Monarch Act 1b 10 User Manual

MONARCH INSTRUMENT  
Instruction Manual  
ACT-1B, ACT-1B-10, ACT-1B-60  
Panel Tachometers  
15 Columbia Drive  
Amherst, NH 03031-2334 USA  
Phone: (603) 883-3390  
Fax: (603) 886-3300  
Printed in the U.S.A.  
© Monarch Instrument 2001 all rights reserved  
1071-4842-114  
TABLE OF CONTENTS  
DECLARATION OF CONFORMITY  
Specifications ................................................................. 1  
Overview ........................................................................ 2  
Installation and Power .................................................... 2  
Sensor Connections ...................................................... 4  
Output Options ............................................................... 6  
Options ........................................................................... 9  
Accessories / Sensors ....................................................10  
As Manufacturer:  
Monarch Instrument  
Division of Monarch International Inc.  
15 Columbia Drive, Amherst NH 03031 USA  
declares under Monarch’s sole responsibility that the product:  
Name:  
ACT - Panel Tachometer  
Models: ACT-1B, ACT-1B-10, ACT-1B-60  
to which this declaration relates is in conformity with the following standards:  
EMC:  
EN50082-1:1997  
EN50082-2:1995  
EN55011:1991 Group 1 Class B  
and therefore conforms with the requirements of Council Directive 89/336/EEC relating  
to electromagnetic compatibility. The testing of this product was performed by Retlif  
Testing Laboratories, NH, in October of 1999 (File R-351 4N2).  
8th October 1999  
Manufacturer (Amherst,NH)  
Alan Woolfson, VP Engineering (Authorized Signature)  
SPECIFICATIONS  
ACCESSORIES / SENSORS  
Range:  
Accuracy:  
Resolution:  
Display:  
Display Update:  
Dimensions:  
Power Supply:  
5 to 99,999 RPM  
±1 RPM or 0.005% of reading  
1 RPM  
5 digit, 0.56” (14 mm) high red LED  
Twice per second above 120 RPM  
1/8 DIN by 4.5” (114 mm) deep  
Standard: 115 Vac or 230 Vac ±10%, 50/60 Hz  
(Specified when ordering)  
Optional: 12 Vdc to 15 Vdc, 1.75 Watts  
Universal input for optical, proximity, two wire or  
three wire magnetic, infrared or laser Sensors  
TTL input or 1.5 Vac to 50 Vac input  
Standard inputs are 1, 10 or 60 pulses per revolution  
depending on the model. Contact factory to order  
customized pulses per revolution.  
8 Vdc at 5 mA for proximity sensors  
5 Vdc at 75 mA for all other sensors  
ROS-5W:  
T-5:  
Remote Optical Sensor  
Reflective Tape - 5 foot (1.5 m) roll, 0.5 inch (10 mm) wide  
Proximity Sensor  
P5-11:  
M-190W:  
Magnetic Sensor  
MT-190W: Magnetic Sensor with Amplifier Module  
IRS-5W:  
RLS-5W:  
Infrared Sensor  
Laser Sensor  
Inputs:  
NOTE: Standard cable length is 8 feet (2.5 m) on all sensors. Longer  
cable lengths of 15, 30, 50 or 100 feet ( 4.6, 9.2, 15 or 30.5 m)  
are optional.  
Sensor Excitation:  
Recommended Sensors: Optical  
-
Monarch ROS-5W  
Proximity - Monarch P5-11  
Magnetic  
Infrared  
Laser  
-
-
-
Monarch M-190W or MT-190W  
Monarch IRS-5W  
Monarch RLS-5W  
IO Option: 4 to 20 mA, see page 7 for maximum load calculation  
Full scale RPM settings as specified when ordered  
12 bit resolution, 4096 steps over the range specified  
AO Option: 0 to 5 Vdc, 5 mA maximum load  
Full scale RPM settings as specified when ordered  
12 bit resolution, 4096 steps over the range specified  
PO Option: 0 to 5 V TTL pulse, non-inverting, one pulse out for each  
pulse in  
1
10  
OPTIONS  
IO:  
OVERVIEW  
4 to 20 mA current output  
0 to 5 Vdc analog output  
ACT-1B Digital Tachometers display rotational speed directly in RPM on a  
5 digit red LED display using a speed sensor providing a single pulse per  
revolution (Model ACT-1B), 10 pulses per revolution (Model ACT-1B-10)  
or 60 pulses per revolution (Model ACT-1B-60). Power may be either 115  
Vac or 230 Vac (50/60 Hz), or optionally, 12 Vdc to 15 Vdc. The ACT-1B  
Series accepts input signals from optical, proximity, magnetic, infrared or  
laser sensors, or direct TTL or external ac inputs. All models are suitable for  
panel mounting or bench top, with convenient screw terminal connections  
on the rear panel of the instrument.  
AO:  
NOTE: Full scale RPM must be specified for the above  
options when ordering.  
PO:  
0 to 5 V TTL compatible pulse output  
NOTE: Pulses out per revolution equal pulses in  
per revolution.  
CAL-N.I.S.T.  
N.I.S.T. Traceable Certificate of Calibration  
If specified at time of order placement, the ACT-1B may be equipped with  
either an optional 4 to 20 mA current output (IO) or 0 to 5 Vdc analog  
output (AO) proportional to speed, and/or a TTL pulse repeater output (PO).  
INSTALLATION and POWER  
The ACT-1B enclosure is a standard 1/8 DIN size requiring a 3.58” wide by  
1.74” high (91x44 mm) mounting hole.  
