FURRION FACR14SA PS User Manual

Rooftop Air Conditioner  
Instruction Manual  
Model: FACR13SA-PS/FACR13SA-BL  
FACR14SA-PS/FACR14SA-BL  
FACR15SA-PS/FACR15SA-BL  
FACT11MA-PS/FACT11MA-BL  
(Sold Separately)  
Contents  
Welcome............................................................................................1  
Contents ............................................................................................2  
Important Safety Instructions............................................................3  
Handling the device.................................................................................................3  
Handling Electrical Cables .....................................................................................4  
Important Safety Instructions............................................................4  
Before Installing................................................................................5  
What’s in the Box ....................................................................................................5  
Choosing Proper Location for the Air Conditioner.................................................5  
Roof Preparation .....................................................................................................7  
Air Distribution Duct Sizing and Design .................................................................8  
Air Distribution System Installation........................................................................9  
Laying the Connecting Cables ................................................................................10  
Installation ........................................................................................11  
Installing the Rooftop Unit ......................................................................................11  
Installing the Air Distribution Box (for FACT11MA-PS/FACT11MA-PS models only,  
same for both ducted and non-ducted models, sold separately) ..........................11  
Operation...........................................................................................15  
Change the Operating Mode ...................................................................................15  
Set the Temperature ...............................................................................................15  
Troubleshooting ................................................................................16  
Cleaning and Maintenance ................................................................17  
Specifications ....................................................................................18  
Wiring Diagram .................................................................................19  
Replacement Parts List .....................................................................20  
Rooftop Air-Conditioner..........................................................................................20  
Air Distribution Box.................................................................................................22  
Warranty............................................................................................24  
2
Important Safety Instructions  
This manual has safety information and  
Handling the device  
instructions to help users eliminate  
or reduce the risk of accidents and  
injuries. Please read this instruction  
manual carefully before installation  
and start-up, and store it in a safe place  
for future reference. If you pass on the  
device to another person, hand over this  
instruction manual along with it.  
WARNING  
Installation and repair of the  
rooftop air conditioner must  
only be carried out by qualified  
personnel who are familiar with  
the risks involved and the relevant  
regulations. Inadequate repairs  
may cause serious hazards.  
The manufacturer accepts no liability  
for damage in the following cases:  
Faulty assembly or connection  
Damage to the product resulting  
from mechanical influences and  
excess voltage  
Electrical devices are not toys.  
Keep electrical devices out of reach  
of children or elderly persons. Do  
not allow them to use electrical  
devices without supervision.  
Prevent inexperienced people  
from using the device without  
supervision.  
Do not undo the upper cover of  
the rooftop air conditioner in  
the event of a fire. Use approved  
extinguishing agents instead. Do  
not use water to extinguish fires.  
Alterations to the product without  
express permission from the  
manufacturer  
Use for purposes other than those  
described in the operating manual  
The following basic safety information  
should be heeded when using  
electrical devices to protect against:  
Electric shock  
Fire hazards  
Injury  
All Furrion product referenced in  
this manual is to be installed in  
accordance with local and national  
codes, including the latest editions of  
the following standards:  
USA:  
NFPA 1192  
NFPA 70  
Canada:  
C22.1  
CSA Z240  
3
Important Safety Instructions  
Handling Electrical Cables  
CAUTION  
The rooftop air conditioner must be  
installed securely so that it cannot  
fall down.  
WARNING  
The electrical power supply must only  
be connected by a qualified electrician  
Only operate the rooftop air  
conditioner if you are certain that  
the housing and the cables are not  
damaged.  
Do not use the rooftop air  
conditioner near flammable fluids  
or in closed rooms.  
Make sure no combustible objects  
are stored or installed near the air  
outlet. A distance of at least 20”  
must be kept.  
Do not reach into air outlets or  
insert any foreign objects into the  
device.  
CAUTION  
Refer to NEC (National Electric  
Code) for proper sizing of wire  
gauge (awg) based on cable length  
and overcurrent protection rating  
that is suppling power to the air  
conditioner.  
