Samsung Uq18a9 0 Rcf User Manual

OWNER’S INSTRUCTIONS  
MANUAL DE INSTRUCCIONES  
MANUEL D’UTILISATION  
Indoor Unit  
Outdoor Unit  
UQ09A5(6)MAF  
UQ12AA(B)MCF  
UQ18A9(0)RCF  
UQ18A9(0)RCFD  
UQ24A1(2)RC  
AQ09A5(6)MAF  
AQ12AA(B)MCF  
AQ18A9(0)RCF  
AQ18A9(0)RCFD  
AQ24A1(2)RC  
AQ24A1(2)RCD  
UQ24A1(2)RCD  
Split-type Room Air Conditioner (Cool and Heat)  
Aire acondicionado doméstico sistema Split (Refrigeración y Calefacción)  
Climatiseur de type Séparé (Refroidissement et Chauffage)  
E
S
F
DB98-15773A(4)  
Contents  
PREPARING YOUR AIR CONDITIONER  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . 6  
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . 8  
Installing the Remote Control Holder . . . . . . . . . . . . . . . . . . . . 8  
OPERATING YOUR AIR CONDITIONER  
5 Way Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
9
Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . 10  
Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Heating Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
Changing the Room Temperature Quickly . . . . . . . . . . . . . . . 13  
Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . 16  
Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . 17  
PROGRAMMING YOUR AIR CONDITIONER  
Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
RECOMMENDATIONS FOR USE  
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . 22  
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . 23  
Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
Installing a Filter (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
TECHNICAL SPECIFICATIONS  
E-3  
View of the Unit  
The design and shape are subject to change according to the model.  
Indoor Unit  
Air filter  
Air flow blades (outlet)  
Air Inlet  
(under the grille)  
Timer indicator  
Remote Control Sensor  
SAVING indicator  
STANDARD indicator  
NATURE indicator  
SILENCE indicator  
POWER indicator  
ON/OFF & 5 Way  
selection button  
No t e  
For details on the 5 Way, refer to page 9.  
E-4  
Outdoor Unit UQ09A5(6)MAF  
Air Inlet(Rear)  
Air Outlet  
Connection Valve  
Outdoor Unit  
UQ12AA(B)MCF  
Air Inlet(Rear)  
Air Outlet  
Connection Valve  
Outdoor Unit  
UQ18A9(0)RCF  
UQ18A9(0)RCFD  
Air Inlet(Rear)  
UQ24A1(2)RC  
Air Outlet  
Connection Valve  
Outdoor Unit  
UQ24A1(2)RCD  
Air Inlet(Rear)  
Air Outlet  
Connection Valve  
E-5  
Remote Control - Buttons and Display  
Remote control  
Mode selection button  
(AUTO, COOL, DRY, FAN, HEAT)  
transmission indicator  
Operating mode  
(
AUTO,  
COOL,  
DRY,  
FAN,  
HEAT)  
Temperature adjustment  
buttons  
Temperature setting  
Turbo mode  
Sleep mode  
Turbo/Sleep mode  
selection button  
Fan speed  
Fan speed adjustment  
button  
Air flow direction  
Swing button  
On Timer setting  
On Timer button  
Off Timer setting  
Off Timer button  
Battery discharge indicator  
ON/OFF &  
Timer Set/Cancel button  
5 Way selection button  
E-6  
Getting Started  
You have just purchased a split type air conditioner and it has been  
installed by your installation specialist.  
Your Ow ners Instructions contains valuable inform ation on using your  
air conditioner. Please take the tim e to read it as it w ill help you take full  
advantage of the units features.  
The booklet is organized as follow s.  
The follow ing figures are show n on pages from 4 to 6 :  
-
-
Indoor and outdoor units  
Rem ote control(buttons and display)  
They w ill help you find the buttons and understand the sym bols displayed.  
In the m anual, you w ill find a series of step-by-step procedures for each  
function available.  
The illustrations in the step-by-step procedures use three different sym bols:  
PRESS  
PUSH  
HOLD DOWN  
E-7  
Inserting the Remote Control Batteries  
You m ust insert or replace the rem ote control batteries w hen :  
You purchase the air conditioner  
The rem ote control does not w ork correctly  
No t e  
Use two AAA, LR03 1.5V batteries.  
