Sanyo Ecoi C0905dxhn8 User Manual

Contact your local SANYO distributor  
for brochures on all other ranges of air  
conditioning and heating solutions  
GAS DRIVEN VRF  
ROOM AIR CONDITIONERS  
CO2 ECO HEATING SYSTEM  
ELECTRIC VRF  
ISO 9001: 2001  
Certificate Number: JQ116B  
ISO 14001: 2001  
Certificate Number: ECOOJ0303-33  
Indicates conformation  
with EC Directives  
ELECTRIC VRF  
GAS DRIVEN VRF  
Electric VRF  
SANYO reserves the right to make any variation in specification to the equipment described or to withdraw or replace products  
without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication  
are given in good faith, but are intended to present only general particulars and shall not form any part of the contract. For full  
installation details, please contact your SANYO distributor.  
COMMERCIAL SPLIT SYSTEMS  
ROOM AIR CONDITIONERS  
HEATING SOLUTIONS  
Rating Conditions  
The cooling and heating capacities are based on the following conditions:  
Cooling: Indoor temperature 27˚C DB/19˚C WB, Outdoor temperature 35˚C DB/24˚ C WB.  
Heating: Indoor temperature 20˚C DB, Outdoor Temperature 7˚C DB 6˚C WB.  
Printed using paper produced from 50% recycled material and 50% from sustainable forestry.  
SANYO Air Conditioners. The natural choice.  
SANYO Air Conditioners. The natural choice.  
ECOi_VRF_V1_2009  
Unique SANYO benefits  
New PAC2 System Design Software  
Designing a system for VRF (ECOi and GHP) and PACi  
Commercial Split Systems has never been easier  
SANYO-Installation cost saving design  
SANYO has identified the importance of ever-increasing  
demands for fast and accurate responses to customer requests  
in our industry. More and more emphasis is being placed upon  
energy-efficiency in our marketplace. The ability to calculate  
cooling/heating loads and produce information of actual design  
conditions is a major advantage to any architect, consultant,  
contractor or end user.  
Solenoid Valve Box  
Industry’s Smallest – 147mm High  
• Brazed connections  
• Requires only 1 Fixing for mounting  
• No transmission wiring at SVK  
• No mains power wiring at SVK  
• Comes inclusive with lead connection to indoor unit  
SANYO understands the ever-changing and demanding  
industry we are in and we are pleased to announce the  
launch of the next generation of our system design software  
program. The new advanced PAC2 system design software has  
been customised to make any selection and design process as  
quick and easy as possible. The software features a version of  
AC Calc Lite. This allows small building loadings to be accurately  
Saves the cost of local isolators and additional electrical  
wiring  
The new PAC2 system software can be used for all SANYO  
ECOi, GHP and PACi systems.  
calculated and directly imported into the PAC2 software.  
SANYO-Intelligent on site learning  
Compressor Road Map Control  
The design package utilises system wizards and import tools  
to enable both simple and complex systems to be created. In  
addition, the system will allow outdoor and indoor units to be  
dragged and dropped on an interactive desktop. This allows  
users to create everything from realistic floor plans with detailed  
piping and wiring schematics to send out with quotations,  
through to installation guidance drawings.  
Features include:  
• AC Calc Lite (included in the package)  
• Easy to use system wizards  
• Auto piping and wiring features  
• Converted duties for conditions and pipework  
• Auto CAD (DXF) export  
• Measures the average saturated suction temperature from the  
fan coil units  
• Measures the suction pressure and temperature entering the  
outdoor unit  
• Detailed wiring and pipework diagram  
• Calculates the best combination of compressors to run  
• Targets inverter compressor at 30 – 80% (most efficient)  
Reduces the running cost of the system  
The new PAC2 system software can be used for all SANYO ECOi, GHP and PACi systems.  
SANYO-Comfort control  
Air Discharge Temperature Control  
• Available on U indoor ducted units  
• Discharge air at below 10°C is uncomfortable and can cause  
draughts due to cold air dumping  
• Air off temperature can be controlled between 70C - 220C  
SANYO Solution  
No Control  
Guaranteed user comfort  
LED 1  
Blinking  
LED 2  
Refrigerant Volume “self checkprocedure  
Judgment mode  
Blinking  
ON  
ECOi 2 & 3WAY systems have an inbuilt self judgement mode to  
indicate the present system refrigerant volume.  
Normal  
Insufficient gas  
Overcharge  
ON  
Blinking  
OFF  
OFF  
Blinking  
From the outdoor unit you can start the self judgement mode,  
after completion (approx 30mins) the LED display’s the results.  
Judgment not possible  
Blinking alternately  
It ensures unit efficiency, avoids refrigerant wastage and  
assists with F-Gas complince.  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
4
3
ECOi Mini 4-6HP 2 Way Inverter Heat Pump VRF Systems  
ECOi 2 Way - features at a glance  
SANYO’s policy of product development continues  
with the expansion of the ECOi Mini, the 2 pipe  
heat pump small VRF system specifically designed  
for the European market.  
ECOi  
2
Way is  
a
high-performance heat  
pump system with excellent energy-saving  
features, designed for creating a comfortable  
environment when either heating or cooling  
is required.  
