Installation Guide
Wyse® X90L and X90Le Mobile Thin Clients
Flash and Memory Upgrade Kit
Issue: 072310
PN: 883884-22L Rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
iii
Regulatory Compliance for Wyse Products
Basic EMC and Safety Requirements
Wyse appliances are compliant with the regulatory requirements in the regions listed below.
U.S.A. - FCC Part 15 (class B)
Canada - CAN/CSA-C22 No. 60950
Europe - EN 55022 (class B), EN 61000-3-2 (class A), EN 61000-3-3, EN 90650-1:2000+ALL
Canadian DOC Notices
Class A
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out
in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le
Ministère des Communications du Canada.
Class B
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out
in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe B prescrites dans le Réglement sur le brouillage radioélectrique édicté par le
Ministère des Communications du Canada.
Device Power Supply
Use only the external power supply that comes with your mobile thin client. For power and voltage ratings, see
the serial number label or regulatory label on your device. For power adapter replacement, contact your Wyse
Service Representative. For proper replacement compare the labels on both mobile thin client and power
adapter to ensure that their voltages match.
Warning
Use of any other power adapter may damage your mobile thin client or the power adapter. The
damage caused by an improper power adapter is not covered by warranty.
Battery Information
Model Xn0L mobile thin clients contain an internal button cell battery replaceable by Wyse or one of our
Authorized Service Centers. For service, visit http://www.wyse.com/serviceandsupport/service/service.asp.
Warning
There is a risk of explosion if the battery is replaced by an incorrect type. Always dispose of used
batteries according to the instructions accompanying the battery.
Perchlorate Materials - Special Handling May Be Required under California Code of
Regulations, title 22. (Only required within the U.S.A.)
Model Xn0L mobile thin clients contain a user-replaceable battery pack. The battery is designed to work with
mobile thin client. Replace the battery only with a compatible battery purchased from a Wyse Authorized Service
Caution
Misuse of the battery pack may increase the risk of fire of chemical burn. Do not puncture,
incinerate, disassemble, or expose the battery to temperatures above 65°C (149°F). Keep the
battery away from children. Handle damaged or leaking batteries with extreme care. Damaged
batteries may leak and cause personal injury or equipment damage.
Download from Www.Somanuals.com. All Manuals Search And Download.
iv
This page intentionally blank.
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
1
1
1
1
1
2
2
2
3
4
7
Figures 11
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
Contents
This page intentionally blank.
Download from Www.Somanuals.com. All Manuals Search And Download.
Wyse® X90L and X90Le Mobile Thin Clients
Flash and Memory (RAM) Upgrade Kit
Installation Guide
About this Guide
This guide describes how to install the 1-GB, 2-GB, or 4-GB flash and two (2) 1-GB RAM
Upgrade Kit in a Wyse X class mobile thin client. The information in this document is
intended for users of the following mobile thin client products:
•
•
X90L
X90Le
Finding the Information You Need in this Guide
You can use either the Search window or Find toolbar to locate a word, series of words, or
partial word in an active PDF document. For detailed information on using these features,
refer to the Help in your PDF reader.
Wyse Technical Support
Wyse.com home page, go to Support | Knowledge Base | Home tab) or call Customer
Support at 1-800-800-WYSE (toll free in U.S. and Canada). Hours of operation are from
6:00 A.M. to 5:00 P.M. Pacific Time, Monday through Friday.
Wyse Online Community
Wyse maintains an online community where users of our products can seek and
exchange information on user forums. Visit the Wyse Online Community forums at:
Related Online Resources Available at Wyse
Wyse mobile thin client features can be found in the datasheet for your specific model.
click the Wyse Mobile Thin Clients link, click the link for your mobile thin client, and then
click the Download Datasheet link.
Administrator and User documentation for your mobile thin client model are available at:
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Wyse Thin Computing Software is available on the Wyse Web site at:
Getting Started
This section provides information about your flash and RAM kit warranty, kit contents, and
required tools.
Kit Warranty
The warranty on this kit assumes the remaining months of warranty of the mobile thin
client in which it is installed, or for 90 days, whichever is greater. Installation of this kit will
not void the factory warranty, however the user will be responsible for damage due to
improper installation.
Kit Contents
®
®
You kit may included a 1GB, 2-GB, or 4-GB flash module (with Microsoft Windows XP
attach to your mobile thin client.
