Sanyo Eco G Sgp Ew190m2g2w User Manual

Gas Driven VRF  
M Series  
GAS DRIVEN VRF  
ELECTRIC VRF  
COMMERCIAL SPLIT SYSTEMS  
ROOM AIR CONDITIONERS  
HEATING SOLUTIONS  
SANYO Air Conditioners. The natural choice.  
What is a GHP?  
SANYO GHP - the natural choice  
The application principle of Variable Refrigerant Flow  
(VRF) systems for projects with multiple indoor unit is now  
very much an integral element of the UK air conditioning  
market place.  
Gas Heat Pump M Series - the perfect solution SANYO benefits  
when you’re short of power  
SANYO has been developing GHP VRF systems since  
1980, during which time we have been committed to  
delivering ground-breaking technology. As a result, the  
commercial range of GHP VRF systems is leading the  
industry in the development of efficient and flexible  
systems, making them the natural choice for commercial  
projects, especially for those projects where power  
restrictions apply. As you would expect, all of our gas  
driven VRF systems have the highest reliability rates in  
the industry and a leading customer service programme.  
High-efficiency operation  
A
GHP is no different in principle, however,  
developed by SANYO in 1980 the GHP outdoor unit  
13-25 HP models are equipped with a high-performance air  
exchanger and a newly developed refrigerant heat exchanger  
for high-efficiency operation, making them one of the most  
energy-efficient solutions on the market.  
is fitted with  
Natural gas or LPG, to drive the refrigerant compressor.  
a
combustion engine, powered by  
Variable capacity is achieved via the engine speed being  
altered up and down just as an inverter compressor speed  
is controlled in the electric VRF equivalent. The GHP  
therefore is an ideal solution where electrical power is at a  
premium (or no 3 phase available) however it also boasts  
a number of additional benefits/functions that are not  
available on an electric equivalent.  
Lowest nitrogen oxide emissions  
The GHP VRF systems have the lowest nitrogen oxide emissions,  
66% below the standard. In a pioneering development, the  
SANYO GHP features a brand new lean-burn combustion  
system that utilises air fuel ratio feedback control to reduce NOx  
emissions to an all-time low.  
The M Series of gas drivenVRF systems offers increased efficiency  
and performance across the range. Now more powerful than  
ever before, it can connect to up to 48 indoor units.  
Exhaust  
High efficiency heat exchanger  
Excellent economy  
Improvements include increased part load performance,  
reduced gas consumption with a Miller-cycle engine and  
reduced electrical consumption from using DC fan motors.  
TheMseries GHP continues to use ahybridheat exchanger for  
improved efficiency. By interlacing the refrigerant coil with the  
radiator carrying the coolant from the engine, the condensing  
capacity and radiator performance is balanced to an optimum  
level. This combination ensures the cooling efficiency drop in  
cold ambient is kept to a minimum, heating performance is  
down to -20oc and maintain a high COP.  
The SANYO GHP provides quick and powerful cooling/  
heating and increases delivery of heat into the space by the  
efficient recovery of heat from the engine cooling water,  
which is injected into the refrigerant circuit.  
Fan  
• Up to 71kW of cooling from a maximum running capacity of 5  
AMPs  
In addition, the use of engine waste heat ensures that our gas  
heat pump air conditioner requires no defrost cycle, therefore  
providing continuous 100% heating performance in severe  
weather conditions with an outside air temperature as low as  
-20°C. During cooling mode the rejected heat from the engine is  
available for use within a hot water system and can supply up to  
25kW of hot water at 75 °C.  
• Single phase power supply across the range  
• The option of natural gas or LPG as its main power source  
Higher engine efficiency  
Air  
• Free hot water! A water heat exchanger to connect to domestic  
hot water systems 13-25 HP (Heat Pump only)  
By utilising a Miler-Cycle engine, the compression stroke is  
reduced and therefore pumping losses are minimised. As a  
result the expansion volume ratio increases and the efficiency  
improves.  
• Option of DX or chilled water for indoor heat exchange  
• Option to connect to third party Air Handling Units  
• Reduced CO2 emissions  
High performance  
Miller cycle:This heat cycle has the characteristic that the closing  
time for the suction valve in regard to the base engine is late.  
As a result, the expansion stroke becomes relatively longer in  
comparison to the compression stroke.  
With its advanced heat exchanger design, this new GHP system  
offers improved efficiency and reduced running costs, which,  
coupled with improved engine management systems, have  
greatly improved the system COP rating.  
Accumulator  
Compressor  
Refrigerant heat exchanger  
New electrical power generator model  
By fitting a new plate heat exchanger the engine waste heat  
is recovered efficiently and reused to improve performance. In  
addition a proportionate control 3 way change over valve is used  
for control of the engine cooling water to increase efficiency in  
heating operation  
The biggest breakthrough in recent GHP technology is the  
launch of the ECO G Power, which provides 4.0kW of power.  
That’s enough electricity to power 8 computers or other  
applications.  
Power supply problems?  
If you are short of electrical power, gas heat pump  
could be the perfect solution.  
How a GHP works - High performance and low operating costs by using gas fuel  
• Runs on gas and just needs single phase supply.  
Cooling  
Heating  
• Enables the building’s electrical power supply to be  
used for other critical electrical demands.  
Refrigerant gas  
Refrigerant liquid  
GHP features at a glance  
• Power generation of up to 4kW on ECO G Power version  
Refrigerant  
liquid  
Cold air  
• Reduces capital cost to upgrade power substations  
to run heating and cooling systems.  