Offering between 11kW and 16kW cooling capacity in 3 sizes  
and up to 9 indoor units connected, the ECOi Mini sets new  
standards of performance and flexibility.  
• Heat pump systems offer heating or cooling  
• Single footprint size for all unit capacities  
Utilising R410A and DC inverter technology, SANYO offers  
VRF to a new and growing market.  
• DC inverter technology combined with R410A for excellent  
efficiency  
Forming a new key part of the SANYO VRF line up, the ECOi  
Mini is compatible with the same indoor units and controls  
of the electric and gas powered VRF range.  
• System configuration from 8HP to 48HP  
• Diversity ratio 50-130%  
Features at a glance  
• Industry low outdoor unit sound levels: from 54.5dB(A)  
• Quiet mode offers a further 3dB(A) reduction  
• Extended pipe runs of up to 150m  
• COPs up to 4.10  
• Single phase or three phase power supply  
• One AMP start current  
Highest COPs - lowest running costs  
• DC inverter technology combined with R410A for excellent  
efficiency  
HP  
4
5
6
• Heating capacity to -20°C  
EER Cooling  
COP Heating  
4.06  
4.34  
3.66  
4.10  
3.39  
3.84  
• COP of up to 4.34  
• Connectability of 40 indoor units from 24HP upwards  
• Units available from 8-16HP as single units  
• Diversity ratio 50-130%  
Wide operating range  
• 150m pipe runs  
The operating range for heating operation is to -20°C, the  
cooling range is to -10°C. The remote controller temperature  
setting offers a range from 16°C to 30°C.  
• Cooling operation to -10°C  
• Full range of indoor units and control options  
• Compact outdoor unit 1230x940x340mm  
Extended compressor life  
Longer piping means greater installation area  
The compressor running time is monitored and optimised  
by a microcomputer to ensure that there is no imbalance  
in the operation times of compressors on the same  
refrigerant circuit.  
Reducing the refrigerant volume by reducing piping size has  
extended the piping actual length to 150m (175m equivalent  
piping length).  
Save on piping cost  
R410A with low pressure loss enables smaller pipe sizes.  
This means reduced piping space, improved workability at  
the site and reduced piping material costs.  
HP  
4
5
6
Model name  
Power supply  
Cooling capacity  
Heating capacity  
EER Cooling  
SPW-CR365GXH56B/SPW-CR365GXH8B SPW-CR485GXH56B/SPW-CR485GXH8B SPW-CR605GXH56B/SPW-CR605GXH8B  
230V, 1 phase, 50/60Hz/400, 3 phase, 50/60Hz  
System difference of  
elevation: 50m *1  
kW  
kW  
11.20  
12.50  
4.06  
14.00  
16.00  
3.66  
15.50  
17.60  
3.39  
Extended operating range - better output at lower  
temperatures  
2
*
COP Heating  
4.34  
4.10  
3.84  
Actual length: 150m  
The operating range for heating has been extended to  
-15°C. The remote controller temperature setting for heating  
operation has also been extended from 16°C to 30°C.  
Running  
amperes  
Power input kW  
Running  
amperes  
Power input kW  
(Equivalent length: 175m)  
A
14.1/4.34  
2.76  
19.6/6.02  
3.83  
23.4/7.18  
4.57  
Cooling  
Heating  
Electric rating  
Difference in elevation  
between indoor units: 15m  
A
14.7/4.52  
2.88  
19.9/6.13  
3.90  
23.4/7.19  
4.58  
Recommended fuse size (motor  
rated)  
1ph 3ph  
25/16  
32/16  
Dimensions (H/W/D)  
Net weight  
Air circulation  
mm  
kg  
m3/min  
kg  
1,230x940x340  
104  
100  
3.5  
*1: 40m if the outdoor unit is below the indoor unit.  
*2: Total length of pipe: no more than 300m  
Refrigerant amount at shipment  
Inches  
(mm)  
Inches  
(mm)  
Gas  
5/8 (15.88)  
3/4 (19.05)  
Piping connection  
Liquid  
3/8 (9.52)  
Operating sound normal mode  
Operating sound quiet mode  
51.0  
48.0  
52.0  
49.0  
dB(A)  
Higher COPs - lower running costs  
Cooling  
Heating  
-10°C DB +43°C DB  
-20°C DB +15°C DB  
8
Ambient temperature operating  
range  
HP  
8
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
36  
38  
40  
42  
44  
46  
48  
Maximum number of indoor units  
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.  
* Please refer to tube sizing charts for pipe selections and pipe length parameters.  
