SAFETY NOTICE................................................................. 2-3  
LIST OF MATERIALS.......................................................  
4
INSTALLATION  
Ducting Calculation Sheet.......................................  
Mounting Height & Clearance................................  
Ducting Options...........................................................  
Specifications ...............................................................  
Electrical.........................................................................  
5
6
7
8
9
Mounting the Range Hood...................................... 10  
Single and Dual Internal Blowers......................... 11  
CBI-600B Horizontal Ducting Conversion........ 12-13  
External Blower Preparation .................................. 14  
FEATURES & CONTROLS  
Touch Controls & Features..................................... 15  
MAINTENANCE  
Cleaning and Filter Removal.................................. 16  
Lights................................................................................ 17  
TROUBLESHOOTING................................................................ 18  
LIST OF PARTS AND ACCESSORIES.............................. 19  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
READ AND SAVE THESE INSTRUCTIONS  
WARNING  
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.  
WARNING  
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.  
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.  
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service  
panel.  
CAUTION  
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning  
agents or detergents. Suitable for use in household cooking area.  
WARNING  
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:  
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly  
on low or medium settings.  
b. Always turn hood ON when cooking at high heat or when flaming food  
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.  
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.  
e. Keep fan, filters and grease laden surfaces clean.  
f. Use high setting on hood only when necessary.  
g. Don’t leave hood unattended when cooking.  
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.  
WARNING  
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:  
a. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.  
If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  
b. NEVER PICK UP A FLAMING PAN – You may be burned.  
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.  
d. Use an extinguisher ONLY if:  
1. You know you have a Class ABC extinguisher, and you already know how to operate it.  
2. The fire is small and contained in the area where it started.  
3. The fire department is being called.  
4. You can fight the fire with your back to an exit  
WARNING  
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
a. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards.  
Including fire-rated construction.  
b. Sufficient air is needed for power combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent  
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National  
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and  
the local code authorities.  
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.  
d. Ducted fans must always vent to the outdoors.  
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI  
(Ground Fault Interrupter protected branch circuit).  
g. NEVER place a switch where it can be reached from a tub or shower.  
h. Make sure the power is off before installing, wiring or maintenancing.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.  
CAUTION  
To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,  
attics, crawl spaces or garages.  
OPERATION  
Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers  
and loose clothing.  
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,  
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to  
negligence and the warranty of the unit automatically expires due to improper maintenance.  
ELECTRICAL REQUIREMENTS  
Important:  
Observe all governing codes and ordinances.  
It is the customer’s responsibility:  
-
-
To contact a qualified electrical installer.  
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70  
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and  
all local codes and ordinances.  
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the  
ground path is adequate.  
Do not ground to a gas pipe.  
Check with a qualified electrician if you are not sure the range hood is properly grounded.  
Do not have a fuse in the neutral or ground circuit.  
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269  
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575  
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit  
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to  
Electrical Diagram on product.  
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase  
and install appropriate connector if necessary.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODELS: AK7500ASX, AK7536ASX, AK7548ASX  
PARTS SUPPLIED  
1 - Hood  
2 - Baffle filters AK7500ASX, 3 - AK7536ASX, 4 - AK7548ASX  
2 - Halogen light bulbs 3 - AK7548ASX (pre-installed)  
1 - 10” round transition adapter (for dual internal and external blowers)  
1 - External blower wiring (for external blower)  
1 - Rectangular starting collar (for single blower horizontal ducting)  
1 - 6” round to rectangular transition (for single blower horizontal ducting)  
2 - Blower brackets (for single blower horizontal ducting)  
1 - Hardware package  
HARDWARE PACKAGE CONTENTS  
Suction Cup (1)  
M4 x 2” (4)  
M4 x 1-1/2” (4)  
M4 x 1” (4)  
M4 x 8 (8)  
M3.5 x 8 (7)  
10 x 3/16” (6)  
Wire Caps (3)  
M4 x 16 (4)  
PARTS NOT SUPPLIED  
- Wood Board to hang hood ( W x D x H)  
AK7500ASX - 28” x 3/4” x 4”  
- Ducting, conduit and all installation tools  
- Cable connector (if required by local codes)  
- Single Blower Kit (CBI-600A)  
- Dual Blower Kit (PBI-1100)  
AK7536ASX - 34” x 3/4” x 4”  
AK7548ASX - 46” x 3/4” x 4”  
- External Blower Kit (CBE-1000)  
- Heat Lamp Accessory  
- Back Splash Accessory  
- Duct Cover Accessory  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Equivalent number  
length x used  
Equivalent number  
length x used  
Duct pieces  
Duct pieces  
=
To t a l  
=
To t a l  
Ft.  