See rooftop unit nameplate for  
proper overcurrent protection  
sizing.  
Attach and lay the cables so that  
they cannot be tripped over or  
damaged.  
Only use the device as intended.  
Do not make any alterations or  
conversions to the device.  
If faults occur in the refrigerant  
circuit, the system must be checked  
by a certified service technician and  
repaired properly. The refrigerant  
must never be released into the air.  
Only a qualified electrician should  
connect the rooftop air conditioner to  
electrical power.  
Do not lay loose or bent cables next  
to electrically conductive materials.  
Do not pull on the cables.  
Use cable ducts to lay cables through  
walls with sharp edges.  
Refer to rooftop unit nameplate and  
NEC for proper power supply rating.  
4
Before Installing  
Read this installation manual completely  
before installing the rooftop air  
conditioner.  
The following tips and instructions must  
be observed while installing the rooftop  
air conditioner.  
Filter x 2  
Decoration Plate x 1  
Control Knob x 2  
Self-tapping Screws x 4  
Instruction Manual x 1  
Warranty Card x 1  
What’s in the Box  
Choosing Proper Location for  
the Air Conditioner  
Open and remove the components  
from carton. Make sure you have all  
the following items included in the  
packaging, if any item is missing, contact  
your dealer.  
IMPORTANT: The roof must be designed  
to support the weight of the rooftop unit  
and the weight of 2 installers standing  
on the roof.  
There are two ways of installing the  
rooftop air conditioner:  
Rooftop Air Conditioner:  
Using the existing roof vent opening  
in the vehicle roof.  
Making a new opening. In this case  
the opening should be reinforced by  
an appropriate frame as required.  
Rooftop Unit  
Rooftop unit x 1  
Warranty Card x 1  
Existing Roof Vent Opening  
Air Distributor Box (sold separately):  
The air conditioner is designed to fit over  
an existing 14” roof vent opening.  
Upper Duct  
Divider  
Lower Duct  
Divider  
Bolt  
New Opening  
EVA Foam  
When no roof vent is available or another  
location is desired, the following is  
recommended:  
Mounting Frame  
Control Box  
For one unit installation - the air  
conditioner should be mounted  
slightly forward of center (front to  
back) and centered from side to side.  
For two unit installations, install  
one air conditioner one third from  
the front of the RV and the other air  
conditioner two thirds from the front  
of the RV, aligned in the center.  
It is preferred that the air conditioner  
be installed on a relatively flat and  
Filter  
ADB Shroud  
Control Knob  
Decoration Plate  
Upper Duct Divider x 1  
Lower Duct Divider x 1  
Bolt x 4  
Mounting Frame x 1  
Control Box x 1  
Air Distribution Box (ADB) Shroud x 1  
5
Before Installing  
191116”  
(500mm)  
horizontal roof section measured when  
the RV is parked on a level surface.  
NOTE: A 15° slant to either side or front  
to back is acceptable for all units. If the  
roof exceeds 15° please use an exterior  
leveling shim to make air conditioner  
level.  
23⁄4”  
(70mm)  
191116”  
(500mm)  
After the Location has been  
Selected:  
Check for obstructions in the area  
where the air conditioner will be  
installed.  
Roof  
Opening  
139⁄16”  
(345mm)  
6"  
191116”  
(500mm)  
341316”  
(884mm)  
279⁄16”  
(700mm)  
6"  
18”  
Roof Opening  
Center Line  
of Rooftop  
191116”  
(500mm)  
Front  
Keep this air flow area free of obstructions  
Check the inside of the RV for  
return air kit obstructions. (i.e. door  
openings, room dividers, curtains,  
ceiling fixtures, etc.) Allow 6”  
(152mm) space from the opening to  
account for any potential return air  
kit obstructions.  
6
Before Installing  
Roof Preparation  
3
6
m
2
m
1
m
m
4
2
¼
6
¼
4
3
1
Opening Requirements - Before  
preparing the ceiling opening, decide  
on the type of system options. Read  
all of the following instructions before  
beginning the installation.  