6
9
EER Cooling  
COP Heating  
3.74  
4.10  
3.54  
4.10  
3.50  
3.91  
3.45  
3.91  
3.38  
3.79  
3.63  
4.06  
3.54  
4.06  
3.51  
3.97  
3.49  
3.96  
3.44  
3.88  
3.43  
3.84  
3.41  
3.85  
3.38  
3.79  
3.50  
4.00  
3.47  
3.94  
3.47  
3.89  
3.45  
3.91  
3.42  
3.86  
3.43  
3.83  
3.40  
3.83  
3.38  
3.79  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
6
5
ECOi 2 Way Heat Pump VRF Inverter Systems  
HP  
8
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
36  
38  
40  
42  
44  
46  
48  
C0705DXHN8 C0905DXHN8 C1155DXHN8 C1305DXHN8 C1405DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8  
8 C0705DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8  
16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8  
10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8  
10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8  
380/400/415V - 3 phase/50,60Hz  
Model  
Power supply  
Cooling capacity  
Heating capacity  
EER Cooling  
kW  
kW  
kW  
kW  
22.40  
25.00  
3.74  
28.00  
31.50  
3.54  
33.50  
37.50  
3.50  
40.00  
45.00  
3.45  
45.00  
50.00  
3.38  
50.40  
56.50  
3.63  
56.00  
63.00  
3.54  
61.50  
69.00  
3.51  
68.00  
76.50  
3.49  
73.00  
81.50  
3.44  
78.50  
87.50  
3.43  
85.00  
95.00  
3.41  
90.00  
100.00  
3.38  
96.00  
108.00  
3.50  
101.00  
113.00  
3.47  
107.00  
119.00  
3.47  
113.00  
127.00  
3.45  
118.00  
132.00  
3.42  
124.00  
138.00  
3.43  
130.00  
145.00  
3.40  
135.00  
150.00  
3.38  
COP Heating  
4.05  
4.06  
3.91  
3.91  
3.79  
4.06  
4.06  
3.97  
3.96  
3.88  
3.84  
3.85  
3.79  
4.00  
3.94  
3.89  
3.91  
3.86  
3.83  
3.83  
3.79  
Running  
amperes  
Power  
input  
Running  
amperes  
Power  
input  
A
10.1/9.6/9.3 13.3/12.7/12.2 16.2/15.4/14.8 20.0/19.0/18.3 23.0/21.8/21.0 23.4/22.3/21.5 26.6/25.4/24.4 29.5/28.1/27 33.3/31.7/30.5  
5.99 7.90 9.58 11.60 13.30 13.90 15.80 17.50 19.50  
10.4/9.9/9.5 13.1/12.4/12.0 16.2/15.4/14.8 19.9/18.9/18.2 22.8/21.6/20.9 23.5/22.3/21.5 26.2/24.8/24.0 29.3/27.8/26.8 33.0/31.3/30.2  
36.3/34.5/33.2 39.2/37.2/35.8 43.0/40.8/39.3 46.0/43.6/42.0 46.6/44.4/42.7 49.6/47.2/45.4 52.5/49.9/48.0 56.3/53.5/51.5 59.3/56.3/54.2 62.2/59.0/56.8 66.0/62.6/60.3 69.0/65.4/63.0  
21.20 22.90 24.90 26.60 27.40 29.10 30.80 32.80 34.50 36.20 38.20 39.90  
35.9/34.0/32.9 39.0/37.0/35.7 42.7/40.5/39.1 45.6/43.2/41.8 46.1/43.7/42.2 49.0/46.4/44.9 52.1/49.4/47.7 55.8/52.9/51.1 58.7/55.6/53.8 61.8/58.6/56.6 65.5/62.1/60.0 68.4/64.8/62.7  
Cooling  
kW  
A
Electric  
rating  
Heating  
kW  
6.17  
7.75  
32  
9.60  
11.50  
13.20  
13.90  
15.50  
32x2  
17.70  
20.70  
22.60  
23.10  
26.10  
28.00  
29.30  
31.20  
30.60  
34.70  
34.20  
37.10  
37.90  
42.00  
1x40  
1x32  
1x40  
1x32  
2x32  
1x40  
1x32  
2x40  
Recommended fuse sizes (motor rated)  
40  
2x40  
3x40  
1035  
Dimensions  
Net weight  
(H/W/D) mm  
kg  
1887×890×890 (+60)  
295  
180  
1887×1880×890 (+60)  
590  
1887×1880×890 (+60)  
220+180  
1887×2870×890 (+60)  
985  
245  
150  
345  
540  
160+150  
640  
200+160  
640  
690  
220+220  
929  
Air circulation  
m3/min  
160  
200  
220  
160+160  
180+160  
220+160  
200+160+160 220+160+160 220+180+160 220+200+160 220+220+160 220+220+180 220+220+200 220+220+220  
Gas  
Liquid  
Balance  
3/4 (19.05)  
7/8 (22.22)  
1 1/8 (28.58)  
1 3/8 (34.92)  
1 5/8 (41.27)  
Piping  
connection  
3/8 (9.52)  
1/2 (12.7)  
5/8 (15.88)  
3/4 (19.05)  
Inches (mm)  
dB(A)  
1/4 (6.35)  
Operating sound normal  
mode  
54.5  
51.5  
55.0  
52.0  
56.0  
53.0  
60.0  
57.0  
61.0  
58.0  
58.0  
55.0  
58.5  
55.5  
61.5  
58.5  
62.0  
59.0  
62.5  
59.5  
63.5  
64.0  
61.0  
62.5  
59.5  
63.0  
60.0  
64.5  
61.5  
65.0  
62.0  
65.5  
62.5  
66.0  
63.0  
Operating sound  
quiet mode  
60.5  
Cooling  
Heating  
-10°C DB +43°C DB  
-20°C DB +15°C DB  
Ambient temperature  
operating range  
Maximum number of indoor units  
13  
16  
19  
23  
26  
29  
33  
36  
40  
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.  