Do not use old batteries or different kinds of batteries together.  
Batteries may be completely discharged after 12 months, even  
if they have not actually been used.  
1
2
Push the battery cover on the rear of the remote control with your thumb  
in the direction of the arrow and remove it.  
Insert the two batteries, taking care to respect the polarities :  
+ on the battery with + on the remote control.  
- on the battery with - on the remote control.  
3
Close the cover by sliding it back until it clicks into place.  
Installing the Remote Control Holder  
1
2
Place the remote control holder on the wall.  
Fix the remote control holder by tightening the screws.  
3
Put the remote control into the holder as shown in the figure.  
If you want to install the holder easily, you had better install the holder  
on the wooden frame.  
E-8  
5 Way Function  
You can select the 5 Way function with operating mode of the air conditioner for  
more comfortable circumstances. You can use the 5 Way function with the indoor  
unit as well as the remote control. Thus, you can use this function  
even though you have lost your remote control.  
Using with the indoor unit  
1
Press the  
mode.  
(On/Off) button one time and then select the desired  
To obtain a(n)...  
Then select...  
(STANDARD) mode  
Normal operating  
Reducing the uncomfortable  
temperature gradually  
(NATURE) mode  
High fan speed  
(POWER) mode  
(SAVING) mode  
(SILENCE) mode  
Compressor run time reduced  
Fan speed reduces as the temperature  
decreases  
2
To stop the operating, press the  
turn off.  
(On/Off) button until all indicators  
No t e  
Even if the air conditioner has been turned on via the  
(On/Off  
)
button on the unit, operations can still be controlled  
using the remote control as usual.  
Selecting with the Remote Control  
To select the 5 Way function with the remote control, press the  
button one or more times until the desired mode is selected.  
Each time you press the  
button:  
Each 5 Way indicator on the indoor unit lights up in order.  
E-9  
Selecting the Automatic Operating Mode  
You can start the air conditioner in Autom atic m ode from your rem ote  
control. In the Autom atic m ode, the standard tem perature and the  
optim um fan speed is selected autom atically. You can adjust the  
standard tem perature but not the fan speed.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the  
button on the remote control one or more times until it appears.  
Result:  
The indoor unit beeps each time you press the  
button.  
The air conditioner runs in AUTO mode.  
No t e  
You can change modes at any time.  
3
To adjust the standard temperature (The air conditioner automatically  
set the standard temperature by the current room temperature.),  
press the  
buttons one or more times.  
SET TEMP. SET TEMP.  
-4°F -2°F  
< When you feel hot >  
-
SET TEMP. SET TEMP.  
+2°F +4°F  
< When you feel chilly >  
Standard temperature  
E-10  
Cooling Your Room  
You m ust select the Cool m ode if you w ish to adjust the:  
Cooling tem perature  
Fan speed w hen cooling  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in COOL mode.  
button.  
No t e  
You can change modes at any time.  
3
To adjust the temperature, press the  
buttons one or more times  
until the required temperature is displayed.  
Possible temperatures are between 65°F(18°C) and 86°F(30°C)  
inclusive.  
Result:  
Each time you press the  
buttons:  
- The temperature is adjusted by 1°F  
- The indoor unit beeps  
The air conditioner starts cooling, provided that the room  
temperature is higher than the selected temperature;  
the fan will, however, operate.  
4
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
)
Automatic (rotated :  
Low  
Medium  
High  
Result:  
Each time you press the  
button, the indoor unit beeps.  
5
To control the direction of the air flow, refer to page 16 and 17.  
E-11  
Heating Your Room  
You m ust select the Heat m ode if you w ish to adjust the:  
Heating tem perature  
Fan speed w hen heating  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
The air conditioner is fitted with a protection mechanism  
to prevent the unit from being damaged when it is started  
immediately after being:  
IMPORTANT  
Plugged in  
Stopped  
It will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control, press the  
button on the remote control one or more times until it appears.  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in HEAT mode.  
button.  
No t e You can change modes at any time.  