WARNING  
Fire/Electric Shock Hazard  
Make sure there are no obstacles  
inside the RV roof, floor and walls,  
such as wires and pipes.  
Shut off the gas supply and  
disconnect the 115VAC power from  
the RV before drilling or cutting  
into the RV. Failure to obey these  
warnings could result in death or  
serious injury.  
Making a new Opening  
If a roof vent opening will not be used,  
a 141/4” x 141/4” (+1/2”) (362mm x 362mm)  
opening must be cut through the roof  
and ceiling of the RV. This opening must  
be located between the roof reinforcing  
members.  
The 141/4” x 141/4” (+1/2”) opening is  
part of the return air system of the air  
conditioner and must be finished in  
accordance with NFPA Standard 501C  
Section 2.7.2.  
1. Mark a 141/4” x 141/4” (+1/2”) square on  
the roof and carefully cut an opening.  
Roof Thickness  
The installation of air conditioner suits  
for roof thickness from 3.5” (90mm) to  
6” (152mm). For other thickness, please  
contact Furrion or Furrion authorized  
service agent.  
Installing in an Existing Opening  
1. Unscrew and remove the roof vent.  
2. Remove all caulking compound  
around the opening.  
3
m
6
2
m
m
1
2
m
4
6
¼
¼
4
3
1
3. If the opening exceeds 141/4” x 141/4”  
(+1/2”), it will be necessary to resize  
the opening to 141/4” x 141/4” (+1/2”). If  
the opening is less than 141/4” x 141/4”  
(+1/2”), it must be enlarged.  
7
Before Installing  
2. Using the roof opening as a guide, cut  
a matching hole in the ceiling.  
NOTE: Maintain structural integrity.  
Otherwise damage to product and/or  
RV could occur. Always observe the  
following guidelines while structuring  
the opening.  
insulated and sealed. Otherwise,  
damage to roof structure and ceiling  
could occur.  
The following requirements must be met  
for properly operate the unit:  
Roof Cavity Depth 3”-6” (75mm-152mm)  
Duct Cross  
21 Sq. In. Min.  
Sectional Area  
11/2” Min. - 21/2”  
Max. (38mm  
Depth  
Min. - 63.5mm  
Max.)  
Do not cut roof  
structure or  
rafters  
Good: rafters  
supported by  
cross beams  
Good: location  
between roof  
rafters  
7” Min. - 10”  
Max. (178mm  
Width  
Min. - 254mm  
Duct Size  
3. The opening created must be framed  
to provide adequate support and  
prevent air from being drawn from  
the roof cavity.  
4. Lumber 3/4” or more in thickness  
must be used. Remember to provide  
an entrance hole for power supplies,  
wall thermostat and furnace wiring  
for connections. Leave 15” (381mm)  
minimum at the front of the opening.  
Max.)  
15Ft. Min. -  
Total Duct  
40Ft. Max. (4.5m  
Length  
- 13m)  
Duct Length  
(short run)  
1/3 Total Duct  
Length  
Number  
Required  
4 Min. - 8 Max.  
Supply Register 14 Sq. In. (90  
Free Air Area sq. cm)  
Register  
Requirements  
per A/C Unit  
Return Register 40 Sq. In. (258  
Free Air Area  
sq. cm)  
Leave access for  
power supply wiring  
3⁄4"Min.  
(19.05 mm)  
5” Min. - 8” Max.  
(127mm Min. -  
203mm Max.)  
Distance From  
Duct End  
Distance From  
Elbow  
15” (381mm)  
Total System  
Static Air  
Pressure  
Blower at High  
Speed, Filter &  
Grille In Place  
0.55 - 1.10 In.  
W.C.  
Air Distribution Duct Sizing  
Properly insulate and seal all  
discharge air ducts to prevent  
condensation from forming on their  
surfaces or adjacent surfaces during  
operation of the unit. This insulation  
must be R-7 minimum.  
and Design  
The installer of this system must design  
the air distribution system for their  
particular application.  
NOTE: Make sure ductwork will NOT  
bend or collapse during and after  
installation, and that it is correctly  
8
Before Installing  
NOTE: Alternate configurations and  
methods may be used which will allow  
the unit to operate properly, however,  
these alternate configurations and  
methods MUST be approved by Furrion  
in writing.  
