ATLAS METAL WIH 3 User Manual

WH/WIH/WIHL  
Service and Installation Manual  
Please read this manual completely before attempting to install or operate this equipment!  
Notify carrier of damage! Inspect all components immediately. See page 1.  
Drop-in Hot Pans  
Effective Date: 2020  
IMPORTANT INFORMATION  
READ BEFORE USE  
Specifications subject to change without notice.  
Project: ___________  
Item No.:ꢀ ___________  
Quantity:ꢀ ___________  
DROP-IN SERVING EQUIPMENT  
WH-2  
HOT PAN  
Electrically Heated  
Single Control  
WH-3  
WH-4  
WH-5  
WH-6  
WH-3  
SPECIFICATIONS  
STANDARD FEATURES  
TOP: Constructed of 18 gauge, type 304 stainless steel, die  
stamped flange with a raised perimeter bead. There shall be  
a solid vinyl gasket under the beaded edge to form a seal to  
the counter top, thus preventing seepage or marring of the  
counter top. Embossed mounting lugs are provided along the  
inner surface of the top to hold the removable separator  
channels in place.  
g
Fully insulated to retain heat - protects fixtures and  
saves energy  
g
g
g
Open Bain Marie construction  
Thermostatically controlled  
Factory applied gasket - makes installation a snap and  
seals units to the counter top, thus eliminating seepage  
Accommodates standard 12” X 20” pans with the use  
of separator channel(s), or fractional size pans with  
the use of optional adapter bars  
Wet or Dry Operation  
1-Year Parts & Labor Warranty  
UL Listed, ETLꢀListed  
g
LINER: The inner liner shall be 18 gauge, type 304 stainless  
steel, one piece construction, all welded ground and polished  
to a uniform finish. All corners are coved with a minimum 1/4"  
radius. A 3/4" dia. drain, with strainer, brass nipple, and valve  
is provided.  
g
g
g
INSULATION: The pan is fully insulated with high density  
fiberglass insulation, 1" thick on all sides, 2" thick on the bot-  
tom and enclosed by a 22 gauge galvanized steel outer case.  
ACCESSORIES  
g
g
Stainless steel adapter bars (pgs. DI-51-52)  
Stainless steel adapter plates (pgs. DI-51-52)  
ELECTRICAL: The unit is provided with individual 850 watt  
heating elements, pre-wired to a single thermostat control  
with a pilot light. A 6’ long, 3-wire cord and plug is provided,  
extending from the control box located under the unit, on  
operator's left. Bottom of outer case can be removed for ac-  
cess to electrical components. Available for single phase  
power only.  
g CP - Cover Plate with handles, S/S  
g
RDVE - Rear Drain Valve Extension (1) required  
RT-1 - Remote Thermostat for counter installation, 24”  
g
long  
g
RTL-1 - Remote Thermostat for counter installation,  
50” long  
MS - Master on/off switch  
g AF - Automatic water fill  
Specifications subject to change without notice.  
g
*Please see Operation &ꢀInstallation Manual for ALL operation and maintenance details.  
DI-1  
A
12”  
12”  
24”  
PLAN VIEW  
REMOVABLE SEPARATOR  
CHANNEL  
19-7/8” ID  
6” ID  
9”  
2-5/8”  
3-3/4”  
2-1/2”  
ELEVATION  
END VIEW  
7-1/4”  
4-1/8”  
3-3/4”  
Electrical Characteristics  
NEMA  
# PLUG  
MODEL WATTAGE VOLTAGE/KW/AMPS  
5-20P  
6-15P  
6-15P  
120V - 1.7KW - 14.2  
COUNTER  
WH-2  
850WATT  
208V - 1.7KW - 8.2  
240V - 1.7KW - 7.1  
CUT-OUT  
SHIP WT.  
MODEL  
“A”  
PAN SIZE  
(REQUIRED)  
W X L  
(LBS.)  
