ATLAS METAL WCM BT 6 User Manual

COLD PAN REFRIGERATED AIR FLOW SYSTEM  
WCM-BT SERIES  
Service and Installation Manual  
Please read this manual completely before attempting to install or operate this equipment!  
Notify carrier of damage! Inspect all components immediately. See page 1.  
DROP-IN COLD PAN  
REFRIGERATED, AIR FLOW SYSTEM  
SELF-CONTAINED WITH DEFROST SYSTEM  
Effective Date: 2019  
IMPORTANT INFORMATION  
READ BEFORE USE  
Project: ___________  
Item No.:ꢀ ___________  
Quantity:ꢀ ___________  
DROP-IN SERVING EQUIPMENT  
COLD PAN  
WCM-BT-3  
WCM-BT-4  
WCM-BT-5  
WCM-BT-6  
Refrigerated  
Air Flow System  
Self-Contained with  
Defrost System  
WCM-BT-4  
SPECIFICATIONS  
STANDARD FEATURES  
TOP: Constructed of 18 gauge, type 304 stainless steel, die  
stamped with a raised perimeter bead. There shall be a solid  
vinyl gasket under the beaded edge to form a seal to the  
counter top, thus preventing seepage or marring of the  
counter top. Embossed mounting lugs are provided along the  
inner surface of the top to hold a full set of removable  
separator channels in place.  
g
Forced air evaporator blower system for maximum  
efficiency in cooling - more consistent food product  
temperature  
g
g
Automatic Defrost System  
Fully insulated for maximum efficiency and energy  
savings  
g Factory applied gasket - makes installation a snap and  
seals units to the counter top, thus eliminating  
seepage  
g Accommodates standard 12”ꢀX 20”ꢀpans with the use  
of separator channel(s), or fractional size pans with the  
use of optional adapter bars  
LINER: The inner liner shall be 18 gauge, type 304 stainless  
steel, one piece construction, all welded, ground and polished  
to a uniform finish. All corners are coved with a minimum 1/4"  
radius.  
INSULATION: The pan is fully insulated with high density  
polystyrene, 1" thick on all sides, 2" thick on the bottom and  
enclosed with a 22 gauge galvanized steel outer case.  
g
1-Year Parts & Labor Warranty  
UL Listed  
g
REFRIGERATION SYSTEM: The compressor housing shall  
be fabricated from 14 gauge galvanized and bolted to the  
base of the unit. A fully self-contained condensing unit is pro-  
vided with a hermetically sealed compressor and a thermostat  
control. The system is also provided with a forced air evapora-  
tor for even temperature throughout the pan that drains into a  
condensate evaporator pre-wired in the unit. Automatic defrost  
system is provided. The system is fully charged with CFC free  
refrigerant and ready to operate.  
ACCESSORIES  
g
5YW - 5-Year Compressor Warranty  
g Stainless Steel adapter bars (pg DI-51-52)  
g Stainless Steel adapter plates (pg DI-51-52)  
g
CP - Cover Plate with handles, S/S  
g
RS - Remote on/off switch for counter mounting  
g * 220 Volt - 50 Cycle Compressor  
NOTE: Proper ventilation must be provided in counter.  
ELECTRICAL: The unit will be wired for 15 amps., 120 volt,  
single phase operation with an on/off thermostat switch and  
pilot light. A 6' long, 3-wire cord and plug (NEMA 5-15P) will  
be provided.  
Specifications subject to change without notice.  
*Please see Operation &ꢀInstallation Manual for ALL operation and maintenance details.  
* Units with these accessories are not currently ULꢀlisted.  
DI-27  
REMOVABLE SEPARATOR  
CHANNELS  
A
4”  
6”  
8”  
14”  
16”  
24”  
20-1/8”  
10-3/4”  
B
21-1/2”  
21-5/8”  
4-7/8”  
PLAN VIEW  
ELEVATION  
END VIEW  
EVAPORATOR  
ELECTRICAL  
CHARACTERISTICS  
6.8 amps. - 120V - 22-1/4” X 41-3/4”  
1/4HP  
CUT-OUT  
SHIP WT.  
(LBS.)  
MODEL  
“A”  
“B”  
PAN SIZE  
REMOTE  
LESS COMP.  
REQUIRED  
REFRIGERATION SHIP WT.  
43-1/2”  
6”  
19-7/8” X 39-1/4 X 14”  
228  
MODEL  
(LBS.)  