TOP VIEW  
(BACK OF RV)  
Frame  
Duct  
Duct  
Duct size  
Roof  
Opening  
Duct layout  
Register size  
Frame  
Frame  
Register location  
Thermostat location  
Indoor temperature sensor location  
(if applicable)  
SIDE VIEW  
(TOWARD BACK OF RV)  
Front  
Roof  
Registers 4  
Min - 8 Max.  
(Per Unit) 14  
Sq. In. Free  
Area Per  
Register  
Roof Opening  
Duct  
Duct  
Return Air  
Ceiling  
Return air openings must have  
80 square inches (516 square  
centimeters) minimum free area  
including the filter.  
Air Conditioner  
Return air to the unit must be filtered  
to prevent dirt accumulation on the  
unit cooling surface.  
Air Distribution System  
Installation  
It is the responsibility of the installer to  
review each RV floor plan to determine  
the following items in conjunction with  
“Air Distribution Duct Sizing and Design”  
section on Page 8.  
9
Before Installing  
1. Refer to the applicable electric code  
guidelines for sizing the appropriate  
wire gauge, length and type.  
2. Route a 115VAC supply wire with  
ground wire from the time delay fuse  
or circuit breaker box to the roof  
opening.  
Laying the Connecting Cables  
The rooftop air conditioner must be  
connected to an electric circuit which is  
able to supply the required power supply  
(see chapter “Specification”).  
NOTE: The supply wire must be located  
in the front portion of the roof opening.  
The power supply must be equipped with  
a time delay fuse or circuit breaker. See  
rooftop unit nameplate for rating.  
NOTE: Refer to rooftop unit  
nameplate and applicable code for  
proper installation.  
3. Use approved method to protect the  
wire where it passes through the  
opening.  
4. Feed the 115VAC cable through the  
opening into the vehicle interior.  
Make sure at least 15” (381mm) of  
supply wire extends into the roof  
opening. This ensures an easy  
connection at the control box.  
5. We can seal off any gaps if find the air  
leakage, other than the duct work or  
inlet air with foil tape.  
DANGER  
Electrical Shock Hazard  
Disconnect power before servicing.  
Failure to obey this warning could  
result in death or serious injury.  
Provide grounding in compliance  
with all applicable electrical codes.  
Failure to obey this warning could  
result in death or serious injury.  
10  
Installation  
Installing the Rooftop Unit  
Installing the Air Distribution  
Box (for FACT11MA-PS/  
FACT11MA-PS models only,  
same for both ducted and  
non-ducted models, sold  
separately)  
CAUTION  
The rooftop unit weighs  
approximately 100 pounds (45  
kg). To prevent back injury, use a  
mechanical hoist when lifting or  
moving the unit. Failure to obey this  
warning could result in injury.  
Do not slide unit. It may damage  
the gasket at the bottom of the  
rooftop unit and cause leakage.  
Do not grasp the ventilation slots to  
lift the rooftop unit up.  
The rooftop unit is fixed on the RV roof  
using 4 long bolts through the mounting  
frame from the interior of the RV ceiling.  
1. Check the gasket alignment of the  
rooftop unit inside the RV over the  
roof opening and adjust as necessary  
by lifting and moving slightly. (Fig. 2)  
1. Grasp the bottom of two sides of the  
unit, lift and position the rooftop unit  
into the prepared opening using the  
gasket at the bottom of the rooftop  
unit as a guide. (Fig. 1)  
Roof Opening  
Fig. 2  
This Side is  
Facing Forward  
2. Reach up into the return air opening  
and pull the rooftop unit electric cord  
and 115VAC power cord down from  
the cutout area for later connection.  
(Fig. 3)  
Roof Opening  
Fig. 1  
This completes the outside installation  
of the rooftop unit. Minor adjustments  
can be done from inside of the RV if  
required.  
