Mitsubishi Electronics MrSlim Pkh Fak User Manual

SPLIT-TYPE AIR CONDITIONERS  
Natural Comfort  
For  
Everybody  
POWER CEILING CASSETTE  
WALL MOUNTED  
CEILING SUSPENDED  
CEILING CONCEALED  
R22  
Remote controller  
Contents  
4hp  
5hp  
6hp  
PLH-4AAK  
PLH-5AAK  
PLH-6AAK  
P.7  
PKH-4FAK  
PCH-4GAK  
PEH-4EAK  
P.8  
P.9  
PCH-5GAK  
PCH-6GAK  
Optional  
PEH-5EAK  
PEH-6EAK  
P.10  
PUH-4YKSA  
PUH-5YKSA  
PUH-6YKSA  
2
The MEQ Difference  
High performance, low power consumption,  
and excellent reliability.  
In today’s competitive environment, simply meeting industry standards, however  
stringent, is not enough. Our aim is to exceed them. That’s why when it comes to  
comfort, efficiency and durability: Mitsubishi Electric offers you a distinctive advantage.  
We call it MEQ — Mitsubishi Electric Quality. And it's a new benchmark that results  
in leading edge products, such as air conditioners that consume minimal power and  
protect your investment with a long operational lifespan. You can also enjoy superb  
reliability, as they’re built to endure the punishment of extreme weather conditions  
year in and year out.  
Mitsubishi Electric Offers  
Three Important Advantages  
Comfort  
Efficiency  
Durability  
True Comfort is Yours to  
Enjoy with Our Line-up  
Optimum Cost Performance  
and Energy Savings  
Rugged Construction, Rigorous  
Testing, Long-lasting Operation  
We create products designed to  
ensure that you and your surrounding  
will always be in a perfect harmony.  
Whichever model from our Mr. SLIM  
line-up you may choose for commer-  
cial use in restaurants, stores, or  
offices will be your guarantee of  
exceptional comfort in every and all  
operating condition.  
MEQ results in air conditioners that  
are rated among the best in the  
industry in terms of quality and energy  
efficiency. We strive for a perfect bal-  
ance of performance, reliability, low  
power consumption and long opera-  
tional life span. This is complement-  
ed by continuous introduction of new  
technologies and components that  
further reduce energy requirements  
and improve eco-friendliness.  
MEQ is behind a mindset that goes to  
extremes to ensure higher quality  
products that protect the initial  
investment over years of reliable ser-  
vice. We subject our indoor and  
outdoor units to rigorous durability  
testing, including harsher tempera-  
ture extremes than likely found  
anywhere in the world.  
3
The First Choice  
for Any and All Applications  
Whatever your requirements may be, Mitsubishi Electric offers advanced  
split-type heat pumps perfect for any interior, any need. Significantly  
decreased noise levels enhance comfort while a long list of convenient  
features allow for easy installation and far less maintenance. A variety of  
system control configurations plus twin multi operation — where multiple  
indoor units can be connected to a single outdoor unit — make  
our units the first choice for the diverse applications of today.  
New Remote Controller  
Renovating air conditioning communication  
by advanced MA Remote Controller newly developed  
Dot Liquid Crystal Display  
Multi-language Display  
Acknowledging the operation and control status at a glance.  
The large size display upgrades visual acknowledgement  
capability. The operation and control status can be understood  
promptly.  
8 languages  
can be displayed.  
Display can be switched over for 8 kinds of  
language.  
Multi-  
Ianguage  
[English]  
[French]  
[Spanish]  
[Italian]  
[German]  
Display example [Operation mode]  
Dot liquid crystal display section  
[Russian]  
[Chinese]  
[Japanese]  
Operation Control Function  
Weekly Timer  
The function of the weekly timer equipped can change the set  
temperature in addition to the ON/OFF control. Up to 8 pat-  
terns can be set for each calendar day.  
Air conditioning operation  
always within a limited  
temperature range  
Limiting the set  
temperature range  
Automatic turning off of  
Auto Off timer  
air conditioning operation  
Preventing the random  
Operation locking  
modification of setting  
4
Mr. SLIM New A/K Control System Configuration  
Control function  
System configuration  
Features  
Necessary parts & equipment  
Sequential start adaptable  
Same mode operation  
Maximum no. of units connectable per  
group: 16-refrigerant (Outdoor 16 sets)  
Interface  
Interface  
Indoor Unit  
Group control  
with 1 remote  
controller  
Remote  
MAC-397IF-E  
(one for each outdoor unit)  
Controller  
1.  
Outdoor Unit  
Relay  
Simultaneous ON/OFF remote  
Timer adapter PAC-SE55RA-E  
Combined  
Remote/local  
control  
Box  
Adapter  
Operation can be switched between  
the distant controller panel and  
handheld controller  
Distant  
Controller  
Panel  
(connect to CN32 on indoor circuit board)  
Relay box (on-site)  
2.  
3.  
4.  
