Do not open the tamper-  
resistant sealed portion. All warranties and  
performance will be voided. This unit is not  
intended to be used as an ON/OFF switch.  
Use 15 A, time  
delay fuse or 15 A,  
circuit breaker.  
Standard 120 V, 3-wire  
grounding receptacle rated  
15 A / 120 VAC / 60 Hz  
10 INSTALLATION  
Parts Included (Appearance May Vary)  
Heatproof foam (2)  
(Adhesive backed)  
Foam-PE (2)  
(Adhesive backed)  
Foam strip  
(Non-adhesive)  
Right curtain  
panel  
L bracket (3)  
Left curtain  
panel  
Support bracket  
Type 'A' Screws  
(11)  
Type 'B' Screws  
(5)  
Tools Needed  
Phillips-head  
screwdriver  
Adjustable wrench  
Level  
Gloves  
Tape measure  
Scissors or  
Pencil  
Cutting knife  
INSTALLATION 11 EN  
NOTE  
How to Install the Unit  
All supporting parts should be secured to firm  
wood, masonry, vinyl, fiberglass, or metal  
To prevent vibration and noise, make sure  
the unit is installed securely and firmly.  
1
This product is a window air conditioner.  
As such, a standard single-hung or double-hung  
window is required for proper installation.  
Non-window installations, including using sleeves  
or wall openings, and other installation methods  
are not recommended.  
Install the unit out of direct sunlight.  
2
3
There should be no obstacles, such as a  
fence or wall, within 20" from the back of the  
cabinet because it will prevent heat radiation  
of the condenser.  
Restriction of outside air will greatly reduce  
the cooling efficiency of the air conditioner.  
Storm Window Requirements  
Fence  
Awning  
Windows that include a storm window frame  
1
Cooled air  
Heat  
may prevent the air conditioner from tilting  
down toward the outside to drain properly.  
For proper drainage, attach a 1" x 2" piece  
of wood to the inner sill, trimmed to a length  
which fits inside the window frame. The top  
of the wood shim must be at least 3/4"  
higher than the top of the storm window  
frame. Attach the wood securely to the sill  
with nails or screws.  
radiation  
About 1/4"  
CAUTION  
If necessary, attach another 1" x 2" wood  
2
DO NOT cover or block any of the side and  
top louvers. All side louvers of the cabinet  
must remain exposed to the outside  
of the structure and unobstructed.  
strip flush against the back of the inner sill.  
This will raise the L bracket, as shown in the  
drawing.  
Install the unit slightly tilted so the back is  
slightly lower than the front (about 1/4").  
This will force condensed water to flow to  
the outside.  
4
5
Wood Strip Mounted  
on Top of Inner Sill  
3/4" higher than  
storm window frame  
L Bracket  
Inner Sill  
Storm  
Install the unit with the bottom between  
30" ~60" above the floor level.  
Window Frame  
Wood Strip for  
L bracket  
Outer Sill  
Nail or screw  
Indoors  
Window Requirements  
Outdoors  
This unit is designed for installation in standard  
double hung windows with actual opening  
widths from 22" to 36".  
The top and bottom window sashes must open  
13" from the bottom of the upper sash to the  
inside sill.  
22" to 36"  
13" min  
12 INSTALLATION  
Install the L bracket behind the inner  
window sill as shown.  
4
Preparation of Chassis  
Insert the top and bottom rails of the  
curtain panels into the upper and lower  
panel guides.  
Use the 2 type A screws provided.  
1
Fasten the curtain panels to the unit with 8  
type A screws.  
Fasten screws behind the curtain panel.  
Inner Sill  
Screws  
(Type A)  
Outer Sill  
Center Line  
Left Curtain  
Panel  
Right  
L Bracket  
Curtain  
Panel  
Screws  
(Type A)  
NOTE  
The bracket helps to hold unit securely in  
place. Be sure to place bracket edge flush  
against back of inner sill.  
Screws  
(Type A)  
Bottom Guide  
NOTE  
Unit Installation  
CAUTION  
Use a long screwdriver to make installing  
the screws easier.  
Cut the window sash seals to the proper  
2
During the following step, hold unit firmly until  
window sash is lowered to top channel behind  
side panel frames. Personal injury or property  
damage may result if unit falls from window.  
length. Peel off the backing and attach the  
adhesive-backed foam to the underside  
of the window sash and bottom of window  
frame.  
Set the air conditioner in the window so that  
is centered. Place the air conditioner so that  
front edge of the bottom guide is against the  
back edge of the sill.  
1
Bring the window down so that the front edge  
of the upper guide is in front of the window.  