Figure 1 Flash module types
Figure 2 RAM module types
Figure 3 Upgrade Serial Label
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Required Tools and Materials
You will need the following recommended tools to install the kit:
Small Phillips screwdriver
Plastic alignment tools or equivalent
•
•
Figure 4 Recommended tools
Warning
Flash and RAM modules may be susceptible to damage by Electro-Static
Discharge (ESD). All industry-standard cautions should be followed to avoid
ESD. Before you remove or install a modules, touch any metal part of the
chassis and keep that contact with the chassis during the installation
process.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Installing the Upgrade Kit
To install the 1-GB, 2-GB, or 4-GB flash and one (1) 1-GB RAM Upgrade Kit in an X90L or
X90Le mobile thin client:
Caution
Follow all precautions listed in the Quick-Start Guide that came with your
mobile thin client for disconnecting and reconnecting the mobile thin client.
1. Perform a proper shutdown of the mobile thin client by closing all files and ending your
session, and then press the power button to turn off the mobile thin client.
2. Unplug the power cord and power adapter, and remove any other cables from the
mobile thin client prior to disassembly.
3. Turn the mobile thin client to the back side, and then using your finger nails or the
Figure 5 Unsnapping the switch covers
4. Open the lid of the mobile thin client. Using the plastic alignment tool or your finger
Figure 6 Prying off the switch cover
Download from Www.Somanuals.com. All Manuals Search And Download.
5
5. Using the plastic alignment tool carefully lift up the keyboard (start lifting at the arrow
modules.
Caution
The keyboard is very susceptible to bending so use caution when lifting.
Figure 7 Lifting up keyboard
6. Remove the existing flash module. Locate the flash module and push its retaining clip
out of the socket.
Warning
Flash and RAM modules may be susceptible to damage by Electro-Static
Discharge (ESD). All industry-standard cautions should be followed to avoid
ESD. Before you remove or install a modules, touch any metal part of the
chassis and keep that contact with the chassis during the installation
process.
Figure 8 Removing the flash module
Download from Www.Somanuals.com. All Manuals Search And Download.
6
7. Install the new flash module in the reverse order of removing the old module.
8. To remove the existing RAM module, use your fingers to unlock the two locking clamps
at either side of the module by pushing the clamps in the direction of the arrows shown
Note
Early 1-GB configurations had two (2) 512-MB DIMMs installed. Your mobile
thin client may or may not have a RAM module installed in this location; if it
does, then replace with one (1) 1-GB RAM module.
Figure 9 Removing the RAM module
9. Insert the new RAM module into the connector of the original module, and then press
down on the module so that the two locks will snap in place, securing the module.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Verifying the Mobile Thin Client’s Operation
To verify that the mobile thin client works properly:
1. Reconnect the power cord and power adapter, and then press the power button on the
mobile thin client to apply power.
2. After the mobile thin client restarts, close three windows that have opened on the
screen by following these instructions:
Caution
DO NOT click Ping or this test will fail.
Figure 10 Closing the WinPing window
Figure 11 Closing the DOS window
Download from Www.Somanuals.com. All Manuals Search And Download.
8
c. Click Shutdown in the XPE TEST window to shutdown the mobile thin client, see
Figure 12 Shutting down from the XPE TEST window
3. Press the power button on the mobile thin client for it to restart.
4. From the desktop, click Start | About to open the Client Information window, see
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Figure 13 Client Information
5. Verify that the MAC address and Serial Number matches the serial number and MAC
address on the mobile thin client.
6. Verify that the RAM Configuration is approximately 1471 MB for early mobile thin
clients and 1984 MB for current mobile thin clients.
7. Verify that the Flash Configuration is less than 1024 MB for a 1-GB flash upgrade,
less than 2048 MB for a 2-GB flash upgrade, and less than 4096 MB for the 4-GB
upgrade.
8. Click OK to close the Client Information window.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Attaching the Upgrade Serial Label
The Wyse conversion kit is supplied with a serial label that must be attached to each
mobile thin client.
thin clients to be upgraded.
Caution
Failure to install the label may cause the mobile thin client to receive
incorrect replacement parts if sent in for service.
Figure 14 Attaching the Upgrade Serial Label
2. The mobile thin client is ready for operation and setup by the Administrator.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Guide
Wyse® X90L and X90Le Mobile Thin Clients
Flash and Memory Upgrade Kit
Issue: 072310
Written and published by:
Wyse Technology Inc., July, 2010
®
®
Created using FrameMaker and Acrobat
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Whirlpool Freezer EH151FXRQ00 User Manual
Wilton Lathe 63199 User Manual
Wind Crest Ventilation Hood WCL User Manual
Woods Equipment Lawn Mower Accessory RB750 4 User Manual
Xantrex Technology Power Supply APG HPD User Manual
XO Vision Car Video System XO1915BT User Manual
Zanussi Dishwasher ZSF 6128 User Manual
Zanussi Oven ZMB 32 CT User Manual
Zanussi Washer ZWT 10120 User Manual
Zhone Technologies Network Card Raptor XP 15x User Manual