Remote  
Controller  
Indoor Unit  
2 remote controllers can be connected  
to one group  
Operation with  
2 remote  
controllers  
Remote  
Controller  
Additional remote controller (option)  
Indoor Unit  
Control with the latest command  
Individual  
control from  
distant room  
Extension of remote controller cord  
(MAX. 500m)  
Remote controller cord (on-site)  
Remote  
Controller  
Indoor Unit  
Weekly timer operation possible as  
standard (7 days-8 patterns)  
5. Timer  
operation  
Optional adapter allows operation with Timer adapter PAC-SE55RA-E  
timer sold on the market  
(connect to CN32 on indoor circuit board)  
Timer adapter PAC-SE55RA-E  
(connect to CN32 on indoor circuit board)  
Static signal receivable  
Operation by  
external signal  
6.  
Multiple remote controller adpter  
PAC-725AD  
Pulse signal receivable  
(connect to CN51 on indoor circuit board)  
Power  
Supply  
Power failure  
7. automatic  
recovery  
Returns to the state before power  
failure as standard  
Indoor Unit  
Function setting by remote controller  
Remote  
Controller  
Multiple remote controller adpter  
PAC-725AD  
(connect to CN51 on indoor circuit board)  
Adapter  
Indoor Unit  
Relay  
Box  
Connection of  
remote display  
Connectable to display panel in the  
field adapter  
8.  
Distant  
Display  
Remote  
Controller  
Relay OMRON made LY-1 (DC12V)  
PAC-SE55RA-E  
Timer Adapter  
MAC-397IF-E  
MA & Control Terminal Interface  
PAC-725AD  
Multiple Remote Controller Adapter  
(10 units of PAC-SA88HA-E)  
5
Twin Multi Operation  
Two indoor units can be connected to a single outdoor unit  
and all units can be operated simultaneously from a single  
remote controller using the optional multi-distribution pipe  
(only indoor units of the same capacity and type can be  
connected).  
INDOOR UNIT  
INDOOR UNIT  
Outdoor Unit and Twin-Multi Combinations  
2.5HP  
3HP  
PKH-3FAK  
PCH-3GAK  
PLH-3AAK  
PEH-3EAK  
Applicable indoor units  
PEH-2.5EAK  
Multi-Distribution Pipe  
Twin-multi  
50:50  
Outdoor unit  
PUH-5YKSA  
PUH-6YKSA  
2.5 + 2.5  
3 + 3  
Multi-distribution pipe  
SDD-50S-E  
Note  
The capacity of both indoor units must be identical.  
Different types of indoor units with identical capacities can be  
connected.  
The height difference between both indoor units must be 1meter or  
less.  
OUTDOOR UNIT  
When two units are connected, the main unit can be used to control  
the operation of all units.  
Mr. SLIM Convenient Remote Controller  
Advanced MA remote controller  
Stylish wireless remote controller with all the latest programming features  
Wired remote controller*  
Wireless remote controller for PLH-AAK  
FAN SPEED SELECT button  
Used to change fan speed.  
Fan speed indicator  
Displays the fan speed setting  
(HIGH or LOW).  
VANE CONTROL button  
Used to change airflow direction.  
HOUR and MINUTE  
buttons  
Used to set the time and timer settings.  
MODE SELECTION button  
Used to select operating modes —  
Cool, Dry, and Heat, and Auto.  
TIMER button/  
RESET button  
TIMER CONTROL buttons  
STOP (OFF timer): When this function is  
activated, the air conditioner will auto-  
matically stop at the preset time.  
DOT LIQUID CRYSTAL display  
MULTI-LANGUAGE display  
OPERATION CONTROL function  
WEEKLY TIMER  
START (ON timer): When this function is  
activated, the air conditioner will auto-  
matically start at the preset time.  
*Please refer to page 4.  
6
P O W E R C E I L I N G C A S S E T T E  
Design uniformity improves installation flexibility  
From the smallest 3HP unit to the largest 6HP model, the new high-  
power ceiling cassettes offer a uniformly square 950 x 950mm width  
and depth design. Thanks to the uniformity of the panel size, planning  
for unit positioning in any room is enhanced and the installation of dif-  
ferent capacity models within the same floor space is made possible.  
PLH-AAK  
S E R I E S  
PLH-3AAK  
PLH-4AAK  
PLH-5AAK  
PLH-6AAK  
Unit height of only 258mm [PLH-3]  
The new high-power ceiling cassette models  
boast slim body height for smooth  
and aesthetic installation  
PLH-3AAK  
even in limited  
ceiling plenum  
applications.  
258mm  
(40mm less than  
conventional models)  
PLH-4/5/6AAK  
298mm  
Automatic vane shutter  
When the air conditioner is not operat-  
ing, the vane shutter* closes automati-  
cally to conceal the air outlet and  
create an aesthetically appealing flat  
surface.  
Vane shutter closes automatically  
During operation  
When turned off  
* This feature will not activate when the vane is set at  
fixed position.  