3
To adjust the temperature, press the  
buttons one or more times  
until the required temperature is displayed.  
Possible temperatures are between 61°F(16°C) and 86°F(30°C)  
inclusive.  
Result: Each time you press the  
buttons:  
- The temperature is adjusted by 1°F  
- The indoor unit beeps  
The air conditioner starts heating, provided that the room  
temperature is lower than the desired temperature  
(selected temperature +6°F); the fan will, however, operate.  
4
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
)
Automatic (rotated :  
Low  
Medium  
High  
Result:  
Each time you press the  
button, the indoor unit beeps.  
For the first three to five minutes, the fan operates very  
slowly until the air has been sufficiently warmed. Once the  
correct temperature has been reached, the fan is automatically  
set to the required speed.  
5
To control the direction of the air flow, refer to page 16 and 17.  
E-12  
Changing the Room Temperature Quickly  
The Turbo cooling/ heating function is used to cool or heat your room as  
quickly as possible.  
Exa m p le :  
You have just com e hom e and find that the room is very  
hot. You w ish to cool it dow n as quickly as possible.  
The Turbo function operates for 30 minutes with the maximum settings before  
returning automatically to the mode and temperature previously selected.  
1
2
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when the unit  
was last used.  
The indoor unit beeps.  
Press the  
Result:  
button.  
The temperature and fan settings are adjusted automatically.  
The air conditioner cools or heats the room as quickly as possible.  
After 30 minutes, the air conditioner is reset automatically to the  
previous mode, temperature and fan settings.  
But, if you press the  
button in DRY or FAN mode,  
it will change to AUTO mode automatically.  
3
4
If you wish to stop the Turbo function before the end of the 30-minute period,  
press the  
button one or more times until  
or  
disappears.  
Result:  
The air conditioner is reset automatically to the previous mode,  
temperature and fan settings.  
To control the direction of the air flow, refer to page 16 and 17.  
E-13  
Removing Excess Humidity  
If the atm osphere in your room is very hum id or dam p, you can  
rem ove excess hum idity w ithout low ering the room tem perature too  
m uch.  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism  
to prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
It will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control, press the  
button on the remote control one or more times until it appears.  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in DRY mode.  
button.  
No t e You can change modes at any time.  
3
To adjust the temperature, press the  
buttons one or more times  
until the required temperature is displayed.  
Possible temperatures are between 65°F(18°C) and 86°F(30°C)  
inclusive.  
Result: Each time you press the  
buttons:  
- The temperature is adjusted by 1°F  
- The indoor unit beeps  
The air conditioner starts removing the excess humidity;  
the quantity of air is adjusted automatically.  
4
To control the direction of the air flow, refer to page 16 and 17.  
E-14  
Airing Your Room  
If the atm osphere in your room is stale, you can air the room using the  
Fan feature.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
2
If the  
is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in FAN mode.  
The temperature is set automatically.  
button.  
No t e  
You can change modes at any time.  
3
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
Low  
Medium  
High  
Result: Each time you press the  
button, the indoor unit beeps.  
4
To control the direction of the air flow, refer to page 16 and 17.  
E-15  
Adjusting the Air Flow Direction Vertically  
Depending on the position of the indoor unit on the w all of your room ,  
you can adjust the position of the outer air flow blade on the bottom of  
the unit, thus increasing the efficiency of the air conditioner.  
1
Press the  
button one or more times as required.  
Result: The outer blade is adjusted vertically.  
RECOMMENDATION  
When...  
Adjust the blade to face...  
Cooling  
Heating  
Upwards.  
Downwards.  
2
If you want the blade to move up and down automatically when the air  
conditioner is operating, press the  
button.  
Result: The blade move up and down, around the base position set.  
3
To stop the blade moving up and down, press the  
button again.  
No t e  
If you switch the air conditioner... Then the blade is...  
Off  
Closed completely.  
Set to the initial position powered.  
On again  
E-16  
Adjusting the Air Flow Direction Horizontally  
There are tw o sets of inner air flow blades. J ust as the outer air flow  
blade can be adjusted vertically, the inner blades can be adjusted  
horizontally.  