5-30P  
6-15P  
6-15P  
120V - 2.0KW 16.7  
208V - 2.0KW - 9.6  
240V - 2.0KW - 8.3  
1000WATT  
850WATT  
WH-2  
29-3/4”  
19-7/8” X 25-1/2” X 6”  
22-1/4” X 28”  
116  
(75.5cm) (50.4 X 64.7 X 15.2cm) (56.5 X 71.1cm) (52.6kg)  
5-30P  
L6-20P  
6-15P  
120V - 2.55KW - 21.3  
208V - 2.55KW - 12.3  
240V - 2.55KW - 10.6  
WH-3  
WH-4  
WH-3  
WH-4  
WH-5  
WH-6  
43-1/2”  
19-7/8” X 39-1/4” X 6” 22-1/4” X 41-3/4”  
(110.4cm) (50.4 X 99.6 X 15.2cm) (56.5 X 106cm) (67.1kg)  
148  
57-1/4” 19-7/8” X 53” X 6” 22-1/4” X 55-1/2” 174  
5-50P  
L6-20P  
L6-20P  
L6-30P  
L6-20P  
120V - 3.0KW - 25.0  
208V - 3.0KW - 14.4  
240V - 3.0KW - 12.5  
208V - 3.4KW - 16.4  
240V - 3.4KW - 14.2  
1000WATT  
850WATT  
(145.4cm) (50.4 Xꢀ134.6 Xꢀ15.2cm) (56.5 X 140cm) (78.9kg)  
71” 19-7/8” X 66-3/4” X 6” 22-1/4” X 69-1/4” 210  
(180.3cm) (50.4 X 169.5 X 15.2cm) (56.5 Xꢀ175.8cm) (95.3kg)  
84-3/4” 19-7/8” X 80-1/2” X 6” 22-1/4” X 83” 227  
(215.2cm) (50.4 Xꢀ204.4 Xꢀ15.2cm) (56.5 Xꢀ210.8cm) (102.9kg)  
L6-30P  
L6-30P  
208V - 4.0KW - 19.2  
240V - 4.0KW - 16.7  
1000WATT  
850WATT  
1000WATT  
850WATT  
1000WATT  
Note: Numeral following the model letters denotes the 12X20 pan capacity  
L6-30P  
L6-30P  
208V - 4.25KW - 20.4  
240V - 4.25KW - 17.7  
WH-5  
WH-6  
L6-30P  
L6-30P  
208V - 5.0KW - 24.0  
240V - 5.0KW - 20.8  
6-50P  
L6-30P  
208V - 5.1KW - 24.5  
240V - 5.1KW - 21.3  
6-50P  
6-50P  
208V - 6.0KW - 28.8  
240V - 6.0KW - 25.0  
Atlas Metal Industries 1135 NWꢀ159th Dr. Miami, FL 33169 (800) 762-7565 Fax: (305) 623-0475 atlasfoodserv.com  
2/20-sc  
DI-2  
Project: ___________  
Item No.:ꢀ ___________  
Quantity:ꢀ ___________  
DROP-IN SERVING EQUIPMENT  
WIH-1  
WIH-2  
HOT PAN  
WIH-3  
WIH-4  
WIH-5  
WIH-6  
Electrically Heated  
Individual Controls  
WIH-3  
SPECIFICATIONS  
STANDARD FEATURES  
g
g
g
Fully insulated to retain heat - protects fixtures and  
saves energy  
TOP: Constructed of 18 gauge, type 304 stainless steel, die  
stamped with a raised perimeter bead. There shall be a solid  
vinyl gasket under the beaded edge to form a seal to the  
counter top, thus preventing seepage or marring of the  
counter top.  
Individual thermostat controls - the operator can  
control the temperature of each well separately  
Factory applied gasket - makes installation a snap  
and seals units to the counter, thus eliminating  
seepage  
Accommodates standard 12”x20” pans, or fractional  
size pans with the use of optional adapter bars  
Wet or Dry Operation  
HOT FOOD WELLS: Individual hot food wells shall be 18  
gauge, type 304 stainless steel, one piece construction, all  
welded, ground and polished to a uniform finish. All corners  
are coved with a minimum 1/4" radius. Each well is provided  
with an 850 watt heating element (1000 watt on the WIH-1).  
g
g
g
g
1-Year Parts & Labor Warranty  
UL Listed, ETLꢀListed  
INSULATION: The pan is fully insulated with high density  
fiberglass, 1" thick on all sides, 2" thick on the bottom and en-  
closed with a 22 gauge galvanized steel outer case.  
ACCESSORIES  
g
g
g
Stainless steel adapter bars (pg DI-51-52)  
Stainless steel adapter plates (pg DI-51-52)  
CP - Cover Plate with handles, S/S  
ELECTRICAL: The unit is provided with an individual  
thermostat control with a pilot light for each well. All heating  
elements and controls are pre-wired, and a 6' long, 3-wire  
cord and plug is provided, extending from the control box  
located under the unit, on operator's left. Bottom of outer  
case can be removed for access to electrical components.  
g D - Individual Drain and Valve for each well (3/4” dia.  
drain)  
g
DM - Individual Drain for each well with manifold to  
single valve  
g
DMV - Individual Drain with valve for each well with  
Specifications subject to change without notice.  
manifold to single valve  
g
DME - Individual drain for each well with manifold to  
single valve w/ rear extension  
g
RDVE - Rear Extension for D, DM, & DMV (1)  
required  
g RT - Remote Thermostats for counter installation, 24”ꢀ  
long  
g RTL - Remote Thermostats for counter installation, 50”  
long  
g MS - Master on/off switch  
g AFꢀ- Automatic water fill (NOTE: DM required for water  
fill)  
*Please see Operation &ꢀInstallation Manual for ALL operation and maintenance details.  