* Please refer to tube sizing charts for pipe selections and pipe length parameters.  
System example for ECOi 2 Way  
Dimensions of unit combinations (ECOi 2 Way and 3 Way)  
Outdoor unit  
1880  
100  
18 to 32 HP  
8 to 16 HP  
890 (Top plate dimension)  
890 (Top plate dimension)  
890 (Top plate dimension)  
Since all piping is concentrated into one  
pipe shaft, you can minimise piping space  
and construction labour.  
Concentration  
SANYO make it possible to link outdoor  
units together for a large capacity (48HP)  
Connection  
790 (Installation hole pitch)  
790 (Installation hole pitch)  
790 (Installation hole pitch)  
200  
1780 (Installation hole pitch)  
Indoor unit  
Indoor unit  
If indoor/outdoor units need servicing, a ball valve  
(optional) cuts off non-operational units to let other  
units stay running.  
2870  
890 (Top plate dimension)  
34 to 48 HP  
100  
100  
890 (Top plate dimension)  
890 (Top plate dimension)  
System limitations  
Maximum number of combined outdoor units  
Maximum HP of combined outdoor units  
Maximum number of connectable indoor units  
Indoor/outdoor unit capacity ratio  
3
48HP  
40  
Addition  
50-130%  
150m  
50(40)m  
300m  
If your indoor capacity load changes in the future, it’s easy to add  
on both indoor and outdoor units using the same piping.  
Maximum actual piping length  
Maximum level difference (when outdoor unit is lower)  
Maximum total piping length in one direction  
790 (Installation hole pitch)  
200 790 (Installation hole pitch)  
200 790 (Installation hole pitch)  
(2 Way version illustrated)  
2770 (Installation hole pitch)  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
8
7
ECOi 3 Way - features at a glance  
Solenoid Valve Kit  
ECOi 3 Way is one of the most advanced VRF heat  
recovery systems available. Not only offering  
high-efficiency and performance for simultaneous  
heating and cooling, its sophisticated design makes  
installation and maintenance much easier.  
Fully-automatic simultaneous Cooling/Heating operation and heat recovery  
System Example  
Any design and layout can be used in  
a
single system  
• Cooling operation is possible down to an outdoor  
temperature of -10°C  
• Simultaneous heating and cooling for total control  
• Single footprint size for all unit capacities (8-16HP)  
Solenoid Valve Kit  
ATK-RZP56BG  
ATK-RZP160BG  
• DC inverter technology combined with R410A for  
excellent efficiency  
Uptomax.40indoorunits  
Way ECOi Multi enables  
simultaneous heating and  
cooling operation by each  
solenoid valve kit.  
• System configuration from 8HP to 48HP  
• Diversity ratio 50-130%  
3
• Sound levels: from 54.5dB(A)  
• Quiet mode offers a further 3dB(A) reduction  
• Extended pipe runs of up to 150m  
• COPs to 4.1  
[Cooling]  
[Heating]  
[Heating]  
[Stop]  
[Cooling]  
[Cooling]  
Same operation  
Liquid pipe  
medium-temperature,  
medium-pressure liquid pipe  
Discharge pipe  
high-temperature,  
high-pressure gas pipe  
Suction pipe  
low-temperature,  
low-pressure gas pipe  
• Provides cooling down to -10°C ambient  
• Connectability of 40 indoor units from 24HP upwards  
Extended operating range - better output at lower  
temperatures  
The operating range for heating has been extended to  
-20°C. The remote controller temperature setting for heating  
operation has also been extended from 16°C to 30°C.  
Cooling: -10˚C DB ~ 43˚C DB  
Heating: -20˚C WB ~ 15˚C WB  
8HP ~ 48HP  
Solenoid Valve Kit  
Up to 5 indoor units with individual remote control  
can be connected off 1 SVK box.  
Box dimensions: L 166mm X 147mm X 217mm  
There is improved performance at lower ambient conditions  
due to SANYO’s unique wrap-around outdoor unit coil design  
and active defrost management.  