Refrigerant  
gas  
Up to 25kW hot water generation on all 2 pipe heat pump  
versions  
Outdoor unit  
Outdoor unit  
Heat  
Heat  
Warm air  
• Reduces power loadings within a building especially  
during peak periods.  
• Chiller module available for water based solutions  
• 100% heating performance even at -200c ambient  
• 180% indoor connectability (Single heat pump module)  
• Single phase power required through the range  
Warm air  
Hot water  
function  
Cold air  
Engine waste heat  
Discharge of heat  
Absorption of heat  
from the outside air  
by evaporation of  
refrigerant.  
absorbed from the  
inside of the room  
by liquefaction of  
refrigerant.  
• Electricity supply freed up for other uses such as IT  
servers, commercial refrigeration, manufacturing,  
lighting etc.  
Compressor  
Gas engine  
Compressor  
Gas engine  
Absorption of heat from the room by  
liquefaction of refrigerant.  
Discharge of heat generated by  
condensation of refrigerant.  
3
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
2
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
ECO G 3 Way Heat Recovery VRF System  
ECO G 3 Way Outdoor Unit Specifications  
HP  
Model  
16  
SGP-EZ150M2G2  
45.0  
20  
25  
SGP-EZ240M2G2  
71.0  
SGP-EZ190M2G2  
Cooling  
Heating  
Heating Low temp*  
Cooling  
Heating  
Cooling  
Heating  
Heating  
Cooling  
Heating  
AVE  
kW  
kW  
56.0  
63.0  
67.0  
1.35  
Still the only heat recovery (3 way) GHP system in  
Europe.  
Capacity  
Electricity  
Gas  
STD  
50.0  
53.0  
80.0  
75.0  
kW  
kW  
kW  
The new M Series ECO G 3 Way offers even more  
performance and outstanding features when you need  
simultaneous heating and cooling. Now with increased  
capacities available from 16HP to 25HP, SANYO offers the  
greatestchoiceandflexibilitytosolveanypowerproblemor  
site requirement.  
1.01  
1.54  
60.9  
58.0  
64.9  
1.14  
1.34  
1.24  
31.6  
36.1  
47.3  
1.37  
1.35  
1.36  
38.3  
43.0  
56.4  
1.41  
1.43  
STD  
LOW  
kW  
COP  
1.42  
Height  
Width mm  
Depth  
kg  
2,248  
1,800  
1,000 (+60)  
• Simultaneous heating and cooling for total control  
• Reduced gas consumption by Miller-cycle engine  
• Reduced electrical power consumption by using DC motors  
Size  
Weight  
Starter amperes  
845  
875  
A
30  
1 1/8 (28.58)  
7/8 (22.22)  
3/4 (19.05)  
R3/4 (bolt thread)  
ø 25 rubber hose  
58  
Gas  
Piping  
connection  
Discharge Inches (mm)  
• New lightweight design by use of aluminium engine block  
reduces weight by 110kg  
Liquid  
Pipe fuel gas  
Pipe exhaust drain  
Operation sound  
mm  
dB(A)  
57  
62  
• Part load efficiencies increased  
Comparison of the start times for heating operation  
Room temperature (˚C )  
Indoor/outdoor capacity ratio  
Number of indoor connections  
* 1: Low temp condition: Outdoor temperature 2 C˚.  
Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.  
Please refer to tube sizing charts for pipe selections and pipe length parameters.  
50-180% *1  
36  
• Connectability increased to up to 36 indoor units  
• Now available in 16, 20 and 25HP  
Gas heat pump  
• 200m maximum allowable piping length (L1) (equivalent - refer  
to technical manual)  
• Diversity ratio 50% - 130%  
Electric heat pump  
• Extended pipe runs (total 500m)  
• Silent mode offers a further 2dB(A) reduction  
Time axis (in case of the same load)  
Dimensions ECO G 3 Way (16-25HP)  
• 10,000 run hours between engine service intervals (equivalent  
Comparison of heating capacity  
Heating capacity (% )  
to one maintenance every 3.2 years*)  
Size (mm)  
Model Type  
150  
190 240  
ø28.58  
ø25.4  
ø19.05  
OD: ø25 Length: 200  
• Full heating capacity down to -20°C  
1
2
Suction refrigerant pipe  
Discharge refrigerant pipe  
Liquid refrigerant pipe  
Exhaust gas drain hose  
Inter-unit cable port  
Electrical power supply port  
Fuel gas port  
Service Clearances for installation  
ø22.22  
(Units: mm)  
• No defrost cycle  
* Assuming 3120 running hrs per year - 12 hrs x 5 days x 52 weeks  
Gas heat pump  
3
Top View  
at least  
100  
10  
4
at least  
100  
5
ø28  
ø28  
6
Rear  
Rear  
(refrigerant tubing)  
at least 2000  
7
G: R3/4  
ø20  
(refrigerant tubing)  
8
Condensation drain opening  
9
Rain and condensation outlet  
Engine exhaust outlet  
Suspension holes  
Anchor holes  
Electric heat pump  
10  
11  
12  
13  
14  
15  
at least  
350  
ECO G 3 Way is ideal for the following types of  
application:  
at least  
100  
at least  
4 - ø20  
4 - ø24  
350  
Front View  
Front View  
Segmented display  
Coolant intake (top)  
Vent  
(Single-unit installation)  
(Multi-unit series installation)  
• Office buildings with a diverse range of room temperatures  
Outside air temperature (˚C)  
14  
1000  
12  
400  
(anchor pitch)  
due to differing load profiles.  