Make sure that air conditioner is level or  
tilting slightly to the outside.  
Foam-PE  
(Adhesive backed)  
Open the window and draw a center line  
3
on the center of the inner sill.  
Then mark lines 8" to the left and right of  
the center line.  
Window Frame  
Upper Guide  
Seal  
About ¼"  
Bottom Guide  
Center Line  
Inner Sill  
Room Side  
8"  
8"  
L Bracket  
INSTALLATION 13 EN  
Remove the screw from the bottom right  
Extend the guide panels to fill the window  
opening and use 4 type B screws to secure  
them to the window.  
5
2
of the cabinet. Attach the support bracket  
using the screw you just removed.  
Secure the support bracket to the inner  
window sill using a type B screw.  
Screw  
(Type B)  
Screws  
(Type B)  
Cut the non-adhesive foam strip to the  
proper length and insert it between the  
upper window sash and the lower window  
3
sash.  
Support Bracket  
After the air conditioner is installed,  
measure the curtain panel on each side  
and cut the adhesive-backed heatproof  
foam to fit each panel. The size of the  
panels may differ. Remove the backing  
from the heatproof foam and attach the  
foam to the curtain panels.  
6
Foam Strip  
(Non-adhesive)  
To prevent broken glass or damage to  
windows, on vinyl or other similarly  
constructed windows, attach the L bracket  
with a type A screw.  
(Adhesive Backed)  
4
W1  
W2  
Vinyl  
Screw  
(Type A)  
W
W2  
H
W1  
L Bracket  
H
Wood  
H
Heatproof Foam  
NOTE  
Screw  
Heatproof foam improves the cooling  
capability of the air conditioner.  
(Type A)  
See the Electrical Data section for  
information on attaching the power cord  
to an electrical outlet.  
14 OPERATION  
OPERATION  
Control Panel and Remote Control  
Remote Control  
5
6
7
8
9
8
1
Auto Clean(3 s)  
4
3
7
Light Off(3 s)  
10  
2
4
3
2
1
NOTE  
The feature may be changed according to the type of model.  
Power  
Energy Saver - In this mode the  
1
2
compressor and fan turn off when the set  
temperature is achieved. Approximately  
every 3 minutes the fan turns on to allow  
the unit sensor to accurately determine if  
more cooling is needed.  
Press to turn the air conditioner ON or OFF.  
Sleep Mode  
This mode keeps operating noise to a  
minimum and turns the air conditioner off  
after a set time. The timer can be set from  
1 to 12 hours.  
In the Sleep Mode, the setting temperature  
increases by 2 °F after 30 minutes and  
additional 2 °F after another 30 minutes  
for a more comfortable sleep.  
Cool - This mode is ideal on hot days to  
cool and dehumidify the room quickly. Use  
the Temp  
buttons to set the desired  
room temperature and use the Fan Speed  
button to set the desired fan circulation  
speed.  
The setting temperature increases up to  
4 °F from the preset temperature.  
Fan Only - In this mode the fan circulates  
air but the compressor does not run. Use  
the Fan Speed button to set fan speed to  
High, Medium or Low. In this mode, you  
cannot adjust the set temperature.  
Delay ON/OFF Timer  
3
Delay ON - When the air conditioner is off,  
set it to automatically turn on from 1 to 24  
hours later, at its previous mode and fan  
settings.  
Dry - This mode is ideal for rainy and  
damp days to dehumidify the room rather  
Delay OFF - When the air conditioner is on,  
set it to automatically turn off from 1 to 24  
hours later.  
removed from the room by the combination  
of compressor operation and the fan speed  
off once the set temperature is reached.  
Fan speed cannot be adjusted in Dry mode.  
NOTE  
Each press of the Timer button advances  
the timer by 1 hour. After the last press  
the display returns to the temperature  
setting.  
Wi-Fi  
5
Enables connection of the air conditioner to  
the home Wi-Fi.  
Operation Mode  
4
Press the Mode button to cycle between  
4 types of air conditioner operation: Energy  
Saver / Cool / Fan Only / Dry.  
OPERATION 15 EN  
Clean Filter  
6
Using the Light Off Function  
The Clean Filter LED lights up to notify you  
You can set the brightness of the control panel,  
Temp  
and  
Press Mode button on the remote control for  
3 seconds, or  
together on the control panel to turn off the  
Clean Filter light.  
Press Mode and Sleep button together on  
the control panel.  
NOTE  
NOTE  
control panel, not the remote control.  
Turn on/off the control panel.  
This feature is a reminder to clean the air  
light turns on after 250 hours of operation.  