Higher COPs - lower running costs  
HP  
8
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
3.4  
3.8  
30  
32  
34  
36  
38  
40  
42  
3.4  
44  
46  
48  
Timer remote controller  
3.78  
4.09  
3.45  
3.95  
3.41  
3.81  
3.45  
3.91  
3.38  
3.79  
3.57  
4.01  
3.46  
3.96  
3.44  
3.88  
3.45  
3.92  
3.41  
3.84  
3.41  
3.85  
3.38  
3.79  
3.45  
3.93  
3.41  
3.88  
3.42  
3.84  
3.42  
3.88  
3.41  
3.81  
3.40  
3.83  
3.38  
3.79  
EER Cooling  
COP Heating  
3.84  
RCS-TM80BG  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
10  
9
ECOi 3 Way Heat Recovery VRF Inverter Systems  
HP (Combined systems)  
Model  
8
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
36  
38  
40  
42  
44  
46  
48  
C0705DZH8 C0905DZH8 C1155DZH8 C1305DZH8 C1405DZH8 8 C0705DZH8 10 C0905DZH8 10 C0905DZH8  
10 C0905DZH8 10 C0905DZH8 12 C1155DZH8  
10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8  
14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8  
14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8  
Power supply  
Cooling capacity  
Heating capacity  
EER Cooling  
380/400/415V - 3phase/50Hz  
kW  
kW  
kW  
kW  
22.40  
25.00  
3.78  
28.00  
31.50  
3.45  
33.50  
37.50  
3.41  
40.00  
45.00  
3.45  
45.00  
50.00  
3.38  
50.40  
56.50  
3.57  
56.00  
63.00  
3.46  
61.50  
69.00  
3.44  
68.00  
76.50  
3.45  
73.00  
81.50  
3.41  
78.50  
87.50  
3.40  
85.00  
95.00  
3.41  
90.00  
100.00  
3.38  
96.00  
108.00  
3.45  
101.00  
113.00  
3.41  
107.00  
119.00  
3.42  
113.00  
127.00  
3.42  
118.00  
132.00  
3.40  
124.00  
138.00  
3.41  
130.00  
145.00  
3.40  
135.00  
150.00  
3.38  
COP Heating  
4.09  
3.95  
3.81  
3.91  
3.79  
4.01  
3.96  
3.88  
3.92  
3.84  
3.80  
3.85  
3.79  
3.93  
3.88  
3.84  
3.88  
3.84  
3.81  
3.83  
3.79  
Running amperes A  
10.0/9.5/9.2 13.7/13.0/12.6 16.6/15.7/15.2 20.0/19.0/18.3 23.0/21.8/21.0 23.8/22.6/21.8 27.3/26.0/25.0 30.2/28.7/27.7  
5.93 8.12 9.82 11.59 13.31 14.10 16.20 17.90  
10.3/9.8/9.4 13.5/12.8/12.3 16.6/15.8/15.2 19.9/18.9/18.2 22.8/21.6/20.9 23.9/22.6/21.8 26.8/25.5/24.6 30.0/28.5/27.5  
33.6/31.9/30.8 36.5/34.7/33.5 39.4/37.5/36.1 43.0/40.8/39.4 45.9/43.6/42.1 47.5/45.1/43.5 50.5/48.0/46.3 53.0/51.0/49.0 57.0/54.0/52.0 60.0/57.0/55.0 63.0/60.0/58.0 66.0/63.0/60.0 69.0/65.0/63.0  
19.70 21.40 23.10 24.90 26.60 27.80 29.60 31.30 33.00 34.70 36.40 38.20 39.90  
33.3/31.6/30.5 36.2/34.4/33.1 39.3/37.3/36.0 42.6/40.5/39.0 45.6/43.3/41.7 46.9/44.6/43.0 49.7/47.2/45.5 53.0/50.0/48.0 56.0/54.0/52.0 59.0/56.0/54.0 63.0/59.0/57.0 65.0/62.0/60.0 68.0/65.0/63.0  
Cooling  
Heating  
Power input kW  
Running amperes A  
Power input kW  
Electric ratings  
6.11  
7.97  
9.84  
11.51  
13.19  
14.10  
15.90  
17.80  
19.50  
21.20  
23.30  
24.70  
26.40  
27.50  
29.10  
31.00  
32.70  
34.40  
36.20  
37.90  
39.60  
1x40  
1x32  
2x32  
1x40  
1x32  
2x40  
Recommended fuse sizes (motor rated)  
32  
40  
32x2  
2x40  
680  
3x40  
1020  
Dimensions  
Net weight  
Airflow  
(H/W/D) mm  
kg  
1,887x890x890 (+60)  
180  
1,887x1,880x890 (+60)  
1,887x1,880x890 (+60)  
180+220  
1887x2870x890 (+60)  
970  
290  
160  
340  
580  
160+160  
630  
160+220  
920  
m3/min  
150  
200  
220  
150+160  
160+180  
160+200  
200+220  
220+220  
160+160+200 160+160+220 160+180+220 160+200+220 160+220+220 180+220+220 200+220+220 220+220+220  
Gas  
Discharge  
3/4 (19.05)  
5/8 (15.88)  
7/8 (22.22)  
1 1/8 (28.58)  
1 3/8 (34.92)  
1 5/8 (41.27)  
3/4 (19.05)  
7/8 (22.22)  
1 1/8 (28.58)  
1 3/8 (34.92)  
Piping connection  
Inches (mm)  
Liquid  
3/8 (9.52)  
1/2 (12.7)  
5/8 (15.88)  
3/4 (19.05)  
Balance  
3/8 (9.52)  
Operating sound normal mode  
Operating sound quiet mode  
54.5  
51.5  
55.0  
52.0  
56.0  
53.0  
60.0  
57.0  
61.0  
58.0  
57.8  
54.8  
58.0  
55.0  
58.5  
55.5  
57.8  
54.8  
60.1  
57.1  
60.4  
57.4  
61.0  
58.0  
61.5  
58.5  
60.8  
57.8  
61.3  
58.3  
61.5  
58.5  
62.0  
59.0  
62.4  
59.4  
62.6  
59.6  
63.0  
60.0  
63.3  
60.3  
dB(A)  
Cooling  
Heating  
-10°C DB +43°C DB  
-20°C DB +15°C DB  
Ambient temperature  
operating range  
Maximum number of indoor units  
13  
16  
19  
23  
26  
29  
33  
36  
40  
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.  