Roof Opening  
Ceiling Thickness  
115VAC  
Rooftop Unit  
Power Cord  
Cable  
Fig. 3  
11  
Installation  
3. Install the assembled mounting  
frame and the lower duct divider into  
the rooftop opening. Make sure the  
“THIS WAY FRONT” mark is facing  
front (the direction of the vehicle)  
while installing. (Fig. 4)  
5. Stick the upper duct divider into the  
assembled mounting frame.  
NOTE: Make sure the upper duct  
divider is pressing against the ceiling  
before finally sticking it. (Fig. 6)  
Upper Duct  
Divider  
Fig. 6  
Fig. 4  
6. Peel to remove the release paper  
from the EVA foam, overlap the sticky  
side over all gaps and compress to  
seal and insulate the entire section.  
(Fig. 7)  
4. Fix the assembled mounting frame  
and lower duct divider into the rooftop  
unit using 4 bolts provided. (Fig. 5-a)  
Pull to remove the film off the double  
sided sticky tape on the inner side of  
the lower duct divider. (Fig. 5-b)  
NOTE: If bolts are left loose there  
may not be an adequate roof seal or  
if over tightened, damage may occur  
to the rooftop base or mounting  
frame. Evenly tighten the four bolts  
to a torque of 40 to 50 inch pounds.  
This will compress the roof gasket to  
approximately 1/2”.  
PE Foam  
Fig. 7  
7. Remove the cable compartment cover  
using a Phillips screw driver. (Fig. 8)  
a
b
Fig. 8  
Fig. 5  
12  
Installation  
10.Fit all cables into the cable  
compartment and tuck any excess  
wires up out of the way. Tighten the  
cover with screw. (Fig. 10)  
DANGER  
Electrical Shock Hazard  
Disconnect power before servicing.  
Failure to obey this warning could  
result in death or serious injury.  
Provide grounding in compliance  
with all applicable electrical codes.  
Failure to obey this warning could  
result in death or serious injury.  
8. Loosen the cable clip on top of the  
control box and pass the 115VAC  
power cord through the cable clip.  
Make the 115VAC power supply  
connection to the control box and  
ensure they are properly insulated by  
using twist caps. (Fig. 9)  
Fig. 10  
11. Connect the wires of the rooftop unit  
cable to the control box. (Fig. 11)  
115VAC Power Cord: Connect to  
115VAC power source  
NOTE: Always follow the color code  
while connecting the cables.  
115VAC Power  
Cord  
Rooftop Unit  
Cable  
Fig. 11  
Fig. 9  
9. Tighten the cable clip until the cable  
is snapped tightly.  
NOTE: Do not over tighten.  
13  
Installation  
12.Install the Air Distribution Box (ADB)  
shroud over the mounting frame and  
fix with 4 self-tapping screws.  
NOTE: Make sure the “THIS WAY  
FRONT” mark is facing front (the  
direction of the vehicle) while  
installing. (Fig. 12)  
14.Align the decoration plate tabs  
with the mating notches on the  
ADB shroud and push to snap the  
decoration plate into place. (Fig. 14)  
Fig. 14  
15.Install the two control knobs through  
holes on the decoration plate and  
push to lock into place. (Fig. 15)  
Fig. 12  
13.Align the filter tabs with mating  
notches and push to snap the filters  
into the ADB shroud. (Fig. 13)  
Fig. 15  
16.Your new rooftop air conditioner has  
now been fully installed in the RV  
roof. (Fig. 16)  
Fig. 13  
Fig. 16  
14  
Operation  
Your new rooftop air conditioner is de-  
signed with 2 control knobs which allow  
you to set the temperature set-point and  
change the operating mode of the air  
conditioner.  
Set the Temperature  
Set the temperature to your comfort  
level by rotating the temperature control  
knob. The fan will run continuously to  
circulate the air and maintain an even  
temperature.  
Change the Operating Mode  
NOTE: The designed temperature setting  
range is 64ºF (18ºC) at the coldest to  
86ºF (30ºC) at the warmest. The tem-  
perature setting mode is only available  
while cooling mode is selected.  
Rotate the operating control mode knob  
to select the desired operating mode.  