Wide-flow air outlet  
The new high-power ceiling  
4-way high ceiling 2  
cassettes offer a wide-flow air  
outlet that enables effective air con-  
ditioning of atrium-type ceilings up  
4.2m  
to 4.2 meters in height.  
3-way standard  
INDEX  
Ideal for high-  
The demands of high-  
ceiling applications such  
as halls, showrooms or  
shopping malls can now  
ceiling applications  
as high as  
3.6m  
Specifications .........................................p.11  
Option ......................................................p.13  
4.2m  
(PLH-4/5/6)  
4-way standard  
be fully answered thanks to this powerful yet highly  
efficient airflow.  
3.2m  
Specifications according to ceiling height and number of vents  
PLH-3  
PLH-4/5/6  
High ceiling 1 High ceiling 2  
Standard  
2.7  
High ceiling 1 High ceiling 2  
Standard  
3.2  
4-way  
3-way  
2-way  
3.0  
3.3  
3.5  
3.5  
3.5  
3.6  
4.0  
4.2  
4.2  
4.2  
3.0  
3.6  
3.3  
4.0  
* Optional air outlet shutter plate (PAC-SG06SP-E) is necessary for two- or three-way airflow settings.  
Features at-a-glance  
Installation & Maintenance  
Chargeless system  
Compact design  
Comfort  
Others  
Auto-angle airflow  
Versatile airflow  
72 airflow patterns  
Smudge/draft free  
High ceiling application  
Computerized dehumidifier  
Quiet operation  
System control  
Twin-multi operation  
Auto vane shutter  
Auto restart  
Fresh air intake  
Outdoor unit operating  
range up to 46ºC  
Drain water lift-up (850mm)  
Handy corner-pocket  
Long-life filter (2500 hrs.)  
Self-diagnostic function  
Filter indicator  
(For wired remote controller)  
Bacteria- and mold-resistant fiter  
Flockless vanes  
7
W A L L M O U N T E D  
Auto-flap shutter  
When the unit is turned off, the  
shutter closes automatically over  
the air outlet to enhance the stylish  
design. The shutter also functions  
as a flap to adjust airflow angle to  
ensure that comforting air reaches every corner of the room.  
PKH-FAK  
S E R I E S  
PKH-3FAK PKH-4FAK  
Enhanced noise suppression  
Low-noise operation has been  
Model  
PKH-3  
PKH-4  
Sound pressure level (Lo/Hi)  
achieved through the introduction  
of a “near-silent” fan and a  
design which minimises airflow  
resistance.  
39/45  
41/46  
(dB)  
Multi-directional piping  
To reduce installation time, drain piping can be connected from left  
and right. Refrigerant piping can also be connected from the rear, left,  
right and base of the unit.  
Easy removable filter  
Convenient thumbscrews on the filters  
enable the filters to be quickly removed for  
easier cleaning.  
Back plate installation guide  
To save time and effort, the back plate installation guide provides clear  
instructions on installation positions. The enlarged back plate secures  
the unit firmly to the wall, while the support piece which lifts the unit  
makes the left-side piping work much easier.  
INDEX  
Drain lift-up mechanism (optional)  
For greater installation flexibility, the drain water pipe lift-up mecha-  
nism has been raised 800mm from the base of the unit.  
Specifications .........................................p.11  
Option ......................................................p.13  
Features at-a-glance  
Installation & Maintenance  
Comfort  
Others  
Chargeless system  
Easy removable filter  
Drain water lift-up (800mm)*  
4-way multi directional piping  
Self-diagnostic function  
Auto-angle airflow  
Computerized dehumidifier  
Quiet operation  
System control  
Twin-multi operation  
Auto-flap shutter  
Outdoor unit operating  
range up to 46ºC  
*Optional  
8
C E I L I N G S U S P E N D E D  
Extra slim, extra stylish  
Sleek and slim with stylishly curved lines, the PCH-GAK Series blends  
right into any interior. It also features a single air outlet with an auto  
vane that closes like a shutter when the unit is turned off to enhance  
overall appearance.  
PCH-GAK  
S E R I E S  
Innovative auto vane system  
PCH-3GAK PCH-4GAK  
PCH-5GAK PCH-6GAK  
The auto vane system swings up and down  
automatically to distribute air more evenly  
throughout the room.  
Auto vane  
Swing  
Quiet and comfortable  
Smoother airflow, an improved air vent design, and a slimmer fan  
combine to provide exceptionally quiet operation — a mere 43dB on  
high and 37dB on low (PCH-3GAK).  
New direct suspension system  
For easier installation, the PCH-GAK Series features a new direct sus-  
pension system that makes it unnecessary to remove nuts and bolts  
from the main body. A one-touch suspension system is also available.  
Direct suspension with attachment fixture attached  
1. Leave attachment fixture attached to main unit.  
2. Suspend the attachment fixture from the suspension bolts.  
3. Simply tighten the nuts to secure the unit.  
Suspension bolts  
Ceiling surface  
Attachment fixture  
Air outlet  
INDEX  
Specifications .........................................p.12  
Option ......................................................p.13  
Piping flexibility simplifies installation  
All piping, including those related to drainage, can be connected from  
the right, rear and top of the unit. This provides greater flexibility in  
selecting piping layout and installation locations.  