* Please refer to tube sizing charts for pipe selections and pipe length parameters.  
ATK-RZP56BG and ATK-RZP160BG  
Industry’s smallest changeover boxes - fewer locating  
problems  
Dimensions ECOi 2 Way and 3 Way (8-16 HP)  
The SANYO solenoid valve kit is only 147mm high (without the  
removable bracket) and takes its power from the indoor unit,  
saving the cost of an additional supply.  
• No additional power supply required  
• Single mounting fix point  
• 2 sizes avaliable (up to 5.6kW and 7.5 to 16kW)  
Solenoid Valve Kit  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C  
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB  
12  
11  
VRF Indoor Unit Range for ECOi and GHP  
Self-diagnosing function  
Mild dry  
Wider operation  
Automatic fan operation  
Air Sweep  
Comfortable auto-flap control  
Built-in drain pump  
Automatic restart function for power failure  
Model size  
Capacity  
7
9
12  
16  
18  
22  
25  
36  
48  
60  
76  
96  
Wireless remote control  
Cooling  
Heating  
Cooling  
Heating  
2.2  
2.5  
7,500  
8,500  
SPW-X075XH  
2.8  
3.2  
9,600  
11,000  
SPW-X095XH  
3.6  
4.2  
12,000  
14,000  
SPW-X125XH  
4.5  
5.0  
15,000  
17,000  
SPW-X165XH  
5.6  
6.3  
19,000  
21,000  
SPW-X185XH  
6.4  
7.0  
22,000  
24,000  
7.3  
8.0  
25,000  
27,000  
SPW-X255XH  
10.6  
11.4  
36,000  
39,000  
SPW-X365XH  
14.0  
16.0  
47,800  
54,600  
SPW-X485XH  
16.0  
18.0  
54,600  
61,500  
SPW-X605XH  
22.4  
25.0  
76,400  
85,300  
28.0  
31.5  
95,500  
107,500  
kW  
Built-in infra red  
sensorl  
Separately installed  
infra red sensor  
Functions  
Capacity BTU/h  
SPW-XDR74GXH56B SPW-XDR94GXH56B SPW-XDR124GXH56B SPW-XDR164GXH56B SPW-XDR184GXH56B  
SPW-XDR254GXH56B  
Panel  
PNR-XD484GHAB  
SPW-XDR364GXH56B SPW-XDR484GXH56B SPW-XDR604GXH56B  
X Type  
Panel  
Panel  
Panel  
Panel  
Panel  
Panel  
Panel  
Panel  
Semi-Concealed  
Cassette  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
SPW-XM075XH  
Panel  
PNR-XM185  
SPW-XM095XH  
Panel  
PNR-XM185  
SPW-XM125XH  
Panel  
PNR-XM185  
SPW-XM165XH  
Panel  
PNR-XM185  
SPW-XM185XH  
Panel  
PNR-XM185  
XM Type  
Semi-Concealed  
SPW-US075XH  
SPW-US095XH  
SPW-US125XH  
SPW-US165XH  
SPW-US185XH  
US Type  
Concealed Duct  
SPW-U075XH  
SPW-UR74GXH56B  
SPW-U095XH  
SPW-U125XH  
SPW-U165XH  
SPW-U185XH  
SPW-U255XH  
SPW-U365XH  
SPW-U485XH  
SPW-U605XH  
SPW-UR94GXH56B SPW-UR124GXH56B SPW-UR164GXH56B SPW-UR184GXH56B  
SPW-UR254GXH56B  
SPW-UR364GXH56B SPW-UR484GXH56B SPW-UR604GXH56B  
U Type  
Concealed Duct  
25,48 type  
SPW-DR364GX-  
SPW-DR484GX-  
DR Type  
Concealed  
Duct  
SPW-DR254GXH56B  
SPW-DR764GXH56B SPW-DR964GXH56B  
H56B  
H56B  
76,96 type  
SPW-K075XH  
SPW-K095XH  
SPW-K125XH  
SPW-T125XH  
K Type  
Wall Mounted Unit  
SPW-KR164GXH56B SPW-KR184GXH56B  
SPW-KR254GXH56B  
KR Type  
Wall Mounted Unit  
SPW-T165XH  
SPW-T185XH  
SPW-T225XH  
SPW-TDR254GXH56B  
SPW-T365XH  
SPW-TDR364GXH56B SPW-TDR484GXH56B  
SPW-T485XH  
SPW-TDR124GXH56B SPW-TDR164GXH56B SPW-TDR184GXH56B  
T Type Ceiling-  
Mounted Unit  
FTR Type  
Floor/Ceiling  
Mounted Units  
SPW-FTR74EXH56B SPW-FTR94EXH56B SPW-FTR124EXH56B SPW-FTR164EXH56B SPW-FTR184EXH56B SPW-FTR224EXH56B  
SPW-FUR74EXH56B SPW-FUR94EXH56B SPW-FUR124EXH56B SPW-FUR164EXH56B SPW-FUR184EXH56B SPW-FUR224EXH56B  
FUR Type  
Floor/Ceiling  
Slim Concealed Duct  
SPW-FR74GXH56B  
SPW-FR94GXH56B  
SPW-FR124GXH56B SPW-FR164GXH56B SPW-FR184GXH56B  
SPW-FR254GXH56B  
SPW-FMR254GXH56B  
FR Type Floor  
Standing Unit  
FMR Type  
Concealed Floor  
Standing Unit  
SPW-FMR74GXH56B SPW-FMR94GXH56B SPW-FMR124GXH56B SPW-FMR164GXH56B SPW-FMR184GXH56B  
SPW-ADR74GXH56B SPW-ADR94GXH56B SPW-ADR124GXH56B  
Panel  
PNR-AD124GHB  
ADR Type  