DI-3  
A
24”  
SHOWN WITH OPTIONAL DME -  
DRAIN AND MANIFOLD WITH  
REAR EXTENSION  
PLAN VIEW  
19-7/8” ID  
6” ID  
9”  
3-3/4”  
5-1/4”  
7-1/2”  
ELEVATION  
END VIEW  
2-1/8”  
Electrical Characteristics  
NEMA #  
PLUG  
5-15P  
6-15P  
6-15P  
MODEL WATTAGE VOLTAGE/KW/AMPS  
120V - 1.0KW -8.3  
WIH-1  
1000WATT  
208V - 1.0KW - 4.8  
240V - 1.0KW - 4.2  
COUNTER  
CUT-OUT  
(REQUIRED)  
W X L  
22-1/4” X 14-1/4”  
(56.5 X 36.8cm)  
CONTROL  
PANEL  
SHIP WT.  
(LBS.)  
120V - 1.7KW - 14.2  
208V - 1.7KW - 8.2  
240V - 1.7KW - 7.1  
120V - 2.0KW - 16.7  
208V - 2.0KW - 9.6  
240V - 2.0KW - 8.3  
120V - 2.55KW - 21.3 L5-30P  
208V - 2.55KW - 12.3  
240V - 2.55KW - 10.6  
120V - 3.0KW - 25.0  
208V - 3.0KW - 14.4  
240V - 3.0KW -12-5  
208V - 3.4KW - 16.4  
240V - 3.4KW - 14.2  
208V - 4.0KW - 19.2  
240V - 4.0KW - 16.7  
208V - 4.25KW - 20.4 L6-30P  
240V - 4.25KW - 17.7  
208V - 5.0KW - 24.0  
240V - 5.0KW - 20.8  
208V - 5.1KW - 24.5  
240V - 5.1KW - 21.3  
5-20P  
6-15P  
6-15P  
L5-30P  
6-15P  
6-15P  
MODEL  
“A”  
WIH-2  
850WATT  
1000WATT  
850WATT  
1000WATT  
850WATT  
CUT-OUT  
(IF REQUIRED)  
4-1/2” X 6-1/4”  
(11.4 X 15.8cm)  
4-1/2” X 12-1/4”  
(11.4 x 31.1cm)  
4-1/2” X 26”  
(11.4 Xꢀ66cm)  
WIH-1  
16”  
(40.6cm)  
41  
(18.5kg)  
112  
(50.8kg)  
152  
(68.9kg)  
WIH-2 29-3/4”  
22-1/4” X 28”  
(56.5 Xꢀ71.1cm)  
22-1/4” X 41-3/4”  
(110.4cm) (56.5 X 111.1cm)  
(75.5cm)  
WIH-3  
WIH-4  
L6-20P  
6-15P  
5-50P  
L6-20P  
L6-20P  
L6-30P  
L6-20P  
L6-30P  
L6-30P  
WIH-3 43-1/2”  
WIH-4 57-1/4”  
22-1/4” X 55-1/2”  
(145.4cm) (56.5 X 140.9cm) (11.4 X 100.9cm)  
4-1/2’ X 39-3/4”  
188  
(85.3kg)  
225  
(102kg)  
268  
(121.5kg)  
WIH-5  
71”  
(180.3cm) (56.5 X 175.8cm) (11.4 X 135.8cm)  
WIH-6 84-3/4” 22-1/4” X 83” 4-1/2” X 67-1/4”  
(213.3cm) (56.5 X 210.8cm) (11.4 X 170.8cm)  
22-1/4” X 69-1/4”  
4-1/2” X 53-1/2”  
1000WATT  
850WATT  
1000WATT  
850WATT  
1000WATT  
Note: Numeral following the model letters denotes the 12X20 pan capacity  
WIH-5  
WIH-6  
L6-30P  
L6-30P  
L6-30P  
6-50P  
L6-30P  
6-50P  
6-50P  
208V - 6.0KW - 28.8  
240V - 6.0KW - 25.0  
Atlas Metal Industries 1135 NWꢀ159th Dr. Miami, FL 33169 (800) 762-7565 Fax: (305) 623-0475 atlasfoodserv.com  
2/20-sc  
DI-4  
Project: ___________  
Item No.:ꢀ ___________  
Quantity:ꢀ ___________  
SLIM-LINE DROP-IN SERVING EQUIPMENT  
SLIM-LINE  
WIHL-2  
HOT PAN  
WIHL-3  
Electrically Heated  
Individual Controls  
WIHL-4  
WIHL-2  
SPECIFICATIONS  
STANDARD FEATURES  
g
g
g
g
TOP: Constructed of 18 gauge, type 304 stainless steel, die  
stamped with a raised perimeter bead. There shall be a solid  
vinyl gasket under the beaded edge to form a seal to the  
counter top, thus preventing seepage or marring of the  
counter top.  