There are 3 available operating modes  
for you to select.  
1. Rotate the operating mode control  
knob to the cool position.  
2. Rotate the temperature control knob  
to your desired level.  
FAN MODE  
Rotate the operating mode control knob  
to the FAN position.  
COOL MODE  
Rotate the operating mode control knob  
to the COOL position.  
OFF MODE  
Rotate the operating mode control knob  
to the OFF position.  
15  
Troubleshooting  
Problem  
Cause  
Remedy  
Outer temperature is too low or all air nozzles are  
closed.  
Rooftop air  
conditioner constantly Freeze sensor has tripped.  
switches itself off  
The rooftop air conditioner is not  
set to cooling.  
Set the rooftop air conditioner to cooling.  
Select a lower temperature.  
The room temperature is higher  
than set-point temperature.  
Contact an authorized service agent or Furrion (see the  
detail contact info at the back page of this manual).  
The evaporator fan is damaged.  
Not cooling well  
Contact an authorized service agent or Furrion (see the  
detail contact info at the back page of this manual).  
The condenser fan is damaged.  
The air intake grilles are blocked  
or obstructed.  
Remove any leaves and other dirt from the ventilation  
grilles of the rooftop air conditioner.  
Contact an authorized service agent or Furrion (see the  
detail contact info at the back page of this manual).  
The blower is defective.  
The condensation water drainage  
openings are clogged up.  
Clean the drainage openings for condensation water.  
Water enters the  
vehicle  
Contact an authorized service agent or Furrion (see the  
detail contact info at the back page of this manual).  
The seals are damaged.  
No supply voltage connected.  
Check the power supply.  
Rooftop air  
Contact an authorized service agent or Furrion (see the  
detail contact info at the back page of this manual).  
The voltage is too low.  
conditioner does not  
switch on  
Fuse blown or circuit protector  
tripped.  
Check the electrical fuse of the power supply.  
16  
Cleaning and Maintenance  
A blocked filter will impair the cooling  
and heating performance of the unit  
significantly.  
The filter must be cleaned periodically to  
ensure that it does not become clogged  
with dust and other particles. The state  
of the filter can be ascertained from its  
appearance. If it appears dirty or clogged  
Fig. 18  
then it should be cleaned.  
3. The filter can be washed with warm  
soapy water. Care must be taken to  
avoid ripping the fabric.  
WARNING  
Airborne particles can pose a health  
risk, particularly to young children  
and the elderly. Ensure that filters  
are cleaned in a safe and well  
ventilated area.  
4. Replace the filters, decoration plate  
and control knobs by reversing the  
above process.  
NOTE: The filter must be completely  
dry before re-installation.  
To Replace the Filter  
To Clean the Filter  
Filter changes should be carried out  
depending on the amount of use, it  
is recommended to change at least  
every 12 months. Never operate the  
air conditioning system without a filter,  
since this can decrease performance  
and indoor air quality.  
The filter should be cleaned every four  
weeks or more when in use. Prolonged  
use, higher concentrations of airborne  
particles and various other factors may  
result in the filters needing to be cleaned  
more often.  
1. Pull the two control knobs to remove  
from the air conditioning switch.  
Remove the decoration plate from the  
air conditioning system by pushing  
the side tabs to release. (Fig. 17)  
Replacement return air filters can be  
ordered directly from Furrion.  
Fig. 17  
2. Remove the filters by pushing the  
tabs to release. (Fig. 18)  
17  
Specifications  
Specification  
PERFORMANCE  
FACR13SA-PS  
FACR13SA-BL  
FACR14SA-PS  
FACR14SA-BL  
FACR15SA-PS  
FACR15SA-BL  
Model Number  
Cooling Capacity (Btu/h)  
Dehumidification (pint/h)  
13,500  
14,500  
2.7  
15,500  
3.2  
2.5  
Applicable vehicle length (feet)  
Refrigerant  
23  
26  
31  
R410A  
15.9  
R410A  
19.8  
R410A  
23.1  
Charge (Oz)  
Roof top Unit Dimensions (L x W x H)  
(inch)  
347/8 x 275/8 x 135/8  
347/8 x 275/8 x 135/8  
347/8 x 275/8 x 135/8  
ELECTRICAL  
Volts/Frequency  
115V~/60Hz/1Ph  
1450  
115V~/60Hz/1Ph  
1620  
115V~/60Hz/1Ph  
1720  
Power Watts (Cooling)  
Amps (Cooling)  
13.1  
14.6  
15.4  
Power Cord Gauge Min. (mm2)  
AWG12  
AWG12  
AWG12  
18  
Wiring Diagram  
DANGER  
Electrical Shock Hazard  
Disconnect power before servicing. Failure to obey this warning could result in  
death or serious injury.  
