| 255427-YTG-F-1006   DESCRIPTION   This unique modular system allows the flexibility to handle any   application. These versatile coils and blowers may be used for   upflow, downflow, or horizontal left or right applications. They   may be combined to function as a cooling only unit or with a heat   pump including electric heat for 1 and 3 phase applications. The   blower and electric heater could be used as stand alone electric   furnaces.   FEATURES   TECHNICAL GUIDE   BLOWERS - Models to match any air flow or voltage require-   ment. The compact size allows easy installation. Blowers are   sized to deliver design air quantity both efficiently and quietly.   The motors provide a selection of air quantities to match any   application. All models include a one-minute blower off delay as   standard to enhance system efficiency ratings. The durable, pre-   painted steel protects the unit against rust and corrosion. All   models have 1 inch foil face fiber glass insulation, providing a   thermal insulation value of R-4.2.   MODELS: MV   MODULAR VARIABLE SPEED AIR HANDLERS   FOR USE WITH SPLIT SYSTEM   COOLING & HEAT PUMP   1200 - 2000 CFM BLOWERS   3 - 5 TON COILS   COILS - Staggered rows of rifled copper tubes are mechanically   expanded into enhanced surface aluminum fins to provide high   heat transfer and long-lasting quality. The MC multi-position   coils may be used for upflow, downflow, and horizontal left or   right applications. Coil cabinets are insulated with 3/4" foil face   insulation to prevent sweating.   OPTIONAL 1 & 3φ ELECTRIC HEATERS   ELECTRIC HEATERS - Both single and three phase electric   heater models are available to match any requirement. All heat-   ers include nickel-chromium elements with a 5-year limited war-   ranty on 1 Ø heating elements and 1 year limited warranty on 3   Ø heating elements. Sequential operation is provided to control   heaters in all models. Circuit breakers are used in 208/230 volt,   single-phase heaters of 15 KW and larger.   Models equipped with circuit breakers may be altered in the field   to use multi-source power supply. Over-temperature limit   switches provide protection from airflow loss with fusible link   backup protection.   ACCESSORIES - A full line of matching accessories available   for use with the blower and coils to allow any type application.   LIMITATIONS - These units must be wired and installed in   accordance with all national and local safety codes.   Voltage limits are as follows:   NORMAL OPERATING   AIR HANDLER VOLTAGE   VOLTAGE RANGE*   208/230-1-60   187 - 253   * Rated in accordance with ARI Standard 110, utilization range “A”.   Air flow must be within the minimum and maximum limits approved for electric   heat, evaporator coils and outdoor units.   ISO 9001   Certified Quality   Management System   Due to continuous product improvement, specifications   subject to change without notice.   