Slim line configuration - it can install in counters only  
16” wide  
Fully insulated to retain heat - protects fixtures  
and saves energy  
Individual thermostat controls - the operator can  
control the temperature of each well separately  
Factory applied gasket - makes installation a snap and  
seals units to the counter top, thus eliminating  
seepage  
HOT FOOD WELLS: Individual hot food wells shall be 18  
gauge, type 304 stainless steel, one piece construction, all  
welded, ground and polished to a uniform finish. All corners  
are coved with a minimum 1/4" radius. Each well is provided  
with an 850 watt heating element.  
g Accommodates standard 12”ꢀX 20” pans, or fractional  
size pans with the use of optional adapter bars.  
Wet or Dry Operation  
1-Year Parts & Labor Warranty  
INSULATION: The pan is fully insulated with high density  
fiberglass insulation, 1" thick on all sides, 2" thick on the  
bottom, and enclosed by a 22 gauge galvanized steel outer  
case.  
g
g
g
UL Listed, ETAL LCisCtedESSORIES  
ELECTRICAL: The unit is provided with an individual  
thermostat control and pilot light for each well. All heating  
elements and controls are pre-wired, and a 6' long, 3-wire  
cord and plug is provided, extending from the control box  
located under the unit, on operator's left. Bottom of outer  
case can be removed for access to electrical components.  
g
Stainless steel adapter bars (pg DI-51-52)  
g
Stainless steel adapter plates (pg DI-51-52)  
g
CPL - Cover Plate with handles, S/S  
g D - Individual Drain and Valve for each well (3/4” dia.  
drain)  
g
DM - Individual Drain for each well with manifold to  
single valve  
Specifications subject to change without notice.  
g
DMV - Individual Drain with valve for each well with  
manifold to single valve  
g
DME - Individual drain for each well with manifold to  
single valve w/ rear extension  
g
RDVE - Rear Extension for D, DM, DMV & DME (1)  
required  
g RT - Remote Thermostats for counter installation, 24”ꢀ  
long  
g RTL - Remote Thermostats for counter installation, 50”  
long  
g MS - Master on/off switch  
g AFꢀ- Automatic water fill (NOTE: DM required for water  
fill)  
*Please see Operation &ꢀInstallation Manual for ALL operation and maintenance details.  
DI-5  
A
11-7/8” ID  
6”  
9”  
16”  
3-3/4”  
2-1/2”  
3-3/4”  
10-1/4”  
PLAN VIEW  
ELEVATION  
END VIEW  
Electrical Characteristics  
NEMA  
# PLUG  
MODEL WATTAGE VOLTAGE/KW/AMPS  
120V - 1.7KW - 14.2 5-20P  
WIHL-2 850WATT  
1000WATT  
208V - 1.7KW - 8.2  
6-15P  
COUNTER  
CUT-OUT  
CONTROL  
240V - 1.7 KW - 7.1 6-15P  
120V - 2.0KW - 16.7 5-30P  
SHIP  
WT.  
PANEL  
CUT-OUT  
MODEL  
“A”  
(REQUIRED)  
W X L  
208V - 2.0KW - 9.6  
240V - 2.0KW - 8.3  
6-15P  
6-15P  
(LBS.)  
(IF REQUIRED)  
120V - 2.55KW - 21.3 5-30P  
208V - 2.55KW - 12.3 L6-20P  
240V - 2.55KW - 10.6 6-15P  
120V - 3.0KW - 25.0 5-50P  
208V - 3.0KW - 14.4 L6-20P  
240V - 3.0KW - 12.5 L6-20P  
208V - 3.4KW - 16.4 L6-30P  
240V - 3.4KW - 14.2 L6-20P  
46”  
14-1/4” X 44-1/4” 4-1/2” X 12-1/4”  
(116.8cm) (36.8 X 113.6cm) (11.4 Xꢀ31.1cm) (53.5kg)  
118  
WIHL-2  
WIHL-3  
WIHL-4  
WIHL-3 850WATT  
1000WATT  
67-3/4”  
14-1/4” X 66”  
4-1/2” X 26”  
176  
(172cm) (36.8 X 167.6cm) (11.4 Xꢀ66cm) (79.8kg)  
89-1/2” 14-1/4” X 87-3/4” 4-1/2” 39-3/4” 210  
(227.3cm) (36.8 Xꢀ222.8cm) (11.4 X 100.9cm) (95.2kg)  
WIHL-4 850WATT  
1000WATT  
Note: Numeral following the model letters denotes the 12X20 pan capacity  
208V - 4.0KW - 19.2 L6-30P  
240V - 4.0KW - 16.7 L6-30P  
Atlas Metal Industries 1135 NWꢀ159th Dr. Miami, FL 33169 (800) 762-7565 Fax: (305) 623-0475 atlasfoodserv.com  
2/20-sc  
DI-6  
WH/WIH/WIHL  
----------------------------------------------------------------------------------------------------------------------------------------------------------  
INSTALLATION  
Provide the correct counter cut-out opening and drop in. The vinyl gasket assures complete seating. A non-  
toxic silicone seal may be used between the gasket and counter top (not required). The unit is supplied  
with a power cord and NEMA plug. Refer to the data plate on the control panel for the amperage and  
voltage information. Use a licensed electrician when installing power source.  
