Panasonic Cu E18jkk User Manual

Operating Instructions  
Air Conditioner  
Model No.  
Indoor Unit  
Single Split  
Outdoor Unit  
CS-E9JKKW  
CS-E12JKKW  
CS-E18JKK  
CS-E22JKK  
CU-E9JKK  
CU-E12JKK  
CU-E18JKK  
CU-E22JKK  
Multi Split  
Outdoor Unit  
CU-2E18JBK  
ENGLISH  
2 ~ 9  
Before operating the unit, read these operating  
instructions thoroughly and keep them for future  
reference.  
FRANÇAIS  
11 ~ 19  
Avant d’utiliser le climatiseur, lire ces instructions  
d’utilisation et les conserver pour s’y référer dans  
le futur.  
QUICK GUIDE  
GUIDE SOMMMAIRE  
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2009.  
Unauthorized copying and distribution is a violation  
of law.  
F567333  
WARNING  
CAUTION  
POWER SUPPLY  
Do not use modied cord,  
INDOOR UNIT AND OUTDOOR UNIT  
Do not wash the indoor unit with water, benzene,  
thinner or scouring powder.  
joint cord, extension cord or  
unspecied cord to prevent  
overheating and re.  
Do not use for other purpose such as  
preservation of food.  
Do not share the same power outlet with other  
equipment to prevent overheating and re.  
Do not use any combustible equipment in front of  
the airow outlet to avoid re.  
Do not operate with wet hands to prevent electric  
shock.  
Do not expose yourself directly to cold air for a  
long period.  
If the supply cord is damage, it must be replaced  
by the manufacturer, its service agent or similarly  
qualied persons in order to avoid a hazard.  
Do not sit or step on the unit, you may  
fall down accidentally.  
It is strongly recommended to be installed  
with Earth Leakage Circuit Breaker (ELCB)  
or Residual Current Device (RCD) to prevent  
electric shock or re.  
Do not touch the sharp aluminium n,  
sharp parts may cause injury.  
Do not switch ON the indoor unit when waxing  
the oor. After waxing, aerate the room properly  
before operating the unit.  
This equipment must be earthed to prevent  
electrical shock or re.  
Do not install the unit in oily and smoky areas.  
In case of emergency or abnormal conditions  
(burnt smell, etc), turn off the power supply, and  
please consult authorized dealer.  
Ensure drainage pipe is connected properly.  
Otherwise, leakage may occur.  
Aerate the room regularly.  
Prevent electric shock by switching off the power  
supply when:  
- Before cleaning or servicing.  
- Extended non-use.  
- Abnormally strong lightning activity.  
After long period of use, make sure the  
installation rack is not deteriorate to prevent the  
unit from falling down.  
REMOTE CONTROL  
Do not use rechargeable (Ni-Cd) batteries.  
It may damage the remote control.  
Remove the batteries if the unit is not going to be  
used for a long period of time.  
New batteries of the same type must be inserted  
following the polarity stated to prevent  
malfunction of the remote control.  
Indoor  
Unit  
Air Inlet  
Remote  
Control  
Air Outlet  
Power  
Supply  
Outdoor  
Unit  
Air Inlet  
Air Inlet  
Air Outlet  
3
MULTI AIR CONDITIONER SYSTEM  
Multi Split Outdoor Unit  
(CU-2E18JBK)  
DEFINITION  
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.  
INDOOR UNIT  
• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the rst unit  
that turned on.  
• During operation, heating and cooling mode could not be activated at the same time for different indoor unit. The power  
indicator blinks to indicate the indoor unit is standing by for different operation mode.  
Living room  
Multi Split Outdoor Unit  
Bedroom  
POWER SUPPLY  
Time Delay Circuit  
Models Number  
Rated Volts  
Breaker  
15 Amps  
15 Amps  
20 Amps  
25 Amps  
CS-E9JKKW / CU-E9JKK  
CS-E12JKKW / CU-E12JKK  
208/230V  
Single Split System  
Multi Split System  
CS-E18JKK / CU-E18JKK  
CS-E22JKK / CU-E22JKK  
CS-E9JKKW, CS-E9JKKW / CU-2E18JBK  
CS-E9JKKW, CS-E12JKKW / CU-2E18JBK  
CS-E12JKKW, CS-E12JKKW / CU-2E18JBK  
25 Amps  
208/230V  
4
INDOOR UNIT  
Switch off the power supply before cleaning.  
Do not touch the aluminium n, sharp parts may cause injury.  
