Panasonic Cu E28ekr User Manual

F565206  
Operating Instructions  
Air Conditioner  
CS-E24EKRS  
CS-E28EKR  
CU-E24EKR  
CU-E28EKR  
ENGLISH  
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.  
2 ~ 9  
Manufactured by:  
© 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd  
(11969-T). All rights reserved. Unauthorized copying  
and distribution is a violation of law.  
Panasonic HA Air-Conditioning (M) Sdn. Bhd.  
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site,  
40300 Shah Alam, Selangor, Malaysia.  
REGULATORY INFORMATION  
Operation Condition  
Use this air conditioner under the  
following temperature range.  
The appliance is not intended for use by young children or the infirm person without supervision. Young  
children should be supervised to ensure that they do not play with the appliance.  
Indoor  
Temperature (°C)  
Environmental Requirements  
Environmental Requirements  
*DBT *WBT  
Maximum  
Minimum  
Maximum  
Minimum  
32  
16  
30  
16  
23  
11  
COOLING  
HEATING  
Battery Disposal  
The batteries must be recycled or disposed of properly.  
Outdoor  
Temperature (°C)  
Maximum  
*DBT *WBT  
End-of-Life Disposal  
End-of-Life Disposal  
43  
16  
24  
-5  
26  
11  
18  
-6  
COOLING  
Minimum  
Maximum  
Minimum  
HEATING  
*DBT: Dry bulb temperature  
*WBT: Wet bulb temperature  
“Instructions for end-user” for air conditioners:  
Information on Disposal in other countries outside the European Union  
This symbol is only valid in the European Union. If you wish to discard this product, please contact  
your installer, dealer or local authority and ask for the correct method of disposal.  
Note:  
The illustrations in this manual  
are for explanation purposes only  
and may differ from the actual unit. It  
is subjected to change without notice  
for future improvement.  
3
PRODUCT OVERVIEW  
About  
Remote Control Preparation  
Air intake  
Indoor Unit  
Indoor Unit  
1. Pull out  
the cover.  
Supersonic air  
purifying device  
Auto OFF/ON  
button  
Front panel  
Air filter  
R
SUPE  
USTER  
-B  
U
N  
LER  
AL  
WER
PO  
2. Insert AAA or R03  
batteries.  
UIET  
Q
TIMER  
WER  
PO  
Receiver  
3. Close the cover.  
4. Press CLOCK.  
5. Press to  
set time.  
TIMER  
ON  
SET  
3
Indicator  
Airflow direction  
louver  
1
2
OFF  
CANCEL  
AC  
RC  
SET CHECK COCK  
RESET  
Ionizer  
Do not touch  
during operation  
Discharged air  
6. Press again.  
• Timer operation will be based on  
current time set.  
Outdoor Unit  
Outdoor Unit  
Air inlet (rear)  
• The batteries can be used for  
approximately 1 year.  
Remote Control Signal  
Air inlet (side)  
• Make sure it is not obstructed.  
• Maximum distances: 10m  
Air outlet  
• Certain fluorescent lights may  
interfere with signal transmission.  
Please consult your nearest dealer.  
Transmitter  
Remote Control  
Remote Control  
Auto OFF/ON Button  
Action  
Mode  
Press once.  
Automatic  
Press and hold  
until you hear  
one beep, then  
release.  
LCD display  
Off/On  
Cooling  
Heating  
Ion operation  
Operation mode  
Quiet Operation  
Press and hold  
until you hear  
one beep then  
release.  
Press and hold  
again until you  
hear two beeps  
then release.  
Temperature setting  
Fan Speed selection  
Timer setting  
Powerful Operation  
Airflow direction  
adjustment  
Check  
To turn off, press the AUTO OFF/ON  
button again.  
Clock setting  
* For normal operation, the and reset buttons are not in use.  
* Press reset button to restore the remote control’s default setting.  
Troubleshooting  
● In the event of an error, the unit will stop and the timer indicator will blink.  
Notes:  
2. Press until you hear beep  
sound, then jot down the  
error code.  
1. Press for 5 seconds.  
• The unit may be operable (with 4 beeps)  
on a limited basis, depending on the error.  
TIMER  
ON  
SET  
3
3. Press for 5 seconds to quit  
checking.  
1
2
OFF  
CANCEL  
AC  
RC  
SET CHECK CLOCK  
RESET  
4. Turn the unit off and reveal the  
error code to your nearest dealer.  
4
AUTO, HEAT, COOL, DRY  
Operation Details  
AUTO - Automatic Operation  
• Unit selects the operation mode  
according to temperature setting,  
outdoor and room temperature.  
• The power indicator blinks during  
operation.  
1
• Operation mode is reselected  
every 30 minutes.  
Start the  
operation.  
HEAT - Heating Operation  
• In heating mode, it takes a while  
for the unit to warm up. The  
power indicator blinks during this  
operation.  