Flockless vanes  
With the adoption of new flockless vanes, dirt and other impurities can  
be cleaned off easily with mild household detergent.  
Fan phase control plus microprocessor control allow  
airflow settings to match ceiling height.  
Drain water lift-up mechanism can be pre-installed  
(optional).  
Features at-a-glance  
Installation & Maintenance  
Comfort  
Others  
Chargeless system  
New direct suspension  
system  
Drain water lift-up (500mm)*  
Flexible piping  
Long-life filter (2500 hrs.)  
Washable filter*  
Auto swing  
System control  
Twin-multi operation  
Auto restart  
Auto vane shutter  
Outdoor unit operating  
range up to 46ºC  
High ceiling application  
Computerized dehumidifier  
Quiet operation  
Self-diagnostic function  
*Optional  
9
C E I L I N G C O N C E A L E D  
Limitless installation possibilities  
Offering all the benefits of split-type models plus other important  
advantages, the PEH-EAK Series is not only easy to install but also very  
versatile. For example, the distance between the air-intake and air-out-  
let vents can be varied to allow airflow to be positioned in the opti-  
mum location.  
PEH-EAK  
S E R I E S  
PEH-2.5EAK PEH-3EAK  
PEH-4EAK  
PEH-5EAK  
PEH-6EAK  
Long-rectangular room  
L-shaped room  
PEH-2.5EAK  
PEH-3EAK  
PEH-4EAK  
Room with  
fixed ceiling  
fixtures  
PEH-5EAK  
PEH-6EAK  
Computerized dehumidification  
The computerized dehumidifier mode — where fan speed is controlled  
precisely — increases dehumidification volume while improving dehu-  
midifying efficiency.  
INDEX  
Specifications .........................................p.12  
Option ......................................................p.13  
Features at-a-glance  
Installation & Maintenance  
Comfort  
Others  
Chargeless system  
Smooth instllation  
Self-diagnostic function  
Computerized dehumidifier  
Quiet operation  
System control  
Twin-multi operation  
Auto restart  
Outdoor unit operating  
range up to 46ºC  
10  
S P E C I F I C A T I O N S  
PLH-AAK  
POWER CEILING CASSETTE  
Models  
Function  
Capacity  
Total input  
COP  
PLH-3AAK  
PLH-4AAK  
PLH-5AAK  
PLH-5AAK  
PLH-6AAK  
PLH-6AAK  
Cooling  
7,700  
3.32  
Heating  
8,400  
3.11  
Cooling  
9,700  
3.46  
Heating  
10,400  
3.45  
Cooling  
12,400  
4.51  
Heating  
14,000  
4.46  
Cooling  
14,000  
5.07  
Heating  
16,100  
4.92  
W
kW  
W/W  
2.32  
2.70  
2.80  
3.01  
2.75  
3.14  
2.76  
3.27  
Model name  
PLH-3AAK  
PLH-4AAK  
External finish  
Power supply  
Galvanized sheets with gray heat insulation  
Single phase, 50Hz, 240V  
Airflow (Lo-Hi)  
l/s  
Pa ( mmAq)  
dB  
250 – 333  
28 – 34  
333 – 467  
367 – 500  
External static pressure  
Indoor unit  
0 (direct blow)  
Sound pressure level (Lo-Hi)  
Dimensions  
33 – 41  
35 – 43  
37 – 45  
W mm  
D mm  
H mm  
840  
840  
258  
24  
298  
30  
Weight  
kg  
30  
32  
External finish  
Munsell 0.70Y 8.59/0.97  
W mm  
D mm  
H mm  
kg  
950  
950  
30  
Indoor grille  
Dimensions  
Weight  
5
Model name  
PUH-3YKA  
PUH-4YKSA  
PUH-5YKSA  
PUH-6YKSA  
External finish  
Munsell 5Y 7/1  
Power supply  
3-phase 50Hz, 415V (4 wires)  
Capillary tube  
Refrigerant (R-22) control  
Compressor output  
kW  
2.4  
2.7  
3.5  
4.0  
Internal thermostat, HP switch /  
thermal relay, thermal switch,  
anti- phase protector  
Thermal relay, thermal switch, HP switch, anti-phase protector  
Protection devices  
Outdoor unit  
Airflow  
l/s  
W
833  
1,584  
38  
1,667  
Crankcase heater  
Sound pressure level  
Sound power level  