Using the Auto Clean Function  
Fan Speed  
7
8
In the Cooling and Dry Mode, Moisture is  
generated inside the indoor unit. This function  
removes such moisture.  
Press to set the fan speed to Low (F1),  
Medium (F2), or High (F3).  
Temperature Control  
Energy Saver  
Press  
control for 3 seconds.  
is displayed on the remote control.  
button on the remote  
The thermostat monitors room temperature  
to maintain the desired temperature. The  
thermostat can be set between 60 °F–86 °F  
(16 °C–30 °C). Press  
increase or decrease temperature setting.  
or  
arrows to  
NOTE  
If you turn off the unit, the fan continues to run  
for 10 minutes and cleans the inside of the  
indoor unit.  
Energy Saver  
9
In this mode the compressor and fan turn  
off when the set temperature is achieved.  
Approximately every 3 minutes the fan turns  
on to allow the unit sensor to accurately  
determine if more cooling is needed.  
Clear  
10  
Cancel Sleep and Timer settings.  
NOTE  
Auto Restart: If the air conditioner turns off due  
to a power outage, it will restart automatically  
once the power is restored, with the same  
settings as were set before the unit turned off.  
Energy Saver: The unit defaults to the Energy  
Saver mode each time the unit is switched on  
except in Fan mode or when power is restored  
after an electrical power outage.  
The remote control will not function properly if  
the AC infrared sensor is exposed to direct light  
or if there are obstacles between the remote  
controller and the air conditioner.  
16 OPERATION  
Air Direction  
Wireless Remote Control  
Inserting Batteries  
of the air conditioner’s louvers.  
If the display screen of the remote control begins  
to fade, replace the batteries. Insert AAA (1.5 V)  
batteries before using the remote control.  
Direction  
Remove the cover on the back of the  
remote control.  
1
levers of the vertical louvers to the left or right.  
With the plus and minus poles facing as  
marked, insert two new AAA 1.5V batteries  
2
Direction  
up or down.  
NOTE  
Two new batteries are supplied with the air  
conditioner for use in the remote control.  
Do not use a rechargeable battery. Make sure  
that the battery is new.  
In order to prevent discharge, remove the  
battery from the remote control if the air  
conditioner is not going to be used for an  
extended period of time.  
NOTE  
When the weather is extremely hot, the unit  
may turn off automatically to protect the  
compressor.  
Keep the remote control away from extremely  
hot or humid places.  
To maintain optimal operation of the remote  
control, the remote sensor should not be  
exposed to direct sunlight.  
Additional Features  
Slinger Fan  
This air conditioner is equipped with a slinger  
fan. (See drawing.)  
The fan’s outer ring picks up the condensed  
water from the base pan if the water level gets  
high enough. The water is then picked up by the  
fan and expelled through the condenser, making  
Ring  
SMART FUNCTIONS 17 EN  
Connect your smartphone to the wireless  
router.  
3
SMART FUNCTIONS  
LG ThinQ Application  
This feature is only available on models with  
the  
or ThinQ logo  
The LG ThinQ application allows you to  
communicate with the appliance using a  
smartphone.  
NOTE  
To verify the Wi-Fi connection, check that  
LG ThinQ Application Features  
icon on the control panel is lit.  
The appliance supports 2.4 GHz Wi-Fi  
networks only. To check your network  
frequency, contact your Internet service  
provider or refer to your wireless router  
manual.  
Communicate with the appliance from a  
smartphone using the convenient smart features.  
Smart DiagnosisTM  
If you experience a problem while using the  
appliance,this smart diagnosis feature will help  
you diagnose the problem.  
LG ThinQ is not responsible for any network  
connection problems or any faults,  
malfunctions, or errors caused by network  
connection.  
Settings  
If the appliance is having trouble connecting to  
the Wi-Fi network, it may be too far from the  
router. Purchase a Wi-Fi repeater (range  
Allows you to set various options on the  
appliance and in the application.  
extender) to improve the Wi-Fi signal strength.  
The Wi-Fi connection may not connect or may  
be interrupted because of the home network  
environment.  
NOTE  
If you change your wireless router, internet  
service provider, or password, delete the  
registered appliance from the LG ThinQ  
application and register it again.  
The network connection may not work  
properly depending on the Internet service  
provider.  
The application is subject to change for  
appliance improvement purposes without  
notice to users.  
The surrounding wireless environment can  
make the wireless network service run slowly.  
The appliance cannot be registered due to  
problems with the wireless signal  
Functions may vary by model.  
transmission. Unplug the appliance and wait  
about a minute before trying again.  