1000 (external)  
ø736  
• Buildings with computer rooms requiring year round cooling.  
9
Additional parts  
By taking its power supply from the nearest indoor unit, the  
SANYO solenoid valve (change-over box) does not require any  
additional fused spur and at only 150mm high can be easily  
installed within a 200mm void space.  
7
15  
3
1
2
6
5
13  
11  
LPG option  
1030 (suspension holes)  
1060 (frame width)  
The option of using LPG as a power supply increases flexibility  
and avoids the problems of potential site restrictions in the  
future. The purer fuel is also excellent for further reductions  
in CO2 emissions - a fact recognised by the government.  
1800 (external)  
Front View  
271  
54  
4
147  
207  
242  
279  
312  
8
Rear View  
Left Side View  
5
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
4
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
ECO G 2 Way Heat Pump VRF System  
ECO G 2 Way Outdoor Unit Specifications  
Dimensions ECO G W-Multi 2 Way  
ECO G W-Multi for Heat Pump  
Applications  
Size (mm)  
Model Type  
120  
ø25.4  
ø12.7  
150 190 and 240  
ø28.58  
1
2
Gas refrigerant pipe (Gas tube)  
Liquid refrigerant pipe (Liquid tube)  
Refrigerant balance pipe (Balance tube)  
Exhaust gas drain hose  
Electrical power supply port  
Inter-unit cable port  
Fuel gas port  
ø15.88  
The new and improved  
M
Series heat pump  
Service Clearances for installation  
3
(Units: mm)  
ø9.52  
(2 Way) not only offers improved performance  
but also increased flexibility. Now available as  
multi-systems, many combinations are possible,  
from 13HP to 50HP, allowing for more power  
and enabling accurate matching of a system building  
load. Additional new features include part load engine  
management and compressor run hour equalisation.  
4
OD: ø25 Length: 200  
Top View  
at least  
100  
10  
at least  
100  
5
ø28  
ø28  
6
Rear  
Rear  
(refrigerant tubing)  
7
G: R3/4  
ø20  
at least 2000  
(refrigerant tubing)  
8
Condensation drain opening  
Rain and condensation outlet  
Engine exhaust outlet  
Suspension holes  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
at least  
350  
4 - ø20  
4 - ø24  
at least  
100  
at least  
Anchor holes  
350  
Front View  
Front View  
Segmented display  
Coolant intake (top)  
Vent  
(Single-unit installation)  
(Multi-unit series installation)  
Hot water intake  
Hot water outlet  
Cable inlet for interlock and the like  
Rp3/4  
Rp3/4  
ø28  
14  
1000  
• Reduced gas consumption by Miller-cycle engine  
12  
400  
(anchor pitch)  
1000  
ø736  
• Reduced electrical power consumption by using DC motors  
• New lightweight design by use of aluminium engine block  
reduces weight by 110kg  
9
3
7
• Part load efficiencies increased  
2
• Silent mode offers a further 2dB(A) reduction  
• Chiller option  
1
• Connectability increased - now up to 48 indoor units  
• Multi-systems with combinations from 13HP up to 50HP  
18  
15  
12  
6
5
17  
16  
- 13HP (25kW cooling - 30kW heating)  
- 25HP (56kW cooling - 67kW heating)  
• 200m maximum allowable piping length (L1) (equivalent - refer  
to technical manual)  
11  
• 10,000 run hours between engine service intervals (equivalent  
• Diversity ratio 50-180%  
to one maintenance every 3.2 years*)  
1040  
1060  
1800  
271  
4
54  
• Extended pipe runs (total 500m)  
• Industry leading sound levels  
• Full heating capacity down to -20°C  
147  
207  
242  
275  
312  
461  
8
Rear View  
Front View  
Left Side View  
• No defrost cycle  
* Assuming 3120 running hrs per year - 12 hrs x 5 days x 52 weeks  
HP  
13  
16  
20  
25  
26  
29  
32  
33*  
36*  
40*  
45*  
50  
SGP-EW120M2G2W  
SGP-EW150M2G2W  
SGP-EW190M2G2W  
SGP-EW240M2G2W  
SGP-EW120M2G2W  
SGP-EW120M2G2W  
SGP-EW120M2G2W  
SGP-EW150M2G2W  
SGP-EW150M2G2W  
SGP-EW150M2G2W  
90.00  
SGP-EW120M2G2W  
SGP-EW190M2G2W  
SGP-EW150M2G2W  
SGP-EW190M2G2W  
101.00  
SGP-EW190M2G2W  
SGP-EW190M2G2W  
112..0  