ACT Front View  
ACT Side View  
Figure 1 Dimensions in Inches (mm)  
9
2
Installation  
Analog Output Option (AO)  
Remove the mounting clips, if fitted, and install the unit into the panel from  
the front. From the rear of the unit, install the mounting clips on each side  
and tighten the mounting screws against the rear of the panel.  
The analog output is 0 to 5 Vdc.  
Connect the Positive side of the signal to the terminal marked OUT,  
and the Return side of the signal to the terminal marked COM.  
WARNING: Do not over tighten the mounting screws.  
NOTE: If your ACT-1B is equipped with either a current output or  
an analog output, the full-scale output has been factory preset  
to the speed range specified at the time of purchase. The output  
is linear in 4096 discrete steps over its designated range.  
Power  
Power to the unit is connected to the terminals under the section labeled  
POWER on the rear panel. Be sure the power supplied matches the  
specification indicated on the rear panel. Refer to Figure 2 below.  
Pulse Repeater Output Option (PO)  
The Pulse Repeater output provides a conditioned TTL positive going  
5 V pulse out for each pulse in.  
Connect the Positive signal wire (+5 V pulse) to terminal marked +P  
and the Return to the terminal marked COM in the rear panel section  
labeled OUT.  
Figure 2 ACT-1B Rear Panel  
If the unit is ac powered (115 Vac or 230 Vac), connect the Live (Hot) wire  
to the terminal marked L+ and the Neutral (Return) wire to the terminal  
marked N-. Connect the Ground (Earth) wire to the terminal marked GND.  
NOTE: For full compliance with CE specifications, the Ground (GND)  
connection must be made.  
3
8
If the unit is dc powered, connect the dc supply Positive to the terminal  
marked L+ and the dc supply Negative or Common to the terminal  
marked N-.  
NOTE: On dc powered units, no connection is required to the terminal  
marked GND.  
SENSOR CONNECTIONS  
A speed sensor (not included) is connected to the terminals under the  
section labeled INPUT on the rear panel. Refer to Figure 2 and 3.  
Connections and their functions are as follows:  
+5V Positive +5 Vdc to provide power to optical, laser, infrared or  
amplified magnetic sensors. Maximum load is 75 mA dc.  
Figure 4 Current Output Option Connections  
PX+ Positive +8 Vdc supply for use with two wire proximity  
sensors. Maximum load for proper operation with two wire  
sensors is 5 mA.  
NOTE: The voltage source you use will determine the maximum  
resistance of the load. This voltage is referred to as the  
compliance voltage and must be equal to the maximum  
current through the load (20 mA) multiplied by the load  
resistance, plus 4 Vdc. For example, if the load is 1000 ohms,  
the external voltage source must be:  
SIG Positive input signal from the speed sensor. Accepts TTL pulses  
or ac signals, unipolar and bipolar, from 1.5 Vac to 50 Vac.  
(Contact the factory for increased sensitivity.) Connect the  
signal wire from three wire sensors or the positive side of two  
wire magnetic sensors to this terminal. Typical input  
impedance is 10 Kohms.  
(1000 ohms x 0.020 A) + 4 Vdc = 24 Vdc  
Thus, for an external source voltage of 24 Vdc, the  
maximum loop load (the sum of all resistances in the loop) is  
1000 ohms. 24 Vdc is, in fact, a recommended voltage. The  
voltage supplied by an external source should NEVER  
exceed 40 Vdc. The ACT-1B 15 Vdc internal voltage source  
(+VA) permits a maximum load resistance of 500 ohms.  
COM Common or Negative connection for both signal and power  
from most sensors.  
7
4
Refer to Figure 3 for connection of Monarch standard sensors. The  
connections are typical for these types of sensors.  
OUTPUT OPTIONS  
The ACT-1B may be equipped with either a Current Output (IO) or an Analog  
Output (AO), and/or a TTL Pulse Output (PO).  
NOTE: Full scale RPM settings must have been specified when ordered;  
these options are not field programmable.  
The Current or Analog Outputs are connected to the terminals in the section  
labeled ANALOG OUTPUT OPTION on the rear panel. The Pulse Output  
is connected to the terminals under the section labeled OUT on the rear  
panel.  
Shield to COM  
Shield to COM  
CAUTION: The IO or AO COM is NOT isolated from the other  
COM connections.  
Current Output Option (IO)  
The current output is 4 to 20 mA. This output is a current sink and  
requires a source voltage. A 15 Vdc internal source is provided at the  
terminal marked +VA. When using an external voltage source, the  
current from that source is regulated by the ACT-1B.  
Figure 3 Sensor Connections  
Typical connections are as follows: (See Figure 4.)  
When using the ACT-1B internal +15 Vdc source, connect the  
Positive side of the load to the terminal marked +VA and the other  
side of the load to the terminal marked OUT.  
When using an external voltage source, connect the Negative side  
of the external source to the terminal marked COM, the Positive  
side of the supply to the Positive side of the load, and the other  
side of the load to the terminal marked OUT.  
5
6

Panasonic Kx Fpg176 User Manual
Philips Ss191p User Manual
Quantum Lcs 4500 User Manual
Samsung As07sbge User Manual
Sanyo Eco G Sgp Ez150m2g2 User Manual
Sanyo Uf653450r User Manual
Sharp Af S100ex User Manual
Sharp Ar Pf1 User Manual
Toshiba Air Conditioner Rav Sm1104ut E User Manual
Toshiba Lf400 User Manual