1
Adjust each set of inner blades to the required position, by pushing or  
pulling them sideways.  
The design and shape are subject  
to change according to the model.  
E-17  
Setting the On Timer  
The On Timer enables you to sw itch on the air conditioner automatically  
after a given period of time. You can set the period of time from  
30 minutes to 24 hours.  
1
To set the operating time, press the  
button one or more times until the  
required time is displayed. Possible time is between 0.5 hour and 24 hour  
inclusive.  
2
Press the  
(Set/Cancel) button to complete the setting.  
Result: The remaining time is displayed.  
Blinking of the timer indicator stops.  
The selected mode and the temperature on the display  
disappear after 10 seconds.  
The air conditioner will switch on automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the On timer setting.  
3
To select an operating mode in advance, press the  
button until the  
desired mode is displayed at the top of the remote control.  
Result: The air conditioner will run in the selected mode when it is  
turned on.  
To Cancel the On Timer  
1
To cancel the On Timer, press the  
timer setting disappears.  
button one or more times until the  
2
Press the  
(Set/Cancel) button.  
No t e  
If you want to turn on the air conditioner before the timer reaches  
the setting time, press the (On/Off) button.  
E-18  
Setting the Off Timer  
The Off Timer enables you to switch off the air conditioner automatically  
after a given period of time. You can set the period of time from  
30 minutes to 24 hours.  
1
To set the operating time, press the  
button one or more times until  
the required time is displayed. Possible time is between 0.5 hour and 24  
hour inclusive.  
2
Press the  
(Set/Cancel) button to complete the setting.  
Result: The remaining time is displayed.  
Blinking of the timer indicator stops.  
The air conditioner will switch off automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the Off timer setting.  
Exam ple If you would like to turn the air conditioner on after 2 hours  
and to operate it for 2 hours:  
1. Press the  
button until ‘2.0 Hr’ is displayed.  
2. Press the (Set/Cancel) button.  
3. Press the  
button until ‘4.0 Hr’ is displayed.  
4. Press the (Set/Cancel) button.  
No t e  
You can see or change the setting mode and/or the temperature  
by pressing the  
timer.  
button or the  
buttons after setting the Off  
To Cancel the Off Timer  
1
To cancel the Off Timer, press the  
timer setting disappears.  
button one or more times until the  
2
Press the  
(Set/Cancel) button.  
No t e  
If you want to turn off the air conditioner before the timer reaches  
the setting time, press the (On/Off) button.  
E-19  
Setting the Sleep Timer  
The Sleep Tim er can be used w hen you are cooling or heating your  
room to sw itch the air conditioner off autom atically after a period of  
six hours.  
No t e  
If you w ish to sw itch the unit off at a specific tim e, refer to  
page 19.  
1
2
Make sure that you have selected either COOL or HEAT mode.  
Press the  
button one or more times until  
appears on the  
remote control.  
Result: The indoor unit beeps.  
The air conditioner will be controlled as indicated in the  
illustrations below.  
Cooling The desired temperature is  
increased by 2°F every hour.  
When it has been increased  
by 4°F (after two hours), the  
temperature is maintained for  
four hours.  
Heating The desired temperature is  
decreased by 2°F every hour.  
When it has been decreased  
by 4°F (after two hours), the  
temperature is maintained for  
four hours.  
To Cancel the Sleep Timer  
If you no longer w ish to use the Sleep Tim er that you have set, you  
can cancel it at any tim e.  
Press the  
Result:  
button.  
The indoor unit beeps.  
The  
The air conditioner operates normally.  
is no longer displayed.  
E-20  
Operating Recommendations  
Here are a few recom m endations that you should follow w hen using  
your air conditioner.  
Topic  
Recommendation  
Heating performances  
The heat pump inside the air conditioner  
absorbs heat from outside air and brings it  
indoors. If the temperature of the outside air  
drops, the air conditioner will heat less. If you  
find that the room is not warm enough, use an  
additional heating appliance.  
Warm air circulation  
The air conditioner circulates warm air to heat  
your room; as a result, some time will be  
required after starting the air conditioner to  
warm the entire room. If necessary, set the air  
conditioner on before you wish to use the  
room.  