CAUTION  
CLEANING INSTRUCTIONS  
HINT  
• Do not use benzene, thinner or scouring powder.  
• Use only soap ( pH7) or neutral household detergent.  
• Do not use water hotter than 40°C.  
To ensure optimal performance of the unit, cleaning  
maintenance has to be carried out at regular intervals.  
Dirty unit may cause a malfunction and you may see  
error code “H99”. Please consult authorized dealer.  
2
4
1
7
9
3
8
5
6
1
7
INDOOR UNIT  
AUTO OFF/ON BUTTON  
• Wipe the unit gently with a soft, dry cloth.  
• Use when remote control is misplaced or a malfunction  
occurs.  
2
FRONT PANEL  
Action  
Mode  
Remove Front Panel  
Press once.  
Auto  
• Raise and pull to remove the front panel.  
• Wash gently and dry.  
Press and hold until 1 beep is heard,  
then release.  
Press and hold until 1 beep is heard,  
then release.  
Press again until 2 beeps are heard,  
then release.  
Cooling  
Heating  
Close Front Panel  
Press the button to turn off.  
• Press down both ends of the front panel to close it  
securely.  
8
SUPER ALLERU-BUSTER FILTER  
3
4
5
REMOTE CONTROL RECEIVER  
ALUMINIUM FIN  
Vacuum the super  
alleru-buster lter.  
• It is recommended to clean the lter every 6 months.  
• Replace the lter every 3 years or replace any damaged  
HORIZONTAL AIRFLOW DIRECTION LOUVER  
lter.  
Part no.: CZ-SA14P  
E9JKKW, E12JKKW  
• Manually adjustable.  
9
AIR FILTERS  
• Air lter cleaning is required every two weeks.  
• Wash/rinse the lters gently with water to avoid damage  
to the lter surface.  
E18JKK, E22JKK  
• Do not adjust by hand.  
• Dry the lters thoroughly under the shade, away from  
re or direct sunlight.  
• Replace any damaged lters.  
6
VERTICAL AIRFLOW DIRECTION LOUVER  
• Do not adjust by hand.  
5
REMOTE CONTROL  
4
TO SELECT FAN SPEED (5 OPTIONS)  
FAN SPEED  
• For AUTO, the indoor fan speed is automatically adjusted  
according to the operation mode.  
Maximum distances: 8m  
TO ADJUST VERTICAL AIRFLOW DIRECTION  
(5 OPTIONS)  
5
AIR SWING  
• Keeps the room ventilated.  
• In COOL/DRY mode, if AUTO is set, the louver swing  
up/down automatically.  
• In HEAT mode, if AUTO is set, the louver x at  
predetermined position.  
INDICATOR  
POWER  
TIMER  
(Green)  
(Orange)  
(Orange)  
(Orange)  
QUIET  
POWERFUL  
6
TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)  
(PAGE 7)  
Press the remote control’s button  
AIR SWING  
1
TO TURN ON OR OFF THE UNIT  
• Keeps the room ventilated.  
• In COOL/DRY mode, if AUTO is set, the louver swing  
left/right and up/down automatically.  
• In HEAT mode, if AUTO is set, the horizontal louver x at  
predetermined position. The vertical louver swing left/right  
after the temperature rises.  
• Please be aware of the OFF indication on the remote  
control display to prevent the unit from starting/stopping  
improperly.  
2
TO SET TEMPERATURE  
• Selection range: 16°C ~ 30°C.  
• Operating the unit within the recommended temperature  
could induce energy saving.  
Remote Control display  
HEAT mode : 20°C ~ 24°C.  
COOL mode : 26°C ~ 28°C.  
DRY mode : 1°C ~ 2°C lower than room temperature.  
3
TO SELECT OPERATION MODE  
AUTO mode - For your convenience  
• During operation mode selection the power indicator  
blinks.  
• Unit selects operation mode every 30 minutes according  
to temperature setting, outdoor and room temperature  
(For Single Split System).  
• Unit selects operation mode every 3 hours according to  
temperature setting, outdoor and room temperature (For  
Multi Split System).  
HEAT mode - To enjoy warm air  
• Unit takes a while to warm up. The power indicator blinks  
during this operation.  
1
3
4
2
5
7
8
COOL mode - To enjoy cool air  
• Use curtains to screen off sunlight and outdoor heat to  
reduce power consumption during cool mode.  
9
10  
DRY mode - To dehumidify the environment  
• Unit operates at low fan speed to give a gentle cooling  
operation.  