dB  
52  
66  
54  
69  
55  
56  
71  
dB  
70  
W mm  
D mm  
H mm  
kg  
870  
970  
Dimensions  
Weight  
295 + 24  
345 + 24  
1,258  
114  
850  
75  
94  
117  
PKH-FAK  
WALL MOUNTED  
Models  
Function  
Capacity  
Total input  
COP  
PKH-3FAK  
PKH-4FAK  
Cooling  
Heating  
9,100  
3.04  
Cooling  
9,500  
3.31  
Heating  
10,700  
3.30  
W
kW  
7,900  
3.25  
2.43  
W/W  
3.00  
2.87  
3.24  
Model name  
PKH-3FAK  
PKH-4FAK  
External finish  
Power supply  
Munsell 3.4Y 7.7/0.8  
Single phase, 50Hz, 240V  
Airflow (Lo-Hi)  
l/s  
Pa (mmAq)  
dB  
250 – 333  
367 – 467  
External static pressure  
Indoor unit  
0 (direct blow)  
41 – 46  
1,680  
235  
Sound pressure level (Lo-Hi)  
Dimensions  
39 – 45  
1,400  
W mm  
D mm  
H mm  
kg  
340  
Weight  
24  
28  
Model name  
PUH-3YKA  
PUH-4YKSA  
External finish  
Power supply  
Munsell 5Y 7/1  
3-ph., 50Hz, 415V (4 wires)  
Refrigerant (R-22) control  
Compressor output  
Capillary tube  
kW  
2.4  
2.7  
Internal thermostat, HP switch/thermal relay, thermal switch, HP switch,  
anti-phase protector  
Thermal relay, thermal switch, HP switch, anti-phase protector  
1,584  
Protection devices  
Outdoor unit  
Airflow  
l/s  
W
833  
Crankcase heater  
Sound pressure level  
Sound power level  
38  
dB  
52  
66  
54  
69  
dB  
W mm  
D mm  
H mm  
kg  
870  
Dimensions  
Weight  
295 + 24  
850  
75  
1,258  
94  
11  
S P E C I F I C A T I O N S  
PCH-GAK  
CEILING SUSPENDED  
PCH-3GAK  
PCH-4GAK  
PCH-4GAK  
PCH-5GAK  
PCH-6GAK  
Models  
Function  
Capacity  
Total input  
Cooling  
7,600  
3.28  
Heating  
8,500  
3.07  
Cooling  
10,000  
3.36  
Heating  
10,450  
3.35  
Cooling  
12,400  
4.45  
Heating  
13,900  
4.40  
Cooling  
14,500  
4.97  
Heating  
15,000  
4.82  
W
kW  
COP  
W/W  
2.32  
2.77  
2.98  
3.12  
2.79  
3.16  
2.92  
3.11  
Model name  
External finish  
Power supply  
Airflow (Lo-Hi)  
PCH-3GAK  
PCH-5GAK  
PCH-6GAK  
Munsell 0.70Y 8.59/0.97  
Single phase, 50Hz, 240V  
l/s  
Pa (mmAq)  
dB  
233 – 300  
37 – 43  
333 – 417  
40 – 45  
450 – 567  
1,620  
External static pressure  
Indoor unit  
0 (direct blow)  
680  
Sound pressure level (Lo-Hi)  
41 – 46  
42 – 48  
W mm  
D mm  
H mm  
kg  
1,310  
Dimensions  
210  
34  
270  
43  
Weight  
37  
45  
PUH-3YKA  
PUH-4YKSA  
PUH-5YKSA  
PUH-6YKSA  
Model name  
External finish  
Power supply  
Munsell 5Y 7/1  
3-ph., 50Hz, 415V (4 wires)  
Refrigerant (R-22) control  
Compressor output  
Capillary tube  
kW  
2.4  
2.7  
3.5  
4.0  
Internal thermostat, HP switch/thermal  
relay, thermal switch, HP switch,  
anti-phase protector  
thermal relay, thermal switch,  
HP switch, anti-phase protector  
Internal thermostat, thermal switch, HP switch, anti- phase protector  
1,667  
Protection devices  
Outdoor unit  
Airflow  
l/s  
W
833  
1,584  
38  
Crankcase heater  
Sound pressure level  
Sound power level  
dB  
52  
66  
54  
69  
55  
70  
56  
71  
dB  
W mm  
D mm  
H mm  
kg  
870  
295 + 24  
970  
Dimensions  
Weight  
345 +24  
850  
75  
1,258  
114  
94  
117  
PEH-EAK  
CEILING CONCEALED  
Models  
PEH-2.5EAK  
PEH-3EAK  
PEH-4EAK  
Cooling Heating  
9,700  
PEH-5EAK  
PEH-6EAK  
Function  
Cooling  
6,700  
2.90  
Heating  
6,800  
2.71  
Cooling  
Heating  
8,300  
3.33  
Cooling  
12,400  
4.86  
Heating  
13,000  
4.81  
Cooling  
Heating  
17,400  
5.66  
Capacity  
W
kW  
8,000  
3.47  
2.31  
10,400  
3.63  
15,200  
5.81  
Total input  
COP  
3.64  
2.66  
W/W  
2.31  
2.51  
2.49  
2.87  
2.55  
2.70  
2.62  
3.07  