2
AUTO  
HEAT  
COOL  
DRY  
FAN  
SP
Select the  
desired  
COOL - Cooling Operation  
• Enjoy cool air at your desired  
temperature.  
IR  
SWING  
operation.  
ION  
DRY - Soft Dry Operation  
• Keeps your environment  
dehumidified by running a very  
gentle cooling operation.  
OFF/ON  
MODE  
ion  
QUIET  
• During soft dry operation, the  
indoor fan operates at low fan  
speed.  
TEMP  
POWERFUL  
FAN SPEED  
AIR SWING  
TIMER  
ON  
SET  
3
Hint  
3
• A temperature setting 1°C higher  
in cooling operation or 2°C lower in  
heating operation than the desired  
temperature equates to a 10%  
power saving.  
1
2
Set the  
temperature.  
(16°C~30°C)  
OFF  
CANCEL  
AC  
RC  
SET CHECK CLOCK  
RESET  
INVERTER  
● Supersonic air purifying device (super alleru-buster) operates  
automatically once the unit is switched on.  
,
and  
operations are available in all modes.  
Press  
again to stop the operation.  
Troubleshooting  
● Mist emerges from indoor unit.  
► Condensation effect due to cooling process.  
► Ensure temperature is set correctly.  
Heating/Cooling operation does not work.  
► Make sure windows and doors are closed.  
► Make sure filters are cleaned and replaced.  
► Make sure inlet and outlet vents are cleared.  
● Water flowing sound during operations.  
► Cause by refrigerant flow inside the unit.  
● The power indicator blinks during the operation and  
the indoor fan is stopped.  
► The unit is in defrost mode, and the melted frost is drained from the  
outdoor unit.  
5
FAN SPEED, AIR SWING  
Operations Details  
• There are 5 fan speeds, as well as  
automatic*.  
* For automatic fan speed, the speed  
of the indoor fan is automatically  
adjusted according to the operation.  
AIR SWING  
Select fan  
speed.  
• Keeps the room ventilated.  
• There are 5 options for vertical/  
horizontal airflow direction.  
• Do not adjust the vertical and  
horizontal louvers by hand.  
AUTO  
HEAT  
COOL  
DRY  
FAN  
SPEED  
AIR  
SWING  
Adjust the  
airflow  
direction louver.  
ION  
• If automatic vertical airflow direction  
has been set, the louvers swing up  
and down automatically.  
OFF/ON  
MODE  
ion  
• For HEATING operation, the air  
blows horizontally for a while, then  
starts to blow downwards.  
QUIET  
TEMP  
POWERFUL  
FAN SPEED  
• If automatic horizontal airflow  
direction has been set, the louvers  
swing left and right automatically.  
AIR SWING  
TIMER  
ON  
• For HEATING operation, the airflow  
louvers start to swing left/right after  
the temperature rises.  
SET  
3
1
2
OFF  
CANCEL  
AC  
RC  
SET CHECK CLOCK  
RESET  
INVERTER  
Troubleshooting  
● The room has a peculiar odour.  
► This may be a damp smell emitted by the wall, carpet, furniture or  
clothing.  
● Indoor fan stops occasionally during automatic fan  
speed setting.  
► This helps to remove the surrounding odours.  
● Indoor fan stops occasionally during heating  
operation.  
To avoid unintended cooling effect.  
6
POWERFUL, QUIET, ION  
Operations Details  
To achieve setting temperature  
quickly.  
To provide a quiet environment.  
Enables  
quiet  
operation.  
Enables ion  
operation.  
• This setting provides fresh air effect  
by producing negative ion.  
AUTO  
HEAT  
COOL  
DRY  
FAN  
SPEED  
• Ion operation can be activated  
independently. Press  
off the operation.  
to turn  
AIR  
SWING  
ION  
OFF/ON  
TEMP  
MODE  
ion  
Hint  
QUIET  
To reduce power consumption, close  
the curtains when operating air  
conditioner to prevent the sunlight  
and heat from coming in.  
POWERFUL  
FAN SPEED  
AIR SWING  
TIMER  
ON  
SET  
3
1
2
Enables  
OFF  
CANCEL  
powerful  
operation.  
AC  
RC  
SET CHECK CLOCK  
RESET  
INVERTER  
and  
same time.  
operations could not be activated at the  
and operations could be cancelled by  
,
pressing the respective button again.  
Troubleshooting  
● Noisy during operation.  
► The unit may have been installed at an incline, or the front panel is not  
closed properly.  
● Operation is delayed a few minutes after restart.  
● Outdoor unit emits water/steam.  
► The delay is a protection to the unit’s compressor.  
► Condensation or evaporation occurs on pipes.  
● ION indicator on the indoor unit is blinking.  
► Press  
twice. If the indicator is still blinking, please consult your  
nearest dealer.  
7
TIMER  
Operation Details  
• The timer allows you to turn the air  
conditioner on or off automatically.  
• The unit may start in preliminary  
operation before the actual set time  
when ON timer has been set.  