Before Using LG ThinQ Application  
If the firewall on your wireless router is  
enabled, disable the firewall or add an  
exception to it.  
Check the distance between the appliance  
and the wireless router (Wi-Fi network).  
1
If the distance between the appliance and  
the wireless router is too far, the signal  
strength becomes weak. It may take a  
long time to register or installation may  
fail.  
The wireless network name (SSID) should be  
a combination of English letters and numbers.  
(Do not use special characters.)  
Smartphone user interface (UI) may vary  
depending on the mobile operating system  
(OS) and the manufacturer.  
Turn off the Mobile data or Cellular Data  
on your smartphone.  
2
If the security protocol of the router is set to  
WEP, you may fail to set up the network.  
Please change it to other security protocols  
(WPA2 is recommended) and register the  
product again.  
18 SMART FUNCTIONS  
Using LG ThinQ to Diagnose  
Issues  
Installing the LG ThinQ  
Application  
Search for the LG ThinQ application from  
the Google Play Store or Apple App Store on a  
smartphone. Follow instructions to download  
and install the application.  
If you experience a problem with your Wi-Fi  
equipped appliance, it can transmit troubleshooting  
data to a smartphone using the LG ThinQ  
application.  
Launch the LG ThinQ application and select  
the Smart DiagnosisTM feature in the menu.  
Follow the instructions provided in the LG  
ThinQ application.  
Open Source Software Notice  
Information  
To obtain the source code under GPL, LGPL, MPL,  
and other open source licenses, that is contained  
com.  
Using Audible Diagnosis to  
Diagnose Issues  
In addition to the source code, all referred license  
terms, warranty disclaimers and copyright notices  
are available for download.  
Follow the instructions below to use the audible  
diagnosis method.  
LG Electronics will also provide open source code  
to you on CD-ROM for a charge covering the cost  
of performing such distribution (such as the cost of  
media, shipping, and handling) upon email request  
to [email protected]. This offer is valid for a  
period of three years after our last shipment of this  
product. This offer is valid to anyone in receipt of  
this information.  
Launch the LG ThinQ application and select the  
Smart DiagnosisTM feature in the menu. Follow  
the instructions for audible diagnosis provided in  
the LG ThinQ application.  
Plug the power plug in the outlet properly.  
1
2
Place the mouthpiece of your smartphone close  
to the  
or  
logo.  
Smart DiagnosisTM  
Press and hold the DIAGNOSIS [5 s] button for  
5 seconds or longer while holding the smartphone  
mouthpiece to the logo until the data transfer is  
complete.  
3
This feature is only available on models with the  
or  
logo.  
Use this feature to help you diagnose and solve  
problems with your appliance.  
Keep the smartphone in place until the data  
transfer has finished. Time remaining for data  
transfer is displayed.  
NOTE  
For reasons not attributable to LGE’s  
After the data transfer is complete, the diagnosis  
will be displayed in the application.  
4
negligence, the service may not operate due to  
external factors such as, but not limited to, Wi-Fi  
unavailability, Wi-Fi disconnection, local app  
store policy, or app unavailability.  
NOTE  
For best results, do not move the phone while the  
tones are being transmitted.  
The feature may be subject to change without  
prior notice and may have a different form  
depending on where you are located.  
Be sure to keep ambient noise to a minimum or  
the phone may not correctly receive the buzzer  
beeps from the indoor unit.  
SMART FUNCTIONS  
19 EN  
FCC Notice  
FCC RF Radiation Exposure  
Statement  
This equipment complies with FCC radiation  
exposure limits set forth for an uncontrolled  
environment. This transmitter must not be co-  
located or operating in conjunction with any other  
antenna or transmitter.  
This following notice cover the transmitter  
module contained in this product.  
This equipment has been tested and found  
to comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference in a  
residential installation. This equipment generates,  
uses, and can radiate radio frequency energy  
and, if not installed and used in accordance with  
the instructions, may cause harmful interference  
to radio communications. However, there is no  
guarantee that interference will not occur in a  
particular installation. If this equipment does  
cause harmful interference to radio or television  
reception, which can be determined by turning  
the equipment off and on, the user is encouraged  
to try to correct the interference by one or more  
of the following measures:  
This equipment should be installed and operated  
with a minimum distance of 20 cm (7.8 inches)  
between the antenna and your body. Users must  
follow the specific operating instructions for  
satisfying RF exposure compliance.  
Wireless LAN Module Specifications  
Model  
LCW-010  
Frequency  
Range  
2412 to 2462 MHz  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and the receiver.  