SGP-EW190M2G2W  
SGP-EW240M2G2W  
127.00  
SGP-EW240M2G2W  
SGP-EW240M2G2W  
142.00  
Model name  
Cooling  
Heating  
Heating Low temp*1 kW  
kW  
35.50  
40.00  
42.50  
12.00  
0.85  
45.00  
50.00  
53.00  
16.00  
56.00  
63.00  
67.00  
20.00  
1.35  
71.00  
80.00  
80.50  
90.00  
95.50  
28.00  
2.20  
91.50  
103.00  
109.50  
32.00  
2.20  
STD  
100.00  
106.00  
32.00  
113.00  
120.00  
36.00  
126.00  
134.00  
40.00  
143.00  
142.00  
45.00  
160.00  
150.00  
50.00  
Capacity  
75.00  
25.00  
85.00  
24.00  
1.70  
Hot water  
Cooling  
Heating  
Cooling  
Heating  
Heating  
Cooling  
Heating  
AVE  
kW  
2.70  
2.70  
Electricity  
1.01  
31.60  
36.10  
47.30  
1.37  
1.54  
60.90  
58.00  
64.90  
1.14  
2.02  
2.55  
99.20  
101.00  
121.30  
1.25  
3.08  
121.80  
116.00  
129.80  
1.14  
kW  
kW  
24.50  
28.10  
36.80  
1.40  
1.37  
1.39  
38.30  
43.00  
56.40  
1.41  
1.43  
1.42  
49.00  
56.20  
73.60  
1.40  
1.37  
1.39  
56.10  
64.20  
84.10  
1.38  
1.36  
1.37  
63.20  
72.20  
94.60  
1.37  
1.35  
1.36  
62.80  
71.10  
93.20  
1.41  
1.41  
1.41  
69.90  
79.10  
103.70  
1.39  
1.39  
1.39  
76.60  
86.00  
112.80  
1.41  
1.43  
1.42  
Gas consumption  
STD  
LOW  
COP  
1.35  
1.36  
1.34  
1.24  
1.38  
1.31  
1.34  
1.24  
Max COP (inc hot water) Cooling  
Size  
1.87  
1.85  
1.92  
1.54  
1.87  
1.86  
1.85  
1.90  
1.89  
1.92  
1.69  
1.54  
Height  
2,248  
Width mm  
Depth  
kg  
1,800  
1,800 + 100 (min distance) + 1,800 (in a straight installation)  
1,610  
1,000 (+60)  
1,580  
30  
Weight  
Starter amperes  
Gas  
790  
820  
850  
1,640  
1,670  
1,700  
(A)  
1 1/8 (28.58)  
1 3/8 (34.92)  
1 5/8 (41.27)  
Piping connection  
Liquid  
Balance  
Inches (mm)  
dB(A)  
1/2 (12.7)  
57  
5/8 (15.88)  
3/4 (19.05)  
3/8 (9.52)  
Pipe fuel gas  
Pipe exhaust drain  
Operation sound  
Indoor/outdoor capacity ratio  
Number of indoor connections  
R3/4 (bolt thread)  
ø25 rubber hose  
60  
58  
36  
62  
61  
63  
65  
50-180 %  
50-130 %  
48  
32  
* In case of these combinations EGW190M2G2W is able to connect as W-multi instead of EW190M2G2w.  
* 1: Low temp condition: Outdoor temperature 2 C˚.  
Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.  
Please refer to tube sizing charts for pipe selections and pipe length parameters.  
Capacity Hot Water is available when outside ambient air temperature is above 7C˚.  
7
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
6
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
ECO G Power - GHP with electricity generation  
& hot water supply  
HP  
20  
33  
SGP-EW120M2G2W  
SGP-EGW190M2G2W  
91.50  
36  
SGP-EW150M2G2W  
SGP-EGW190M2G2W  
101.00  
40  
SGP-EGW190M2G2W  
SGP-EGW190M2G2W  
112.00  
45  
SGP-EGW190M2G2W  
SGP-EW240M2G2W  
127.00  
NEW  
NEW 2 way gas driven VRF with electrical  
power generator  
SGP-EGW190M2G2W  
Model  
Cooling  
Heating  
Heating Low temp*1 kW  
kW  
56.0  
63.0  
67.0  
22.0  
STD  
103.0  
109.50  
34.0  
113.00  
120.00  
38.0  
126.00  
134.00  
44.0  
143.00  
142.00  
47 .00  
Capacity  
Hot water  
SANYO’s ECO  
G
Power is  
a
revolution in air  
permanent  
Power generater capacity at  
rating  
kW  
DC 2.5 (Max 4.3)  
conditioning design. Fitted with  
a
High power  
engine  
Cooling  
Heating  
kW  
kW  
kW  
1.35  
1.01  
44.0 (38.3)*  
48.7 (43.0)*  
2.20  
2.70  
magnet, non-bearing type generator, it is the first  
VRF system that can supply heating, cooling, hot  
water and now also a supply of electrical power.  
Electricity  
Power generator  
• permanent  
magnet type  
• non-bearing  
2.02  
75.60  
84.80  
2.55  
Cooling  
68.50  
76.80  
88.00  
97.40  
104.90  
101.00  
Line linkage  
inverter  
Heating STD  
Heating  
Gas consumption  
kW  
62.1 (56.4)*  
98.90  
1.31  
1.81  
109.40  
124.20  
121.30  
Each ECO G Power unit has a 4.0kW generator, which  
provides enough electricity to power 8 computers or  
other applications.  