Frost  
When outside temperatures are low and  
humidity is high, frost may form in the outdoor  
unit when heating is selected.  
If this happens:  
The heating operation is stopped.  
The Deice mode is triggered automatically  
for about seven minutes.  
No intervention is required from you; after  
about seven minutes, the air conditioner starts  
operating again normally.  
High indoor and outdoor If both the indoor and outdoor temperatures  
temperatures  
are high and you select the Heat mode, the  
outdoor units fan and compressor may stop at  
times. This is normal; simply wait until the air  
conditioner switches on again.  
Power failure  
If a power failure occurs when the air conditioner  
is operating, the unit is switched off.  
When the power returns,  
◆◆A1◆  
◆◆A5◆  
◆◆A9◆  
◆◆AA◆  
you must press the  
button to restart it.  
(On/Off)  
◆◆A0◆  
◆◆A2◆  
◆◆A6◆  
◆◆AB◆  
the air conditioner starts up  
again automatically  
No t e  
Be sure which model you have purchased because some  
air conditioners do not restart automatically.  
E-21  
Temperature and Humidity Ranges  
The follow ing table indicates the tem perature and hum idity ranges  
w ithin w hich the air conditioner can be used.  
If the air conditioner is used at... Then...  
High temperatures  
The automatic protection feature may  
be triggered and the air conditioner  
stopped.  
Low temperatures  
A water leak or some other malfunction  
may occur if the heat exchanger  
freezes.  
High humidity levels  
Water may condense on and drip  
from the surface of the indoor unit if it  
is used for long periods.  
Mode  
Outdoor Temperature  
Indoor Temperature Indoor Humidity  
Heating 32°F to 75°F approx.  
81°F or less  
0°C to 24°C approx.  
27°C or less  
-
Cooling  
Drying  
70°F to 109°F approx.  
65°F to 90°F approx.  
21°C to 43°C approx.  
18°C to 32°C approx. 80% or less  
65°F to 109°F approx.  
65°F to 90°F approx.  
18°C to 43°C approx.  
18°C to 32°C approx.  
-
◆◆ If the heating operation is used at below 32°F/0°C(outdoor temperature),  
it does not heat as its full capacity.  
If the cooling operation is used at over 92°F/33°C(indoor temperature),  
it does not cool as its full capacity.  
E-22  
Cleaning Your Air Conditioner  
◆◆09/12◆  
To get the best possible use out of your air conditioner, you m ust  
clean it regularly to rem ove the dust that accum ulates on the air filter.  
Before cleaning your air conditioner, ensure that you  
have sw itched off the breaker used for the unit.  
IMPORTANT  
1
2
Open the front grille by pulling on the tabs on the lower right and left  
sides of the indoor unit.  
◆◆09/12◆  
Disassemble the front grille by pulling it forwards.  
No t e  
◆◆18/24models are not included.  
3
◆◆09/12◆  
Hold the edge of the air filter under the front grille and pull to release them.  
◆◆18/24◆  
Lift out the bottom edge of the air filters and pull down to release them.  
◆◆18/24◆  
4
5
Remove all dust on the air filters with a vacuum cleaner or brush.  
Clean the front panel with a damp cloth and mild detergent  
(do NOT use benzene, solvents or other chemicals).  
6
◆◆18/24◆  
When you have finished, insert the top part of the filters into their slot and push  
down on the bottom edge until they click into place.  
No t e  
◆◆09/12models are not included.  
7
Reassemble the air filters and the front grille.  
Hook  
Front grille  
Not e  
◆◆ If you have not used the air conditioner for a long period of time, set the  
fan going for three to four hours to dry the inside of the air conditioner  
thoroughly.  
Body groove  
◆◆ Clean the air filter twice a month. It is recommendable to clean the  
air filter more often if your room has heavy dusts.  
E-23  
Solving Common Problems  
Before contacting the after-sales service, perform the follow ing sim ple checks.  
They m ay save you the tim e and expense of an unnecessary call.  
Problem  
Explanation/Solution  
The air conditioner does not  
operate at all  
Check that the breaker used for the air conditioner is switched on.  