WCM-BT-3  
WCM-BT-4  
WCM-BT-5  
(110.4cm) (15.24cm) (50.4 X 99.6 X 35.5cm)  
(56.5 X 106cm) (103.4kg)  
180  
(81.6kg)  
222  
WCM-BTX-3  
57-1/4”  
4-1/8”  
19-7/8”ꢀX 53” X 14”  
9.2 amps. - 120V - 22-1/4” X 55-1/2”  
268  
(145.4cm) (10.5cm) (50.4 X 134.6 X 35.5cm)  
1/3HP (56.5 X 140.9cm) (121.5kg)  
WCM-BTX-4  
WCM-BTX-5  
(100.6kg)  
259  
(117.4kg)  
71” 7”  
(180.3cm) (17.78cm) (50.4 X 169.5 X 35.5cm)  
19-7/8” X 66-3/4” X 14” 9.2 amps. - 120V - 22-1/4” X 69-1/4”  
311  
1/3HP  
(56.5 X 175.8cm) (141.1kg)  
299  
(135.6kg)  
84-3/4” 7” 19-7/8” X 80-1/2” X 14” 9.2 amps. - 120V -  
(215.2cm) (17.78cm) (50.4 X 204.4 X 35.5cm) 1/3HP  
22-1/4” X 83”  
345  
WCM-BTX-6  
WCM-BT-6  
(56.5 X 210.8cm) (156.4kg)  
REFRIGERATION CHART  
LOW  
PSIG.  
10  
HIGH  
BTU  
MODEL  
HP  
REF. OZ.  
PSIG. M10 90A  
WCM-BT-3 1/4  
WCM-BT-4 1/3  
WCM-BT-5 1/3  
WCM-BT-6 1/3  
134A  
134A  
134A  
134A  
8
170  
190  
160  
125  
1070  
1285  
1285  
1285  
10  
10  
10  
9
9
9
WCM-BTX - REFRIGERATED COLD PAN WITHOUT  
COMPRESSOR  
COMPRESSORS FOR REMOTE INSTALLATIONS  
Units include Refrigerated Cold Pan,  
Thermostat, Cap Tube & Drier  
2029-17JP - 1/4 HP for WCM-BTX-3  
2029-27JL - 1/3 HPꢀfor WCM-BTX-4, 5 & 6  
(for hook up in field by others)  
Atlas Metal Industries 1135 NWꢀ159th Dr. Miami, FL 33169 (800) 762-7565 Fax: (305) 623-0475 atlasfoodserv.com  
6/19-sc  
DI-28  
REFRIGERATED PAN WITH EVAPORATOR  
BLOWER & TIMER  
WCMBT SERIES  
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
INSTALLATION  
Provide the correct counter cut-out opening (see chart below) and drop in. The vinyl gasket assures complete seating. A  
non-toxic silicone seal may be used between the gasket and counter top (not required).  
NOTE: Units are supplied with the nipple PVC and pipe connected to condensing evaporator.  
MODEL NUMBER  
CUT-OUT SIZE  
WCMBT-3  
WCMBT-4  
WCMBT-5  
WCMBT-6  
22 1/4 X 41 3/4  
22 1/4 X 55 1/2  
22 1/4 X 69 1/4  
22 1/4 X 83  
The unit should be level for draining purposes. When installing unit in a counter, it is recommended that the operator  
side of the counter be completely open for air circulation. When this is not possible, such as in an island counter, it is  
recommended that two grill openings are provided approximately 18” x 18” of free air for intake and exhaust at the  
opposite ends of the counter.  
The unit is supplied with a power cord and NEMA plug. Refer to the data plate on the compressor housing for the  
amperage and voltage information. Use a licensed electrician when installing power source.  
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
OPERATION  
The unit should be turned on one hour before serving and turned off after completing the serving period. If the  
compressor does not start immediately there is a chance the unit is in a defrost mode. A timer is installed to shut down  
the compressor for defrosting every 8 hour for 15 minutes. For maximum efficiency, empty food pans or covers must  
be in the openings until unit is ready for product. Do not block discharge or intake openings inside the unit.  
The thermostat has an off position and numbers from #1 through #7 (number 7 is the coldest). The unit should be  
turned off every day after used. Note: The unit should not operate 24/7.  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
MAINTENANCE  
NEVER CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER CLEANING  
COULD SCAR, MARK AND/OR CORRODE PANS. DO NOT USE STEEL WOOL OR ABRASIVE PRODUCTS.  
TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE ALL RESIDUES. FAILURE  
TO MEET THESE CONDITIONS WILL VOID WARRANTY.  
CLEAN CONDENSER COIL REGULARLY.  