Model name  
External finish  
Power supply  
PEH-2.5EAK  
PEH-3EAK  
PEH-4EAK  
PEH-5EAK  
PEH-6EAK  
Galvanized sheets  
Single phase, 50Hz, 240V  
450 – 567  
Airflow (Lo-Hi)  
l/s  
Pa (mmAq)  
dB  
367 – 450  
567 – 700  
1,255  
800 – 1,000  
External static pressure  
127 (12.7) at Hi-notch  
Indoor unit  
Sound pressure level (Lo-Hi)  
Dimensions  
52 – 55  
785  
54 – 58  
51 – 55  
1,415  
W mm  
D mm  
H mm  
kg  
1,055  
690  
428  
Weight  
45  
46  
58  
72  
73  
Model name  
External finish  
PUH-2.5AKA  
PUH-3VKA / PUH-3YKA  
PUH-4YKSA  
Munsell 5Y 7/1  
PUH-5YKSA  
PUH-6YKSA  
Single ph., 50Hz, 240V/  
3-ph., 50Hz, 415V (4 wires)  
Power supply  
Single ph., 50Hz, 240V  
2.0  
3-ph., 50Hz, 415V (4 wires)  
Refrigerant (R-22) control  
Compressor output  
Capillary tube  
2.7  
kW  
2.2 / 2.4  
3.5  
4.0  
Intermal thermostat, HP  
switch/thermal relay, thermal  
switch, HP switch, anti-  
phase protector  
Thermal relay, thermal  
switch, HP switch, anti-  
phase protector  
Internal thermostat,  
thermal switch,  
HP switch, anti-phase protector  
Internal thermostat,  
HP switch  
Protection devices  
Outdoor unit  
Airflow  
l/s  
W
833  
1,584  
1,667  
Crankcase heater  
Sound pressure level  
Sound power level  
38  
54  
69  
dB  
52  
66  
55  
70  
56  
71  
dB  
W mm  
D mm  
H mm  
kg  
870  
970  
Dimensions  
Weight  
295 + 24  
345 +24  
850  
1,258  
114  
68  
75  
94  
117  
12  
GENERAL SPECIFICACIONS FOR ALL MODELS  
Notes for All Specifications  
Rating conditions: Cooling - Indoor 27ºCDB, 19ºCWB; Outdoor 35ºCDB  
Heating - Indoor 20ºCDB  
Data based on indicated voltage Indoor unit : 1-ph, 240V, 50Hz  
Outdoor unit: 1-ph, 240V, 50Hz/3-ph, 415V, 50Hz  
; Outdoor 7ºCDB,6ºCWB  
Refrigerant piping length (one-way): 5m (16ft)  
Refrigerant charge is suitable for 5m piping length.  
Guaranteed Operating Range  
Limits  
Indoors  
Outdoors  
-5ºC DB  
46ºC DB  
Lower  
Upper  
Lower  
Upper  
21ºC DB, 15.5ºC WB  
35ºC DB, 22.5ºC WB  
20ºC DB  
Cooling  
Heating  
-8.5ºC DB, -9.5ºC WB  
21ºC DB, 15.5ºC WB  
27ºC DB  
Refrigerant Piping  
Models  
Between indoor & outdoor units  
Max. piping length, m  
Pipe size O.D., mm  
Liquid  
Gas  
Max. height difference, m  
Max. number of bends  
PLH-3AAK, PKH-3FAK,  
50  
50  
50  
15  
Ø 9.52  
Ø 9.52  
Ø 15.88  
PCH-3GAK, PEH-2.5EAK, PEH-3EAK  
PKH-4FAK PLH-4/5/6AAK,  
50  
15  
Ø 19.05  
PCH-4/5/6GAK, PEH-4/5/6EAK  
Optional Refrigerant Pipes  
Part number  
Pipe length  
5m (16ft)  
7m (23ft)  
10m (33ft)  
15m (49ft)  
Connection method  
Pipe size OD, mm (ft)  
Applicable models  
PAC-05FFS-E  
PAC-SC51PI-E  
PAC-SC52PI-E  
PAC-SC53PI-E  
PAC-SC54PI-E  
Flared-flared  
PAC-07FFS-E  
PAC-10FFS-E  
PAC-15FFS-E  
Flared-flared  
Liquid: Ø 9.52 (3/8) Gas: Ø 15.88 (5/8)  
PKH-3FAK, PLH-3AAK, PCH-3GAK, PEH-2.5EAK, PEH-3EAK  
Liquid: Ø 9.52 (3/8) Gas: Ø 19.05 (3/4)  
PKH-4FAK, PLH-4/5/6AAK, PCH-4/5/6GAK, PEH-4/5/6EAK  
Additional Refrigerant Charge [R-22: kg]  
Piping length (one-way)  
Models  
5m  
0
10m  
15m  
20m  
25m  
30m  
35m  
0.2  
0.2  
0.3  
0.3  
0.3  
40m  
0.2  
0.2  
0.3  
0.3  
0.3  
45m  
0.5  
0.5  
0.6  
0.6  
0.6  
50m  
PUH-2.5AKA  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.5  
0.5  
0.6  
0.6  
0.6  
PUH-3VKA/PUH-3YKA  
PUH-4YKSA  
0
0
PUH-5YKSA  
0
PUH-6YKSA  
0
Cooling Capacity Correction Factors  
Models  
Correction factors (Cooling / Heating)  
One-way piping length, m  
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
PEH-2.5EAK  
1.00/1.00  
0.989/1.00  
0.980/1.00  