LOW  
Double clutch  
compressor  
Cooling  
1.33 (1.41)*  
1.34 (1.43)*  
1.34 (1.42)*  
1.29  
1.30  
1.23  
1.27  
1.25  
1.18  
1.38  
1.28  
COP Air conditioning only Heating  
AVE  
Max COP (Inc generater, hot water)  
Cooling  
1.30  
• Innovative technology that reduces CO2 emissions by up to  
30%  
1.78  
1.80  
1.78  
1.69  
Height  
2,248  
Height  
Width  
Depth  
mm  
1,800  
875  
1,800 + 100 (Min distance) + 1,800  
• Heat pump air conditioning system providing cooling  
or heating  
1,000 (+60)  
1,685  
Production of electricity  
Weight  
Starter amperes  
Gas  
kg  
A
1,660  
1,740  
1,720  
30  
Generates from 2kW to 4kW depending on air conditioning  
1 1/8 (28.58)  
5/8 (15.88)  
1 3/8 (34.92)  
1 5/8 (41.27)  
• Can provide both electricity and hot water in heating and  
cooling mode  
Pipe  
Liquid  
Balance  
Pipe fuel gas  
Inches (mm)  
3/4 (19.05)  
load  
4.5  
4
3/8 (9.52)  
R3/4 (bolt, thread)  
ø25 rubber hose  
61  
• Up to 4kW electricity generated  
• Very efficient generator  
Pipe exhaust drain port  
Operation sound  
Indoor/outdoor capacity ratio  
Number of indoor connections*  
mm  
dB(A)  
58  
32  
63  
3.5  
3
50-130%  
48  
• Hot water provided when cooling or heating when outside  
ambient air temperature is above 7°C  
2.5  
2
Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.  
Please refer to tube sizing charts for pipe selections and pipe length parameters.  
Capacity Hot Water is available when outside ambient air temperature is above 7˚C.  
• 22kW hot water generation capacity  
1.5  
1
• 20HP model provides 56kW cooling or 63kW heating  
• Can connect to up to 36 indoor units  
Dimensions ECO G Power  
0.5  
0
Size (mm)  
ø28.58  
ø15.88  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
• 200m maximum allowable piping length (L1) (equivalent - refer  
to technical manual)  
1 Gas refrigerant pipe (Gas tube)  
Liquid refrigerant pipe (Liquid tube)  
3
Air conditioning load (%)  
2
Refrigerant balance pipe (Balance tube) ø9.52  
Service Clearances for installation  
OD:  
(Units: mm)  
4
Exhaust gas drain hose  
Generate electricity during heating or cooling  
operation  
Length:  
• IU/OU capacity ratio 50 - 130%  
5
6
Electrical power supply port  
Inter-unit cable port  
Inverter cable port  
Inverter cable port  
Fuel gas port  
ø28  
ø28  
ø28  
ø40  
at least  
100  
at least  
100  
at least  
350  
Top View  
12  
7
at least 2000  
Rear  
(refrigerant tubing)  
Rear  
(refrigerant tubing)  
8
Generate electricity and air conditioning (heating or cooling)  
at the same time by using remaining engine power. ECO G  
Power can generate from 2.3 to 4.0kW electricity at a generation  
efficiency of more than 40%.  
9
G: R3/4  
ø20  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
Condensation drain opening  
Rain and condensation outlet  
Engine exhaust outlet  
Suspension holes 4-ø20  
Anchor holes 4 - ø24  
Segment display  
Coolant intake (top)  
Vent  
Hot water intake  
at least  
100  
at least  
350  
Front View  
Front View  
(Single-unit installation)  
(Multi-unit series installation)  
1000 (external)  
ø736  
Rp3/4  
Rp3/4  
1000  
14  
16  
(anchor pitch)  
400  
Hot water outlet  
11  
17  
9
8
7
5
6
3
1
19  
18  
13  
15  
2
1040 (suspension holes)  
1100 (frame width)  
4
271  
54  
1800 (external)  
Front View  
10  
147  
207  
242  
275  
Rear View  
Left Side View  
312  
461  
9
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
8
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
Additional GHP Functions  
GU Type Heat Exchanger & CFR Units  
SANYO’s new heat recovery ventilation system allows  
total control via a system network whilst modulating the  
temperature and humidity of incoming air supply.  
GHP Chiller available with outdoor unit capacities from 71kW  
• Integration of heat recovery ventilation and DX coil technology  
for optimum air temperature control  
Water Heat Exchanger  
• Connects to all ECO & GHP outdoor units with a filter option  
• 3 Way: Solenoid valve kit is required for each unit  
Duct  
Water Piping  
• 2 Way: RAP kit is required for each unit  
Indoor unit specifications  
Model Name  
SPW-GU055XH  
SPW-GU075XH  
750  
220/230/240V, 1 phase - 50 Hz  
8.2 (2.6)*1  
SPW-GU105XH  
Air circulation (H) m3/h  
Power source  
500  
1,000  
Outdoor unit  
Air Handling Unit  
UK Cooling  
kW  
kW  
5.3 (1.7)*1  
6.5 (2.3)*1  
10.7 (3.4)*1  
12.6 (4.6)*1  
Fresh air load  
Model No.  
SGP-WE80M1  
SGP-WE170M1  
treatment capacity  
The SANYO ECO G Water Heat Exchanger can provide  
water at a wide range of temperatures suitable for a  
variety of commercial applications ranging from comfort  
air conditioning to food processing or the replacement of  
boilers and other systems.  