Subsidiary of Mercury Aircraft, Inc.  
1135 N.W. 159th DR., MIAMI, FL 33169  
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: [email protected]  
PARTS LIST REFRIGERATED PAN WITH BLOWER & TIMER  
WCMBT SERIES  
1
10  
8
2
3
4
5
W CM BT-5 SH O W N  
DESCRIPTION  
7
6
ITEM  
NUMBER  
PART  
NUMBER  
S80103-0  
7002-0+Model  
7020-0  
1
2
3
4
5
6
Separator Channel  
Vinyl Bead Gasket  
Nylon Spacer  
2060-1  
1003-0  
1069-1  
Condensing Water Evaporator  
Power Cord with Plug  
Switch with Light  
2029-17JP  
2029-27JL  
S11855-0  
S81857-0  
2014-5  
1/4 H.P. Compressor WCMBT-3  
1/3 H.P. Compressor WCMBT-4, 5, 6  
Blower Housing Assembly WCMBT-3  
Blower Housing Assembly WCMBT-4, 5, 6  
Fan Blade (Not Shown)  
7
8
9
10  
11  
12  
13  
S81443-0  
2013-0  
S11857-0  
S81862-0  
2119-3  
Fan Guard  
Fan Motor (Not Shown)  
Drain Pan WCMBT-3 (Not Shown)  
Drain Pan WCMBT-4, 5, 6 (Not Shown)  
Evaporator Coil WCMBT-3 (Not Shown)  
Evaporator Coil WCMBT-4, 5, 6 (Not Shown)  
Defrost Thermostat (Not Shown)  
Timer (Not shown)  
Heating Element WCMBT-3 (Not Shown)  
Heating Element WCMBT-4, 5, 6 (Not Shown)  
0.042 Cap Tube (Not Shown)  
Harness (Not Shown)  
12  
2119-1  
13  
14  
22-1399  
20-3010  
111-1080  
111-1071  
2026-0  
1150  
2025-0  
2044-0  
15  
16  
17  
18  
19  
Drier (Not Shown)  
Thermostat (Not Shown)  
REFRIGERATED PAN WITH EVAPORATOR  
BLOWER & TIMER  
WCMBT SERIES  
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
INSTALLATION  
Provide the correct counter cut-out opening (see chart below) and drop in. The vinyl gasket assures complete seating. A  
non-toxic silicone seal may be used between the gasket and counter top (not required).  
NOTE: Units are supplied with the nipple PVC and pipe connected to condensing evaporator.  
MODEL NUMBER  
CUT-OUT SIZE  
WCMBT-3  
WCMBT-4  
WCMBT-5  
WCMBT-6  
22 1/4 X 41 3/4  
22 1/4 X 55 1/2  
22 1/4 X 69 1/4  
22 1/4 X 83  
The unit should be level for draining purposes. When installing unit in a counter, it is recommended that the operator  
side of the counter be completely open for air circulation. When this is not possible, such as in an island counter, it is  
recommended that two grill openings are provided approximately 18” x 18” of free air for intake and exhaust at the  
opposite ends of the counter.  
The unit is supplied with a power cord and NEMA plug. Refer to the data plate on the compressor housing for the  
amperage and voltage information. Use a licensed electrician when installing power source.  
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
OPERATION  
The unit should be turned on one hour before serving and turned off after completing the serving period. If the  
compressor does not start immediately there is a chance the unit is in a defrost mode. A timer is installed to shut down  
the compressor for defrosting every 8 hour for 15 minutes. For maximum efficiency, empty food pans or covers must  
be in the openings until unit is ready for product. Do not block discharge or intake openings inside the unit.  
The thermostat has an off position and numbers from #1 through #7 (number 7 is the coldest). The unit should be  
turned off every day after used. Note: The unit should not operate 24/7.  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
MAINTENANCE  
NEVER CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER CLEANING  
COULD SCAR, MARK AND/OR CORRODE PANS. DO NOT USE STEEL WOOL OR ABRASIVE PRODUCTS.  
TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE ALL RESIDUES. FAILURE  
TO MEET THESE CONDITIONS WILL VOID WARRANTY.  
CLEAN CONDENSER COIL REGULARLY.  
Subsidiaꢀ of Meꢁuꢀ Aꢂꢃꢄ, Inc.  
1135 N.W. 159th DR., MIAMI, FL 33169  
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: sales@atlasfoodseꢀ.com  
Reꢀigerated Drop-In Trouble Shooting Guide  
Symptom  
Probable Cause  
Unit not plugged in.  