* Control box on 14 1/4" side.  
---------------------------------------------------------------------------------------------------------------------------------------------------------  
OPERATION  
During operation the unit must be used with water and the thermostat must be set at position  
#10. The thermostat dial has an off position and is numbered 1 to 10 (Number 10 is the  
highest and mandatory setting for operation).  
--------------------------------------------------------------------------------------------------------------------------------  
MAINTENANCE  
NEVER CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER  
CLEANING COULD SCAR, MARK AND/OR CORRODE PANS. DO NOT USE STEEL WOOL OR  
ABRASIVE PRODUCTS.TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO  
REMOVE ALL RESIDUES. FAILURE TO MEET THESE CONDITIONS WILL VOID  
WARRANTY.  
--------------------------------------------------------------------------------------------------------------------------------  
Subsidiary of Mercury Aircraft, Inc.  
1135 N.W. 159th DR., MIAMI, FL 33169  
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: [email protected]  
WIH-REMOTE INSTALLATION  
PANEL WITH CUT-OUT  
WH/WIH STANDARD INSTALLATION  
STUDS  
1
3 "  
8
GALVANIZED BOX  
SCREW  
1
1
3 "  
4
4 "  
3
5 "  
4
4
DIAL  
FRONT FACE  
NUTS  
3
1 "  
INSTALLATION OF THE REMOTE CONTROL HOT UNIT8S  
.
---------------------------------------------------------------------------------------------------------------------------------------  
Provide the correct Cut-Out opening for the remote control panel (see chart below).  
Remove control box from the bottom of the unit.  
1) Remove black control dial from front of control panel by loosening screws.  
2) Remove 6/32 fiber nuts from the back of the control box.  
3) Mount the S/S front plate to the Cut-Out in apron.  
4) Attach the galvanized box to the S/S front plate.  
The unit is ready to be connected to the electrical receptacle. Refer to the data plate on the control panel for the  
amperage and voltage information. Use a licensed electrician when installing power source.  
MODEL  
CUT-OUT SIZE  
4 1/2 x 6 1/4  
4 1/2 x 12 1/4  
4 1/2 x 26  
4 1/2 x 39 3/4  
4 1/2 x 53 1/2  
4 1/2 x 67 1/4  
1
2
3
4
5
6
CAUTION: HANDLE CONTROL PANEL & CONDUIT CAREFULLY,THERMOSTAT CAPILLARY TUBE IS VERY FRAGILE, IF  
BROKEN, HEATING SYSTEM WILL NOT OPERATE.  
FAILURE TO MEET THESE CONDITIONS WILL VOID WARRANTY.  
Subsidiary of Mercury Aircraft, Inc.  
1135 N.W. 159th DR., MIAMI, FL 33169  
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: [email protected]  
PARTS LIST ELECTRICAL HEATED UNITS  
W/AUTOMATIC WATER FILL  
WH/ WIHD&M/ WIHLD&M- /WIHD&M- 1-6 SERIES  
2
1
32  
44  
46  
31  
33  
3
45  
38  
36  
35  
34  
40  
43  
4
42  
41  
37  
24  
39  
ITEM  
NUMBER  
PART  
ITEM  
NUMBER NUMBER  
PART  
DESCRIPTION  
Vinyl Bead Gasket  
Perforated Snap in Drain  
Dial  
DESCRIPTION  
NUMBER  
7002-0+Model #  
86-3202  
1097-2  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
12-228  
1022  
Plug 20Amp 240V  
Plug 30Amp 240V  
Plug 30Amp 120V  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
12-256  
1012-101  
1014-101  
1001-1  
48-22  
S84553  
51-25  
2050  
#12 Green Wire (Ground)  
#14 Green Wire (Ground)  
50 Amp Cord & Plug  
S/S 10 x 1/2 Screws  
Reservoir Assembly  
1/4" x 3/8" NPT Male Conn.  