Output  
Power  
(Max)  
< 30 dBm  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio/TV  
technician for help.  
This device complies with part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions:  
1) This device may not cause harmful  
interference and  
2) This device must accept any interference  
received, including interference that may  
cause undesired operation.  
Any changes or modifications in construction of  
this device which are not expressly approved by  
the party responsible for compliance could void  
the user’s authority to operate the equipment.  
20 MAINTENANCE  
2
3
MAINTENANCE  
40 °C (104 °F).  
WARNING  
Before cleaning or performing maintenance,  
disconnect the power supply and wait until  
the fan stops.  
Gently shake the excess water from the  
Air Filter  
Dry the filter in the shade.  
4
5
if cleaning is necessary. Trapped particles in the  
Insert the filter into the front grille.  
cooling capacity and causing an accumulation of  
frost on the evaporator.  
Cleaning the Air Conditioner  
Cleaning the Air Filter  
Wipe the front grille and inlet grille with a cloth  
dampened in a mild detergent solution.  
1
Wash the cabinet with mild soap or detergent  
and lukewarm water, then polish using liquid  
appliance wax.  
NOTE  
condenser coils (outside of unit) should be  
checked periodically and cleaned if clogged  
with soot or dirt from outside air.  
For repair and maintenance, contact an  
Authorized Service Center. See the warranty  
page for details or call 1-800-243-0000.  
Have your model number and serial number  
available. They can be found on the side of the  
cabinet. Record them on page 26 for future  
reference.  
TROUBLESHOOTING 21 EN  
TROUBLESHOOTING  
Before Calling for Service  
The appliance is equipped with an automatic error-monitoring system to detect and diagnose problems  
at an early stage. If the appliance does not function properly or does not function at all, check the  
following before you call for service.  
Normal Sounds You May Hear  
1
2
5
4
3
High Pitched Chatter  
1
2
3
Sound of Rushing Air  
At the front of the unit, you may hear the sound of rushing air being moved by the fan.  
Gurgle/Hiss  
Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during  
normal operation.  
Vibration  
4
5
Unit may vibrate and make noise because of poor wall or window construction or incorrect  
installation.  
Pinging or Swishing  
Droplets of water hitting condenser during normal operation may cause pinging or swishing  
sounds.  
22 TROUBLESHOOTING  
Problem  
Possible Cause  
Solutions  
Make sure the air conditioner plug  
is pushed completely into the outlet.  
The air conditioner is unplugged.  
Check the house fuse/circuit  
breaker box and replace the fuse or  
reset the breaker.  
The fuse is blown/circuit breaker  
is tripped.  
If power failure occurs, turn the  
mode control to off. When power is  
restored, wait 3 minutes to restart  
the air conditioner to prevent  
Air conditioner  
does not start.  
Power failure.  
tripping of the compressor overload.  
Press the RESET button located  
on the power cord plug. If the  
RESET button will not stay  
The current interrupter device is  
tripped.  
engaged, discontinue use of the air  
service technician.  
Make sure there are no curtains,  
blinds, or furniture blocking the front  
of the air conditioner.  
Set the desired temperature to  
a level lower than the current  
temperature.  
The temp control may not be set  
correctly.  
Air conditioner  
does not cool as it  
should.  
weeks. See the 'MAINTENANCE'  
section.  
The room may have been hot.  
turned on, you need to allow time  
for the room to cool down.  
Cold air is escaping.  
registers and cold air returns.  
See 'Air conditioner freezing up'  
below.  
Cooling coils have iced up.  
obstruct the air conditioner from  
properly cooling the room. Set the  
mode control at High Fan or High  
Cool.  
Air conditioner  
freezing up.  
The cooling coils are iced over.  
Hot, humid weather.  
Water drips  
outside.  
This is normal.  
TROUBLESHOOTING 23 EN  
Problem  
Possible Cause  
Solutions  
For proper water disposal, make  
The air conditioner is not tilted to sure the air conditioner slants  
Water drips  
indoors.  
the outside.  
slightly from the cabinet front to the  
rear.  
This is normal for a short period in  
areas with little humidity; normal for  
a longer period in very humid areas.  
Water collects in  
base pan.  
Moisture removed from air and  
drains into base pan.  
Air conditioner  
turns on and off  
rapidly.  
Outside temperature extremely  
hot.  
Refer to installation instructions or  
check with installer.  
This is normal. If too loud, set to  
lower FAN setting.  
Air movement sound.  
Noise when unit is  
cooling.  
Window vibration - poor  
installation.  
Refer to installation instructions or  
check with installer.  
Place remote control within 20 feet  
& 120° radius of the front of the  
unit.  