Additional rating information can be found at   FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE   255427-YTG-F-1006   COOLING CAPACITY - COIL ONLY   MBH @ Evaporator Temperature and   Corresponding Pressure °F / PSIG   Blower   Model   Coil   Model   Rated   CFM   Entering Air °F   (Dry / Wet Bulb)   35 / 61.5   40 / 68.5   45 / 76.0   50 / 84.0   Multi-Position - Upflow / Downflow / Horizontal   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   85 / 72   80 / 67   75 / 62   70 / 57   41.5   36.2   29.1   24.1   52.0   41.7   32.5   27.9   46.8   37.4   28.9   25.1   53.7   43.0   33.1   28.8   91.7   73.4   57.3   49.2   88.4   70.8   55.2   47.4   100.5   80.4   62.7   53.9   119.9   96.0   74.0   64.3   124.8   99.9   77   37.8   32.4   25.3   21.5   47.3   36.8   27.3   25.8   42.4   33.3   24.6   23.3   48.4   38.0   28.1   26.5   78.4   61.5   45.6   43.0   76.0   59.4   43.9   41.5   86.4   67.5   49.9   47.2   101.0   79.2   58.6   55.4   105.2   82.5   61.1   57.7   110.5   86.6   64.2   60.6   33.7   28.6   24.0   18.7   42.3   32.3   29.8   23.8   37.6   29.4   21.7   21.7   43.5   33.3   24.5   24.5   68.1   52.0   38.4   38.4   63.3   48.4   35.8   35.8   72.0   55.0   40.7   40.7   80.0   62.6   46.2   46.2   85.3   65.2   48.1   48.1   89.6   68.5   50.5   50.5   29.5   24.5   19.2   15.8   37.3   27.4   22.2   22.2   33.0   24.3   19.6   19.6   37.5   27.7   22.4   22.4   52.3   38.6   31.2   31.2   50.0   37.0   29.9   29.9   56.8   42.1   34.0   34.0   62.2   45.8   37.0   37   MC30B**H   MC36B**H   MC48D**H   MC60D**H   MC61D**H   MC42C**H   MC48C**H   MC48D**H   MC60D**H   MC61D**H   1025   1250   1125   1275   1450   1400   1650   1725   2000   2200   MV12B   MV12D   MV16C   MV20D   64.7   47.7   38.6   38.6   67.9   50.1   40.5   40.5   66.9   131.0   104.9   81.8   70.2   Unitary Products Group   3 255427-YTG-F-1006   PHYSICAL & ELECTRICAL DATA   Model   MV12B   10 x 7   1/2   MV12D   10 x 10   1/2   MV16C   10 x 10   3/4   MV20D   10 x 10   1 Blower - Diameter x Width   HP   Motor   Nominal RPM   1200   1200   1200   1200   Voltage   208/230   Amps   Full Load (230)   Type   4.3   4.3   5.0   7.0   DISPOSABLE OR PERMANENT   Filter   Size   16 x 20 x 1   1PF0601BK   1FR0717   68 / 62   22 x 20 x 1   1PF0603BK   1FR0724   88 / 82   20 x 20 x 1   1PF0602BK   1FR0721   75 / 69   22 x 20 x 1   1PF0603BK   1FR0724   93 / 87   Permanent Type Kit   Filter Rack   Shipping / Operating Weight (lbs.)   COILS   Refrig.   Application Conn.   Types   Face   Fin   Per   In.   Operating   Weight   (Lbs.)   Rows   Deep   Tube   Geometry   Tube   Dia.   Fin   Type   Model   Area   Coil Size   TXV   (Sq. Ft.)   MC18A3XH1   MC18A2AH1   MC18B3XH1   MC18B2AH1   MC24A3XH1   MC24A2AH1   MC24B3XH1   MC24B2AH1   MC30A3XH1   MC30A2AH1   MC30B3XH1   MC30B2AH1   MC35B3XH1   MC35C3XH1   MC36A3XH1   MC36A2AH1   MC36B3XH1   MC36B2AH1   MC36C3XH1   MC36C2AH1   MC42B3XH1   MC42B2CH1   MC42C3XH1   MC42C2CH1   MC48C3XH1   MC48C2CH1   MC48D3XH1   MC48D2CH1   MC60D3XH1   MC60D2CH1   MC61D3XH1   MC61D2CH1   None   2A   3.40   3.40   4.38   4.38   4.38   4.38   3.90   4.86   4.86   4.86   5.83   5.83   5.35   5.35   5.83   6.80   2 14   14   14   14   14   14   12   14   14   14   14   14   12   12   12   12   (2) 14 x 17.5   (2) 14 x 17.5   (2) 18 x 17.5   (2) 18 x 17.5   (2) 18 x 17.5   (2) 18 x 17.5   (2) 16 x 17.5   (2) 20 x 17.5   (2) 20 x 17.5   (2) 20 x 17.5   (2) 24 x 17.5   (2) 24 x 17.5   (2) 22 x 17.5   (2) 22 x 17.5   (2) 24 x 17.5   (2) 28 x 17.5   53   53   56   56   56   56   65   64   65   65   72   72   82   82   86   98   None   2A   2 2 2 2 2 3 2 2 2 2 2 3 3 3 3 None   2A   None   2A   None   2A   None   2A   None   None   None   2A   Cooling /   Sweat   1 x 0.866   3/8   Enhanced   Heat Pump   None   2A   None   2A   None   2C   None   2C   None   2C   None   2C   None   2C   None   2C   4 Unitary Products Group   255427-YTG-F-1006   ELECTRICAL DATA - 208/230-1-60   Max.   