Brass Flare Nut  
1/4" Copper Tubing  
1/4" x 1/4" Brass Union  
Dual check vacuum breaker  
#98d NPTM 1/4”  
1100  
3007-3  
3016-11  
1088-5  
1089-2  
Pilot Light  
3/4" Brass Nipple 7” long  
Brass Gate Valve  
P-136 Terminal (#22 & 18 wire)  
P-151 Terminal (#10 & 12 wire)  
P-144 Terminal (#14 & 16 wire)  
S Screw Thermostat Mounting  
Remote Thermostat with 48" Bulb  
Remote Thermostat with 72" Bulb  
12" Nickel Wire  
1089-4  
1098  
2031  
21-23  
1096-60  
1096-96  
1012-100  
1014-100  
1096-36  
S81113-2  
SC0099-238  
1053-HT  
1054-HT  
1055-HT  
1056-HT  
1057-HT  
1058-HT  
1002  
37  
600022-1  
14" Nickel Wire  
Thermostat  
Element Holder  
S/S Element Holder  
120V-850W Element  
208V-850W Element  
240V-850W Element  
120V-1000W Element  
240V-1000W Element  
208V-1000W Element  
Power Cord 14/3  
(BACK FLOW PREVENTION)  
38  
39  
30-46  
1800-3904  
1800-3903  
600002  
1800-35  
1800-39  
90º Street Elbow  
Solenoid Valve 120V  
Solenoid Valve 240V  
Brass In Line Strainer  
Ball In Valve  
Close Nipple  
90º 1/2" to 1/4 Reducing  
Elbow Brass  
1/2 dia. Brass Pipe Threaded  
Both Ends  
1/8” Male to 1/4” female  
reducer  
40  
41  
42  
43  
44  
87-69  
87-70  
24  
1004  
1004-4  
Power Cord 12/3  
Power Cord 10/3  
45  
46  
87-68  
1069-1  
Switch  
AUTOMATIC WATER FILLUNITS  
WIH, WH AND WCMHP/RMHP SERIES  
INSTALLATION  
When installing water supply to the unit, the supply lines must be purged to remove particles from  
damagingthesolenoidvalveoperation. Afactorysuppliedinlinewaterstrainerisinstalled. However, it  
is recommended the customer supply a primary water filtering system for protection.  
*NoteAtlas Metal Ind. Inc. is not responsible for routine maintenance of the strainer or customer  
supplied water filter system.  
*AtlasMetalIndustriesInc.recommendsthatallunitsinstalledtoawatersourceuseourAutofill  
or any backflow protection of your choice. Please refer to your local code.  
Any attempt to change or modify the Auto Fill system will void the warranty.  
OPERATION  
HEATING CYCLE  
HEATING TO COOLING  
1. Turn master switch to “OFF” position.  
1. Turn master switch to “OFF” position  
2. Close drain valve.  
2. Remove serving pans.  
3. Turn master switch to “ON” position.  
3. Drain hot water completely.  
4. Turn on Auto Fill.  
4. Turn selector switch to “COLD”.  
5. Fill unit, preferably with “HOT” water  
5. Turn master switch to “ON”.  
until heating element is completely  
CAUTION: Unit is equipped with a safety  
submerged (water must be level.)  
device. The compressor will not turn until  
WARNING: HEATING ELEMENT WILL  
stainless liner temperature is at 120 degrees  
BE DAMAGED IF NOT SUBMERGED AT  
or below.  
ALL TIMES DURING HEATING CYCLE!  
6. For WCMHP Select desire cooling  
6. Turn selector switch to “HOT”.  
thermostat setting (1Cool, 7Coldest).  
7. Select desired setting on heating  
For RMHP, no setup necessary; Unit  
thermostat dial (1Warm, 10Hot).  
ships with factory temperature controls  
8. Cover unit with serving pans. Unit will  
complete.  
be ready for serving in approximately  
7. Cover unit with serving pans. Unit will  
30 minutes.  
cool down and be ready for serving in  
OPERATOR MUST CHECK PERIODICALLY THAT  
approximately 30 minutes  
HEATING ELEMENT IS SUBMERGED.  
*Unit is not intended to operate 24/7.  
COOL TO HEAT  
Follow same steps shown for heat cycle  
AUTOMATIC WATER FILLUNITS  
Factory water depth settings for A/F units are 3/8" from the bottom of the liner and f  
*Note or WCMHP  
and RMHP, water depth should be 4” from the bottom of the liner.  
DO NOT manually add water to Autofill units above water level mark, damage and leakage to the  
Automatic sensor could result. As the water evaporates the pans will fill automatically.  
If the orange warning light turns on, please turn off the unit and check that the autofill is  
working properly.  
It is recommended that the Auto Fill be in the off position when not in use.  
Subsidiary of Mercury Aircraft, Inc.  
1135 N.W. 159th DR., MIAMI, FL 33169  
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: [email protected]  
Electric Hot Food Drop-In Trouble Shooting Guide  
Symptom  
Probable Cause  
Unit not plugged in.  
No power at receptacle.  
Unit will not heat  
Thermostat and or switch not in the on position.  
Call factory for service at 1-800-762-7565  
Thermostat’s not turned to the highest setting.  
Food products not hot enough when placed in unit.  
Food product not being stirred or rotated.  
Food products not  
hot enough.  