Ft.  
Ft.  
Ft.  
3-1/ 4” x 10” 1 Ft.  
x (  
x (  
x (  
x (  
)
)
)
)
=
=
=
=
Ft.  
6” Round  
wall cap  
30 Ft.  
x (  
)
=
Rect.,  
straight  
with damper  
6” Round,  
straight  
1 Ft.  
Ft.  
Ft.  
6” Round,  
roof cap  
30 Ft.  
1 Ft.  
x (  
x (  
)
)
=
=
7”-10” Round, 1 Ft.  
straight  
6” roundto  
3-1/ 4” x 10”  
rect.  
transition  
3-1/ 4” x 10” 15 Ft.  
Ft.  
6” roundto  
3-1/ 4” x 10”  
rect.  
16 Ft.  
x (  
)
=
0
Rect.90  
elbow  
transition  
0
Ft.  
3-1/ 4” x 10” 9 Ft.  
x (  
)
=
90 elbow  
0
Rect.45  
elbow  
Ft.  
Ft.  
7” - 10”  
Round,  
15 Ft.  
9 Ft.  
x (  
x (  
)
)
=
=
0
90 elbow  
Ft.  
Ft.  
3-1/ 4” x 10” 24 Ft.  
x (  
x (  
)
)
=
=
0
Rect.90  
7” - 10”  
Round,  
flat elbow  
0
45 elbow  
3-1/ 4” x 10” 30 Ft.  
Rect.  
wall cap  
with damper  
Ft.  
Ft.  
Ft.  
7” - 10”  
30 Ft.  
30 Ft.  
8 Ft.  
x (  
x (  
x (  
)
)
)
=
=
=
Round  
wall cap  
with damper  
Ft.  
Ft.  
3-1/ 4” x 10” 5 Ft.  
Rect.to  
6” round  
transition  
x (  
x (  
)
)
=
=
7” - 10”  
Round,  
roof cap  
7” roundto  
3 1/ 4” x 10”  
rect.  
3-1/ 4” x 10” 20 Ft.  
Rect.to  
6” round  
transition  
transition  
0
90 elbow  
Ft.  
7” roundto  
3-1/ 4” x 10”  
rect.  
23 Ft.  
x (  
)
=
Ft.  
6” Round,  
15 Ft.  
9 Ft.  
x (  
x (  
)
)
=
=
0
90 elbow  
transition  
0
90 elbow  
Ft.  
Ft.  
6” Round,  
Subtotal column2 =  
Subtotal column1 =  
Ft.  
Ft.  
Ft.  
0
45 elbow  
Subtotal column1 =  
Total ductwork  
=
Maximum Duct Length: For satisfactory air movement,  
the total duct length should not exceed 100 equivalent feet.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Minimum mount height between range top to hood  
bottom should be no less than 26”.  
Maximum mount height should be no higher than  
36”.  
12"  
It is important to install the hood at the proper  
mounting height. Hoods mounted too low could  
result in heat damage and fire hazard; while hoods  
mounted too high will be hard to reach and will  
lose its performance and efficiency.  
18"  
If available, also refer range manufacturer’s height  
clearance requirements and recommended hood  
mounting height above range.  
Min 26" - Max 36"  
*Min 92”  
*Max 102"  
Vertical Ducting:  
6” round minimum (singe blower)  
10” round minimum (dual and external blower)  
36"  
Horizontal Ducting:  
3-1/4”x10” minimum (single blower)  
No horizontal option available for dual or  
external blower  
*with 12" duct cover  
DUCTING  
A minimum of 6” round or 3-1/4” x 10” rectangular  
duct must be used to maintain maximum air flow  
efficiency for single blower and 10” round duct for  
dual and external blower.  