Remote control not located  
within range.  
Remote sensing  
deactivating  
prematurely.  
Remote control signal  
obstructed.  
Remove obstruction.  
Room too cold.  
Set temperature too low.  
Increase set temperature.  
Turn the air conditioner on.  
Turn the router on.  
Can't connect the  
LG ThinQ App. to  
the air conditioner.  
Air conditioner is turned off.  
Wireless router is turned off.  
Move the router closer to the air  
conditioner or purchase and install  
a Wi-Fi repeater (signal booster).  
The Wi-Fi router is too far from  
the air conditioner.  
The air conditioner  
is not connecting  
to the Wi-Fi.  
You do not have permission  
to use the router or it is  
incompatible.  
Make sure you are selecting the  
correct wireless router from the list.  
The router must be set to 2.4 GHz.  
NOTE  
If you see "CH" in the display, please call 1-800-243-0000.  
24 TROUBLESHOOTING  
Wi-Fi  
Problem  
Possible Cause  
Solutions  
Delete your home Wi-Fi network  
and begin the registration process  
again.  
The password for the Wi-Fi  
network was entered incorrectly.  
Turn off the Mobile data on your  
smartphone before registering the  
appliance.  
Mobile data for your smartphone  
is turned on.  
The wireless network name (SSID)  
should be a combination of English  
letters and numbers. (Do not use  
special characters.)  
The wireless network name  
(SSID) is set incorrectly.  
Trouble connecting  
appliance and  
Only a 2.4 GHz router frequency  
is supported. Set the wireless  
router to 2.4 GHz and connect the  
appliance to the wireless router. To  
check the router frequency, check  
with your Internet service provider  
or the router manufacturer.  
smartphone to  
Wi-Fi network.  
The router frequency is not 2.4  
GHz.  
If the appliance is too far from the  
router, the signal may be weak  
and the connection may not be  
The appliance is too far from  
the router.  
router closer to the appliance  
or purchase and install a Wi-Fi  
repeater.  
WARRANTY 25 EN  
WARRANTY  
ARBITRATION NOTICE: THIS LIMITED WARRANTY CONTAINS AN ARBITRATION PROVISION THAT  
REQUIRES YOU AND LG TO RESOLVE DISPUTES BY BINDING ARBITRATION INSTEAD OF IN  
COURT, UNLESS YOU CHOOSE TO OPT OUT. IN ARBITRATION, CLASS ACTIONS AND JURY  
TRIALS ARE NOT PERMITTED. PLEASE SEE THE SECTION TITLED “PROCEDURE FOR RESOLVING  
DISPUTES” BELOW.  
WHAT THIS WARRANTY COVERS:  
LG Electronics U.S.A., Inc. (“LG”) warrants your LG Room Air Conditioner ("product") against defect in  
materials or workmanship under normal household use, during the warranty period set forth below, LG  
will, at its option, repair or replace the product. This limited warranty is valid only to the original retail  
purchaser of the product, is not assignable or transferrable to any subsequent purchaser or user, and  
applies only when the product is purchased through an LG authorized dealer or distributor and used  
within the United States (“U.S.”) including U.S. Territories.  
NOTE  
Replacement products and repair parts may be new or factory-remanufactured and are warranted  
for the remaining portion of the original unit’s warranty period or ninety (90) days, whichever is  
longer. Please retain dated receipt or delivery ticket as evidence of the Date of Purchase for proof of  
warranty (you may be required to submit a copy to LG or authorized representative).  
WARRANTY PERIOD:  
1 year from the Date of Purchase: Any internal/ functional Parts and Labor  
HOW SERVICE IS HANDLED: In-Home Service  
In-home service will be provided during the warranty period subject to availability within the United  
States. In-home service may not be available in all areas. To receive in-home service, the product  
must be unobstructed and accessible to service personnel. If during in-home service repair cannot  
be completed, it may be necessary to remove, repair and return the product. If in-home service is  
unavailable, LG may elect, at our option, to provide for transportation of our choice to and from a LG  
authorized service center.  
THIS LIMITED WARRANTY DOES NOT COVER:  
Service trips to deliver, pick up, or install the product or for instruction on product use.  
Replacing house fuses or resetting of circuit breakers, correction of house wiring or plumbing, or  
correction of product installation.  
Damage or failure caused by leaky / broken / frozen water pipes, restricted drain lines, inadequate or  
interrupted water supply or inadequate supply of air.  
Damage or failure resulting from misuse, abuse, improper installation, repair or maintenance.  