Heat lamp or head strip over the food product is recommended.  
Call factory for service at 1-800-762-7565.  
NOTE:  
Before starting any warranty repair work you must first call the factory for authorization.  
Failure to do so can make you responsible for repair cost.  
4
3
2
1
REVISION HISTORY  
DESCRIPTION  
CHANGE LABLES  
REV  
1
DATE  
2/16/2012  
B
B
1,000 OR  
850 WATTS  
ELEMENT  
1,000 OR  
850 WATTS  
ELEMENT  
G
G
T
K
W
W
L
H
A
A
B
W
2
2
1
1
WHT  
12 AWG  
RED  
GROUND TO THE  
CONTROL CASE  
BLK  
12 AWG  
BLK  
T
H
W
K
L
B
N
R
G
D
3
A
-
A
R
4
O
1
C
POWER  
CORD  
MATERIAL:  
CATEGORY:  
DRAWN BY:  
DATE:  
11/30/2010  
L.AND  
TOLERANCES  
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169  
CHECKED BY: ----  
BREAK ALL SHARP  
DESCRIPTION:  
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,  
IMAGES AND TRADE SECRETS OF ATLAS  
METALS, INC. ANY UNAUTHORIZED USE OR  
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY  
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY  
OF ATLAS METALS INDUSTRIES, INC.  
ELECTRICAL SCHEMATIC  
CORNERS.  
PART TO BE FREE OF  
BURRS.  
XXX DECIMAL 0.015  
SIZE:  
PART NUMBER:  
WH-2 120V  
ANGULARITY  
1
B
UNLESS SPECIFIED  
ON DRAWING  
UNLESS OTHERWISE SPECIFIED,  
ALL DIMENSIONS ARE IN INCHES  
ALL RIGHTS RESERVED.  
SHEET No.  
SCALE: ----  
1 OF 1  
1
4
3
2
4
3
2
1
REVISION HISTORY  
DESCRIPTION  
CHANGE LABLES  
REV  
1
DATE  
2/16/2012  
B
B
1,000 OR  
850 WATTS  
ELEMENT  
1,000 OR  
850 WATTS  
ELEMENT  
G
G
K
W
D
W
L
A
E
A
B
R
2
2
1
1
RED  
12 AWG  
RED  
GROUND TO THE  
CONTROL CASE  
BLK  
12 AWG  
BLK  
T
H
W
K
L
B
N
R
G
D
3
-
A
R
A
4
O
1
C
POWER  
CORD  
MATERIAL:  
CATEGORY:  
DRAWN BY:  
DATE:  
11/30/2010  
L.AND  
TOLERANCES  
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169  
DESCRIPTION:  
CHECKED BY: ----  
BREAK ALL SHARP  
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,  
IMAGES AND TRADE SECRETS OF ATLAS  
METALS, INC. ANY UNAUTHORIZED USE OR  
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY  
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY  
OF ATLAS METALS INDUSTRIES, INC.  
ELECTRICAL SCHEMATIC  
CORNERS.  
PART TO BE FREE OF  
BURRS.  
XXX DECIMAL 0.015  
SIZE:  
PART NUMBER:  
WH-2 208-240V  
ANGULARITY  
1
B
UNLESS SPECIFIED  
ON DRAWING  
UNLESS OTHERWISE SPECIFIED,  
ALL DIMENSIONS ARE IN INCHES  
ALL RIGHTS RESERVED.  
SHEET No.  
SCALE: ----  
1 OF 1  
1
4
3
2
4
3
2
1
REVISION HISTORY  
DESCRIPTION  
CHANGE LABLES  
REV  
1
DATE  
2/16/2012  
B
B
1,000 OR  
850 WATTS  
ELEMENT  
1,000 OR  
850 WATTS  
ELEMENT  
G
G
G
G
T
W
K
W
T
W
K
W
H
L
A
A
H
L
A
A
B
W
B
4
4
W
4
4
1
1
1
1
WHT  
12 AWG  
RED  
RED  
GROUND TO THE  
CONTROL CASE  
BLK  
12 AWG  
BLK  
BLK  
T
H
W
K
L
B
N
R
G
D
3
-
R
A
A
4
O
1
C
POWER  
CORD  
MATERIAL:  
CATEGORY:  
DRAWN BY:  
DATE:  
11/30/2010  
L.AND  
TOLERANCES  
WIH  
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169  
DESCRIPTION:  
CHECKED BY: ----  
BREAK ALL SHARP  
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,  
IMAGES AND TRADE SECRETS OF ATLAS  
METALS, INC. ANY UNAUTHORIZED USE OR  
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY  
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY  
OF ATLAS METALS INDUSTRIES, INC.  
ELECTRICAL SCHEMATIC  
CORNERS.  
PART TO BE FREE OF  
BURRS.  