Always use rigid type metal ducts only. Flexible  
ducts could restrict air flow by up to 50%.  
Also use calculation (on page 5) to compute total  
available duct run when using elbows, transitions  
and caps.  
ALWAYS, when possible, reduce the number or  
transitions and turns. If long duct run is required,  
increase duct size.  
If turns or transitions are required; install as far  
away from hood duct output and as far apart,  
between the two as possible.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING FIRE HAZARD  
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.  
All exhaust must be ducted to the outside.  
Use metal ductwork only.  
Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.  
Some Ducting Options  
Side wall cap  
w/ gravity damper  
Side wall cap  
w/ gravity damper  
Soffit or crawl space  
Roof Pitch w/  
Flashing & Cap  
Rear Ducting  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
13 3/16”  
12”  
2 1/16”  
*10 ”  
2 11/16”  
ext elec  
blwr k/o  
k/o  
C
L
29 15/16” (30”)  
35 15/16” (36”)  
47 15/16” (48”)  
24”  
*10” transition used with dual and  
external blowers.  
top  
side  
ø 9 15/16”  
9 15/16”  
elec  
k/o  
3/8  
14  
0
1
3/16”  
3 7/16”  
C
L
24” (30”)  
30” (36”)  
42” (48”)  
back  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL  
WARNING  
All Electrical work must by performed by qualified electrician or person with similar technical know  
how and background.  
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use  
extension cord or adapter plug with this appliance.  
Follow national electrical codes or prevailing local codes and ordinances.  
Electrical Supply:  
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded  
branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/  
ground. Please also refer Electrical Diagram labeled on product.  
Cable Lock:  
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements  
and codes, purchase and install appropriate connector if necessary.  
Cable Lock  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
!
CAUTION: At least two installers are  
required due to the weight and size of the  
hood.  
C/L  
1. Measure distance from range top to hood bottom (26” min) Level  
and mark line A.  
2. Plum and mark center line.  
B
A
wood board  
4”  
3. Mark mounting height line B. (12 3/8” from line A)  
12 3/8”  
(This is the top of the board used to hang the hood)  
4. Mark center line of wood board and align top of board with line B.  
Secure wood board to studs using (4) M4 wood screws. Wood Board  
Dimensions: (W x D x H)  
AK7500ASX - 28” x 3/4” x 4”  
min  
26”  
AK7536ASX - 34” x 3/4” x 4”  
AK7548ASX - 46” x 3/4” x 4”  
5. If horizontally ducting hood refer to hood specifications on page 8 for  
cut-out dimensions.  
6. *Hang hood on wood board and secure using (4) M4 x 16 screws.  
7. Install blower(s). Turn to page 11 for blower installation  
instructions.  
8. Install electrical.  
9. Install duct work and duct tape.  
10. Power up hood and check for leaks around duct tape.  
C/L  
11. Install optional accessories: duct cover (fig. 2-C), back splash (fig. 2-  
D), and/or heat lamp kit (fig. 2-E). (sold separately) For more detailed  
instructions refer to manual included with each accessory.  
fig. 1  
12. Reinstall baffle filters.  
NOTE: If installing a back splash do not install screws at bottom of  
hood yet. There is a lip on the back splash that needs to be inserted  
behind the hood first.  
C
fig. 2 - C  
fig. 2 - D  
D
fig. 2 - E  
NUT  
SCREW  
E
fig. 2  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PBI-1100A DUAL INTERNAL BLOWER WILL ACCOMODATE VERTICAL DUCTING ONLY  
Please turn to page 12 for instructions on installing CBI-600B in horizontal ducting mode.  
2. Connect male end of blower wire to female plug  
in the hood. (plug is located inside the hood  
behind the control panel)  
1. Position blower plate over bracket on inside  
back of hood and pivot up. Secure plate to hood  
with (2) 10x3/16” screws. (blower pictured is a  
PBI-1100A)  
3. Single Blower – Connect 6” round duct work to  
blower collar.  