Total Heat1   MBH   208V 240V 208V 240V   KW Staging   W2 Only   Min.   Speed   Tap   Model   Heater Model*   KW   W1 Only   208V   W1 + W2   208V 240V   Static   240V   4.8   3.75   4.8   4.8   4.8   3.75   4.8   4.8   4.4   4.8   4.8   3.75   4.8   4.8   4.4   4.8   4.8   4.8   4.4   4.8   4.8   208V   3.6   5.6   7.2   7.2   3.6   5.6   7.2   7.2   6.6   7.2   3.6   5.6   7.2   7.2   6.6   7.2   7.2   7.2   6.6   7.2   10.8   240V   4HK*6500506   4HK*6500806   4HK*6501006   4HK165N1506   4HK*6500506   4HK*6500806   4HK*6501006   4HK16501506   4HK16501806   4HK16502006   4HK*6500506   4HK*6500806   4HK*6501006   4HK16501506   4HK16501806   4HK16502006   4HK*6501006   4HK16501506   4HK16501806   4HK16502006   4HK16502506   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   Heat-D   3.6   5.6   7.2   4.8   7.5   9.6   12.3   19.2   24.6   16.4   25.6   32.8   49.1   16.4   25.6   32.8   49.1   60.1   65.5   16.4   25.6   32.8   49.1   60.1   65.5   32.8   49.1   60.1   65.5   81.9   3.6   2.8   3.6   3.6   3.6   2.8   3.6   3.6   3.3   3.6   3.6   2.8   3.6   3.6   3.3   3.6   3.6   3.6   3.3   3.6   3.6   4.8   7.5   9.6   9.6   4.8   7.5   9.6   9.6   8.8   9.6   4.8   7.5   9.6   9.6   8.8   9.6   9.6   9.6   8.8   9.6   14.4   3.6   5.6   4.8   7.5   MV12B   7.2   9.6   10.8 14.4 36.9   10.8   3.6   14.4   4.8   3.6   5.6   7.2   4.8   7.5   9.6   12.3   19.2   24.6   5.6   7.5   7.2   9.6   MV12D   10.8 14.4 36.9   13.2 17.6 45.1   14.4 19.2 49.2   10.8   13.2   14.4   3.6   14.4   17.6   19.2   4.8   3.6   5.6   7.2   4.8   7.5   9.6   12.3   19.2   24.6   5.6   7.5   7.2   9.6   MV16C   MV20D   10.8 14.4 36.9   13.2 17.6 45.1   14.4 19.2 49.2   10.8   13.2   14.4   7.2   14.4   17.6   19.2   9.6   7.2   9.6   24.6   10.8 14.4 36.9   13.2 17.6 45.1   14.4 19.2 49.2   18.0 24.0 61.5   10.8   13.2   14.4   18.0   14.4   17.6   19.2   24   1. See conversion table on Page 7.   May be 0 (no breaker) or 1 (with breaker).   * ELECTRICAL DATA - 208/230-3-60   Total Heat1   MBH   KW Staging   W2 Only   Min.   Speed   Tap   Heat Kit -   Models   Max.   Static   KW   W1 Only   W1 + W2   Three Phase   208V 240V 208V 240V 208V 240V 208V 240V 208V 240V   MV12BN21   MV12DN21   4HK06501025   4HK06501025   4HK06501525   4HK06501825   4HK06501025   4HK06501525   4HK06501825   4HK06501025   4HK06501525   4HK16502525   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   0.5   Heat-D   Heat-D   7.2   7.2   9.6   9.6   24.6   24.6   36.9   44.7   24.6   36.9   44.7   24.6   36.9   61.4   32.8   32.8   49.1   58.7   32.8   49.1   58.7   32.8   49.1   81.4   7.2   7.2   9.6   9.6   7.2   7.2   9.6   9.6   7.2   7.2   9.6   9.6   Heat-D 10.8   Heat-D 12.9   14.4   17.2   9.6   10.8   12.9   7.2   14.4   17.2   9.6   10.8   12.9   7.2   14.4   17.2   9.6   10.8   12.9   7.2   14.4   17.2   9.6   Heat-D   7.2   MV16CN21   MV20DN21   Heat-D 10.8   Heat-D 12.9   14.4   17.2   9.6   10.8   12.9   7.2   14.4   17.2   9.6   10.8   12.9   7.2   14.4   17.2   9.6   10.8   12.9   7.2   14.4   17.2   9.6   Heat-D   7.2   Heat-D 10.8   Heat-D 18.0   14.4   24.0   10.8   9.0   14.4   12.0   10.8   18.0   14.4   24.0   10.8   18.0   14.4   24.0   1. See conversion table on Page 7.   