No power at receptacle.  
Unit will not run  
Thermostat and or switch not in the on position.  
Unit may be in a deꢀost cycle (ifsupplied) wait approximately 20 min.  
Call ꢁctory ꢂr service at 1-800-762-7565  
Condenser coil dirty  
Inadequate ventilation.  
Call ꢁctory ꢂr service at 1-800-762-7565  
Condenser coil dirty.  
Condenser runs but  
short cycles  
Inadequate ventilation.  
Unit installed in a hot location  
Condenser runs  
constantly.  
Call ꢁctory ꢂr service at 1-800-762-7565  
NOTE: WF series runs constantly.  
Food product must be chilled to 33-35 deg. when placed in unit.  
Air movement over ꢂod proꢃct.  
Food product not being stirred or rotated.  
Call ꢁctory ꢂr service at 1-800-762-7565  
Food product not  
cold enough.  
4
3
2
1
B
B
A
A
REVISION HISTORY  
DESCRIPTION  
DATE:  
09.17.08  
SIwE:  
B
CrSTOMER:  
REcERENCE:  
ThHVH SOD V DrH thH H cO ViYH SroSHrt  
REV  
1
2
3
4
DATE  
BY  
tCMBT EiECTRICAi SCHEMATIC  
tCMBT 3-4-5-6  
oI AtODV MHtDO I d VtriHV I c. A  
D thori Hd  
DRAtN BY:  
MHA  
VH w itho t w rittH co VH t oI AtODV  
MHtDO I d VtriHV I c., iV VtrictO SrohiEitHd.  
CHEChED BY:  
NS  
P.O. #:  
JOB #:  
DRAtINd No.  
-----  
------  
------  
SCAiE: 3/4" = 1'-0"  
SHEET No. 1 Oc 1  
1135 Nt 159TH DRIVE MIAMI, ciORIDA 33169  
5
4
3
2
1
LIMITED WARRANTY  
Atlas Metal Industries, Inc. warrants to the Purchaser of this product that the  
same shall be free from defects in the workmanship and material for a period of  
one year from the date of original installation of the equipment, but not to exceed  
eighteen (18) months after date of shipment from factory. During this period of  
time Atlas Metal Industries, Inc. will replace all defective parts and will pay for  
authorized replacement labor. Replacement and installation of such parts and  
labor shall be provided only upon prior written authority of Atlas Metal Industries,  
Inc.  
The Refrigeration warranty is for a twenty (20) month time period and includes  
supplying the compressor at a no charge basis provided the damage to the  
compressor was not caused by the customer or end user. Authorized  
replacement labor will be paid for a period of one year from date of installation.  
Freight costs for defective unit to and from Atlas Metal Industries, Inc. are not  
included, and all defective parts must be returned to the factory freight prepaid  
for evaluation. ALL WARRANTY LABOR MUST BE AUTHORIZED BY ATLAS  
METAL INDUSTRIES, INC. PRIOR TO THE ACTUAL WORK BEING DONE.  
This warranty does not apply to any equipment or any part thereof, which has  
been subjected to shipping damage, improper voltage, alteration, abuse or  
misuses, and does not cover loss of food, other products, or damage to property  
due to mechanical or electrical malfunction.  
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE  
DESCRIPTION OF THE FACE HEREOF. SELLER DISCLAIMS ANY IMPLIED  
WARRANTY OF MERCHANTABILITY OF THE GOODS OR THE FITNESS OF  
THE GOODS FOR ANY PURPOSE AND BUYER AGREES THAT THE GOODS  
ARE SOLD “AS IS.”  
WARRANTY INFORMATION  
In order to have your invoice approved for  
payment by the factory, please note the following:  
_______________________________________________  
An authorization number must be obtained from  
the factory prior to performing any warranty  
service.  
_______________________________________________  
Atlas Metal will not approve excessive labor due to poor  
access to the unit being serviced. If design does not  
allow reasonable access, contact the factory.  
_______________________________________________  
All travel time that exceeds 100 miles round trip  
must be authorized by the factory.  
_____________________________________________________________________________________  
Thank You:  
Warranty service Dept.  

Soleus Air Ky 80g User Manual
Sanyo Cr2016 User Manual
Powerdsine Lx2206 User Manual
Philips R03b4a90 User Manual
MAKITA LS0714 User Manual
KENWOOD NX 1300A 02 User Manual
John Deere D125 User Manual
DELL DJ DITTY HV04T User Manual
CYBERPOWER PDU41105 User Manual
CRAFTSMAN 28980 User Manual