0.960/1.00  
0.950/1.00  
0.970/1.00  
0 .9 4 0 / 0 .9 9 8  
0 .9 3 0 / 0 .9 9 5  
0 .9 2 0 / 0 .9 9 3  
0 .9 1 0 / 0 .9 9 0  
PKH-3FAK, PCH-3GAK,  
PLH-3AAK, PEH-3EAK  
PKH-4FAK PCH-4GAK,  
PLH-4AAK, PEH-4EAK  
PCH-5GAK PLH-5AAK,  
PEH-5EAK  
PCH-6GAK, PLH-6AAK  
PEH-6EAK  
1.00/1.00  
1.00/1.00  
1.00/1.00  
1.00/1.00  
0.981/1.00  
0.989/1.00  
0.981/1.00  
0.975/1.00  
0.968/1.00  
0.980/1.00  
0.968/1.00  
0.955/1.00  
0.952/1.00  
0.970/1.00  
0.952/1.00  
0.935/1.00  
0.940/1.00  
0.960/1.00  
0.940/1.00  
0.918/1.00  
0.925/1.00  
0.950/1.00  
0.925/1.00  
0.900/1.00  
0 .9 1 3 / 0 .9 9 8  
0 .9 4 0 / 0 .9 9 8  
0 .9 1 3 / 0 .9 9 8  
0 .8 8 4 / 0 .9 9 8  
0 .9 0 0 / 0 .9 9 5  
0 .8 8 6 / 0 .9 9 3  
0 .9 2 0 / 0 .9 9 3  
0 .8 8 6 / 0 .9 9 3  
0 .8 5 5 / 0 .9 9 3  
0 .8 7 4 / 0 .9 9 0  
0 .9 3 0 / 0 .9 9 5  
0 .9 0 0 / 0 .9 9 5  
0 .8 6 9 / 0 .9 9 5  
0 .9 1 0 / 0 .9 9 0  
0 .8 7 4 / 0 .9 9 0  
0 .8 4 0 / 0 .9 9 0  
Main Optional Parts  
Model  
Description  
Applicable models  
New A/K control  
MAC-397IF-E  
PAC-SE55RA-E  
PAC-725AD  
MA & Control Terminal Interface  
Timer Adapter  
New A/K control  
New A/K control  
New A/K control  
PUH-2.5~4  
PUH-5/6  
Multiple Remote Controller Adapter (10 sets)  
Remote Sensor  
PAC-SE41TS-E  
PAC-SA46DS-E  
PAC-SA47DS-E  
PAC-292SG-D  
SDD-50S-E  
Drain Socket  
Drain Socket  
Air Outlet Guide  
PUH-2.5~6  
PUH-5/6  
Distribution Pipe for Twin Use  
Multi-Function Casement  
High Efficiency Filter Element  
Air Outlet Shutter Plate  
Drain Lift-Up Mechanism  
Drain Lift-Up Mechanism  
High Efficiency Filter  
PAC-SG03TM-E  
PAC-SG01KF  
PAC-SG06SP-E  
PAC-SE85DMA-E  
PAC-SE86DMA-E  
PAC-SE81KF-E  
PAC-SE82KF-E  
PAR-SL99B-E  
PAR-SL97A-E  
PLH series  
PLH series  
PLH series  
PCH-3  
PCH-4~6  
PCH-3/4  
High Efficiency Filter  
PCH-5/6  
Wireless Remote Controller  
Wireless Remote Controller  
PCH series  
PLH series  
13  
Outdoor Unit Installation Location  
• When installing a single outdoor unit:  
Obstacle at rear only  
Service space  
Top obstacles  
Obstacles at the right, left  
and rear  
Obstacles at the front and  
rear only  
Obstacle at the front and  
rear only  
PUH-2.5, 3  
10mm or more  
Obstruction width: 1.5 times the width of  
outdoor unit or smaller  
Obstruction height: Unit height or lower  
Air outlet guide  
500mm or more  
100mm or more  
3000mm or more  
100mm or more  
PUH-4,5,6  
10mm or more  
PUH-2.5, 3  
PUH-4,5,6  
A
B
C
D
E
F
G
H
I
J
100mm or more  
10mm or more  
500mm or more  
500mm or more  
Service space  
100mm or more  
500mm or more  
10mm or more  
200mm or more  
150mm or more  
10mm or more  
500mm or more  
500mm or more  
K
L
M
N
O
P
500mm or more  
150mm or more  
3800mm or more  
150mm or more  
150mm or more  
500mm or more  
10mm or more  
300mm or more  
Q
• When installing many outdoor units:  
Face-to-face arrangement  
(with air outlet guides)  
Face-to-face arrangement  
(without air outlet guides)  
Parallel arrangement  
(with air outlet guides)  
Parallel arrangement  
(without air outlet guides)  
PUH-2.5, 3  
PUH-4,5,6  
A
B
C
D
E
F
G
H
I
200mm or more  
500mm or more  
200mm or more  
1200mm or more  
1000mm or more  
2000mm or more  
100mm or more  
10mm or more  
300mm or more  
500mm or more  
300mm or more  
1500mm or more  
1500mm or more  
2500mm or more  
150mm or more  
10mm or more  
Side-by-side arrangement  
200mm or more  
300mm or more  
Up to 10 units (When the optional air outlet  
guides are used, no more than five units should  
be arranged side by side.)  