Check that the 5 Way indicator on the indoor unit is on;  
if necessary press the  
(On/Off) button on the remote control.  
Check whether the TIMER indicator on the indoor unit is switched on.  
If so:  
- Wait until the switch-on time is reached and the air conditioner starts  
up automatically  
- Cancel the timer (see pages 18 and 19 for further details)  
The air conditioner does not  
operate with the remote control  
Check that there are no obstacles between you and the indoor unit.  
Check the remote control batteries.  
Check that you are close enough to the indoor unit  
[23ft(7m) or less].  
No beep is heard when you press  
Check that you are pointing the remote control at the remote control  
sensor in the right of the indoor unit.  
the  
(On/Off) on the remote  
control  
Replace the remote control batteries if necessary.  
The air conditioner does not cool  
or heat  
Check that the correct operating mode has been selected  
(AUTO, COOL, HEAT).  
The room temperature may be too low or too high.  
Dust may be blocking the air filter guard; refer to page 23 for cleaning  
instructions.  
Check that there is no obstacle in front of the outdoor unit.  
When heating, the required room  
temperature is never reached and  
the air conditioner frequently stops  
Check that the required temperature has been set correctly.  
Increase the fan speed.  
If the air flow is directed downwards, use the remote control to direct it  
upwards.  
The fan speed does not change  
Check that the operating mode is set to COOL, HEAT or FAN ;  
in the AUTO mode, the fan speed changes automatically and in the  
DRY mode, it is set to AUTO.  
when you press the  
button  
The air flow direction does not  
change when you press the  
button  
Check that the air conditioner has been switched on; if necessary,  
press the  
(On/Off) button on the remote control.  
The timer is not correctly triggered  
Check that the timer has been programmed correctly; see pages 18  
and 19.  
Odours are permeated in the room Air the room.  
during air conditioning  
E-24  
Installing a Filter (Option)  
The air conditioner can be fitted w ith a deodorizing and Bio-Pure  
filter to rem ove m inute dust particles or odours. The service life of  
the filter is approxim ately three m onths depending on the tim e  
during w hich the air conditioner is used.  
1
Remove the vinyl packing from the filter.  
No t e  
Do not remove the packing from a deodorizing filter until you  
wish to use the filter, as it will lose its properties.  
Deodorizing  
filter  
2
3
Insert the filter in the filter holder and press the three insert tabs until  
you hear a click.  
Bio-Pure Filter  
Open the front grille by pulling on the tabs on the lower right and left  
sides of the indoor unit.  
4
Take out the existing filter and replace it with the new one.  
E-25  
Technical Specifications  
MODEL  
AQ09A5(6)MAF  
AQ12AA(B)MCF  
Capacity Cooling  
Capacity Heating  
HSPF  
Btu/h  
Btu/h  
9000  
9500  
7.0  
11500  
Performance  
Ratings  
12500  
6.8  
SEER  
10.0  
10.0  
Moisture Removal  
Pts/h  
3
4
261  
230  
Air FLOW(Cooling, HIGH) CFM  
Air FLOW(Heating, HIGH) CFM  
247  
286  
51  
55  
Sound Rating-Outdoor  
Power source  
dB  
115V~, 60Hz  
8.1  
208-230V~, 60Hz  
5.4  
Electrical  
Data  
A
Min.Ampacity  
W
W
Cooling Watts  
950  
1230  
Heating Watts  
870  
1300  
Connections  
Flare  
41 (6.35)  
83 (9.52)  
Flare  
Refrigeration  
Lines  
41 (6.35)  
21 (12.70)  
Liquid Line O. D.  
Suction Line O.D.  