Unitary Products Group   5 255427-YTG-F-1006   ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE 208/230-1-60   Field Wiring   Heater Model1,*   Max. O.C.P.2 Amps/Type   Model   Heater Amps   240V   20.0   Ampacity Min. Circuit   Wire Size - AWG 75°C   208V   27.54   39.73   49.21   70.88   27.54   39.73   49.21   70.88   85.32   92.54   29.29   41.48   50.96   72.63   87.07   94.29   53.08   74.75   89.19   96.42   118.08   240V   30.38   44.50   55.38   80.38   30.38   44.50   55.38   80.38   97.00   105.38   31.88   46.00   56.88   81.88   98.50   106.88   58.75   83.75   100.38   108.75   133.75   208V   30   240V   35   208V   10   8 240V   8 4HK*6500506   4HK*6500806   4HK*6501006   4HK165N1506   4HK*6500506   4HK*6500806   4HK*6501006   4HK16501506   4HK16501806   4HK16502006   4HK*6500506   4HK*6500806   4HK*6501006   4HK16501506   4HK16501806   4HK16502006   4HK*6501006   4HK16501506   4HK16501806   4HK16502006   4HK16502506   31.3   40   45   8 MV12B   40.0   50   60   8 6 60.0   90   90   4 3 20.0   30   35   10   8 8 31.3   40   45   8 40.0   50   60   8 6 MV12D   60.0   90   90   4 3 73.3   90   100   125   35   4 3 80.0   100   30   3 1 20.0   10   8 8 31.3   45   50   8 40.0   60   60   6 6 MV16C   MV20D   60.0   90   90   3 3 73.3   90   100   125   60   3 2 80.0   100   60   3 1 40.0   6 6 60.0   90   90   3 3 73.3   90   110   125   150   3 2 80.0   100   125   3 1 100.0   1 1/0   1. 30 KW 3 phase not approved for single source power supply.   2. OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.   * May be 0 (no breaker) or 1 (with breaker).   ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE 208/230-3-60   Field Wiring   Heater   Amps   240V   Heat Kit -   Three Phase   Max. O.C.P.1 Amps/Type   Models   Min. Circuit Ampacity   75°C Wire Size - AWG   208V   30.9   30.9   43.4   50.6   32.6   45.1   52.4   34.8   47.3   240V   34.3   34.3   48.8   57.1   35.1   49.6   58.0   37.6   52.1   208V   35   240V   35   208V   240V   12B   12D   4HK06501025   4HK06501025   4HK06501525   4HK06501825   4HK06501025   4HK06501525   4HK06501825   4HK06501025   4HK06501525   23.1   23.1   34.7   41.4   23.1   34.7   41.4   23.1   34.7   8 8 8 8 8 8 6 8 8 8 8 8 6 8 8 6 8 6 35   35   45   50   50   60   35   35   16C   20D   45   50   60   60   35   40   50   60   1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.   TABLE 1: Electrical Data - (For Multi-Source Power Supply) - Copper Wire - 208/230-3-60   Max. O.C.P.1 Amps/Type   Minimum Circuit Ampacity   75°C Wire Size - AWG   Heater   Model   Circuit   2nd   208/240 208/240 208/240 208/240 208/240 208/240 208/240   - / - 45 / 45 35 / 40 - / - 8 / 8 8 / 8 - / -   Models   1st   2nd   3rd   1st   3rd   1st   2nd   3rd   208/240   41.0 / 44.9   208/240   31.3 / 36.1   20D   4HK16502525   1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.   6 Unitary Products Group   255427-YTG-F-1006   ELECTRICAL DATA (FOR MULTI SOURCE POWER SUPPLY) - COPPER WIRE 208/230-1-60   1 Min. Circuit Ampacity   75°C Wire Size - AWG   Max. O.C.P. Amps/Type   Circuit   Circuit   Circuit   Heater   Model   Model   1st   208/240   2nd   3rd   1st   2nd   3rd   1st   2nd   3rd   208/240   208/240   208/240   50 / 60   50 / 60   50 / 60   50 / 60   50 / 60   50 / 60   50 / 60   60 / 60   50 / 60   60 / 60   50 / 60   208/240   25 / 25   25 / 25   40 / 50   45 / 50   25 / 25   40 / 50   45 / 50   25 / 25   40 / 50   45 / 50   45 / 50   208/240   208/240   8 / 6   8 / 6   8 / 