Provide grounding in compliance with all applicable electrical codes. Failure to  
obey this warning could result in death or serious injury.  
COMPRESSOR  
C
GRN/YEL  
INDOOR  
MOTOR  
OUTDOOR  
MOTOR  
BLK  
R
S
GRN/YEL  
PASSED  
DIELECTRIC  
GRN/YEL  
O.L  
6PIN CONN  
BLU  
BLU  
BRN  
1
2
3
WHT  
RED  
WHT  
BLK  
YEL  
RED  
WHT  
IF  
COM  
CP  
WHT  
RED  
4
5
6
OF  
GRN/YEL  
CAPACITOR  
RED  
FUSE  
HEAT ELEMENT  
HEAT ELEMENT  
3PIN CONN  
RED  
RED  
BLK  
BLK  
3
LIMMITED SWITCH  
2
1
RED  
BLK  
RED  
115VAC 60HZ 1PH  
USE COPPER  
CONDUCTORS ONLY  
FIELD WIRING  
FACTORY WIRING  
LINE SPLICE  
GRN/YEL  
WHT  
BLK  
WHT  
GRY  
1 L1  
2 H  
4 C  
ROTARY  
SWITCH  
BLK  
YEL  
RED  
BLU  
BLU  
ELEC CONN  
FROM UPPER  
UNIT  
PASSED DIELECTIC  
THERMOSTAT  
19  
Replacement Parts List  
Rooftop Air-Conditioner  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
20  
Replacement Parts List  
Item  
Part#  
Description  
1
C-FACR15SA-001  
C-FACR15SA-002  
C-FACR15SA-008  
C-FACR15SA-003  
C-FACR15SA-007  
C-FACR15SA-006  
C-FACR15SA-004  
C-FACR15SA-005  
C-FACR15SA-009  
C-FACR15SA-PS-010  
C-FACR15SA-BL-010  
C-FACR15SA-PS-011  
C-FACR15SA-BL-011  
Top Cover  
2
Clip Nut  
3
Evaporator Fan  
Evaporator Fan Motor  
Condenser Fan  
Condenser Fan Motor  
Capacitor  
4
5
6
7
8
Eva Gasket  
9
Strengthen Metal Plate  
Roof Gasket  
10  
11  
12  
13  
Indicator  
Leveling Shim  
Filter Grill  
21  
Replacement Parts List  
Air Distribution Box  
1
2
3
4
22  
Replacement Parts List  
Item  
Part#  
Description  
1
2
3
C-FACT11MA-002  
Manual Control Box  
C-FACT12SA-PS-006  
C-FACT12SA-PS-007  
C-FACT12SA-BL-007  
C-FACT11MA-PS-008  
C-FACT11MA-BL-008  
ADB shroud (White)  
Filter (White)  
Filter (Black)  
4
Control knob For Manual Trim kit (White)  
Control knob For Manual Trim kit (Black)  
23  
Warranty  
FURRION WARRANTS FOR A PERIOD OF 1 YEAR FROM DATE OF RETAIL PURCHASE  
BY THE ORIGINAL END-USE PURCHASER, THAT THIS PRODUCT, WHEN DELIVERED  
TO YOU IN NEW CONDITION, IN ORIGINAL PACKAGING, FROM A FURRION  
AUTHORIZED RESELLER AND USED IN NORMAL CONDITIONS, IS FREE FROM  
ANY DEFECTS IN MANUFACTURING, MATERIALS, AND WORKMANSHIP. IN CASE  
OF SUCH DEFECT, FURRION SHALL REPLACE OR REPAIR THE PRODUCT AT NO  
CHARGE TO YOU. THIS WARRANTY DOES NOT COVER: PRODUCTS WHERE THE  
ORIGINAL SERIAL NUMBERS HAVE BEEN REMOVED, ALTERED OR CANNOT  
READILY BE DETERMINED; DAMAGE OR LOSS CAUSED BY ACCIDENT, MISUSE,  
ABUSE, NEGLECT, PRODUCT MODIFICATION, FAILURE TO FOLLOW INSTRUCTIONS  
IN INSTRUCTION MANUAL, COMMERCIAL OR INDUSTRIAL USE; DAMAGE OR LOSS  
CAUSED TO THE DECORATIVE SURFACE OF PRODUCT; TO ANY DATA, SOFTWARE OR  
INFORMATION; AND NORMAL WEAR AND TEAR. THIS WARRANTY ONLY PROTECTS  
THE ORIGINAL END-USER (“YOU”) AND IS NOT TRANSFERABLE; ANY ATTEMPT TO  