13  
12  
11  
6
E9JKKW, E12JKKW  
7
TO ENJOY QUIET OPERATION  
TO SET THE TIMER  
• This operation reduces airow noise.  
To turn ON or OFF the unit at a preset time.  
ON  
TO REACH TEMPERATURE  
QUICKLY  
8
1
2
SET  
• Single Split System: This operation stops automatically  
after 20 minutes.  
OFF  
• Multi Split System: Press the button again or turn OFF the  
unit to stop this operation.  
Select ON or  
OFF timer  
Set the time  
Conrm  
ON  
Press and hold for 5 seconds to dim or restore the  
9
OFF  
To cancel ON or OFF timer, press  
press CANCEL  
or  
then  
unit’s indicator brightness.  
.
Press and hold for approximately 10 seconds to  
• When ON Timer is set, the unit may start earlier (up  
to 35 minutes) before the actual set time in order to  
achieve the desired temperature on time.  
10  
show temperature setting in °C or °F  
Press and hold for approximately 5 seconds to show  
12-hour (am/pm) or 24-hour time indication.  
• Timer operation is based on the clock set in the  
remote control and repeats daily once set. For clock  
setting, please refer to Remote Control Preparation at  
back cover.  
11  
12 Press to restore the remote control’s default setting.  
13 Not used in normal operations.  
NOTES  
• If timer is cancelled manually or due to power failure,  
you can restore the previous setting (once power is  
SET  
resumed) by pressing  
.
QUIET  
POWERFUL  
,
• Can be activated in all modes and can be cancelled by  
pressing the respective button again.  
QUIET  
POWERFUL  
,
• Cannot be selected at the same time.  
6
E18JKK, E22JKK  
7
TROUBLESHOOTING  
The following symptoms do not indicate malfunction.  
SYMPTOM  
CAUSE  
Mist emerges from indoor unit.  
Water owing sound during operation.  
The room has a peculiar odour.  
• Condensation effect due to cooling process.  
• Refrigerant ow inside the unit.  
• This may be due to damp smell emitted by the wall,  
carpet, furniture or clothing.  
Indoor fan stops occasionally during automatic fan speed  
setting.  
• This helps to remove the surrounding odours.  
Airow continues even after operation has stopped.  
• Extraction of remaining heat from the indoor unit  
(maximum 30 seconds).  
Operation is delayed a few minutes after restart.  
Outdoor unit emits water/steam.  
• The delay is a protection to the unit’s compressor.  
• Condensation or evaporation occurs on pipes.  
• The timer setting repeats daily once set.  
Timer indicator is always on.  
Power indicator blinks during HEAT mode with no warm air • The unit is in defrost mode (and AIR SWING is set to  
supply (and louver is closed).  
AUTO).  
Indoor fan stops occasionally during heating operation.  
Power indicator blinks before the unit is switched on.  
To avoid unintended cooling effect.  
• This is a preliminary step in preparation for the operation  
when the ON timer has been set.  
Cracking sound during operation.  
• Changes of temperature cause the expansion/contraction  
of the unit.  
Check the following before calling for servicing.  
SYMPTOM  
CHECK  
Heating/Cooling operation is not working efciently.  
• Set the temperature correctly.  
• Close all doors and windows.  
• Clean or replace the lters.  
• Clear any obstruction at the air inlet and air outlet vents.  
Noisy during operation.  
• Check if the unit has been installed at an incline.  
• Close the front panel properly.  
Remote control does not work.  
(Display is dim or transmission signal is weak.)  
• Insert the batteries correctly.  
• Replace weak batteries.  
The unit does not work.  
• Check if the circuit breaker is tripped.  
• Check if timers have been set.  
The unit does not receive the signal from the remote  
control.  
• Make sure the receiver not obstructed.  
• Certain uorescent lights may interfere with signal  
transmitter. Please consult authorized dealer.  
The unit stops and the timer indicator blinks.  
Use remote control to retrieve error code.  
TIMER  
Press for 5  
Note:  
ON  
SET  
3
1
3
4
Press until you hear  
beep sound, then  
write down the error  
code.  
2
seconds.  
• For certain errors, you  
may restart the unit for  
limited operation with 4  
beeps during operation  
starts.  
1
2
Press for 5  
seconds to  
quit checking.  
OFF  
CANCEL  
AC  
RC  
SET CHECK CLOCK  
RESET  
Turn the unit off and reveal the error code to authorized dealer.  