UK Heating  
UK Cooling  
UK Heating  
9.8 (3.5)*1  
Cooling capacity  
Heating capacity  
Cooling capacity  
Heating capacity  
Cooling capacity  
Heating capacity  
Cooling capacity  
Heating capacity  
kW  
kW  
kW  
kW  
kW  
kW  
kW  
kW  
25  
30  
25  
30  
25  
30  
25  
30  
30  
35.5  
37.5  
45  
50  
60  
%
%
59  
Enthalpy exchange  
efficiency  
SGP-EW120M2G2W  
67  
75  
Temp exchange efficiency  
SGP-EW150M2G2W  
kW  
BTU/h  
kW  
kW  
Amps  
Amps  
3.6  
12,000  
0.532  
0.532  
2.4  
5.6  
7.3  
25,000  
0.798  
0.798  
3.5  
Equivalent cooling capacity  
SGP-EW190M2G2W and  
SGP-EGW190M2G2W  
19,000  
0.737  
0.737  
3.2  
Cooling  
Power input  
56  
67  
• New 25 kW and 50 kW capacity models  
Heating  
SGP-EW240M2G2W  
Cooling  
Running current  
Heating  
Cooling power input kW  
Heating power input kW  
0.01  
0.01  
• In cooling (chiller) mode provides water from -15°C to 15°C  
2.4  
3.2  
3.5  
Electrical rating  
Power supply  
Type  
Sirocco fan  
221 (188)  
264 (218)  
• In heating mode can provide hot water up to 55°C, for example  
for under floor heating applications  
220/230/240V Single Phase 50Hz  
External static pressure-return air  
External static pressure-supply air  
Output  
Pa  
Pa  
kW  
db(A)  
mm  
183 (170)  
205 (182)  
0.28 (4P)x2  
46 (Cooling), 47 (Heating)  
135 (88)  
176 (137)  
Fan motor  
Height  
Width  
Depth  
mm  
mm  
mm  
kg  
1,000  
550  
965  
Size  
0.35 (4P)x2  
Sound pressure level (C/H)  
Height  
Width  
Depth  
Liquid (flare)  
Piping connections Gas (flare)  
Drain piping  
Connection duct diameter  
Net weight  
47 (Cooling), 48 (Heating)  
48 (Cooling), 49 (Heating)  
1220  
• Includes water flow protection to prevent freezing  
• Temperature sensor included  
Weight  
125  
4.3  
8.5  
0.01  
0.28  
ø22.22  
ø9.52  
160  
8.6  
11.3  
0.02  
0.50  
425  
1785  
1000  
450  
1903  
Standard cold/hot water flow rate  
Hydrostatic loss  
Holding water quantity inside the unit  
Minimum holding water quantity outside the unit m3  
m3/h  
kPa  
m3  
Dimensions  
mm  
mm  
mm (inches)  
mm (inches)  
1120  
• S-Link communication is connectable with any controllers  
6.35 (1/4)  
12.7 (1/2)  
VP-25  
Gas pipe  
mm  
ø28.58  
ø15.88  
• Split system means reduced installation cost and the use of a  
less powerful circulation pump  
Piping refrigerant  
Liquid pipe  
mm  
mm  
kg  
250  
300  
168  
Heat exchanger  
hot/cold heat exchanger  
0.686  
Protective thermostat  
134  
153  
Water circuit limit pressure  
MPa  
The values in ( ) for the external static pressure and operating sound are for use of booster cable. *1: Heat recovery capacity by heat exchanger. Data subject to change without notice.  
One touch changeover between cooling and heating operation  
Anti-freezing protection system  
Specifications subject to change without notice.  
The CFR- PHE uses a unique purifying Bioxigen system to  
produce negative ions this can reduce pollutants by up to  
85% whilst improving, significantly air quality within most  
environments.  
• The system can accommodate up to 120m (actual length) of  
piping between the outdoor unit and the water heat exchanger,  
allowing flexibility of installation location  
Heating  
(standard)  
Outlet 45°C  
Heating  
Operating condition  
Cooling  
(low temperature)  
Outlet 45°C  
2°C DB, 1°C WB  
Water temperature of water heat exchanger unit Outlet 7°C  
Outdoor side intake air temperature  
35°C DB 7°C DB, 6°C WB  
• High efficiency heat exchanger & Easy to clean filters  
• The system uses antifreeze coolant, so it can produce cold water  
even at -15°C, thereby complying with “brine specifications”  
Note: The gas consumption can be 110% of the specification value depending on the  
operating conditions.  
The CFR-PHE unit structure is constructed from Aluzink frame  
The high efficiency low pressure loss total heat exchanger  
is made of specially treated paper to enable the unit to be  
as efficient as 76% during normal operation. This allows  
system to recover both latent and sensible heat.  
work and galvanised steel with 20 mm thick fire resistant  
acoustic insulation, reducing both weight and sound levels to  
a minimum. The system is supplied with ducted spigots which  
can be positioned either at the front or side of the unit to ease  
installation.  
Hot water supply function (during cooling or heating operation)  
SGP-EW120M2G2W  
SGP-EW150M2G2W  
SGP-EW190M2G2W  
SGP-EW240M2G2W  
SGP-EGW190M2G2W  
The engine waste heat, which is normally exhausted into  
the atmosphere, is recovered via the heat exchanger and  
effectively used as hot water, so the GHP system acts as a  
subsystem that alleviates the load on the client’s main hot  
water system and therefore offers “freehot water.  