TRANSFER THIS WARRANTY SHALL MAKE IT IMMEDIATELY VOID. THIS WARRANTY  
IS ONLY VALID IN THE COUNTRY OF PURCHASE.  
THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN  
LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER  
ORAL OR WRITTEN, EXPRESS OR IMPLIED. FURRION SPECIFICALLY DISCLAIMS  
ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION,  
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  
IF FURRION CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS  
LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO  
THE DURATION OF THIS WARRANTY.  
No Furrion reseller, agent, or employee is authorized to make any modification,  
extension, or addition to this warranty.  
24  
Warranty  
FURRION IS NOT RESPONSIBLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR  
CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR  
CONDITION, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED  
TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPLACEMENT OF  
ANY EQUIPMENT OR PROPERTY, ANY COSTS OF RECOVERING, REPROGRAMMING,  
OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH FURRION  
PRODUCTS. FURRION’S TOTAL LIABILITY IS LIMITED TO THE REPAIR OR  
REPLACEMENT OF THIS PRODUCT PURSUANT TO THE TERMS OF THIS WARRANTY.  
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR  
CONSEQUENTIAL DAMAGES OR EXCLUSIONS OR LIMITATIONS ON THE DURATION  
OF IMPLIED WARRANTIES OR CONDITIONS, SO THE ABOVE LIMITATIONS OR  
EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL  
RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY BY STATE OR (WHERE  
APPLICABLE IN THE COUNTRIES WHERE FURRION HAS NON-US/CANADIAN  
AUTHORIZED DEALERS) COUNTRY. NO ACTION OR CLAIM TO ENFORCE THIS  
WARRANTY SHALL BE COMMENCED AFTER THE EXPIRATION OF THE WARRANTY  
PERIOD.  
Keep your receipt, delivery slip, or other appropriate payment record to establish the  
warranty period. Service under this warranty must be obtained by contacting Furrion  
at warranty@furrion.com  
Product features or specifications as described or illustrated are subject to change  
without notice.  
25  
26  
Furrion Innovation Center & Institute of Technology  
● 52567 Independence Ct., Elkhart, IN 46514, USA ● Toll free:1-888-354-5792  
● Email: [email protected]  
©2007-2018 Furrion Ltd. Furrion® and the Furrion logo are trademarks licensed for use by  
Furrion Ltd. and registered in the U.S. and other countries.  
FURRION.COM  
IM-FAV00033 V2.0  

Whirlpool Acq082xk1 User Manual
Sterling Power Products Ab2460 User Manual
Sharp Mx 4101n User Manual
Sanyo Cr2430 User Manual
Samsung Sh07zpga User Manual
Murphy Bc3012 User Manual
MAYTAG MVWC500VW1 User Manual
HITACHI 53UWX10BA User Manual
DELLĀ E1909W User Manual
ACER ASPIRE R 14 R3 471TG User Manual