6   8 / 6   8 / 6   8 / 6   8 / 6   6 / 6   8 / 6   6 / 6   8 / 6   208/240   10 / 10   10 / 10   8 / 8   208/240   MV12B   MV12D   4HK165N1506 49.2 / 55.4 21.7 / 25.0   4HK16501506 49.2 / 55.4 21.7 / 25.0   4HK16501806 45.6 / 51.2 39.7 / 45.8   4HK16502006 49.2 / 55.4 43.3 / 50.0   4HK16501506 51.0 / 56.9 21.7 / 25.0   4HK16501806 17.3 / 52.7 39.7 / 45.8   4HK16502006 51.0 / 56.9 43.3 / 50.0   4HK16501506 53.1 / 58.8 21.7 / 25.0   4HK16501806 49.5 / 54.6 39.7 / 45.8   4HK16502006 53.1 / 58.8 43.3 / 50.0   – – – – – – – – – – – – – – – – – 8 / 8   – – 10 / 10   8 / 8   – MV16C   MV20D   – – – 8 / 8   – – 10 / 10   8 / 8   – – – – – 8 / 8   4HK16502506 49.3 / 56.5 43.3 / 50.0 21.7 / 25.0   25 / 25   8 / 8   10 / 10   1. OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.   KW & MBH CONVERSIONS   208-VOLT   230-VOLT   240-VOLT   240-VOLT   .751   .918   FOR   OPERATION MULTIPLY   TABULATED KW & MBH BY   ELECTRICAL DATA - COOLING UNIT ONLY (60 Hz)   Total Motor Amps   60 Hertz   Minimum Circuit Ampacity   60 Hertz   Minimum Wire Size   AWG @ 75°C   Max. O.C.P.1 Amps/Type   MODEL   208V   4.7   230V   4.3   208V   5.9   230V   5.4   MV12B   MV12D   MV16C   MV20D   15   15   15   15   14   14   14   14   4.7   4.3   5.9   5.4   6.1   5.0   7.6   6.9   7.8   7.0   9.7   8.8   1. OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.   POWER WIRING   ELECTRIC HEAT   WITHOUT CIRCUIT BREAKER   3 PHASE (10 - 15 KW)   1 PHASE ELECTRIC HEAT   TYPICAL WIRING WITHOUT ELECTRIC HEAT   GND.   LUG   WITH CIRCUIT BREAKER   AS SHIPPED FROM FACTORY   SINGLE SOURCE   GND. LUG   GND.   LUG   GND. LUG   (2.5 - 25 KW) - 25 KW SHOWN   POWER   SUPPLY   GND. LUG   GND.   LUG   POWER   SUPPLY   1 PHASE ELECTRIC HEAT   WITH CIRCUIT BREAKER   & BREAKER BAR REMOVED   TERMINAL   BLOCK   ELECTRIC HEAT   WITHOUT CIRCUIT BREAKER   SINGLE SOURCE (2.5 - 10 KW)   MULTI-SOURCE (15 - 25 KW) - 25 KW SHOWN   GND. LUG   POWER   SUPPLY   GND.   LUG   GND.   LUG   GND. LUG   (JUMPER BAR)   POWER   SUPPLY 1   MAY BE 1, 2, OR 3   CIRCUIT BREAKERS   POWER   SUPPLY 2   POWER   SUPPLY   POWER   SUPPLY 3   POWER WIRING (208/230-1-60)   TERMINAL   BLOCK   NOTE: USE ONLY COPPER CONDUCTORS   MAY BE 1, 2, OR 3   CIRCUIT BREAKERS   CONNECT LEADS WITH WIRE NUTS   (TYPICAL ALL HEAT KITS)   Line Power   Unitary Products Group   7 255427-YTG-F-1006   Filter Rack - One of the following external filter rack accesso-   ries: 1FR07* or 1FR08* must be used when unit is installed   for application outlined.   ACCESSORIES   Refer to Price Manual for specific model numbers.   Electric Heaters - Models shown under Electrical Data   include sequencers and temperature limit switches and fus-   ible links for safe, efficient operation. Circuit breakers are pro-   vided where shown.   Combustible Floor Base - If an electric heat accessory   which is rated for greater than zero clearance to combustible   surfaces is installed in these air handlers in the downflow   operating positions on a combustible floor, one of the follow-   ing combustible floor base accessories is required: 1FB1817,   1FB1821, or 1FB1824.   Suspension Kit - Suspension Kit Model 1BH0601 is   designed specifically for upflow application of the units con-   tained in this technical guide. For suspension of these units in   horizontal applications, it is recommended to use angle sup-   port brackets with threaded rods at locations shown in air   handler installation instructions.   