Damage or failure caused by incorrect electrical current, voltage, or plumbing codes.  
unless such damage results from defects in materials or workmanship and is reported to LG within  
seven (7) calendar days from the date of delivery.  
Damage or missing items to any display, open box, discounted, or refurbished product.  
26 WARRANTY  
Product where the original factory serial numbers have been removed, defaced or changed in any  
way.  
Repairs when product is used in other than normal and usual household use (e.g. rental, commercial  
’s manual.  
The removal and reinstallation of the Product if it is installed in an inaccessible location.  
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING  
AND WITHOUT LIMITATION TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A  
PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW,  
THIS WARRANTY IS LIMITED IN DURATION TO THE TERM PERIOD EXPRESSED ABOVE.  
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE  
REMEDY FOR THE CUSTOMER. NEITHER THE MANUFACTURER NOR ITS U.S. DISTRIBUTOR  
SHALL BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR  
PUNITIVE DAMAGES OF ANY NATURE, INCLUDING AND WITHOUT LIMITATION TO, LOST  
REVENUES OR PROFITS, OR ANY OTHER DAMAGE, WHETHER BASED IN CONTRACT, TORT,  
OR OTHERWISE.  
Some states do not allow the exclusion or limitation of incidental or consequential damages or  
limitations on how long an implied warranty lasts, so the above exclusion or limitation may not apply  
state to state.  
HOW TO OBTAIN WARRANTY SERVICE & ADDITIONAL INFORMATION:  
Mail to: LG Customer Information Center (ATTN: CIC)  
201 James Record Road, Huntsville, AL 35824  
FOR YOUR RECORDS  
Write the model and serial numbers here:  
Model No.  
Serial No.  
This information is located on a label on the side of the unit.  
Dealer's Name  
Date Purchased  
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty  
issues.  
WARRANTY 27 EN  
PROCEDURE FOR RESOLVING DISPUTES:  
ALL DISPUTES BETWEEN YOU AND LG ARISING OUT OF OR RELATING IN ANY WAY TO THIS  
LIMITED WARRANTY OR THE PRODUCT SHALL BE RESOLVED EXCLUSIVELY THROUGH  
BINDING ARBITRATION, AND NOT IN A COURT OF GENERAL JURISDICTION. BINDING  
ARBITRATION MEANS THAT YOU AND LG ARE EACH WAIVING THE RIGHT TO A JURY TRIAL  
AND TO BRING OR PARTICIPATE IN A CLASS ACTION.  
Definitions. For the purposes of this section, references to “LG” mean LG Electronics U.S.A., Inc., its  
parents, subsidiaries and affiliates, and each of their officers, directors, employees, agents, beneficiaries,  
predecessors in interest, successors, assigns and suppliers; references to “dispute” or “claim” shall  
include any dispute, claim or controversy of any kind whatsoever (whether based in contract, tort, statute,  
regulation, ordinance, fraud, misrepresentation or any other legal or equitable theory) arising out of or  
relating in any way to the sale, condition or performance of the product or this Limited Warranty.  
Notice of Dispute. In the event you intend to commence an arbitration proceeding, you must first notify  
LG in writing at least 30 days in advance of initiating the arbitration by sending a letter to LG at LG  
Electronics, USA, Inc. Attn: Legal Department- Arbitration 111 Sylvan Avenue, Englewood Cliffs, NJ 07632.  
You and LG agree to engage in good faith discussions in an attempt to amicably resolve your claim.  
The notice must provide your name, address, and telephone number; identify the product that is the  
subject of the claim; and describe the nature of the claim and the relief being sought. If you and LG are  
unable to resolve the dispute within 30 days, either party may proceed to file a claim for arbitration.  
Agreement to Binding Arbitration and Class Action Waiver. Upon failure to resolve the dispute  
during the 30 day period after sending written notice to LG, you and LG agree to resolve any claims  
between us only by binding arbitration on an individual basis, unless you opt out as provided below.  
Any dispute between you and LG shall not be combined or consolidated with a dispute involving any  
other person’s or entity’s product or claim. More specifically, without limitation of the foregoing, any  
dispute between you and LG shall not under any circumstances proceed as part of a class or  
representative action. Instead of arbitration, either party may bring an individual action in small claims  
court, but that small claims court action may not be brought on a class or representative basis.  