Factory Pre-charge  
Max. Line length  
Max. Height Difference  
INDOOR UNIT  
inch(mm)  
inch(mm)  
ft(m)  
3(7.5)  
( 24 4  
1 (15.0)  
( 49 4  
3(7.5)  
( 24 4  
1 (15.0)  
( 49 4  
ft(m)  
23(7.0)  
23(7.0)  
ft(m)  
Dimensions  
& Weight  
AQ09A5(6)MAF  
AQ12AA(B)MCF  
( 31 18  
921  
621  
( 31 18  
921  
621  
x
x
x
x
)
)
inch(mm)  
W X H X D  
(790 x 245 x 165)  
(790 x 245 x 165)  
Ibs(kg)  
Net Weight  
21.2(9.6)  
21.2(9.6)  
UQ09A5(6)MAF  
OUTDOOR UNIT  
UQ12AA(B)MCF  
1
19 21 94  
20 43  
x
x
x
x
26  
29  
9
inch(mm)  
W X H X D  
Net Weight  
(660 x 497 x 235)  
(740 x 530 x 230)  
Ibs(kg)  
60.7(27)  
73.2(33)  
Standard rating conditions Cooling  
Indoor  
Outdoor  
DB  
80  
WB  
67  
DB  
95  
WB  
75  
°F  
26.7  
19.4  
35.0  
23.9  
°C  
Heating  
Indoor  
Outdoor  
DB  
70  
WB  
60  
DB  
47  
WB  
43  
°F  
21.1  
15.6  
8.3  
6.1  
°C  
E-26  
MODEL  
Capacity Cooling  
Capacity Heating  
HSPF  
AQ18A9(0)RCF/AQ18A9(0)RCFD AQ24A1(2)RC/ AQ24A1(2)RCD  
Btu/h  
Btu/h  
17500  
23500  
24000  
6.8  
Performance  
Ratings  
19000  
6.8  
SEER  
10.0  
10.0  
Moisture Removal  
Pts/h  
4.5  
5.4  
457  
477  
Air FLOW(Cooling, HIGH) CFM  
Air FLOW(Heating, HIGH) CFM  
486  
512  
58  
208-230V~, 60Hz  
7.6  
59  
Sound Rating-Outdoor  
Power source  
dB  
208-230V~, 60Hz  
10.5  
Electrical  
Data  
A
Min.Ampacity  
W
W
Cooling Watts  
1700  
2350  
Heating Watts  
1730  
2400  
Flare  
Connections  
Flare  
Refrigeration  
Lines  
1
1
4 (6.35)  
Liquid Line O. D.  
Suction Line O.D.  
Factory Pre-charge  
Max. Line length  
Max. Height Difference  
INDOOR UNIT  
inch(mm)  
inch(mm)  
ft(m)  
4 (6.35)  
1
5
8 (15.88)  
2 (12.70)  
24 43 (7.5)  
49 41 (15.0 )  
16 21 (5.0)  
65 21 (20.0)  
ft(m)  
1 (8.0 )  
26 4  
ft(m)  
23(7.0)  
Dimensions  
& Weight  
AQ18A9(0)RCF/AQ18A9(0)RCFD  
AQ24A1(2)RC/AQ24A1(2)RCD  
42 12 11 x 8  
42 12 11 x 8  
x
x
inch(mm)  
W X H X D  
(1080 x 275 x 204)  
29.7(13.4)  
(1080 x 275 x 204)  
29.7(13.4)  
Ibs(kg)  
Net Weight  
UQ18A9(0)RCF/UQ18A9(0)RCFD  
OUTDOOR UNIT  
UQ24A1(2)RC/UQ24A1(2)RCD  
3
x 24 8 x 12 58  
34 85 x25 81 x12 14  
(880 x 638 x 310)  
31  
inch(mm)  
W X H X D  
Net Weight  
(787 x 620 x 320)  
101.4(45)  
138.9(62)  
Ibs(kg)  
E-27  
THIS AIR CONDITIONER IS MANUFACTURED BY:  
ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:  
CE CLIMATISEUR EST FABRIQUE PAR:  
ELECTRONICS  
Printed in Korea  

Listen Technologies La 361 User Manual
Omega Speaker Systems 23991 User Manual
Omnitek Omniprox Reader Op40 User Manual
Panasonic Kx Ps8000 User Manual
Quantum Lc 15000 User Manual
Riccar Summer Breeze Rsbh C User Manual
Sanyo Twicell Hr Aaau User Manual
Sunbeam Allergysmart 2541 User Manual
Xerox Dcc360 User Manual
York Yphbc User Manual