Semi-Concealed  
Cassette 1-Way  
Air Discharge  
Panel  
PNR-AD124GHB  
Panel  
PNR-AD124GHB  
SR Type  
SPW-SR74GXH56B  
Panel  
PNR-S124GHB  
SR94GXH56B  
Panel  
PNR-S124GHB  
SR124GXH56B  
Panel  
PNR-S124GHB  
SR164GXH56B,  
Panel  
PNR-S124GHB  
SR184GXH56B  
Panel  
PNR-S124GHB  
SPW-SR254GXH56B  
Panel  
PNR-S253GHANB  
Semi-Concealed  
Cassette 2-Way  
Air Discharge  
SPW-LDR94GXH56B SPW-LDR124GXH56B SPW-LDR164GXH56B SPW-LDR184GXH56B  
Panel  
PNR-LD254GHAB  
SPW-LDR254GXH56B  
Panel  
PNR-LD254GHAB  
LDR Type  
Semi-Concealed  
Slim Cassette  
Panel  
PNR-LD254GHAB  
Panel  
PNR-LD254GHAB  
Panel  
PNR-LD254GHAB  
GU Type  
Total Heat  
Exchanger  
SPW-GU055XH  
SPW-GU075XH  
SPW-GU105XH  
13  
14  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
Room Control Systems Overview  
Centralised Control Systems Overview  
A wide variety of control options to meet the requirements of different customers.  
Operation system  
Individual control systems  
Timer operation  
Centralised control systems  
Simplified charge ratio for each tenant  
Operation with various  
Only ON/OFF operation from  
function from central  
central station  
Normal  
Operation from  
each seat  
Daily and  
Requirements  
Simple operation  
operation  
weekly programme  
Personal computer  
Touch screen panel  
station  
(field supply)  
External appearance  
External appearance  
Web  
application  
Wireless remote  
controller  
RCS-SH80BG.WLB  
RCS-TH80BG.WLB  
RCS-BH80AG.WLB  
RCS-TRP80BG.WLB  
RCS-SH1BGB  
Simplified remote  
controller  
Timer wired  
Schedule timer  
SHA-TM64AGB  
remote controller  
System controller  
SHA-KC64AGB  
ON/OFF controller  
SHA-KC16KAGB  
Intelligent controller  
SHA-KT256EG  
Communication adaptor  
SHA-KA128AGB  
Type, model name  
Type, model name  
RCS-TM80BG  
RCS-KR1EG  
Number of indoor units which  
can be controlled  
64 groups,  
1 group, 8 units  
1 group, 8 units  
1 group, 8 units  
Number of indoor units which can be  
controlled  
64 groups,  
16 groups,  
64 units x 4 systems,  
max. 256 units  
2 systems,  
max. 64 units  
max. 64 units  
max. 64 units  
max. 128 units  
Power supply from the system  
controller.  
Up to 10 units can be  
connected to one system.  
Up to 8 units (4 main units + 4  
sub units) can be connected  
to one system.  
Use without remote controller  
is impossible.  
A communication adaptor  
(SHA-KA128AGB) must be  
installed for three or more  
systems.  
When there is no system  
controller, connection is  
possible to the T10 terminal  
of an  
Up to 2 units can be  
connected per group.  
Up to 2 units can be  
connected per group.  
Up to 2 units can be  
connected per group.  
Main unit/sub unit (1 main  
unit + 1 sub unit) connection  
is possible.  
Use without remote controller  
is possible.  
Maximum 500 indoor units  
(128 per communication  
adaptor)  
Use limitations  
Use limitations  
indoor unit.  
Connectable  
indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
Connectable  
indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
Function  
Function  
ON/OFF  
-
-
-
-
-
-
ON/OFF  
Mode setting  
Fan speed setting  
Mode setting  
Fan speed setting  
-
-
-
-
*1  
*1  
*1  
Temperature setting  
Air flow direction  
Temperature setting  
Air flow direction  
*1  
*1  
*1  
Permit/Prohibit switching  
Weekly programme  
-
-
-
Permit/Prohibit switching  
Weekly programme  
-
-
-
*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)  
15  
16  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
GU Type Heat Exchanger  
CFR Units  
SANYO’s new heat recovery ventilation system allows  
total control via a system network whilst modulating the  
temperature and humidity of incoming air supply.  