Dual Blower – Place 10” round adapter on top of  
hood and secure with (4) M4x8 screws.  
Connect 10” round duct work to 10” round  
adapter.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HORIZONTAL DUCTING IS ONLY AVAILABLE IF USING THE  
CBI-600B SINGLE INTERNAL BLOWER.  
1. Unscrew (4) screws holding blower to plate and  
remove blower.  
2. Cover round blower opening on blower plate  
with 6” round metal cap included with the  
CBI-600B. Secure with (3) 3.5x8 screws.  
3. Follow instructions on previous page and install  
blower plate into hood.  
4. On the back of the hood, remove the (6) screws  
holding the rectangular cap to the hood.  
5. Place round to rectangular transition adapter  
inside hood.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Attach 6” round to rectangular transition adapter  
to hood with (4) M4x8 screws.  
7. Attach blower brackets to blower with  
(4) 10x3/16” screws. (2) screws for each  
bracket.  
8. Place blower into round end of 6” round  
transition adapter. Attach brackets on blower to  
blower plate with (4) 3.5x8 screws. (2) screws  
for each bracket.  
9. Attach rectangular starting collar to hood using  
the (6) screws removed from the rectangular  
cap in step 4.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Install threaded end of external blower wiring  
1. Place 10” round adapter on top of hood and  
secure with (4) M4x8 screws. Connect 10”  
round duct work to 10” round adapter.  
through external blower wiring knock out  
located inside the hood.  
3. Place cap over threaded end of external blower  
wiring and secure by turning clockwise.  
4. Connect 6 pin male connector from external  
blower wiring to 6 pin female connector on  
control board wire inside hood. Secure green  
ground wire from external blower wiring to  
ground screw on hood.  
CBE-1000: WIRING DIAGRAM  
White (common)  
External Blower  
Wiring Box  
(hood)  
Black (high)  
Blue (med)  
Red (low)  
Junction Box  
(CBE-1000)  
Green (ground)  
NOTE: For instructions on mounting the external blower, please refer to the CBE-1000 manual included  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Lights On/Dim/Off  
4
5 Display (Speed level, Delay Off Indicator)  
3 5 Min Delay Off  
1 Blower On/Off  
Adjust 3 Speed Levels  
2
1
2
3
Blower On/Off  
By pressing  
, the blower is switched On and Off. When switched on, the blower turns on at the same  
speed it was switched off at. When switched off the entire hood powers off, including the lights.  
Speed Selection  
The 3 speed levels are selected by pressing  
display indicates speed level selected. Pressing  
to decrease and  
to increase speed level. The  
when the hood is off will also turn it on.  
Delay Off  
This is used for programmed shut down of blower and lights 5 minutes after the function is  
activated. Press once, a dot displays in the lower right hand side of display indicating  
the function is on. The hood will change to speed 1 and shut down after 5 minutes.  
4 Lights On/Dim/Off  
Switch lights On by pressing  
once, again to dim and again to switch Off.  
Display  
5
Displays blower speed level and delay off status.  
Manual On/Off  
Located behind the right side light panel is a manual power on/off toggle switch. This switch is used  
to manually cut power to the hood to perform a hard reset for troubleshooting purposes. Toggle  
between I (on) or 0 (off).  
Heat Lamps On/Off  
Located on the right and left side light panel are manual power on/off toggle switches. These  
switches are used to turn the heat lamps on/off. Toggle between I (on) or 0 (off).  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SURFACE MAINTENANCE:  
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent,  
or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine  
bleach or orange cleaners.  
For heavier soil use liquid degreaser.  
After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless  
luster and grain. Always scrub lightly using a micro fiber or clean cotton cloth and with grain.  
Stainless Steel Baffle Filters  
The stainless steel baffle filters are intended to trap residue and grease from cooking. Although the filters  
should never need replacing, they are required to be cleaned every 30 days or more often depending on  
cooking habits.  
Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re-install before  
using hood.  
Removing Baffle Filters  
1. Push filter toward back of range hood using handles.  
2. Pivot front of filter downward.  
3. Remove filter by pulling away from hood.  
Replacing Baffle Filters  
1
Hood Model:  
AK7500ASX  
AK7536ASX  
AK7548ASX  
Part No.  