Water heating capacity up to 65 kW (of 75°C hot water)  
Hot water piping allowable pressure 0.7 MPa  
Hot water circulation rate 2 - 3.9m3/h  
Indoor unit specifications  
Model CFR/ CFR-PHE  
33  
55  
110  
175  
220  
Nominal air flow *  
External Static Pressure  
Sound Pressure **  
Fans  
m3/hr  
pa  
dB(A)  
300  
45  
43  
620  
55  
920  
65  
1580  
70  
1850  
77  
Hot water pipe size 3/4 inch  
51  
50  
53  
52  
System configured at site  
Power in  
Absorbed power  
Fan speeds  
Watts  
A
no  
184  
0.75  
340  
1.8  
294  
2.2  
700  
4.4  
3
700  
4.8  
1
Insulation Class  
F
Electrical supply  
Bioxigen Elements (PHE only)  
Number of elements  
Electrical supply  
Power in  
v/ph/htz  
230/1/50  
GHP  
Hot Water  
Storage  
Tank  
Main  
Hot Water  
Boiler  
OUT  
IN  
Hot water inlet: Rø3/4  
Hot water outlet: Rø3/4  
2 X C  
2 X F  
v/ph/htz  
Watts  
230/1/50  
8
8
8
8
8
Filter  
EU3  
Paper Heat Exchanger  
Temperature Efficiency heating ***  
Temperature Efficiency cooling ****  
CFR-PHE  
Water piping  
76%  
62%  
74%  
60%  
72%  
58%  
68%  
54%  
73%  
59%  
* Nominal air flow ** Sound pressure 1.5 mts from the unit in free field *** Data referred to -50C 80% RH OAT room condition 200C 50% RH **** Data referred to 320C 50% RH OAT room condition 260C 50% RH  
10  
11  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
VRF Indoor Unit Range for ECOi and GHP  
Self-diagnosing function  
Mild dry  
Wider operation  
Automatic fan operation  
Air Sweep  
Comfortable auto-flap control  
Built-in drain pump  
Automatic restart function for power failure  
Model size  
Capacity  
7
9
12  
16  
18  
22  
25  
36  
48  
60  
76  
96  
Wireless remote control  
Cooling  
Heating  
Cooling  
Heating  
2.2  
2.5  
7,500  
8,500  
SPW-X075XH  
2.8  
3.2  
9,600  
11,000  
SPW-X095XH  
3.6  
4.2  
12,000  
14,000  
SPW-X125XH  
4.5  
5.0  
15,000  
17,000  
SPW-X165XH  
5.6  
6.3  
19,000  
21,000  
SPW-X185XH  
6.4  
7.0  
22,000  
24,000  
7.3  
8.0  
25,000  
27,000  
SPW-X255XH  
10.6  
11.4  
36,000  
39,000  
14.0  
16.0  
47,800  
54,600  
16.0  
18.0  
54,600  
61,500  
SPW-X605XH  
22.4  
25.0  
76,400  
85,300  
28.0  
31.5  
95,500  
107,500  
kW  
Built-in infra red  
sensor  
Separate infra red  
sensor  
Functions  
Capacity BTU/h  
SPW-X365XH  
SPW-X485XH  
SPW-XDR74GXH56B SPW-XDR94GXH56B SPW-XDR124GXH56B SPW-XDR164GXH56B SPW-XDR184GXH56B  
SPW-XDR254GXH56B  
Panel  
PNR-XD484GHAB  
SPW-XDR364GXH56B SPW-XDR484GXH56B SPW-XDR604GXH56B  
X Type  
Panel  
Panel  
Panel  
Panel  
Panel  
Panel  
Panel  
Panel  
Semi-Concealed  
Cassette  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
PNR-XD484GHAB  
SPW-XM075XH  
Panel  
PNR-XM185  
SPW-XM095XH  
Panel  
PNR-XM185  
SPW-XM125XH  
Panel  
PNR-XM185  
SPW-XM165XH  
Panel  
PNR-XM185  
SPW-XM185XH  
Panel  
PNR-XM185  
XM Type  
Semi-Concealed  
SPW-US075XH  
SPW-US095XH  
SPW-US125XH  
SPW-US165XH  
SPW-US185XH  
US Type  
Concealed Duct  
SPW-U075XH  
SPW-UR74GXH56B  
SPW-U095XH  
SPW-U125XH  
SPW-U165XH  
SPW-U185XH  
SPW-U255XH  
SPW-U365XH  
SPW-U485XH  
SPW-U605XH  
SPW-UR94GXH56B SPW-UR124GXH56B SPW-UR164GXH56B SPW-UR184GXH56B  
SPW-UR254GXH56B  
SPW-UR364GXH56B SPW-UR484GXH56B SPW-UR604GXH56B  
U Type  
Concealed Duct  
25,48 type  
SPW-DR364GX-  
SPW-DR484GX-  
SPW-DR764GX-  
SPW-DR964GX-  
DR Type  
Concealed  
Duct  
SPW-DR254GXH56B  
H56B  
H56B  
H56B  
H56B  
76,96 type  
SPW-K075XH  
SPW-K095XH  
SPW-K125XH  
SPW-T125XH  
K Type  
Wall Mounted Unit  
SPW-KR164GXH56B SPW-KR184GXH56B  
SPW-KR254GXH56B  
KR Type  
Wall Mounted Unit  
SPW-T165XH  
SPW-T185XH  
SPW-T225XH  
SPW-TDR254GXH56B  
SPW-T365XH  
SPW-TDR364GXH56B SPW-TDR484GXH56B  
SPW-T485XH  
SPW-TDR124GXH56B SPW-TDR164GXH56B SPW-TDR184GXH56B  
T Type Ceiling-  
Mounted Unit  
FTR Type  
Floor/Ceiling  
Mounted Units  
SPW-FTR74EXH56B SPW-FTR94EXH56B SPW-FTR124EXH56B SPW-FTR164EXH56B SPW-FTR184EXH56B SPW-FTR224EXH56B  
SPW-FUR74EXH56B SPW-FUR94EXH56B SPW-FUR124EXH56B SPW-FUR164EXH56B SPW-FUR184EXH56B SPW-FUR224EXH56B  
FUR Type  
Floor/Ceiling  
Slim Concealed Duct  
SPW-FR74GXH56B  
SPW-FR94GXH56B  
SPW-FR124GXH56B SPW-FR164GXH56B SPW-FR184GXH56B  
SPW-FR254GXH56B  
FR Type Floor  
Standing Unit  
SPW-FMR124GX-  
SPW-FMR164GX-  
SPW-FMR184GX-  