XXX DECIMAL 0.015  
SIZE:  
PART NUMBER:  
WIH-2 120V  
ANGULARITY  
1
B
UNLESS SPECIFIED  
ON DRAWING  
UNLESS OTHERWISE SPECIFIED,  
ALL DIMENSIONS ARE IN INCHES  
ALL RIGHTS RESERVED.  
SHEET No.  
SCALE: ----  
1 OF 1  
4
1
3
2
4
3
2
1
REVISION HISTORY  
DESCRIPTION  
CHANGE LABLES  
REV  
1
DATE  
2/16/2012  
B
B
1,000 OR  
850 WATTS  
ELEMENT  
1,000 OR  
850 WATTS  
ELEMENT  
G
G
G
G
K
W
D
W
K
W
D
W
L
A
E
A
L
A
E
A
B
R
B
4
R
4
4
4
1
1
1
1
RED  
12 AWG  
RED  
RED  
GROUND TO THE  
CONTROL CASE  
BLK  
12 AWG  
BLK  
BLK  
T
H
W
K
L
B
N
R
G
D
3
-
R
A
A
4
O
1
C
POWER  
CORD  
MATERIAL:  
CATEGORY:  
DRAWN BY:  
DATE:  
11/30/2010  
L.AND  
TOLERANCES  
WIH  
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169  
DESCRIPTION:  
CHECKED BY: ----  
BREAK ALL SHARP  
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,  
IMAGES AND TRADE SECRETS OF ATLAS  
METALS, INC. ANY UNAUTHORIZED USE OR  
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY  
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY  
OF ATLAS METALS INDUSTRIES, INC.  
ELECTRICAL SCHEMATIC  
CORNERS.  
PART TO BE FREE OF  
BURRS.  
XXX DECIMAL 0.015  
SIZE:  
PART NUMBER:  
WIH-2 208-240V  
ANGULARITY  
1
B
UNLESS SPECIFIED  
ON DRAWING  
UNLESS OTHERWISE SPECIFIED,  
ALL DIMENSIONS ARE IN INCHES  
ALL RIGHTS RESERVED.  
SHEET No.  
SCALE: ----  
1 OF 1  
1
4
3
2
LIMITED WARRANTY  
Atlas Metal Industries, Inc. warrants to the Purchaser of this product that the  
same shall be free from defects in the workmanship and material for a period of  
one year from the date of original installation of the equipment, but not to exceed  
eighteen (18) months after date of shipment from factory. During this period of  
time Atlas Metal Industries, Inc. will replace all defective parts and will pay for  
authorized replacement labor. Replacement and installation of such parts and  
labor shall be provided only upon prior written authority of Atlas Metal Industries,  
Inc.  
The Refrigeration warranty is for a twenty (20) month time period and includes  
supplying the compressor at a no charge basis provided the damage to the  
compressor was not caused by the customer or end user. Authorized  
replacement labor will be paid for a period of one year from date of installation.  
Freight costs for defective unit to and from Atlas Metal Industries, Inc. are not  
included, and all defective parts must be returned to the factory freight prepaid  
for evaluation. ALL WARRANTY LABOR MUST BE AUTHORIZED BY ATLAS  
METAL INDUSTRIES, INC. PRIOR TO THE ACTUAL WORK BEING DONE.  
This warranty does not apply to any equipment or any part thereof, which has  
been subjected to shipping damage, improper voltage, alteration, abuse or  
misuses, and does not cover loss of food, other products, or damage to property  
due to mechanical or electrical malfunction.  
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE  
DESCRIPTION OF THE FACE HEREOF. SELLER DISCLAIMS ANY IMPLIED  
WARRANTY OF MERCHANTABILITY OF THE GOODS OR THE FITNESS OF  
THE GOODS FOR ANY PURPOSE AND BUYER AGREES THAT THE GOODS  
ARE SOLD “AS IS.”  
WARRANTY INFORMATION  
In order to have your invoice approved for  
payment by the factory, please note the following:  
_______________________________________________  
An authorization number must be obtained from  
the factory prior to performing any warranty  
service.  
_______________________________________________  
Atlas Metal will not approve excessive labor due to poor  
access to the unit being serviced. If design does not  
allow reasonable access, contact the factory.  
_______________________________________________  
All travel time that exceeds 100 miles round trip  
must be authorized by the factory.  
_____________________________________________________________________________________  
Thank You:  
Warranty service Dept.  

Subaru Robin Power Products Automobile Parts Pub Ep User Manual
Ricoh Pro C900s User Manual
Radio Shack Tad 277 User Manual
Panasonic Kx Tg5632m Kx Tg5632m User Manual
LEXMARK X1150 User Manual
KENWOOD KRC V679R User Manual
KENWOOD KMC5XX 02 User Manual
EPSON EB 84H User Manual
ASUS ZENFONE GO X014D ZB452KG User Manual
ASUS VE249 User Manual