The CFR-PHE unit structure is constructed from Aluzink  
frame work and galvanised steel with 20 mm thick fire  
resistant acoustic insulation, reducing both weight and  
sound levels to a minimum. The system is supplied with  
ducted spigots which can be positioned either at the front  
or side of the unit to ease installation.  
• Integration of heat recovery ventilation and DX coil  
technology for optimum air temperature control  
• The DX coil can be connected to all ECO & GHP  
outdoor units  
• High efficiency heat exchanger  
• Easy to clean filters  
• Easy to clean filter  
The high efficiency low pressure loss total heat exchanger is  
made of specially treated paper to enable the unit to be as  
efficient as 76% during normal operation. This allows system to  
recover both latent and sensible heat.  
• Compact design  
• Filter option  
• 3 Way: Solenoid valve kit is required for each unit  
• 2 Way: RAP kit is required for each unit  
Controller Options  
Timer remote controller  
Installation example  
Humidification DX coil  
(optional)  
Heat exchanger  
Wireless remote controller  
Simplified remote controller  
Exhaust air  
Fresh air  
Supply air  
Return air  
RCS-TM80BG  
RCS-BH80BG.WL  
RCS-KR1EG  
Indoor unit specifications  
Model Name  
Indoor unit specifications  
Model CFR/ CFR-PHE  
SPW-GU055XH  
SPW-GU075XH  
SPW-GU105XH  
33  
55  
110  
175  
220  
Air circulation (H) m3/h  
Power source  
500  
750  
220/230/240V, 1 phase - 50 Hz  
8.2 (2.6)*1  
1,000  
Nominal air flow *  
External Static Pressure  
Sound Pressure **  
Fans  
Power in  
Absorbed power  
Fan speeds  
m3/hr  
pa  
dB(A)  
300  
45  
43  
620  
55  
51  
920  
65  
50  
1580  
70  
53  
1850  
77  
52  
UK Cooling  
kW  
kW  
5.3 (1.7)*1  
6.5 (2.3)*1  
10.7 (3.4)*1  
12.6 (4.6)*1  
Fresh air load  
treatment capacity  
UK Heating  
UK Cooling  
UK Heating  
9.8 (3.5)*1  
%
%
59  
Enthalpy exchange  
efficiency  
Watts  
A
no  
184  
0.75  
340  
1.8  
294  
2.2  
700  
4.4  
3
700  
4.8  
67  
75  
5.6  
19,000  
0.737  
0.737  
3.2  
Temp exchange efficiency  
1
kW  
BTU/h  
kW  
kW  
Amps  
Amps  
3.6  
12,000  
0.532  
0.532  
2.4  
7.3  
25,000  
0.798  
0.798  
3.5  
Equivalent cooling capacity  
Insulation Class  
F
Electrical supply  
Bioxigen Elements (PHE only)  
Number of elements  
Electrical supply  
Power in  
v/ph/htz  
230/1/50  
Cooling  
Power input  
Heating  
2 X C  
2 X F  
Cooling  
Running current  
Heating  
v/ph/htz  
Watts  
230/1/50  
8
EU3  
2.4  
3.2  
3.5  
8
8
8
8
Type  
Sirocco fan  
221 (188)  
264 (218)  
Filter  
External static pressure-return air  
External static pressure-supply air  
Output  
Pa  
Pa  
kW  
db(A)  
mm  
183 (170)  
205 (182)  
0.28 (4P)x2  
135 (88)  
176 (137)  
Fan motor  
Paper Heat Exchanger  
Temperature Efficiency heating ***  
Temperature Efficiency cooling ****  
CFR-PHE  
76%  
62%  
74%  
60%  
72%  
58%  
68%  
54%  
73%  
59%  
0.35 (4P)x2  
Sound pressure level (C/H)  
Height  
Width  
46 (Cooling), 47 (Heating)  
47 (Cooling), 48 (Heating)  
48 (Cooling), 49 (Heating)  
1220  
425  
1785  
1000  
450  
1903  
* Nominal air flow  
Dimensions  
mm  
mm  
mm (inches)  
mm (inches)  
** Sound pressure 1.5 mts from the unit in free field  
*** Data referred to -50C 80% RH OAT room condition 200C 50% RH  
**** Data referred to 320C 50% RH OAT room condition 260C 50% RH  
Depth  
Liquid (flare)  
Piping connections Gas (flare)  
Drain piping  
1120  
6.35 (1/4)  
12.7 (1/2)  
VP-25  
Connection duct diameter  
Net weight  
mm  
kg  
250  
300  
168  
134  
153  
The values in ( ) for the external static pressure and operating sound are for use of booster cable. *1: Heat recovery capacity by heat exchanger. Data subject to change without notice.  
17  
18  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  

Monarch Plt200 User Manual
Panasonic Cs F24dd1es User Manual
Panasonic Dp 6530 User Manual
Quasar Pag User Manual
Samsung As24cm1x User Manual
Schumacher Scf 2500a User Manual
Sharp Mx Fn13 User Manual
Sharp Mx Pk10 User Manual
Xerox Pro 35 User Manual
Xerox Workcentre 4118x User Manual