Qty. to Order.  
50210004  
50210004  
50210004  
2
3
4
2
3
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACING LIGHT BULBS  
CAUTION: Light bulb becomes extremely hot when turned on.  
DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.  
Make sure all power is turned off and bulbs are not hot.  
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and  
falls out.  
If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approximately the  
diameter of the bulb or use a rubber/latex glove and turn counter clockwise.  
Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen.  
For Zephyr part numbers please turn to page 20 of the manual.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING PROCEDURES FOR TEMPEST I AND TEMPEST II  
Issue  
Cause  
What to do  
After installation, 1. The power source is not turned ON.  
the unit doesn’t  
1. Make sure the circuit breaker and the unit’s  
power is ON.  
work.  
2. The power line and the cable locking connector  
2. Check the power connection with the unit is  
connected properly.  
is not connecting properly.  
3. The switch board and control board wirings are  
disconnected.  
3. Make sure the wirings between the switch  
board and control board are connected  
properly.  
4. The wires on control board are loose.  
4. Make sure the wires on the control board are  
connected properly.  
5. The switch board or control board is defective.  
5. Change the switch board or control board.  
1. Change the motor.  
Light works,  
but motor is not  
turning.  
1. The motor is defective, possible seized.  
2. The thermally protected system detects if the  
motor is too hot to operate and shuts the motor  
down.  
2. The motor will function properly after the  
thermally protected system cool down.  
3. Damaged capacitor.  
3. Change the capacitor.  
4. The motor wire is not connected.  
4. Make sure the motor wire is plugged into the  
molex connector.  
The unit is  
vibrating.  
1. The motor is not secure in place.  
2. Damaged blower wheel.  
1. Tighten the motor in place.  
2. Change the blower.  
3. The hood is not secured in place.  
1. Defective halogen bulb.  
3. Check the installation of the hood.  
1. Change the halogen bulb.  
2. Tighten the light bulb.  
The motor is  
working, but the  
lights are not.  
2. The light bulb is loose.  
3. The wires on the control board are loose.  
3. Make sure the wires on control board are  
connected properly.  
The hood is  
not venting out  
properly.  
1. The hood might be hanging to high from the  
cook top.  
1. Adjust the distance between the cook top and  
the bottom of the hood within 26” and 36”  
range.  
2. The wind from the opened windows or opened  
doors in the surrounding area are affecting the  
ventilation of the hood.  
2. Close all the windows and doors to eliminate  
the outside wind flow.  
3. Blockage in the duct opening or duct work.  
3. Remove all the blocking from the duct work or  
duct opening.  
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.  
5. Using the wrong size of ducting.  
5. Change the ducting to correct size.  
1. Make sure the heat lamp power is ON.  
2. Change the heat lamp bulb.  
3. Tighten the heat lamp bulb.  
1. Change the metal filter.  
Heat lamp is not 1. Toggle switch is not in the on position.  
working.  
2. Heat lamp bulb is defective.  
3. Heat lamp bulb is loose.  
Metal filter is  
vibrating.  
1. Metal filter is loose.  
2. Spring clip is broken.  
2. Change the spring clip.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESCRIPTION  
PART #  
Replacement Parts  
Light Bulb MR16 (GU10) 35W (each)  
Baffle Filter (each)  
Z0B-0023  
50210004  
Optional Accessories  
Single Internal Blower  
Dual Internal Blower  
External Blower  
CBI-600B  
PBI-1100A  
CBE-1000  
AK0700B  
AK0706B  
AK0708B  
AK0710  
Heat Lamp Kit (30”)  
Heat Lamp Kit (36”)  
Heat Lamp Kit (48”)  
Back Splash (30”)  
Back Splash (36”)  
Back Splash (48”)  
12” Duct Cover (30”)  
12” Duct Cover (36”)  
12” Duct Cover (48”)  
AK0716  
AK0718  
AK0720  
AK0726  
AK0728  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STAPLE YOUR RECEIPT HERE  
Proof of the original purchase  
date is needed to obtain  
Limited Warranty  
service under warranty  
TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call:  
1-888-880-8368  
Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein  
as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work-  
manship as follows:  
Ten Year Limited Warranty for Parts: For ten years from the date of your original purchase of the Products, we will  
provide, free of charge, Products or parts to replace those that failed due to manufacturing defects. We may choose, in  
our sole discretion, to repair or replace parts before we elect to replace the Products.  