J
K
1000mm or more  
1000mm or more  
Precautions/recommendations concerning the installation and operation of Mitsubishi Electric Mr. Slim air conditioners.  
When used in rooms with high ceilings, it is recommended that a ceiling fan or  
circulator be installed to improve air circulation and temperature variations within  
the room.  
Avoid exposure to high-frequency waves as this may cause the microprocessor  
to malfunction.  
Rated noise levels were derived from tests in an anechoic test room. Noise  
levels may therefore be greater depending on the surroundings, application,  
and/or manner of installation.  
The remote-control circuits under microprocessor control remain on at all  
times whether the air conditioner is or is not in operation. For more economical  
operation, it is recommended that the main power switch be turned off when the  
air conditioner(s) is not used for long periods.  
Avoid using air conditioners in rooms with high humidity because excessive  
condensation will occur as the air cools.  
Avoid using air conditioning units in areas where they are exposed to oil or oily  
smoke (cooking areas or machine shops). Oil which adheres to the heat  
exchangers will cause reduced efficiency, generate mist and may damage plastic  
components.  
To avoid fire hazards, do not use air conditioners in areas where inflammable  
gases are present.  
Odours for buildings, cosmetics, perspiration, cigarette smoke, etc., may  
accumulate in the heat exchanger and emanate from the air conditioner. This is  
not indicative of mechanical trouble.  
14  
Mitsubishi Electric Shizuoka Works acquired ISO  
9001 certification under Series 9000 of the  
International Standard Organization (ISO) based on  
a review of Quality warranties for the production of  
refrigeration and air conditioning equipment.  
Mitsubishi Electric Shizuoka Works acquired envi-  
ronmental management system standard ISO  
14001 certification.  
NATIONAL  
ACCREDITATION  
OF CERTIFICATION  
BOOIS  
ISO 9001  
Certificate Number 49385  
Certificate Number EC97J1132  
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN  
MITSUBISHI ELECTRIC AUSTRALIA PTY LTD.  
BLACK DIAMOND TECHNOLOGIES  
www.mitsubishielectric.com.au (Incorporated in New South Wales)ABN 58 001 215 792  
New South Wales: Victoria/Tasmania:  
Queensland  
Unit 12,  
Far North  
South Australia/  
Northern Territory: Unit 5,  
77 Port Road,  
Hindmarsh 5007  
Ph: (08) 8340 2000  
Western Australia:  
Wellington:  
Auckland:  
Unit 1,  
4 Walls Road  
Po Box 12-726,  
Penrose  
Christchurch:  
Suite 2, Level 1,  
37 Mandeville Street  
Po Box 1604  
348 Victoria Road,  
Rydalmere 2116  
Ph: (02) 9684 7555  
Unit 4,  
Queensland:  
Capricorn Air,  
13 Mackley st,  
Garbutt 4814  
Ph: (07) 4775 5222  
1 Parliament Street  
Po Box 30-772  
Lower Hutt  
Wellington  
Ph: (04) 560 9147  
Fax: (04) 560 9133  
303 Burwood Highway, 469 Nudgee Rd.,  
East Burwood 3151  
329 Collier Road,  
Bassendean 6054  
Ph: (08) 9377 3400  
Hendra 4011  
Ph: (07) 3623 2000  
Fax: (02) 9898 1043 Ph: (03) 9262 9855  
Ph: (03) 341 2837  
Fax: (08) 8340 0555 Fax: (08) 9377 3499  
Ph: (09) 526 9347 Fax: (03) 341 2838  
Fax: (09) 526 9369  
Fax: (03) 9262 9844  
Fax: (07) 3630 1888  
Fax: (07) 4775 5305  
Revised publication, effective August 2006  
Superseding publication of L-179-0-C3085-E November 2005  
Specifications subject to change without notice.  
L-179-0-C3085-F SI-0608 Printed in Japan(NLP)  

Mitsubishi Electronics Msz Ga35va User Manual
Painless Performance 60505 User Manual
Philips Lr1pb2c User Manual
Royal Sovereign Arp 5012x User Manual
Samsung Avmbh032ca0 User Manual
Samsung Clx 6250fx User Manual
Savin Ld232c User Manual
Sharp Af Q60rx User Manual
Sharp Af R140cx User Manual
Whirlpool X05002x0 User Manual