8
INFORMATION  
Information for Users on Collection and Disposal of Old Equipment and used Batteries  
[Information on Disposal in other Countries  
outside the European Union]  
Note for the battery symbol (bottom two  
symbol examples):  
These symbols are only valid in the European  
Union. If you wish to discard these items,  
please contact your local authorities or dealer  
and ask for the correct method of disposal.  
This symbol might be used in combination with  
a chemical symbol. In this case it complies with  
the requirement set by the Directive for the  
chemical involved.  
Pb  
Models Number  
CS-E9JKKW / CU-E9JKK  
CS-E12JKKW / CU-E12JKK  
CS-E18JKK / CU-E18JKK  
Single Split System  
Multi Split System  
CS-E12JKKW, CS-E12JKKW / CU-2E18JBK  
The above listed models have been designed and manufactured to meet ENERGY STAR® criteria for  
energy efciency when matched with appropriate coil components. However, proper refrigerant charge  
and proper air ow are critical to achieve rated capacity and efciency. Installation of this product should  
follow the manufacturer’s refrigerant charging and airow instructions. Failure to conrm proper charge and  
airow may reduce energy efciency and shorten equipment life.  
FOR SEASONAL INSPECTION AFTER EXTENDED  
SERVICEABLE CRITERIAS  
NON-USE  
TURN OFF POWER SUPPLY then please consult  
authorized dealer under the following conditions:  
• Abnormal noise during operation.  
• Water/foreign particles have entered the remote control.  
• Water leaks from Indoor unit.  
• Circuit breaker switches off frequently.  
• Power cord becomes unnaturally warm.  
• Switches or buttons are not functioning properly.  
• Timer indicator blinks.  
• Checking of remote control batteries.  
• No obstruction at air inlet and air outlet vents.  
• After 15 minutes of operation, it is normal to have the  
following temperature difference between air inlet and air  
outlet vents:  
Cooling: 8°C  
Heating: 14°C  
FOR EXTENDED NON-USE  
• Activate Heat mode for 2~3 hours to remove moisture left  
in the internal parts thoroughly to prevent mould growth.  
• Turn off the power supply.  
• Remove the remote control batteries.  
9
QUICK GUIDE/GUIDE SOMMAIRE  
Remote Control Preparation • Préparation de la télécommande  
1
2
Pull out • Dégager le couvercle  
1
2
Insert AAA or R03 batteries (can be used ~ 1 year) •  
Mettre en place des piles AAA ou R03 (durée de vie d’environ 1 an)  
3
Close the cover • Remettre le couvercle en place  
Press CLOCK • Appuyer sur CLOCK  
Set time • Régler l’heure  
3
4
5
6
4
TIMER  
ON  
5
6
SET  
1
2
3
OFF  
CANCEL  
AC  
RC  
Conrm • Conrmer le réglage  
SET CHECK CLOCK  
RESET  
1
MODE  
AUTO HEAT  
AUTO  
HEAT  
COOL  
DRY  
FAN  
AUTO  
HEAT  
COOL  
DRY  
FAN  
DRY  
COOL  
SPEED  
SPEED  
AIR  
SWING  
AIR  
Select the desired mode.  
Sélectionner le mode voulu.  
SWING  
OFF/ON  
TEMP  
2
OFF/ON  
TEMP  
1
3
MODE  
MODE  
FAN SPEED  
AIR SWING  
FAN SPEED  
AIR SWING  
2
OFF/ON  
Start/stop the operation.  
QUIET POWERFUL  
QUIET POWERFUL  
Mettre l’appareil en/hors marche.  
TIMER  
ON  
TIMER  
ON  
SET  
3
SET  
3
1
2
1
2
OFF  
CANCEL  
OFF  
CANCEL  
AC  
RC  
AC  
RC  
3
TEMP  
SET CHECK CLOCK  
RESET  
SET CHECK CLOCK  
RESET  
Select the desired temperature.  
Régler la température souhaitée.  
E9JKKW, E12JKKW  
E18JKK, E22JKK  
Panasonic Corporation  
Panasonic Canada Inc.  
Imprimé en Malaisie  
OSTH0907-00  
F567333  

Milwaukee 48 11 1815 User Manual
Ricoh 43 3808a User Manual
Sanyo C2432a User Manual
Sanyo Kr 900aaec User Manual
Sanyo W 3way Eco I Chdzr14053 User Manual
Smart Ups Apcrbc132 User Manual
Therma Stor Products Group Focus 135h User Manual
Trion Air Boss Dc 72 User Manual
Univex Professional Wireless 4 In 1 X7675 User Manual
Zebra Technologies 11280100000 User Manual