Arbitration Rules and Procedures. To begin arbitration of a claim, either you or LG must make a written  
demand for arbitration. The arbitration will be administered by the American Arbitration Association  
(“AAA”) and will be conducted before a single arbitrator under the AAA’s Consumer Arbitration Rules  
that are in effect at the time the arbitration is initiated (referred to as the “AAA Rules”) and under the  
Send a copy of your written demand for arbitration, as well as a copy of this provision, to the AAA in  
the manner described in the AAA Rules. You must also send a copy of your written demand to LG at  
LG Electronics, USA, Inc. Attn: Legal Department- Arbitration 111 Sylvan Avenue, Englewood Cliffs,  
NJ 07632. If there is a conflict between the AAA Rules and the rules set forth in this section, the rules  
set forth in this section will govern. This arbitration provision is governed by the Federal Arbitration Act.  
Judgment may be entered on the arbitrator’s award in any court of competent jurisdiction. All issues are  
for the arbitrator to decide, except that issues relating to the scope and enforceability of the arbitration  
provision and to the arbitrability of the dispute are for the court to decide. The arbitrator is bound by the  
terms of this provision.  
Governing Law. The law of the state of your residence shall govern this Limited Warranty and any  
disputes between us except to the extent that such law is preempted by or inconsistent with applicable  
federal law.  
Fees/Costs. You do not need to pay any fee to begin an arbitration. Upon receipt of your written  
demand for arbitration, LG will promptly pay all arbitration filing fees to the AAA unless you seek more  
than $25,000 in damages, in which case the payment of these fees will be governed by the AAA Rules.  
Except as otherwise provided for herein, LG will pay all AAA filing, administration and arbitrator fees for  
any arbitration initiated in accordance with the AAA Rules and this arbitration provision. If you prevail in  
28 WARRANTY  
the arbitration, LG will pay your attorneys’ fees and expenses as long as they are reasonable, by  
considering factors including, but not limited to, the purchase amount and claim amount. Notwithstanding  
the foregoing, if applicable law allows for an award of reasonable attorneys’ fees and expenses, an  
arbitrator can award them to the same extent that a court would. If the arbitrator finds either the  
substance of your claim or the relief sought in the demand is frivolous or brought for an improper  
purpose (as measured by the standards set forth in Federal Rule of Civil Procedure 11(b)), then the  
payment of all arbitration fees will be governed by the AAA Rules. In such a situation, you agree to  
reimburse LG for all monies previously disbursed by it that are otherwise your obligation to pay under  
the AAA Rules. Except as otherwise provided for, LG waives any rights it may have to seek attorneys’  
fees and expenses from you if LG prevails in the arbitration.  
Hearings and Location. If your claim is for $25,000 or less, you may choose to have the arbitration  
conducted solely on the basis of (1) documents submitted to the arbitrator, (2) through a telephonic  
hearing, or (3) by an in-person hearing as established by the AAA Rules. If your claim exceeds $25,000,  
the right to a hearing will be determined by the AAA Rules. Any in-person arbitration hearings will be  
held at a location within the federal judicial district in which you reside unless we both agree to another  
location or we agree to a telephonic arbitration.  
Opt Out. You may opt out of this dispute resolution procedure. If you opt out, neither you nor LG can  
require the other to participate in an arbitration proceeding. To opt out, you must send notice to LG no  
later than 30 calendar days from the date of the first consumer purchaser’s purchase of the product by  
either: (i) sending an e-mail to [email protected], with the subject line: “Arbitration Opt Out” or (ii) calling  
1-800-980-2973. You must include in the opt out e-mail or provide by telephone: (a) your name and  
address; (b) the date on which the product was purchased; (c) the product model name or model  
number; and (d) the serial number (the serial number can be found (i) on the product; or (ii) online by  
“Find My Model & Serial Number”).  
You may only opt out of the dispute resolution procedure in the manner described above (that is, by  
e-mail or telephone); no other form of notice will be effective to opt out of this dispute resolution  
procedure. Opting out of this dispute resolution procedure will not affect the coverage of the Limited  
Warranty in any way, and you will continue to enjoy the full benefits of the Limited Warranty. If you keep  
this product and do not opt out, then you accept all terms and conditions of the arbitration provision  
described above.  
LG Customer Information Center  
1-800-243-0000  
Register your product Online!  
LG Electronics Inc.  
111 Sylvan Avenue, Englewood Cliffs, NJ 07632.  

York Sunline 2000 D3ce User Manual
Toshiba Air Conditioner Rav Sm404mut Tr User Manual
Sharp Air Purifier Replacement Filter Fzn40hfu User Manual
Sharp Af S85px User Manual
Schumacher Xc12 User Manual
Samsung Sh24ts6 User Manual
Samsung Aw149cb User Manual
LG LRG3060 User Manual
BLACK DECKER BDPG700 User Manual
ASUS TUF VG259QM User Manual