• The set timer repeats daily once  
set.  
• If there is a power failure, you can  
restore the previous setting (once  
power is resumed) by pressing the  
button.  
AUTO  
HEAT  
COOL  
DRY  
FAN  
SPEED  
2
• If the timer is cancelled, press  
to restore the previous setting.  
Set the  
desired time.  
AIR  
SWING  
ION  
1
Select ON or  
OFF timer.  
OFF/ON  
MODE  
ion  
Hints  
QUIET  
• Press and hold the  
for  
3
approximately 5 seconds to set  
either 12-hour (am/pm) or 24-hour  
time indication.  
TEMP  
POWERFUL  
FAN EED  
Confirm the  
setting.  
To dim the indicator display:  
AIR SWN
MER  
N  
SET  
3
Press and  
hold for 5  
seconds.  
1
2
TIMER  
ON  
To cancel,  
press the  
SET  
3
OFF  
ANCEL  
1
2
AC  
RC  
again  
for 5 seconds.  
OFF  
CANCEL  
AC  
RC  
SET CHECK LOCK  
RESET  
SET HECK CLOCK  
RESET  
INVERTER  
To switch the temperature setting  
to °C or °F, press and hold  
approximately 10 seconds.  
for  
Cancel the  
selected timer.  
● The timer is valid only when the clock is set correctly.  
You can set your preferred time for ON and OFF timers.  
The unit will turn ON or OFF automatically.  
To cancel ON or OFF timer, press  
.
or  
, then press  
Troubleshooting  
● Timer indicator always on.  
● Remote control does not work.  
● The unit does not work.  
► The timer setting repeats daily once set.  
► The batteries are inserted incorrectly or need replacing.  
► The circuit breaker is tripped or the timer is set incorrectly.  
● Power indicator blinks before the unit is switched on. ► This is a preliminary step in preparation for the operation when the ON  
timer has been set.  
8
CARE & CLEANING  
Washing Instructions  
• Do not use benzene, thinner or  
scouring powder.  
Switch off the power supply  
before cleaning  
• Use only soaps or neutral household  
detergent ( pH7).  
• Do not use water hotter than 40°C.  
FRONT PANEL  
FRONT PANEL  
Raise and pull to remove.  
Wash and dry.  
INDOOR UNIT  
• Wipe the unit gently with a soft, dry  
cloth.  
AIR FILTER  
AIR FILTER  
AIR FILTER  
• Air filters cleaning is needed every  
two weeks.  
Vacuum, wash and dry.  
• Replace any damaged filters.  
Part no: CWD001137 (Left)  
CWD001138 (Right)  
SUPER ALLERU-BUSTER  
Remove  
• It is recommended to clean this filter  
every 6 months.  
• Replace the filter every 3 years or  
replace any damaged filters.  
Part no: CZ-SA13P  
Remove  
IONIZER  
• Ionizer cleaning is recommended  
every 6 months.  
INDOOR  
INDOOR  
UNIT  
UNIT  
Wipe gently.  
Hints  
• Clean the filter regularly for best  
performance and to reduce power  
consumption.  
SUPERSONIC AIR  
SUPERSONIC AIR  
PURIFYING DEVICE  
PURIFYING DEVICE  
• Please consult your nearest dealer  
for seasonal inspection.  
Vacuum the super  
alleru-buster filter.  
IONIZER  
Clean with cotton  
bud.  
IONIZER  
Remove  
Vacuum, wash and  
dry the frame.  
For extended non-use  
• Activate heating for 2~3 hours to thoroughly dry the unit.  
• Turn off the power supply.  
• Remove the remote control batteries.  
9
SEASONAL INSPECTION AFTER EXTENDED NON-USE:  
• Checking of remote control batteries.  
• No obstruction at inlet and outlet vents.  
• After 15 minutes of operation, it is normal to have the following temperature difference between inlet and outlet vents:  
Cooling: ≥ 8°C  
Heating: ≥ 14°C  
10  
NON SERVICEABLE CRITERIAS  
TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions:  
• Abnormal noise during operation.  
• Circuit breaker switches off frequently.  
• Power cord becomes unnaturally warm.  
• Switches or buttons are not functioning properly.  
• Water/foreign particles have entered the Remote Control.  
• Water leak from Indoor unit.  
11  
Printed in Malaysia  
OPTH0510-00  
Matsushita Electric Industrial Co., Ltd.  
F565206  

Mitsubishi 6a1 Series User Manual
Mitsubishi G 50a User Manual
Samsung Am27b1c07 User Manual
Samsung Uh035cav User Manual
Smart Ups Apcrbc124j User Manual
Smc Networks Robo Cylinder Ra7ad User Manual
Teledyne Automobile Parts Hfm I 401 User Manual
Tripp Lite 98 121 User Manual
Whirlpool Acps82 User Manual
Whynter Air Conditioner Arc 08wb User Manual