SPW-FMR254GX-  
FMR Type  
Concealed Floor  
Standing Unit  
SPW-FMR74GXH56B SPW-FMR94GXH56B  
SPW-ADR74GXH56B SPW-ADR94GXH56B  
Panel  
PNR-AD124GHB  
H56B  
H56B  
H56B  
H56B  
SPW-ADR124GX-  
H56B  
ADR Type  
Semi-Concealed  
Cassette 1-Way  
Air Discharge  
Panel  
PNR-AD124GHB  
Panel  
PNR-AD124GHB  
SR Type  
SPW-SR74GXH56B  
Panel  
PNR-S124GHB  
SR94GXH56B  
Panel  
PNR-S124GHB  
SR124GXH56B  
Panel  
PNR-S124GHB  
SR164GXH56B,  
Panel  
PNR-S124GHB  
SR184GXH56B  
Panel  
PNR-S124GHB  
SPW-SR254GXH56B  
Panel  
PNR-S253GHANB  
Semi-Concealed  
Cassette 2-Way  
Air Discharge  
SPW-LDR94GXH56B SPW-LDR124GXH56B SPW-LDR164GXH56B SPW-LDR184GXH56B  
Panel  
PNR-LD254GHAB  
SPW-LDR254GXH56B  
Panel  
PNR-LD254GHAB  
LDR Type  
Semi-Concealed  
Slim Cassette  
Panel  
PNR-LD254GHAB  
Panel  
PNR-LD254GHAB  
Panel  
PNR-LD254GHAB  
GU Type  
Total Heat  
Exchanger  
SPW-GU055XH  
SPW-GU075XH  
SPW-GU105XH  
13  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
12  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
Individual Control Systems Overview  
Centralised Control Systems Overview  
A wide variety of control options to meet the requirements of different customers.  
Operation system  
Individual control systems  
Timer operation  
Centralised control systems  
Simplified charge ratio for each tenant  
Operation with various  
Only ON/OFF operation  
function from central  
from central station  
station  
Normal  
Operation from  
each seat  
Daily and  
Requirements  
Simple operation  
operation  
weekly programme  
Personal computer  
Touch screen panel  
(field supply)  
External appearance  
External appearance  
Web  
application  
Wireless remote  
controller  
RCS-SH80BG.WLB  
RCS-TH80BG.WLB  
RCS-BH80AG.WLB  
RCS-TRP80BG.WLB  
RCS-SH1BGB  
Simplified remote  
controller  
Timer wired  
Schedule timer  
SHA-TM64AGB  
remote controller  
System controller  
SHA-KC64AGB  
ON/OFF controller  
SHA-KC16KAGB  
Intelligent controller  
Communication adaptor  
Type, model name  
Type, model name  
RCS-TM80BG  
SHA-KT256EG  
SHA-KA128AGB  
RCS-KR1EG  
Number of indoor units  
which can be controlled  
64 groups,  
1 group, 8 units  
1 group, 8 units  
1 group, 8 units  
Number of indoor units which  
can be controlled  
64 groups,  
16 groups,  
64 units x 4 systems,  
max. 256 units  
2 systems,  
max. 64 units  
max. 64 units  
max. 64 units  
max. 128 units  
Power supply from the  
system controller.  
Up to 10 units can be  
connected to one system.  
Main unit/sub unit (1  
main unit + 1 sub unit)  
connection is possible.  
Up to 8 units (4 main  
units + 4 sub units) can be  
connected to one system.  
Use without remote  
controller is impossible.  
When there is no system  
controller, connection is  
possible to the T10 terminal  
of an  
A communication adaptor  
(SHA-KA128AGB) must be  
installed for three or more  
systems.  
Up to 2 units can be  
connected per group.  
Up to 2 units can be  
connected per group.  
Up to 2 units can be  
connected per group.  
Maximum 500 indoor  
units (128 per communica-  
tion adaptor)  
Use limitations  
Use limitations  
Use without remote  
controller is possible.  
indoor unit.  
Connectable  
indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
Connectable  
indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
4 series indoor unit  
Function  
Function  
ON/OFF  
-
-
-
-
-
-
ON/OFF  
Mode setting  
Fan speed setting  
Mode setting  
Fan speed setting  
-
-
-
-
*1  
*1  
*1  
Temperature setting  
Air flow direction  
Temperature setting  
Air flow direction  
*1  
*1  
*1  
Permit/Prohibit switching  
Weekly programme  
-
-
-
Permit/Prohibit switching  
Weekly programme  
-
-
-
*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)  
15  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  
14  
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB  

Oreck Airp Series User Manual
Panasonic 58 Ghz Expandable Digital Cordless Answering System Kx Tg6074 User Manual
Panasonic Cs C28cku User Manual
Panasonic Cw A90vr User Manual
Panasonic Uf 7100 User Manual
Precisionaire Crank Lock Hepa Filter Housing C 4 User Manual
Rena Da615 User Manual
Ricoh Ld435c User Manual
Samsung As18hpan User Manual
Sharp Fo 3800m User Manual