1/2”   3/4”   1/2”   1-1/2”   2” Max   Thick   Filter   1”   3-1/2”   C D 7/8”   1/2”   19-7/8”   3-1/2”   B 1/2”   (All four sides)   NOTE: May be used with up to a 2” filter.   Required for downflow application.   May also be used in upflow application.   22”   A 16-1/2”   20”   23-1/2”   21”   22”   All dimensions are inches. They are subject to change   without notice. Certified dimensions will be provided upon   request.   A ACCESSORY FOOTPRINT   FILTER RACK ACCESSORY   Filter Rack Model   Rack Dimensions Inches   Filter Dimensions Inches   Used With   Multi-Position Horizontal Only   A B C D Width   17-1/2   21   Length   22   Thickness   1FR0817   1FR0821   1FR0824   1FR0717   1FR0721   1FR0724   MV12B   MV16C   17-1/2   21   16-3/8   19-7/8   23-3/8   15-1/2   19   21   21   21   1 1 1 22   MV12D, MV20D   24-1/2   22-1/2   24-1/2   22   8 Unitary Products Group   255427-YTG-F-1006   AIR HANDLER   DEPTH   FRONT   DOWNFLOW   AIR HANDLER   FLOOR   APPROX. 1/2”   CLEARANCE   ALL AROUND   10-47/64   PLENUM   WARM AIR PLENUM   WITH 1” FLANGES   1 12-1/2   FLOOR OPENING   B A FIBERGLASS   INSULATION   FIBERGLASS TAPE   UNDER FLANGE   A AIR HANDLER   WIDTH   B A COMBUSTIBLE   FLOOR BASE   FLOOR   COMBUSTIBLE FLOOR   BASE ACCESSORY   B PLENUM   APPROX. 1/2”   CLEARANCE   ALL AROUND   1 1 C FLOOR OPENING   All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.   COMBUSTIBLE FLOOR BASE ACCESSORY   Dimensions   Floor Base Model   Used with   A B C D 1FB1817   1FB1821   1FB1824   MV12B   MV16C   19.9   23.4   26.9   18.0   21.5   25.0   14.9   18.4   21.9   16.9   20.4   23.9   MV12D, MV20D   Unitary Products Group   9 255427-YTG-F-1006   COOLING AIRFLOW DATA - MV MODELS   HIGH / LOW SPEED COOLING AND HEAT PUMP CFM   12D Air Handler   12B Air Handler   JUMPER SETTINGS   m3/min   m3/min   CFM   CFM   High   1307   1080   1270   943   Low   882   756   862   689   786   726   632   594   668   565   624   567   High   Low   25.0   21.4   24.4   19.5   22.3   20.6   17.9   16.8   18.9   16.0   17.7   16.1   High   1366   1097   1312   957   Low   869   717   856   646   761   703   580   520   629   495   567   488   High   38.7   31.1   37.2   27.1   33.0   29.8   24.4   20.9   26.2   18.6   23.5   16.8   Low   24.6   20.3   24.2   18.3   21.5   19.9   16.4   14.7   17.8   14.0   16.1   13.8   COOL Tap   ADJ Tap*   37.0   30.6   36.0   26.7   32.5   29.7   24.6   21.8   26.4   19.6   24.1   18.5   A B A B A C B D C D C D B B A A C B C B A A C C 1146   1050   870   1167   1051   863   771   739   931   927   693   658   851   830   655   594   16C Air Handler   20D Air Handler   JUMPER SETTINGS   m3/min   m3/min   CFM   CFM   High   1920   1699   1884   1558   1714   1451   1403   1288   1336   1214   1239   1098   Low   1321   1189   1296   1094   1193   1037   1009   947   High   Low   37.4   33.7   36.7   31.0   33.8   29.4   28.6   26.8   27.7   25.1   25.9   23.8   High   2209   2022   2178   1798   1965   1843   1596   1700   1608   1493   1430   1334   Low   1394   1394   1381   1378   1226   1143   1226   1066   1023   967   High   62.6   57.3   61.7   50.9   55.6   52.2   45.2   48.1   45.5   42.3   40.5   37.8   Low   39.5   39.5   39.1   39.0   34.7   32.4   34.7   30.2   29.0   27.4   25.8   24.8   COOL Tap   ADJ Tap*   54.4   48.1   53.3   44.1   48.5   41.1   39.7   36.5   37.8   34.4   35.1   31.1   A B A B A C B D C D C D B B A A C B C B A A C C 978   888   915   911   839   877   All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to   0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c.   external static pressure is not recommended.   NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower than what is required to operate an airflow switch on certain models of electronic air   cleaners. Consult the instructions for the electronic air cleaner for further details.   * The ADJ “D” tap should not be used.   HEATING AIRFLOW DATA - MV MODELS   HIGH / LOW SPEED COOLING AND HEAT PUMP CFM   12B Air Handler   12D Air Handler   JUMPER SETTINGS   m3/min   m3/min   CFM   CFM   CFM   CFM   High   1270   943   Low   791   714   643   567   High   Low   22.4   20.2   18.2   16.1   High   1312   957   Low   762   668   591   488   High   37.2   27.1   26.2   18.6   Low   21.6   18.9   16.7   13.8   COOL Tap   ADJ Tap*   36.0   26.7   26.4   19.6   A B C D A A A A 931   927   693   658   16C Air Handler   20D Air Handler   JUMPER SETTINGS   m3/min   m3/min   High   1884   1558   1336   1214   Low   1217   1065   823   High   Low   34.5   30.2   23.3   20.6   High   2178   1798   1608   1493   Low   1217   1036   748   High   61.7   50.9   45.5   42.3   Low   34.5   29.3   21.2   15.6   COOL Tap   ADJ Tap*   53.3   44.1   37.8   34.4   A B C D A A A A 727   551   All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to   0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c.   external static pressure is not recommended.   NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower than what is required to operate an airflow switch on certain models of electronic air   cleaners. Consult the instructions for the electronic air cleaner for further details.   * The ADJ “D” tap should not be used.   10   Unitary Products Group   255427-YTG-F-1006   APPLICATION FACTORS - RATED CFM VS. ACTUAL CFM   % OF RATED AIR FLOW   CAPACITY FACTOR   80%   0.96   90%   0.98   RATED CFM   1.00   110%   1.02   120%   1.03   Horizontal Right   Horizontal Left   Up Flow   Down Flow   Typical Applications with MC Multi-Position Coils   MA SERIES - Air Handler Control Wiring   Typical A/C - Cooling only Applications   MA SERIES - Air Handler Control Wiring   Typical A/C with Electric Heat Applications   AIR HANDLER   BOARD   AIR HANDLER   THERMOSTAT   1 - STAGE   BOARD   THERMOSTAT   1 - STAGE   AIR CONDITIONING   AIR CONDITIONING   R G R G R G Y R G Y Y / Y2   Y Y / Y2   Y W1   W2   C Y1   Y1   W2   W2   W2   * * W1   O W1   O HUMIDISTAT   HUMIDISTAT   W1   C HUM   X / L   COM   HUM   X / L   COM   C C COOLING MODELS WITH ELECTRIC HEAT   CONTROL WIRING - MA Series - Air Handler & New UPG HP Systems   Two Stage H/P with York Guard VI Board & Copeland “Ultra Tech”   Conventional Application - Not Hot Heat Pump   2 - STAGE SCROLL   HEAT PUMP   AIR HANDLER   BOARD   THERMOSTAT   R G R G R Y2   Y2   Y / Y2   Y1   Y2 OUT   Y1   Y1   W2 OUT   W2   W1   E W1 OUT   W O W O O * HUMIDISTAT   HUM   X / L   BS   X / L   C X / L   C COM   CONTROL WIRING - MV SERIES   Unitary Products Group   11   NOTES   Subject to change without notice. Printed in U.S.A.   255427-YTG-F-1006   Copyright © by York International/JCI. 2006. All rights reserved.   Supersedes: 255427-YTG-E-0906   Unitary   Products   Group   5005   York   Drive   Norman   OK   73069   |