One Year Limited Warranty for Labor: For one year from the date of your original purchase of the Products, we will  
provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to  
manufacturing defects. After the first year from the date of your original purchase, you are responsible for all labor costs  
associated with this warranty.  
Warranty Exclusions: This warranty covers only repair or replacement, at our option, of defective Products or parts  
and does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and  
service required for the Products and consumable parts such as light bulbs, metal and carbon filters and fuses; (b) any  
Products or parts which have been subject to freight damage, misuse, negligence, accident, faulty installation or installa-  
tion contrary to recommended installation instructions, improper maintenance or repair (other than by us); (c) commer-  
cial use of the Products or use otherwise inconsistent with its intended purpose; (d) natural wear of the finish of the Prod-  
ucts or wear caused by improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner  
products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service trips to your home to teach  
you how to use the Products; or (g) damage to the Products caused by accident, fire, floods or act of God. If you are  
outside our service area, additional charges may apply for shipping costs for warranty repair at our designated service  
locations and for the travel cost to have a service technician come to your home to repair, remove or reinstall the Prod-  
ucts. After the first year from the date of your original purchase, you are also responsible for all labor costs associated  
with this warranty.  
Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE  
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. WE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSE-  
QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF  
THE PRODUCTS. THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF  
ALL OTHER EXPRESS WARRANTIES. WE HEREBY DISCLAIM AND EXCLUDE ALL OTHER EXPRESS WARRAN-  
TIES FOR THE PRODUCTS, AND DISCLAIM AND EXCLUDE ALL WARRANTIES IMPLIED BY LAW, INCLUDING  
THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states or provinces do not  
allow limitations on the duration of an implied warranty or the exclusion or limitation of incidental or consequential dam-  
ages, so the above limitations or exclusions may not apply to you. To the extent that applicable law prohibits the exclu-  
sion of implied warranties, the duration of any applicable implied warranty is limited to the same ten-year period  
described above. Any oral or written description of the Products is for the sole purpose of identifying the Products and  
shall not be construed as an express warranty. Prior to using, implementing or permitting use of the Products, you shall  
determine the suitability of the Products for the intended use, and you shall assume all risk and liability whatsoever in  
connection with such determination. We reserve the right to use functionally equivalent refurbished or reconditioned  
parts or Products as warranty replacements or as part of warranty service. This warranty is not transferable from the  
original purchaser and applies in the United States and Canada.  
To Obtain Service Under Limited Warranty: To qualify for warranty service, you must: (a) notify us at the address or  
telephone number stated below within 60 days of the discovery of the defect; (b) give the model number and part identifi-  
cation number and serial number; and (c) describe the nature of any defect in the Product or part. At the time of the  
request for warranty service, you must present evidence of your proof of purchase and proof of the original purchase  
date. If we determine that the warranty exclusions listed above apply or if you fail to provide the necessary documenta-  
tion to obtain service, you will be responsible for all shipping, travel, labor and other costs related to the services.  
Zephyr Corporation, Service Department, 395 Mendell Street, San Francisco, CA 94124 1-888-880-8368  
APR08.0101  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Westinghouse Computer Monitor LCM 19v5 User Manual
Westinghouse Flat Panel Television SK 26H540S User Manual
Whirlpool Clothes Dryer 3397617 User Manual
Xantech Stereo Amplifier MRAUDIO8X8 User Manual
Xantrex Technology Power Supply 18V 10A User Manual
Xtant Speaker X1244 User Manual
Xtatix MP3 Player Pocket Candy Zent User Manual
Zenoah Brush Cutter T3002 95911 User Manual
Zenoah Trimmer EHT601D User Manual
Zhone Technologies Network Hardware 4929 User Manual